FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
Site Address: Z \IALIJuMfy
%
G6
St'enant Name: (i,(\LL i/ RAN Y _ EaPe TA. Le New Tenant? ❑ - Yes
Ij Property Owner's Name' VVI...
DO R r U
Mailing Address: L100 ��5c iNik Q,w-v
) L2-/
City State Zip
King Co. Assessor's Tax No.:
Suite NumberFloor:
CONTACT PERSON -if there are questions about the submittal.
Name: KARINA VELIZ Day Telephone: 206-734-6276 x229
Company Name: GUARDIAN SECURITY SYSTEMS, INC
Mailing Address: 1743 — 1ST AVE S SEATTLE, WA 98134
City State Zip
E-mail Address: kveliz@guardians ecurity. com Fax Number: 206-341-9928
Valuation of Project (contractor's bid price): $ 7 1 .
Scope of Work (please provide detailed information): kld D' A(,OY A/‘
(J
PERMIT APPLICATION NOTES
Value of Construction —In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW T=om SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING R OR AUTHO�ED AGENT:
Signature: / \vr
Print Name: IJi,V t h fid V e
Date: L `
Day Telephone: 2-0Le - 31i
Plan PermitApp.doc 5/]4/]0 TFD FP Form 8
F
LE
ANDOVE ' PARK BAST T.I. - LANANT
FI
E ALARM SSTEM ADDITIOBUILDING
TUKWILA, WASHINGTON
TUKWILA ERE DEPARTr'sk.NT
e >< e a20:5-575-4407 and
11, e.6.,, �?;all
give this Fire Permit No.
l5— too
and exact address for shut-
down
hydown or restoration approval.
SHE
=T
DESCIPTIO\
FA -01
SHEET INDEX, SYMBOL LIST, WIRE DESIGNATIONS, AND
PARTIAL FLOOR FIRE ALARM PLAN
SHEET INDEX
QUANTITY
EX
EX
3
2
3
2
EX
EX
SYMBOL DESCRIPTION
MODEL
MANUFACTURER BACKBOX
MOUNTING HEIGHT
FACP
EX
FIRE ALARM
CONTROL PANEL
(EXISTING)
EXISTING EXISTING
EXISTING
VERIFY
IN FIELD
BPS
EX
REMOTE BOOSTER
POWER SUPPLY
(EXISTING)
PS -8
WHEELOCK
PROVIDED
66" A.F.F.
TO TOP
SMOKE DETECTOR
(CONVENTIONAL)
2W—B
SYSTEM
SENSOR
4—INCH
OCTAGONAL BOX
CEILING
FIRE ALARM
STROBE
STWC
WHEELOCK
4" SQUARE
DEEP BOX
CEILING
FIRE ALARM
HORN STROBE
HSWC
WHEELOCK
4" SQUARE
DEEP BOX
CEILING
HEAT DETECTOR
(CONVENTIONAL)
DT -135R SIEMENS
4—INCH
OCTAGONAL BOX
CEILING
®Ac HEAT DETECTOR
(ABOVE CEILING)
DT -135R SIEMENS
4—INCH
OCTAGONAL BOX
CEILING
®Ex HEAT DETECTOR
(EXISTING)
EXISTING
EXISTING
EXISTING
CEILING
�Ex MANUAL PULL STATION
(EXISTING)
EXISTING EXISTING
EXISTING
48" A.F.F.
TO CENTER
EX
EXISTING
DEVICE
N/A
N /A
N/A
N/A
A.F.F.
ABOVE FINISHED
FLOOR
N/A
N/A
N/A
N/A
EOL
END OF LINE
RESISTOR
N/A
N/A
N/A
N /A
F.B.O.
FURNISHED BY
OTHERS
N/A
N/A
N/A
N/A
RED
AS BUILT
ADD OR CHANGE
N/A
N/A
N/A
N/A
GREEN AS BUILT
REMOVE
N/A
N/A
N/A
N/A
BLUE
AS BUILT
NOTES TO CAD
N/A
N/A
N/A
N/A
SYMBOLS LEGEND
WIRE SCHEDULE AND CO\DUIT FILL CHART
Ev.
