Loading...
HomeMy WebLinkAboutPP - 14816 46TH LN S - UNKNOWN - PERMITS AND PLANS14816 46TH LN S ASSOCIATED PERMITS 16-5-733 D15-0309 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit D 1 S - O3 oy PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: Cr4r-,/ SN.111 Type of Inspection: 51444- 4- - lqs i - Address: • l Lbr! ie `t wr. Li, S . Suite #: Contact Person: Special Instructions: Phone No.: KApproved per applicable codes. [-I Corrections required prior to approval. COMMENTS: f3„ -- 4-44— o k keod1 --� �7 5pti e IN* 14 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: -y,,v J-1 \ Date: y,.1,7, / 2 Hrs.: 1 n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 ♦ . 2 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit Of r f e • i . DIS -030°1 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Pro'ect: C Ty a of Inspection: tom+. Ad ress:Contact Suite #: 14$t o 4:Votb LH S Person: Special Instructions: Phone No.: 5::"t1 Approved per applicable codes. Corrections required prior to approval. COMMENTS: -4111. vkckL Needs Shift Inspection: Sprinklers: kf<s ts.D Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:-... Date: z--)11-4._Hrs.: 1 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 6-5-0(33 LS- Oat" PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: ) i.DA -� s Type of Inspection: _ ,Com s lcr .kis, Address:Contact Suite #: ),6t2,' 4 S Person: C.cci 51 Special Instructions: Phone No.: j21Approved per applicable codes. I I Corrections required prior to approval. COMMENTS: ak kz cA�c Needs Shift Inspection: Sprinklers: i'e Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: -4-\,‘,5'''l Date: (pl Z$� kce, Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 New addresses for Gary Singh residential project in the 4600 block of S. 148th Street per the drawing dated 10/3/07 (addresses based on the hand written lot numbers). Lot 1 — 4615 South 148th Street has been changed to 14809 — 46th Lane South on April 13, 2010 Lot 2 —14811 — 46th Lane South Lot 3 —14817 — 46th Lane South Lot 4 —14825 — 46th Lane South Lot 5 — 4635 South 148th Street. Lot 6 — 4637 South 148th Street. Lot 7 —14816 — 46111 Lane South Lot 8 —14831 — 46th Lane South Lot 9 — 14837 — 46th Lane South Lot 10 —14834 — 46th Lane South Lot 11 — 14828 — 4611h Lane South Lot 12 4645 South 14811h Street. C at .007- e,v 30 _ erz_6 7-3d- Z 5.0 17C S hOifly peed 'L r Z 5' NORCO FIRE PROTECTION, INC. 24024 SE 261ST PLACE MAPLE VALLEY, WA 98038 HYDRAULIC CALCULATIONS FOR SIDHU HOMES TUKWILA, WASHINGTON FILE NUMBER: N16020 DATE: 6/6/16 -DESIGN DATA - OCCUPANCY