Loading...
HomeMy WebLinkAboutPP - 14828 46TH LN S - UNKNOWN - PERMITS AND PLANS14828 46TH LN S ASSOCIATED PERMITS 18-5-003 D17-0198 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PIERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: ct/ 1.44 5,(Ow (at W Type of Inspection , ( 4jPntact Suite#: �`' %; �� Person:Suite � Special Instructions: Phone No.: Approved per applicable codes. riCorrections required prior to approval. COMMENTS: “e,/ 4'notL alc (-( � tef FisS fre-linkt — Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: 4 CQ— Date: /AM f� Hrs.: ' $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip:: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /g -s- 603 PIERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 11°q^43° 4711 & dit U Type of In� ion: Address: Suite #: / ygze ix L N. Contact Person: Special Instructions: Phone No.: t Approved per applicable codes. Corrections required prior to approval. COMMENTS: T.�n/4;11. - ASS V- ± C\jLr Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: M53 Date: 2121 / 5 Hrs.: 1. 0 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 ( INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 4? -5 -otos PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-5754407 Project:/ 10/41,i r/oryl c 6or6 of Inspection: c dve-rz— Address:Contact Suite #: (41d4-6614 5_ Person: Special Instructions: Pre -Fire: Phone No.: per applicable codes. .k[forrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Al e --FD 7-/r/67 6� s &--0 F ,/ 4-L1"/C7 4) 5(A'/Ale-----, e— 6t, . C. u— tA7ftiE),–) ere-e)C.e (l6 1 -?=--- Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: V v` Date: i -i 3 f 1 X Firs.:/ 1 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 NORCO FIRE PROTECTION, INC. 24024 SE 261ST PLACE MAPLE VALLEY, WA 98038 HYDRAULIC CALCULATIONS FOR SIDHU HOMES LOT 8 TUKWILA, WASHINGTON FILE NUMBER: N16020 DATE: 6/6/16 -DESIGN DATA - OCCUPANCY CLASSIFICATION: RESIDENTIAL DENSITY: RESIDENTIAL .05 gpm/sq. ft. AREA OF APPLICATION: 2 HEADS sq. ft. COVERAGE PER SPRINKLER: 16 X 16 sq. ft. NUMBER OF SPRINKLERS CALCULATED: 2 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 0 gpm TOTAL WATER REQUIRED (including hose): 26.1 gpm FLOW AND PRESSURE (@ BOR): 26.1 gpm @ 33.5 psi SPRINKLER ORIFICE SIZE: 7/16 inch NAME OF CONTRACTOR: NORCO FIRE PROTECTION, INC. DESIGN/LAYOUT BY: EDWIN P COGAR AUTHORITY HAVING JURISDICTION: TUKWILA FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: NORCOFP015J0 