LT]
F
d
21
PARTIAL FLOOR FIRE ALARM PLAN
SCALE:
1. ALL EQUIPMENT SHALL BE U.L. LISTED
2. ACCESS PANELS TO AREAS THAT REQUIRE SERVICING, TROUBLESHOOTING ETC.
PROVIDED BY OTHERS
3. DO NOT DEVIATE FROM CONDUIT RUNS AS SHOWN ON FLOOR PLANS WITHOUT PRIOR
APPROVAL FROM SYSTEM SUPPLIER (GUARDIAN SECURITY SYSTEMS, INC. TEL.
206-622-6545). FACTORS SUCH AS EXCESSIVE VOLTAGE DROP, ADDITIONAL PARTS,
ENGINEERING, ETC. THAT ARE A RESULT OF CONDUIT RUN DEVIATIONS SHALL BE
THE SOLE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR.
4. DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIRFLOW, NOR CLOSER THAN
3'-0" (900mm) FROM AN AIR SUPPLY DIFFUSER.
5. ALL 120VAC POWER REQUIREMENTS FOR THE FIRE ALARM SYSTEM SHALL BE
FURNISHED BY THE ELECTRICAL CONTRACTOR AND SHALL MEET ALL REQUIREMENTS
OF THE AUTHORITY HAVING JURISDICTION.
6. ALL FIRE ALARM DEVICE BACK BOXES, FIRE ALARM TERMINAL CABINETS, GUTTERS,
JUNCTION BOXES AND ASSOCIATED CONDUITS SHALL BE FURNISHED AND INSTALLED
BY THE ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. REFER TO FIRE
ALARM SYMBOL LIST AND/OR MOUNTING DETAILS FOR ADDITIONAL INFORMATION.
SYSTEM SUPPLIER PROVIDED BACK BOXES SHALL BE INSTALLED BY ELECTRICAL
CONTRACTOR UNLESS OTHERWISE NOTED.
7. DETECTOR TESTING SHALL BE ACCOMPLISHED PER THE MANUFACTURER'S
INSTRUCTIONS.
8. ALL WIRING, INITIATING DEVICES AND ANNUNCIATOR PANELS SHALL BE
SUPERVISED TO THE PRINCIPAL POINT OF ANNUNCIATION. THE FIRE ALARM
CONTROL PANEL TO SUPERVISE THE ANNUNCIATOR PANEL, ALL INITIATING AND
INDICATING DEVICE CIRCUITS.
9. ALL WIRING SHALL BE CUT FOR IN AND OUT. V/IRING SHALL NOT BE LOOPED
THROUGH DEVICES. ALL SPLICED WIRE POSSESSING SHIELDS SHALL HAVE SHIELDS
SPLICED AND TAPPED TO TAPED TO PREVENT GROUND FAULTS.
10. POINT AND COMMON ANNUNCIATION AND T—TAPPING (EXCEPT SLC LOOP) ARE
PROHIBITED.
11. THE ALARM SYSTEM SHALL HAVE AN AUDIBILITY OF NOT LESS THAN 15dB ABOVE
AMBIENT NOISE LEVELS. TESTING SHALL BE ACCOMPLISHED WITH A dB METER.
12. ALL DEVICES IN THE ALARM SYSTEM SHALL BE COMPATIBLE AND INSTALLED PER
MANUFACTURER'S SPECIFICATIONS.
13. FIRE ALARM SYSTEM INSTALLATION COMPANY SHALL BE U.L. LISTED (UUJS).
14. INSTALLATION SHALL BE IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE,
NEC AND CONTRACT DRAWINGS.
15. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ.
16. THE FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF G.S.S.
TECHNICIANS.
17. A SET OF INSTALLATION AS—BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND
CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY G.S.S.
FIELD TECHNICIANS.
3/16" = 1'0"
75cd
TO EXISTING
POWER SUPPLY
oWf ith'ZAJ lf. Comments
As Noted r,,? ;=,iii
Ci Per The At ch d Letter
1 --?.se plans have been reviewed by The Tukwila Fire
' ntion Bureau for conforn;,.mce with current City
';.ndards. Acceptance i a subject to errors and
nissinns which dc, not authorize violations of adopted
.::ndards and ordinances. The responslhility for the
decuacy of design res; totally with the designer.
Additions, deletions or revisions to these drawings after
this date will void this acceptance and v ili require a
resubnnitial of revised drawings for subsequent approval
Final acceptance is subject to field test and inspection b�
The Tukwila Fire Prevention Bureau.