CLASSIFICATION: RESIDENTIAL DENSITY: RESIDENTIAL .05 gpm/sq. ft. AREA OF APPLICATION: 2 HEADS sq. ft. COVERAGE PER SPRINKLER: 16 X 16 sq. ft. NUMBER OF SPRINKLERS CALCULATED: 2 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 0 gpm TOTAL WATER REQUIRED (including hose): 26.2 gpm FLOW AND PRESSURE (@ BOR): 26.2 gpm @ 22.4 psi SPRINKLER ORIFICE SIZE: 7/16 inch NAME OF CONTRACTOR: NORCO FIRE PROTECTION, INC. DESIGN/LAYOUT BY: EDWIN P COGAR AUTHORITY HAVING JURISDICTION: TUKWILA FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: NORCOFP015JO CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 50110271) HRS SYSTEMS, INC. TUCKER, GA 30084 • WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Edwin R Cogar 4295 -0499 -CG Level 3 Norcu rirc Pre .rtignrInc. NORCOFP ature O V Expires i 1211/16 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 6/7/2016 C:\HASS\DATA\2016 CALCS\N16020 SIDHU LOT 3.SDF JOB TITLE: N16020 SIDHU LOT 3 SUPPLY ANALYSIS 0 l() M 3 0 m 4-4 O O OD 00 r 0 0 0 rn 0 ro U) • NI a) a) U • U te• a) u)O 0 a) -I O co O >, N 0 0 0 O 0 0 0 0 d. 0 0 0 O O i O' N CO00 l0 0 `—' 0FC0t.7w arzwu)mnrzw--- 0,m-ri,. O to Dashed Lines indicate 0) o SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 6/7/2016 C:\HASS\DATA\2016 CALCS\N16020 SIDHU LOT 3.SDF JOB TITLE: N16020 SIDHU LOT 3 NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) A 90.0 88.0 35.0 88.8 26.2 40.2 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 26.2 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.2 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (FT) (PSI) (GPM) 1 19.0 K= 4.90 7.0 13.0 2 19.4 7.2 3 19.0 K= 4.90 7.3 13.2 4 19.4 7.4 5 19.1 7.6 6 19.4 8.3 7 19.4 8.3 8 19.4 8.4 9 19.4 8.4 10 19.4 8.4 11 9.4 13.5 12 9.4 13.6 W 9.4 14.4 B 0.0 37.3 C 0.0 28.8 D 0.0 27.0 E 2.0 22.4 F 2.0 18.4 A 0.0 SOURCE 40.2 26.2 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 6/7/2016 C:\HASS\DATA\2016 CALCS\N16020 SIDHU LOT 3.SDF JOB TITLE: N16020 SIDHU LOT 3 NFPA PIPE DATA Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 1 4.90 13.0 Disch 5.0 5.67 150 0.1 2 19.4 7.2 0.0 1.000 5.00 0.2 1 19.0 7.0 13.0 1.101 10.67 0.031 0.3 Pipe: 2 0.0 0.0 5.0 4.50 150 0.4 5 19.1 7.6 13.0 1.000 5.00 -0.1 2 19.4 7.2 13.0 1.101 9.50 0.031 0.3 Pipe: 3 4.90 13.2 Disch 5.0 5.41 150 0.2 4 19.4 7.4 0.0 1.000 5.00 0.2 3 19.0 7.3 13.2 1.101 10.41 0.032 0.3 Pipe: 4 0.0 0.0 5.0 5.00 150 0.2 5 19.1 7.6 4.6 1.000 5.00 -0.1 4 19.4 7.4 4.6 1.101 10.00 0.004 0.0 Pipe: 5 0.0 0.0 19.5 49.20 150 1.0 10 19.4 8.4 8.7 1.000 19.50 0.0 4 19.4 7.4 8.7 1.101 68.70 0.014 1.0 Pipe: 6 0.0 1.4 8 6.5 8.50 150 