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 50110271) HRS SYSTEMS, INC. TUCKER, GA 30084 WASHINGTON STATE CE!'TIFICATB OP COMPETENCY FIRE PROTECTION SPRINKLER SYSTEME Edwin P.o r 4295-049 -(,L' Level 3 Norco Fire Prrtec ' • n NORCOFP SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 ~DATE: 12/19/2017 C:\HASS DATA\HASS\2017 CALCS\N17097 SIDHU LOT 8 .SDF JOB TITLE: N17097 SIDHU LOT 8 WATER SUPPLY ANALYSIS Static: 75.00 psi Resid: 73.00 psi Flow: 50.0 gpm LEGEND 1 M Avaiiable pressure 74.40 psi @ 26.1 gpm 2 E Required pressure 51.03 psi @ 26.1 gpm A. Source Supply Curve B. System Demand Curve 20 30 40 50 60 70 80 90 100 FLOW (GPM) ote: (1) Dashed Lines indicate extrapolated values from Test Results SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 ,DATE: 12/19/2017 C:\HASS DATA\HASS\2017 CALCS\N17097 SIDHU LOT 8 .SDF JOB TITLE: N17097 SIDHU LOT 8 NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) A 75.0 73.0 50.0 74.4 26.1 51.0 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 26.1 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.1 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (FT) (PSI) (GPM) 1 29.0 K= 4.90 7.0 13.0 2 29.4 - - - - 7.3 - - - 3 29.0 K= 4.90 7.1 13.1 4 29.4 - - - - 7.4 5 29.4 8.2 6 29.4 8.2 7 19.4 13.1 8 19.4 13.9 9 19.4 16.4 10 9.4 22.2 W 7.4 25.9 B 0.0 46.4 C 0.0 37.9 D 0.0 36.1 E 2.0 33.5 F 2.0 29.0 A 0.0 SOURCE 51.0 26.1 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 12/19/2017 C:\HASS DATA\HASS\2017 CALCS\N17097 SIDHU LOT 8 .SDF JOB TITLE: N17097 SIDHU LOT 8 NFPA PIPE DATA Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) Z To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 1 4.90 13.0 Disch 5.0 10.75 150 0.3 2 29.4 7.3 0.0 1.000 5.00 -0.2 1 29.0 7.0 13.0 1.101 15.75 0.031 0.5 Pipe: 2 4.90 13.1 Disch 5.0 10.75 150 0.3 4 29.4 7.4 0.0 1.000 5.00 -0.2 3 29.0 7.1 13.1 1.101 15.75 0.031 0.5 Pipe: 3 0.0 0.0 1.5 14.25 150 0.1 4 29.4 7.4 4.5 1.000 1.50 0.0 2 29.4 7.3 4.5 1.101 15.75 0.004 0.1 Pipe: 4 0.0 4.5 2 6.5 7.29 150 0.7 5 29.4 8.2 13.1 3 1.000 6.50 0.0 4 29.4 7.4 17.6 1.101 13.79 0.054 0.7 Pipe: 5 0.0 17.6 4 32.5 75.91 150 0.1 6 29.4 8.2 -16.0 8 1.000 32.50 0.0 5 29.4 8.2 1.6 1.101 108.41 0.001 0.1 Pipe: 6 0.0 0.0 18.0 45.38 150 0.9 6 29.4 8.2 8.5 1.000 18.00 0.0 2 29.4 7.3 8.5 1.101 63.38 0.014 0.9 Pipe: 7 0.0 17.6 4 19.0 12.08 150 5.7 8 19.4 13.9 -1.6 6 1.000 19.00 4.3 5 29.4 8.2 16.0 1.101 31.08 0.045 1.4 Pipe: 8 0.0 8.5 2 19.0 11.41 150 4.9 7 19.4 13.1 1.6 5 