Loading...
HomeMy WebLinkAboutPP - 7200 S 180TH ST - LOTTO-SHELLAN BUILDING - PERMITS AND PLANS7200 S 180TH ST ASSOCIATED PERMITS 14-F-088 13-F-098 14-F-172 11-F-078 FIRE ALARM LEGEND NEW EXIST SYMBOL DESCRIPTION MANUFACTURER PART # MOUNTING 0 1 FIRE ALARM CONTROL PANEL - EXISTING FIRE -LITE MS -9200 FACP 0 8 O SMOKE DETECTOR - EXISTING EXISTING 0 3HORN/STROBE �4 XX - WALL MOUNT XX - INDICATES DEVICE CANDELA SETTING /'E' INDICATES EXISTING DEVICE EXISTING E DENOTES EXISTING DEVICE SCOPE OF WORK: 1) RE—USE AND RELOCATE EXISTING SMOKE DETECTORS. NO NEW DETECTORS ADDED TO THE EXISTING SYSTEM. 2) RE—USE AND RELOCATE EXISTING AUDIBLE/VISUAL DEVICES. NO NEW AUDIBLE/VISUAL DEVICES ADDED TO THE EXISTING SYSTEM. HOOD ABOVE FIRE ALARM PLAN Scale: 1/8"=1'-0" w S SITE PLAN Scale: NTS N S W.thcat. Comments 1%,'; r Red 0 Per I n e Attached Letter Mege Oro 5 h ave bwe re reviewed by The TukwiEa Fre 3regentior► Bureau for cororrnance with current City raridardg, Acce f ,, << is subject to errors and ,mistdong which do nu authorize violations of adopted ;t; ndards and ordinana.s. The responsibility for the adetititty of design rests totally with the designer. Additions; deletions or revisions to these drawings after this date will void this acceptance and will require a resubrttfttal of revised drawings for subsequent approval. Final be ptanre is subject to field test and inspection by The 1Ukwila Fire Prevention Bureau. TUKWILA FIRE DEPARTMENT Please EPART dEl 1 - Please call 206-575-4107 and give this Fire Permit No. and exact address for r shut- down or restoration approval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing PAID APR 23 2013 I.UKWILA, FIRE. ►-4 FIRE ALARM SYSTEM - SUITE #4 TENANT IMPROVEMENT LU LU 0 W W CC CO CO T CO 0) ®0 = F— O Z H uir— can O < C1 H c\IO DESCRIPTION tn 44 PROJ. MGR.: Andrew Earle DRAFTER: HEW SHEET NO. 1 OF 1 TO FACP NAc *Z I6 /4 FPLR To FACE NAC # Ib /4- FPLR 7 TO FACP ZONE 18 /4" FPLR MECHNICAL NO WORK 75cd r5cd w"! CD WOMEN'S NO WORK S AFF STORAGE EXISTING 1 -HR RATE CORRIDOR NO WORK I OFFICE NO WORK FIL: (N.1 SERVER 109 EXISTING COLUMN, SEE DETAIL _ l i FOR FINISH WRAP l 555 ca, Eco. - RECEPTION .4) EQUAL PE G EXAM NEW WALL WITH EXISTI • ALIGN C{ OF WALL WITH THE OF WINDOW MULLION. T.I. FLOOR PLAN INFILL EXIST. WINDOW OPENING •/ 22x34-1/4"=1'-0" 11x17-1/8"= 1'4:r" SCALE -- I/8" = 1 Q g LEGEND EXISTING WALL TO REMAIN NEW 3 1/2"METAL STUDS, 25 GA. re 16" O.C. WALL WITH 5/8" GWB EA. SDE NOTE: PROVIDE SOUND INSULATION MALL NEW PARTITION WALLS. DOOR SCHEDULE DOOR N0. SIZE 100A 100B 101 102 103 3'-0" x 7.47x 1 3/4"PR 3'4" x 7..0"x 13/4" 3'.0"x 7'-0"x 13/4" 3.-0"x 7'-0"x 1 3/4" 3'.0"x 7%0"x 13/4" 104 3=6" x 747x 1 3/4" 105A 3'-0"x 7'41"x 13/4" 1058 3'•6"x7' -0"x 1 3/4" 106A • EXISTING DOOR 1068 107 108 109 110 112 113 3'.0"4 7'.0" x 13/4" 3'-0' x 7%0" x 13/4" 341"x 7.-0"x 13/4" DETAIL LABEL HDW FRAME REMARKS TYPE MAT FIN GU SHEET HEAD JAMB GRP MAT FIN TYPE TEMP A B B B B 8 8 8 8 8 B 3.-0"x 7'.0"x 13/4" B 347'x 7'-0"x 13/4" 8 1E4 3 -0"x7' -0"x 13/4' 3'.0"x 7.-0"x 1314" 3' -0"x7' -0"x 13/4 B WD WD WD WD wo WD WD WD Wo WD WD WD WD WD 8 WD ST ST ST ST ST ST ST ST 5T ST ST ST 5T ST ST B WD ST ABBREVIATIONS ALUM ALUMINUM HM HOLLOW METAL F.F. FACTORY FINISH 20 MIN POCKET DOOR 20 MIN PT ST WD PAINT STAIN WOOD ROOM FINISH SCHEDULE RM NO. 100 101 102 103 104 105 ROOM NAME WAITING EXAM EXAM EXAM EXAM EXAM 106 107 108 OFFICE EXAM EXAM 109 110 111 SERVER UNISEX LAB FLOOR MAT SV SV SV SV SV CPT SV SV SV SV SV 112 RECEPTION CPT 113 114 STAFF CPT/SV STORAGE 115 HALL SV TEMP TEMPERED PR PAIR FIN F.F. F.F. F.F. F.F. F.F. F.F. F.F. F.F. F.F. F.F. F.F. F.F. F.F. F.F. F.F. ABBREVIATIONS SV ACT ACOUSTICAL CEIUNG TILE CPT CARPET CONC CONCRETE F.F. FACTORY FINISH • GW8 GYPSUM WALLBOARD F.F. BASE MAT WD SV SV SV SV SV WD SV SV RB SV SV WD R8 RB SV 0114 ST F.F. F.F. F.F. F.F. F.F. S1 F.F. F.F. F.F. F.F. F.F. ST F.F. F.F. WALLS MAT GWB GW¢ GWB GWB GWB GWB GW8 GWB GWB GWB GWB/PW.t GW8 GWB GW8 GW8 FIN PT PT PT P1 PT PT PT PT PT PT PT PT PT PT PT F.F. GW8 PT CEILING MAT ACT/GWB ACT ACT ACT ACT ACT ACT ACT ACT ACT ACT ACT ACT ACT ACT ACT FIN PT F.F. F.F. F.F. F.F. F.F. F.F. F.F. F.F. F.F. F.F. F.F. F.F. F.F. F.F. PLYWD PLYWOOD P.LAM PLASTIC LAMINATE PT PAINT SV SHEET VINYL RB