0.0 10 19.4 8.4 1.9 7 1.000 6.50 0.0 9 19.4 8.4 3.3 1.101 15.00 0.002 0.0 Pipe: 7 0.0 3.3 6 11.0 47.20 150 0.0 9 19.4 8.4 -1.4 8 1.000 11.00 0.0 7 19.4 8.3 1.9 1.101 58.20 0.001 0.0 Pipe: 8 0.0 17.6 5 5.0 4.54 150 0.0 7 19.4 8.3 -14.3 12 1.000 5.00 0.0 6 19.4 8.3 3.3 1.101 9.54 0.002 0.0 Pipe: 9 0.0 4.6 4 5.0 10.67 150 0.7 6 19.4 8.3 13.0 2 1.000 5.00 0.1 5 19.1 7.6 17.6 1.101 15.67 0.054 0.8 Pipe: 10 0.0 0.0 5.0 10.08 150 0.0 9 19.4 8.4 1.4 7 1.000 5.00 0.0 8 19.4 8.4 1.4 1.101 15.08 0.001 0.0 Pipe: 11 0.0 3.3 6 23.5 60.75 150 0.0 8 19.4 8.4 -1.9 9 1.000 23.50 0.0 7 19.4 8.3 1.4 1.101 84.25 0.001 0.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 6/7/2016 C:\HASS\DATA\2016 CALCS\N16020 SIDHU LOT 3.SDF JOB TITLE: N16020 SIDHU LOT 3 Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 12 11 10 Pipe: 13 12 6 9.4 19.4 9.4 19.4 0.0 13.5 8.4 0.0 13.6 8.3 3.3 9 8.7 4 11.9 17.6 5 -3.3 7 14.3 Pipe: 14 0.0 11.9 10 12 9.4 13.6 -10.0 W 11 9.4 13.5 1.9 Pipe: 15 W 12 Pipe: 16 W 11 Pipe: 17 F W 9.4 9.4 9.4 9.4 2.0 9.4 0.0 14.4 13.6 0.0 14.4 13.5 0.0 18.4 14.4 Pipe: 18 E 2.0 22.4 F 2.0 18.4 1.9 11 14.3 6 16.2 11.9 10 -1.9 12 10.0 10.0 11 16.2 12 26.2 0.0 26.2 W 26.2 12.0 1.000 1.101 12.0 1.000 1.101 26.0 1.000 1.101 6.5 1.000 1.101 19.0 1.000 1.101 1.000 1.101 15.50 150 12.00 27.50 0.026 12.87 150 12.00 24.87 0.037 64.65 150 26.00 90.65 0.001 12.17 150 6.50 18.67 0.046 30.50 150 19.00 49.50 0.019 7.00 150 0.00 7.00 0.112 Fixed Pressure Loss Device 4.0 psi, 26.2 gpm 5.1 - 4.3 0.7 5.2 - 4.3 0.9 0.1 0.0 0.1 0.9 0.0 0.9 0.9 0.0 0.9 4.0 - 3.2 0.8 Pipe: 19 0.0 0.0 10.00 150 4.6 D 0.0 27.0 26.2 F 1.000 2E: 4.7 10.67 -0.9 E 2.0 22.4 26.2 0.998 T: 5.9 20.67 0.181 3.7 Pipe: 20 0.0 0.0 C 0.0 28.8 26.2 E D 0.0 27.0 26.2 1.500 1.610 100.00 150 0.00 100.00 0.018 Pipe: 21 0.0 Fixed Pressure Loss Device B 0.0 37.3 26.2 D 8.5 psi, 26.2 gpm C 0.0 28.8 26.2 Pipe: 22 Source 0.0 A 0.0 40.2 26.2 C B 0.0 37.3 26.2 1.000 T: 5.9 0.998 10.00 150 5.93 15.93 0.181 1.8 0.0 1.8 2.9 0.0 2.9 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 6/7/2016 C:\HASS\DATA\2016 CALCS\N16020 SIDHU LOT 3.SDF JOB TITLE: N16020 SIDHU LOT 3 NOTES (HASS): (1) Calculations were performed by the HASS 8.5 computer program under license no. 50110271 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.005 gpm and a maximum imbalance at any node of 0.083 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 10.8 ft/sec at pipe 19. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) Available pressure at source node A under full flow conditions is 86.19 psi compared to the minimum required pressure of 20.00 psi. (6) PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVly BfyVly GatVly AlmChk DPV1v NPTee 0.998 1.57 3.92 1.57 3.92 4.71 0.78 7.84 7.84 3.92 PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVly BfyVly GatVly AlmChk DPV1v NPTee 1.610 4.00 8.00 2.00 9.00 6.00 1.00 10.00 10.00 8.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 6/7/2016 C:\HASS\DATA\2016 CALCS\N16020 SIDHU LOT 3.SDF JOB TITLE: N16020 SIDHU LOT 3 PAGE: F Diameter (in) 1.101 MATERIAL: CPVC HWC: 150 Equivalent Fitting Lengths in Feet F E T R K C F45 El Tee RunT Kplg ChkVly 1.00 5.00 5.00 1.00 1.00 8.00 G Gate 2.00 68'-5" 4'-O" 64'-5" eN N 16'-4" 14'-5" 5'-8'1 6'-0" 22'-0" 71_91, 71_911 7'-2 1 /2" 7'-2 1/2" 2'-10" 9'-6" 5'-6" BEDROOM -2 1 BEDROOM -1 W.I.C. K ENSUITE JACUZZI 4X5 2 ui 1 01 52 ATT I IACCESP L-_4 '-11 W.I.C. 213MOHS /eru D/s BATT{ '-10" 12'-2 1 11 11'-10 1/2" 5'-3 1/Z: 412 3'- 11 1r. 42' MIN 12-21 GUARDRAILS N • \ / 2-5 / / OPE! BEl 71_911 4TO\\\ OW 11-1012 -4 6'-6" CO FV 42' M:NIMU ti N -612 4'-6 1/2" -712 5-0 4-6 1-61 MAS'�R BEDS 12'-7 In" ;It =r 3'-11 1/2" -312 1, x '1" \ -. 36- MINIMU HANDRAILS r 5'-6" 11 - BEDROOM -3 4'-8 1/2" //J_ 11 \ LL 11-0�\ 11412 • 11'-41/ � 11'-41Y2.'`r� OPEN TO II BELON( 11=412 42 MINIMI N 05 1 1�. 7 UARDRAILS 6x r L oo 4,-V" 4 - C-6 4'-6" BALCONY II mil 6EALI �� 66' OSXT r- 00 16'-0" 14'-O" 16'-5" 16'-0" 6'-0" 68'-5" G 41-0n rh UPPER FLOOR SPRINKLER PIPING PLAN 1/8" = 1'-011 64'-5" r. 16'-0" 16'-5" 6'-8" 25'-4" 71..911 71..911 7'-10 1/2" 7'40 1/2" 5' 3'-0" 3'-8" 3'-4" 16'-0" 6'-0" r .0. NOOK r T.J.I. KITCHEN ISTS 1 • T.J.I. JC 15T5 BEDROOM -5 1 W.I.C. 3-11 . JOISTS O H.W. i.1). FURN. 3'-9 1/2" 10'-0" 17'-2 1/2" Je pio T.J.I. JOISTS 2 SLAND O RE N 11-2T2 • 2iO • I MUD ROOM Wff) 1a�11�" 3 x 5-712 4'-9,, 3'-4" .1. JOISTS 4-0 F -012 11. '0 FAMILY ROOM OPEN TO ABOVE 16'-0" R-11 BAT MINIMUM SECURE INSULATION TO JOIST INSULATION TO SHEETROCK LEVEL- 6'-4 1/2" 6'-6" �1 1�=rr-s-=1=1r=t 10\ JII Ir- 4 DINING T.J.I. JOISTS 1r, 36.1 INIMUI. HAND' AILS II N /--- 16f#UP `l ENTRY ---1B'z24' MIN. CRAWL SPACE ACCESS AT WALL 5R UP 10-0 GARAGE 1.415. 2Y SLAB & DRIVEWAY AT SLOPE VIII FIRE SPRINIQ ER-'ISylLPI OCATION 11GARAGEIII I NII III III=' III O • II r II P1 111 111 Iii 111 6X6' POST 4-11 /7'3 36' MINIMUM HANDRAILS /-SOLID CORE. / WEATHERSTRIP SELF -CLOSER 1 L 14'-O" 68'-5" 16'-5" LIVING •M zee 16'-0" rh MAIN FLOOR SPRINKLER PIPING P /8" = ,1-011 CUT INSULATION TO PUSH DOWN BETWEEN J01ST TENTING DETAIL C INSULATION TO SHEETROCK LEVEL 1/2" SHEETROCK SECURE INSULATION TO JOIST R-11 BAT MINIMUM TENTING DETAIL A R-11 BAT MINIMUM INSULATION DOWN TO