Loading...
HomeMy WebLinkAboutPP - 11811 44TH AVE S - NEW RESIDENCE - PERMITS AND PLANS11811 44TH AVE S ASSOCIATED PERMITS 18-5-115 D18-0072 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 11811 44th Ave S 334740-0555 Suite Number: Floor: Tenant Name: (new construction) New Tenant? ❑ -Yes E- No Property Owner's Name: Cary Lang Construction Mailing Address: 29815 24th Ave SW CONTACT PERSON -if there are questions about the submittal. Name: Jake Box Company Name: Glacier Fire Protection, LLC Federal Way City WA 98023 State Zip Day Telephone: (307) 251-1701 Mailing Address: PO Box 7980 Bonney Lake akeblacierf .com City E-mail Address: n �g p Fax Number: N/A WA 98391 State Zip Erin Clayton 7544-0817-C Contractor's City of Tukwila 0998044 NICET III number: Business License number: Total number of new/relocated devices or sprinkler heads: 30 Valuation of Project (contractor's bid price): $ 7,800.00 Scope of Work (please provide detailed information): Design & install fire sprinkler system in new constructed 1 family dwelling per NFPA 13D. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O OR A ORIZED A T: Signature: PAID f1/411 23 HIM Date: 5/22/2018 J ke Print Name: Box TU KWDefLR (307) 251-1701 ay P Plan Permit App.doc 8/22/14 TFD FP Form 8 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 41/iceType Sprinklers: of Inspection: Address:/IQ ,/ Suite #: l J "f - -4_4(r_ Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. riCorrections required prior to approval. COMMENTS: fir‘i 4-2. a h.__ Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: �,,t cls— Date: `7/2_ f b. C/ Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 ( INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PIERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: cap (ciqs /.41 /off- Type of Inspection: s ,�� Cw� Rv� "Address.Contact Suite #: fte/L ,e/,G 5. , Person;,.. 5Ke: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Feva6-e,r risr- fe'lb)(6 ak— �-e✓ - c� � � 7?i 747.-k_7 ok_ Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: km cA--- Date: `/ hiJ1 R' Hrs.: j 1 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 SITE PLAN 8 16 32 SCALL 1/16"1'-0" Without Comment As Noted in Red • Per The Attached -etter These plans have been reviewed by The Tukwila Fire Prevents0n Bureau for conformance w th current City standards. ..1::ceptar c ; is subject to rors and omissions v'' Ich do :tot authorize Viol, :tions of adopted standards ono ordn3nces. The respo lsIbllity for the adequacy of- oesigl , > .-.Fi:S totally with t 1e designer. Additions, deletion:: ‘avisions to th se drawings after this date will void th cceptance an ' wH l require a resubrnittai of rofiseo c, Owings fo:-°susequent approval. Final aCcepG nc( i;:; S uofeCI: to flail tes. and Inspection by The Tukwila wire; Prever t?oo IBure3u. Date: X Nyder F .0 ) LA FIRE DEPAR 9 ME f 206-575-4q07 and .S.