HomeMy WebLinkAboutPP - 887 INDUSTRY DR - CREATIVE ASSEMBLY SYSTEMS - PERMITS AND PLANS887 INDUSTRY DR ASSOCIATED PERMITS 99-F-401 INITIATING CIRCUIT A FROM FACP INDICATING CIRCUIT FROM FACP F V A b >v PARTIAL FLOOR PLAN SPACE 887 (../ SCALE: 1/4"=1'-0"OD c>-- A TO NEXT DEVICE TO NEXT DEVICE c --A Symbols Legend Symbol QTY Description Mounting Manufacturer Part # C 1 Fire Alarm System Control Panel Existing Silent Knight 5207 Control Panel & Modules 1 Photo Smoke Detector 4 Square Deep with 3" Round Ring System Sensor 1400 0 Main Circuit Board(Existing) Power Supply/Charger Initiating Zone Module Indicating Circuit Module Masterbox/Line Reversal Miscellaneous Module A Miscellaneous Module B 4 Photo Smoke Detector (Existing) - System Sensor 2400 0.7 i 1 Heat Detector 135 Fixed Temp (Existing) - Fire Lite HD601 2 Mini Horn -Strobe (Existing) - Wheelock MIZ-FR Wire Legend Symbol Description Type of Circuit A 2 14 AWG Solid Fire Rated Conventional (IDC) Circuit C 2 14 AWG Solid Fire Rated Audible (NAC) Circuit (Pacific Gulf Space #831) Fire Alarm Systems Battery Calculation Chart Transfer G & H from above to complete Battery Calculations Total Standby AH (G) A B C D E F Device/ Module Model Number Quantity of Device/ Module Standy Current (Amps) Total Standby Current (B x C) Alarm Current (Amps) Total Alarm Current (B x E) Control Panel & Modules 0 0 Main Circuit Board(Existing) Power Supply/Charger Initiating Zone Module Indicating Circuit Module Masterbox/Line Reversal Miscellaneous Module A Miscellaneous Module B 5207 1 0.12 0.12 0.7 0.7 0 0 0 0 0 0 0 0 0 0 0 0 Initiating Devices 0 0 Smoke Detector Smoke Detector Smoke Detector Power Supervision Relay 1400 1 0.0001 0.0001 0.001 0.001 2400 4 0.0001 0.0004 0.067 0.268 0 0 0 0 Notification Appliances 0 0 Horn Strobe Horn/Strobe Combination Bell Sync Module Miscellaneous N/A 0 0 N/A 0 0 MIZ-2415FW 2 N/A 0 0.082 0.164 N/A 0 0 N/A 0 0 0 N/A 0 0 Sum Column for Standby Load (Amps) Multiply by Required Standby Time (24 or 60 hours) x Total Standby AH = Sum Column Multiply by Required Alarm Multiply by Required Alarm 0.1205 G (Amps) = .083) x = .167) x Alarm AH = 24 2.892 for Alarm Load Time (5 min. Time (10 min.- Total 1.133 0.083 0.094039 Transfer G & H from above to complete Battery Calculations Total Standby AH (G) Total Alarm AH (H) Required AH (G + H) Safety Factor (multiply) Total System Ampere -Hours Required 2.892 0.094039 2.986039 1.2 3.5832468 NOTE: Always use a battery with a higher AH rating than required! Battery AH used: 7AH GENERAL NOTES 1. INSTALLATION SHALL BE ACCOMPLISHED IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE AHJ'S, NEC, AND CONTRACT DRAWINGS. 2. WIRE ROUTING IS DIAGRAMMATIC IN NATURE ONLY AND NOT INTENDED FOR ACTUAL CONDUIT ROUTING. 3. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ. 4. THE SYSTEM SHALL BE MONITORED BY A UL LISTED MONITORING STATION BEFORE AHJ TEST. 5. VERIFY ALL LOCATIONS OF DEVICES WITH ELECTRICAL/ARCHITECTURAL PLANS. SCALE AND PLACE ALL DEVICES PER ELECTRICAL/ARCHITECTURAL PLANS. 