Loading...
HomeMy WebLinkAboutPP - 819 INDUSTRY DR - SYSTEM DESIGN & INTEGRATION - PERMITS AND PLANS819 INDUSTRY DR ASSOCIATED PERMITS 98-F-089 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 819 Industry Drive, Tukwila, 98188 Suite Number: Bldg 19 Floor: Tenant Name: Tukwila Commerce Center New Tenant? E - Yes ❑ - No Property Owner's Name: CWWA Tuwkila 1 LLC c/o Kidder Mailing Address: PO Box 681897 Charlotte, CA 28216 CONTACT PERSON -if there are questions about the submittal. Name: Casey Walsh Day Telephone: 206.331.6206 252304901 City Company Name: Guardian Security Systems Mailing Address:1743 First Ave South, Seattle, WA 98134 State Zip cwalsh@guardiansecurity.com City State Zip E-mail Address: Fax Number: 206.628.4990 Total number of new/relocated devices or sprinkler heads: 1 Valuation of Project (contractor's bid price): $ 250.00 Scope of Work (please provide detailed information): Installation of an AES radio transmitter to monitor the existing FACP PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: v /� Print Name: asey Walsh Day Telephone: 206.331.6206 Plan Permit App.doc 1/2/13 TFD FP Form 8 A B 9<c - BATTERY CALCULATIONS FORM Pacific gul bldg 19 suite JOB NAME" 665 Current Draw Worksheet Device Number of Devices Current per Device scan by Current Alarm Current 5207 Fire Control /Communicator 1 Standby: 12UmA Alarm: 400mA 120 400.000 5210 Zone Expander 1 Standby: 40mA Alarm: 40mA 40 40 000 5220 Direct Connect Module 0 Standby: 50mA Alarm: 50mA 0 0.000 5230 Remote Annunciator (7 max.) 0 Standby: 60mA Alarm: 120mA 0 0.000 4180 Status Display 0 Standby: 2UmA Alarm: 140mA 0 0.000 7181 Zone Converter 0 standby: 35mA Alarm: 65mA 0 0.000 Current Subtotals (In mA) 160 44U.UW Smoke Detectors BRK-2400 Smoke detector 60 Standby:.12UmA Alarm: 70mA 7.2 4200.000 Racal BeamMaster Beam Smoke Detector w/ remote station 0 -Standby: 4. /MA Alarm: 29.7mA 0 0.000 'tandoy: mA Alarm: mA 0 Current Subtotals (in mA) 7.2 42UU.000 Pro - Comm, Inc. Confidential Continued page 2 4/2/98 Page 1 • E Notification Devices Current Used Total (Amps) WH -125182 Horn/strobe 0.163 U.000 WH -126601 Strobe only 1 0.115 U.115 AS-M10BPV424 Amseco bell 1 0 063 0.063 MIZ-24-WM Mini horn/strobe 23 0.127 2.921 Mini horn Federal Signal 460 024W 0.015 0.0(10 WH - 114911 WS3T-24VFR 117 Candela Outdoor Strobe 0.115 0.000 WH - 127473 RSS-2475W-FR 75 Candela Strobe 0.133 0.000 WH - 127474 RSS-24110W-FR 110 Candela Strobe 0.161 0.000 WH - 125023 MT -12/24-R Fire Horn 0 023 U.000 WH - 125355 MT-24-IS-VFR 75 Candela horn/strobe 0.223 0.000 WH - 125025 MT-24-WM-VFR 117 Candela horn/strobe 0.111 0.000 WH - 127806 NS -241575W -FR 15/75 Candela mini horn/strobe 0.086 0.000 WH - 127808 NS -2475W -FR 75 Candela mini horn/strobe 0.154 0.000 WH - 127809 NS -24110W -FR 110 Candela mini horn/strobe 0.181 0.000 i. d ,;i; III ri:;i iL Current SUbtotais (In mA) ,I lir 4i :,,,fbv11 'I-199.w° 1Total Current ratings of all devices in system (add A-D)(in mA) Total Current ratings coverted to amperes (X .001) 1tif.2UU W //39.0 0.16/ 0 iQ D ■ Battery Calculations • a -r pe -iso curren ro e urren •raw Worksheet (Row E) 'um r- • s .n• • ours • an. or'• 72, Chapter 1, 1-5.2.5 'u ipy ines•an•: o a a arm curren om e curren • raw worksheet (Row E)11 Alarm sounding period in hours (for example, 5 minutes = .084 hours.) Total Standby Current 0.1672 24 Total Alarm Current qu Ili ill �Irl II 41�IP �l nllll� r lit, I:II I1 lihi;l::lilili0 =MANI /III�� „I0111 1111';'1 /I 111 ©' u' ip y Ines • an• u ipy ine g .y . o a amper- ours required) 7.739 0.084 Pro - Comm, Inc. Confidential 5.5954512 L!IIII1IIII1III, 'III„I.IIIIIIIG!Illll1l1il 4/2/98 Page 2 // ... VVAREHOUSE CoNTINIUE 62 I N Cr° 7.ONE La".:* LR CARPET CONTINUED ><ISTINCr EoLp, - CA\RPET PACIFIC GULF', t5UILPINIG 19 SUITE 6(,5 N©T TO SCALE S ALARM MONITORING PROVIDED BY PROw-CO (425) 774-9099 1-8'00-774-9099 r(Cont., existing zone) (From existing circuit) (From existing zone) FIREALARM CONTROL PANEL TE Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city 1 standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted i standards and ordinances. The responsibilityloFthe adequacy of design rests totally with the designer. i Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention 8 Date: FUKWILA FIRE DEPARTIV1" Please call: 575-4407 and give this job No. n C56cI and exact address for shut, down or restoration approvai. N A i(NOT ES ;\°t s o This job involves expanding the existing Fire Alarm System to accommodate the new tenant improvements. Pro -Comm will be tying into the existing FACP. One new fire horn strobe will be added to existing circuit. Two new smoke detectors will be added to existing zone. All other building devices remain intact and are not part. of this TI. Fire Horn Strobe will be installed 80" from floor to the bottom of the box. Smoke Detectors will be installed on the ceilings. acific If erities, 1 rive • -c 3 VIE. • EST 25) 774-9 99 or 1-800-774-90 TE 11 51.8 a.fr ...tI4,/...„.:////7..../arr,..0/../././n//4/6000S fl47fserm Pmtoction & Communications, Inc. W. #13 036-6701 9 1e630Av Lynnwood, WA (425) 774 - AG F • ' I 6 JJ APR 31998 FIRE ALARM CONTROL PANEL SK 5207 1F41/4cP 1 -Nrec'Lt'k END OF LINE RESISTOR XXXX Ca:3 EXISTING EQUIPMENT XXXX N. 75 CANDELA FIRE HORN STROBE MT-24-IS-VFR 5355 ° SMOKE DETECTOR 2400 acific If erities, 1 rive • -c 3 VIE. • EST 25) 774-9 99 or 1-800-774-90 TE 11 51.8 a.fr ...tI4,/...„.:////7..../arr,..0/../././n//4/6000S fl47fserm Pmtoction & Communications, Inc. W. #13 036-6701 9 1e630Av Lynnwood, WA (425) 774 - AG F • ' I 6 JJ APR 31998