-11� �i.��� address �•'4 I"� eta i��0. for shut �r c wn or recto ion approval... L._ CPVC PIPE :CPVC PIPE STRAP 0 AFCON MODEL 510 HEX HEAD SELF ;TAPPING SCREW AFCON #905 DOUBLE FASTENER CPVC PIPE STRAP TYPICAL HANGER DETAIL #1 SCALE : N.T.S. .,,PROPERTY LINE GLACIER FIRE PROTEc1ION, LLc TO START AT 1112" BACKFLOW 11811 44TH AVE S NEW 1lir UG' BY OTHERS WOOD LAG SCREW PROPERTY LINE • AFCON #514 HANGER 120V 6" BELL INSTALLED BY OTHERS CPVC SPRINKLER PIPE • WOOD STRUCTURE TYPICAL HANGER DETAIL #2 SCALE: N.T.S. NEW 1" WATER METER_ BY OTHERS ;HANGER APPLICATION NEW CIT CONNECTIONOTHERSi ' ~ BY RESTRAINER APPLICATION HEX HEAD SELF TAPPING SCREW \ CPVC PIPE SINGLE FASTENER CPVC PIPE STRAP TYPICAL HANGER DETAIL #3 SCALE : N.T.S. GENERAL NOTES SCOPE OF WORK 1. THE FIRE PROTECTION SPRINKLER SYSTEM FOR THE SINGLE FAMILY DWELLING UNIT SHALL BE DESIGNED AND INSTALLED PER NFPA 13D, 2013. 2. CALCULATION FOR THE RESIDENCE SHALL BE PER NFPA 13D, 2013. 3. PIPE THROUGHOUT THE DWELLING UNIT TO BE CPVC SPRINKLER PIPING UNLESS NOTED OTHERWISE. 4. ALL HANGERS SHALL BE PLACED AND INSTALLED IN ACCORDANCE WITH NEPA 13, 2013. 5. SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 SQ.FL AND LESS. 6. SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES THAT ARE LESS THEN 24 SQ.F7, THE LEAST DIMENSION DOES NOT EXCEED 3'-0 AND THE ROOM IS SURFACED WITH NONCOMBUSTIBLE OR LIMITED COMBUSTIBLE MATERIALS. 7. SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES, OPEN ATTACHED PORCHES, CARPORTS, AND SIMILAR STRUCTURES. 8. SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS, CONCEALED SPACES, FLOOR/CEILING SPACES, CRAWL SPACES, AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING PURPOSES AND DO NOT CONTAIN FUEL -FIRED EQUIPMENT. 9. WIRING OF ANY NEW DEVICES IF REQUIRED I5 BY OTHERS. 10. PAINTING AND LABELING.; OF PIPING IF REQUIRED 16 BY OTHERS. FIRE SPRINKLERS SHALL NOT BE PAINTED OVER, 11. IT SHALL BE THE OWNERS RESPONSIBILITY TO MAINTAIN THE TEMPERATURE ABOVE 40° AT ALL TIMES. 12. A MAIN DRAIN IS TO BE PROVIDED AND INSTALLED N ACCORDANCE WITH NFPA-130. HUB DRAINS TO BE PROVIDED BY OTHERS AS NEEDED. 13. NO GYP. BD. CEILINGS SHALL BE INSTALLED UNTIL ROUGH VISUAL INSPECTION IS COMPLETE. 14. MAXIMUM RESIDENTIAL PENDANT SPRINKLER SPACING COVERAGE 16'-O x 16'-0. MAXIMUM DRY SIDEWALL SPRINKLER HEAD SPACING 13'-0 X 14'-0. 