Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 617 INDUSTRY DR - APPLIED RESTORATION INC. - PERMITS AND PLANS
617 INDUSTRY DR ASSOCIATED PERMITS 15-F-205 00-F-052 95-F-226 OS -F-255 96-F-121 888-074 Viattk sir /., SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 617 Industry DR Bldg 9, Tukwila, WA 98168 Suite Number: Floor: Tenant Name: Andover Executive PK Bldg 9 New Tenant? ❑ - Yes - No Property Owner's Name: NCWP Andover Executive Park Mailing Address: same as site address CONTACT PERSON -if there are questions about the submittal. Name: Karina Veliz Day Telephone: 206.349.5889 Company Name: Guardian Security Systems Mailing Address: 1743 First Ave South, Seattle, WA 98134 kveliz@guardiansecurity.com City State Zip E-mail Address: Fax Number: 206.374.2852 0223400045 City State Zip Total number of new/relocated devices or sprinkler heads: 9 Valuation of Project (contractor's bid price): $ 3,800' Scope of Work (please provide detailed information): Add 9 devices to existing FACP. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING I ' AUT O '; ED AGENT: \ I Signature: - Date: Print Name: arina Veliz Day Telephone: 206.349.5889 Plan Permit App.doc 1/2/13 TFD FP Form 8 • vog14 Tb 15'. P Fo cet ACCEPTED WITHOUT COMMENTS. • ❑ AS NOTED IN RED ❑ PER THE A ACHED The drawings reviewed and ac Tukwila Fire De or revisions to t,� date will void this require a resubmittal fixed hereto•.. - •ted by the city of • itions, •de,. etions r�ca awrsr ins$ait i5 acceptance and IdM f revised drawings. Final acceptance is s tbject to field - inspection by a representative of this department DATE: y 1'l# BY: CITY OF T JKWILA 07 &,sriN' leAdt eitf ,E m,C. As. /1 Auk 577/Lwow MINIM 111=MIIMP VMS= 011=11. .1••111 £0 TUKWILA GYM���,..,-,» 4 .;„path! 7e .1. ANDOVER EXECUTIVE PARK FIRE ALARM SYSTEM ADDITION -BUILDING 9 TUKWILA, WASHINGTON SHEET # FA -01 DESCIPTIO\ SHEET INDEX, SYMBOL LIST, WIRE DESIGNATIONS, CALCULATIONS AND FLOO FIRE ALARM PLAN SHEET INDEX QUANTITY SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FIRE ALARM CONTROL PANEL EX (EXISTING) EXISTING EXISTING EXISTING REMOTE BOOSTER PAD -4-6A SIEMENS POWER SUPPLY SMOKE DETECTOR 2W—B SYSTEM (CONVENTIONAL) SENSOR ZR—MC—CW SIEMENS FIRE ALARM ZH—MC—CW SIEMENS HORN STROBE (EXISTING) El EX MANUAL PULL STATION EXISTING EXISTING EXISTING DEVICE VERIFY IN FIELD PAD-4—ENCL 66" A.F.F. TO TOP 4—INCH OCTAGONAL BOX. CEILING CEILING CEILING EXISTING CEILING EXISTING 48" A.F.F. TO CENTER 0 48 / :00%,/,,A4 **; 0.4*•#,)4,141 se ;„T ,,,k. 1 i , „A •,* • ., ,,,,,* .4* 46.,,,4* "4. ...il: 4.,,,, 4.,,,t,4„:„.,,,..., #10,„, , , , .. 7 -.4 k 1 i # 144"4. 1 1 1 • v," \, 1\ #44 04.4*, 84 lot * • 4, .. 4 le A Nil I/ A, MO, r# 404riff* N44 0 * 10 .44* issfp•• 4 • "44 Sp r 41: 4:4440At, !,11, ‘s4441g . 4,41. ®Ex HEAT DETECTOR EXISTING EXISTING 0 it,',.,,iorr4"141..i• 0•1101 , It* ill DOM DOM "4-40,ilin DOM DOM S1-5 15Cd OFFICE s6 0 0 0 a D ®Ex WAREHOUSE ABOVE FINISHED FLOOR END OF LINE RESISTOR FURNISHED BY OTHERS I = INITIATION CIRCUIT = #16/2C FPLP WIRES S = SIGNALING CIRCUIT = #14/2C FPLP WIRES SYMBOLS LEGEND *# •10; 1. ALL EQUIPMENT SHALL BE U.L. LISTED 2. ACCESS PANELS TO AREAS THAT REQUIRE SERVICING, TROUBLESHOOTING ETC. PROVIDED BY OTHERS DO NOT DEVIATE FROM CONDUIT RUNS AS SHOWN ON FLOOR PLANS WITHOUT PRIOR APPROVAL FROM SYSTEM SUPPLIER (GUARDIAN SECURITY SYSTEMS, INC. TEL. 206-622-6545). FACTORS SUCH AS EXCESSIVE VOLTAGE DROP, ADDITIONAL PARTS, ENGINEERING, ETC. THAT ARE A RESULT OF CONDUIT RUN DEVIATIONS SHALL BE THE SOLE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. 3. 4. DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIRFLOW, NOR CLOSER THAN 3'-0" (900mm) FROM AN AIR SUPPLY DIFFUSER. 