HomeMy WebLinkAboutPP - 576 INDUSTRY DR - FIDELIS COMMUNICATIONS INC. - PERMITS AND PLANS576 INDUSTRY DR ASSOCIATED PERMITS 14-F-142 93-F-308 MUM SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: 576 Industry Drive Tenant Name: Fidelis Communications New Tenant? -Yes ❑ El- No Property Owner's Name: Andover Executive Park Mailing Address: POB 130940, Carlsbad, CA 92013 CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 206.349.5889 Company Name: Guardian Security Systems Mailing Address: 1743 First Ave South, Seattle, WA 98134 kveliz@guardiansecurity.com City State Zip E-mail Address: Fax Number: 206.628.4990 Total number of new/relocated devices or sprinkler heads: 34 Valuation of Project (contractor's bid price): $ 5000. Scope of Work (please provide detailed information): Adding -devices to existing IFACP. King Co. Assessor's Tax No.: 0223400010 Suite Number: Floor: City State Zip PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 ER O$ AUTHORI D GENT: f n -12) � Signature: W' Date: AJC, Print Name: Karina Veliz Day Telephone: 206.349.5889 Plan Permit App.doc 1/2/13 TFD FP Form 8 16' ACCEPTED &WITHOUT COM C; N.TS.j 350 f ❑ AS NOTED IN R•=J) ❑ PER THE ATTAC - ED LETTER The drawings affixed heretd re$ 'ii reviewed and accepte.1 by tI y oI. Tukwila Fire De it. A :! 1i+i or revisions to this, r i ;; aft v this date will void thi.; n I hill require a resubrlitt,J re.i� 1r. wings. Final acceptance is subject to field - inspection by a representative of this department DATE: ! if 7 53 ,BY:,_...101 S/t CITY OF TUKWILA 575-4407 CtASE T 5 7 5 .L n1WAST2Y fl2 TUKWILA FIRE DEPARTMENT. Please call: 575.4407 and give this job No. ;SB 4 and exact address for shut- down or restoration approval. TE OP: RISC 14E -A -r 6Cr�..CTisP.... CYfSrNG HEA -r bETF:C.Tmftl, .ZNS1g., no 1993 C.�i3�ts FIDELIS COMMUNICATIONS FIRE ALARM SYSTEM ADDITION TUKWILA, WASHINGTON SHEET # DESCIPTIO\ FA -01 SHEET INDEX, SY v130L LIST,. WIRE DESIGNATIONS AND CALCULATIONS FA -02 TYPICAL WRING AND MOUNTING DETAILS FA -03 FI RE ALAR \1 PLAN AND NAC SINGLE LINE DIAGRAv HEET INDEX QUANTITY EX 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM CONTROL PANEL (EXISTING) D9112 BOSCH EXISTING VERIFY IN FIELD BPS REMOTE BOOSTER POWER SUPPLY (NEW) PAD -3 SIEMENS PAD-3—ENCL 66" A.F.F. TO TOP SMOKE DETECTOR 17 ® PHOTOELECTRIC (NEW) EX 1 EX EX 10 5 E 2W—B SYSTEM SENSOR 4—INCH OCTAGONAL BOX CEILING OSA ABOVE CEILING SMOKE DETECTOR (EXISTING) EXISTING EXISTING EXISTING ABOVE CEILING HEAT DETECTOR (NEW) 5601 P SYSTEM SENSOR 4—INCH OCTAGONAL BOX CEILING HEAT DETECTOR (EXISTING) EXISTING EXISTING EXISTING CEILING MANUAL PULL STATION (EXISTING) EXISTING EXISTING EXISTING 48" A.F.F. TO CENTER 8 FIRE ALARM HORN STROBE (NEW) ZH—MC—CW SIEMENS 4S BOX CEILING FIRE ALARM STROBE (NEW) ZR—MC—CW SIEMENS 4S BOX CEILING PIEZOELECTRIC V TRANSDUCER (EXISTING) EXISTING EXISTING EXISTING VERIFY ON FIELD END—OF—LINE RESISTOR N/A N/A N/A N/A EX EXISTING DEVICE/ EQUIPMENT N/A N/A N/A N/A A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EOL END OF LINE RESISTOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A WIRE DESIGNATION FIRE ALARM BOOSTER POWER SUPPLY BATTERY CALCULATION I Project:; FIDELIS COMMUNICATIONS Panel ; PAD -3 BOOSTER POWER SUPPLY (ELECTRICAL ROOM) Date: ;June 23, 2014 Module/Device Qty Standby Total Standby Alarm Total Alarm (mA) (mA) (mA) (mA) Power Module 1 ATOTAL FIRE ALARM POWER SUPPLY 30 30 0 30 30 30 0 30 B Auxiliary Device Current 0 0 C = Notification Appliance Load (Max. Total / mA) 0 1479 Total(A) CALCULATION D Total current ratings of all devices in system (line A + line B + line C) 30 Total(B)= 1509 30 1509 E Total current ratings converted to amperes (line D x .001) 0.03 1.509 F Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 G Multiply lines E and F Total Standby AH 0.72 H Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 I Multiply lines E and H Total Alarm AH 0.1256997 J Add lines G and I Total Standby and Alarm AH 0.8456997 K Multiply line J by 1.2 (20% extra insurance to meet desired performance) 1.01483964 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 Notification Appliance Circuit Detail PROJECT: FIDELIS COMMUNICATIONS PAD -3 BOOSTER POWER SUPPLY (ELECTRICAL RM) ;Wire Resistance 2.58 June 23, 2014 CURRENT TOTAL=1 1479.00 ZR -MC -W @15cd TOTAL mA= CALCULATIONS 4 WISE SCHEDULE A\D CONDUIT FILL CHAT O Without Comments 0 As Noted in Red O Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances, The responsibility for the adequacy of des4p ;,:, s totally with the designer, Additions, deietiony, 5 4. s-evisions to these drawing; after tris date will void this acceptance and will requira a resubmittal of revised drawings for subsequent approval, Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: -.Z-r `( By: VIM s `( C11 JuK. rek.of-e L .e.0 's 6t' 0,444. . oiSwe 64,+1 . eNvt4- byredAtt- il4hdl-e etA H.� o►, a�c��� 1 c vc-.: NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing TUKWILA FIRE DEPARTMENT Nene call 206-575-4407 and give this Fire Permit No. :ld exact address for sliut- ;d wn or restor on approval. WIRE DESIGNATION PAD ,JUN ;?3 7It1la i.,U"q lLA FIR cc /-7.6' Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved co z 0 z_ LLJ w cn0 (1) 1,0 Lv FAX (206) 628-4990 TEL. (206) 622-6545 z 0 U) w w U) LU J LU REV. BY: D M G WIRE DESIGNATION SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE I S INITIATION CIRCUIT TWO #16 FPLP SIGNALING CIRCUIT TWO #14 FPLP DESCRIPTION 0� Z CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. O Without Comments 0 As Noted in Red O Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances, The responsibility for the adequacy of des4p ;,:, s totally with the designer, Additions, deietiony, 5 4. s-evisions to these drawing; after tris date will void this acceptance and will requira a resubmittal of revised drawings for subsequent approval, Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: -.Z-r `( By: VIM s `( C11 JuK. rek.of-e L .e.0 's 6t' 0,444. . oiSwe 64,+1 . eNvt4- byredAtt- il4hdl-e etA H.� o►, a�c��� 1 c vc-.: NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing TUKWILA FIRE DEPARTMENT Nene call 206-575-4407 and give this Fire Permit No. :ld exact address for sliut- ;d wn or restor on approval. WIRE DESIGNATION PAD ,JUN ;?3 7It1la i.,U"q lLA FIR cc /-7.6' Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved co z 0 z_ LLJ w cn0 (1) 1,0 Lv FAX (206) 628-4990 TEL. (206) 622-6545 z 0 U) w w U) LU J LU REV. BY: D M G DESCRIPTION 0� Z 4 0 1 0 I V) DATE a :c., 0 2a<aaa N �CALE: 1/4"=1'0" DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 06/20/14 BACKROUND PLAN PROVIDED BY: 1.0B NUMBER: SHEET FA -0 1 JUNCTI❑N BOX MOUNTED ON CEILING FLEX / / / / / / / 0 0 0 0 4S BOX W/ 1 MOUNTED AGA CEILING SUPF TO NEXT DEVICE G MUD RING INST ORT SMOKE/HEAT DETECTOR SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUNTING DETAIL TRIGGER FROM EXISTING BOSCH CONTROL PANEL 0 GND N AC TB1 0 0 11,d0 0 0 00 PAD -3 POWER SUPPLY (ELECTRICAL ROOM) 0 INPUT INPUT TROUBLE NAC1 NAC2 NAC3 NAC4 AUX 1 + 1- 1 2+ 2- 2 NC C NO + - + - + - + - + - 0 0 0 0 0 3.6k EOL 0 0 0 0 0 0 0 0 0 0 0 PAD-3POWER SUPPLY WIRING DETAIL TB2 n__ S HARD LID CEILING SPARE SPARE NAC CKT S2 NAC CKT S1 CADDY BAR 4" SQUARE DEEP BOX 7 WITH 1 -GANG RING CEILING STROBE OR HORN STROBE HORN/STROBE & STROBE MOUNTING DETAIL (DROP CEILING) TO PAD -3 POWER SUPPLY HARD ;LID CEILIING HORN STROBE TYPICAL WIRING AND MOUNTING DETAILS STROBE SUPPORT BRIDGE 4N SQUARE DEEP BOX CEILING STROBE OR HORN STROBE HORN/STROBE & STROBE MOUNTING DETAIL (HARD LID) HORN STROBE TYPICAL NAC CIRCUIT WIRING DETAIL STROBE HORN STROBE EOL Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved '4 CC 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 U) z 0 U) w w U) a w J W REV. BY: 0 2 0 DESCRIPTION 0 Z 4 0 L 0 I DATE 0 0 N lD 0 2<<aaa CD Zne F- 0o0o z DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 06/20/14 BACKROUND PLAN PROVIDED BY: s0B NUMBER: i SHEET FA -022 1E. EXIST 1 \, C)US TO NEW SIEMENS PAD -3 BOOSTER POWER IN ELECTRICAL ROOM t��......X ...)I II,��.� tAN,k ..I } 01.I ~I...... TO NEW SIEMENS PAD -3 BOOSTER POWER IN ELECTRICAL ROOM E) o -S \ EW (:)3[::::..N OFF S2-1 15Cd o—S l`. r`\F\ E C.. i,; OUSE S1-1 15Cd '1A NV .............I [1 N. S2-8 Lao1Cd r- S2-7 .30Cd 0 D _1\ _4N of FIC EIDE. , S2; \-,d ,„ U,� ' b yep EXL)TI \ PREAKR0 ) v1 )-) CPT cD—S isk STING VV .)[\ <RC.) ..)M / (N) l S2-2 30Cd Ci V S1-2 0 30Cd SHOWER _--5.5__ 15Cd _, EX STING OFFICE S1-3 15Cd o -S 1J/ (L) S2-5 15Cd f �E.1f�� r 21—c 21 OFF 0 DOOR- 3E LOC,[ LD O I.T. S2-4 \/c"1 _ 7 EXISTING (?F Lhi nF s 1-6 30Cd ri S1-7 15Cd :r- 0 F-( I c N - W C, ... I... c 1 PROVO ROVI FO 1UIF._)I\J 3IANDARF) i M 1 N 31...1NDS EW STOR.EF.. `.: Y s --1 _. [ _:: _ M \J j CONFER. r I1 EQL { FLAGNOTES: EXISTING HEAT DETECTOR TO BE REPLACE WITH NEW SYSTEM SENSOR 2WB SMOKE DETECTOR. EXISTING HEAT DETECTOR TO BE REMOVE. EXISTING PIEZOELECTRIC DEVICE TO BE REMOVE. EXISTING MANUAL PULL STATION TO BE REMOVE. S2-1 S2-2 S2-3 S2-4 S2-5 S2-6 S2-7 S2-8 15Cd 30Cd 15Cd 15Cd 15Cd 15Cd 30Cd 30Cd FACP FH BPS S1-1 30Cd (ELECTRICAL ROOM) S1-2 30Cd 15Cd 15Cd 15Cd 30Cd 15Cd S1-3 S1-4 S1-5 S1-6 S1-7 ) 120 VAC, DEDICATED ( BY OTHERS ) NAC SINGLE LINE DIAGRAM SCALE: NONE EOL S1 Copyright 2014 by Guardian Security Systems, Inc. All Rights Reserved EOL S2 r 1743 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 z 0 w w 0) a w J W (REV. BY: ' 0 2 0 DESCRIPTION 0 z 4 Ct 0 0.0 I DATE 0 0 <aaa DRAWN BY: D. GARCIA DESIGNED BY: R. VEZZANI DATE: 06/20/14 BACKROUND PLAN PROVIDED BY: \0B NUMBER: i SHEET \ FA -03 J