15. MINIMUM RESIDENTIAL PENDANT SPRINKLER SPACING 8'-0 O.C. MINIMUM DRY SIDEWALL SPRINKLER SPACING 6'-0 O.C. 16. ALL VALVES TO BE LABELED IN ACCORDANCE WITH NFPA-13D. 17 PIPE SHAI 1 RF RFCDUIRFr TC) RFMAIN ON A 7 25" C,FNTFRI INF ON THF TOP C)F THF BOTTOM TRUSS CORD ALLOWING FOR TENTING AND SHALL HAVE PRIORITY OVER DTHER TRADES. GLACIER FIRE PROTECTION WILL PROVIDE ONE WET PIPE AUTOMATIC SPRINKLER SYSTEM TO PROTECT THE NEW RESIDENCE. EXCLUSIONS PAINTING OR LABELING OF PIPE AND/OR EQUIPMENT ELECTRICAL WIRING OF ANY KIND INCLUDING BUT NOT LIMITED TO WATERFLOW SWITCH, ELECTRIC BELL, AND TAMPER SWITCHES CENTRAL STATION MONITORING EQUIPMENT, WIRING AND SERVICES CEILING AND WALL REMOVAL/REPLACE 10 FACILITATE THE INSTALLATION OF THE SPRINKLER SYSTEM. UNDERGROJND WORK OF ANY KIND DESIGN CRIT RIA FIRE SPRINKLER RISER WATER GAUGE 314" DRAIN _.......... ,�.� DOMESTIC LINE BY OTHERS WATER FLOW CWITCH 1912" x 1" REDUCER GLACIER FIRE PROTECTION, LLC TO START WORK HERE 1112" AMES 2000E BACKFLOW PREVENTOR PROVIDED AND INSTALLED BY OTHERS .,._._.__........._. _._. 1112" WATER ENTRY BY OTHERS MAINTAIN 2"ANNULAR.-...... f! CLEARANCE AROUND PIPE I 173 PER NFPA 13D (2016) RM -01 (RESDENCE) THE DENSITY SHALL BE 13 GPM/SF OVER THE MOST REMOTE 2 SPRINKLER'S WITHIN A COMPARTMENT. 16-0 x 16'-0 MAX SPACING WATER FLOW INFORMATION VVATER FLOW INFORMATION HAS BEEN PROVIDED BY TUKWILA WATER STATIC: 150 PSI RESIDUAL: 20 PSI FLOW: 8000 GPM DRAWING INDEX FP 0.10 FP 2.10 SITE PLAN AND NOTES MAIN LEVEL & UPPER LEVEL PLAN Sprinkler Legend to EIL r rte•- F. >L en- 4. ev Finish White Chrome °» Response Quick Quick Quick Quick Type 'Size Pendent 1h zs in Sidewcl I 1 Pendent 1,4 Quantity K -Factor' 29# 4.9 Vr vi . • v 00 ..n. 1--..M II Es h t4ic'0 0 2 v) rw 0 0 iIu M LL z'0to� cc r r M Manufacturer [Reliable w . <a Ir w w .o . cc cn CC VC Symbol1 NORTH GLACIER FIRE PROTECTION LLC PO BOX 7980 BONNEY LAKE, WA 98391 a:(253) 501-7558 www.claclerfireprotection,com GLACIFP834MJ PARCEL # 334740-0555 VICINITY MAP CERTI l RR X0' 9 Erin Clayton 7544-0817-C Level 3 Glacier Fire Protection, L.L.C. GLACIFP834MJ 06/20/18 CONTRACT #: 40039 FLOOR /AREA SITE PLAN AND NOTES SHEET NUMBER PAID JUN 2121 TUKWILA e FP 0.10 IRE ,a„ CC i)1 COVERED PATIO 7777 NOOK 9'-0 A.F.F. KITCHEN 9'-0 A.F.F. STUDY 9'-0 A.F.F. OPEN TO ABOVE 81-0 • 1 \\ ... 4'-1 11A 3'-11'/2 C O GLACIER FIRE PROTECTION, LLC 0'-4'/ TO START @ BACKFLOW PREVENTOR APPROX. 4'-0 A.F.F. GARAGE 314" BATH 9'-OA,FF /; ) NEW 1" WATER METER BY OTHERS MAIN LEVEL PLAN SCALE : 1/4" = 1'-0 COVERED PORCH 2'-872 / AV 1 0'-4'/A 8'"0 4 1 0'-6 MASTER BEDROOM ..__..... VAULTED CEILING rn 3.-0 1 0'-472 T"7 0'-8 ////'///"/ UTILITY 8'-0 A.F.F. 10'-4'/2 BEDROOM 2 A.F.F. 1 BEDROOM 3 8'-0 A.F.F. co OPEN TO BELOW preariSVAINFAIW/, BATH 8'-0 A.F.F. I I 1 ;1 7'-6 \2'-672 T 0'-472 PLAYROOM 8'-0 A.F.F, REMOTE ARTA 8'-0 UPPER LEVEL PLAN SCALE : 1/4" = 1'-0 ARMOVER 1 DROP DROP DETAILS SCALE : N.T.S. PIPE SHALL BE REQUIRED TO REMAIN ON A 2.25" CENTERLINE ON TME TOP OF THE BOTTOM TRUSS CORD ALLOWING FOR TENTING AND SHALL HAVE PRIORITY OVER OTHER TRADES. ADEQUATE INSULATION BY OTHERS Hydraulic Information Remote Area 1 OCCUPANCY CLASSIFICATION Residential DENSITY 0.050gpnrifft2 for 900.00ft2 (Actual 261.60.T) TOTAL HEADS FLOWING 2 K -FACTOR 4.9 TOTAL WATER REQUIRED 26.33 TOTAL PRESSURE REQUIRED 56.918 BASE of RISER(gpm) 26.33 BASE of RISER (psi) 56.918 SAFETY MARGIN (psi) 193.002 (E2.1%) SPACING LEGEND _HANGER NOMINAL PIPE SIZE: IN. 3/4" 1" 1 1/4" 1 1/2" 2" 21/2" 3" 4" 6" 8" STEEL PIPE SCH 40, SCH 10, DF,EF 4, N/A 12-012-0 V 15-0 15-0 15-0 15-0 15-0 15-0 15-0 THREADED LIGHT ALL N/A 12-0 12-0 12-0 y 12-0 12-0 NIA N/A r N/A N/A COPPER 8-0 8.0 10-0 10-0 12-0 12-0 12-0 15-0 15-0 15-0 CPVC 5-6 6-0 6-6 7-0 8-0 9-0 10-0 NIA N/A N/A PER NFPA 139.2.2.1 (A) SPRAY RIGID i FOAM INSULATION / BY OTHERS i., • • ............ li • • Com. JJ PIPE TENT INSULATION DETAIL #1 SCALE :N.T.S. ELOWN-IN INSULATION ABOVE BATT INSULATION BY OTHERS BATT TYPE INSULATION COLD SPACE Sprinkler Legend I Finish I Temperature White 155`F ti u7 - Chrome 175'`'F U .� —1 Type !Size! Response Pendent ; 1/2 Quick �_^� /-/ V1 . ^ VJ Pendent F $i !Quick U. Model 'Quantify RFC491 29 !h ILE CC F3RES44 DRY 2 RFC 58! 1 coas co 11 Ti i- 1•Li) 4 CQ DC M t 4 1 W Manufa:tures Reliable m .0 Cl .0 ee N .a .0 a> .(0 :s— s -erre re 0 rinn con• n.,ri rnnn nr�n f)OO ()num,. `,'nun`. p -`-'n` 4-6? r):'nucy: ununhunU{�q- 5.)' � • . VAPU.,� OR )�r� BARRIER `ICJ.) ,j' U. --- SPRINKLER PIPE I. i TRUSS CHORD OR JOIST GYPSUM BOARD;, EI LING PIPE TENT INSULATION DETAIL #2 SCALE : N.T.S. STAND OFF HANGER #10x1" HEX HEAD ----------- CAP SCREW COMPOSITE WOOD-- I-JOIST OOD-----.-- I-JOIST SYP. BOARD/ T&G CEILING TM SPACE \\- SEMI-REC. PENDENT SPRINKLER INSUALTION BY OTHERS VAPOR BARRIER STAPLED 10d NAIL (TYP.) WOOD BLOCKING PIPE TENT INSULATION DETAIL #3 SCALE : N.T.S. MINIMUM DISTANCES FOR TEMPERATURE RESIDENTIAL SPRINKLERS HEAT SOUR;E 165 DEGREE 200 DEGREE 1 SIDE OF OPEN: OR RECESSED FIRE PLACE 36 in i 12 in FRONT OF RECESSED FIREPLACE COAL -OR WOOD BURNING STOVE KITCHEN RAPIGE WALL OVEN HOT AIR FLUES UNINSULATED HEAT DUCTS 60 in 42 in 18 in 18 in 18 in UNINSULATED HOT %ATER PIPES SIDE OF CEILING OR WALL MOUNTED HOT AIR DIFFUSERS FRONT OF WALL MOUNTED HOT AIR DIFFUSERS HOT WATER HEATER OR FURNACE LIGHT FIXTURE OW -250W 36 in 12 in 9in 9 in 18 in 12 in 24 in_ 36 in 6 in j PER NFPA 130 TABLE 7.$.5.3 6 in 9in 9in 6in 12 in 18 in 3in 3in GLACIER FIRE PROTECTION LLC PO BOX 7980 BONNEY LAKE, WA 98391 (253) 501-7558 www.ciacierfrepratection.com GLACIFP834MJ SPRINKLER PLAN S,aALE: 1/4"= DRAWN BY: SFC FLOOR / AREA MAIN LEVEL PLAN Erin Clayton 7544 -0B17 -C Level 3 Glacier Fire Protection, L.L.C. GLACIFP834MJ SHEET NUMBER