SHEETROCK LEVEL 2" ATTIC JOIST INSULATION TO SHEETROCK LEVEL //--- TENTING DETAIL B 2' ATTIC JOIST 2 X TRUSS OF ROOF FRAMING R-49 ATTIC INSULATION YI DRYWALL 1/2" TEMERED SAND BLAST CLASS BOTTOM MID TOP PLATE ALUM. CHANEL FASTEN TO BOTTOM AND TOP PLATE 2'A6" BOTTOM TREEpLALTppEE7DDE 10' z 46' ANCHOR BOLTS 7• EMBEDMENT 0143205000103 BEDROOM -3 NOTE: TRUSS LAYOUT WILL BE PROVO TO THE FLAN EXAMINER 7 DAYS IN ADVANCE BEFORE INSTALLATION FOR APPROVAL, DESIGNED BY TRUSS CD. ENG. ((SIZE DETERMNED BY OPDWNG WITH) STUDS 2%4 0 12.0.C. TOP FLOOR=305.5' 8THICK CONC. WALL DRAIN TRE SECURE AGAINST UPWARD MOVEMENT TION TVP. FI OOR Y:ONSTRI IC TIONJ 1" T&G PLYWOOD T.J.I. JOISTS W/ CROSS BRIDGING OR BLOCKING DINING 2331: CONTINUOUS CONSTRUCTION JOINER LAUNDRY 3'-0' VIDE MIN. CRAYL SPACE ACCESS 1_ 1 (1) /4 CONTBAJDUS REBAR SECTION A 1Y JOISTS OR SIZE OF T4.1. AS 1WTED BY ENGINEER KITCHEN NOOK MAIN FLOOR=295.6' CcccWi c() INSULATION CONC. 1 1 ROOF 1X4 STRAPPING. BUILDING PAPER •RIDGE VENTING GUTTERS TVP. EXT. WA1 L COTSIRL/'n0": BUILDING WRAP HARDI-PUY4( SONG 1(s OSB SHEATHING 2X6' STUDS 016- 0.C. R21 BATT INSUTATKIN r GYPSUM BOARD TTRSM TO (TRW -FRAMING -INSULATION -VAPOUR BARRIER -DRYWALL 111114ED GRADE SCALE:1/4"-1' ASTM F442 CPVC BRANCHLIftJE FLOOR CEILING FLOOR JOISTS FIRE SPRINKLER *NSF INTERNATIONAL APPROVED FOR USE WITH POTABLE WATER FLOOR SECURE AGAINST UPWARD MOVEMENT ASTM F442 CPVC BRANCHLINE CEILING FIRE SPRINKLER *NSF INTERNATIONAL APPROVED FOR USE WITH POTABLE WATER FLOOR JOISTS s 1" CPVC ADAPTER STEEL PIPE 1' CPVC 1" STEEL PIPE 1' STEEL PIPE 1' STEEL PIPE �`►�"I"T.I" 1" BACKFLOW DEVICE AMES 1' COPPER ADAPTER Finish Floor BLAZEMASTEFP CPVC EMALE ADAPTER 1' GALV STEEL 90' ELECTRIC BELL WIRING AND CONDUIT AND INSTALLATION TO BE BY OTHERS CENTRAL RISER MANIFOLD W/: 1 DRAIN AND EST 2 FLOW SWIT H 3 PRESSURE UGE 4 SIGNS ON BODY DRAIN NORCO FIRE PROTECTION POINT OF CONNECTION DRAIN TO DISCHARGE OUTSIDE OF BUILDING `1" COPPER UNE RISER DETAIL scale 1/2'=1'-0' 6" ELECTRIC BELL WIRING AND CONDUIT BY OTHERS ALLOWANCE FOR FRICTION LOSS IN CPVC FITTINGS (EXPRESSED IN EQUIVALENT FEET OF PIPE) FITTING PIPE DIAMETER 3/4" 1" 114" " 1 1" 2" 21' 3" TEE BRANCH 3 5 6 8 10 12 15 TEE RUN 1 1 1 1 1 2 2 ELBOW 90' 7 7 8 9 11 12 13 ELBOW 45' 1 1 2 2 2 3 4 COUPLING 1 1 1 1 1 2 2 TABLE 1 MAXIMUM SUPPORT SPACING DISTANCE END UNE SPRINKLER HEAD DROP ELBOW PIPE SIZE inches SYSTEM PRESSURE < 100 psi > 100 psi 3/4" 9" 6" 1" 12" 9" 134" 16" 12" 1 34"-3" 24" 12" TABLE 2 MAXIMUM SUPPORT SPACING DISTANCE INLINE SPRINKLER HEAD DROP TEE PIPE SIZE inches SYSTEM PRESSURE < 100 psi > 100 psi 3/4" 4' 3' 1" 5' 4' 11/" 6' 5' II/C.