Date: -,),1- (2 By:
%
NORTH
NOTICE
A completed, signed, Tukwila
Fire Department Pre-test
Certificate must be presented
to the Inspector prior to
commencement of Acceptance
Testing of any Fire Alarm
and Detection Systems.
Failure of test will result
in a Re -inspection Fee and
termination of the testing
KEY PLAN
AREA OF WORK
LOCATION OF EXISTING
POWER SUPPLY
WIRE DESIGNATION
GENERAL NOTES
PAID
APR 2 4 2813
' UKVVIL,A FIRE
Cc P0/ s/
Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved
1743 IST AVE. SO., SEATTLE, WASHINGTON
FAX (206) 628-4990
TEL. (206) 622-6545
RELEASE/REVISIONS
REV. BY:
0
0
WIRE DESIGNATI❑N
SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE
I
P
S
INITIATION CIRCUIT TWO #16 FPLP
DEVICE POWER TWO #1 4 FPLP
SIGNALING CIRCUIT TWO #14 FPLP
DESCRIPTION
CONDUIT FILL CHART
NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA
TWO 600V #12 AWG THHN/THWN .244 0.D. .0467
TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346
TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191
CONDUIT FILL
CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE
ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM
THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE.
CONDUIT SIZE MAXIMUM FILL
1/2" .12 SQUARE INCH
3/4" .21 SQUARE INCH
1" .34 SQUARE INCH
1-1/4" .60 SQUARE INCH
1-1 /2" .82 SQUARE INCH
2" 1.34 SQUARE INCH
FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4.
Ev.
LT]
F
d
21
PARTIAL FLOOR FIRE ALARM PLAN
SCALE:
1. ALL EQUIPMENT SHALL BE U.L. LISTED
2. ACCESS PANELS TO AREAS THAT REQUIRE SERVICING, TROUBLESHOOTING ETC.
PROVIDED BY OTHERS
3. DO NOT DEVIATE FROM CONDUIT RUNS AS SHOWN ON FLOOR PLANS WITHOUT PRIOR
APPROVAL FROM SYSTEM SUPPLIER (GUARDIAN SECURITY SYSTEMS, INC. TEL.
206-622-6545). FACTORS SUCH AS EXCESSIVE VOLTAGE DROP, ADDITIONAL PARTS,
ENGINEERING, ETC. THAT ARE A RESULT OF CONDUIT RUN DEVIATIONS SHALL BE
THE SOLE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR.
4. DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIRFLOW, NOR CLOSER THAN
3'-0" (900mm) FROM AN AIR SUPPLY DIFFUSER.
5. ALL 120VAC POWER REQUIREMENTS FOR THE FIRE ALARM SYSTEM SHALL BE
FURNISHED BY THE ELECTRICAL CONTRACTOR AND SHALL MEET ALL REQUIREMENTS
OF THE AUTHORITY HAVING JURISDICTION.
6. ALL FIRE ALARM DEVICE BACK BOXES, FIRE ALARM TERMINAL CABINETS, GUTTERS,
JUNCTION BOXES AND ASSOCIATED CONDUITS SHALL BE FURNISHED AND INSTALLED
BY THE ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. REFER TO FIRE
ALARM SYMBOL LIST AND/OR MOUNTING DETAILS FOR ADDITIONAL INFORMATION.
SYSTEM SUPPLIER PROVIDED BACK BOXES SHALL BE INSTALLED BY ELECTRICAL
CONTRACTOR UNLESS OTHERWISE NOTED.
7. DETECTOR TESTING SHALL BE ACCOMPLISHED PER THE MANUFACTURER'S
INSTRUCTIONS.
8. ALL WIRING, INITIATING DEVICES AND ANNUNCIATOR PANELS SHALL BE
SUPERVISED TO THE PRINCIPAL POINT OF ANNUNCIATION. THE FIRE ALARM
CONTROL PANEL TO SUPERVISE THE ANNUNCIATOR PANEL, ALL INITIATING AND
INDICATING DEVICE CIRCUITS.
9. ALL WIRING SHALL BE CUT FOR IN AND OUT. V/IRING SHALL NOT BE LOOPED
THROUGH DEVICES. ALL SPLICED WIRE POSSESSING SHIELDS SHALL HAVE SHIELDS
SPLICED AND TAPPED TO TAPED TO PREVENT GROUND FAULTS.
10. POINT AND COMMON ANNUNCIATION AND T—TAPPING (EXCEPT SLC LOOP) ARE
PROHIBITED.
