HomeMy WebLinkAboutPP - 831 INDUSTRY DR - OPTIMUM WOODWORKING - PERMITS AND PLANS831 INDUSTRY DR ASSOCIATED PERMITS 99-F-400 TO EXISTING DEVICES TO EXISTING f DEVICES TO EXISTING DEVICES A o -A 1>E. RELOCATE 4 A o- A o- C FROM FACP INITIATING CIRCUIT FROM FACP INDICATING CIRCUIT PARTIAL PLAN SECOND FLOOR SPACE 831 /gyp SCALE: 1/4"=V-0"DD F:\Jobs\Pacific-Gulf\831.dwg Symbols Legend Symbol QTY Description Mounting Manufacturer Part # C 1 Fire Alarm System Control Panel Existing Silent Knight 5207 Control Panel Sc Modules 2 Photo Smoke Detector 4 Square Deep with 3" Round Ring System Sensor 1400 0 Main Circuit Board(Existing) Power Supply/Charger Initiating Zone Module Indicating Circuit Module Masterbox/Line Reversal Miscellaneous Module A Miscellaneous Module B 5207 5 Photo Smoke Detector (Existing) - System Sensor 2400 Ell 3 Horn with 15cd Strobe 2 Gang at 80" to Bottom Wheelock NS -2415W -FR 1 Mini Horn -Strobe (Existing) - Wheelock MIZ-FR Wire Legend Symbol Description Type of Circuit A 2 14 AWG Solid Fire Rated Conventional (IDC) Circuit C 2 14 AWG Solid Fire Rated Audible (NAC) Circuit (Pacific Gulf Space #831) Fire Alarm Systems Battery Calculation Chart Transfer G & H from above to complete Battery Calculations Total Standby AH (G) A B C D E F Device/ Module Model Number Quantity of Device/ Module Standy Current (Amps) Total Standby Current (B x C) Alarm Current (Amps) Total Alarm Current (B x E) Control Panel Sc Modules 0 0 Main Circuit Board(Existing) Power Supply/Charger Initiating Zone Module Indicating Circuit Module Masterbox/Line Reversal Miscellaneous Module A Miscellaneous Module B 5207 1 0.12 0.12 0.7 0.7 0 0 0 0 0 0 `' 0 0 0 0 0 0 Initiating Devices 0 0 Smoke Detector Smoke Detector Smoke Detector Power Supervision Relay 1400 2 0.0001 0.0002 0.001 0.002 2400 6 0.0001 0.0006 0.067 0.402 0 0 0 0 Notification Appliances 0 0 Horn Strobe Horn/Strobe Combination Bell Sync Module Miscellaneous N/A 0 0 N/A 0 0 NS-2415FW 3 N/A 0 0.082 0.246 N/A 0 0 N/A 0 0 0 N/A 0 0 Sum Column for Standby Load (Amps) Multiply by Required Standby Time (24 or 60 hours) x Total Standby AH = Sum Column Multiply by Required Alarm Multiply by Required Alarm 0.1208 G (Amps) = .083) x = .167) x Alarm AH = 24 2.8992 for Alarm Load Time (5 min. Time (10 min. Total 1.35 0.083 0.11205 Transfer G & H from above to complete Battery Calculations Total Standby AH (G) Total Alarm AH (H) Required AH (G + H) Safety Factor (multiply) Total System Ampere -Hours Required 2.8992 0.11205 3.01125 1.2 3.6135 NOTE: Always use a battery with a higher AH rating than required! Battery AH used: 7AH GENERAL NOTES 1. INSTALLATION SHALL BE ACCOMPLISHED IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE AHJ'S, NEC, AND CONTRACT DRAWINGS. 2. WIRE ROUTING IS DIAGRAMMATIC IN NATURE ONLY AND NOT INTENDED FOR ACTUAL CONDUIT ROUTING. 