-3" 7' 7' 6.5.3 A warning sign, with minimum Vo inch letters, shall be affixed adjacent to the main shutoff valve and shall state the following: WARNING: The water system for this home supplies fire sprinklers that require certain flows and pressures to fight a fire. Devices that restrict the flow or decrease the pressure or automatically shut off the water to the fire sprinkler system, such as water softeners, filtration systems, and automatic shut-off valves, shall not be added to this system without a review of the fire sprinkler system by a fire protection specialist. Do not remove this sign. C SEE TABLE BELOW FOR NUMBER OF HANGERS REQUIRED \-ASTM F442 CPVC MINIMUM ALLOWABLE HANGERS PER LENGTH OF PIPE PIPE SIZE inches Pipe Length 1 Hanger 2 Hangers 3 Hangers 1.050 (26.7) .874 (22.2) .168 24 hr. 1" 45 min. 1.5 hr. 24 hr. 40' 45' 50' 21 391/3162 134" 1.5 hr. 16 hr. 2" (50.0) 2.375 (60.3) 2.003 (50.9) .859 See Note 1 234" 8 hr. 72 hr. 3" (80.0) 3.500 (88.9) 2.951 (75.0) 1.867 See Note 1 *NSF INTERNATIONAL APPROVED FOR USE WITH POTABLE WATER BLAZEMASTER® PIPE DIMENSIONS SDR 13.5 (ASTM F442) INCHES (MILLIMETERS) NOMINAL SIZE AVERAGE OD AVERAGE ID POUNDS/FT. 3/4" (20.0) 1.050 (26.7) .874 (22.2) .168 24 hr. 1" 45 min. 1.5 hr. 24 hr. 40' 45' 50' 21 391/3162 134" 1.5 hr. 16 hr. 2" (50.0) 2.375 (60.3) 2.003 (50.9) .859 See Note 1 234" 8 hr. 72 hr. 3" (80.0) 3.500 (88.9) 2.951 (75.0) 1.867 PIPE HANGER (CLOSE TO TEE) ASTM F442 CPVC CEILING FIRE SPRINKLER WOOD JOISTS * NSF INTERNATIONAL APPROVED FOR USE WITH POTABLE WATER FLOOR GENERAL NOTES 1. System to be designed to N.F.P.A. #13D, 2007 edition and Fire Department requirements. 2. System hydraulically calculated to Fire Departments requirements and to N.F.P.A. 13D and Manufacturers Requirements. 3. Minimum pipe size to be 1" throughout job. 4. System to be hung per manufacturers requirements. Avcon Hangers to be used - Fig 511 & no block & head set. 5. All underground piping to conform to local Water Department requirements. This is for fill line only 6. Water information to be provided by pump manufacturer. Source of water by owner. 7. Transition from underground to riser to be copper type K typical unless noted otherwise 8. Risers that are exposed should be to be steel, cpvc is exceptable. Risers that rise up in wall to have typical access panel,. provision of this panel to be per contract. 9. All electrical wiring and conduit for electrical switches to be by others. 10. Cleaning and painting of pipe to be by others, if required. 