HomeMy WebLinkAboutPP - 6801 s 180TH ST - UNKNOWN - PERMITS AND PLANS6801 s 180TH ST ASSOCIATED PERMITS 08-5-398 17-F-053 11-F-253 07/31/2008 09:09 FAX 4252516960 EMERALD FIRE 1002/002 emerald EtreaL313% Fire Sprinklor SpcclQlista JOB NAME: CARLYLE INC. ADRESS: 6801 SOUTH 1501 ST. TUTKWLLA, WA 9818 'ACCEPTED Existing offices were refigured to turn two offices Add new brass'" 155 deg. Globe pendant sprinkl office. Tee off exiting 1" drop in adjacent office. 11021 Cramer Rd. KPN • Without Comments As N ted In Red 401 WOW PAYE' Letter i nese plans have been reviewed by The Tukwila Fire n 'on Bureau for conformance with current city standar s. Acceptance is subject to errors and omissions which do of authorize violations of adopted n. • rain noes. The responsibility for the ign rests totally with the designer. ons1or revisions to these drawings atter acceptance and wilt require a drawings for subsequent approv stance adequ Additio this da resub Final a. _''r; "*�* �. ubject to field test and inspection The Tu. - : P : vention Bu .Date: /I �i ,!v By: 900 j I UKWILA FIRL Utt'r,rc �w::ir{ Please call: 575-4407 and give this job No. o 5 396 and exact address for shut• or restoration aporowat V+ Gig Harbor, WA 98329 • Office (263) 857-2056 • Fax (253) 857-2312 • Local 699 Contractor Security Solutions Stanley Convergent Security Solutions, Inc. 2700 Richards Rd. Suite 202 Bellevue, WA 98005 November 14, 2011 City of Tukwila Al Metzler 444 Andover Park E Tukwila, WA 98188 Fire permit: Carlisle Interconnect Technologies Location: 6801 S 180th Street Tukwila, WA Scope of work: This location has up graded the HVAC unit to a larger unit. It went from a 2 ton to 5 ton unit. The old unit had a duct detector that was connected to the existing fire panel on a supervisory point. When the old unit was removed and the new unit installed we need to reconnect the wires to the new duck detector for monitoring. We need to reestablish the connection to the existing fire panel. After the connection has been made and tested we will call for final inspection and sign off. . Howard Richardson 425-957-7025 Fax: 425-746-0084 hichardson@stanleyworks.com TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Pe;'mit No. and exact address forshut- down ut- down or restoration approval. No print is needed for this scope of work because the only change is a HVAC unit up grade. Please call Howard Richardson for any additional i Howard Ri Stanley Security 425-957-7025 howard.richardson@sbdinc.com NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing, TED , f wit': '' t Comments O n Rad p Pc, ; ne Attached Letter ---z. plans have beer- reviewed hal The Tukwila Fire r cion bureau for amforrna"'ce with current City arils. ACCCDtECE is sub_e i to r.rrors and --erns whirr, o+:. ,;roarions of adopted aarcis and The ; esoorsiniiity for the J.:.+acy of o° -.,:,r •(e.7•(est.7 totaiiv -wor; the ,;:signer. 'CTs, deieti t V,)'] -11:-.;e drawings afte , f require a of revised drawings for suosequent approval. =final acceptarice !s suclect to field test and inspection by The Tukwila Fire Prevention Bureau. Date: //-15-- / ( By: sl t7 S 0 N 0 O -t CV O O o O V/ N_ 0 u). fl. O O N O V/ N_ co 0) CV 0 0 O N O V/ N_ 4t CO 0 O. 00 t!) tV 0 0 O O VJ N_ O O O VJ N_ O O O 0. E c 1 1- co co 0 ti O. O 5495 Pwr Module O O 0 O 5495 Circuit 1 O O O O. 5495 Circuit 2 O O O. O. 5495 Circuit 3 T O 0 0 O .1:igli15495 Circuit 4 0 0 O 54 to: 1: aec 0) uto G .0 E 0 :SSS i3Gt g Configure Circuits i IN' ,Ii(';\:1.111' Circuit Configuration Project Information Project Name: Vietnamese Martyers Church Prepared By: Matt Thawsh Project ID: 0 Date: 3/1/2017 DevjQe System Sensor S/SC Strobe (110cd) ................................ netts 5495 Circuit Corm ............................ :,:!%000.:POKR404igurterzt t?raw Totat '_: Standby ...Malty, .. :Standl y Alarm s; 0,000:: 0 000 (1202 ..: 0.202 5 System Sensor S/SC Strobe (75cd) 0 000< €58 0790 2 8 System Sensor S/SC Strobe (30cd) System Sensor S/SC Strobe (15cd) 1.091 t 000 !(. 0,066 0.1 0 528 0000 tf <, 0 3 Name: 5495 Citcutt.2€ System Sensor S/SC Strobe (110cd) Totals Max Circuit Current 1708 Ctlrretit i kaw Each tirr It Draw i QtaI Standby Alarm . $tarydby Alarm,,:;;:;; 0 000 2 System Sensor S/SC Strobe (75cd) 0000. 0.1;58 5 4 System Sensor S/SC Strobe (30cd) .::.::.;0.00 0'::.:.::.; ......................... 375:::>` .............. Unused 0000! .......................... 0:000 ...................... 06.... aggt00.Q1jR ...................... pt Name,.] 5Circuit 3 ........................ . Panel ID ax Circuit Totals 0.000 298 Curr rit Draw Each, Current trawTotat < Standby Alarm Standby Alarm System Sensor S/SC Strobe (115cd) 0.210 NiXfating 4 System Sensor S/SC Strobe (110cd) 0:000: .............. epi O Unused 0,01w.. Unused 0000 ......................... 1 ;11000 6 .300 0 000 0000 Totals 0.000 1.018 ................... Qtv Dev4ce< : anent C Indby aw Each t[rrent Draw Total; t Afarm, Starry Alarm :' 4 System Sensor S/SC Strobe (110cd) 001N:N 808 3 System Sensor S/SC Strobe (75cd) ditrObigi 0474 4 System Sensor S/SC Strobe (30cd) I Ori: 0 000 Unused O ti00 X000.. 0.000 0.000 >; 0 000 000 <! Totals 0.000 1.658 5495 ............................. . ............................... ................................ rctht CLUTeni. 3 Amis ae Gtrtfe t f raw: actr Got ant t:3 4. Tngli .>> Standby Arm ... .Stat d y Alarm <; Unused El 00Q .......................... t1i300:> ..................... Unused .......................... Unused Di Unused >0 000 (3000 ; 0400 Totals 0.000 :.. •:: 0'000 DRAWING DIRECTORY (SHEET #: SHEET TITLE: FIRE ALARM CONTROL PANEL ITEM .CVR COVER SHEET, BILL OF MATERIALS AND GENERAL INFORMATION FA1 SOUTH FLOOR PLAN FA2 NORTH FLOOR PLAN FA3 SANCTUARY FLOOR PLAN FA4 ELECTRICAL SCHEMATIC & BATTERY CALCULATIONS MANUAL PULL STATION CONSULTANTS PROJECT NAME: VIETNAMESE MARTYRS FIRE ALARM AND VOICE EVACUATION SYSTEM 6801 S 180TH ST. TUKWILLA, WASHINGTON 98188 FIRE ALARM SUPPLIER: INFINITY FIRE PROTECTION 17701 108TH AVE SE #426 RENTON, WASHINGTON 98055 PHONE: (206) 381-3090 WWW.INFINITY-FIRE.COM REFERENCES: NFPA 70 NATIONAL ELECTRICAL CODE NFPA 72 NATIONAL FIRE CODE UL -864 AND OTHER APPLICABLE STANDARDS COMPLETE FIRE PROTECTION SYSTEM, UL LISTED CONFORM TO REQUIREMENTS OF NFPA APPLICABLE SECTIONS THE AMERICAN DISABILITIES ACT (ADA) ABBREVIATIONS 0 MOUNT NOTIFICATION DEVICES 80" ABOVE FLOOR OR 6" BELOW CEILING, WHICHEVER IS LOWER, PER ADA REQUIREMENTS. "T". BAR CEILING -36" MAX. DIFFUSER DOOR OUTSIDE OF ROOM FIRE EVAC PANEL A f NOT LESS THAN 3 - NOT MORE THAN 4'-6" 7/ 72" ANN BOTTOM OF LENS NOT LESS THAN 80" AND NO GREATER THAN 96" (7.5.4) 48"-60" FINISHED FLOOR STANDARD MOUNTING HEIGHT DETAIL VIETNAMESE MARTYRS 6801 S. 180TH ST. TUKWILLA, WASHINGTON 98188 FIRE ALARM AND VOICE EVACUATION SYSTEM BUILDING PERMIT: D13-175 REVISION: 0 SCOPE OF WORK: Adding (5) five speaker strobes to existing building fire alarm system. Devices are to be added in Classrooms that were previously designated as Offices. Area of work is the outlined