11. THE ALARM SYSTEM SHALL HAVE AN AUDIBILITY OF NOT LESS THAN 15dB ABOVE
AMBIENT NOISE LEVELS. TESTING SHALL BE ACCOMPLISHED WITH A dB METER.
12. ALL DEVICES IN THE ALARM SYSTEM SHALL BE COMPATIBLE AND INSTALLED PER
MANUFACTURER'S SPECIFICATIONS.
13. FIRE ALARM SYSTEM INSTALLATION COMPANY SHALL BE U.L. LISTED (UUJS).
14. INSTALLATION SHALL BE IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE,
NEC AND CONTRACT DRAWINGS.
15. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ.
16. THE FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF G.S.S.
TECHNICIANS.
17. A SET OF INSTALLATION AS—BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND
CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY G.S.S.
FIELD TECHNICIANS.
3/16" = 1'0"
75cd
TO EXISTING
POWER SUPPLY
oWf ith'ZAJ lf. Comments
As Noted r,,? ;=,iii
Ci Per The At ch d Letter
1 --?.se plans have been reviewed by The Tukwila Fire
' ntion Bureau for conforn;,.mce with current City
';.ndards. Acceptance i a subject to errors and
nissinns which dc, not authorize violations of adopted
.::ndards and ordinances. The responslhility for the
decuacy of design res; totally with the designer.
Additions, deletions or revisions to these drawings after
this date will void this acceptance and v ili require a
resubnnitial of revised drawings for subsequent approval
Final acceptance is subject to field test and inspection b�
The Tukwila Fire Prevention Bureau.
Date: -,),1- (2 By:
%
NORTH
NOTICE
A completed, signed, Tukwila
Fire Department Pre-test
Certificate must be presented
to the Inspector prior to
commencement of Acceptance
Testing of any Fire Alarm
and Detection Systems.
Failure of test will result
in a Re -inspection Fee and
termination of the testing
KEY PLAN
AREA OF WORK
LOCATION OF EXISTING
POWER SUPPLY
WIRE DESIGNATION
GENERAL NOTES
PAID
APR 2 4 2813
' UKVVIL,A FIRE
Cc P0/ s/
Copyright 2013 by Guardian Security Systems, Inc. All Rights Reserved
1743 IST AVE. SO., SEATTLE, WASHINGTON
FAX (206) 628-4990
TEL. (206) 622-6545
RELEASE/REVISIONS
REV. BY:
0
0
DESCRIPTION
DATE
04/22/13
-aaaa
ca
W
V
9-
W
co
J E -v#
' (no
z
0W�
Ea ET?'
(10 2>U)
W�1.3
2 oc
Ct cc p
Z
C. <...
1WC NJ
LL +
0
0
�r.r.
-CALE: AS NOTED
Z
d
LL
DRAWN BY:
D. GARCIA
DESIGNED BY:
K. HEIGHTON
04/22/13
DATE:
BACKROUND PLAN PROVIDED BY:
\0B NUMBER:10014
SHEET
FA -01
ANDOVE ' PARS EAST T.I. LANANT
FIRE ALARM S
STEM ADDITION - BLJILDIN
KWILA, WASHINGTON
D
TUKWILA FIRE DEPARTMENT
Please I 205-575-4407 and
give this Fire Permit No.
and e: ct address for shut-
down or restoration approval.
SHEET #
DESCIPTIO\
FA— 01
SHEET INDEX, SYMBOL LIST, WIRE DESIGNATIOI\
PARTIAL FLOO FIRE ALARM PLAN
S, AND
SHEET INDEX
QUANTITY
EX
EX
3
2
3
2
1
EX
EX
SYMBOL DESCRIPTION
MODEL
MANUFACTURER BACKBOX
MOUNTING HEIGHT
FACP
EX
BPS
EX
FIRE ALARM
CONTROL PANEL
(EXISTING)
REMOTE BOOSTER
POWER SUPPLY
(EXISTING)
EXISTING EXISTING
EXISTING
VERIFY
IN FIELD
PS -8
WHEELOCK
PROVIDED
66" A.F.F.