RUBBER BASE TILE HT EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. TILE: UNITED TILE. "NATIONAL PARKS BY LEA",18.9"x 18,9' SHEET VINYL: MANNINGTON COMMERCIAL, "CUSTOMSPEC If' SEAMS TO BE CHEMICALLY SEALED RUBBER BASE: JOHNSONIIE CARPET: PATCRAFT THE ARCHIVE SERIES. "CURATOR" A g DOOR TYPES Q22x34.1/4"=1"-0' xMOTES IFASPEREDGUSS1S,vLnGt-tul 11x17_ -1/B"= r-cr ANN I REMARKS 6" INTEGRAL COVE BASE 6 INTEGRAL COVE BASE 6 "INTEGRAL COVE BASE "INTEGRAL COVE BASE "INTEGRAL COVE BASE 6" INTEGRAL COVE BASE 6" INTEGRAL COVE BASE 6" INTEGRAL COVE BASE 6"INTEGRAL COVE BASE 6" INTEGRAL COVE BASE NOTES: I. REPLACE EXISTING ACOUSTICAL CEILING PANELS WITH NEW. 2. EXISTING GRID CEILING TO REMAIN NEW WORK IN PLACEREQUIRES UNLESS REMOVAL, SUCH AS OVER O Z Q NEW RECEPTION COUNTER. v7 w Z o 1n w 0 ° Ce le °Z = urco ooE> OE WQ'. • o Z8 ° = N 0 0 N 0 f.L. Att A72C 0) c3) (2) (a) (3) CIS) (3) (32) 179 A INA s, p.s. 1220 Taco 9:25 Ear ;TSuite C or) 98444 3.537.6542 irlcino.com I MICHAEL CINA SWFOF WASMOR: 1 U N Z Z 0 Z Job TT: Date: March 3, 2011 Revs: LEGEND CONTROL UNIT ANNUNCIATOR o SMOKE DETECTOR ® HEAT DETECTOR HORN STROBE C MANUAL PULL A HEAT DET. ABOVE CEILING CEILING- HORN STROBE IAAN I ,-- FACP" GROUND 7V. BAT. RISER V. B7VAYJ ,AAN 1 O Without Comments R' As Noted in Red ® Per The Attached Letter "hese plans have been reviewed by The Tukwila Fire 'revention Bureau frir conformance with current City -Y.,nC;ards. Acceg:; c is; :;I_Ih ect to errors and Aiss!ons which ll ; :; : ri' rr ize violations of adopted •i:andards and n1 Ir{,r, .- responsibility for the dequacy of der r, l . with doe d1 signer. Additions, deletions r, to these drawings after this date 'viii vold th cc.ptr nce and will require a resubmittal of r>: vise l drawil gs for sr.ibsequent approval. Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: �l " /a 'I ( • By:__AL,vLai V1.ttlik j retv4 OIev;CeS d t iot"`'Tttn ,-" 01, OLA 1 USA.. ,4-t , i hti .l-ihS Gievi c.c i') 6.e t?c'k * ea /IA.0o I. TA levv0.201.to ; S e i i •evt l 4-A,wv5tio k k L -c 7 j rls V 2rJ y ►^E:n kev" VG.,t ‘." 6,ecott, -. Z 11 1144- q/ I Vt6= %►/ Oto Wei 1%14N I t , 2i NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Test/pg of any Fire Alarm Detection Systems. re of test will result in a :R► -inspection Fee and termination of the testing. , UM 4% ORE DEPARTi%ENX Pleas ralI: 575-440Z give this job No. / 1—F- 07g and exact address for shuts • "•aiwn or restoration annrnki11 r-14 PAID MAR 31 2011 TUKWILA FIRE 74), , APR 12 2011 TUKWILA FIRE ",f X70 a f CP Ce C"1 E-4 501 Wy o 4 I ran 114 OA CI a N O c 0 0 (354- Z =1- u z Uz Z < zQ Q c z w Q 0 z per," LLJ Z W-- I— < z C:O t-- 0.....�.... Z u') OcD N W 0 Job #: Date: March 3, 2011 Revs: A.1.O Voltage Drop Analysis AJ Pc* 2- FireLite MS-9200UDLS Control Panel with XRM-24 (2.5 -amp • Notification Appliances Source Voltage: 20.40 VDC Low Line Protected Premises: Date: Address: City: State: Zip: Note: 7/29/2003 Prepared By: Phone: Address: City: State: Zip: Device # PartNumber Current (amps) Distance (Feet) Circuit Voltage @ Each Device Between Total 10 AWG 12 AWG 14 AWG 16 AWG 18 AWG 1 GCC24CR15 0.2280 16 16 20.34 20.28 20.23 20.14 19.98 2 GCC24CR15 0.2280 40 56 20.19 20.03 19.87 19.56 19.06 3 GCC24CR15 0.2280 6 62 20.18 20.00 19.82 19.48 18.94 4 GCC24CR15 0.2280 16 78 20.13 19.92 19.71 19.31 18.67 5 NS -241575W -FR 0.1740 14 92 20.10 19.87 19.63 19.18 18.47 6 GCC24CR15 0.2280 8 100 20.09 19.84 19.59 19.12 18.38 7 GCC24CR15 0.2280 14 114 20.07 19.81 19.54 19.05 18.25 8 GCC24CR15 0.2280 8 122 20.06 19.79 19.52 19.02 18.21 9 GCC24CR15 0.2280 8 130 20.06 19.79 19.51 19.00 18.18 Total Current: 1.9980 % Voltage Drop: 1.67 3.01 4.35 6.86 10.87 Go Go Go Go Go • Stpiketlyeugh indicates a value below the device's minimum voltage at indicated location and wire gauge. These calculations assume a worst-case source voltage as measured by UL with the batteries depleted to 20.4 volts. Under AC power and for most of the drain cycle of the batteries, the circuit voltages will be substantially higher and thus, would support a greater number of devices. A device's minimum operating voltage is derived from the UL -requirement that it work down to 80% of its rated (published) minimum operating voltage. Voltage Drop Analysis