area on sheets; FA -1 anc1 EA -2. Revised battery calculations are provided with the submittal documents. El Without Comments O• As Noted in Red Per The Attachedletter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance e s subject rp .,Tors and omissions which not authorize Ioiations of adopted standards and oro 3TCPS The responsibility for the adequacy .of desqr P.15 totally ‘n,:tn Ei e designer, Additions; -zwisions ra rhe drawings after this aacE th cceptance and will require a r•esuhmirca3 .:v.,se,..ctrawings for subsequent approval. Final acceptance i's; subject to field test and Inspection by The Tukwila Fire Prevention Bu eau. ` Dater "11 ' / 7 By: TUKWILA FIRE DEPARTMENT T Y Q #' m ! i 205-575-1407 aT3nd g vt this Fire Permit No. and exact ddrr ;s --for- ut• - down or r 1-� on approval. CONDITION o Qo Q QJCD -0) SEQUENCE OF OPERATIONS 0) FAC P FUNCTIONS m� 0 w� �o J= CD - L Q ��m v tti Q 0 .. O Z ku J Z 7. Z' Z v v QJ ci V JAN Q c7 : /I.:, /:::---,Cr ) /,‘,..._:-..C‘) 00 S v V c) /''i j-1....::...,.--- o Q' 7 v 0) A B C DEFG H STANDBY CONDITION 2 SYSTEM TROUBLE CONDITION 0 0 • 3 SMOKE DETECTOR • • 0 • • 4 PULL STATION 0 0 • • 0 5 WATER FLOW 0 0 • • 0 6 SPRINKLER TAMPER 0 0 THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OF INFINITY FIRE PROTECTION AND ALL RIGHTS ARE EXPRESSLY RESERVED. IT IS SUBMITTED UNDER A TRUST RELATIONSHIP FOR YOUR USE IN CONSIDERING THE PURCHASE OF THE EQUIPMENT DESCRIBED HEREON FROM INFINITY FIRE PROTECTION. THIS DRAWING IS NOT TO BE USED FOR ANY OTHER PURPOSE NOR COPIED IN WHOLE OR PART NOR ITS DESIGN FEATURES USED IN OTHER PRODUCTS WITHOUT OUR WRITTEN CONSENT. IT IS TO BE RETURNED WHEN NO LONGER REQUIRED, OR UPON REQUEST. 0 j •:h. cO rj 0 W 0O I O LIJ 1:)s) 'DOT_ HZ I z. o0: wZw N _ ELI- CT l C..AL NOTES.. SITE MAP THE CONTROL PANEL REQUIRES 120 .VAC, 50/60 HZ, 5 AMP MAX. POWER TO THE CENTRAL PANEL MUST BE A DEDICATED CIRCUIT W/LOCKING BREAKER BY OTHERS. THE 2. ANY EQUIPMENT LOCATION CHANGE FROM THAT SHOWN`Ott DRAWINGS REQUIRES PRIOR APPROVAL. WIRE RESISTANCE FOR DETECTION CIRCUITS • MUST NOT EXCEED 20 OHMS (APPROXIMATELY 3000 FT. OF 18 AWG OR 7700 FT. OF 14 AWG WIRE). 3. DETECTOR, ALARM AND DISCHARGE CIRCUITS ARE SUPERVISED AND MUST BE CONNECTED AS SHOWN. NO PARALLEL CIRCUITS. 4. ALL LOW VOLTAGE SUPERVISORY WIRING FOR EACH ZONE MUST BE SHIELDED FROM, ALL OTHER WIRING. 5. ALL CONTACTS ARE ,RATED AT 1.5 AMP, 120 VAC/2p \VDC. 6. WIRE RANGE FOR TERMINALS IS 14 AWG TO 18 AWG. TWO WIRES ON THE SAME TERMINAL MUST NOT DIFFER BY MOR THAN TWO. GAUGES. .__COMPLIANCE LTH AI. L LOCAL ,WIRING _CODES IS REQUIRED. 7. DO NOT CONNECT DISCHARGE DEVICES TO PANEL. SERVICE TECHNICIAN WILL DO TIE-INS AT FINAL CHECKOUT. 8. 120 VAC SUPPLY AND 24 VDC BATTERY STANDBY MUST BE DISCONNECTED BEFORE PERFORMING ANY TYPE OF SYSTEM MAINTENANCE. ALLOW 30 SECONDS AFTER POWER DISCONNECT BEFORE PERFORMING MAINTENANCE. 9. BATTERY STANDBY TOWER IS PROVIDED FOR THIS SYSTEM. 10. END OF LINE RESISTORS ARE INCLUDED WITH THE PANEL. FACP FIRE ALARM CONTROL PANEL ITEM PART NUMBER AMP VOICE AMPLIFIER PANEL SNAG SUPPLEMENTAL NOTIFICATION PANEL FACP P MANUAL PULL STATION 1 FIRE ALARM CONTROL / VOICE EVACUATION CONTROL PANEL H/S HORN STROBE 2 EVS-50W _rl ANN REMOTE FIRE ALARM ANNUCIATOR SNAG MM MONITOR MODULE 1 SUPPLEMENTARY NOTIFICATION APPLIANCE CIRCUIT PANEL RM RELAY MODULE SK—MONITOR-2 5 RM RELAY MODULE 5 SK—PULL—SA SCM SUPERVISED CONTROL MODULE gil 6 SD SMOKE DETECTOR SPEAKER/STROBE. (WALL MOUNT) X. WP WEATHER PROOF 6 t ® I 0 MOUNT NOTIFICATION DEVICES 