TO TOP
SMOKE DETECTOR
(CONVENTIONAL)
2W -B
SYSTEM
SENSOR
4 -INCH
OCTAGONAL BOX
CEILING
FIRE ALARM
STROBE
STWC
WHEELOCK
4" SQUARE
DEEP BOX
CEILING
FIRE ALARM
HORN STROBE
HSWC
WHEELOCK
4" SQUARE
DEEP BOX
CEILING
HEAT DETECTOR
(CONVENTIONAL)
DT -135R SIEMENS
4 -INCH
OCTAGONAL BOX
CEILING
®Ac HEAT DETECTOR
(ABOVE CEILING)
DT -135R SIEMENS
4 -INCH
OCTAGONAL BOX
CEILING
®Ex HEAT DETECTOR
(EXISTING)
EXISTING
EXISTING
EXISTING
CEILING
DEx MANUAL PULL STATION EXISTING
(EXISTING)
EXISTING
EXISTING
48" A.F.F.
TO CENTER
EX
EXISTING
DEVICE
N/A
N /A
N/A
N/A
A.F.F.
ABOVE FINISHED
FLOOR
N/A
N /A
N/A
N/A
EOL
END OF LINE
RESISTOR
N /A
N/A
N/A
N/A
F.B.O.
FURNISHED BY
OTHERS
N/A
N/A
N/A
N /A
RED
AS BUILT
ADD OR CHANGE
N/A
N/A
N/A
N/A
GREEN AS BUILT
REMOVE
N/A
N/A
N/A
N/A
BLUE
AS BUILT
NOTES TO CAD
N/A
N/A
N/A
N/A
J
15cd
EOL
21—c
•
J1.._..._..
21 !
3...( 1'
tt.1
TO EXISTI G
POWER SUP LY
l
/RIo
AC
30cd
21 �.
15cd
IFJ
•
•
o-- 21
15cd
21
75cd
EX
Without Comments
As Noted in Red
0 Per The Attached Letter
IChese plans have been reviewed by The Tukwila Fire
r; ration Bureau for cnnforrnance with current City
' ndards. Accept ancc irs, subject to errors and
1..'' r ;sior s which do noir authorize violations of adopted
Fi dards a�-�c� or'sir:oncns. The responsibility for the
EX uuacy of deign i-:�. is totally with the designer,
1:tions, deletions rdii ort evasions to these drawings after
_: j to will void mis cceptance and will require a
fesubmittai of revised drawings for subsequent approval
='nal acceptance is subject to field test and Inspection b
rle Tukwila Fire Prevention Bureau.
gate: `I-�J-17 By;
'll
PARTIAL FLOOR FIRE ALARM PLAN
SCALE:
SYMBOLS LEGEND
WIRE SCHEDULE A\D CONDUIT FILL C
AT
WIRE DESIGNATION
1. ALL EQUIPMENT SHALL BE U.L. LISTED
2. ACCESS PANELS TO AREAS THAT REQUIRE SERVICING, TROUBLESHOOTING ETC.
PROVIDED BY OTHERS
3. DO NOT DEVIATE FROM CONDUIT RUNS AS SHOWN ON FLOOR PLANS WITHOUT PRIOR
APPROVAL FROM SYSTEM SUPPLIER (GUARDIAN SECURITY SYSTEMS, INC. TEL.
206-622-6545). FACTORS SUCH AS EXCESSIVE VOLTAGE DROP, ADDITIONAL PARTS,
ENGINEERING, ETC. THAT ARE A RESULT OF CONDUIT RUN DEVIATIONS SHALL BE
THE SOLE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR.
4. DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIRFLOW, NOR CLOSER THAN
3'-0" (900mm) FROM AN AIR SUPPLY DIFFUSER.
5. ALL 120VAC POWER REQUIREMENTS FOR THE FIRE ALARM SYSTEM SHALL BE
FURNISHED BY THE ELECTRICAL CONTRACTOR AND SHALL MEET ALL REQUIREMENTS
OF THE AUTHORITY HAVING JURISDICTION.
6. ALL FIRE ALARM DEVICE BACK BOXES, FIRE ALARM TERMINAL CABINETS, GUTTERS,
JUNCTION BOXES AND ASSOCIATED CONDUITS SHALL BE FURNISHED AND INSTALLED
BY THE ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. REFER TO FIRE
ALARM SYMBOL LIST AND/OR MOUNTING DETAILS FOR ADDITIONAL INFORMATION.
SYSTEM SUPPLIER PROVIDED BACK BOXES SHALL BE INSTALLED BY ELECTRICAL
CONTRACTOR UNLESS OTHERWISE NOTED.
