HomeMy WebLinkAboutPP - 610 INDUSTRY DR - ENTERPRISE MERCHANT SLUTION - PERMITS AND PLANS610 INDUSTRY DR
ASSOCIATED PERMITS
08-F-491 888127
TUKWILA FIRE DEPARTMENT
Please call: 575-4407
and givethis job
No. R R R 12'
and exact address for shut•
down or restoration, approval.
ACCEPTED
COMMENTS.
tWITHOUT
NOTED IN RED LETTER
PER THE ATTACHED L
The drawings affixed hereto have been
reviewed and accepted by the City of
Tukwila Fire Dept. Aiditions, deletions
or revisions to these Jr=+wings after this
date will void this accc() }tince and will
require a resubmittal of revised drawings.
Final acceptance byy a representative of this
department
r � �
DATE:
CITY OF TUKWILA
575.4407
•
--------- --
p error►
eP
D4 606 608 610
A
B
C
D
1
2
3
4
5
6
7
8
9
10
E
F
G
H
FIRE ALARM WIRE LEGEND
DESIG.
DESCRIPTION
A
16/2 FPLR INITIATING CIRCUIT WIRING
B
14/2 FPLR INDICATING CIRCUIT WIRING
C
16/4 FPLR ANNUNCIATOR CIRCUIT WIRING
D
14/2 FPLP DUCT DETECTOR OR DOOR HOLDER POWER WIRING
E
AWG-16-THHW FOR DIRECT BURY/WET LOCATION
KEY LEGEND COMPONENT LIST
SYMBOL
DESCRIPTION
QTY
PART #
MANUFACTOR
MOUNTING SPEC
I FACP I
FIRE ALARM CONTROL PANEL
1
5808
SILENT KNIGHT
WALL TOP @ 66"
I FSE I
FIRE SIGNAL EXPANDER
WALL TOP @ 66"
ANN I
ANNUNCIATOR
1
5860R
SILENT KNIGHT
WALL TOP @ 66"
I TRAN I
TRANSMITTER
FIELD VERIFY
I STU I
SUBSCRIBER TERMINAL UNIT
FIELD VERIFY
IEl
HORN
WALL @ 80"-96"
0.111
MINI -HORN
WALL @ 80"-96"
CEI
BELL
1
MB -G10 -24R
WHEELOCK
OUTSIDE WALL @ 10'
BELL -STROBE
WEATHER PROOF ON WALL @ 10'
g
STROBE
4 / 1
ZRS-MCW-FR / RSSWP
WHEELOCK
WALL @ 80"-96"
I/4 j
HORN -STROBE
1
ZNS-MCW-FR
WHEELOCK
WALL @ 80"-96"
aN
CEILING MOUNTED HORN/STROBE
3
ZNS-MCC-FR
WHEELOCK
CEILING
aCEILING
MOUNTED STROBE
3
ZRS-MCC-FR
WHEELOCK
CEILING
C
CHIME
FIELD VERIFY
Qs
SPEAKER
WALL @ 9o"
OJ
JUNCTION BOX
FIELD VERIFY
DOOR HOLDER
FIELD VERIFY
DH
DOOR STRIKE
FIELD VERIFY
DS
F
MANUAL PULL STATION
1
MS -701 U
MIRCOM
WALL @ 48"
® AB
SMOKE DETECTOR ABOVE CEILING
ABOVE CEILING OR IN DUCT
®
SMOKE DETECTOR
16
2WB
SYSTEM SENSOR
CEILING - 3' FROM AIR DEFUSER
® BL
SMOKE DETECTOR BELOW FLOOR
BELOW FLOOR
®
135° FIXED TEMP HEAT DETECTOR
CEILING
1941®R
194° RATE OF RISE HEAT DETECTOR
CEILING
®R
135° RATE OF RISE HEAT DETECTOR
CEILING
194°®
194° FIXED TEMP HEAT DETECTOR
CEILING
LINE TYPE HEAT DETECTOR
FIELD VERIFY
WATERFLOW SWITCH
RISER PIPE
WF
PRESSURE SWITCH
RISER PIPE
PS
I 'sI
TAMPER SWITCH
GATE VALVE
JB
JUNCTION BOX ALONGSIDE DEVICE
FIELD VERIFY
M
MONITOR MODULE
7
SD500-MIM
SILENT KNIGHT
FIELD VERIFY
ADDRESSABLE RELAY
FIELD VERIFY
R
REMOTE
ANNUNCIATOR
TO CENTRAD
STATION
MODEL 586DR
•
FACP
#16/4
PHONE LINE #1
PHONE LINE #2
120 VAC S
(DEDICATED CIR.)