80" ABOVE FLOOR OR 6" BELOW CEILING, WHICHEVER IS LOWER, PER ADA REQUIREMENTS. "T". BAR CEILING -36" MAX. DIFFUSER DOOR OUTSIDE OF ROOM FIRE EVAC PANEL A f NOT LESS THAN 3 - NOT MORE THAN 4'-6" 7/ 72" ANN BOTTOM OF LENS NOT LESS THAN 80" AND NO GREATER THAN 96" (7.5.4) 48"-60" FINISHED FLOOR STANDARD MOUNTING HEIGHT DETAIL VIETNAMESE MARTYRS 6801 S. 180TH ST. TUKWILLA, WASHINGTON 98188 FIRE ALARM AND VOICE EVACUATION SYSTEM BUILDING PERMIT: D13-175 REVISION: 0 SCOPE OF WORK: Adding (5) five speaker strobes to existing building fire alarm system. Devices are to be added in Classrooms that were previously designated as Offices. Area of work is the outlined area on sheets; FA -1 anc1 EA -2. Revised battery calculations are provided with the submittal documents. El Without Comments O• As Noted in Red Per The Attachedletter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance e s subject rp .,Tors and omissions which not authorize Ioiations of adopted standards and oro 3TCPS The responsibility for the adequacy .of desqr P.15 totally ‘n,:tn Ei e designer, Additions; -zwisions ra rhe drawings after this aacE th cceptance and will require a r•esuhmirca3 .:v.,se,..ctrawings for subsequent approval. Final acceptance i's; subject to field test and Inspection by The Tukwila Fire Prevention Bu eau. ` Dater "11 ' / 7 By: TUKWILA FIRE DEPARTMENT T Y Q #' m ! i 205-575-1407 aT3nd g vt this Fire Permit No. and exact ddrr ;s --for- ut• - down or r 1-� on approval. CONDITION o Qo Q QJCD -0) SEQUENCE OF OPERATIONS 0) FAC P FUNCTIONS m� 0 w� �o J= CD - L Q ��m v tti Q 0 .. O Z ku J Z 7. Z' Z v v QJ ci V JAN Q c7 : /I.:, /:::---,Cr ) /,‘,..._:-..C‘) 00 S v V c) /''i j-1....::...,.--- o Q' 7 v 0) A B C DEFG H STANDBY CONDITION 2 SYSTEM TROUBLE CONDITION 0 0 • 3 SMOKE DETECTOR • • 0 • • 4 PULL STATION 0 0 • • 0 5 WATER FLOW 0 0 • • 0 6 SPRINKLER TAMPER 0 0 THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OF INFINITY FIRE PROTECTION AND ALL RIGHTS ARE EXPRESSLY RESERVED. IT IS SUBMITTED UNDER A TRUST RELATIONSHIP FOR YOUR USE IN CONSIDERING THE PURCHASE OF THE EQUIPMENT DESCRIBED HEREON FROM INFINITY FIRE PROTECTION. THIS DRAWING IS NOT TO BE USED FOR ANY OTHER PURPOSE NOR COPIED IN WHOLE OR PART NOR ITS DESIGN FEATURES USED IN OTHER PRODUCTS WITHOUT OUR WRITTEN CONSENT. IT IS TO BE RETURNED WHEN NO LONGER REQUIRED, OR UPON REQUEST. 0 j •:h. cO rj 0 W 0O I O LIJ 1:)s) 'DOT_ HZ I z. o0: wZw N _ ELI- CT l C..AL NOTES.. SITE MAP THE CONTROL PANEL REQUIRES 120 .VAC, 50/60 HZ, 5 AMP MAX. POWER TO THE CENTRAL PANEL MUST BE A DEDICATED CIRCUIT W/LOCKING BREAKER BY OTHERS. THE 2. ANY EQUIPMENT LOCATION CHANGE FROM THAT SHOWN`Ott DRAWINGS REQUIRES PRIOR APPROVAL. WIRE RESISTANCE FOR DETECTION CIRCUITS • MUST NOT EXCEED 20 OHMS (APPROXIMATELY 3000 FT. OF 18 AWG OR 7700 FT. OF 14 AWG WIRE). 3. DETECTOR, ALARM AND DISCHARGE CIRCUITS ARE SUPERVISED AND MUST BE CONNECTED AS SHOWN. NO PARALLEL CIRCUITS. 4. ALL LOW VOLTAGE SUPERVISORY WIRING FOR EACH ZONE MUST BE SHIELDED FROM, ALL OTHER WIRING. 5. ALL CONTACTS ARE ,RATED AT 1.5 AMP, 120 VAC/2p \VDC. 6. WIRE RANGE FOR TERMINALS IS 14 AWG TO 18 AWG. TWO WIRES ON THE SAME TERMINAL MUST NOT DIFFER BY MOR THAN TWO. GAUGES. .__COMPLIANCE LTH AI. L LOCAL ,WIRING _CODES IS REQUIRED. 7. DO NOT CONNECT DISCHARGE DEVICES TO PANEL. SERVICE TECHNICIAN WILL DO TIE-INS AT FINAL CHECKOUT. 8. 120 VAC SUPPLY AND 24 VDC BATTERY STANDBY MUST BE DISCONNECTED BEFORE PERFORMING ANY TYPE OF SYSTEM MAINTENANCE. ALLOW 30 SECONDS AFTER POWER DISCONNECT BEFORE PERFORMING MAINTENANCE. 