6. FIELD VERIFY WATER FLOW, SPRINKLER, SMOKE DAMPERS AND DUCT DETECTOR LOCATIONS. 7. FIELD VERIFY ALL WIRING LOCATIONS AND REQUIREMENTS FOR HVAC AND FAN CONTROL. 8. SMOKE DETECTORS SHALL NOT BE LOCATED WITHIN 3'-0" OF AIR DIFFUSERS. 9. NFPA 5-3.6.1.3 REQUIRES THAT NO SMOKE DETECTORS ARE TO BE INSTALLED UNTIL AFTER FINAL CONSTRUCTION CLEAN-UP. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO CLEAN-UP MUST BE CLEANED OR REPLACED ACCORDING TO CHAPTER 7 AND WILL BE INVOICED ON A T&M BASIS. 10. FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF TECHNICIANS. 11. ALL CIRCUITS WILL BE PROPERLY TAGGED AND TESTED FOR OPENS, SHORTS, GROUNDS AND PROPER END OF THE LINE RESISTANCE. EACH CIRCUITS METER READING MUST BE DOCUMENTED AND PRESENTE TO FIELD TECHNICIAN UPON ARRIVAL ON SITE FOR CHECKOUT. 12. A SET OF INSTALLATION AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY FIELD TECHNICIANS. 13. AGREEMENT AND CONFIRMATION OF ALL MILESTONE EVENTS WILL BE MADE WITH PROJECT MANAGER. SERVICES MUST BE SCHEDULED WITH PROJECT MANAGER WITH A MINIMUM OF TEN WORKING DAYS NOTICE ACC tPTED DESCRIPTION J v iu Frontage Road North, Suite 9 Pacific, WA. 98047 N FAX (253) 735-0113 AI Without Comments O As Noted In Red Q Per The Attached Letter .lans have been reviewed by The Tukwila Fire tion Bureau for cosfsubject to ermance rth rors ors andt city lit rds. Acceptance ns which do not authorize violations of od rope' rds and ordinances. The responsibility finer. acy of design rests totally .ns, deletions or revisions revstdrawings after te will void eance and will requirea mitta{ of ised drawings for subsequent appnva l. acceptance is subject to field test and inspecti m by ukwila Fire Prevention Bureau. L� These Preve stand miss stand adeq Addit this resu 14. NO TAPPING OF SIGNALING OR INITIATING ZONE CIRCUITS ARE ALLOWED. T -TAPPING OF STYLE 4 ADDRESSABLE CIRCUITS IS ALLOWED PROVIDING SPLICE IS PROFESSIONALLY INSTALLED, POLARITY IS OBSERVED, SHIELDS ARE CONTINUOUS AND FREE OF GROUNDS. SHIELDS SHALL BE TERMINATED AT FACP ONLY. "CABLE SHIELDS SHALL BE SPLICED TOGETHER AT EVERY JUNCTION BETWEEN THE FIRE ALARM PANEL AND THE LAST DEVICE ON EACH CABLE RUN. SHIELDS AND OTHER FIRE ALARM CONDUCTORS (EXCEPT POWER GROUNDS) SHALL BE INSULATED AND COMPLETELY FREE FROM CONDUIT OR EARTH GROUNDS. SHIELDS WILL BE TIED TO GROUND ONLY AT THE FIRE ALARM PANEL BY THE INSTALLING FIRE ALARM TECHNICIAN." 15. MOUNT AUDIBLE/VISUAL DEVICE BACKBOX AT 80" TO BOTTOM AFF OR 6" BELOW CEILING WHICH EVER IS LOWER. SEE FLOOR PLANS FOR CANDELA RATING OF DEVICE BEING INSTALLED. 16. AS BUILTS ARE REQUIRED AT TIME OF AHJ ACCEPTANCE. PRECISION ALARM NEEDS RED LINE AS BUILTS 2 WEEKS PRIOR TO AHJ TESTS. Fina The Dat W IL D Q �J3 0 Q Fr< Y. r§ - z3 Ikt• (1) TUKWILA riRE DEP iARTMEM Please call: 575-4407 and give this job and exact address for shr t - down or restoration app \ 1' SCALE: AS NOTED PROJECT NUMBER: 692 DRAWN BY: SEH DESIGNED BY: SEH 0 DATE: 12/3/99 DEC 0-6 1919 SHEET