5. ALL 120VAC POWER REQUIREMENTS FOR THE FIRE ALARM SYSTEM SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR AND SHALL MEET ALL REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 6. ALL FIRE ALARM DEVICE BACK BOXES, FIRE ALARM TERMINAL CABINETS, GUTTERS, JUNCTION BOXES AND ASSOCIATED CONDUITS SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. REFER TO FIRE ALARM SYMBOL LIST AND/OR MOUNTING DETAILS FOR ADDITIONAL INFORMATION. SYSTEM SUPPLIER PROVIDED BACK BOXES SHALL BE INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. 7. DETECTOR TESTING SHALL BE ACCOMPLISHED PER THE MANUFACTURER'S INSTRUCTIONS. 8. ALL WIRING SHALL BE CUT FOR IN AND OUT. WIRING SHALL NOT BE LOOPED THROUGH DEVICES. ALL SPLICED WIRE POSSESSING SHIELDS SHALL HAVE SHIELDS SPLICED AND TAPPED TO TAPED TO PREVENT GROUND FAULTS. 9. THE ALARM SYSTEM SHALL HAVE AN AUDIBILITY OF NOT LESS THAN 15dB ABOVE AMBIENT NOISE LEVELS. TESTING SHALL BE ACCOMPLISHED WITH A dB METER. 10. INSTALLATION SHALL BE IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE, NEC AND CONTRACT DRAWINGS. 11. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ. 12. A SET OF INSTALLATION AS—BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY G.S.S. FIELD TECHNICIANS. NORTH • FIRE ALARM BOOSTER POWER SUPPLY BATTERY CALCULATION Project ;TUKWILA GYM T I ANDOVER EXECUTIVE PARK BLDG. 9 Panel: (SIEMENS PAD4-9A BOOSTER POWER SUPPLY Date: November 30, 2015 Module/Device Qty Standby Total Standby Alarm (mA)(mA)(mA) Total Alarm (mA) .__. Power Module 1 60 60 0 60 60 0 A.TOTAL FIRE ALARM POWER SUPPLY 601 60 B Auxiliary Device Current 0 0 C Notification Appliance Load (Max. Total / mA) 0 808 E F G H J K Total(A) CALCULATION Total current ratings of all devices in system (line A + line B + line C) 60 868 Total current ratings converted to amperes (line D x .001) 0.06 0.868 Number of standby hours (24 or 60 per NFPA 72, Chapter 1, 1-5.2.5). 24 Multiply lines E and F Total Standby AH 1.44 Alarm sounding period in hours (5 mins+ .0833 hours) 0.0833 Multiply lines E and H Total Alarm AH 0.C723044 Add lines G and I Total Standby and Alarm AH 1.5123044 Multiply line J by 1.2 (20% extra insurance to meet desired performance) 1.81476528 12-V DC BATTERY SIZE RECOMMENDED (AMPERE -HOUR) 7 FIRE ALARM PLAN SCALE: 1/8" = 1'0" Notification Appliance Circuit Detail PROJECT: TUKWILA GYM T I -ANDOVER EXECUTIVE PARK BLDG. 9 Panel : PAD4-9A POWER SUPPLY wire Resistance 2.58 Date: November 30, 2015 CURRENT TOTAL= 808.00 itAtkielk AAA ZH-MC-CW @15cd \961.ittettlita. .40 C1 Without Comments As Noted in ted Per The Attached Letter GNOTE: CE EXIST NG HEAT DETECTOR WITH ONVENTI a NAL SMOKE DETECTOR. These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Accept nce is subject to errors and omissions which do not authorize violations of adopted ndards and orcin .aces, The responsibility for the ;).1equacy of design r =t: totally with the designer. • Additions, deIeti{ m-evislons to these drawings after this date will vo':d t.:W acceptance and will require a resubmittal drawings for subsequent approval. Final acceptance is subject to field test and Inspection by The Tukwila Fire Prevent on Bureau. TUKWILA FIRE DEPAR Amex call 206-5754407 and •yi°V ails Fre Pexmit No mc'i' xr'idmi :f 0wr I or rie; `orzal t approval, �Nst,t,Q- P S •col ated,corte.1 C cvit um -k, do, 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 V) z 0 U) w w t1J J w REV. BY: SMG I DESCRIPTION 0 z 4 0 ti 0 I DATE W IN co W CO � o >oo [to xco OZ 'o w z w o CC z oa OwLc/FE') u) 611 E11 - PAI OL1 -7 2015 �~ J TUKWILA EIRE CG2pD PAD4-6A POWER SUPPLY HORN STROBE STROBE HORN STROBE EOL Z d "CALE: AS NOTED DRAWN BY: D. GARCIA DESIGNED BY: F. PETRASKI DATE: 11/25/15 BACKROUND PLAN PROVIDED BY: GENERAL NOTES CALCULATIONS TYPICAL WIRING DETAIL Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved .JOB NUMBER: 14536—J ,\It SHEET FA -01 SHEET # E ALARM SYSTEM ADDITION -BUILDING 3 TUKWILA, WA DESCIPTIO\ FA -01 SHEET INDEX, SYMBOL LIST, WIRE DESIGNATIONS, AND PARTIAL FIRE ALARM PLAN