PP - 13013 56TH AVE S - ARCHER RESIDENCE - PERMITS AND PLANS
13013 56TH AVE S ASSOCIATED PERMITS 97-5-152 i" METER CITY MAIN GARAGE GOUND 111 FLOOR PIP NG PLAN UNDRGOU\D NOTES 1 UNDERGROUND SHOWN HERE FOR REFERENCE AND HYDRAULIC CALCULATIONS O LY 2 ALL UNDERGROUND SUPPLY PIPING TO BE INSTALLED IN ACCORDANCE WITH N F A #24, TUKWILA BUILDING AND WATER DEPARTMENTS STANDARDS AND SPECIFICATIO S 3 UNDERGROUND TO BE TESTED AND FLUSHED PRIOR TO THE INSTALLATION OF A AVE GROUND PIPING HANGERS, FOR C.P V.0 (PLASTIC ,PIPE MAX. HANGER SPACING ' FASIENER HEX HEAD APPROXI WEIGHT -DECK 1 OVERHEAD SPRINKLER , PIPING AND FITTINGS TO BE CPVC, INSTALLED IND TESTED PER N F P A #13D, CITY OF TU <WILA AND THE MANUFACTURERS SPECIFICATIONS 2 PIPE SIZED PER HYDRAULIC CALCULATIONS SYSTEM DESIGNED PER N F P A #130 WITH HEADS SPACED © 400 SQ FT MAX (20X20) PER MANUFACTURERS SPECIFICATIONS HEADS ARE CENTRAL ROC K=4 2, 20FT MAX BETWEEN HEADS 10FT MAX OFF WALL 3 HANGERS TO BE TOLCO FIG 23 AND 24 FOR USE W'TH CPVC PIPE (SEE DETAIL) 4 MAXIMUM DISTANCE BETWEEN HANGERS' PER CPVC MANUFACTURER HANGERS MUST BE LOCATED WITHIN 6" OF EACH DROP C ADEQUATE HEAT AND INSULATION PROVIDED BY OTHERS OWNER TO MANTAIN HEAT AND INSULATION TO PREVENTFREEZING DF WET PIPE SPRINKLER SYSTEM N ALL CASES INSULATION MUST BE PLACED SO THE HEAT FROM INSIDE THE UNITS CAN REACH THE WET PPE INSULATE ONLY ABOVE PIPE IN ATTIC, OUTSIDE ONLY OF PIPE EXTERIOR WALLS 7 ALL AREAS INSIDE UNITS TO HAVE SPRINKLERS EXCEPTIONS AS NOTED, PER N F P A #13D SECTION 4-6, A) SPRINKLERS ARE NOT REQUIRED IN BATHROOMS 55 SQw FT4 AND LESS B) SPRINKLERS ARE NOT REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES WHERE THE AREA OF THE SPACE DOES NOT EXCEED 24 SQ FT AND THE' LEAST DIMENSION DOES NOT EXCEED 3 FT, AND WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED COMBUSTIBLE MATERIALS AS DEFDINED IN NEPA 220, STANDARDS 'OF BUILDING rl CONSTRUCTION C) SPRINKLERS MAY DE OMITTED FROM GARAGES, OPEN ATTACHED, PORCHES, CARPORTS, AND SIMILAR STRUCTURES t C 0) SPRINKLERS MAY BE OMITTED FROM ATTICS, CRAWL, SPACES, AND OTHER CONCEALED SPACE'S I+ THAT ARE NOT USED OR INTENDED FOR LIVING PURPOSES OR STORAGR MAt \ FLOOR PIPING PLAN 1 , DRAIN VA & INSP TEST WATER PRESSURE GAUGE WATER FLOW IND PIPE STAND 1 BACKFLOW PREVENTOR r 'RISER DETAIL COPPER TIE-IN TO DOMESTIC WATER FUTURE LIVING SPACE ATTIC SPACE PIP r1 ISG PLAN UkwILA PIAE CEPA RTM4t Please call 575 444 t nd give this job I to ind ddress down estorabono r shut' donapproval. TYP 2X FRAMING ACCEPTED Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by 'R Tukwila Fire Prevention Bureau for conformance withcurrent city this date will resubmittal o Final accept The Tukwila Data d his acceptance and will require a vvised drawings for subsequent approval • nce is subject to field test and inspection by re Prevention ureau 11)1m@giwr CRbSS SECTION r f11 -x• JUN 1 8 1997 SAF 1111ORG: ACH,ER 13013 56TH A'VE' TUKWILA, WA 4, THE SAFETY TEAM,, 1NC 670 SOUTH LUCILE STREET P 0, BOX 81246 SE:ATTLE,, WA 98108 SCALE 1/4" 0 DATE 6-10-97 re - JOB v IV