Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 13047 57TH AVE S - CARY LANG CONSTRUCTION / KNUDSON PARK LOT 2 RESIDENCE - PERMITS AND PLANS
13047 57TH AVE S ASSOCIATED PERMITS 16-5-216 D16-0191 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit ',Nee - olq \ 16-5--02{4 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Kn k5 Sprinklers: Z Hood & Duct: Type of InsRection: 2ki ,r s L Address: Suite #: ` � S� ► �� Co act Person: v\4eL Special Instructions: Phone No.: ?53 - Bqo --`)Mt) -4KLApproved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:` _ Ni-\ Date: i 1 /G( t--1, Hrs.: 1 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 3 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit Dib -b19 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: r/VV D' Goff Z Type of Inspection: SPIEuvidela e r Address: Suite #: /3047 $' .-Avz. 5. Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. nCorrections required prior to approval. COMMENTS: 5piivkJeits c"l- ra f A/‘ 7,4091-76,7) F-Ar»ii VYt 0 -e$ -Sr 01c r&I-e- l o 2 see73 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: 6054,--,h.) i Date: ///e1 J/6 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billin4 Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PJ6- 0// PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: �� Ati/2...._ Type of I pection: Address:,_ Suite #: /f0q, 6— Xz Contact Person: Special Instructions: Permits: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: //07- Inspector: aT Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: frt.- i6 l�-'� ' Date: f.007/ Hrs.: / 0 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 1,4- 5-21.6 PEIRMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: / �� �dI Sd �1 (-1771.21-1 Type of Inspection: alto Address: Suite #: /SO Li? S---7+11 %ick ) Contact 'Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. COMMENTS: /14. oaa Corrections required prior to approval. S-ez.• cc K 1 i � of / Pe r' arIiPp'Q . p 5 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: L Date: 1,A /a Hrs.: / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit D/b- orn( PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Sprinklers: Fire Alarm: TErf Inspection: Address: /.3a /4 7 Suite #: s---7 ti 1 -1Z- Contact Person: Special Instructions: Phone No.: Approved per applicable codes. f-r-6arrections required prior to approval. COMMENTS: No Le PIFs Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: A 1SY;-- 5"?..._ Date: 071 1,6 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Hydraulic Calculations for Project Name: KNUDSON LOT 2 Location: 13047 57TH AVE. S, , TUKWILA, WA 98178 Drawing Name: 80060_FP2.10_(FLOORPLANS) Design Remote Area Number: GARAGE Remote Area Location: GARAGE Occupancy Classification: Residential - 16X20 Commodity Classification: HOUSE 13D Density: 0.050gpm/ft2 Area of Application: 900.00ft2 (Actual 555.46ft2) Coverage per Sprinkler: 320.00ft2 Type of sprinklers calculated: Sidewall No. of sprinklers calculated: 2 Type of System: In -rack Demand: Hose Streams: Calculation Date: 10/11/2016 WET - CPVC Volume of Dry or PreAction System: N/A gpm at Node: N/A 0.0 gpm at Node: 1 Type: Allowance at Source Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 47.96 @ 47.697 Water Supply Information: Name of Contractor: RED HAWK FIRE PROTECTION LLC. Address: 801 VALLEY AVE SUITE D, PUYALLUP, WA, 98371 Phone Number: 253-840-9900 Name of designer: KYLE WHITT Authority Having Jurisdiction: CITY OF TUKWILA Notes: Automatic peaking results Left: N/A Right: N/A N/A WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Byron Richard Moye 9419-0815-c Red Hawk Fire Protection, LLC REDHAHF901QP M.E.P.CAD, Inc. AutoSPRINK® 12 v12.0.54.0 GARAGE 10/11/2016 2:36:13PM Page 1 Job Name: KNUDSON LOT 2 Date: 10/11/2016 Remote Area Number: GARAGE Water Supply Summary Sheet Node: 1 O O (NI fop f0 - -_ System demand curve Available Supply Static Pressure 70. 47.96 @ 69.976 0) (0 •r—• _ - co 0) = F. 111111111 111111111 1111111111(11111111 111111111 111111 111111111' m 111111 111111111 111 111 O O O 0) O O O O (0 0 O Isd - aJnssaJd 0 O 0 0 o (0 pO N 0 N O 0 10/11/2016 2:36:15PM AutoSPRINK® 12 v12.0.54.0 L&,©M.E.P.CAD, Inc. Job Name: KNUDSON LOT 2 Date: 10/11/2016 Remote Area Number: GARAGE BOR @ NODE 2 Summary Sheet O8 O N O �0 f0 _ — - _ System demand curve j�luuuniluiu111tI1iiiiiiii Available Supply Static Pressure 70. 0.00 @ 69.976 O 00) O r— CD LO() isd - ainssaid M 0 N O O O O ui 0 co O O 10/11/2016 2:36:15PM AutoSPRINK® 12 v12.0.54.0 �,®M.E.P.CAD, Inc. i99 Job Number: 80060 Report Description: Residential - 16X20 (GARAGE) Device Actual Flow Wpm) Minimum Flow (Qpm) K -Factor (K) Pressure (psi) C4! Sprinkler 220 23.00 b Most Demanding Sprinkler Data 23.00 4.4 27.324 �( ©M.E.P.CAD, Inc. AutoSPRINK®12 v12.0.54.0 10/11/2016 2:36:16PM Page 4 Job Name: KNUDSON LOT 2 Remote Area Number: GARAGE Date: 10/11/2016 Supply Analysis Node Name Static (psi) Residual Flow (Psi) (SW) Available Total Demand (Psi) (gpm) Required Pressure (Psi) 1 Water Supply 70.000 20.000 2966.00 69.976 47.96 47.697 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (Psi) Discharge at Node (gpm) Notes 1 -5-0 Supply 47.697 47.96 220 8-6 Sprinkler 27.324 23.00 221 8-6 Sprinkler 32.191 24.96 3 0-6 37.677 93 1-8% 37.087 95 3-1 36.398 98 5-2% 35.439 L© M.E.P.CAD, Inc. El AutoSPRINK®12 v12.0.54.0 10/11/2016 2:36:17PM Page 5 Job Name: KNUDSON LOT 2 Remote Area Number: GARAGE Date: 10/11/2016 Pipe Information Node 1 Elev 1 (Foot) K -Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (PO and shown as a negative value. Fitting (Foot) Pf Friction Loss Per Unit (Psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 220 8-6 4.4 23.00 1 (See Notes) 14-3 150 27.324 Route 1 Sprinkler, 5E(7-0), C(5-0), Tr(1-0) 41-0 0.088117 221 8-6 23.00 1.1010 55-3 4.867 221 8-6 4.4 24.96 1 (See Notes) 3-3%z 150 32.191 Sprinkler, b(1-0), cplg(1-0) 2-0 0.343214 1.430 98 5-2% 47.96 1.1010 5-3 '/z 1 818 98 5-2% 2 (See Notes) 2-1''/ 120 35.439 2f(-0.000) 0.017696 0.921 95 3-1 47.96 2.2030 2-1% 0.038 95 3-1 1% (See Notes) 1-2 120 36.398 BaIV 0.081491 0.595 93 1-8% 47.96 1.6100 1-2 0.094 93 1-8% 1%1-2% 150 37.087 0.055931 0.522 3 0-6 47.96 1.5980 1-2% 0.067 3 0-6 11/4 (See Notes) 62-2'/s 150 37.677 E(8-0), CV, S 8-0 0.108770 2.384 1 -5-0 47.96 1.3940 70-2% 7.637 47.697 Total(Pt) Route 1 L© M.E.P.CAD, Inc. AutoSPRINK® 12 v12.0.54.0 GARAGE 10/11/2016 2:36:19PM Page 6 Job Name: KNUDSON LOT 2 Remote Area Number: GARAGE Date: 10/11/2016 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) ` LC Value Multiplier Actual Inside Diameter 4.87 = Factor Schedule 40 Steel Pipe Inside Diameter Value Of C 100 130 140 150 Multiplying Factor 0.713 1.16 1.33 1.51 Fittings Legend ALV Alarm Valve AngV Angle Valve b Bushing BaiV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DeiV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 11%° Elbow Ee2 221h Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow flg Flange FN Floating Node fT FireLock(TM) Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Tum Elbow mecT Mechanical Tee Noz Nozzle P1 Pump in P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Tum 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap M�,© M.E.P.CAD, Inc. AutoSPRINK® 12 v12.0.54.0 GARAGE 10/11/2016 2:36:18PM Page 7 0 5 10. 20 . SCALE 1"=20'-0" HYDRAULIC NODE GATE VALVE-N.R.S. (GV) ELECTRIC BELL .EXISTING SPRINKLER PIPING NEW SPRINKLER PIPING BY OTHERS NEW SPRINKLER PIPING BY APFP RED HAWK FIRE PROTECTION, LLC (RHFP) WILL PROVIDE ONE WET PIPE AUTOMATIC SPRINKLER SYSTEM TO PROTECT THE NEW RESIDENCE. RHFP WILL START WORK AT EXISTING 11/2" UNDERGROUND SUPPLY LOCATED IN THE BASEMENT MECHANICAL ROOM. ALL AREAS PROTECTED BY A WET SYSTEM MUST BE MAINTAINED BY OTHERS AT A MINIMUM 40°F TO PREVENT FREEZING. EXCLUSIONS PAINTING OR LABELING OF PIPE AND/OR EQUIPMENT ELECTRICAL WIRING OF ANY KIND INCLUDING BUT NOT LIMITED TO WATERFLOW SWITCH, ELECTRIC BELL, AND TAMPER SWITCHES CENTRAL STATION MONITORING EQUIPMENT, WIRING AND SERVICES CEILING AND WALL REMOVAUREPLACE TO FACILITATE THE INSTALLATION OF THE SPRINKLER SYSTEM. 801 VALLEY AVE NW, SUITE D PUYALLUP, WA 98371 PHONE: (253) 840-9900 FAX (800) 591-4382 WA CL# REDHAHF9010P RHFP START POINT ® 0-6 AFF NEW 1" WATER METER BY OTHERS NEW CITY CONNECTIO BY OTHERS 1. SPRINKLER SYSTEM DESIGN PER NFPA#13D 2010. 2. ALL MATERIALS SHALL BE NEW AND UL AND/OR FM APPROVED.' 3. FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH NFPA#13D (2010) AND SPECIFICATIONS. 4. IN LOCALITIES SUBJECT TO FREEZING CONDITIONS IT IS THE OWNERS' RESPONSIBILITY TO PROVIDE HEAT. THROUGH OUT THE WET PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE, DELUGE AND OTHER TYPES OF VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS. 5. FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE SPRINKLER SYSTEM OR ANY APPURTENANCES THEREOF. 6. ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING OR PATCHING TO BE BY OTHERS. 7. ALL PIPING IN RESIDENTIAL UNITS TO BE CPVC PIPE. 8. ALL THREADED PIPE TO BE SCHEDULE 40 BLACK JOINED WITH CAST IRON THREADED FITTINGS: 9. ALL WELDED PIPE TO BE SCHEDULE 10 BLACK JOINED WITH GROOVED FITTINGS. 10. ALL GROOVED COUPLINGS TO BE RIGID. UNLESS NOTED OTHERWISE. 11. SEE FP 1:10 FOR SYSTEM STANDARD DETAILS. 12. ALL HANGERS FOR CPVC ARE TO BE PER DETAILS ON SHEET FP 1.10 (UNO). 13. ALL HANGERS FOR STEEL PIPE TO BE NO. 15W SAMMY SIDEWINDER (UNO) 14. ALL PIPE DIMENSIONS ARE CUT LENGTHS (UNO) 15. ALL DRY MAIN PIPING TO BE SLOPED AT 1/4" PER 10'-0" AND ALL DRY LINE PIPING TO BE SLOPED AT 1/2" PER 10'-0". - ,WASHINGTON STATE •' ' ti • CIRTIPICATE o0 COMreTI9NCY . i rime rfOTECTION SPRINKLER SYSTEMS:: al:. i Byron Richard Moire k 9419-0$15-c i Red Hawk Fire. Protection,' LLC 1 . REDHAHF901QP r • 010/13/2016 Expires • : 8ignat .. • ;Data,. !'. 12II1H8 II •---rr--rrr----rr.---rrtr- ----i PER NFPA 13D (2013), CITY OF TUKWILA. RM -01 (RESIDENCE) WET SYSTEM RESIDENTIAL DESIGN DENSITY: MOST DEMANDING 2 HEADS 16x20 MAX SPACING 23GPM/SPRINKLER PER MANUFACTURER Approvals Required. ' CITY OF TUKWILA OWNER / ARCHITECT Revisions • 29815 24TH AVE. SW FEDERAL WAY, WA 98023 CONTACT: CARY LANG Phone: 206-423-5055 Fax: TO SYSTEM WATER FLOW INFORMATION HAS BEEN PROVIDED BY TUKWILA WATER DEPARTMENT. STATIC PRESSURE: 120 PSI RESIDUAL PRESSURE 20 PSI RESIDUAL FLOW: 2966 GPM Contract Name: SPARE CABINET TUKWILA 4/ILA FIRE DEPARTMENT pleesn - ,i&C,:!06-5754407qry' and .�itii this Fire r Permit NO. 7 r approval. 14 .1 10 kft(11 Rk ROW (L') 1-�E-1r- y q iil-Jt - 2 X 1%" REDUCING COUPLING TYP 1" MALE CPVC ADAPTER TYP BASE OF RISER AT NODE 2: FP 0.10 ` SITE PLAN AND NOTES FP 2.10 FIRE SPRINKLER PLAN 13047 57TH AVE. S TUKWILA, WA 98178 Drawing Title SITE PLAN AND NOTES lt�r 1 r [TYP. CONC. SPRINKLER HEAD so1057,WOM 11.20t1- i') l rr j rf•. �[) i 1{1 .5 1t 1X ('.,.Yr i i) if )tfr7 `t`(r'. =I I ISI I I—i i �-111 III, ,III, ;III—III=III= MAINTAIN 1 ii" ANt� Jt—tt�t=1 CLEARANCE AROUND PIPE UTILITY MASTEN OATH TUTU'. TU'.. FLOC/ SCALE 1/2"=l'-0" 41:11:ii'i1Q lig i1 \l, \TYP. SPRINKLER PIPE RISER MATERIAL LIST Days tor Sash! South Tukwila'. ITEM # Witho lt. r. t As NoteL 0 Per The i'E icaci ie Letter -1-hese plans ha"e been reviewed by Ihe Tukwila Fire T MAI Prev: ndion Bureau tf3r conformaii,J7 with current