9. BATTERY STANDBY TOWER IS PROVIDED FOR THIS SYSTEM. 10. END OF LINE RESISTORS ARE INCLUDED WITH THE PANEL. JEREMY MEDSKER LEVEL 2: 10431$ PAID —. J MAR 21201? 7 UKlT1i14_'i FIRE ec 2ff0 v CC c24 00 az Cr) E cif].<01 FT1 z 0 SUBMITTAL DRAWING t0 z 0 DWG BY: JS ENG BY: JS CHK BY: KR APP BY: JM SCALE: NOT TO SCALE DRAWING NUMBER: 07-100-010 1 OF 5 DATE: 10/1/13 PAGE: CVR THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OF INFINITY FIRE PROTECTION LLC. ALL RIGHTS ARE EXPRESSLY RESERVED. IT IS SUBMITTED UNDER A TRUST RELATIONSHIP FOR YOUR USE IN CONSIDERING THE PURCHASE OF THE EQUIPMENT DESCRIBED HEREON FROM INFINITY FIRE PROTECTION LLC.. THIS --DRAWING IS NOT TO BE USED FOR ANY OTHER PURPOSE NOR COPIED IN WHOLE OR PART NOR ITS DESIGN FEATURES USED IN OTHER PRODUCTS WITHOUT OUR WRITTEN CONSENT. IT IS TO BE RETURNED WHEN NO LONGER REQUIRED, OR UPON REQUEST. LEGEND ITEM PART NUMBER QTY. DESCRIPTION FACP 1 5280XL—EVS 1 FIRE ALARM CONTROL / VOICE EVACUATION CONTROL PANEL AMP 2 EVS-50W _rl 2 VOICE EVACUATION AMPLIFIER PANEL SNAG 3 5495 ' •.' 1 SUPPLEMENTARY NOTIFICATION APPLIANCE CIRCUIT PANEL MM 4 SK—MONITOR-2 5 MONITOR MODULE P 5 SK—PULL—SA 11 MANUAL PULL STATION gil 6 SPSR 28 SPEAKER/STROBE. (WALL MOUNT) X. 7 SR 6 STROBE (WALL MOUNT) ® 8 SPSCR 28 SPEAKER/STROBE (CIELING MOUNT) 0 9 SK—PHOTO 1 . PHOTOELECTRIC SMOKE SENSOR WF 10 PROVIDED BY OTHERS 1 WATER FLOW SWITCH T 11 PROVIDED BY OTHERS 5 TAMPER SWITCH ( 12 SSM24-8 1 8" BELL --I 13 SK—DUCT 4 DUCT DETECTORS ANN 14 5860R 1 REMOTE FIRE ALARM. ANNUNCIATOR BATT 15 12V -18A 1 12VOLT 18 AMP HOUR BATTERIES JEREMY MEDSKER LEVEL 2: 10431$ PAID —. J MAR 21201? 7 UKlT1i14_'i FIRE ec 2ff0 v CC c24 00 az Cr) E cif].<01 FT1 z 0 SUBMITTAL DRAWING t0 z 0 DWG BY: JS ENG BY: JS CHK BY: KR APP BY: JM SCALE: NOT TO SCALE DRAWING NUMBER: 07-100-010 1 OF 5 DATE: 10/1/13 PAGE: CVR 1 1 WIRE GUIDE IDENTIFIER DESCRIPTION WIRE TYPE A SLC CIRCUIT 16/2 FPLP B STROBE CIRCUIT 12/2 FPLP C VOICE NOTIFICATION CIRCUIT 12/2 FPLP SHIELDED. D SBUS CIRCUIT 16/4 FPLP MATCH NORTH FA2 'LINE 0771-1-TFATT TO FA2 11 FIC E -IC G ., 75CD 1W EOL B,C \FL L.. 30CD 1/2W RE\CE B.0 15CD CLASSR_1 30CD 1/2W v 0 110CD 2W TO FA2 LIBARY 1/4W 30CD 1/2W LASSR 7711 CLASSR 30CD 1/2W i C_LLA RATIL\/C STAF-FR v 30CD 1/2W CLASSR j A 2wD <28.2C> EF-ICF - CLASSR -C v 75CD 2W B.0 B,C ST -RAG. 30CD 2W ST RAGE < B,c CLASSR 30CD 30CD 1/2W CLASSR v E 3 75CD <B,c 1W >10_,/ U a U la M TO FA2 SNAC/AMP B,D B,C THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OF INFINITY FIRE PROTECTION LLC. ALL RIGHTS ARE EXPRESSLY RESERVED. IT IS SUBMITTED UNDER A TRUST RELATIONSHIP FOR YOUR USE IN CONSIDERING THE PURCHASE OF THE EQUIPMENT DESCRIBED HEREON FROM INFINITY FIRE PROTECTION LLC. THIS DRAWING IS NOT TO BE USED FOR .ANY OTHER PURPOSE NOR COPIED IN WHOLE OR PART NOR ITS DESIGN FEATURES USED IN OTHER PRODUCTS WITHOUT OUR WRITTEN CONSENT. IT IS TO BE RETURNED WHEN NO LONGER REQUIRED, OR UPON REQUEST. LEGEND ITEM PART NUMBER QTY. DESCRIPTION 1 5280XL-EVS 1 FIRE ALARM CONTROL / VOICE EVACUATION CONTROL PANEL FACP 2 EVS-50W 2 VOICE EVACUATION AMPLIFIER PANEL AMP 3 5495 1 SUPPLEMENTARY NOTIFICATION APPLIANCE CIRCUIT PANEL SNAC 4 SK -MONITOR -2 5 MONITOR MODULE MM 5 SK -PULL -SA 11 MANUAL PULL STATION P 04 6 SPSR 28 SPEAKER/STROBE (WALL MOUNT) )0( 7 SR 6 STROBE (WALL MOUNT) 0 8 SPSCR 28 SPEAKER/STROBE (CIELING MOUNT) 0 9 SK -PHOTO 1 PHOTOELECTRIC SMOKE SENSOR 10 PROVIDED BY OTHERS 1 WATER FLOW SWITCH WF 11 PROVIDED BY OTHERS 5 TAMPER SWITCH T C 12 SSM24-8 1 