HomeMy WebLinkAboutPP - 14479 57TH AVE S - UNKNOWN - PERMITS AND PLANS14479 57TH AVE S ASSOCIATED PERMITS D16-0064 17-5-094 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /7-3— O, y PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: �� �� fC Fire Alarm: Type offI�Inspect'on: rlti Address:Contact Suite #: /�V7? 5-7 /fre Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: aci4veriai 01'2 Se,664--df Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: -, M/6- Date: eV/ W / i Hrs.: /- o $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Pro' : PilTr4CC(.._ tG T P -E3' Type of Inspection: co (lam-/vd—r Address: Suite #: S 4v-6-5 Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: flA4 c Date: h h Hrs.: ( $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Sheet Helton Fire 1 Date 05/17/17 Job: PATRICKK PROJECT INFORMATION Job Patrick Kent Res 14479 57th Ave So Tukwila WA Occupancy Area per Sprinkler Sprinklers Number of Sprinklers Calculated: Authority having Jurisdiction System type Wet Water Supply 60.00 psi Static, Light Hazard 256 sq ft 1616 Coverage Tyco LF -2 Concealed 4.9K 2 heads Tukwila Fire Dept 55.00 psi Residual @ 26.0 gpm Demand CALCULATION SUMMARY 22.74 psi @ 26.0 gpm @ B.O.R. 34.91 psi @ 26.0 gpm @ Supply 55.00 psi available @ 26.0 gpm Below curve by 20.09 psi PROGRAM: 'HydroCalc' by Micro Space Systems www.microspacesystems.com Pete Helton 1390-0601-A Level 1 lelton Fire Protection ��I,yy1FP965NC ea: Dat. PAID MAY 13 2017 TUKWILA FIRE cc ?.-0 0 o- 0 Of S 3 w 3c 3a a . � w a. Qaxl a- 11 11 gQi ?N O p i K O o a.52 0 col fA (A co C N N 0).7 WO) O O 0 O (PZ) tQ w =ma Pressure (PSI) o 0 O Q I I I I I 0 Sheet 2 8 m w Patrick Kent Res Sheet 3 Helton Fire Description of Fitting abbreviations Code Description PE Plastic 90 degree Elbow PTR Plastic Tee flow thru run BKF Backflow preventor MTR Meter Loss Description of Other abbreviations Code Description DR BL PT PE PF A.5 L F T Drop Branch Line Total pressure Pressure loss due Pressure loss due Raised to the power Actual pipe length Fitting equivalent pipe Total pipe length to elevation to friction of .5 changes (Square length Root) PATRICKK 05/17/17 0:45am Sheet 4 Helton Fire Srinkler Systems Hydraulic Flow Calculations Patrick Kent Res 14479 57th Ave So Tukwila WA Raw data previous to any calculations No. Code Diam Length Kfacl Kfac2 Press Elev Hose HW 1 DR1 1.109 2 DR2 1.109 3 BL1 1.109 4 RI1 1.109 5 UG1 1.109 0.50 4.9 7.000 -0.500 0.0 150 0.50 4.9 7.000 -0.500 0.0 150 27.00 DR1 DR2 0.000 -0.500 0.0 150 5.00 BL1 -4 0.000 12.000 0.0 150 60.00 RI1 -3 0.000 -0.500 0.0 150 Vel Fittings 32 1PE 32 1PE,1PTR 32 1PE,6PTR 32 2PE,4PTR,1BKF 32 4PE,1MTR PATRICKK 05/17/17 0:45am Sheet 5 Helton Fire Srinkler Systems Hydraulic Flow Calculations Patrick Kent Res 14479 57th Ave So Tukwila WA Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Drop 1 C = 150 L 0.5 PT 7.00 1 13.0=4.90(7.00)^.5 F 7.0 PE -0.22 (EL= -0.5 ft) 1 13.0 1.109 1PE T 7.5 0.02945 PF 0.22 4.3 PT 7.00 3 Bl Jct K -factor for drop 1 = 13.0/(7.00)".5 = 4.91 Drop 2 L 0.5 PT 7.00 2 13.0=4.90(7.00)^.5 F 8.0 PE -0.22 2 13.0 1.109 1PE 1PTR T 8.5 0.02945 PF 0.25 PT 7.03 3 K -factor for drop 2 = 13.0/(7.03)".5 = 4.90 4.3 C = 150 (EL= -0.5 ft) B1 Jct PATRICKK 05/17/17 0:45am Sheet 6 Helton Fire Srinkler Systems Hydraulic Flow Calculations Patrick Kent Res 14479 57th Ave So Tukwila WA Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Branchline No. 1 C = 150 -_____= K=9.81=4.91+4.90 L 27.0 PT 7.03 3 DR1 + DR2 26.0=9.81(7.03)^.5 F 13.0 PE -0.22 (EL= -0.5 ft) 3 26.0 1.109 1PE 6PTR T 40.0 0.10688 PF 4.28 8.6 PT 11.09 4 Top of Riser K -factor for branchline no. 1 = 26.0/(11.09)^.5 = 7.81 PATRICKK 05/17/17 0:45am Sheet 7 Helton Fire Srinkler Systems Hydraulic Flow Calculations Patrick Kent Res 14479 57th Ave So Tukwila WA Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes Riser C = 150 ____= L 5.0 PT 11.09 4 BL1 F 18.0 PE 5.20 (EL= 12.0 ft) 4 26.0 1.109 2PE 4PTR T 23.0 0.10673 PF 6.45 8.6 1BKF = 4.00# 1BKF PT 22.74 5 B.O.R. K -factor for Riser = 26.0/(22.74)^.5 = 5.45 Under ground C = 150 __= L 60.0 PT 22.74 5 B.O.R. F 28.0 PE -0.22 (EL= -0.5 ft) 5 26.0 1.109 4PE 1MTR T 88.0 0.10672 PF 12.39 8.6 1MTR = 3.00# PT 34.91 6 Supply Jct Available flow at 34.91 psi is 62.2 gpm which is 36.2 gpm from curve. Supply pressure available with 26.0 gpm flowing is 55.00 psi, thus system requirement is 20.09 psi below supply curve. (36.5%) PATRICKK 05/17/17 0:45am Sheet 8 Supply Analysis Node at Static Residual Available Total Required Source Pressure Pressure Flow Pressure Demand Pressure 6 60.00 = _ = _ = _ 55.00 26.0 55.00 26.0 34.91 Elevation Node Node (ft) K -Value Node Analysis Type Source 1 10.50 Orif= 4.90 2 10.50 Orif= 4.90 3 11.00 4 11.50 5 -0.50 6 0.00 _ Supply Pressure (psi) 7.00 7.00 7.03 11.09 22.74 34.91 Discharge (gpm) _ 13.0 13.0 _ Notes PATRICKK 05/17/17 0:45am Pipe Information Sheet 9 Nodel Elevl Kfactor Qadd Nominal Fittings L (ft) Cfac Total Pt Pipe (ft) Hose ID F (ft) Vel Elev Pe Node2 Elev2 Qtot Actual Length T (ft) Psi/Ft Fric Pf Notes 1 1 10.50 4.90 3 11.00 13.0 1" 1PE L 0.5 150 Pt 7.00 F 7.0 4.3 Pe -0.22 13.0 1.109 7.0 T 7.5 0.0295 Pf 0.22 DR1:K=4.91 2 10.50 4.90 13.0 1" 1PE 1PTR L 0.5 150 Pt 7.00 2 F 8.0 4.3 Pe -0.22 3 11.00 13.0 1.109 8.0 T 8.5 0.0295 Pf 0.25 DR2:K=4.90 3 11.00 9.81 [26.0] 1" 1PE 6PTR L 27.0 150 Pt 7.03 DR1 + DR2 3 F 13.0 8.6 Pe -0.22 4 11.50 26.0 1.109 13.0 T 40.0 0.1069 Pf 4.27 BL1:K=7.81 4 4 11.50 7.81 5 -0.50 [26.0] 1" 2PE 4PTR L 5.0 150 Pt 11.09 Top of Riser 1BKF F 18.0 8.6 Pe 5.20 1BKF = 4.00# 26.0 1.109 18.0 T 23.0 0.1067 Pf 6.45 5 -0.50 1" 4PE 1MTR L 60.0 150 Pt 22.74 5 F 28.0 8.6 Pe -0.22 1MTR = 3.00# 6 0.00 26.0 1.109 28.0 T 88.0 0.1067 Pf 12.39 Supply O Without Comments I(' As Noted in ReJ �, O Per The f';t�:ar�l . �d Letter _ .er These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted 5:andards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmit'cai of revised drawings for subsequent approval. Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: 5-- )--"S -1, By: 60 610 S.G.D. S.G. DINING RM. 7" DOUBLE `r 2x4 WALL LIMN RM. 42 Y HALF WALL UKWIL.A FIRE DEPAR iTMENT Please call 206-575-4407 and give this Fire. Permit No. /7- S- 091 and exact address for shut- down or restoration approval. EN GE Wl OD (VTO) ROVIDE THUR WALL COMBUSTION AIR VENTILATION SOLID CORE 134" ° IN. W/ WEATHER STRIP URFACE WARM WA L Y2G.W.B. WALLS .W.B. TYPE X LID FU L FURNACE & WAT R H + TER. MIN. 18" ABC] S "B 1 A/C PAD.I J TWO PERMANENT OPENINGS METHOD. • PROVIDE 1 OPENING COMMENCING WITHIN 12" OF THE TOP OF ENCLOSER & 1 OPENING COMMENCING WITHIN 12" OF THE BOTTOM OF THE ENCLOSER. rilt o . D S• • f1 e,clC4 4 FOR HORTIZONTAL DUCTS EACH OPENING SHALL HAVE A MIN. FREE AREA OF NOT LESS THAN 1 SQ. IN. PER 2,000 BTU/H. OF TOTAL INPUT RATING OF ALL APPLIANCE IN THE ENCLOSER. ENERGY CREDITS TABLE R406.2: 4x4 POST HIGH EFFICIENCY HVAC EQUIPMENT 38 AIR SOURCE HEAT PUMP WI MIN. HSPF OF 8.5. EFFICIENT WATER HEATING 5A - ELECTRIC WATER HEATER W/ A MINIMUM EF OF 0.93. AND ALL SHOWERHEAD AND KITCHEN SINK FAUCETS INSTALLED IN THE HOUSE SHALL BE RATED AT 1.75 GPM OR LESS. ALL OTHER LAVATORY FAUCETS SHALL BE RATED AT 1.0 4'-1O" AREA SUMMARY ........_..... ............. FIRST FLOOR AREA SECOND FLOOR AREA TOTAL FLOOR AREA GARAGE PORCH = HOSE BIB S.G. = SAFETY GLAZING " PAI'' MAY 18 2017 TUKWILA FIRE 7 M/ 6x10 D.F. #2 EGRESS BEDROOM 2 1',1 o„ DOUBLE STUDS 00M 4 w HANGER 1%1)(11 JOIST MUST LINE UP D I R E CTLY ABOVE WALL TO PROVIDE SHEAR TRANSFER. FASTEN JOISTS TO TOP PLATE WF (2) 10d NAILS c 12 O.C. (SEE DETAIL 3 ON liwomme IMINIIM =EP =filt C10201111 =I MOM imam MOM= Cellswil TRIPLE STUDS 6x6 POST 4x6 POST MAST R B DROOM 4x6 POST 5' TUB/ SHWR. SECON CANTILEVERED JOISTS FLOO "' RN