Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 14408 46TH AVE S - UNKNOWN - PERMITS AND PLANS
14408 46TH AVE S ASSOCIATED PERMITS 97-5-285 D97-0046 TUKWILA FIRM DEPART/6T FINAL APPROVAL FORS[ Project Name l-- LL 2 7 SnY1 V o v\ v1 tZ Address /140S. 4*(- 1-1 r\N ..S Permit No. :09'1 - Ov I\16N Retain current inspection schedule Needs shift inspection Suite # Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Signature FINALAPP.FRM 510 I z4, 3b\ Date T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575.1404 • Fax (206) 575-469 City of Tukwila FILE John W. Rants, Mayor Fire Department Thomas P. Keefe, Rre Chief April 10, 1997 Fire Department Review Control #D97-0046 Re: Ellefson, Lavonne - 14408 46th Avenue South Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. For short plat development (four single family homes or less), hydrants shall be placed so that a hydrant is within 250 feet of a building. Distance from a hydrant to a building is measured along the path of vehicular travel. The hydrant must flow a minimum 1000 GPM with 20 PSI residual pressure. 2. Fire hydrants shall conform to American Water Works Association specifications C-502-54; it shall be compression type, equipped with two 2 1/2" N.S.T. hose ports and one 5" Storz pumper discharge port, and shall have a 1 1/4" Pentagon open -lift operating nut. 3. A11 required hydrants and surface access roads shall be installed and made serviceable prior to and during the time of construction. (UFC 901.3) 4. In lieu of a fire hydrant, an approved residential fire sprinkler system may be installed when vehicular travel distance from the nearest hydrant exceeds 250 feet. Acceptance of residential fire sprinkler systems shall include field verification of GPM and residual pressures meeting or exceeding the listing for the sprinkler type. 5. Your street address must be conspicuously posted on the building and shall be plainly visible and legible from Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 5754404 • Fax (206) 575-4439 City of Tukwila Fire Department Page number 2 John W. Rants, Mayor Thomas P. Keefe, Fire Chief the street. Numbers shall contrast with their background. (UFC 901.4.4) 6. Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance ##1742) This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. Yours truly, The Tukwila Fire Prevention Bureau cc: TFD file nod Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone (206) 575-4404 • Far (206) 575-4439 'DESIGN CALCULATIONS (NFPA 13D) RESIDENTIAL FIRE SPRINKLER SYSTEM Project Name: Project Location Available Water Sheet no. Date: By: of�_ cE6 1 PEN(,E. Floor Level: v / gT • (L414 Q (21 AJ(, S, Tv4il t lU ^ Elev. of Spkrs. D% iirLocation: C "re.12... Supply: SOI" g.p.m. at 495 p.s.i.: GQVi�-ro► Max. Sprinkler Spacing �p ft. X ft Sprinkler I D r-` 11-1 One -sprinkler design Min. flow rt g.p.m.: Min. pressure CZ" f p.s.i. Two -sprinkler design Min. flow IL g.p.m.; Min. pressure r 0 p.s.i. Type of piping: ,CPUC O PB U Steel (Sch. 40) O Copper K. L. M (circle one) CALCULATIONS 2 -sprinkler flow: System demand = g.p.m. CALCULATIONS 1`t 1 sprinkler flow: System demand = g.p.m. PIPING (1-spkr flow) TOTAL UNIT _ TOTAL DIA LENGTH X FR. LOSS FR LOSS t-ZC L(NC. W ' T$. =0L) t ► S C.PVC, I►" C.1 ,o344: 2_ ►o-1 FITTINGS & VALVES (1-spkr. flow) DIA &UNIT _ TOTAL UNIT __ TOTAL TYPE QTY. X EQ. LEN. — EQ. LEN. X FR. LOSS FR. LOSS -r1601 — _ _ 43S' ► 18 CIO° JQ_ 2 _7 ► 039 ► 85 1,A40,4 11 1.S ia.5 , 039 , 5b 1'Jn rr4 I' r J►I � ev<vtc 6,S METER FRICTION LOSS (size=3/4(C5g SPRINKLER PRESSURE REQUIRED ELEVATION HEAD LOSS (I 0 ft. X 0.433) TOTAL SYSTEM PRESSURE DEMAND TOTAL SUPPLY PRESSURE AVAILABLE PIPING (2-spkr. flow g.p.m.) ti -20 UN 1g' , 025'2. ,, 97 FITTINGS & VALVES (2-spkr. flow = p.m.) S ,6783 ,59 '10` /0 2t _ ,o78'3 f-r&v LL r,5' 14.er ,07g 1,29 C CL I " Lic.(c►Ftx..) METER FRICTION LOSS (size #44ii SPRINKLER PRESSURE REQUIRED ELEVATION HEAD LOSS ( 10 ft. X 0.433) TOTAL SYSTEM PRESSURE DEMAND TOTAL SUPPLY PRESSURE AVAILABLE C s7 /WIDER- t rki atrt ID r ,v r 'LAU: (5L:1 ,4-ri:• 2r 1)) .Ivvi l LKE N5 ZAuftovi Sr3r:M WitrusiottJ s‘Jrr ii V55-{ ter. (�rt� P1ALl i� v L6bL A©N 4 G'' N S citra 24 X 33 PRINTED ON NO. 1000H CLEARPRINT • A. _ )4 •.,. r•, • e. ACCEPTED 0 Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The TukwilS Fire 1 Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and ;;omissions which do not authorize violations of adopted -standards and ordinances. The responsibility for the ti adequacy of design rests totally with the designer. i Additions, deletions or revisions to these drawings after Ithis date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance Is subject to field test and inspection by The Tukwila Fire Prevention Burea Date: By: 4. •:FL , p- 1'1A N TUKWILA FIRE DEPARTMtN7 Please call: 575.4407 and give this job No. and exact address for shut- down or restoration approval. ALL. 7' f s r 1L.1"114C, COVIST: 2.1-110- 4 3 H' 4O Lbt`l* ,A\/ , ,, rry ,JILLA SCALE: I/_ C " APPROVED BY: DATE: JO.. Z/0+ 97 4(72 CL f -2..- 7k. 1 DRAWING NUMBER e)( at, -f r r, I-- • ;L IL LL-'1--- LILL4.41=2IL L LftIt4 L J ri i - i��►�' Fr_ -,. tr ir 1. 24 X 33 PRINTED ON NO. 1000H CLEARPRINT • A. _ )4 •.,. r•, • e. ACCEPTED 0 Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The TukwilS Fire 1 Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and ;;omissions which do not authorize violations of adopted -standards and ordinances. The responsibility for the ti adequacy of design rests totally with the designer. i Additions, deletions or revisions to these drawings after Ithis date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance Is subject to field test and inspection by The Tukwila Fire Prevention Burea Date: By: 4. •:FL , p- 1'1A N TUKWILA FIRE DEPARTMtN7 Please call: 575.4407 and give this job No. and exact address for shut- down or restoration approval. ALL. 7' f s r 1L.1"114C, COVIST: 2.1-110- 4 3 H' 4O Lbt`l* ,A\/ , ,, rry ,JILLA SCALE: I/_ C " APPROVED BY: DATE: JO.. Z/0+ 97 4(72 CL f -2..- 7k. 1 DRAWING NUMBER e)( at,