7. DETECTOR TESTING SHALL BE ACCOMPLISHED PER THE MANUFACTURER'S
INSTRUCTIONS.
8. ALL WIRING, INITIATING DEVICES AND ANNUNCIATOR PANELS SHALL BE
SUPERVISED TO THE PRINCIPAL POINT OF ANNUNCIATION. THE FIRE ALARM
CONTROL PANEL TO SUPERVISE THE ANNUNCIATOR PANEL, ALL INITIATING AND
INDICATING DEVICE CIRCUITS.
9, ALL WIRING SHALL BE CUT FOR IN AND OUT. WIRING SHALL NOT BE LOOPED
THROUGH DEVICES. ALL SPLICED WIRE POSSESSING SHIELDS SHALL HAVE SHIELDS
SPLICED AND TAPPED TO TAPED TO PREVENT GROUND FAULTS.
10. POINT AND COMMON ANNUNCIATION AND T -TAPPING (EXCEPT SLC LOOP) ARE
PROHIBITED.
11. THE ALARM SYSTEM SHALL HAVE AN AUDIBILITY OF NOT LESS THAN 15dB ABOVE
AMBIENT NOISE LEVELS. TESTING SHALL BE ACCOMPLISHED WITH A dB METER.
12. ALL DEVICES IN THE ALARM SYSTEM SHALL BE COMPATIBLE AND INSTALLED PER
MANUFACTURER'S SPECIFICATIONS.
13. FIRE ALARM SYSTEM INSTALLATION COMPANY SHALL BE U.L. LISTED (UUJS).
14. INSTALLATION SHALL BE IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE,
NEC AND CONTRACT DRAWINGS.
15. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ.
16. THE FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF G.S.S.
TECHNICIANS.
17. A SET OF INSTALLATION AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND
CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY G.S.S.
FIELD TECHNICIANS.
3/16" = 1'0"
NORTH
* Shs tl ✓tw,o . L.C.=.O, 1,{1m.,,
giwY cc•,V.," att.
NOTICE
completed, signed, Tukwila
Fire Department Pre-test
Certificate must be presented
to the Inspector prior to
commencement of Acceptance
Testing of any Fire Alarm
and (;Detection Systems.
Failure of test will result
in a Re -inspection Fee and
termination of the testing
7 LOCATION OF EXISTING
POWER SUPPLY
KEY PLAN
GENERAL NOTES
Copyright 2013; by Guardian Security Systems,
1
PAID
WR 24 2013
TUKWILA FIRk
mac_ *A/
Inc. All Rights Reserved
0
1,0
00
1743 IST AVE. SO., SEATTLE, WASHINGTON
FAX (206) 628-4990
TEL. (206) 622-6545
U)
z
0
v)
w
w
cn
UJJ
W
REV. BY:
WIRE DESIGNATIDN
SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE
I
P
S
INITIATION CIRCUIT TWO #16 FPLP
DEVICE POWER TWO #14 FPLP
SIGNALING CIRCUIT TWO #14 FPLP
CONDUIT FILL CHART
0
z
NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA
TWO 600V #12 AWG THHN/THWN .244 0.D. .0467
TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346
TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0,;D. .0191
CONDUIT FILL
CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE
ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM
THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE.
CONDUIT SIZE MAXIMUM FILL
1/2" .12 SQUARE INCH
3/4" .21 SQUARE INCH
1" .34 SQUARE INCH
1-1/4" .60 SQUARE INCH
1-1/2" .82 SQUARE INCH
2" 1.34 SQUARE INCH
FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4.
WIRE DESIGNATION
1. ALL EQUIPMENT SHALL BE U.L. LISTED
2. ACCESS PANELS TO AREAS THAT REQUIRE SERVICING, TROUBLESHOOTING ETC.
PROVIDED BY OTHERS
3. DO NOT DEVIATE FROM CONDUIT RUNS AS SHOWN ON FLOOR PLANS WITHOUT PRIOR
APPROVAL FROM SYSTEM SUPPLIER (GUARDIAN SECURITY SYSTEMS, INC. TEL.
206-622-6545). FACTORS SUCH AS EXCESSIVE VOLTAGE DROP, ADDITIONAL PARTS,
ENGINEERING, ETC. THAT ARE A RESULT OF CONDUIT RUN DEVIATIONS SHALL BE
THE SOLE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR.
4. DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIRFLOW, NOR CLOSER THAN
3'-0" (900mm) FROM AN AIR SUPPLY DIFFUSER.