SHEET INDEX QUANTITY 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM CONTROL PANEL EX (EXISTING) 8112 RADIONICS EXISTING VERIFY IN FIELD PS AUXILIARY POWER SUPPLY PS -12/24-8 WHEELOCK PROVIDED 66" A.F.F. TO TOP 10 ® SMOKE DETECTOR (CONVENTIONAL) 5 4W— B SYSTEM SENSOR 4S BOX CEILING ® HEAT DETECTOR EX (EXISTING) EXISTING EXISTING EXISTING CEILING 04 FIRE ALARM HORN STROBE AS-24MCC WHEELOCK —FW 4" SQUARE DEEP BOX CEILING Yt,{ FIRE ALARM STROBE RSS-24MCC WHEELOCK —FW 4" SQUARE DEEP BOX CEILING EX EXISTING DEVICE N/A N/A N/A N/A ABOVE FINISHED FLOOR N/A N/A N/A N/A EOL END OF LINE RESIST❑R N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A SYMBOLS LEGEND WISE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N 2 0 SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE I INITIATI❑N LOOP TWO #18 FPL/FPLR P DEVICE POWER TWO #16 FPL/FPLR S SIGNALING CIRCUIT TWO #16 FPL/FPLR RED (JACKET) RED (JACKET) RED (JACKET) CONDUIT FILL CHART SUBMITTED FOR APPROVAL NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 O.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 O.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 O.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. TO EXISTING INITIATION LOOP C TO EXISTING SIGANLING CIRCUIT 2 TO CONTROL PANEL (NEW POWER WIRE) 2 0 (-)[ NOTE CONTROL PANEL NEEDS KEYPAD 1252 AND 136 RELAY. TUKWILA FIRE DEPARTMEN Please call: 575.4402 .-- and give this job Nb. 0 3 -F - 0 1 WAREHOUSE c>.3> :r EX EX y, I I S tom,.1<-k d e -i eA)-\ 120 V. BY OTHEI S LPN w S1�1 15cd -==i I,P—o `L EOL S -- 1 ENOL 15cd -LP kJ \ ROLLING r; r� L; S BElNCH -(6i SALES e, El— :I ISP S—c) S 1& 15cd I,P S"vv `-'HE M (3) F- I l__. E. 03; I? o ' S1-3 15cd I,P 1 04 •_t1 -5- S1-6 15cd S1-7 I 75�d1 E9_ COI`FEREi1 El NORTH Al ARM Fl 4\ SCALE: cc: Without Comments As Noted In Red Par The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this,acceptanee and will require a esubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and Inspection by. The Tukwila Fire Prevention Bureau. td exact address for shut.) ,wn or restoration aoorouali, 1/8" = 110" NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alar, and Detection System Failure of test will resu it' in a Re -inspection Fee an termination of the testtin.. KEY PLAN C7: y o. 1,0 CO CT 1743 1ST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: 2 0 DESCRIPTION SUBMITTED FOR APPROVAL W F— 0 O N z CCCCC SALE: LU (I) >IN (/) AS NOTED DRAWN BY: D.GARCIA DESIGNED BY: F.CLOSE DATE: 12/21/05 BACKROUND PLAN PROVIDED BY: `JOB NUMBER: SHEET WIRE DESIGNATION Copyright 2002 by Guardian Security Systems, Inc. All Rightyed DEC 2 2 2005 Tukwila Fire 1 FA -01 J �y o.• WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE F INITIATING CIRCUIT TWO #18 FPL/THHN RED (JACKET) S SIGNALING CIRCUIT - AUDI❑ TWISTED PAIR W/ SHIELD #14 FPL RED/BLACK CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE TWO 600V #12 AWG THHN/THWN TWO 600V #14 AWG THHN/THWN TWISTED TWO CONDUCTOR 300V #18 AWG FPL TW CABLE CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF CONDUIT SIZE MAXIMUM F 1/2" .12 SQUARE 3/4" SQUARE 1" .34 SQUARE 1-1/4" .60 SQUARE 1-1/2" .82 SQUARE 2" 1.34 SQUARE FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM DIMENSIONS AREA .244 0.D. .0467 .210 O.D. .0346 .156 O.D. .0191 CONDUIT FROM THE TABLE FILL DIMENSION FROM THE WIRE. LL NCH NCH NCH NCH NCH INCH N.E.C., CHP. 9, TABLE 4. WIRE DESIGNATION 1. ALL WALL -MOUNTED AUDIBLE & VISUAL SIGNALING APPLIANCES SHALL HAVE THEIR HEIGHTS ABOVE THE FINISHED FLOOR AT 80' TO BOTTOM. NFPA 72, 1999 EDITION, ALLOWS 80'-96" FOR VISUAL DEVICES (CH. 4-4.4) AND REQUIRES A MINIMUM OF 90' TO TOP FDR AUDIBLE DEVICES DR 6' FROM CEILING, WHICHEVER IS LOWER (CH. 4-3.5). FOR SLEEPING AREAS GREATER THAN 16' (LINEAR) VISIBLE N❑TIFICATI❑N SHALL BE WITHIN 16' OF PILLOW AND GREATER THAN OR EQUAL TO 24' FROM CEILING TO TOP OF LENS FOR 110cd (CH. 4-4.4.3.2) 2. ALL EQUIPMENT SHALL BE U.L. LISTED. 