11. All drilling and notching to be per manufacturers specifications and Fire Department requirements. 12. All piping to be CPVC typical unless otherwise noted. 13. Items to be verified at time of inspection: a) Pressure at base of riser b) Sprinkler head location and spacing. c) Heads located from heat zones d) Exposed piping should be steel. e) Sprinkler heads in unconditioned areas to be 175° degrees 14. Alarm bells to be located per Fire Department requirements. 15. Testing of system to be per N.F.P.A. #13D and Fire Department Requirements. 16. Sprinklers may be omitted from closets less than 3'0" in depth or not over 24 sq. ft. CURE TIMES WITH ONE STEP SOLVENT CEMENT 200 psi (MAXIMUM) TEST PRESSURE PIPE SIZE inches Ambient Temperature During Cure Period 60'F to 120'F 40'F to 59'F O'F to 39'F 3/4" 45 min. 1.5 hr. 24 hr. 1" 45 min. 1.5 hr. 24 hr. 40' 45' 50' 21 391/3162 134" 1.5 hr. 16 hr. 120 hr. 2" 8 hr. 36 hr. See Note 1 234" 8 hr. 72 hr. See Note 1 3" 8 hr. 72 hr. See Note 1 Note 1 For these sizes, the solvent cement can be applied at temperatures below 32'F, however, the sprinkler system temperature must be raised to a temperature of 32'F or above and allowed to cure per the above recommendations prior to pressure testing. CURE TIMES WITH ONE STEP SOLVENT CEMENT 200 psi (MAXIMUM) TEST PRESSURE PIPE SIZE inches Ambient Temperature During Cure Period 60'F to 120'F 40'F to 59'F OT to 39'F 3/4" 45 min. 1.5 hr. 24 hr. 1" 45 min. 1.5 hr. 24 hr. 40' 45' 50' 21 391/3162 134" 1.5 hr. 16 hr. 120 hr. Defoul 234" 8 hr. 72 hr. See Note 1 3" 8 hr. 72 hr. See Note 1 Note 1 For these sizes, the solvent cement can be applied at temperatures below 32'F, however, the sprinkler system temperature must be raised to a temperature of 32'F or above and allowed to cure per the above recommendations prior to pressure testing. PERMISSIBLE BENDING DEFLECTIONS SDR 13.5 (737) (ONE END RESTRAINED) PIPE SIZE inches LENGTH OF RUN (17.) IN FEET 2' 5' 7' 10' 12 15' 17' 20' 25' 30' 35' 40' 45' 50' 21 391/3162 11 33//1166 7/1 6 RELIABLE RC 49 Defoul - CPVC DROP L2 FIRE SPRINKLER CPVC DROP FIRE SPRINKLER PERMISSIBLE BENDING DEFLECTIONS SDR 13.5 (73T) (ONE END RESTRAINED) PIPE SIZE inches LENGTH OF RUN (L) IN FEET 2' 5' 7' 10' 12' 15' 17' 20' 25' 30' 35' 40' 45' 50' 21 391/3162 11 33//1166 7/1 6 RELIABLE RC 49 Defoul - 3" 0.4" 2.4" 4.6" 9.4" 13.5" 21.2" 27.2" 37.6" 58.8" 84.6" 115.2" 150.4" 190.4" 235.1" A AFCON 511 C.P.V.C. PIPE HANGER SIDE MOUNT MATERIAL: CARBON STEEL APPROVALS: UL AND CUL LISTED. FINISH: MIL. GALVANIZED, G-90 GOVERNMENT SPEC. PIPE SIZE A B C MAX. HANGER SPACING (FT) 3/4., (m) 3/4" (20.0) 561:2/2 (1.7) 