1.000 19.00 4.3 6 29.4 8.2 10.1 1.101 30.41 0.019 0.6 Pipe: 9 0.0 0.0 8.0 30.62 150 0.7 8 19.4 13.9 10.1 6 1.000 8.00 0.0 7 19.4 13.1 10.1 1.101 38.62 0.019 0.7 Pipe: 10 0.0 10.1 7 28.0 54.87 150 2.5 9 19.4 16.4 16.0 5 1.000 28.00 0.0 8 19.4 13.9 12.9 1.101 82.87 0.030 2.5 Pipe: 11 0.0 10.1 7 36.0 91.04 150 8.3 10 9.4 22.2 16.0 5 1.000 36.00 4.3 8 19.4 13.9 13.2 1.101 127.04 0.031 4.0 Pipe: 12 0.0 0.0 24.0 25.17 150 5.8 10 9.4 22.2 12.9 8 1.000 24.00 4.3 9 19.4 16.4 12.9 1.101 49.17 0.030 1.5 Pipe: 13 0.0 12.9 9 20.5 4.71 150 3.7 W 7.4 25.9 13.2 8 1.000 20.50 0.9 10 9.4 22.2 26.1 1.101 25.21 0.111 2.8 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 ,DATE: 12/19/2017 C:\HASS DATA\HASS\2017 CALCS\N17097 SIDHU LOT 8 .SDF JOB TITLE: N17097 SIDHU LOT 8 Pipe Tag K-fac Add Fl Add F1 To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) Z To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 14 0.0 0.0 7.00 150 3.1 F 2.0 29.0 26.1 10 1.000 0.00 2.3 W 7.4 25.9 26.1 1.101 7.00 0.111 0.8 Pipe: 15 0.0 Fixed Pressure Loss Device E 2.0 33.5 26.1 W 4.5 psi, 26.1 gpm F 2.0 29.0 26.1 Pipe: 16 0.0 0.0 D 0.0 36.1 26.1 F E 2.0 33.5 26.1 Pipe: 17 0.0 0.0 C 0.0 37.9 26.1 E D 0.0 36.1 26.1 1.000 0.998 1.500 1.610 10.00 150 0.00 10.00 0.179 100.00 150 0.00 100.00 0.017 Pipe: 18 0.0 Fixed Pressure Loss Device B 0.0 46.4 26.1 D 8.5 psi, 26.1 gpm C 0.0 37.9 26.1 Pipe: 19 Source 0.0 A 0.0 51.0 26.1 C B 0.0 46.4 26.1 NOTES (HASS): 1.000 T: 5.9 0.998 20.00 150 5.93 25.93 0.179 (1) Calculations were performed by the HASS 8.7 computer program in accordance with NFPA13 (2016) under license no. 50110271 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.018 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 10.7 ft/sec at pipe 19. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) Available pressure at source node A under full flow conditions is 73.88 psi with a flow of 36.55 gpm. 2.7 0.9 1.8 1.7 0.0 1.7 4.6 0.0 4.6 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 ,DATE: 12/19/2017 C:\HASS DATA\HASS\2017 CALCS\N17097 SIDHU LOT 8 .SDF JOB TITLE: N17097 SIDHU LOT 8 (6) PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkV1v BfyVly GatVly AlmChk DPV1v NPTee 0.998 1.57 3.92 1.57 3.92 4.71 0.78 7.84 7.84 3.92 PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkV1v BfyVly GatVly AlmChk DPV1v Tee 1.610 4.00 8.00 2.00 9.00 6.00 1.00 10.00 10.00 8.00 PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) F E T R K C G F45 El Tee RunT Kplg ChkVly Gate 