3. ELECTRICAL CONTRACTOR SHALL FURNISH ACCESS PANELS TO AREAS THAT REQUIRE SERVICING, TROUBLE SHO❑TING, ETC, 4. DO NOT DEVIATE FROM CONDUIT RUNS AS SHOWN ON FLOOR PLANS WITH❑UT PRIOR APPROVAL FROM SYSTEM SUPPLIER (GUARDIAN SECURITY SYSTEMS, INC., TEL (206)622-6545). FACTORS SUCH AS EXCESSIVE VOLTAGE DROP, ADDITIONAL PARTS, ENGINEERING, ETC., THAT ARE A RESULT OF CONDUIT RUN DEVIATIONS SHALL BE THE SOLE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. 5. DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIR -FLOW, NOR CLOSER THAN 3 FEET (900mm) FROM AN AIR SUPPLY DIFFUSER. 6. ALL FAN SHUTDOWN FUNCTIONS, DAMPER CLOSURES, AND ASSOCIATED MECHANICAL SYSTEM FIRE ALARM INTERFACE SHALL BE BY MECHANICAL CONTRACTOR. 7. ALL DUCT SMOKE DETECTORS SHALL BE MOUNTED BY THE MECHANICAL CONTRACTOR. ALL AIR VELOCITY TESTING SHALL BE PERFORMED BY THE MECHANICAL CONTRACTOR. 8. ALL 120VAC POWER REQUIREMENTS FOR THE FIRE ALARM SYSTEM SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR AND SHALL MEET ALL REQUIREMENTS OF THE AUTHORITIES HAVING JURISDICTION. 9. ALL FIRE ALARM DEVICE BACKBOXES, FIRE ALARM TERMINAL CABINETS, GUTTERS, JUNCTI❑N BOXES, AND ASSOCIATED CONDUITS SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. REFER TO FIRE ALARM SYMBOL LIST AND/OR MOUNTING DETAILS FOR ADDITIONAL INF❑RMATI❑N. SYSTEM SUPPLIER PROVIDED BACKBOXES SHALL BE INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. 10. SMOKE DETECTOR TESTING SHALL BE ACCOMPLISHED WITH TEST MAGNETS AS PER THE MANUFACTURER'S INSTRUCTIONS. 11. ALL WIRING, INITIATING DEVICES AND ANNUNCIAT❑R PANEL SHALL BE SUPERVISED TO THE PRINCIPAL POINT OF ANNUNCIATION. THE FIRE ALARM CONTROL PANEL TO SUPERVISE THE ANNUNCIATOR PANEL, ALL INITIATING AND INDICATING DEVICE CIRCUITS, 12. ALL WIRING SHALL BE CUT FOR IN AND OUT. WIRING SHALL NOT BE LOOPED THROUGH DEVICES. ALL SPLICED WIRE P❑SSESING SHIELDS SHALL HAVE SHIELDS SPLICED AND TAPED TO PREVENT GROUND FAULTS. 13. POINT AND COMMON ANNUNCIATION AND T -TAPPING (EXCEPT SLC LOOP) ARE PROHIBITED. 14. PROVIDE 3/4' CONDUIT FROM FIRE ALARM CONTROL PANEL TO TELEPHONE BACKBOARD FOR OWNER PROVIDED CENTRAL STATI❑N M❑NIT❑RING. 15. THE ALARM SYSTEM SHALL HAVE AN AUDIBILITY OF NOT LESS THAN 15dB ABOVE AMBIENT NOISE LEVELS. TESTING SHALL BE ACCOMPLISHED WITH A dB METER. 16. ALL FLOW SWITCHES SHALL BE 2 WIRE WITH N❑N-ELECTRONIC RETARD TYPE SIMILAR TO THE SYSTEM SENSOR MODEL "WFD SERIES' ONLY, 17. ALL DEVICES IN THE ALARM SYSTEM SHALL BE COMPATIBLE AND INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 18. FIRE ALARM SYSTEM INSTALLATION COMPANY SHALL BE UL LISTED (UUJS). 19. INSTALLATION SHALL BE IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE, NEC AND CONTRACT DRAWINGS 20. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ 21. THE FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF G.S.S. TECHNICIANS 22. A SET OF INSTALLATI❑N AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY G.S.S. FIELD TECHNICIANS ,N b3 0714.1ICE 2F -P 15cd EXIST, T❑RE RM. E La 2F MOVED EXISTING HEAT DETECTOR TRAINING RM. PS L2F EX \IT \\/ N O�ICE 2F -1- 2F N / ❑ r IC C❑NPEPE CE ROOM 2F ❑ ILE 2F N 15cd C 2F • C O'ICE 2F NEW ❑-f- C E 2F 15cd t_.2S 12/24 2F 2F TO NEAREST. EXISTING MANUAL PULL STATION AREA OF WORK BUILDING #3 FLOOR PLAN BATTERY SIZING CALCULATI❑N Job Name: HALLWOOD EDEN SYSTEMS Panel Location: BATTERY CALCS FOR ADD-ONS Date Performed: 01-17-2001 QTY. DEVICE NAME STD -BY( Amps) ALARM( Amps) 1 WHEEL: PS -12/24-8 13 SMOKE: 2451 7 STR: RSS( 15CD) 0. 0750 0. 0016 0. 0000 0. 0750 0. 1300 0. 3710 Tota l s = 0. 0766 Stand -By Load = 0.0766 Amps Alarm Load = Stand -By Time = 24 Hrs. Alarm Time = 0. 5760 0. 5760 Amps 5/60 Hrs. Stand -By = 1.84.Amp*Hrs Alarm = Total = Stand -By + Alarm = 1. 84 + 0. 05 = 1. 89 Amp*Hrs Multiply by De -Rating Factor of 1.25 ---> 0. 