NA c. FireLite MS-9200UDLS Control Panel with XRM-24 (2.5 -amp • Notification Appliances Source Voltage: 20.40 VDC Low Line Protected Premises: Date: Address: City: State: Zip: Note: 7t29/2003 Prepared By: Phone: Address: City: State: Zip: Device # PartNumber Current (amps) Distance (Feet) Circuit Voltage @ Each Device Between Total 10 AWG 12 AWG 14 AWG 16 AWG 18 AWG 1 NS -241575W -FW 0.1740 5 5 2038 20.36 20.34 20.30 20.24 2 NS -241575W -FW 0.1740 1 6 20.37 20.35 20.32 20.28 20.21 3 NS -241575W -FW 0.1740 10 16 20.33 20.27 20.22 20.11 19.94 4 NS -241575W -FW 0.1740 13 29 20.28 20.18 20.09 19.91 19.62 5 NS -241575W -FW 0.1740 17 46 20.22 20.08 19.93 19.66 19.23 6 NS -241575W -FW 0.1740 1 47 20.22 20.07 19.92 19.65 19.21 7 NS -241575W -FW 0.1740 24 71 , 20.15 19.95 19.75 19.38 18.78 8 NS -241575W -FW 0.1740 40 111 20.05 19.78 19.50 18.98 18.14 9 NS -241575W -FW 0.1740 1 112 20.05 19.77 19.49 18.97 18.13 10 NS -241575W -FW 0.1740 19 131 20.02 19.71 19.41 18.83 17.92 11 NS -241575W -FW 0.1740 1 132 20.02 19.71 19.40 18.83 17.91 12 NS -241575W -FW 0.1740 18 150 20.00 19.68 19.35 18.75 17.79 13 NS -241575W -FW 0.1740 18 168 19.99 19.65 19.32 18.70 17.70 14 NS -241575W -FW 0.1740 40 208 19.97 19.63 19.29 18.64 17.61 Total Current: 2.4360 % Voltage Drop: 2.10 3.78 5.46 8.62 13.66 Go Go Go Go Go Strikethfeugb indicates a value below the device's minimum voltage at indicated location and wire gauge. These calculations assume a worst-case source voltage as measured by UL with the batteries depleted to 20.4 volts. Under AC power and for most of the drain cycle of the batteries, the circuit voltages will be substantially higher and thus, would support a greater number of devices. A device's minimum operating voltage is derived from the UL -requirement that it work down to 80% of its rated (published) minimum operating voltage. ® Fire-ure Alarms MS-92000DLS Battery Calculation Secondary Power Source Requirements Standby Current (amps) Secondary Alarm Current (amps) Device Type Qty Current Draw Total Qty Current Draw Total Main Circuit Board 1 x 0.255000 = 0.255000 1 x 0.325000 = 0.325000 XRM-24 1 x 0.000000 = 0.000000 1 x 0.000000 = 0.000000 ACM-8RF 0 x 0.030000 = 0 x 0.158000 = ACM-16ATF 0 x 0.040000 = 0 x 0.056000 = ACM-32AF 0 x 0.040000 = 0 x 0.056000 = AEM-16ATF 0 x 0.002000 = 0 x 0.018000 = AEM-32AF 0 x 0.002000 = 0 x 0.018000 = AFM-16ATF 0 x 0.040000 = 0 x 0.056000 = AFM-32AF 0 x 0.040000 = 0 x 0.056000 = AFM-16AF 0 x 0.025000 = 0 x 0.065000 = IPDACT 0 x 0.100000 = 0 x 0.300000 = DACT-UD 0 x 0.040000 = 0 x 0.075000 = LDM-32F 0 x 0.040000 = 0 x 0.056000 = LDM-E32F 0 x 0.002000 = 0 x 0.018000 = LCD -80F 1 x 0.025000 = 0.025000 1 x 0.064000 = 0.064000 4XTMF 0 x 0.005000 = 0 x 0.011000 = 4 -Wire Smoke Detectors 0 x 0.000000 = 0 x 0.000000 = EOLR-1 0 x 0.020000 = 0 x 0.020000 = Addressable Devices BEAM355 0 x 0.002000 = BEAM355S 0 x 0.002000 = BEAM1224 0 x 0.017000 = SD300T 41 x 0.000300 = 0.012300 SD355 0 x 0.000300 = SD355T 0 x 0.000300 = AD355 0 x 0.000300 = H355 0 x 0.000300 = H355R 0 x 0.000300 = H355HT 0 x 0.000300 = D350P 0 x 0.000300 = D350RP 0 x 0.000300 = D350PL 0 x 0.000300 = D350RPL 0 x 0.000300 = MMF-300 0 x 0.000400 = MMF-300-10 0 x 0.003500 = MDF -300 0 x 0.000750 = MMF-301 0 x 0.000375 = MMF-302 0 x 0.000270 = MMF-302-6 0 x 0.002000 = BG-12LX 4 x 0.000230 = 0.000920 CMF -300 0 x 0.000390 = CMF -300-6 0 x 0.002250 CRF -300 0 x 0.000270 = CRF -300-6 0 x 0.001450 = 1300 0 x 0.000400 = System Sensor 5451 20 x 0.001000 = 0.020000 B501 BHT 0 x 0.001000 = B224RB 0 x 0.000500 = B224BI 0 x 0.000450 = Maximum draw for Addressable devices > 0.400000 alarm all ------ Miscellaneous Device 1 0 x 0.000000 = 0 I xl 0.000000 Miscellaneous Device 2 0 x 0.000000 = 0 I= I xl 0.000000 Miscellaneous Device 3 0 x 0.000000 = 0 x 0.000000 = Miscellaneous Device 4 0 x 0.000000 = 0 x 0.000000 = Miscellaneous Device 5 0 x 0.000000 = 0 x 0.000000 = NAC 1 14 x 0.148000 = 2.072000 NAC 2 9 x 0.270000 = 2.430000 NAC 3 0 x 0.000000 = NAC 4 0 x 0.000000 = Total Standby Load 0.313220 Total Alarm Load 5.291000 ®Flre•LIreALarrns MS-92000DLS Battery Calculation Note 1: You are fully responsible for verifying these calculations. Note 2: Use the dropdowns in the yellow cells to enter values. Calculation