Fire Department Review
Control #D2000-297
(510)
Re: Fosterview Estates — lot 21— 13714 43rd Place South
Dear Sir:
The attached set of building plans has been reviewed by The Fire Prevention Bureau
and are acceptable with the following concerns:
1. The minimum fire flow and flow duration requirements for one- and two-family
dwellings having a fire area which does not exceed 3,600 square feet (344.5 m2)
shall be 1,000 gallons per minute (3785.4 L/min.). Fire flow and flow duration
for dwellings having a fire area in excess of 3,600 square feet (344.5 m2) shall
not be less than that specified in Table A -III -A-1. Exception: A reduction in
required fire flow of 50 percent, as approved by the chief, is allowed when the
building is provided with an approved automatic sprinkler system. (UFC
Appendix III -A, sec. 5.1)
2. Acceptance of residential fire sprinkler systems shall include field verification of
GPM and residual pressures meeting or exceeding the listing for the sprinkler
type.
All new sprinkler systems and all modifications to existing sprinkler systems shall
have fire department review and approval of drawings prior to installation or
modification. New sprinkler systems and all modifications to sprinkler systems
involving more than 50 heads shall have the written approval of the W.S.R.B.,
Factory Mutual, Industrial Risk Insurers, Kemper or any other representative
designated and/or recognized by The City of Tukwila, prior to submittal to the
Tukwila Fire Prevention Bureau. No sprinkler work shall commence without
approved drawings. (City Ordinance #1742)
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439
City of Tukwila
Steven M. Mullet, Mayor
Fire Department Thomas R Keefe, Fire Chief
Page number 2
Contact the Tukwila Fire Prevention Bureau to witness all required inspections
and tests. (UFC 10.503) (City Ordinance #1742)
3. All electrical work and equipment shall conform strictly to the standards of The
National Electrical Code. (NFPA 70)
An aisle to and working space shall be provided for each electrical panel. An
aisle width not less than 24 inches shall provide access to the panel and 30
inches of working space shall be provided directly in front of the panel. (NEC
110-16(a), NEC 110-16(c))
Each circuit breaker shall be legibly marked to indicate its purpose. (NEC 110-
22)
Any overlooked hazardous condition and/or violation of the adopted Fire or Building
Codes does not imply approval of such condition or violation.
Yours truly,
The Tukwila Fire Prevention Bureau
Cc: TFD file
Ncd
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439
13714 43RD PL 5
ASSOCIATED PERMITS
NONE
Project Name fc 5E' \,it ,,,,;)
Address 13..;11t ) t a 4 C.i(�.a 'L- Suite
Needs shift inspection
)'L. Approved without correction notice
Approved with correction notice issued
Sprinklers
Fire Alarm:
Hood & Duct:
Halon:
Monitor.
Pre -Fire:
Permits:
AuthorSig
Headquart s Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206.575-4404 • Fax: 206-575-4439