05 Amp)Hrs 1. 89 ) 1. 25 = 2. 36 WWWWWWWWWWWWWWWWWWWAWWWWWWWWWWWWWWWNEWWWWWWWWWWW * MINIMUM BATTERY SIZE = 2.36 Ampere*Hours NE NE WORST CASE VOLTAGE DROP CALCULATION Job Name: Circuit: Date Performed: HALLWOOD BUILDING #3 STROBE CIRCUIT 11-01-2001 8 STR: RSS( 15CD) at 0. 0530 Amps each = 0. 4240 Amps Circuit Length = 261 Ft to End Circuit Load = 0.4240 Amps Total = 0.4240 Amps Wire Size = #14 AWG Voltage = 24.0 Volts (Ckt. Load) * (Ckt. Length) * 21. 6 Voltage Drop = ) 100% (Circular Mi ls) * (Volts) ( 0. 4240 )I * ( 261 ) )0( 21. 6 Voltage Drop = * 100% ( 4i10 ) )1( ( 24. 0) Voltage Drop = 2. 42% A( VOLTAGE DROP = 2. 42% ) QUANTITY SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT 12/24 REMOTE POWER SUPPLY PS -12/24-8 WHEELOCK PROVIDED 66" AFF TO TOP ❑F MANUAL PULL STATION BNG-1 NOTIFIER 4S DEEP BOX WI 48" AFF SINGLE GANG RING TO CENTER 13 CONVENTIONAL 2451 PHOTOELECTRIC DETECTOR 2 8 NOTIFIER 4S DEEP BOX W/ CEILING 3-0 RING HEAT DETECTOR kirc (ABOVE CEILING) HD -601 NOTIFIER 4S DEEP BOX W/ ABOVE CEILING 3-0 RING HEAT DETECTOR E (EXISTING) EXISTING EXISTING EXISTING EXISTING FIRE ALARM STROBE RSS-2415W WHEELOCK 4S DEEP BOX NO RING 80" A.F.F. TO BOTTOM Fo FIRE ALARM MINI HORN VERIFY VERIFY IN FIELD IN FIELD 4S DEEP BOX NO RING 80" A.F.F. TO BOTTOM CI FIRE ALARM JUNCTI❑N BOX N/A BY ELECTRICIAN 4S BOX U.O.N. VERIFY IN FIELD FATC FIRE ALARM TERMINAL CABINET N/A BY ELECTRICIAN 18 x 18 x 6 VERIFY IN U.O.N. FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A EOL END OF LINE RESIST❑R N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.O.N. UNLESS OTHERWISE N/A NOTED N/A N/A N/A VL VERIFY L❑CATION N/A IN FIELD N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A r 1 1ST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 SYMBOLS LEGEND (+) FROM CONTROL PANEL -) <+) FROM FCPS SMOKE/HEAT DETECTORS E❑LR E❑LR ALARM STROBES AND HORN/ TROBES CC) z 0 (n LU WIRING DIAGRAMS PREVI❑US DEVICE JUNCTI❑N BOX MOUNTED ON CEILING SLAB IL 0 0 :0 0 HEAT DETECTOR JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT \o SMOKE/HEAT DETECTOR' TO NEXT DEVICE SUSPENDED ILLUMINATED CEILING SOKE/HEAT MOUNTING DIAGRAM ALARM STROBE R E O O O O O // 90" A.F.F. 4S DEEP BOX w/ 4S EXTENSION BOX 4" SQUARE DEEP BACK BOX WITH 1G TRIM RING HEIGHT REQUIREMENTS PULL STATION - STROBE WALL MOUNTED DEVICE MOUNTING ELEVATION DESCRIPTION FIRE DEPARTMENT REVISION - REPLACE ALL ABOVE CEILING WITH SMOKE DETECTORS J 5 U) LL 1- 0 0 0 N 0 0 0 z EDEN SYSTEMS LU 2E z m `0 - SCALE: GENERAL NOTES SYSTEM CALCULATIONS MOUNTING DIAGRAMS Copyright ' 2000 by Guardian Security Systems, Inc. All Rights Reserved ' I w a J I V J w CC I CO 0 T J F- LU SYSTEMS 006 z J 0. cc J Mw U. 1/8" = 1' DRAWN BY: MSH DESIGNED BY: FRANK CLOSE DATE: 11/01/00 \OB NUMBER: 52780 ,/ ie SHEET FA - O1 AT s. i A r r ar SHEET # DESCRIPTION FA -01 SHEET INDEX,SYMBOL LIST,GENERAL NOTES,WIREk DESIGNATIONS SYSTEM CALCULATIONS AND SEQUENCE OF OPERATION FA -02 FIRE ALARM—MOUNTING AND WIRING DIAGRAMS, RISER DIAGRAM AND FLOOR PLAN a l SHEET INDEX 1 ALL WALL -MOUNTED AUDIBLE & VISUAL SIGNALING APPLIANCES SHALL HAVE THEIR HEIGHTS ABOVE THE FINISHED FLOOR AT 90' TO BOTTOM NFPA 72, 1996 EDITION, ALLOWS 80'-96' FOR VISUAL DEVICES (CH 6-4 4) AND REQUIRES A MINIMUM OF 90' TO TOP FOR AUDIBLE DEVICES OR 6' FROM CEILING, WHICHEVER IS LOWER (CH 6-3 5) FOR SLEEPING AREAS GREATER THAN 16' (LINEAR) VISIBLE NOTIFICATION SHALL BE WITHIN 16' OF PILLOW AND GREATER THAN OR EQUAL TO 24' FROM CEILING TO TOP OF LENS FOR 110cd (CH 6-4 4 3 2) 2 ALL EQUIPMENT SHALL BE U L AND C S F M LISTED 3 ELECTRICAL CONTRACTOR SHALL FURNISH ACCESS PANELS TO AREAS THAT REQUIRE SERVICING, TROUBLE SHOOTING, ETC 4 DO NOT DEVIATE FROM CONDUIT RUNS AS SHOWN ON FLOOR PLANS WITHOUT PRIOR APPROVAL FROM SYSTEM SUPPLIER (GUARDIAN SECURITY SYSTEMS, INC, TEL (206)622-6545) FACTORS SUCH AS EXCESSIVE VOLTAGE DROP, ADDITIONAL PARTS, ENGINEERING, ETC, THAT ARE A RESULT OF CONDUIT RUN DEVIATIONS SHALL BE THE SOLE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR 5 DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIR -FLOW, NOR CLOSER THAN 3 FEET (900mri) FROM AN AIR SUPPLY DIFFUSER 6 ALL FAN SHUTDOWN FUNCTIONS, DAMPER CLOSURES, AND ASSOCIATED MECHANICAL SYSTEM FIRE-ALARM__INTERFACE SHALL BE BY MECHANICAL ti CONTRACTOR 7 ALL DUCT SMOKE DETECTORS SHALL BE MOUNTED -BY THE MECHANICAL CONTRACTOR DUCT SMOKE DETECTORS EXPOSED TO THE WEATHER SHALL BE WEATHER PROTECTED BY THE MECHANICAL CONTRACTOR ALL AIR VELOCITY TESTING SHALL BE PERFORMED BY THE MECHANICAL CONTRACTOR 8 ALL 120VAC POWER REQUIREMENTS FOR THE FIRE ALARM SYSTEM SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR AND SHALL MEET ALL REQUIREMENTS OF THE AUTHORITIES HAVING JURISDICTION 9 ALL FIRE ALARM DEVICE BACKBOXES, FIRE ALARM TERMINAL CABINETS, GUTTERS, JUNCTION BOXES, AND ASSOCIATED CONDUITS SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED REFER TO FIRE ALARM SYMBOL LIST AND/OR MOUNTING DETAILS FOR ADDITIONAL INFORMATION SYSTEM SUPPLIER PROVIDED BACKBOXES SHALL BE INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED 10 SMOKE DETECTOR TESTING SHALL BE ACCOMPLISHED WITH TEST MAGNETS AS PER THE MANUFACTURER'S INSTRUCTIONS t 11 ALL WIRING, INITIATING DEVICES AND ANNUNCIATOR PANEL SHALL BE SUPERVISED TO THE PRINCIPAL POINT OF ANNUNCIATION THE FIRE ALARM CONTROL PANEL TO SUPERVISE THE ANNUNCIATOR PANEL, ALL INITIATING AND INDICATING DEVICE CIRCUITS 12 ALL WIRING SHALL BE CUT FOR IN AND OUT, WIRING SHALL NOT -BE LOOPED THROUGH DEVICES 13 POINT AND COMMON ANNUNCIATION AND T -TAPPING (EXCEPT SLC LOOP) ARE PROHIBITED 14 PROVIDE 3/4' CONDUIT FROM FIRE ALARM CONTROL PANEL TO TELEPHONE BACKBOARD FOR OWNER PROVIDED CENTRAL STATION MONITORING 15 THE ALARM SYSTEM SHALL HAVE AN AUDIBILITY OF NOT LESS THAN 15dB ABOVE AMBIENT NOISE LEVELS TESTING SHALL BE ACCOMPLISHED WITH A dB METER 16 ALL FLOW SWITCHES SHALL BE 2 WIRE WITH NON -ELECTRONIC RETARD TYPE SIMILAR TO THE SYSTEM SENSOR MODEL 'WED SERIES' ONLY t- 17 ALL DEVICES IN THE ALARM SYSTEM SHALL BE COMPATIBLE AND INSTALLED PER MANUFACTURER'S SPECIFICATIONS 18 FIRE ALARM SYSTEM INSTALLATION COMPANY SHALL BE UL LISTED (UUJS) 19, INSTALLATION SHALL BE IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE, NEC AND CONTRACT DRAWINGS 20 ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ 21 THE FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF G S,S TECHNICIANS 22 A SET OF INSTALLATION AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND - - CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY G S S. = FIELD TECHNICIANS - - F sseesssssssss*exsesssesesxeseees*ese*xseesesesssssssesseseesse ;rt e s BATTERY SIZING CALCULATION s _ t Job Names Panel Locations Date Performed' HALLWOOD MAIN PANEL ADD-ON 02-04-2000 QTY DEVICE NAME STD-BY(Amps) ALARM<Amps) 13 HEAT' HD601 3 MOD_Ms BNG-1 3 SMOKE' 2451 O 0000 0 1950 O 0006 0 0006 O 0004 0 0300 Totals = 0 0010 Stand -By Load = 0 0010 Amps Alarm Stand -By Time = 24 Hrs Alarm 0 2256 Load = 0 2256 Amps Time = 5/60 Hrs Stand -By = 0 02 Amp*Hrs Alarm = 0. 02 Amp*Hrs Total = Stand -By + Alarm = 0.02 + 0 02 = 0 04 Amp*Hrs Multiply by De -Rating Factor of 1 25 ---> 0 04 s 1 25 = 0 05 sssssssssssssssssssssssssssss*sssssssssssssssss * MINIMUM BATTERY SIZE = 0 05 Ampere*Hours * s s sxse***e 'e*****s 's '*xs 's***s*s*****e*x*s*eer *** ssss*sssssesessessssssssssssssssssssssssssssssssss*sssssssssss x e BATTERY SIZING CALCULATION s s BE sssssssessesseesssssseseeeseesit'sssassseeeseesxeeesssesseeasees Job Name' HALLWOOD Panel LocatIon. REMOTE POWER SUPPLY (FCPS) Date Performed' 02-04-2000 QTY DEVICE NAME STD-BY(Amps) ALARM(Amps) 1 1 3 2 1 FCPS' BELL' WS' STR' STIR' FCPS-24 KMS -6 NS -2475W RSS( 15CD) WM3T O 0480 O 0000 O 0000 0. 0000 O 0000 O 0480 O 0300 O 4920 O 1060 O 0880 Totals = 0 0480 Stand -By Load = 0,0480 Amps Stand -By Time = 24 Hrs Stand -By = 1 15 Amp*Hrs Total = Stand -By + Alarm = 1 15 + 0 06 = 1 22 Amp*Hrs O 7640 Alar'm Load = 0 7640 Amps Alarm Time = 5/60 Hrs Alarm = 0 06 Amp*Hrs Multiply by De -Rating Factor of 1 25 ---) 1 22 * 1 25 = 1 52 **ins**sss*s*ss****sss**s********s*************s * MINIMUM BATTERY SIZE = 1 52 Ampere*Hours s s I sesesitRs*sssssssssee*eeseseeseeeseeeee**eeeeeeee — *****s*Iii.**i«sig***.*******s*s*ins******************************* NE s WORST CASE VOLTAGE DROP CALCULATION NE NE M ********ss*I ***ins**i******s**s*********iK********siA****s*****ins Job Name' HALLWOOD Circuits INDICATING CIRCUIT #1 Date Performed' 02-04-2000 3 H/S' NS -2475W at 0 1640 Amps each = 2 SR' RSS(15CD) at 0 0530 Amps each = 0 4920 Amps 0. 1060 Amps Circuit Length = 150 Ft to End Circuit Load = 0 5980 Amps Voltage Drop = Voltage Drop = Voltage Drop = < Ckt Load) s C Ckt Total = Wire Size Voltage Length) * (Circular Mils) ( 0 5980) s ( s (Volts) 150 ) s 0. 5980 Amps = #14 AWG = 24 0 Volts 21 6 - * 100X 21 6 ( 4110 1 967 ) AiC 24 0) WWssss****s**ori *****sig**ss* NI VOLTAGE DROP = 1 96/. * s NE eesiEeMxseeseeee*eesxssxexes x 1004 ssssssssssssssssssss;srssssssitssssssssselir*ssssssssssssssssssssit'ss E WORST CASE VOLTAGE DROP CALCULATION BiiE31F****3issl1E3iBi!«Ii WWWWAEAEi1E31E11****s31EBE3ii1E3A****■31EiffBEEMerlesllEifE********iIEilEik*** Job Name' HALLWOOD Circuit' EXTERIOR BELL/STROBE CIRCUIT Date Performed' 02-04-20001 1 BELL' KMS -6 at 0 0300 Amps each = 1 STR' WM3T at 0 0880 Amps each = O 0300 Amps O 0880 Amps Circuit Length = 50 Ft to End Circuit Load = 0 1180 Amps Voltage Drop = Voltage Drop = Voltage Drop = 0 13A (Ckt Load) * < Ckt -Total = 0 1180 Amps Wire Size = #14 AWG Voltage = 24 0 Volts Length) s 21 6 (Circular Mils) x (Volts) ( 0 1180 ) * ( 50 ) IN 21 6 ( 4110 ) N( 24 0) sssssssssssssssssssssssssss s } * * VOLTAGE DROP = 0'13h * s I s W*************************1 * 100/ x 100/ QUANTITY 1 1 SYMBOL - DESCRIPTION MODEL MANUFACTURER - BACKBOX MOUNTING HEIGHT FCPS AUDIO/VISUAL POWER SUPPLY FCPS-24 NOTIFIER FCPS PROVIDED 66" A.F F TO TOP 8112 EX CONTROL PANEL 8112 RADIONICS PROVIDED 66" A.F F TO TOP —3 © AREA SMOKE DETECTOR 2451 NOTIFIER (PHOTO -ELECTRIC) 8401-B 9 4 3 1 1 3 2 4S DEEP BOX W/ CEIUNG 3-0 RING 0 AREA HEAT DETECTOR HD -601 NOTIFIER 4S DEEP BOX W/ CEIUNG 3-0 RING ABOVE CEIUNG OC HEAT DETECTOR HD -601 NOTIFIER 4S DEEP BOX W/ CEIUNG 3-0 RING MANUAL PULL STATION BNG-1 NOTIFIER 4S DEEP BOX W/ 48" A.F F SINGLE GANG RING TO CENTER BELL ALARM KMS -6 NOTIFIER 4S DEEP BOX W/ VERIFY 1 GANG RING IN FIELD CD FIREROBE ALARM ST © FIRE ALARM HORN/STROBE WM3T WHEELOCK 1NS-2475W WHEELOCK RED SINGLE GANG BOX 90" A.F F TO BOTTOM 4S DEEP BOX NO RING 80" A F F TO BOTTOM 6) FIRE ALARM STROBE 1,RSS-2415W WHEELOCK RED 4S DEEP BOX NO RING 80" A.F F TO BOTTOM 0 FIRE ALARM JUNCTION BOX N/A BY ELECTRICIAN 4S BOX VERIFY IN U 0 N FIELD FATC FIRE ALARM TERMINAL CABINET N/A BY ELECTRICIAN 18 x 18 x 6 VERIFY IN U O N FIELD AFF ABOVE FINISHED FLOOR N/A N/A N/A N/A EOL END OF LINE RESISTOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A FBO FURNISHED BY OTHERS N/A N/A N/A N/A NOT APPLICABLE PI/A N/A N/A N/A UON UNLESS OTHERWISE tv/A NOTED N/A N/A N/A VL VERIFY LOCATION IN FIELD t/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A M A� C7 CM CO Nt 00 N t0 c0 0 N It) (0 N N 40 (0 0 N J W t-- ( SYMBOL LIST WIRE SCHEDULE 'AND CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE _ F INITIATING CIRCUIT "TWO #18 FPL RED (JACKET) S SIGNALING CIRCUIT ' TWO #14 FPL/THHN RED/BLACK CONDUIT FILL CHART NO OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V *12 AWG THHN/THWN 244 0 D 0467 TWO 600V #14 AWG THHN/THWN TWISTED 210 0 D 0346 TWO CONDUCTOR 300V fiB AWG FPL TW CABLE 156 D 0191 CONDUIT FILL L1kG C E P CALCULATE THE TOTAL AREA OF; THE WIRE BEING RUN IN THE CONDUIT FRO