in Total Sheet MS 9200ODLS Control Panel: The output current is within the panel's limitations. Required Standby Time in Hours 24 Hours Standby Load Current 1 0.31322 Amps x 24 = 7.517 AH Required Alarm Time in Minutes 5 Minutes Alarm Load Current (Amps) 1 5.29100 Amps x 1 0.084 1= 0.444 AH Total Current Load 7.962 AH Multiply by the Derating Factor 1 1.2 1= x 1.20 Total Ampere Hours Required 9.55 AH Recommended Batteries: BAT -12120 - 12AH Batteries Battery Check The batteries can be charged by the MS-9200ODLS Charger. The batteries can be housed in the MS-9200ODLS Cabinet. Current Draw Check NAC#1 current is within the limitations of the circuit. NAC#2 current is within the limitations of the circuit. NAC#3 current is within the limitations of the circuit. NAC#4 current is within the limitations of the circuit. MS 9200ODLS Control Panel: The output current is within the panel's limitations. Fire eAL''ms by Honeywell Voltage Drop Analysis MS-9200UDLS Control Panel w/IIIRM-24B (2.5 -amp circuit) Notification Appliances - NAC #1 Source Voltage: 19.18 VDC Terminal Voltage Protected Premises: Date: Address: City: State: Zip: Note: 4/14/2008 Prepared By: Phone: Address: City: State: Zip: Device # Part Number Current (cps) Distance (Feet) Circuit Voltage @ Each Device Between Total 10 AWG 12 AWG 14 AWG 16 AWG 18 AWG 1 HSRC15 0.0820 18 18 19.14 19.12 19 09 " 19.04 18.96 2 HSRC15 0.0820 36 54 19.08 19.02 =18 93 18.78 18.55 3 HSRC15 0.0820 4 58 19.08 19.01 118,92. 18.76 18.51 4 HSRC15 0.0820 14 72 19.06 18.98 ................. 1887 ........... 18.68 18.39 5 HSR75 0.1480 12 84 19.04 18.9618 83 18.63 18.30 6 HSRC15 0.0820 8 9219.04 18.95 18,82..: 18.60 18.26 7 HSRC15 0.0820 14 106 19.03 18.94 >18 80 :: 18.57 18,21 8 HSRC15 0.0820 8 114 19.03 18.93 18.79 . 18.55 18.19 9 HSRC15 0.0820 8 122 19.02 18.93 1818 18.55 18.18 Total Current: 0.8040 % Voltage Drop: 0.81 1.30 2.07 3.29 5.23 Go Go Go Go Go Strikethreugh indicates a value below the device's minimum voltage at indicated location and wire gauge These calculations assume a worst-case source voltage as measured by UL with the batteries depleted to 20.4 volts. Under AC power and for most of the drain cycle of the batteries, the circuit voltages will be substantially higher and thus, would support a greater number of devices. A device's minimum operating voltage is derived from the UL -requirement that it operate within a Regulated Voltage Range (16VDC - 33VDC). 2014-08-18 1 eHreuTeAiarms by Honeywell Voltage Drop Analysis MS-9200UDLS Control Panel w/XRM-24B (2.5 -amp circuit) Notification Appliances - NAC #2 Source Voltage: 19.18 VDC Terminal Voltage Protected Premises: Date: Address: City: State: Zip: Note: 4/14/2008 Prepared By: Phone: Address: City: State: Zip: Device # Part Number Current (cps) Distance (Feet) Circuit Voltage (a, Each Device Between Total 10 AWG 12 AWG 14 AWG 16 AWG 18 AWG 1 HSRC15 0.0820 46 46 19.11 19.06 ;18 99' ;i 18.88 18.71 2 HSRC15 0.0820 10 56 19.09 19.04 1896::: 18.83 18.62 3 HSRC15 0.0820 14 70 19.08 19.01 18;92:;;;: 18.76 18.51 4 HSRC15 0.0820 8 78 19.07 19.00 1890 18.73 18.46 5 HSRC15 0.0820 12 9019.06 18.99 ..., 1887;; 18.69 18.40 6 HSRC15 0.0820 6 96 19.06 18.98 18 86 < 18.68 18.38 7 HSRC15 0.0820 6 102 19.05 18.98 18.86- 18.67 18.36 8 HSRC15 0.0820 6 108 19.05 18.98 .18 85 18.66 18.36 Total Current: 0.6560 % Voltage Drop: 0.67 1.07 1.70 2.70 4.29 Go Go Go Go Go Stfiketkeugh indicates a value below the device's minimum voltage at indicated location and wire gauge These calculations assume a worst-case source voltage as measured by UL with the batteries depleted to 20.4 volts. Under AC power and for most of the drain cycle of the batteries, the circuit voltages will be substantially higher and thus, would support a greater number of devices. A device's minimum operating voltage is derived from the UL -requirement that it operate within a Regulated Voltage Range (16VDC - 33VDC). 