12,[7]
0
Silent Knight
5808
4��
Duu
DIALER
SILENT
KNIGHT
33:001 33:002 33:003
NAC -1
#16/2
ZONE 1
co
to
ZONE 2
0
co
u.i
U)
J
K
L
M
Calculate
BUILDING 8
90904
NELS
10/6/2008
Addrsbl SLC Devices
LCD Remote Annunc
Serial/Parallel Module
Power Expander
LED Annunciator (4G)
LED Annunciator (3G)
LED Driver Module
Other
DC Duct Hsg w/Relay
Relay Module
1 Notification Appl Circuit
i ... ic tis
Notification Appl Circuit
Notification Appl Circuit
Notification Appl Circuit
*1 # of NAC's Used
ndf#ytwurrent(Ig
Tot l
11
0000
0.000
0:000
0000:
0 450
0.7931'
o.000 0:168::
0:000 0.000
0.000 0 000
0,229
14 Solid
14 Solid
#14 Solid
#14 Solid
1.912 Tt
tlAlarnt Gurreht: Al
Al r t TIMO
600
450
175
VAT
33:004 33:005
ZONE 3
co
ui
U)
BELL
OD EXISTING QTY 15 TOTAL OF 450mA
030mA
75cd 75cd 15cd 75cd 75cd
184mA 082mA 065mA 065mA 082mA
NAC -3
NAC -4
75cd BELL
ED EOL
138mA 030mA
117-1 .r,.
, #14/2
BATTERY BATTERY
12V -7A11 12V-7AR
RISER DIAGRAM
SPARE
ZONE 4
0
Co
st
0
cncn
15cd
Multinlif 8j The DeratlnO Factor
Mlriltlttlm taiteryArnoHo tr Reg3
33:006
33:007
ZONE 5
0
co
cn
15cd
ZONE 6
ce
cc
0
U
15cd
ZONE 7
W
z
Command Shortcuts
;;`6.67%
8;7.1%;
073%
0.00%
75cd 75cd75cd
® a EOL
060mA 060mA 060mA 060mA 065mA 082mA
Notification Appl Circuit
Unused
Unused
Unused
as
Totals
000a
(t
0:450_ ;
Notification Appl Circuit
ZNS-MCW-FR 75cd
2
ZNS•MCC-FR 75cd
3
ZRS-MCC-FR 75cd
4
ZRS-MCW-FR 15cd
is
01,1
-§
...'.lJl:`Yj
Totals
58€18
Notification Appl Circuit
0.000
OUrfBrit w Total' '
MB -G10 & RSSP
Unused
Unused
Unused
1g;
Totals
BLDG. 8 STE. 610 INITIATING PLAN
1/8"=1'-0"
0.000
0;168
TONAC CKT.#2 —
75cd
N
WAREHOUSE
MAP OF LOCATION
WKWILA FINE DEPARTMiE»N1
Please call: 575-4407
and give this job
No. 0y-F-`lct1
y
and exact address for shutTh,d
Jowin or restoratiah aDorove,
STOCK ROOM
STORAGE
STORAGE
rot
OFFICE
OFFICE
OFFICE
15cd
p
B
15cd
CONFRENCE
P 321 15cd
B
OFFICES
KITCHEN
R.R
EOL
15cd
R.R.
15cd
OFFICES
15cd
R.
15cd
J
E
LOBBY
II
E
15cd
CONFRENCE
TO NAC CKT.# 3
UP
F.,us
1! WithaUt CbxJ 0*n*
E' As Noted In Red
n Per The Attached letter
I hese plans have been reviewed by The Tukwila Fire
Prevention Bureau for conformance with current city
standards. Acceptance is subject to errors and
omissions which do not authorize violations of adopted
standards and ordinances. The rE:i ponsibitity for the
adequacy of design rests totally with the designer.
Additions, deletions or revisions to these drawings atter
this date will void this acceptance and will require a
4 resubmittal of revised drawings for subsequent approval.
Final acceptance is subject to field test and inspection bti
The 'Tukwila Fire Prevention Bureau.
Date: .1 ° "'Z � —o � By: S"1 l
i.4cc.mek�nnmm�rR�.aH-F J
h) -i-a t l 10 Ger -oL)4 oo&e circ, L.t J
�rc4.t..+..
NOTICE
A completed, signed, Tukwila
Fire -Department Pre-test
Certificate must be presented
to the Inspector prior to
commencement of Acceptance
Testing of any Fire Alarm
and Detection Systems.
Failure of test will result
in a Re -inspection Fee and
termination of the testing.
IMPORTANT NOTICE
Because of increased demand our
inspectors' schedules are booked
3-7 days ahead. Therefore, you
will need to call 206-575-4407 to
schedule your inspections a
minimum of 48 hours in advance
of the date you want an
inspection.
'tt, )ij ig jEtwLA eke. -
BLDG. 8 STE. 610 - NOTIFICATION PLAN
1/8"=1'-0"
GENERAL NOTES:
1. EXISTING HEAT DETECTORS ABOVE THE CEILING.
2. (E) - IS AN EXISTING DEVICE TO REMAIN UNCHANGED.
3. DEDICATED FIRE ALARM SYSTEM CIRCUIT SHALL BE EQUIPPED WITH LOCKOUT DEVICES.
4. CONTROL PANEL RESET CODE SHALL BE 1-2-3-4-5
ISSUED FOR APPROVAL
b
m
O
Z
0
LTJ
ELECT. FIREOI*099KW
206-575-0311
107 WASHINGTON BLVD. ALGONA WA, 98001
REIT MANAGMENT BLDG. 8
610 INDUSTRY DRIVE STE. 610
ILA, WA 98188
D
I—
¢z
0
CC
Ir
LU
CC
W LL
C
LL-
0
CO
Lis
Lr
APPROVED BY :
ER
DRAWN BY:
RG
DATE:
10-6-08
JOB#
90904
DWG. NO. :
FA -01 )