THE TABLE ABOVE CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM ALL DIMEN ION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE Without Commer CONDUIT SIZER MAXIMUM FILL ` As Noted In Red 1/2" 12 SQUARE INCH ��❑ Per The Attache( 3/4" 21 SQUARE INCH 1" .34 SQUARE INCH These plans have been reviewed 1-1/4" 60 SQUARE INCH Prevention Bureau for confcrm:a- 1-1 {2" 82 SQUARE INCH standards Acceptance is subjec 2 q 1 34 SQUARE INCH omissions which do not au+�honze FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N E C. CH G ordances The I adcauacv of des on rets tatally iq a WIRE DESIGNATION W Cr z J 0 0 N ED s Letter by The Tukwila Fire with current city to errors and v o,e,ors of adoptec sspons'b'I'ty for the ith the Gea'y^er Additions. deletions or revisions to these dra 'rigs a;t this date will void this acceptance and will require a resubmittal of rerVised aldwinya for subsequent appro DEVICE ACTION MANUAL STATION AREA HEAT/ DETECTOR ELEVATOR LOBBY DETECTOR EL ATOR swamSHAFT` DETECTOR TOP Of STAIRC i�T TER AIR DUT(E DETECTOR SPRIN(LEA ITWATER SWITCH SPRINKLER VALVE SWITCH SPRINKL POTA SWITCH lceptance plGw; SYSTEM ", F- IE - P CSD�INT�D PANEL TROUDLEBIIZAR YEIYEIYEIYEIYEIYEIYE1YES YE � � T EI Y (ALARM ORTROUBLE) YES YES YES YES YES YES YES YES YES YES YES DELL °'I YES YESYESYESYES NO YES NO NO NO NO ANNUNCIATE Aw FW.ARMC ORTROLTrROUBN YES YES YES VIES YES YES YES YES YES YES YES' ANI RE°A.ZiWATE AT (ALFRT ARM TROUBLE) YES YES YES YES YES YES YES YES YES YES YES ACTIVATE � FLOOR ABOVE 1 2 , YES YES YES No YES YES YES NO NO YES NO TFfRO1GH�) WT BUILDING YES YES YES fs4o YES YES YES NO NO YES NO RELE '�YESYESYES ON ONFLOOR OF ALARM NO I YES YES YES NO NO YES YES NO NO YES YrES NO NO NO NO NO NO YES Std DDAMPE NO NO NO YES NO NO NO NO NO NO NO *ON WIRING FAULT OR DEVICE TROUBLE OCT t _ i!E SEQUENCE OF OPERATION TO MATCH EXISTING - GENERAL NOTES SYSTEM CALCULATIONS SEQUENCE OF OPERATION subject to field test and inspector revention Bureau X00 By 1c. 5L0 w I— Q CO w J w CC J CC i r 0 U O 0 J J Q Q z co 0 at by UKWILA FIRE DEPARTMENT lease call 575-4407 nd give this job w ^ No and exact address for shut= down or restoration approval. FILE Z O H CD z to 617 INDUSTRY DRIVE, TUKWILA, INFORMATION w N SCALE>we SHEET TITLE , NO SCALE DRAWN BY JJD DESIGNED BY FRANK CLOSE DATE 2/4/00 Copyright _ 2000 by Guardian Security Systems, Inc. All Rights Reserved, JOB NUMBER- 52564 SHEET FA -01 - if IFBOWETTE F�Q'32000 t -4 —1 I Fr F — - - FROM CONTROL PANEL (-) IOW '111111110 SMOKE/HEAT DETECTORS EOLR 3 (+) FROM FCPS C-) EOLR ALARM STROBES AND HORN/STROBES SIGNALING CIRCUITS SIGNALING CIRCUTS iso MM • hi 3 4 9 10 R76 lasoi R175 Ilcs:i IPE CI 131 1 R176 3 kmoi R63 1=I I=1 R134 4 NOT USED 5 6 24VDC 7 8 k• :4 1' it as •. 783 FCPS MOUNTING DIAGRAM L FEED FROM EXISTING 8112 NAC IRETURN JUNCTION BOX MOUNTED ON CEILING SLAB PREVIOUS DEVICE 0 0 00 HEAT DETECTOR JUNCTION BOAC MOUNTED AGAINST CEILING SUPPORT SMOKE/HEAT DETECTOR WIRING DIAGRAMS TO NEXT DEVICE SUSPENDED ILLUMINATED CEILING SOKL/HII:AT MOUNTING DIAGRAM HEIGHT REQUIREMENTS - HEIGHT REQUIREMENTS PULL STATION — STROBE PULL STATION — HORN/STROBE WALL. MOUNTED DEVICE MOUNTING OVATIONS I 4S BOX cD FCPS-24 POVER SUPPLY TO 120VAC E—CIRCUIT F B.O. FINISHED FLOOR 66' AFF PCP13 MOUNTING DIAGRAM EXTERIOR BLL AND STRODE Ate H H H DIAGRAMMATIC ONLY TO 120VAC E—CIRCUIT - / F80 Z1= MANUAL PULL STATIONS Z2= ABOVE CEILING HEATS Z3= ON CEILING HEATS/SMOKES C1= SIGNALING CIRCUIT DESCRIPTION W Q 0 0 0 Cu 0 Z z 0 O F' 0 } J CCJ W CC 617 INDUSTRY DRIVE, TUKWILA, W J I -- W W ‘CALE 1/8. _ t, DRAWN BY JJD DESIGNED BY - FRANK CLOSE DATE. 2/2/00 JOB NUMBER. 52564 SHEET FA—O2,, ' — 1, — se_ _.1 N -11 MOUNTING DIAGRAMS I RISER DIAGRAM I FIRE ALARM LAYOUT ____ t/ L. ._../\r�./7•{ Cen.v�i�i C.. 4 rr�� Inn All I?fnh4� I?ocefrvcri JOB NUMBER. 52564 SHEET FA—O2,, ' — 1, — se_ _.1 N -11