8" BELL 13 SK -DUCT 4 DUCT DETECTORS _ 14 5860R 1 REMOTE FIRE ALARM ANNUNCIATOR ANN 15 12V -18A 1 12VOLT 18 AMP HOUR BATTERIES BATT � -1 110CD �/ 2W ❑ < B,C > 110CD 2W ST -RAGE RAG B,C 11 EOL 75CD 2W 0 0 \ 110CD 2W TO FA2 1 3 A 110CD 1W B.0 \TRY <ITCHE N i4 i z 0 1 P4 SUBMITTAL DRAWING T) (C7 x co N 0 0 N 0 z 0 0 0 0 CID DWG BY: JS ENG BY: JS CHK BY: JM APP BY: JM SCALE: 1/8"=1' DRAWING NUMBER: 13 -JAS -01 OF DATE: 10/1/13 PAGE: FA1 WIRE GUIDE ,IDENTIFIER DESCRIPTION WIRE TYPE A SLC CIRCUIT 16/2 FPLP B NAC CIRCUIT 12/2 FPLP C VOICE NOTIFICATION CIRCUIT 12/2 FPLP SHIELDED D SBUS CIRCUIT 16/4 FPLP 1 MATCHNORTH FA2 LINE — =O i Ai 110 Or ASSR 1/2W M v CLASSR 30CD M 1/2\N A LASS R B 3 RI\TI EEICL 75CD EOL L_... 19W B,C (7,1ll��o (fPlaowil t FA -12--VP0-D //Li vi K—o 0110CD 2W 75CD �l F\ V 15CD \S S B.0 gC 110CD 2W EEICE CD\ EEICL FERE CL ST_R 2LASSR_❑ v 11OCD 0 2W CLASSR 30CD 1/2W 3000 1/2W o` l . B 30CD 1/2W EOL ❑I�/ " < Bc > CLASSR THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OF INFINITY FIRE PROTECTION LLC. ALL RIGHTS ARE EXPRESSLY RESERVED. IT IS SUBMITTED UNDER A TRUST RELATIONSHIP FOR YOUR USE IN CONSIDERING THE PURCHASE OF THE EQUIPMENT DESCRIBED HEREON FROM INFINITY FIRE PROTECTION LLC. THIS DRAWING IS NOT TO BE USED FOR ANY OTHER PURPOSE NOR COPIED IN WHOLE OR PART NOR ITS DESIGN FEATURES USED IN OTHER PRODUCTS WITHOUT OUR WRITTEN CONSENT. IT IS TO BE RETURNED WHEN NO LONGER REQUIRED, OR UPON REQUEST. LEGEND ITEM PART NUMBER QTY. DESCRIPTION FACP 1 5280XL-EVS 1 FIRE ALARM CONTROL / VOICE EVACUATION CONTROL PANEL AMP 2 EVS-50W 2 VOICE EVACUATION AMPLIFIER PANEL SMAC 3 5495 1 SUPPLEMENTARY NOTIFICATION APPLIANCE CIRCUIT PANEL MM 4 SK—MONITOR-2 5 MONITOR MODULE P 5 SK -PULL -SA 11 MANUAL PULL STATION CA 6 SPSR 28 SPEAKER/STROBE (WALL MOUNT) /�\ 7 SR 6 STROBE (WALL MOUNT) 0 8 SPSCR 28 SPEAKER/STROBE (CIELING MOUNT) 0 9 SK -PHOTO 1 PHOTOELECTRIC SMOKE SENSOR WF 10 PROVIDED BY OTHERS 1 WATER FLOW SWITCH T 11 PROVIDED BY OTHERS 5 TAMPER SWITCH C 12 SSM24-8 1 8" BELL 13 SK -DUCT 4 DUCT DETECTORS -1 1 ANN 14 5860R 1 REMOTE FIRE ALARM ANNUNCIATOR BATT 15 12V -18A 1 12VOLT 18 AMP HOUR BATTERIES 1 v 30C) 1/2W CLASS v 75CD 1/2W CLASSR TO FA1 110CD 2W 110CD 2W ASF- (C<D 75CD EOL 2W roL „l. C E c s5'zo w TO FA1 A.D -t .‹ > 0 11 OCD 2W 1 /2W L-U\G A fad. ti e wetz(< 75CD v 1 E\S SECURITY Kd� fly w 2-15,)22- 1)5,9 II,2 2- 3v-► SACRIST1/ 0 P 5TO FA3 110CD 2W TO FACP ST R < B.0 > B, c ASCD f/ t., 75CD 2W u B,C 0 0 75CD 2W 110CD 2W TO FA3 \ARTHEX < B,C --t 110CD 2W STO FA3 TO FA11 • N Nr. n 4,D0 N) O w co O Cr) CC CO ET_ ><II -z0I -. o E -`z Z oixz o N _ eL x � •4 P1 co z 0 cif) z cfj F.T.1 z 0 SUBMITTAL DRAWING w 0 z 0 DWG BY: JS ENG BY: JS APP BY: JM SCALE: 1/8"=1' CHK BY: KR DRAWING NUMBER: 13 -JAS -01 )) 0 OF DATE: 12/26/07 PAGE: FA2 WIRE GUIDE IDENTIFIER DESCRIPTION WIRE TYPE A SLC CIRCUIT 16/2 FPLP B STROBE CIRCUIT 12/2 FPLP SHIELDED C VOICE NOTIFICATION CIRCUIT 12/2 FPLP D SBUS CIRCUIT 16/4 FPLP 5280XL-EVS TO FA2 --MOM.,... — v `"2W ° B Dcr 115CD /\ 2W J r 000 L L 110CD 2W TO FA1 110CD 2W r AMP n THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OF INFINITY FIRE PROTECTION LLC. ALL RIGHTS ARE EXPRESSLY RESERVED. IT IS SUBMITTED UNDER A TRUST RELATIONSHIP FOR YOUR USE IN CONSIDERING THE PURCHASE OF THE EQUIPMENT DESCRIBED HEREON FROM INFINITY FIRE PROTECTION LLC. THIS DRAWING IS NOT TO BE USED FOR ANY OTHER PURPOSE NOR COPIED IN WHOLE OR PART NOR ITS DESIGN FEATURES USED IN OTHER PRODUCTS WITHOUT OUR WRITTEN CONSENT. IT IS TO BE RETURNED WHEN NO LONGER