2014-08-18 1 .0 • efireirremarms by Honeywell Voltage Drop Analysis FCPS-24FS8 Power Supply (3.0 -amp circuit) Notification Appliances - NAC #1 Source Voltage: 19.20 VDC Terminal Voltage Protected Premises: Date: Address: City: State: Zip: Note: 4/14/2008 Prepared By: Phone: Address: City: State: Zip: Device # Part Number Current (amps) Distance (Feet) Circuit Voltage @ Each Device Between Total 10 AWG 12 AWG 14 AWG 16 AWG 18 AWG 1 HSR15 0.0820 6 6 19.18 19.16 >)914 `= 19.10 19.05 2 HSR75 0.1480 1 7 19.17 19.16 19,13 19.09 19.02 3 HSR15 0.0820 10 17 19.14 19.1019 04 .............: 18.95 18.81 4 HSR30 0.1020 20 37 19.08 19.00 1:::::18:88::'1 .................... 18.70 18.40 5 HSR30 0.1020 28 65 18.99 18.87 '' 186'' 18.36 17.87 6 HSR30 0.1020 1 66 18.99 18.87 ` "�18 67 .......... .................. 18.35 17.85 7 HSR30 0.1020 28 94 18.92 18.76 18.45f- is. 18.08 17.41 8 HSR75 0.1480 44 138 18.83 18.60 18..25...i. .................... ...................... 17.69 16.79 9 HSR75 0.1480 1 139 18.82 18.60 `' `18 24> : 17.68 16.78 10 HSR75 0.1480 20 159 18.79 18.55 ;18,17::;: . .............. 17.56 16.59 11 HSR30 0.1020 1 160 18.79 18.55 ................... .................. 1817 17.55 16.59 12 HSR15 0.0820 20 180 18.78 18.52 ;:1812 >. 17.48 16.47 13 HSR110 0.1970 20 200 18.76 18.50 18:09 : 17.43 16.39 14 HSR15 0.0820 32 232 18.76 18.49 I8.-.0.ti 17.40 16.35 Total Current: 1.6270 % Voltage Drop: 2.32 3.69 5.87 9.36 14.87 Go Go Go Go Go Sough indicates a value below the device's minimum voltage at indicated location and wire gauge These calculations assume a worst-case source voltage as measured by UL with the batteries depleted to 20.4 volts. Under AC power and for most of the drain cycle of the batteries, the circuit voltages will be substantially higher and thus, would support a greater number of devices. A device's minimum operating voltage is derived from the UL -requirement that it operate within a Regulated Voltage Range (16VDC - 33VDC). 2014-08-18 1 48 FirelfreAtarillS by Honeywell MS-92000DLS Rev.3 Battery Calculation Secondary Power Source Requirements Device Type Standby Current (amps) Secondary Alarm Current (amps) Qty Current Draw 1 Total Qty Current Draw Total Main Circuit Board 1 x 0.145000 = 0.145000 1 x 0.275000 = 0.275000 XRM-24B 0 x 0.000000 = 0 x 0.000000 = 4XTMF 0 x 0.005000 = 0 x 0.011000 = IPDACT-2 0 x 0.093000 = 0 x 0.136000 = IPDACT-2UD 0 x 0.098000 = 0 x 0.155000 = ECC-FFT 0 x 0.120000 = 0 x 0.230000 = ANN-BUS Devices ANN-80(-W) 0 x 0.015000 = 0 x 0.040000 = ANN-LED 0 x 0.028000 = 0 x 0.068000 = ANN-RLED 0 x 0.028000 = 0 x 0.068000 = ANN-RLY 0 x 0.015000 = 0 x 0.075000 = ANN-I/O 0 x 0.035000 = 0 x 0.200000 = ANN-S/PG 0 x 0.045000 = 0 x 0.045000 = ANN-LC 0 x 0.150000 = 0 x 0.150000 = ACS Annunciators ACM-8RF 0 x 0.030000 = 0 x 0.158000 = ACM-16ATF 0 x 0.040000 = 0 x 0.056000 = ACM-32AF 0 x 0.040000 = 0 x 0.056000 = AEM-16ATF 0 x 0.002000 = 0 x 0.018000 = AEM-32AF 0 x 0.002000 = 0 x 0.018000 = AFM-16ATF 0 x 0.040000 = 0 x 0.056000 = AFM-32AF 0 x 0.040000 = 0 x 0.056000 = AFM-16AF 0 x 0.025000 = 0 x 0.065000 = LDM-32F 0 x 0.040000 = 0 x 0.056000 = LDM-E32F 0 x 0.002000 = 0 x 0.018000 = LCD-80F 1 x 0.025000 = 0.025000 1 x 0.064000 = 0.064000 Addressable Devices BEAM355 0 x 0.002000 = BEAM355S 0 x 0.002000 = BEAM1224 0 x 0.017000 = CP355 0 x 0.000300 = SD355 35 x 0.000300 = 0.010500 SD355T 0 x 0.000300 = AD355 0 x 0.000300 = H355 17 x 0.000300 = 0.005100 H355R 0 x 0.000300 = H355HT 0 x 0.000300 = D350P 0 x 0.000300 = D35ORP 0 x 0.000300 = D350PL 0 x 0.000300 = D35ORPL 0 x 0.000300 = D355PL 0 x 0.000300 MMF-300 0 x 0.000400 = M M F-300-10 0 x 0.003500 = MDF-300 0 x 0.000750 = MMF-301 0 x 0.000375 = MMF-302 0 x 0.000270 = MMF-302-6 0 x 0.002000 = BG-12LX 4 x 0.000300 = 0.001200 CMF-300 0 x 0.000390 = CMF-300-6 0 x 0.002250 = CRF-300 0 x 0.000270 = CRF-300-6 0 x 0.001450 = CDRM-300 0 x 0.001300 = 1300 0 x 0.000400 = 8501 BH-2 0 x 0.001000 = B501 BHT-2 0 x 0.001000 = B224RB 0 x 0.000500 - B22461 0 x 0.000450 = B200SR 0 x 0.001000 = Uaximum alarm draw for all Addressable devices --------------> 0.400000 EOLR-1 0 x 0.020000 = 0 x 0.020000 = FCPS (Remote Sync) 0 x 0.021700 - Resettable Power 4 -Wire Smoke Detectors 0 x 0.000000 = 0 x 0.000000 = Auxiliary Power CMF -300 (Aux. Power) 0 x 0.001700 = 0 x 0.007000 = CMF -300-6 (Aux. Power) 0 x 0.008000 = 0 x 0.020000 = MMF-302 (Aux. Power) 0 x 0.012000 = 0 x 0.090000 = MMF-302-6 (Aux. Power) 0 x 0.050000 = 0 x 0.270000 - B200SR (Aux. Power) 0 x 0.000500 - 0 x 0.035000 = Miscellaneous Devices 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 - 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 = 0 x 0.000000 = Output Circuits NAC/Output #1 0.000000 = 1.080000 = 1.080000 NAC/Output #2 0.000000 = 0.960000 = 0.960000 NAC/Output #3 0.000000 = 0.000000 = NAC/Output #4 0.000000 = 0.000000 - Current Draw from 763 0.000000 = 0.000000 = Total Standby Load 0.186800 Total Alarm Load 2.779000 GiitlrettreAtarrns by Honeywell NAC#1 current is within the limitations of the circuit. MS-92000DLS Rev.3 Battery Calculation NAC#3 current is within the limitations of the circuit. NAC#4 current is within the limitations of the circuit Calculation in Total Sheet Required Standby Time in Hours 24. Hours Standby Load Current 0.18680 Amps x 24 = 4.483 AH Required Alarm Time in Minutes 5 Minutes Alarm Load Current (Amps) 1 2.77900 Amps x 0.084 1= 0.233 AH Total Current Load 4.717 AH Multiply by the Derating Factor I 1 2 j= x 1.20 Total Ampere Hours Required 5.66 AH Recommended Batterles: BAT -1270 - 7AH Batteries Battery Check The batteries can be charged by the MS-92000DLS Charger. The batteries can be housed in the MS-92000DLS Cabinet. Current Draw Check NAC#1 current is within the limitations of the circuit. NAC#2 current is within the limitations of the circuit. NAC#3 current is within the limitations of the circuit. NAC#4 current is within the limitations of the circuit MS 92000DLS Control Panel: The output current is within the panel's limitations. . . • Without Comments As Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire •::Irevention Bureau for conformance with current City ;randards-, AcceptaflCe is subject to errors and wissions which do not authorize violations of adopted 1 71ndards and ordinances. The responsibility for the 1 ,,,.tquacy of design rests.totally with the designer. ..7,dtions, deletions or revisions to these drawings after date %Mil void this acceptance and will require a ,,••,-,.:.:tibrolt.t..al of revised drawings for subsequent approval. al acceotane is subject to fleld test and inspection by le 'Tukwila Firt., Prevention Bur au. Late:1Q:1_i____Esy: ,5 )t- Ev4 vw2- vt-0,1erc- 1,441t. el41, 1108c it,.4 0, cial'icAq rAlp * T -C- hoA- qtv'extoll CLus. 1•101ti( C..,A. 04,1-• klio)4 kop6/4. a FIRE DEPARTMENT ji-'kia4t Ca 2K-5754407 and jvc this Fire Perifiit No. esci: mdrirtss for glut - down. Or rzsz1011 Eipproval. NOTICE A complete -d, signed, TukWila Fire Department Pre-test Certificate must be. presented to Ile fnspectOr prior to commencement of Acceptance Testina of any Fire Alarm and Dctection.Systems. • Failure of test will result in a Re -inspection Fee and. termination of the t,•sting TO FACP MOM 16/2 FPLR TO FACP ZONE 18/4 FPLR PHYSICAL THERAPY 30 ed 11 TREATMENT 2 1V-90 FLOOR PLAN SCALE = 1/8" = 1' — 0" ADDING (3) CEILING MOUNT SMOKE DETECTORS. ADDING (8) CEILING MOUNT HORN STROBES. PHYSICAL THERAPY ROOM HORN STROBE RELOCATED WITH IN ONE FOOT.. 04 LEGEND FIRE ALARM CONTROL PANEL X 32 EXIST SMOKE DETECTOR X 3 SMOKE DETECTOR X 17 EXIST HEAT DETECTOR. ABOVE CEILING X 23 EXIST HORN STROBE o X 8 CEILING MOUNT HORN STROBE X4 EXIST PULL STATION PAID AUG 1 2014 TUKWILA FIRE cc 0 •• 01 W• ••W 00 F... .4: co < .-- c° o LL..8 Dm 0 < • • (\I Lu X Z LcE 0 0) 5 x 0 0 17. Lu >- " v.k0 u 010 Cr 0 Cr > n 00 I0 *0 - CO 01 00 g4t 00 44t if) co #0".• 00 00 00 • • -c INTERVENTIONAL PAIN CLINIC 7200 SOUTH 180TH ST SUITE # 101 TUKWILA, WA 98188 FIRE ALARM PLAN A-1 FIRE PROTECTION, INC. PO BOX 12642 MILL CREEK, WA 98082 14251 290-9600 OR 1-800-681-1125 FAX 14251353-4546 April 11, 2014 City of Tukwila - PLAN REVIEW RE; FIRE ALARM SYSTEM Please find enclosed TI plans for a FIRE ALARM SYSTEM addition. Fire Protection, Inc. add/relocate devices per plan to the existing fire alarm system. The building is non -sprinkled. The system shall monitor by zone activation as well as separate trouble signals. Monitoring shall be provided via listed Central Station. Audibility shall be in compliance with NFPA standards. A full pre-test and NFPA form shall be conducted and completed prior to calling the AHJ for acceptance testing. INSTALLATION COMPANY Fire Protection, Inc. 1730 Gibson Rd. Everett, WA 98204 WSCL# FIREPI*021ML UL CERT #608242-002 JOB Site; WCPM 7200 S. 180th Street Suite #102 Tukwila, WA. CONTRACTUAL RESPONSIBLE PARTIES Installation; Fire Protection, Inc. AMBIENT TEMPERATURES No area with alarm service equipment shall fall below 40 degrees, common areas shall be at 68 degrees per builder AMBIENT NOISE RANGE All areas serviced by the Fire Alarm Control and notification system will be as listed for per UBC listings, per builder. SEQUENCE OF OPERATIONS All Alarm and Trouble conditions shall enunciate at FACP as well as remote notify listed Central Station. Zones of alarm shall cause for all notification circuits to activate, send alarm zone to CS, re -dispatch to Fire and dispatch FPI runner service. Trouble and supervisory signals shall transmit to CS which will dispatch FPI runner service to site, (no notification circuits shall activate.) On site emergency contact personnel shall be notified. Wet Waterflow ALARMS shall be retarded by a period of not more than 45 seconds. Low air shall activate at 251bs, causing for a supervisory signal. A short on FACP smoke, Waterflow Switches, (wet and dry) and pull station shall cause alarm. Shorts on PIV, tamper and Hi -low air zones shall cause a Supervisory condition. Opens on any zones shall cause for a trouble signal. Should you have any further questions, please feel free to contact me directly. Robert Vaughn Project Manager * *NICET-3 ##115522 * *SFD #SCPV-04243 CITY OF REDMOND DESIGNER OF RECORD ##10-B-113 8 7 6 5 4 3 2 1 #18 FPLR TO EXISTING FACP SLC ..metas Without Com in #18 FPLR Fire AlarmSymbol`ched Legend Q ■ As Noted Red Per. The Alta Letter SYMBOL. DESCRIPTION PART NUMBER 2SD-355 Smoke..Detector The TukwflaF ire: �'hse lar�5 ha ve been reviewed by_ P , I s nt C �, nformance with curreCity � 1 n'Bureau for co tc3'errors and �- .1 Yom` StUndards Acceptance is subject _..�.._ � "" NEW STAFF NEW INJECTION ` NEW HALL / ROOM INSTALLATION NOTES: Heat Detector HD -355 omissions which do not authorize violations of adopted '" ._......... NEW RESTROOM ''�'� ,, _ 1 NEW INJECTION Roots ,__ ili Addressable Pull Station B012LX enndards and ordinances. The responsibility for the c. totally with the designer: NO WORK IN EXISTING 'E' adequacy of design rests BUILDING - COMMON ARE .- pm ( }1 `✓ E . _;; i OE -DEVICES MARKED ARE EXISTING, TO REMAIN AS -IS b� Strobe, Standard CD, Red Additions deietlons or revisions to these drawings after this date will void this acceptance and will require a .O. G 1 75CD i s I 1 005 drawings for subsequent approval. NO ._._SC IN PE • $IG'1.003 - i# . . 91G1.004 .d,{c nco • StG1.006 -DEVICES MARKED 'EfR' ARE EXISTING- 2 Wire Horn/Strobe, Standard cd, Red resubmittal of revised to field test and inspection by I �% ,C c 3oco ,©, c 3oco RELOCATED TO LOCATIONS SHOWN. ® c Strobe, Standard DB, Ceiling Mount, RedTukwila Final acceptance Is subject The Fire Prevention Bureau. Horn/Strobe,Ceiling mount,Standard CD,Red `� ��-i B 51 1 I y nate. . _._......' .. III EOL 4.7K EOL #16 FPLR ( ..m...� � - ' I RPS i Power Supply 5495 TO RPS SIG1' .:;�� srGi•ao1 �7 'f #16 FPLR p �c 3QCQ 2 � E b,1 0=0'7 UiCWILA FIRE DEPARTMENT 1 1•►�r�p' Please call 206-575-4407 and NEW WAITING �. . l �'' cbSIG1 S1G1.00d, . C 3CD 1 give this Fire P rmr NEW WAITING I �• � N©• RECOVERY / y F- o Q s and 1 . exact address for shut - down or restoration EXIST JANITOR Z yaL Battery Calculations for Panel: 5495 OE 4.__ OE i NOTICE NEW OFFICE / Part No:5495 - 5495 NAC Power Extender Panel A Tukwila 016 FPLR1- !.-._ completed, signed, TO RPS SIG2 f ,__EXIST �„. I � STOR. NEW MA 30GDi-E~` Job number: 1 Job name: Drawing/ Fire Department Pre-test #16 FPLR 0 �:�� .s LAB 1 � , _ Part No. Qty. y Description pt n: Standby. Total Standby Alarm Total Alarm Certificate must be presented .: sr lqt0 . , 4 Panel Equipment ,� the Inspector prior to � p I 30CD .commencementof 5495B 1 '5495 Power Extender Panel MainMother Board Acceptance H _ ;: • • , A;>m 75.0000mA 75.00 A -; 1 5.0000 7 mA 175:p �OmA • 15fT � �Testingof TotatPanelStb , 75.0000mA� 'Total Panel Alarm.: 175.Ot�OmA ' anyFire Alarm _ , ____ -� :�. lPeripheral OFFICE Devices and Detection Systems. r EXAM EXAM SCR 6 Strobe,Standard DB,CeilingMount, Red Notification (Notification) O.00OOtnA O.00gOmA 77.0000mA 462.00OOmA Failure of test will result SCR 5 Strobe,Standard DB,CeilingMount, Red(Nofrfication) O.Ot�OmA O.�OmA '94.0000rnA 470.0000mA ' Re - inspection � Re mspectlon Fee`and NEw SEG `noN j e 2 QEtermination �,, PC2R ` 3 Ham/Strobe Ceilingmount,Standard CD, Red (Notification) O.Q�mA 0.0000mA rr 107.0000mA ' 321.00OQtnA the testing ', SIG7: 03 � EOL 2 EOL 4.7K (Notification) 0.0000mA 0.0000mA 0.0000mA 0.0000mA of � ® :'E C 30CD' E ,.;..� 1 , �. 0 !?'Lt ire ;_ Total Peripheral Stay 0.0000mA Total Periph Alarm 1253.0000mA ' _-_ 2� E �_ Total Standby Amps 75.0000mA Total Alarm Amps 1428.0000mA \\ may' Sto2•oo2 ? NO WORK BUILDING IN EXISTING - COMMON AREA _. ;` 3oco- e • H .. c 30Ca _... 3oco a •111 �' Standbytime: 24 Hrs 1.8Ah Alarm time: 5 Min 0.119Ah E� �, t3 3tG2 i ' ; E Battery requirement: 1.919Ah Compensation Factors - Standby: 1.2 Alarm: 1.2 Requirement with compensation: 2.303Ah .. srcz * _ _. , slccfa� . C 30CD E .-._: f .�. C 1575CD .�. s• C 15X5GEi p�q 12VDC 7Ah BACK-UP BATTERIES TO BE USED I E Mel I r - . , _ 1 Z E I NEW NEW OFFICE ; { . -_-- _EXAM EXAM . ....,,,.EXAM, .�.EXAM Circuit Calculations Panel.. 5495 Card: 00 Crrcurt, I 1Circuit Calculations Panel: 5495 Card: 00 Circuit:SIG2 Ci rcultNarne. SIG1 Circuit Type: Notification/24V DC Terminal Voltage: 20.2V:DC Amperage: 3.0000mACircuit Cable. Fowey, Limited, Multiple Conductor #14 P__ Calculations based on RunningLength.Calculations'Total Design Criteria: Ambient temIature:167°F Max. operating voltagedrop: 10% Job number: 1 Job name: Drawingl CircuitName: SIG2 Type:Notificationl2dV DC Terminal Voltage: 20.2V:DC Amperage: 3.0000mA Cable: Power,Limited,Mu Multiple Conductor #14 based on Running Total Length. Design Criteria: Ambient temperature: 167 F Max. operatingvoltage drop: 10% Job number: 1 Job name: Drawing/ Device Part No Appliance Desc Distance Current Voltage Voltage Drop Device Part No Appliance Desc Distance Current Voltage Voltage Drop 5495 Panel 20.2V 5495 Panel 20.2V 001 PC2R Horn/Sirobe, Ceiling mount, Standard CD, Red, 30CD 72'-0 107.0000mA 19.8445V (0.3555V) 001 SCR Strobe, Standard DB, Ceiling Mount, Red, 1575CD 89'-0 77.0000mA 19.928V (0.272V) 002 SCR Strobe, Standard DB, Ceiling Mount, Red, 1575CD 17-0 77.0000mA 19.7721V (0.0723V) 002 SCR Strobe, Standard DB, Ceiling Mount, Red, 30CD 24'-0 94.0000mA 19,8865V (0.0818V) j� 003 SCR Strobe, Standard DB, Ceiling Mount, Red, 30CD 10'-0 94.0000mA 19.7345V (0.0376V) 003 SCR Strobe, Standard DB, Ceiling Mount, Red, 1575CD 21'-0 77.0000mA 19,8252V (0.0413V) V 004 SCR Strobe, Standard DB, Ceiling Mount, Red, 30CD 16-0 94.0000mA 19.6838V (0.0508V) 004 SCR Strobe, Standard DB, Ceiling Mount, Red, 1575CD 32'-0 77.0000mA 19.778V (0.0472V) 005 PC2R Horn/Strobe, Ceiling mount, Standard CD, Red, 30CD 12'-0 107.0000mA 19.6531V (0.0308V) 005 SCR Strobe, Standard DB, Ceiling Mount, Red, 1575CD 10`-0 77.0000mA 19.7682V (0.0098V) Q06 SCR • , Strobe, Standard OB, Ceiling Mount, Red, 30CD 15.0 94.o0�mA 19.62481 (4.028211 006 SCR Strobe, Standard D6 Ceiling Mount` Red 1575CD ' 9 8' 0 77.O�OmA 19:76431 0.003.9 { V) 007 PC2R Horn/Strabe, Ceiling mount, Standard CD, Red, 30CD 14.-0 107.0000mA 19.60691 (0.018V), -01 ; EOL EOL 4.7K 2 .0 0.0000 mA 6 1 9 .76431 (OV) 0018V-0 8 SCR Strobe Standard DB, Ce Mount, Red, 30CD 29-0 94.0000mA 19.5895V (0.01741) 479.0000mA C 1575CD C 1575CD` C 1575CD C 1575CD C 30CD G1575CD EXISTING, FRCP -01Total EOL EOL 4.7K '' 2 -0 ' 0.0000mA 19:58951 0 { v} Current: o t OOOOmA -(Total 1$T 0 774.0000mA VD op Percent:2.18% Total to: P ) o I Voltage Drop 0.43571 >'� �• • • �• �• • Ci iii h P ^, Total Current. 774.000OmA c� 01,ti (Total VDrop Percent:3.02%) Total Voltage Drop : 0:81051 C 30CD C 30CD C 30CD yec C 30CD y C 30CD �. C 30CD C 1575CD C 30CD 5495 `'� h * .:�•`p RPS LOCATED IN EXISTING y�' �� y� y�c� • y�� '5 FIRE ALARM CONTROL ROOM A DRAWN BY: ROBERT VAUGHN * L 8, 1 #VAUGHR 981 Q4 SEATTLE#SCPV-04243 FIRE DEPT. #SCPV 04243 `. FIRE ALARM TI NICET III #115522 -D CITY'OF REDMOND DESIGNER OF RECORD #10-B-113Everett PROPERTY OF AND ALL RIGHTS R HT RESERVED FIRE PROTECTION INC DATE: 4/18/2014 FIRE PROTECTION INC. 1730 Gibson n'- G bS© Road WA. 98204 425-290-9600: ' WCPM TUKWILA 7200 STREET S 180TH TRE T SUITE #102 TUKWILA, WA. FIREPI*021 ML SIZE D FSCM NO. DWG NO. FA 1.0 REV 1 RA SCALE 118" = 1' 0" SHEET APR r 8 7 6 5 4 3 2 1 -f�UK�'VI(-� ID 2014 etFIRE '22/