5. ALL 120VAC POWER REQUIREMENTS FOR THE FIRE ALARM SYSTEM SHALL BE
FURNISHED BY THE ELECTRICAL CONTRACTOR AND SHALL MEET ALL REQUIREMENTS
OF THE AUTHORITY HAVING JURISDICTION.
6. ALL FIRE ALARM DEVICE BACK BOXES, FIRE ALARM TERMINAL CABINETS, GUTTERS,
JUNCTION BOXES AND ASSOCIATED CONDUITS SHALL BE FURNISHED AND INSTALLED
BY THE ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. REFER TO FIRE
ALARM SYMBOL LIST AND/OR MOUNTING DETAILS FOR ADDITIONAL INFORMATION.
SYSTEM SUPPLIER PROVIDED BACK BOXES SHALL BE INSTALLED BY ELECTRICAL
CONTRACTOR UNLESS OTHERWISE NOTED.
7. DETECTOR TESTING SHALL BE ACCOMPLISHED PER THE MANUFACTURER'S
INSTRUCTIONS.
8. ALL WIRING, INITIATING DEVICES AND ANNUNCIATOR PANELS SHALL BE
SUPERVISED TO THE PRINCIPAL POINT OF ANNUNCIATION. THE FIRE ALARM
CONTROL PANEL TO SUPERVISE THE ANNUNCIATOR PANEL, ALL INITIATING AND
INDICATING DEVICE CIRCUITS.
9, ALL WIRING SHALL BE CUT FOR IN AND OUT. WIRING SHALL NOT BE LOOPED
THROUGH DEVICES. ALL SPLICED WIRE POSSESSING SHIELDS SHALL HAVE SHIELDS
SPLICED AND TAPPED TO TAPED TO PREVENT GROUND FAULTS.
10. POINT AND COMMON ANNUNCIATION AND T -TAPPING (EXCEPT SLC LOOP) ARE
PROHIBITED.
11. THE ALARM SYSTEM SHALL HAVE AN AUDIBILITY OF NOT LESS THAN 15dB ABOVE
AMBIENT NOISE LEVELS. TESTING SHALL BE ACCOMPLISHED WITH A dB METER.
12. ALL DEVICES IN THE ALARM SYSTEM SHALL BE COMPATIBLE AND INSTALLED PER
MANUFACTURER'S SPECIFICATIONS.
13. FIRE ALARM SYSTEM INSTALLATION COMPANY SHALL BE U.L. LISTED (UUJS).
14. INSTALLATION SHALL BE IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE,
NEC AND CONTRACT DRAWINGS.
15. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ.
16. THE FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF G.S.S.
TECHNICIANS.
17. A SET OF INSTALLATION AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND
CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY G.S.S.
FIELD TECHNICIANS.
3/16" = 1'0"
NORTH
* Shs tl ✓tw,o . L.C.=.O, 1,{1m.,,
giwY cc•,V.," att.
NOTICE
completed, signed, Tukwila
Fire Department Pre-test
Certificate must be presented
to the Inspector prior to
commencement of Acceptance
Testing of any Fire Alarm
and (;Detection Systems.
Failure of test will result
in a Re -inspection Fee and
termination of the testing
7 LOCATION OF EXISTING
POWER SUPPLY
KEY PLAN
GENERAL NOTES
Copyright 2013; by Guardian Security Systems,
1
PAID
WR 24 2013
TUKWILA FIRk
mac_ *A/
Inc. All Rights Reserved
0
1,0
00
1743 IST AVE. SO., SEATTLE, WASHINGTON
FAX (206) 628-4990
TEL. (206) 622-6545
U)
z
0
v)
w
w
cn
UJJ
W
REV. BY:
0
0
DESCRIPTION
0
z
4
iY
Il
0
'6M
DATE
N
N
d
a
2<<aaa
CO
0W
Z
F-0
m 5z
(/)O
0Wm
z
1— o Ct-
` D
mi
(1) >i.v4
< Cr>
co
Dolic
J Z
LUcr
Q
NE-
1
0
0
z
0.
11J
LL
CALE: AS NOTED
DRAWN BY:
D. GARCIA
DESIGNED BY:
K. HEIGHTON
DATE: 04/22/13
BACKROUND PLAN PROVIDED BY:
..JOB NUMBER: 100 -4-1-1/
SHEET
FA -01