1.101 1.40 2.50 6.00 1.70 1.00 8.00 0.40 67'-0" 67'-0" 36' IEN:LUU HANDRAILS 42' 42EUU6 G642606A1S LANDING 46 SCFE. FRENCH DOORS S.G./7EOPERRED INT OF µRUNG BELOW 9'-2" _ 7'-8" I 10'-4" 7'-4 FAMILY ROOM 4'-51/2" BEDROOM -4 22'X30 ATTIC ACCTS 4'-10 1/2" N 634065 • /851 D/ -102 '-9 1/2" 15-1 O 15'-S 1/2" 3'-3 1/Z" DiSUITE 1, LAUNDRY 1'-6 1/2" SOLID C. 8EATH00851fOP SELF -CLOSER BEDROOM -1 8'-11 1/2" I 7-71/2'1 42' IONIAN GUARDRAILS b M,BATH -4112" 36' 14I60PJ0 HANDRAILS 36' 7000 HAYDRA'LS N - G - 11'-3" UNE OF FL..' AB. T.14. JOISTS LIVING 1PDT TO MOW BEDROOM -2 COVERED BALCONY 73 SCUT. 42' 604035 GUARDRAILS M 1MAIN FLOOR SPRINKLER PIPING PLAN - 67'-0" 16'-0" 20'-0" 12'-0" 19'-0" 6'86' POST ON 10'XIO' GONG. PER ON 3'%3%10' GONG. FOORNG 7TP. Yyp -ThEAL>- COVERED PATIO 16'-0" '5'-31/2" 12'-0 1/2" ' M 8'-2" - 1 12-012 N EGREATION 15'-10" ROOM 1 8'-2" 0-91 8-2 ED FUR SPRINKLER RISER LOCATION 11'-3" - 6'06' POST ON 10'x10' CONC. PIER CN Y%3'XIO' CS6C. F001160 411H f4 ROAR or 0.5. T. 14 HON. 11P. 18'-9" YIP -- ' NNINUU HANDRAAS It 15-1 9c.ffi 6'-8" 115 912 CAMEE ROOM N 5'-5" = 5'_9" -5 BELL f l Kl 6'-9" N 6'-9" 29'-6" 12'-6" 10'-0" 'NEATER 0 15'-0" 67'-0" LOWER FLOOR 1/8' - 1'-0' RINKLER PIPING PLAN BLAZEMASTER0 PIPE DIMENSIONS SDR 13.5 (ASTM F442) INCHES (MIWMETERS) NOMINAL SIZE AVERAGE OD AVERAGE ID POUNDS/FT. 3/4" (20.0) 1.050 (26.7) .874 (22.2) .168 1" (25.0) 1.315 (33.4) 1.101 (28.0) .262 134" (32.0) 1.660 (42.2) 1.394 (35.4) .418 1334" (40.0) 1.900 (48.3) 1.598 (40.6) .548 2" (50.0) 2.375 (60.3) 2.003 (50.9) .859 234" (65.0) 2.875 (73.0) 2.423 (61.5) 1.257 3" (80.0) 3.500 (88.9) 2.951 (75.0) 1.867 R-11 BAT MINIMUM SECURE INSULATION TO JO INSULATION TO SHEETROCK LEVEL - CUT INSULATION TO PUSH DOWN BETWEEN JOIST TENTING DETAIL C s 8' 10' 12' 14' 16' 18' INSULATION TO SHEETROCK LEVEL 1/2' SHEETROCK NOTES 6" ELECTRIC BELL WIRING AND CONDUIT BY OTHERS SECURE INSULATION TO JOIST R-11 BAT MINIMUM TENTING DETAIL A R-11 BAT MINIMUM TENTING DETAIL B INSULATION DOWN TO SHEETROCK LEVE 2' ATTIC JOIST INSULATION TO SHEETROCK LEVEL 11 2' ATTIC JOIST REVISIONS 2 X AM CF ROOF FRAMED R-49 AMC IISIATXW 1f• DRY845L 2'%r 80TTW TREATED PLATE 10'-0" rh UPPER FLOOR SPRINKLER PIPING PLAN 1/8.- T-0' 12 4r - NOTE: TRUSS LAYOUT WILL BE PROVIDE) TO THE PLAN EXAMINER 7 DAYS IN ADVANCE BEFORE INSTALLATION FOR APPROVAL, DESIGNED BY TRUSS CO. ENG. F--11611211. S/E OETER66D BY CPDOLG t�T11) GIN SPS 21.4 012b.0 TABLE 1 MAXIMUM SUPPORT SPACING DISTANCE END LINE SPRINKLER HEAD DROP ELBOW PIPE SIZE inches SYSTEM PRESSURE < 100 psi > 100 psi 3/4" 9" 6" 1" 12" 9" 114" 16" 12" 134"-3" 24" 12" TABLE 2 MAXIMUM SUPPORT SPACING DISTANCE INLINE SPRINKLER HEAD DROP TEE AIPE SIZE SYSTEM PRESSURE 7 inches < 100 psi > 100 psi 3/4" 4' 3' 1" 5' 4' 134' 6' 5' 1134"-3" 7' 7' 11E ROOF 184 SIRRNFPI0, RAM AT PAPER VENTINGY I \ m s 1" CPVC ADAPTER 1" CPVC--," s 1 = 1" STEEL PIPE 1' STEEL PIPE 1" STEEL PIPE 1" BACKFLOW DEVICE AMES 1"COPPER ADAPTER Ftnish Flow 1C i 34" MOM 80.T5 r aaSSDIT 0 48' 5PA@40 8'11424 CMG. MALL DRAIN TIE CONCRETE RA8 M16 IN. TAM MEM C,4R 4' COW= SAID Aro CRAWL BASE 0), BUILDING SECTION A 1/8' 1" GALV STEEL 90* ELECTRIC BELL WIRING AND CONDUIT AND INSTALLATION TO BE BY OTHERS CENTRAL RFE��ANFFIA FOLLLDWEH PRESS GAUGE SIGNS ON BODY DRAIN NORCO FIRE PROTECTION POINT OF CONNECTION DRAIN TO DISCHARGE OUTSIDE OF BUILDING 1' COPPER UNE FLOOR ---A CPVC DROP d = 0.329 FIRE SPRINKLER CPVC DROP FIRE SPRINKLER RISER DETAIL scale 12"=1'-O MAXIMUM SPACING OF HEADS TO BE 18 X 18 AND 9' OFF WALL IN SINGLE HEAD ROOM MAXIMUM SPACING OF HEADS TO BE 16 X 16 AND 8' OFF WALL IN MULTIPULE HEAD ROOM SPRINKLER SYMBOLS SYMBOLS LEGEND ® SYSTEMS RISER o RISE UP e DROP DN �-, 2 WAY EARTHQUAKE BRACE 4-1-.7-I- 4 WAY EARTHQUAKE BRACE GROOVED COUPLING 0 \#01 HANGER TYPE AND LOCATIONFAT> O UPRIGHT HEAD CA 25 ® PENDENT HEAD D SIDE WALL HEAD UPRIGHT OVER PENDENT PIPE SIZING HYDRAULIC CALC NODE REVISION NUMBER BRANCH LINE NUMBER WELD TAG NUMBER DATE DESCRIPTION BY SYM o a J. Fun dk8;0Rl01lt--1 TEMP K NPT 3/4' TAG PLY4000 MFG. MODEL# ESCUT TAL.OSB M/ II 38 G- CROSS ENDOW CR BAUD OR AS PER FLOOR COM 160 4.9 i BYowe RELIABLE RC 49 0 I Defaul ®° 1" CPVC ADAPTER 1" CPVC--," s 1 = 1" STEEL PIPE 1' STEEL PIPE 1" STEEL PIPE 1" BACKFLOW DEVICE AMES 1"COPPER ADAPTER Ftnish Flow 1C i 34" MOM 80.T5 r aaSSDIT 0 48' 5PA@40 8'11424 CMG. MALL DRAIN TIE CONCRETE RA8 M16 IN. TAM MEM C,4R 4' COW= SAID Aro CRAWL BASE 0), BUILDING SECTION A 1/8' 1" GALV STEEL 90* ELECTRIC BELL WIRING AND CONDUIT AND INSTALLATION TO BE BY OTHERS CENTRAL RFE��ANFFIA FOLLLDWEH PRESS GAUGE SIGNS ON BODY DRAIN NORCO FIRE PROTECTION POINT OF CONNECTION DRAIN TO DISCHARGE OUTSIDE OF BUILDING 1' COPPER UNE FLOOR ---A CPVC DROP d = 0.329 FIRE SPRINKLER CPVC DROP FIRE SPRINKLER RISER DETAIL scale 12"=1'-O MAXIMUM SPACING OF HEADS TO BE 18 X 18 AND 9' OFF WALL IN SINGLE HEAD ROOM MAXIMUM SPACING OF HEADS TO BE 16 X 16 AND 8' OFF WALL IN MULTIPULE HEAD ROOM SPRINKLER SYMBOLS SYMBOLS LEGEND ® SYSTEMS RISER o RISE UP e DROP DN �-, 2 WAY EARTHQUAKE BRACE 4-1-.7-I- 4 WAY EARTHQUAKE BRACE GROOVED COUPLING 0 \#01 HANGER TYPE AND LOCATIONFAT> O UPRIGHT HEAD CA 25 ® PENDENT HEAD D SIDE WALL HEAD UPRIGHT OVER PENDENT PIPE SIZING HYDRAULIC CALC NODE REVISION NUMBER BRANCH LINE NUMBER WELD TAG NUMBER DATE DESCRIPTION BY SYM CNT NAME METAL TEMP K NPT ORIF MFG. MODEL# ESCUT CONN. II 38 CONCEALED WHITE 160 4.9 1/2" 7/16 RELIABLE RC 49 2" Defaul ®° 5 DRY PEND WHITE 160 5.6 1" 1/2 RELIABLE F3QR ELBOW 45' Defaul 43 TOTAL HEADS ON THIS PROJECT DP. P180. BALL 2-YX4' ITP PUTT: 2'X4' sue or CC R-21 104 Ht7I. 2'X4' PRA. BOTTOM PLATE 8/ 1/2-3 AS. PPR 518. SHT. 1/2. 6158 811121. TYP. SECURE AGAINST UPWARD MOVEMENT GENERAL NOTES 1. System to be designed to N.F.P.A. #13D, 2007 edition and Fire Department requirements. 2. System hydraulically calculated to Fire Departments requirements and to N.F.P.A. 13D and Manufacturers Requirements. 3. Minimum pipe size to be 1" throughout job. 4. System to be hung per manufacturers requirements. Avcon Hangers to be used - Fig 511 & no block & head set. 5. All underground piping to conform to local Water Department requirements. This is for fill line only 6. Water information to be provided by pump manufacturer. Source of water by owner. 7. Transition from underground to riser to be copper type K typical unless noted otherwise 8. Risers that are exposed should be to be steel, cpvc is exceptable. Risers that rise up in wall to have typical access panel, provision of this panel to be per contract. 9. All electrical wiring and conduit for electrical switches to be by others. 10. Cleaning and painting of pipe to be by others, if required. 11. All drilling and notching to be per manufacturers specifications and Fire Department requirements. 12. All piping to be CPVC typical unless otherwise noted. 13. Items to be verified at time of inspection: a) Pressure at base of riser b) Sprinkler head location and spacing. c) Heads located from heat zones d) Exposed piping should be steel. e) Sprinkler heads in unconditioned areas to be 175° degrees 14. Alarm bells to be located per Fire Department requirements. 15. Testing of system to be per N.F.P.A. #13D and Fire Department Requirements. 16. Sprinklers may be omitted from closets less than 3'0" in depth or not over 24 sq. ft. ASTM F442 CPVC BRANCHLIIkJE FLOOR CEILING FLOOR FLOOR JOISTS FIRE SPRINKLER *NSF INTERNATIONAL APPROVED FOR USE WITH POTABLE WATER SECURE AGAINST UPWARD MOVEMENT ASTM F442 CPVC BRANCHLI E CEILING W. EXT. WALL COSTRUOR@4 SONG J{t' OSB 810110$40 2'70' STUDS ate 0.0 821 BATT 46ULA1158 18' GYPSUM BOARD 14A9I 10 tiff -rat -YAP= RAMER -DRYWALL FN90D GRADE Otlfrv Note: Section notes by P. Eng. shall have precedence over designer's FIRE SPRINKLER *NSF INTERNATIONAL APPROVED FOR USE WITH POTABLE WATER FLOOR JOISTS FAL CR BETTER SPRAY CR RIGID GDNT. INSUL BEIMEEN CCNC 11,4I1. AND SI= STEEL PIPE 11111 BLAZEMASTEI ' CPVC EMALE ADAPTER A A: (D -8")+B ' D 30" Al, (D-203mm)+B s D 762mm SOFFIT FORMULA PIPE HANGER (CLOSE TO TEE) K CEILING CURE TIMES WITH ONE S'SOLVENT CEMENT 200 psi (MAXIMUM) ILSI PRESSURE PIPE SIZE inches Ambient Temperature During Cure Period 60'F to 120'F 407 to 59'F OT to 39'F 3/4" 45 min. 1.5 hr. 24 hr. 1" 45 min. 1.5 hr. 24 hr. 134" 1.5 hr. 16 hr. 120 hr. 1334" 1.5 hr. 16 hr. 120 hr. 2" 8 hr. 36 hr. See Note 1 21%4' 8 hr. 72 hr. See Note 1 3" 8 hr. 72 hr. See Note 1 Note 1 For these sizes, the solvent cement con be applied at temperatures below 32'F, however, the sprinkler system temperature must be raised to a temperature of 32'F or above and allowed to cure per the above recommendations prior to pressure testing. ALLOWANCE FOR FRICTION LOSS IN CPVC FITTINGS (EXPRESSED IN EQUIVALENT FEET OF PIPE) FITTING PIPE DIAMETER 3/4" 1" 1 %" 1'h.. 2" 21h" 3" TEE BRANCH 3 5 6 8 10 12 15 TEE RUN 1 1 1 1 1 2 2 ELBOW 90' 7 7 8 9 11 12 13 ELBOW 45' 1 1 2 2 2 3 4 COUPLING 1 1 1 1 1 2 2 K FIRE SPRINKLER ASTM F442 C PVC BRANCHLINE WOOD JOISTS * NSF INTERNATIONAL APPROVED FOR USE WITH POTABLE WATER AFCON 511 C.P.V.C. PIPE HANGER SIDE MOUNT MATERIAL: CARBON STEEL APPROVALS: UL AND CUL LISTED. FINISH: MIL. GALVANIZED, G-90 GOVERNMENT SPEC. C.P.V.0 PIPE SIZE A B C MAX. HANGER SPACING (FT) 3/4" 31/8" 19/16 13/16 51/2 1" 33/8" 111/16 13/16 6 11/4" 43/16" 23/32 13/16 6112 1 1/2" 4 7/16' 2 7/32 13/16 7 2" 4 7/8" 2 7/16 1 3/16 8 BLAZEMASTER® PIPE SDR 13.5 (ASTM F442) HANGER SPACING NOMINAL SIZE MAX SPACING inches (mm) feet (m) 3/4" (20.0) 5.5' (1.7) 1" (25.0) 6.0' (1.8) 1134" (32.0) 6.5' (2.0) 1334" (40.0) 7.0' (2.1) 2" (50.0) 8.0' (2.4) 234" (65.0) 9.0' (2.7) 3" (80.0) 10.0' (3.0) CURE TIMES WITH ONE STEP SOLVENT CEMENT 200 psi (MAXIMUM) TEST PRESSURE PIPE SIZE inches Ambient Temperature During Cure Period 60'F to 120'F 40'F to 59'F O'F to 39'F 3/4" 45 min. 1.5 hr. 24 hr. 1' 45 min. 1.5 hr. 24 hr. 134" 1.5 hr. 16 hr. 120 hr. 1131" 1.5 hr. 16 hr. 120 hr. 2' 8 hr. 36 hr. See Note 1 234" 8 hr. 72 hr. See Note 1 3' 8 hr. 72 hr. See Note 1 Note 1 For these sizes, the solvent cement can be applied at temperatures below 32'F, however, the sprinkler system temperature must be raised to a temperature of 32'F or above and allowed to cure per the above recommendations prior to pressure testing. PERMISSIBLE BENDING DEFLECTIONS SDR 13.5 (73'F) (ONE END. RESTRAINED) PIPE SIZE inches LENGTH OF RUN (L) IN FEET 2' 5' 7' 10' 12 15' 17' 20' 3/4" 1.3" 7.8" 15.4" 31.3" 45.1" 70.5" 90.6" 125.4" 1" 1.0" 6.3" 12.3" 25.0" 36.0" 56.3" 72.3" 100.1" 11/4" 0.8" 5.0" 9.7" 19.8" 28.5" 44.6" 57.3" 79.3" 1 h" 0.7" 4.3" 8.5" 17.3" 24.9" 39.0" 50.1" 69.3" 2" 0.6" 3.5" 6.8" 13.9" 20.0" 31.2" 40.0" 55.4" 21h" 0.5" 2.9" 5.6" 11.4" 16.5" 25.8" 33.1" 45.8" 3" 0.4" 2.4" 4.6" 9.4" 13.5" 21.2" 27.2" 37.6" BACKFLOW ASSEMBLY REQUIRED IS PER STATE PLUMBING CODE BACKFLOW ASSEMBLY IS REQUIRED BY WATER DEPARTMET NOT FIRE DEPARTMENT AND IS PART OF THE POTABLE WATER SYSTEM PERMITING AND INSTALLATION AND TESTING TO BE DONE BY OTHERS L2 D ORCO Fire Protection, Inc. PO Box 363 Ravensdale, WA 98051 425-432-7250 OWNER INFORMATION NAME RSVP REAL ESTATE, INC. ADDRESS 10900 NE 8TH ST, STE 1000 BELLEVUE, WA PHONE 206-244-1900 FIRE DEPT INFORMATION NAME TUKWILA FIRE DEPT ADDRESS 444 ANDOVER PAARK EAST TUKWILA, WA 98188 PHONE 425-481-8827 WATER DEPT. INFORMATION NAME ADDRESS PHONE WATER INFORMATON STATIC 75 RESIDUAL 20 GPM 4856 MAIN SIZE 8" SOURCE AS BUILT DRAWING TUKWILLA WATER DEPT BUILDING INFORMATION SQ. FT. 5146 SQ.FT. TYPE Wood Frame OCCUPANCY Residential LEGAL DESCRIPTION TAX PARCEL ID# 0042000131 • VICINITY MAP WASHINGTON STATE CERTIFICATE OP COMPETENCY luta PROTEc71ioN $PRIHIa3A :yams NOR d21 g 04.9 q r NorcoCOF Fire P Lgvet- , I6n l a Inc •' SIDHU HOMES LOT 8 14828 46TH LANE S TUKWILLA, WA 98178 CONTRACTOR NORCO FIRE PROTETION, INC. PAID Prc 21201? TUKWILA FIRE PIPING PLAN AREA 1 PERMIT NO. CONTRACT NO. N17097 APPROVAL TUKWILLA FIRE DRAWN BY ED COGAR SCALE 1/8" = 1'-0" DATE 12/12/17 REVISED PLOTTED FP1of1 (11y ?21 /-,V/ L. w N .,' Q+ Q) c.'. 014. 0 Gc ii O)r O ;---; .1_+Ca �oOLQVC)h",,Lt,RCLS 3. iD8 Cs -s.0 1Lr`�j .. CD Qu Q) 4- Q vi 07 w ? rIn.„ .' C J izs h > c,. 'L .: n j '' --' ' ro -- . : c) _ . " cn 4) QS Q O -C C v Q) .0 C) f.... - L ' -En. C () ...0 _ ID O C. C: nn h to til N Cl. Q) a. ° 12 Q'i ua O. >a:)�-cnv) c) y m i 8 4 Q) c7 ti Q) Q) ❑ t' 1711 12 (13 L, Q C Unj` u% ;v Q) ? Q) L. (6 0 O (p C n 72 E e 4 t -QC) Q) t .fi `.ri UJ TJ Vi f6 Q) - l 'L:! 0 CQ 3 60 ca. Bei (t) 0 u ,r3 ra tis t 6 �4