1" (25.0) 6.0' (1.8) 134" 4331;186: 21 391/3162 11 33//1166 7/1 6 RELIABLE RC 49 Defoul SDR 13.5 (ASTM F442) HANGER SPACING NOMINAL SIZE MAX SPACING inches (mm) feet (m) 3/4" (20.0) 5.5' (1.7) 1" (25.0) 6.0' (1.8) 134" (32.0) 6.5' (2.0) 7/1 6 RELIABLE RC 49 Defoul FLOOR AREA: TOTAL LOT AREA= 1 1,530 SQ.FT. TOTAL MAIN FLOOR AREA=2,651 SQ.FT. NET TOP FLOOR AREA=1,836 SQ.FT. TOTAL FLOOR AREA= 4,487 SQ.FT. SOFFIT FORMULA MAXIMUM SPACING OF HEADS TO BE 18 X 18 AND 9' OFF WALL IN SINGLE HEAD ROOM MAXIMUM SPACING OF HEADS TO BE 16 X 16 AND 8' OFF WALL IN MULTIPULE HEAD ROOM • OWNER INFORMATION NAME RSVP REAL ESTATE, INC. ADDRESS 10900 NE 8TH ST, STE 1000 BELLEVUE, WA PHONE 206-244-1900 FIRE DEPT INFORMATION NAME TUKWILA FIRE DEPT ADDRESS 444 ANDOVER PAARK EAST TUKWILA, WA 98188 PHONE 425-481-8827 WATER DEPT. INFORMATION NAME ADDRESS PHONE WATER INFORMATON STATIC 75 RESIDUAL 20 GPM 4856 MAIN SIZE 8" SOURCE AS BUILT DRAWING TUKWILLA WATER DEPT BUILDING INFORMATION SQ. FT. 5146 SQ.FT. TYPE Wood Frame OCCUPANCY Residential LEGAL DESCRIPTION TAX PARCEL ID# 004200011 24=S • - 9 --Itt'. ''. f -----til .41 VICINITY MAT -41' NO SCALE WASHINGTON STATE CERTIFICATE OF COMPETENCY • FIRE PROTECTION SPRINKLER SYSTEMS 8 Edwin R Cogar 4295 -0499 -CG Level 3 • • 1111111111118111111118 PAID JUN --s 2016 4Cf6 fVot TUKWILA FIRE E NOTES REVISIONS SPRINKLER SYMBOLS SYMBOLS 0 SYSTEMS RISER o RISE UP o DROP DN L--7 2 WAY EARTHQUAKE BRACE ÷ 4 WAY EARTHQUAKE BRACE ICE GROOVED COUPLING \#01HANGER TYPE AND LOCATIO 0 UPRIGHT HEAD C) PENDENT HEAD t> SIDE WALL HEAD LEGEND OA UPRIGHT OVER PENDEN1 25 PIPE SIZING HYDRAULIC CALC NODE REVISION NUMBER El BRANCH LINE NUMBER NFAT> WELD TAG NUMBER DATE DESCRIPTION BY SYM CNT NAME METAL TEMP K NPT ORIF MFG. MODELif ESCUT CONN. 32 CONCEALED WHITE 1 60 4.9 1 /2" 7/1 6 RELIABLE RC 49 Defoul 37 TOTAL HEADS ON THIS PROJECT NOR 0 Fire Protection, Inc. PO Box 363 Ravensdale, WA 98051 425-432-7250 SIDHU HOMES 14816 46TH LANE S TUKWIIJA, WA 98178 CONTRACTOR: NORCO FIRE PROTETION, INC. PIPING PLAN AREA 1 PERMIT NO. CONTRACT NO. N16020 APPROVAL TUKWILLA FIRE DRAWN BY ED COGAR SCALE DATE REVISED PLOTTED 5/21/16 FP 1 of 1 E\„ : : CEPTE a sa Q) > C W� 2a� o 0 it0 O i OHO a t. cc,.4_, 0O C C.L, v C -cs p o C V1 41 4) �! v 7 '�— O �j -o rap U "O u N y' jfJ �`' 2 aE C4 a a��-� > 2t O ` ,n O F_. p C p CD U .� G( •- a5 }O� 6 •? q"s CO v U C u Q3 .0 u tri eK.i .0 •B°i— d1ocgm�'� �a v _ L N ., c) Q) .fl 0orc lot Ln u� �SQa. wmrav-arnCti> n 3a cw-ca 0 n''= C'` co 0 ❑ b p a C'01 C.) c cu- u� a n3 >,C 9 T2 ctT243: ipQ) (0 v 9 -0 ta In ac .c- 112 ot'r, I`3<ate-+ ir. LL -