REQUIRED, OR UPON REQUEST. LEGEND ITEM PART NUMBER QTY. DESCRIPTION FACP 1 5280XL-EVS 1 FIRE ALARM CONTROL / VOICE EVACUATION CONTROL PANEL AMP 2 EVS-50W 2 VOICE EVACUATION AMPLIFIER PANEL SNAC 3 5495 1 SUPPLEMENTARY NOTIFICATION APPLIANCE CIRCUIT PANEL MM 4 SK -MONITOR -2 5 MONITOR MODULE P 5 SK -PULL -SA 11 MANUAL PULL STATION 12/ 6 SPSR 28 SPEAKER/STROBE (WALL MOUNT) /o\ 7 SR 6 STROBE (WALL MOUNT) ® 8 SPSCR 28 SPEAKER/STROBE (CIELING MOUNT) So 9 SK -PHOTO 1 PHOTOELECTRIC SMOKE SENSOR WF 10 PROVIDED BY OTHERS 1 WATER FLOW SWITCH T 11 PROVIDED BY OTHERS 5 TAMPER SWITCH ( 12 SSM24-8 1 8" BELL 13 SK -DUCT 4 DUCT DETECTORS ANN 14 5860R 1 REMOTE FIRE ALARM ANNUNCIATOR BATT 15 12V -18A 1 12VOLT 18 AMP HOUR BATTERIES c0 ') )N oOro0 CO I U. -corny rn� I=-Zo1 Z I O .-11- z Z ww3 CDCYZ N m 0 mft CO 00 C:4 a: w�� cir) z Z m V) ,�OD!Z ?O i)T ro 0 (24 w CD Cf) DWG BY: JS ENG BY: JS CHK BY: KR APP BY: JM SCALE: 1/8"=1' DRAWING NUMBER: 13 -JAS -01 OF DATE: 12/26/07 PAGE: FA3 • • OEMENAL ALARM O RUPERMORY • rmwtrritousul SY11111 POWER [T] CI ) L iLC (7)0 )LSC SOMME ( EH I> 0101 0-10:1_01 1LI - 'L u. *t i pP11ci neo: _ cit -1* P a A e SIM IN ■■■■■■■ IIRllll.11140 • 71 2.3 SUR OUT WATERFLOW (EXISTING) 4.7K EOL TAMPER SWITCHS (EXISTING) f 4.71( EOL • • 75CD rph 1W n 30CD 1/2W A 1/2W 1/2W 110CD 2W W 30CD 1/2W 30CD 1/2W 30CD I--(( 1/2w 15CD 1 /4W 75CD 2W 30CD 2W 110CD 2W 30CD 1/2W 30CD 1/2W 15CD 30CD 1/2W 75CD 1W STORAGE ROOM AMPLIFIER BATTERY CALCULATIONS A 0 • 4.71< EOL COMPONENTS QTY. STANDBY CURRENT ALARM 1 CURRENT ALARM CURRENT EVS-50W 1 0.085A TOTAL WATTS 0.525A TOTAL WATTS 46 OA 0.085A 2.070A TOTAL 0.085A X STANDBY TIME 2.595A TOTAL STANDBY CURRENT DRAW = 2.04 AH 0.085 AMPS X STANDBY TIME X ALARM TIME 24 HOURS STANDBY AMP HOUR TOTAL = 0.1677 AH 2.04 AH TOTAL ALARM CURRENT DRAW = ALARM AMP -HOURS REQUIRED = 2.595 AMPS X ALARM TIME 2.2077 AH 0.083 HOURS ALARM AMP HOUR TOTAL = MINIMUM BATTERY SIZE NEEDED: 0.2154 AH STANDBY AMP -HOURS REQUIRED = MANUAL PULL STATION 2.04 AH ALARM AMP -HOURS REQUIRED = SPSR 0.2154 AH TOTAL AH REQUIRED = A 2.2554 AH X DE -RATING FACTOR 6 1.20 (20%) MINIMUM BATTERY SIZE NEEDED: 8 2.7065 AH . . r.- .-..-.-, r-... . AI .-. r . .ik ii i Tr r-, el f- AI A x111 TI11r : U. 11 OCD 2W 75CD 2W 11 OCD 2W 110CD�-( 1W IM 75CD 2W 75CD 2W 110CD 2W 11 OCD 2W 110CD 2W 110CD 2W 4.71( EOL 400 OW ❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑ V❑DEL 5495 O UTDUT 1 O UT AUT 2 O UTDUT .3 O UTPUT 1 .r_ 15CD 75CD 2W 75CD 2W 75CD 2W 110CD 2W 75CD M 15CD 30CD 2W 30CD 1W 75CD 2W 110CD 4.7K EOL 110CD 2W 75CD 2W 75CD 1/2W 110CD 2W 30CD 1/2W 30CD 1/2W 110CD 2W 30CD 1/2W A 30CD 1/2W 4.7K EOL 110CD 2W 110CD 2W 115CD 2W 110CD 2W lM 110CD 2W 4.7K EOL 110CD 2W 75CD 110CD 2W 110CD 2W 75CD 1/2W 30CD 1/2W 110CD 2W 30CD 1/2W 30CD 1/2W 30CD 1 /2W 75CD 2W 4.7K EOL RISER ROOM AMPLIFIER BATTERY CALCULATIONS COMPONENTS QTY. STANDBY CURRENT ALARM 1 CURRENT EVS-50W 1 0.085A 0.525A TOTAL WATTS 33.25 OA 1.496A TOTAL 0.085A 2.021A TOTAL STANDBY CURRENT DRAW = 0.085 AMPS X STANDBY TIME 24 HOURS STANDBY AMP HOUR TOTAL = 2.04 AH TOTAL ALARM CURRENT DRAW = 2.021 AMPS X ALARM TIME 0.083 HOURS ALARM AMP HOUR TOTAL = 0.1677 AH STANDBY AMP -HOURS REQUIRED = 2.04 AH ALARM AMP -HOURS REQUIRED = 0.1677 AH TOTAL AH REQUIRED = 2.2077 AH X DE -RATING FACTOR _ 1.20 (20%) MINIMUM BATTERY SIZE NEEDED: 2.6492 AH .. w r' 1 11K 11 1Tf-r r'1I- A I A ill A TI1 4 1 IVV It: U.UtS.J L UHLJ IVIIIVV IGJ VE /1LfifClVl THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OF INFINITY. FIRE PROTECTION LLC. ALL