3. ALL CONDUIT} SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ. 4. THE SYSTEM SHALL BE MONITORED BY A UL LISTED MONITORING STATION BEFORE AHJ TEST. 5. VERIFY ALL LOCATIONS OF DEVICES WITH ELECTRICAL/ARCHITECTURAL PLANS. SCALE AND PLACE ALL DEVICES PER ELECTRICAL/ARCHITECTURAL PLANS. 6. FIELD VERIFY WATER FLOW, SPRINKLER, SMOKE DAMPERS AND DUCT DETECTOR LOCATIONS. 7. FIELD VERIFY ALL WIRING LOCATIONS AND REQUIREMENTS FOR HVAC AND FAN CONTROL. 8. SMOKE DETECTORS SHALL NOT BE LOCATED WITHIN 3'-0" OF AIR DIFFUSERS. 9. NFPA 5-3.6.1.3 REQUIRES THAT NO SMOKE DETECTORS ARE TO BE INSTALLED UNTIL AFTER FINAL CONSTRUCTION CLEAN-UP. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO CLEAN-UP MUST BE CLEANED OR REPLACED ACCORDING TO CHAPTER 7 AND WILL BE INVOICED ON A T&M BASIS. 10. FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF TECHNICIANS. 11. ALL CIRCUITS WILL BE PROPERLY TAGGED AND TESTED FOR OPENS, SHORTS, GROUNDS AND PROPER END OF THE LINE RESISTANCE. EACH CIRCUITS METER READING MUST BE DOCUMENTED AND PRESENTED TO FIELD TECHNICIAN UPON ARRIVAL ON SITE FOR CHECKOUT. 12. A SET OF INSTALLATION AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY FIELD TECHNICIANS. 13. AGREEMENT AND CONFIRMATION OF ALL MILESTONE EVENTS WILL BE MADE WITH PROJECT MANAGER. SERVICES MUST BE SCHEDULED WITH PROJECT MANAGER WITH A MINIMUM OF TEN WORKING DAYS NOTICE. 14. NO TAPPING OF SIGNALING OR INITIATING ZONE CIRCUITS ARE ALLOWED. T -TAPPING OF STYLE 4 ADDRESSABLE CIRCUITS IS ALLOWED PROVIDING SPLICE IS PROFESSIONALLY INSTALLED, POLARITY IS OBSERVED, SHIELDS ARE CONTINUOUS AND FREE OF GROUNDS. SHIELDS SHALL BE TERMINATED AT FACP ONLY. ,"CABLE SHIELDS SHALL BE SPLICED TOGETHER AT EVERY JUNCTION BETWEEN THE FIRE ALARM PANEL AND THE LAST DEVICE ON EACH CABLE RUN. SHIELDS AND OTHER FIRE ALARM CONDUCTORS (EXCEPT POWER GROUNDS) SHALL BE INSULATED AND COMPLETELY FREE FROM CONDUIT OR EARTH GROUNDS. SHIELDS WILL BE TIED TO GROUND ONLY AT THE FIRE ALARM PANEL BY THE INSTALLING FIRE ALARM TECHNICIAN." i5. MOUNT AUDIBLE/VISUAL DEVICE BACKBOX AT 80" TO BOTTOM AFF OR 6" BELOW CEILING WHICH EVER IS LOWER. SEE FLOOR PLANS FOR CANDELA RATING OF DEVICE BEING INSTALLED. 16. AS BUILTS ARE REQUIRED AT TIME OF AHJ ACCEPTANCE. PRECISION ALARM NEEDS RED LINE AS BUILTS 2 WEEKS PRIOR TO AHJ TESTS. PCCEPTED Without Comments As Noted In Red [] Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: IVc'‘`) By' 9• T FffLE T'U'KW LA FIRE DEPARTMENT 'Please call: 575-4407 and give this job No. ` F and exact address for shut - ,down or restoration approval. DESCRIPTION Q 0 z FAX (253) 735-0113 W Q ■ J Q C�FrJ CO12: 0 gxQ ELIQ; CO ( SCAM AS NOTED PROJECT NUMBER: 692 DRAWN DESIGNED BY: BY: SEH SEH 1M(gETT7 Al Q E C 0 6 1999 DATE: 12/3/99 SHEET FA -1 rr J