Loading...
HomeMy WebLinkAboutPP - 13017 56TH AVE S - RESIDENCE - PERMITS AND PLANS13017 56TH AVE S ASSOCIATED PERMITS 16-5-103 SITE PLAN BUILDING CROSS SECTION DESIGN CRITERIA SCOPE OF WORK FOSTER POINT 6 CARY LANG CONSTRUCTION GMAT t;00M CH: 9-0 MASTED I3A1H CH: S-0 RED HAWK FIRE PROTECTION, LLC COVMP PA110 CH: 9-0 CONNECT TO TOILET CI -05N CH: 8-0 KI1-CHN CH: 9-0 r3.12POOM 2 CH: 8-0 u111.-Iry CH: 6-0 I31 P OOM CH: 8-0 P OTECTED FROM ABOVE 511anY CH: 9-0 Hydraulic Information Remote Area 01 -Entry OCCUPANCY CLASSIFICATION Residential DENSITY 0.050gpm/ft2 for 900.00ft2 (Actual 211.80ft2) TOTAL HEADS FLOWING 2 K -FACTOR 4.9 TOTAL WATER REQUIRED 40.15 TOTAL PRESSURE REQUIRED 43.560 BASE of RISER (gpm) 40.15 BASE of RISER (psi) 35.754 SAFETY MARGIN (psi) +76.405 (63.7%) MINIMUM DISTANCES FOR ORDINARY- AND INTERMEDIATE -TEMPERATURE RESIDENTIAL SPRINKLERS (NFPA 13D-2002 TABLE 7.5.5.3) HEAT SOURCE MINIMUM DISTANCE FROM EDGE OF SOURCE TO ORDINARY- SPRINKLER (INCHES) MINIMUM . DISTANCE FROM EDGE OF SOURCE TO INTERMEDIATE - .. SPRINKLER (INCHES) SIDE OF OPEN OR RECESSED FIREPLACE 36 12 FRONT OF RECESSED FIREPLACE 60 36 COAL- OR WOOD BURNING STOVE 42 12 KITCHEN RANGE 18 9 WALL OVEN 18 9 HOT AIR FLUES 18 ': 9 UNINSULATED HEAT DUCTS 18 9 UNINSULATED HOT WATER PIPES 12 6 SIDE OF CEILING- OR WALL MOUNTED HOT AIR DIFFUSERS 24 12 FRONT OF WALL MOUNTED HOT AIR DIFFUSERS 36 18 HOT WATER HEATER OR FURNACE 6 3 LIGHT FIXTURE; OW -250W 6 . 3 LIGHT FIXTURE 250W -499W . , 12 6 • e 1 fe 2301 E PIONEER AVE, SUITE B PUYALLUP, WA 98372 PHONE: (253) 840-9900 FAX (800) 591-4382 WA CL# REDHAHF901QP ApprovalsRequired CITY OF TUKWILA OWNER / ARCHITECT Revisions 1 - 01.13.15 Revisions to make flow system OPEN 10 C3rLOW Caution: It is important that the insulation be installed tight against the joists; In unheated areas, any spaces or voids between the insulation and the joists' causes the water in the fire sprinkler piping to feeze. VN11 Y CH: 9-0 29815 24TH AVE SW FEDERAL WAY, WA 98023.. CONTACT: CARY LANG Phone: 206-423-5055 GAKAGk CH: 9-0 Contract Name: 13MOOM 4 CH: 6-0 COV I P PORCH CH: 9-0 PLAY?OOM CH:. 8-0 Caution: Far areas having temperatures of 0°F (-18°C) or lower, an additional batt of insulation covering the joist and the fire sprinkler piping should be used.. If this is not done, freeze -ups can occur in the sprinkler piping. 13017 56th AVENUE TUKWILA, WA 98178 Drawing Title FIRE SPRINKLER PLAN UPPER FLOOR HANGER FIG. 188 INSULATION DETAILS HANGER FIG. 185 WOOD JOIST OR COMPOSITE WOOD JOIST FIG. 126 LAG BOLT FIG. 126 LAG BOLT HANGERS - PIPE HANGERS SHALL BE SIZED, SPACED AND INSTALLED AS REQUIRED BY NFPA STANDARDS NO OTHER PIPING AND/OR DEVICES ARE TO BE ATTACHED TO THE SPRINKLER PIPE HANGER SYSTEM UNLESS THE HANGER HAS BEEN SPECIFICALLY DESIGNED FOR THE ADDITIONAL LOADING.' - THIS CONTRACT DOES NOT INCLUDE ANY MATERIAL OR DEVICES TO IMPROVE THE STRUCTURAL STRENGTH OF THE BUILDING TO ENABLE IT TO CARRY THE LOAD OF THE FIRE PROTECTION SYSTEM. SEE DETAILS ON THIS SHEET FOR THE SPECIFIC HANGER ASSEMBLIES USED FOR THIS INSTALLATION.' NFPA 13, 2010 Edition Table 9.2.2.1 MAXIMUM DISTANCE BETWEEN HANGERS (ft in) NICET Stamp WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS David Fox 0121-0409-C Level 3 Red Hawk Fire Protection, LLC REDHAWHF901 QP 05/10/16 Signature Date NOMINAL PIPE SIZE ( IN.) Date: Job Number: Designer: Building Permit:. May 09, 2016 80048 DANIEL ERNSTING Sprinkler Legend Symbol Manufacturer Response Type SIN K -Factor Size Temperature Finish Escutcheon Spacing Discharge Quantity I Globe Quick Pendent GL4906 4.9 1,4 155°F Bronze Conceald 16x16 , 13 gpm @ 7 psi 21 Globe Quick Pendent GL4910 4.9 1/2 175°F Bronze Conceald 16x16 14 gpm © 8.5 psi 1 Globe Quick Sidewall GL4231 4.2 IA 155°F Bronze Recessed 16x18 19 gpm @ 20.5 psi 1 Total = 23 Drawing No. FP 2.01