City starndardis. Acce rli:t' is sub1eC ::-'fors and omissions which r;i.a not aluthori, -,k016tions of adopted : tF nclardS and r r s : Tnr2 { 12 ;oor,-ihillty for the ii 1s'.iiilclC�/ C` .;.. atallt; designer. Additions: de e'io' 'u) ;It1nS kr rhes drawings after this date `acceptance and mil require a resubrnitY drawings f r approvz!, OARAtuSte Final accer. , : 61Joject Co field test and inspection by The Tukwila ieventien Bureau. Date: Jo 14/ - l L By: o I floor, FLOOR CONSTRUCTION, 3/4' TIO PLYWOOD eUE-PLIt G UEP ♦ NAILED TO ( EE PAWNS PIAN FON SIZE AND SPACING) �. te-eo IN LLAT1ON DESCRIPTION. 1 1 1 Y TxT BALL VALVE 2 1 1 • POTTER VSR WATERFLOW SWTICH 3 1 6 POTTER PBA246 4 1 61 -id SPARE HEAD CABINET CONTAINING: F'0Pi_Sitarmet r oasis SPARE HEAD CABINET GRAWI»SPAC BUILDING CROSS SECTION SCALE NTS DESCRIPTION Date: Job Number:. Designer: Building Permit: 4 % GL4906 RESIDENTIAL. SPRINKLER HEADS 155° 1 1/2 GL5606 CONCEALED SPRINKLER HEAD 175° 1 YP GL4231 QR SIDEWALL SPRINKLER HEAD 155° 1 SPRINKLER HEAD WRENCH FOR GL4906 1 SPRINKLER HEAD WRENCH FOR G15606 1 SPRINKLER HEAD WRENCH FOR G14231 ``gam 6L6 C+ . I 1 201: 4s-75-1:5 d N'';t! TUKWILA FIRE 1 FP 0.10 roster Uoll Litik IRE PROTECTION, MASTl P PATH 1. ALL CEILINGS TO BE 8-0 UNO 2. ALL PIPE TO BE 1" CPVC UNO COVFP -12 PATIO 3. SPRINKLERS OMITTED FROM ALL CLOSETS MEETING THE REQUIREMENTS OF SECTION 8.6,3 OF NFPA 13D (2013) AREAS MARKED WITH HATCH 4.. SPRINKLERS OMITTED FROM ALL BATHROOMS UNDER 55 FT2 PER SECTION 8.6.2 OF NFPA 13D (2013) AREAS MARKED WITH HATCH GaA1" POOM 1. ALL CEILINGS TO BE 9-0 UNO 2. ALL PIPE TO BE 1" CPVC UNO 3. SPRINKLERS OMITTED FROM ALL CLOSETS MEETING THE REQUIREMENTS OF SECTION 8.6.3 OF NFPA 13D (2013) AREAS MARKED WITH HATCH 4. SPRINKLERS OMITTED FROM ALL BATHROOMS UNDER 55 FT2 PER SECTION 8.6.2 OF NFPA 13D (2013). AREAS MARKED WITH HATCH MINIMUM DISTANCES FOR ORDINARY -AND'' INTERMEDIATE -TEMPERATURE RESIDENTIAL SPRINKLERS (NFPA 13D-2002 TABLE 7.5.5.3) MA5TEP SGC) O OM CL.O'I:i Aux Remote Area Remote Area MASTER BEDROOM OCCUPANCY CLASSIFICATION Residential - 18X18 TOTAL HEADS FLOWING " 2 TOTAL WATER REQUIRED 34.48 TOTAL PRESSURE REQUIRED 35.243 BASE of RISER (gpm) 34.48 BASE of RISER (psi) 28.712 SAFETY MARGIN (psi) +34.744 (49.6%) HEAT SOURCE MINIMUM DISTANCE FROM EDGE OF SOURCE TO ORDINARY SPRINKLER (INCHES) 2301 E:PIONEER AVE. 'SUITE $.... PUYALLUP,' WA 98372 PHONE: (253).840-9900 FAX (800) 59:1-4382: MINIMUM DISTANCE FROM EDGE OF SOURCE TO INTERMEDIATE - SPRINKLER (INCHES) SIDE OF OPEN OR RECESSED FIREPLACE FRONT OF RECESSED • FIREPLACE KITCHEN RANGE • Approvals Required CITY OF TUKWILA d OI ; r�r�.iri�ri wrrrrr rrwri�'rrrrrlll l�� ., WASHINGTON STATE! r • CERD TIFICATE r COMPETENCY I mite PROTECTION SPRINKLER SYS: STEMI • Byron Richard Moye I 9419-0815-a_' M Red Hawk Fire protection, LLC " ■ REDHAHF901QP � ,,•</ 10/13/2016 �,)expl es I Signa% Date • ;L1M31/18 -YrwrrrwwYIN --rrrIno --- ger -- maws -- HOT AIR FLUES UT11..ITY UNINSULATED HOT WATER PIPES SIDE OF CEILING- OR WALL- MOUNTED HOT AIR DIFFUSERS FRONT OF WALL- MOUNTED HOT AIR DIFFUSERS HOT WATER HEATER OR FURNACE CHI=N LIGHT FIXTURE: OW -250W LIGHT FIXTURE: 250W -499W Revisions 1 - 01.13.15 Revisions to make flow system PAN1I?Y I3 .PI OOM Or'EN rg I3rLOW Caution: It is important that the insulation be installed tight against the joists: In unheated areas, any spaces or voids between the insulation and the joists causes the water in the fire sprinkler piping to freeze. . CONNECT TO ,[TOILET 29815 24TH AVE. SW FEDERAL WAY, WA 98023 CONTACT: CARY LANG Phone: 206-423-5055 PLAv POM 5/'1 PATH Contract Name: Hydraulically Most Demanding Area Remote Area GARAGE OCCUPANCY CLASSIFICATION TOTAL HEADS FLOWING TOTAL WATER REQUIRED Residential - 16X20 2 47.96 TOTAL PRESSURE REQUIRED 47.697 BASE of RISER (gpm) 47.96 BASE of RISER (psi) . 37.677. SAFETY MARGIN (psi). +22.278 (31.8%) Caution: For areas having temperatures of 0°F (-18°C) or lower, an additional batt of insulation covering the joist and the fire sprinkler piping should be used. If this is not done,` freeze -ups can occur in the sprinkler piping, 13047 57TH AVE. S TUKWILA, WA 98178 COVEPEI7 PORCH Drawing Title FIRE SPRINKLER PLAN FIRE SPRINKLER PLAN MAIN FLOOR SCALE 1/4"=1'-0" SCALE 1/4"=1'-0" HANGER FIG. 186. HANGER FIG. 188. 1 1/2" FIG. 126 /. LAG BOLT FIG. 126 LAG BOLT HANGERS - PIPE HANGERS SHALL BE SIZED, SPACED AND INSTALLED AS REQUIRED BY NEPA STANDARDS NO OTHER PIPING AND/OR DEVICES ARE TO BE ATTACHED TO THE SPRINKLER PIPE HANGER SYSTEM UNLESS THE HANGER HAS BEEN SPECIFICALLY DESIGNED FOR THE ADDITIONAL LOADING. - THIS CONTRACT DOES NOT INCLUDE ANY MATERIAL OR DEVICES TO IMPROVE THE STRUCTURAL STRENGTH OF THE BUILDING TO ENABLE IT TO CARRY THE LOAD OF THE FIRE PROTECTION SYSTEM. SEE DETAILS ON THIS SHEET FOR THE SPECIFIC HANGER ASSEMBLIES USED FOR THIS INSTALLATION. NFPA 13, 2010 Edition Table 9.2:2.1 MAXIMUM DISTANCE BETWEEN HANGERS (ft - in) NICET Stamp. WOOD JOIST OR ----- COMPOSITE "COMPOSITE WOOD JOIST WOOD TJI/ROOF TRUSS Sprinkler Legend Symbol Manufacturer Response Type SIN K -Factor Size Temperature Finish Escutcheon Spacing Discharge Quantity E) Globe Quick Pendent GL4906 4.9 1 155°F Bronze CONC 20X20 20GPM 1 Globe Quick Pendent GL4906 4.9 'A 155' F Bronze CONC 16X16 13GPM 18 Globe Quick Pendent GL5606 5.6 'A' 175°F Bronze CONC 225 SQ ST N/A 1 ( Globe Quick Pendent GL4906 4.9 'A 155°F Bronze CONC 18X18>. 17GPM 3 1 Globe Quick Sidewall GL4431 4.4 'A 155°F Bronze REC 16X20 23GPM 2 Total = 25 NOMINAL PIPE SIZE ( IN. ) 3/4 1 1 1/4 1 1/2 .2 . 2 1/2 3 5-6 6-0.' 6-6 7-0 8-0. 9-0 10-0 Date: Job Number: Designer: Building Permit: Drawing No.