RIGHTS ARE EXPRESSLY RESERVED. IT IS SUBMITTED UNDER A TRUST RELATIONSHIP FOR YOUR USE IN CONSIDERING THE PURCHASE OF THE EQUIPMENT DESCRIBED HEREON FROM INFINITY FIRE PROTECTION LLC. THIS DRAWING IS NOT TO BE USED FOR ANY OTHER PURPOSE NOR COPIED IN WHOLE OR PART NOR ITS DESIGN FEATURES USED IN OTHER PRODUCTS WITHOUT OUR WRITTEN CONSENT. IT IS TO BE RETURNED WHEN NO LONGER REQUIRED, OR UPON REQUEST. QTY. QTY. LEGEND ITEM PART NUMBER QTY. DESCRIPTION SPSR 0.275A 0.4A ALARM ' RELAY 1 FACP 1 5280XL-EVS 1 FIRE ALARM CONTROL / VOICE EVACUATION CONTROL PANEL AMP 2 EVS-50W 2 VOICE EVACUATION AMPLIFIER PANEL SNAC 3 5495 1 SUPPLEMENTARY NOTIFICATION APPLIANCE CIRCUIT PANEL MM 4 SK -MONITOR -2 5 MONITOR MODULE 0.004125A n 5 SK -PULL -SA 11 MANUAL PULL STATION EK 6 SPSR 28 SPEAKER/STROBE (WALL MOUNT) A 7 SR 6 STROBE (WALL MOUNT) ® 8 SPSCR 28 SPEAKER/STROBE (CIELING MOUNT) SO 9 SK -PHOTO 1 PHOTOELECTRIC SMOKE SENSOR WF 10 PROVIDED BY OTHERS 1 WATER FLOW SWITCH T 11 PROVIDED BY OTHERS 5 TAMPER SWITCH ( 12 SSM24-8 1 8" BELL 13 SK -DUCT 4 DUCT DETECTORS 1 ANN 14 5860R 1 REMOTE FIRE ALARM ANNUNCIATOR BATT 15 12V -18A 1 12VOLT 18 AMP HOUR BATTERIES 0 FACP BATTERY CALCULATIONS COMPONENTS QTY. QTY. STANDBY CURRENT ALARM CURRENT 5820XL-EVS FACP 1 CIRCUIT 1 SPSR 0.275A 0.4A ALARM ' RELAY 1 OA " OA TROUBLE RELAY 1 .632A OA OA 2 30 SUPERVISORY CURRENT ALARM CURRENT PULL STATIONS 11 0.000375A 0.000375A 0.004125A 0.004125A DUCT DETECTOR 4 0.00027A 0.00027A 0.00108A 0.00108A ANNUCIATOR 1 0.02A 0.025A 0.02A 0.025A EVS50 VOICE AMP 2 0.01A 0.01A 0.02A 0.02A SMOKE DETECTOR 1 0.0003A 0.0003A 0.0003A 0.0003A MONITOR MODULE 5 0.00075A 0.00075A 0.000375A 0.000375A VOICE MODULE 1 0.07A 0.1A 0.07A 0.1A ZONE 1 INPUT 1 0.015A 0.015A 0.015A 0.015A ZONE 2 INPUT 1 0.015A 0.15A 0.015A 0.15A STANDBY CURRENT ALARM CURRENT NAC CKT 1 0 1.856 OA 1.856A NAC CKT 2 0 1.888 OA 1.888A NAC CKT 3 0 0.0 OA 0.000A 1-0TAL 0.4209A 4.4599A TOTAL STANDBY CURRENT DRAW = 0.4209 AMPS X STANDBY TIME 24 HOURS STANDBY AMP HOUR TOTAL = 10.102 AH TOTAL ALARM CURRENT DRAW = 4.4599 AMPS X ALARM TIME 0.083 HOURS ALARM AMP HOUR TOTAL = 0.3702 AH STANDBY AMP -HOURS REQUIRED = 10.102 AH ALARM AMP -HOURS REQUIRED = 0.3702 AH TOTAL AH REQUIRED = 10.4722 AH X DE -RATING FACTOR 1.20 (20%) MINIMUM BATTERY SIZE NEEDED: 12.5667 AH 2 SNAC BATTERY CALCULATIONS `CIRCUIT DEVICE QTY. CANDELAS CURRENT DRAW TOTAL CURRENT CIRCUIT C TOTAL CIRCUIT 1 SPSR 1 110 .202A .202A SPSCR 4 75 .158A .632A SPSCR 2 30 •.094A .188A SR 1 75 .158A .158A SR 2 15 .066A .132A SSM24-8 1 .331A .331A 1.64A CIRCUIT 2 SPSCR 3 110 .202A .606A SPSCR 1 -75 .158A .158A SPSR 1 75 .158A .158A SPSR 4 30 .094A .376A 1.3A CIRCUIT 3 SPSR 1 115 .210A .210A SPSR 4 110 .202A .808A 1.02A CIRCUIT 4 SPSCR 4 110 .202A .808A SPSCR 1 75 .158A .158A SPSR 2 75 ..158A .316A SPSR 4 30 .094A .376A 1.66A TOTAL 5.63A TOTAL STANDBY CURRENT DRAW = 0.075 AMPS X STANDBY TIME 24 HOURS STANDBY AMP HOUR TOTAL = 1.8 AH TOTAL ALARM CURRENT DRAW = 5.58 AMPS X ALARM TIME 0.083 HOURS ALARM AMP HOUR TOTAL = 0.485 AH STANDBY AMP -HOURS REQUIRED = 1.8 AMPS ALARM AMP -HOURS REQUIRED = 0.485 AH TOTAL AH REQUIRED = 2.284 AH X DE -RATING FACTOR 1.20 (20%) MINIMUM BATTERY SIZE NEEDED: 2.74 AH . -- .-. ... r_ .. . .... . -.. . - IVU I : U.UZ5.7 tUUHLJ MIIV. c0 j . N GV) DO W°O I U (naaj w cY)00E >QII 1-- ZI - I 0 I r Z w LIJ oN.� r a who F7-1 €-1z cfrj E-4 SUBMITTAL DRAWING 0 z 0 UD E:11 E';"( w � � g) cA3 DWG BY: JS ENG BY: JS CHK BY: KR APP BY: JM SCALE: NOT TO SCALE DRAWING NUMBER: 1 3 -JAS -01 OF DATE: PAGE: