Fire Sprinklor SpcclQlista
JOB NAME: CARLYLE INC.
ADRESS: 6801 SOUTH 1501 ST. TUTKWLLA, WA 9818
'ACCEPTED
Existing offices were refigured to turn two offices
Add new brass'" 155 deg. Globe pendant sprinkl
office.
Tee off exiting 1" drop in adjacent office.
11021 Cramer Rd. KPN •
Without Comments
As N ted In Red
401
WOW PAYE' Letter
i nese plans have been reviewed by The Tukwila Fire
n 'on Bureau for conformance with current city
standar s. Acceptance is subject to errors and
omissions which do of authorize violations of adopted
n. • rain noes. The responsibility for the
ign rests totally with the designer.
ons1or revisions to these drawings atter
acceptance and wilt require a
drawings for subsequent approv
stance
adequ
Additio
this da
resub
Final a. _''r; "*�* �. ubject to field test and inspection
The Tu. - : P : vention Bu
.Date:
/I �i ,!v By: 900
j
I UKWILA FIRL Utt'r,rc �w::ir{
Please call: 575-4407
and give this job
No. o 5 396
and exact address for shut•
or restoration aporowat
V+
Gig Harbor, WA 98329 • Office (263) 857-2056 • Fax (253) 857-2312 • Local 699 Contractor
Security Solutions
Stanley Convergent Security Solutions, Inc.
2700 Richards Rd. Suite 202
Bellevue, WA 98005
November 14, 2011
City of Tukwila
Al Metzler
444 Andover Park E
Tukwila, WA 98188
Fire permit: Carlisle Interconnect Technologies
Location: 6801 S 180th Street Tukwila, WA
Scope of work:
This location has up graded the HVAC unit to a larger unit. It went from a 2 ton to 5 ton
unit. The old unit had a duct detector that was connected to the existing fire panel on a
supervisory point. When the old unit was removed and the new unit installed we need to
reconnect the wires to the new duck detector for monitoring. We need to reestablish the
connection to the existing fire panel. After the connection has been made and tested we
will call for final inspection and sign off.
. Howard Richardson
425-957-7025
Fax: 425-746-0084
hichardson@stanleyworks.com
TUKWILA FIRE DEPARTMENT
Please call 206-575-4407 and
give this Fire Pe;'mit No.
and exact address forshut-
down
ut-
down or restoration approval.
No print is needed for this scope of work because the only change is a HVAC unit up
grade.
Please call Howard Richardson for any additional i
Howard Ri
Stanley Security
425-957-7025
howard.richardson@sbdinc.com
NOTICE
A completed, signed, Tukwila
Fire Department Pre-test
Certificate must be presented
to the Inspector prior to
commencement of Acceptance
Testing of any Fire Alarm
and Detection Systems.
Failure of test will result
in a Re -inspection Fee and
termination of the testing,
TED
, f wit': '' t Comments
O n Rad
p Pc, ; ne Attached Letter
---z. plans have beer- reviewed hal The Tukwila Fire
r cion bureau for amforrna"'ce with current City
arils. ACCCDtECE is sub_e i to r.rrors and
--erns whirr, o+:. ,;roarions of adopted
aarcis and The ; esoorsiniiity for the
J.:.+acy of o° -.,:,r •(e.7•(est.7 totaiiv -wor; the ,;:signer.
'CTs, deieti t V,)'] -11:-.;e drawings afte
, f require a
of revised drawings for suosequent approval.
=final acceptarice !s suclect to field test and inspection by
The Tukwila Fire Prevention Bureau.
Date: //-15-- / ( By:
sl
t7
S
0
N
0
O -t
CV
O
O
o
O
V/
N_
0
u).
fl.
O
O
N
O
V/
N_
co
0)
CV
0
0
O
N
O
V/
N_
4t
CO
0
O.
00
t!)
tV
0
0
O
O
VJ
N_
O
O
O
VJ
N_
O
O
O
0.
E
c
1
1-
co
co
0
ti
O.
O
5495 Pwr Module
O
O
0
O
5495 Circuit 1
O
O
O
O.
5495 Circuit 2
O
O
O.
O.
5495 Circuit 3
T
O
0
0
O
.1:igli15495 Circuit 4
0
0
O
54
to:
1:
aec
0)
uto
G
.0
E
0
:SSS
i3Gt
g
Configure Circuits
i
IN' ,Ii(';\:1.111'
Circuit Configuration
Project Information
Project Name: Vietnamese Martyers Church
Prepared By: Matt Thawsh
Project ID: 0
Date: 3/1/2017
DevjQe
System Sensor S/SC Strobe (110cd)
................................
netts 5495
Circuit Corm
............................
:,:!%000.:POKR404igurterzt t?raw Totat '_:
Standby ...Malty, .. :Standl y Alarm s;
0,000:: 0 000 (1202 ..:
0.202
5
System Sensor S/SC Strobe (75cd)
0 000<
€58
0790
2
8
System Sensor S/SC Strobe (30cd)
System Sensor S/SC Strobe (15cd)
1.091 t 000 !(.
0,066
0.1
0 528
0000 tf <,
0
3
Name: 5495 Citcutt.2€
System Sensor S/SC Strobe (110cd)
Totals
Max Circuit Current
1708
Ctlrretit i kaw Each tirr It Draw i QtaI
Standby Alarm . $tarydby Alarm,,:;;:;;
0 000
2
System Sensor S/SC Strobe (75cd)
0000.
0.1;58
5
4
System Sensor S/SC Strobe (30cd)
.::.::.;0.00 0'::.:.::.;
.........................
375:::>`
..............
Unused
0000!
..........................
0:000
......................
06....
aggt00.Q1jR
......................
pt
Name,.]
5Circuit 3
........................ .
Panel ID
ax Circuit
Totals
0.000
298
Curr rit Draw Each, Current trawTotat <
Standby Alarm Standby Alarm
System Sensor S/SC Strobe (115cd)
0.210
NiXfating
4
System Sensor S/SC Strobe (110cd)
0:000:
..............
epi
O
Unused
0,01w..
Unused
0000
.........................
1 ;11000
6 .300
0 000
0000
Totals
0.000
1.018
...................
Qtv
Dev4ce< :
anent C
Indby
aw Each t[rrent Draw Total; t
Afarm, Starry Alarm :'
4
System Sensor S/SC Strobe (110cd)
001N:N
808
3
System Sensor S/SC Strobe (75cd)
ditrObigi
0474
4
System Sensor S/SC Strobe (30cd)
I Ori:
0 000
Unused
O ti00
X000..
0.000
0.000 >;
0 000
000 <!
Totals
0.000
1.658
5495
............................. .
...............................
................................
rctht CLUTeni. 3 Amis
ae
Gtrtfe t f raw: actr Got ant t:3 4. Tngli .>>
Standby Arm ... .Stat d y Alarm <;
Unused
El 00Q
..........................
t1i300:>
.....................
Unused
..........................
Unused
Di
Unused
>0 000
(3000 ;
0400
Totals
0.000 :..
•:: 0'000
DRAWING DIRECTORY
(SHEET #:
SHEET TITLE:
FIRE ALARM CONTROL PANEL
ITEM
.CVR
COVER SHEET, BILL OF MATERIALS AND GENERAL INFORMATION
FA1
SOUTH FLOOR PLAN
FA2
NORTH FLOOR PLAN
FA3
SANCTUARY FLOOR PLAN
FA4
ELECTRICAL SCHEMATIC & BATTERY CALCULATIONS
MANUAL PULL STATION
CONSULTANTS
PROJECT NAME:
VIETNAMESE MARTYRS
FIRE ALARM AND VOICE EVACUATION SYSTEM
6801 S 180TH ST.
TUKWILLA, WASHINGTON 98188
FIRE ALARM SUPPLIER:
INFINITY FIRE PROTECTION
17701 108TH AVE SE #426
RENTON, WASHINGTON 98055
PHONE: (206) 381-3090
WWW.INFINITY-FIRE.COM
REFERENCES:
NFPA 70 NATIONAL ELECTRICAL CODE
NFPA 72 NATIONAL FIRE CODE
UL -864 AND OTHER APPLICABLE STANDARDS
COMPLETE FIRE PROTECTION SYSTEM, UL LISTED
CONFORM TO REQUIREMENTS OF NFPA APPLICABLE SECTIONS
THE AMERICAN DISABILITIES ACT (ADA)
ABBREVIATIONS
0 MOUNT NOTIFICATION DEVICES 80" ABOVE FLOOR
OR 6" BELOW CEILING, WHICHEVER IS LOWER,
PER ADA REQUIREMENTS.
"T". BAR CEILING
-36"
MAX.
DIFFUSER
DOOR
OUTSIDE
OF
ROOM
FIRE
EVAC
PANEL
A
f
NOT LESS THAN 3 -
NOT MORE THAN 4'-6"
7/
72"
ANN
BOTTOM OF LENS
NOT LESS THAN
80" AND NO
GREATER THAN 96"
(7.5.4)
48"-60"
FINISHED FLOOR
STANDARD MOUNTING HEIGHT DETAIL
VIETNAMESE MARTYRS
6801 S. 180TH ST.
TUKWILLA, WASHINGTON 98188
FIRE ALARM AND VOICE EVACUATION SYSTEM
BUILDING PERMIT: D13-175
REVISION: 0
SCOPE OF WORK:
Adding (5) five speaker strobes to existing building fire alarm system. Devices are to be added in
Classrooms that were previously designated as Offices. Area of work is the outlined area on sheets; FA -1
anc1 EA -2. Revised battery calculations are provided with the submittal documents.
El Without Comments
O• As Noted in Red
Per The Attachedletter
These plans have been reviewed by The Tukwila Fire
Prevention Bureau for conformance with current City
standards. Acceptance e s subject rp .,Tors and
omissions which not authorize Ioiations of adopted
standards and oro 3TCPS The responsibility for the
adequacy .of desqr P.15 totally ‘n,:tn Ei e designer,
Additions; -zwisions ra rhe drawings after
this aacE th cceptance and will require a
r•esuhmirca3 .:v.,se,..ctrawings for subsequent approval.
Final acceptance i's; subject to field test and Inspection by
The Tukwila Fire Prevention Bu eau. `
Dater "11 ' / 7 By:
TUKWILA FIRE DEPARTMENT
T
Y Q #' m ! i 205-575-1407 aT3nd
g vt this Fire Permit No.
and exact ddrr ;s --for- ut•
-
down or r 1-� on approval.
CONDITION
o
Qo Q
QJCD
-0)
SEQUENCE OF OPERATIONS
0)
FAC P
FUNCTIONS
m�
0
w�
�o J=
CD
- L
Q
��m v
tti Q 0 ..
O
Z
ku J Z
7.
Z' Z
v
v QJ
ci V JAN Q c7
: /I.:, /:::---,Cr ) /,‘,..._:-..C‘)
00
S v V c) /''i j-1....::...,.--- o
Q' 7 v 0)
A B C DEFG H
STANDBY CONDITION
2
SYSTEM TROUBLE CONDITION
0
0
•
3
SMOKE DETECTOR
•
•
0
•
•
4
PULL STATION
0
0
•
•
0
5
WATER FLOW
0
0
•
•
0
6
SPRINKLER TAMPER
0
0
THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OF INFINITY FIRE PROTECTION
AND ALL RIGHTS ARE EXPRESSLY RESERVED. IT IS SUBMITTED UNDER A TRUST RELATIONSHIP
FOR YOUR USE IN CONSIDERING THE PURCHASE OF THE EQUIPMENT DESCRIBED HEREON FROM
INFINITY FIRE PROTECTION. THIS DRAWING IS NOT TO BE USED FOR ANY OTHER PURPOSE NOR
COPIED IN WHOLE OR PART NOR ITS DESIGN FEATURES USED IN OTHER PRODUCTS WITHOUT OUR
WRITTEN CONSENT. IT IS TO BE RETURNED WHEN NO LONGER REQUIRED, OR UPON REQUEST.
0
j
•:h.
cO rj 0
W 0O I O
LIJ 1:)s) 'DOT_
HZ I z.
o0:
wZw
N _
ELI- CT
l C..AL NOTES..
SITE MAP
THE CONTROL PANEL REQUIRES 120 .VAC, 50/60 HZ, 5 AMP MAX. POWER TO THE CENTRAL PANEL
MUST BE A DEDICATED CIRCUIT W/LOCKING BREAKER BY OTHERS.
THE
2. ANY EQUIPMENT LOCATION CHANGE FROM THAT SHOWN`Ott DRAWINGS REQUIRES PRIOR
APPROVAL. WIRE RESISTANCE FOR DETECTION CIRCUITS • MUST NOT EXCEED 20 OHMS
(APPROXIMATELY 3000 FT. OF 18 AWG OR 7700 FT. OF 14 AWG WIRE).
3. DETECTOR, ALARM AND DISCHARGE CIRCUITS ARE SUPERVISED AND MUST BE CONNECTED AS SHOWN.
NO PARALLEL CIRCUITS.
4. ALL LOW VOLTAGE SUPERVISORY WIRING FOR EACH ZONE MUST BE SHIELDED FROM,
ALL OTHER WIRING.
5. ALL CONTACTS ARE ,RATED AT 1.5 AMP, 120 VAC/2p \VDC.
6. WIRE RANGE FOR TERMINALS IS 14 AWG TO 18 AWG. TWO WIRES ON THE SAME TERMINAL MUST
NOT DIFFER BY MOR THAN TWO. GAUGES. .__COMPLIANCE LTH AI. L LOCAL ,WIRING _CODES IS REQUIRED.
7. DO NOT CONNECT DISCHARGE DEVICES TO PANEL. SERVICE TECHNICIAN WILL DO TIE-INS AT
FINAL CHECKOUT.
8. 120 VAC SUPPLY AND 24 VDC BATTERY STANDBY MUST BE DISCONNECTED BEFORE PERFORMING
ANY TYPE OF SYSTEM MAINTENANCE. ALLOW 30 SECONDS AFTER POWER DISCONNECT BEFORE
PERFORMING MAINTENANCE.
9. BATTERY STANDBY TOWER IS PROVIDED FOR THIS SYSTEM.
10. END OF LINE RESISTORS ARE INCLUDED WITH THE PANEL.
FACP
FIRE ALARM CONTROL PANEL
ITEM
PART NUMBER
AMP
VOICE AMPLIFIER PANEL
SNAG
SUPPLEMENTAL NOTIFICATION PANEL
FACP
P
MANUAL PULL STATION
1
FIRE ALARM CONTROL / VOICE EVACUATION CONTROL PANEL
H/S
HORN STROBE
2
EVS-50W _rl
ANN
REMOTE FIRE ALARM ANNUCIATOR
SNAG
MM
MONITOR MODULE
1
SUPPLEMENTARY NOTIFICATION APPLIANCE CIRCUIT PANEL
RM
RELAY MODULE
SK—MONITOR-2
5
RM
RELAY MODULE
5
SK—PULL—SA
SCM
SUPERVISED CONTROL MODULE
gil
6
SD
SMOKE DETECTOR
SPEAKER/STROBE. (WALL MOUNT)
X.
WP
WEATHER PROOF
6
t
®
I
0 MOUNT NOTIFICATION DEVICES 80" ABOVE FLOOR
OR 6" BELOW CEILING, WHICHEVER IS LOWER,
PER ADA REQUIREMENTS.
"T". BAR CEILING
-36"
MAX.
DIFFUSER
DOOR
OUTSIDE
OF
ROOM
FIRE
EVAC
PANEL
A
f
NOT LESS THAN 3 -
NOT MORE THAN 4'-6"
7/
72"
ANN
BOTTOM OF LENS
NOT LESS THAN
80" AND NO
GREATER THAN 96"
(7.5.4)
48"-60"
FINISHED FLOOR
STANDARD MOUNTING HEIGHT DETAIL
VIETNAMESE MARTYRS
6801 S. 180TH ST.
TUKWILLA, WASHINGTON 98188
FIRE ALARM AND VOICE EVACUATION SYSTEM
BUILDING PERMIT: D13-175
REVISION: 0
SCOPE OF WORK:
Adding (5) five speaker strobes to existing building fire alarm system. Devices are to be added in
Classrooms that were previously designated as Offices. Area of work is the outlined area on sheets; FA -1
anc1 EA -2. Revised battery calculations are provided with the submittal documents.
El Without Comments
O• As Noted in Red
Per The Attachedletter
These plans have been reviewed by The Tukwila Fire
Prevention Bureau for conformance with current City
standards. Acceptance e s subject rp .,Tors and
omissions which not authorize Ioiations of adopted
standards and oro 3TCPS The responsibility for the
adequacy .of desqr P.15 totally ‘n,:tn Ei e designer,
Additions; -zwisions ra rhe drawings after
this aacE th cceptance and will require a
r•esuhmirca3 .:v.,se,..ctrawings for subsequent approval.
Final acceptance i's; subject to field test and Inspection by
The Tukwila Fire Prevention Bu eau. `
Dater "11 ' / 7 By:
TUKWILA FIRE DEPARTMENT
T
Y Q #' m ! i 205-575-1407 aT3nd
g vt this Fire Permit No.
and exact ddrr ;s --for- ut•
-
down or r 1-� on approval.
CONDITION
o
Qo Q
QJCD
-0)
SEQUENCE OF OPERATIONS
0)
FAC P
FUNCTIONS
m�
0
w�
�o J=
CD
- L
Q
��m v
tti Q 0 ..
O
Z
ku J Z
7.
Z' Z
v
v QJ
ci V JAN Q c7
: /I.:, /:::---,Cr ) /,‘,..._:-..C‘)
00
S v V c) /''i j-1....::...,.--- o
Q' 7 v 0)
A B C DEFG H
STANDBY CONDITION
2
SYSTEM TROUBLE CONDITION
0
0
•
3
SMOKE DETECTOR
•
•
0
•
•
4
PULL STATION
0
0
•
•
0
5
WATER FLOW
0
0
•
•
0
6
SPRINKLER TAMPER
0
0
THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OF INFINITY FIRE PROTECTION
AND ALL RIGHTS ARE EXPRESSLY RESERVED. IT IS SUBMITTED UNDER A TRUST RELATIONSHIP
FOR YOUR USE IN CONSIDERING THE PURCHASE OF THE EQUIPMENT DESCRIBED HEREON FROM
INFINITY FIRE PROTECTION. THIS DRAWING IS NOT TO BE USED FOR ANY OTHER PURPOSE NOR
COPIED IN WHOLE OR PART NOR ITS DESIGN FEATURES USED IN OTHER PRODUCTS WITHOUT OUR
WRITTEN CONSENT. IT IS TO BE RETURNED WHEN NO LONGER REQUIRED, OR UPON REQUEST.
0
j
•:h.
cO rj 0
W 0O I O
LIJ 1:)s) 'DOT_
HZ I z.
o0:
wZw
N _
ELI- CT
l C..AL NOTES..
SITE MAP
THE CONTROL PANEL REQUIRES 120 .VAC, 50/60 HZ, 5 AMP MAX. POWER TO THE CENTRAL PANEL
MUST BE A DEDICATED CIRCUIT W/LOCKING BREAKER BY OTHERS.
THE
2. ANY EQUIPMENT LOCATION CHANGE FROM THAT SHOWN`Ott DRAWINGS REQUIRES PRIOR
APPROVAL. WIRE RESISTANCE FOR DETECTION CIRCUITS • MUST NOT EXCEED 20 OHMS
(APPROXIMATELY 3000 FT. OF 18 AWG OR 7700 FT. OF 14 AWG WIRE).
3. DETECTOR, ALARM AND DISCHARGE CIRCUITS ARE SUPERVISED AND MUST BE CONNECTED AS SHOWN.
NO PARALLEL CIRCUITS.
4. ALL LOW VOLTAGE SUPERVISORY WIRING FOR EACH ZONE MUST BE SHIELDED FROM,
ALL OTHER WIRING.
5. ALL CONTACTS ARE ,RATED AT 1.5 AMP, 120 VAC/2p \VDC.
6. WIRE RANGE FOR TERMINALS IS 14 AWG TO 18 AWG. TWO WIRES ON THE SAME TERMINAL MUST
NOT DIFFER BY MOR THAN TWO. GAUGES. .__COMPLIANCE LTH AI. L LOCAL ,WIRING _CODES IS REQUIRED.
7. DO NOT CONNECT DISCHARGE DEVICES TO PANEL. SERVICE TECHNICIAN WILL DO TIE-INS AT
FINAL CHECKOUT.
8. 120 VAC SUPPLY AND 24 VDC BATTERY STANDBY MUST BE DISCONNECTED BEFORE PERFORMING
ANY TYPE OF SYSTEM MAINTENANCE. ALLOW 30 SECONDS AFTER POWER DISCONNECT BEFORE
PERFORMING MAINTENANCE.
9. BATTERY STANDBY TOWER IS PROVIDED FOR THIS SYSTEM.
10. END OF LINE RESISTORS ARE INCLUDED WITH THE PANEL.
JEREMY MEDSKER
LEVEL 2: 10431$
PAID —.
J MAR 21201?
7 UKlT1i14_'i FIRE
ec 2ff0
v CC
c24 00
az
Cr)
E
cif].<01
FT1
z
0
SUBMITTAL DRAWING
t0
z
0
DWG BY: JS
ENG BY: JS
CHK BY: KR
APP BY: JM
SCALE: NOT TO SCALE
DRAWING NUMBER:
07-100-010
1 OF
5
DATE:
10/1/13
PAGE:
CVR
THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OF INFINITY FIRE PROTECTION LLC.
ALL RIGHTS ARE EXPRESSLY RESERVED. IT IS SUBMITTED UNDER A TRUST RELATIONSHIP FOR YOUR
USE IN CONSIDERING THE PURCHASE OF THE EQUIPMENT DESCRIBED HEREON FROM INFINITY FIRE
PROTECTION LLC.. THIS --DRAWING IS NOT TO BE USED FOR ANY OTHER PURPOSE NOR COPIED IN
WHOLE OR PART NOR ITS DESIGN FEATURES USED IN OTHER PRODUCTS WITHOUT OUR WRITTEN CONSENT.
IT IS TO BE RETURNED WHEN NO LONGER REQUIRED, OR UPON REQUEST.
LEGEND
ITEM
PART NUMBER
QTY.
DESCRIPTION
FACP
1
5280XL—EVS
1
FIRE ALARM CONTROL / VOICE EVACUATION CONTROL PANEL
AMP
2
EVS-50W _rl
2
VOICE EVACUATION AMPLIFIER PANEL
SNAG
3
5495 ' •.'
1
SUPPLEMENTARY NOTIFICATION APPLIANCE CIRCUIT PANEL
MM
4
SK—MONITOR-2
5
MONITOR MODULE
P
5
SK—PULL—SA
11
MANUAL PULL STATION
gil
6
SPSR
28
SPEAKER/STROBE. (WALL MOUNT)
X.
7
SR
6
STROBE (WALL MOUNT)
®
8
SPSCR
28
SPEAKER/STROBE (CIELING MOUNT)
0
9
SK—PHOTO
1 .
PHOTOELECTRIC SMOKE SENSOR
WF
10
PROVIDED BY OTHERS
1
WATER FLOW SWITCH
T
11
PROVIDED BY OTHERS
5
TAMPER SWITCH
(
12
SSM24-8
1
8" BELL
--I
13
SK—DUCT
4
DUCT DETECTORS
ANN
14
5860R
1
REMOTE FIRE ALARM. ANNUNCIATOR
BATT
15
12V -18A
1
12VOLT 18 AMP HOUR BATTERIES
JEREMY MEDSKER
LEVEL 2: 10431$
PAID —.
J MAR 21201?
7 UKlT1i14_'i FIRE
ec 2ff0
v CC
c24 00
az
Cr)
E
cif].<01
FT1
z
0
SUBMITTAL DRAWING
t0
z
0
DWG BY: JS
ENG BY: JS
CHK BY: KR
APP BY: JM
SCALE: NOT TO SCALE
DRAWING NUMBER:
07-100-010
1 OF
5
DATE:
10/1/13
PAGE:
CVR
1
1
WIRE GUIDE
IDENTIFIER
DESCRIPTION
WIRE TYPE
A
SLC CIRCUIT
16/2 FPLP
B
STROBE CIRCUIT
12/2 FPLP
C
VOICE NOTIFICATION CIRCUIT
12/2 FPLP SHIELDED.
D
SBUS CIRCUIT
16/4 FPLP
MATCH NORTH FA2
'LINE 0771-1-TFATT
TO FA2
11
FIC
E -IC
G
.,
75CD
1W
EOL
B,C
\FL
L..
30CD
1/2W
RE\CE
B.0
15CD
CLASSR_1
30CD
1/2W
v
0
110CD
2W
TO FA2
LIBARY
1/4W
30CD
1/2W
LASSR
7711
CLASSR
30CD
1/2W
i
C_LLA
RATIL\/C
STAF-FR
v
30CD
1/2W
CLASSR
j
A 2wD
<28.2C>
EF-ICF
-
CLASSR
-C
v
75CD
2W
B.0 B,C
ST -RAG.
30CD
2W
ST RAGE
< B,c
CLASSR
30CD
30CD
1/2W
CLASSR
v
E
3
75CD
<B,c
1W
>10_,/
U
a
U
la
M
TO FA2
SNAC/AMP
B,D
B,C
THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OF INFINITY FIRE PROTECTION LLC.
ALL RIGHTS ARE EXPRESSLY RESERVED. IT IS SUBMITTED UNDER A TRUST RELATIONSHIP FOR YOUR
USE IN CONSIDERING THE PURCHASE OF THE EQUIPMENT DESCRIBED HEREON FROM INFINITY FIRE
PROTECTION LLC. THIS DRAWING IS NOT TO BE USED FOR .ANY OTHER PURPOSE NOR COPIED IN
WHOLE OR PART NOR ITS DESIGN FEATURES USED IN OTHER PRODUCTS WITHOUT OUR WRITTEN CONSENT.
IT IS TO BE RETURNED WHEN NO LONGER REQUIRED, OR UPON REQUEST.
LEGEND
ITEM
PART NUMBER
QTY.
DESCRIPTION
1
5280XL-EVS
1
FIRE ALARM CONTROL / VOICE EVACUATION CONTROL PANEL
FACP
2
EVS-50W
2
VOICE EVACUATION AMPLIFIER PANEL
AMP
3
5495
1
SUPPLEMENTARY NOTIFICATION APPLIANCE CIRCUIT PANEL
SNAC
4
SK -MONITOR -2
5
MONITOR MODULE
MM
5
SK -PULL -SA
11
MANUAL PULL STATION
P
04
6
SPSR
28
SPEAKER/STROBE (WALL MOUNT)
)0(
7
SR
6
STROBE (WALL MOUNT)
0
8
SPSCR
28
SPEAKER/STROBE (CIELING MOUNT)
0
9
SK -PHOTO
1
PHOTOELECTRIC SMOKE SENSOR
10
PROVIDED BY OTHERS
1
WATER FLOW SWITCH
WF
11
PROVIDED BY OTHERS
5
TAMPER SWITCH
T
C
12
SSM24-8
1
8" BELL
13
SK -DUCT
4
DUCT DETECTORS
_
14
5860R
1
REMOTE FIRE ALARM ANNUNCIATOR
ANN
15
12V -18A
1
12VOLT 18 AMP HOUR BATTERIES
BATT
� -1 110CD
�/ 2W
❑
< B,C >
110CD
2W
ST -RAGE
RAG
B,C
11
EOL
75CD
2W
0 0
\
110CD
2W
TO FA2 1
3
A
110CD
1W
B.0
\TRY
<ITCHE
N
i4
i
z
0
1
P4
SUBMITTAL DRAWING
T) (C7 x
co
N
0
0
N
0
z
0
0
0
0
CID
DWG BY: JS
ENG BY: JS
CHK BY: JM
APP BY: JM
SCALE: 1/8"=1'
DRAWING NUMBER:
13 -JAS -01
OF
DATE:
10/1/13
PAGE:
FA1
WIRE GUIDE
,IDENTIFIER
DESCRIPTION
WIRE TYPE
A
SLC CIRCUIT
16/2 FPLP
B
NAC CIRCUIT
12/2 FPLP
C
VOICE NOTIFICATION CIRCUIT
12/2 FPLP SHIELDED
D
SBUS CIRCUIT
16/4 FPLP
1
MATCHNORTH FA2
LINE — =O i Ai
110
Or
ASSR
1/2W M
v
CLASSR
30CD M
1/2\N A
LASS
R
B
3
RI\TI
EEICL
75CD
EOL
L_...
19W
B,C
(7,1ll��o (fPlaowil
t FA -12--VP0-D //Li vi
K—o
0110CD
2W
75CD
�l F\
V
15CD
\S
S
B.0
gC
110CD
2W
EEICE
CD\
EEICL
FERE
CL
ST_R
2LASSR_❑
v
11OCD 0
2W
CLASSR
30CD
1/2W
3000
1/2W
o` l .
B
30CD
1/2W
EOL
❑I�/ " < Bc >
CLASSR
THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OF INFINITY FIRE PROTECTION LLC.
ALL RIGHTS ARE EXPRESSLY RESERVED. IT IS SUBMITTED UNDER A TRUST RELATIONSHIP FOR YOUR
USE IN CONSIDERING THE PURCHASE OF THE EQUIPMENT DESCRIBED HEREON FROM INFINITY FIRE
PROTECTION LLC. THIS DRAWING IS NOT TO BE USED FOR ANY OTHER PURPOSE NOR COPIED IN
WHOLE OR PART NOR ITS DESIGN FEATURES USED IN OTHER PRODUCTS WITHOUT OUR WRITTEN CONSENT.
IT IS TO BE RETURNED WHEN NO LONGER REQUIRED, OR UPON REQUEST.
LEGEND
ITEM
PART NUMBER
QTY.
DESCRIPTION
FACP
1
5280XL-EVS
1
FIRE ALARM CONTROL / VOICE EVACUATION CONTROL PANEL
AMP
2
EVS-50W
2
VOICE EVACUATION AMPLIFIER PANEL
SMAC
3
5495
1
SUPPLEMENTARY NOTIFICATION APPLIANCE CIRCUIT PANEL
MM
4
SK—MONITOR-2
5
MONITOR MODULE
P
5
SK -PULL -SA
11
MANUAL PULL STATION
CA
6
SPSR
28
SPEAKER/STROBE (WALL MOUNT)
/�\
7
SR
6
STROBE (WALL MOUNT)
0
8
SPSCR
28
SPEAKER/STROBE (CIELING MOUNT)
0
9
SK -PHOTO
1
PHOTOELECTRIC SMOKE SENSOR
WF
10
PROVIDED BY OTHERS
1
WATER FLOW SWITCH
T
11
PROVIDED BY OTHERS
5
TAMPER SWITCH
C
12
SSM24-8
1
8" BELL
13
SK -DUCT
4
DUCT DETECTORS
-1 1
ANN
14
5860R
1
REMOTE FIRE ALARM ANNUNCIATOR
BATT
15
12V -18A
1
12VOLT 18 AMP HOUR BATTERIES
1
v
30C)
1/2W
CLASS
v
75CD
1/2W
CLASSR
TO FA1
110CD
2W
110CD
2W
ASF-
(C<D
75CD EOL
2W
roL „l.
C E c s5'zo w
TO FA1
A.D
-t .‹
>
0
11 OCD
2W
1 /2W
L-U\G
A fad.
ti
e
wetz(<
75CD
v
1
E\S
SECURITY
Kd�
fly w
2-15,)22-
1)5,9
II,2 2-
3v-►
SACRIST1/
0
P
5TO FA3
110CD
2W
TO FACP
ST R
< B.0 >
B, c
ASCD f/
t.,
75CD
2W
u
B,C
0
0 75CD
2W
110CD
2W
TO FA3
\ARTHEX
< B,C
--t
110CD
2W
STO FA3
TO FA11
•
N Nr.
n
4,D0 N) O
w
co O
Cr) CC
CO ET_
><II
-z0I -.
o E -`z
Z
oixz
o
N _
eL
x �
•4
P1 co
z
0
cif)
z
cfj
F.T.1
z
0
SUBMITTAL DRAWING
w
0
z
0
DWG BY: JS
ENG BY: JS
APP BY: JM
SCALE: 1/8"=1'
CHK BY: KR
DRAWING NUMBER:
13 -JAS -01
))
0
OF
DATE:
12/26/07
PAGE:
FA2
WIRE GUIDE
IDENTIFIER
DESCRIPTION
WIRE TYPE
A
SLC CIRCUIT
16/2 FPLP
B
STROBE CIRCUIT
12/2 FPLP SHIELDED
C
VOICE NOTIFICATION CIRCUIT
12/2 FPLP
D
SBUS CIRCUIT
16/4 FPLP
5280XL-EVS
TO FA2
--MOM.,... —
v `"2W °
B
Dcr
115CD /\
2W
J
r
000
L
L
110CD
2W
TO FA1
110CD
2W
r
AMP
n
THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OF INFINITY FIRE PROTECTION LLC.
ALL RIGHTS ARE EXPRESSLY RESERVED. IT IS SUBMITTED UNDER A TRUST RELATIONSHIP FOR YOUR
USE IN CONSIDERING THE PURCHASE OF THE EQUIPMENT DESCRIBED HEREON FROM INFINITY FIRE
PROTECTION LLC. THIS DRAWING IS NOT TO BE USED FOR ANY OTHER PURPOSE NOR COPIED IN
WHOLE OR PART NOR ITS DESIGN FEATURES USED IN OTHER PRODUCTS WITHOUT OUR WRITTEN CONSENT.
IT IS TO BE RETURNED WHEN NO LONGER REQUIRED, OR UPON REQUEST.
LEGEND
ITEM
PART NUMBER
QTY.
DESCRIPTION
FACP
1
5280XL-EVS
1
FIRE ALARM CONTROL / VOICE EVACUATION CONTROL PANEL
AMP
2
EVS-50W
2
VOICE EVACUATION AMPLIFIER PANEL
SNAC
3
5495
1
SUPPLEMENTARY NOTIFICATION APPLIANCE CIRCUIT PANEL
MM
4
SK -MONITOR -2
5
MONITOR MODULE
P
5
SK -PULL -SA
11
MANUAL PULL STATION
12/
6
SPSR
28
SPEAKER/STROBE (WALL MOUNT)
/o\
7
SR
6
STROBE (WALL MOUNT)
®
8
SPSCR
28
SPEAKER/STROBE (CIELING MOUNT)
So
9
SK -PHOTO
1
PHOTOELECTRIC SMOKE SENSOR
WF
10
PROVIDED BY OTHERS
1
WATER FLOW SWITCH
T
11
PROVIDED BY OTHERS
5
TAMPER SWITCH
(
12
SSM24-8
1
8" BELL
13
SK -DUCT
4
DUCT DETECTORS
ANN
14
5860R
1
REMOTE FIRE ALARM ANNUNCIATOR
BATT
15
12V -18A
1
12VOLT 18 AMP HOUR BATTERIES
c0 ')
)N
oOro0
CO
I U.
-corny
rn�
I=-Zo1 Z
I
O .-11-
z
Z
ww3
CDCYZ
N
m
0
mft
CO
00
C:4 a:
w��
cir)
z
Z
m
V)
,�OD!Z ?O i)T
ro
0
(24
w
CD
Cf)
DWG BY: JS
ENG BY: JS
CHK BY: KR
APP BY: JM
SCALE: 1/8"=1'
DRAWING NUMBER:
13 -JAS -01
OF
DATE:
12/26/07
PAGE:
FA3
•
• OEMENAL ALARM
O RUPERMORY
• rmwtrritousul
SY11111 POWER
[T] CI )
L iLC
(7)0 )LSC
SOMME
(
EH I>
0101 0-10:1_01 1LI - 'L
u. *t i pP11ci neo:
_
cit
-1*
P
a A e
SIM IN
■■■■■■■
IIRllll.11140
• 71
2.3
SUR OUT
WATERFLOW
(EXISTING)
4.7K
EOL
TAMPER SWITCHS
(EXISTING)
f
4.71(
EOL
•
•
75CD rph
1W
n
30CD
1/2W A
1/2W
1/2W
110CD
2W W
30CD
1/2W
30CD
1/2W
30CD I--((
1/2w
15CD
1 /4W
75CD
2W
30CD
2W
110CD
2W
30CD
1/2W
30CD
1/2W
15CD
30CD
1/2W
75CD
1W
STORAGE ROOM
AMPLIFIER BATTERY CALCULATIONS
A
0
•
4.71<
EOL
COMPONENTS
QTY.
STANDBY
CURRENT
ALARM 1
CURRENT
ALARM
CURRENT
EVS-50W
1
0.085A
TOTAL WATTS
0.525A
TOTAL WATTS
46
OA
0.085A
2.070A
TOTAL
0.085A
X STANDBY TIME
2.595A
TOTAL STANDBY CURRENT DRAW =
2.04 AH
0.085 AMPS
X STANDBY TIME
X ALARM TIME
24 HOURS
STANDBY AMP HOUR TOTAL =
0.1677 AH
2.04 AH
TOTAL ALARM CURRENT DRAW =
ALARM AMP -HOURS REQUIRED =
2.595 AMPS
X ALARM TIME
2.2077 AH
0.083 HOURS
ALARM AMP HOUR TOTAL =
MINIMUM BATTERY SIZE NEEDED:
0.2154 AH
STANDBY AMP -HOURS REQUIRED =
MANUAL PULL STATION
2.04 AH
ALARM AMP -HOURS REQUIRED =
SPSR
0.2154 AH
TOTAL AH REQUIRED =
A
2.2554 AH
X DE -RATING FACTOR
6
1.20 (20%)
MINIMUM BATTERY SIZE NEEDED:
8
2.7065 AH
. . r.- .-..-.-, r-... . AI .-. r . .ik ii i Tr r-, el f-
AI
A x111 TI11r
: U.
11 OCD
2W
75CD
2W
11 OCD
2W
110CD�-(
1W IM
75CD
2W
75CD
2W
110CD
2W
11 OCD
2W
110CD
2W
110CD
2W
4.71(
EOL
400 OW
❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑❑
V❑DEL 5495
O UTDUT 1
O UT
AUT 2
O UTDUT .3
O UTPUT 1
.r_
15CD
75CD
2W
75CD
2W
75CD
2W
110CD
2W
75CD
M
15CD
30CD
2W
30CD
1W
75CD
2W
110CD
4.7K
EOL
110CD
2W
75CD
2W
75CD
1/2W
110CD
2W
30CD
1/2W
30CD
1/2W
110CD
2W
30CD
1/2W A
30CD
1/2W
4.7K
EOL
110CD
2W
110CD
2W
115CD
2W
110CD
2W lM
110CD
2W
4.7K
EOL
110CD
2W
75CD
110CD
2W
110CD
2W
75CD
1/2W
30CD
1/2W
110CD
2W
30CD
1/2W
30CD
1/2W
30CD
1 /2W
75CD
2W
4.7K
EOL
RISER ROOM
AMPLIFIER BATTERY CALCULATIONS
COMPONENTS
QTY.
STANDBY
CURRENT
ALARM 1
CURRENT
EVS-50W
1
0.085A
0.525A
TOTAL WATTS
33.25
OA
1.496A
TOTAL
0.085A
2.021A
TOTAL STANDBY CURRENT DRAW =
0.085 AMPS
X STANDBY TIME
24 HOURS
STANDBY AMP HOUR TOTAL =
2.04 AH
TOTAL ALARM CURRENT DRAW =
2.021 AMPS
X ALARM TIME
0.083 HOURS
ALARM AMP HOUR TOTAL =
0.1677 AH
STANDBY AMP -HOURS REQUIRED =
2.04 AH
ALARM AMP -HOURS REQUIRED =
0.1677 AH
TOTAL AH REQUIRED =
2.2077 AH
X DE -RATING FACTOR _
1.20 (20%)
MINIMUM BATTERY SIZE NEEDED:
2.6492 AH
.. w r' 1 11K 11 1Tf-r r'1I- A I A ill A TI1 4 1
IVV It: U.UtS.J L UHLJ IVIIIVV IGJ VE /1LfifClVl
THIS DRAWING CONTAINS CONFIDENTIAL PROPRIETARY INFORMATION OF INFINITY. FIRE PROTECTION LLC.
ALL RIGHTS ARE EXPRESSLY RESERVED. IT IS SUBMITTED UNDER A TRUST RELATIONSHIP FOR YOUR
USE IN CONSIDERING THE PURCHASE OF THE EQUIPMENT DESCRIBED HEREON FROM INFINITY FIRE
PROTECTION LLC. THIS DRAWING IS NOT TO BE USED FOR ANY OTHER PURPOSE NOR COPIED IN
WHOLE OR PART NOR ITS DESIGN FEATURES USED IN OTHER PRODUCTS WITHOUT OUR WRITTEN CONSENT.
IT IS TO BE RETURNED WHEN NO LONGER REQUIRED, OR UPON REQUEST.
QTY.
QTY.
LEGEND
ITEM
PART NUMBER
QTY.
DESCRIPTION
SPSR
0.275A
0.4A
ALARM ' RELAY
1
FACP
1
5280XL-EVS
1
FIRE ALARM CONTROL / VOICE EVACUATION CONTROL PANEL
AMP
2
EVS-50W
2
VOICE EVACUATION AMPLIFIER PANEL
SNAC
3
5495
1
SUPPLEMENTARY NOTIFICATION APPLIANCE CIRCUIT PANEL
MM
4
SK -MONITOR -2
5
MONITOR MODULE
0.004125A
n
5
SK -PULL -SA
11
MANUAL PULL STATION
EK
6
SPSR
28
SPEAKER/STROBE (WALL MOUNT)
A
7
SR
6
STROBE (WALL MOUNT)
®
8
SPSCR
28
SPEAKER/STROBE (CIELING MOUNT)
SO
9
SK -PHOTO
1
PHOTOELECTRIC SMOKE SENSOR
WF
10
PROVIDED BY OTHERS
1
WATER FLOW SWITCH
T
11
PROVIDED BY OTHERS
5
TAMPER SWITCH
(
12
SSM24-8
1
8" BELL
13
SK -DUCT
4
DUCT DETECTORS
1
ANN
14
5860R
1
REMOTE FIRE ALARM ANNUNCIATOR
BATT
15
12V -18A
1
12VOLT 18 AMP HOUR BATTERIES
0
FACP BATTERY CALCULATIONS
COMPONENTS
QTY.
QTY.
STANDBY
CURRENT
ALARM
CURRENT
5820XL-EVS FACP
1
CIRCUIT 1
SPSR
0.275A
0.4A
ALARM ' RELAY
1
OA "
OA
TROUBLE RELAY
1
.632A
OA
OA
2
30
SUPERVISORY
CURRENT
ALARM
CURRENT
PULL STATIONS
11
0.000375A
0.000375A
0.004125A
0.004125A
DUCT DETECTOR
4
0.00027A
0.00027A
0.00108A
0.00108A
ANNUCIATOR
1
0.02A
0.025A
0.02A
0.025A
EVS50 VOICE AMP
2
0.01A
0.01A
0.02A
0.02A
SMOKE DETECTOR
1
0.0003A
0.0003A
0.0003A
0.0003A
MONITOR MODULE
5
0.00075A
0.00075A
0.000375A
0.000375A
VOICE MODULE
1
0.07A
0.1A
0.07A
0.1A
ZONE 1 INPUT
1
0.015A
0.015A
0.015A
0.015A
ZONE 2 INPUT
1
0.015A
0.15A
0.015A
0.15A
STANDBY
CURRENT
ALARM
CURRENT
NAC CKT 1
0
1.856
OA
1.856A
NAC CKT 2
0
1.888
OA
1.888A
NAC CKT 3
0
0.0
OA
0.000A
1-0TAL
0.4209A
4.4599A
TOTAL STANDBY CURRENT DRAW =
0.4209 AMPS
X STANDBY TIME
24 HOURS
STANDBY AMP HOUR TOTAL =
10.102 AH
TOTAL ALARM CURRENT DRAW =
4.4599 AMPS
X ALARM TIME
0.083 HOURS
ALARM AMP HOUR TOTAL =
0.3702 AH
STANDBY AMP -HOURS REQUIRED =
10.102 AH
ALARM AMP -HOURS REQUIRED =
0.3702 AH
TOTAL AH REQUIRED =
10.4722 AH
X DE -RATING FACTOR
1.20 (20%)
MINIMUM BATTERY SIZE NEEDED:
12.5667 AH
2
SNAC BATTERY CALCULATIONS
`CIRCUIT
DEVICE
QTY.
CANDELAS
CURRENT
DRAW
TOTAL
CURRENT
CIRCUIT C
TOTAL
CIRCUIT 1
SPSR
1
110
.202A
.202A
SPSCR
4
75
.158A
.632A
SPSCR
2
30
•.094A
.188A
SR
1
75
.158A
.158A
SR
2
15
.066A
.132A
SSM24-8
1
.331A
.331A
1.64A
CIRCUIT 2
SPSCR
3
110
.202A
.606A
SPSCR
1
-75
.158A
.158A
SPSR
1
75
.158A
.158A
SPSR
4
30
.094A
.376A
1.3A
CIRCUIT 3
SPSR
1
115
.210A
.210A
SPSR
4
110
.202A
.808A
1.02A
CIRCUIT 4
SPSCR
4
110
.202A
.808A
SPSCR
1
75
.158A
.158A
SPSR
2
75
..158A
.316A
SPSR
4
30
.094A
.376A
1.66A
TOTAL
5.63A
TOTAL STANDBY CURRENT DRAW =
0.075 AMPS
X STANDBY TIME
24 HOURS
STANDBY AMP HOUR TOTAL =
1.8 AH
TOTAL ALARM CURRENT DRAW =
5.58 AMPS
X ALARM TIME
0.083 HOURS
ALARM AMP HOUR TOTAL =
0.485 AH
STANDBY AMP -HOURS REQUIRED =
1.8 AMPS
ALARM AMP -HOURS REQUIRED =
0.485 AH
TOTAL AH REQUIRED =
2.284 AH
X DE -RATING FACTOR
1.20 (20%)
MINIMUM BATTERY SIZE NEEDED:
2.74 AH
. -- .-. ... r_ .. . .... . -.. . -
IVU I : U.UZ5.7 tUUHLJ MIIV.
c0 j .
N
GV)
DO
W°O I U
(naaj
w cY)00E
>QII
1-- ZI -
I
0 I
r Z
w LIJ
oN.�
r a
who
F7-1
€-1z
cfrj
E-4
SUBMITTAL DRAWING
0
z
0
UD
E:11 E';"(
w � �
g) cA3
DWG BY: JS
ENG BY: JS
CHK BY: KR
APP BY: JM
SCALE: NOT TO SCALE
DRAWING NUMBER:
1 3 -JAS -01
OF
DATE:
PAGE: