2/17/2010
Tukwila Fire Martial's Office
FIS
This is a submittal for the replacement of two rate of rise heat detectors in Seattle Favorites
to fixed temp heat detectors. We will also add two heat detectors in the freezer. The two
freezer detectors will be tied into the existing heat detector circuit. The job site address is
941 Industry DR Tukwila WA 98188. There are no changes to the audible or visual circuit so
the power calculations will not change. The system will be installed per NFPA72 and Tukwila
Fire Code.
If you have any questions at all, please feel free to call me.
Sincerely,
Joe Peterson
206-575-1962
FROULA ALARM SYSTEMS, INC.
NOTICE
A completed, signed, Tukwila
Fire Department Pre-test
Certificate must be presented
to the Inspector prior to
commencement of Acceptance
Testing of any Fire Alarm
and Detection Systems.
Failure of test will result
in a Re -inspection Feeand
termination of the testing.
A EPTED-
IR^ V itho3 t Comments
As Nt)ted in Red
1 Per .i`h' Attacked Letter
pans have red by The Tukwila Fire
.'7' = �e.ct1 t' ureau c. ;nfc rnarif.~e with current City
Accept6He is (i.:,0i,ect to errors and
r ;t �; ; . ations of
'rVrtiC� t Liu r � '.�. ..�:; _., i7i {. adopted
\
r nd... ! i` tai r`r)�s °: ii. �9. 1 ' 4 :'sponsibility for the
the designer..
A"d:bisn_, re. s , :.. these drawings after
atis date +r vo,k l cr)s.;L u.s%wiii! requlreea ' • ^
Or wf, � fi subsequent app ° . • !_)F
cop.,at; :e is subaect to 'field test and inspecti6p[iy 2010
1 l : fUka1iF Prevention f,-it»ireaU.
ruk la Fire
Date: "2- 1- / 0 Ely-:..4E�..si
cc
861 Industry Drive • Tukwila WA 98188-3411 • Phone: 206-575-1962 ♦ Fax: 206-575-8168
Email: froulaafrouiaaiarms.com • Website: www.froulaalarrns.com
Froula Alarm Systems, Inc., 861 Industry Dr., Tukwila, WA 98188
g
r
o
2 Cl)
c=mo
v� N
3.o =.a
F S a
i91
a
ar2
Al sienbe .91/81
fir' l—
Id m
JL
cis W®o
co -
co
ti
OPEN WAREHOUSE
OPEN OFFICE
OFFICE
OFFICE
BATHROOM
LOBBY 941
OPEN WAREHOUSE
TWO NEW HEAT DETECTORS IN FRFF7FR TIED INTO
EXISTING DEVICE ABOVE FREEZER
(H1
NEW FREEZER
BATH ROOM
OPEN OFFICE
EXISTING DEVICE - RELOCATED
LOBBY 943
NOTES:
1) ALL WORK TO CONFORM TO NFPA 72 AND NEC STANDARDS
2) WALL MOUNT HORN STROBES AND STROBES TO BE MOUNTED 80"-96" AFF
OR 6" BELOW CEILING WHICHEVER IS LOWER.
3) PULL STATIONS TO BE MOUNTED:
A) 48" - 53" AFF
B) WITHIN 5' OF THE DOOR.
4) FIRE ALARM CONTROL PANEL TO BE ON DEDICATED CIRCUIT
5) WIRING METHOD TO BE OPEN CABLE UNLESS BELOW 7' AND EXPOSED,
THEN IT WILL BE CONTAINED WITHIN CONDUIT.
6) SMOKE DETECTORS TO BE INSTALLED:
A) MORE THAN 36" FROM ANY HVAC DIFFUSER
B) NOT IN CLOSE PROXIMITY TO FLUORESCENT LIGHTING
C) AT LEAST 6" DOWN FROM PEAK IN SLOPED CEILING
7) ALL JUNCTION BOXES, MUD RINGS AND BOX COVERS TO BE PAINTED RED
(INSIDE AND OUT).
8) EXTERIOR HORN STROBES TO BE MOUNTED IN THE TOP 2/3 OF THE
BUILDING STRUCTURE FACING THE ANTICIPATED FIRE DEPARTMENT ACCESS
ROAD.
9) BATTERY CALCULATION ARE UNCHANGED. ALL NOTIFICATION
APPLIANCES ARE EXISTING AND ADDITIONAL HEAT DETECTORS ARE ZERO
LOAD DEVICES.
10) SEAL PENETRATIONS AND PIPE INTO FREEZER TO PREVENT
CONDENSATION.
Equipment Legend*
Symbol
Quantity
Part Number
Description
Back Box
1
BY OTHERS
Existing Fire Alarm Control Panel
Included
3Tf]'.
0
N/A
Fire Alar Power Supply
Included
O1
N/A
Existing Heat Detector
4" Square
O0
N/A
Photoelectric Smoke Detector
4" Square
2
302-ET184
Probe Heat Detector
4" Square
o
270ASPO
Existing Manual Pull Station
4" Square
F
®
1
MT24LSM
Existing Hom Strobe
4" Square
0
N/A
Strobe
4" Square
to.
2
0
N/A
Outdoor Hom Strobe
Included
0
N/A
CEILING MOUNT HORN STROBE
4" Square
co
0
N/A
CEILING MOUNT STROBE
4" Square
0
BY OTHERS
LOW AIR SWITCH
4" Square
LA
W
0
BY OTHER
WATER FLOW SWITH
4" Square
0
BY OTHERS
TAMPER SWITCH
4" Square
T
'NOT ALL DEVICES SHOWN ON LEGEND ARE USED IN THIS PROJECT
WIRE LEGEND
A- 18 GAUGE 2 CONDUCTOR 'FPLP'
B- 14 GAUGE 2 CONDUCTOR 'FPLP'
C- 18 GAUGE 4 CONDUCTOR 'FPLP'
D- 14 GAUGE 4 CONDUCTOR 'FPLP'
121' Without Comments
O As Noted in Red
O Per The Attached Letter
These plans have been reviewed by The Tukwila Fire
Prevention Bureau for conformance with current City
standards. Acceptance is subject to errors and
omissions which do not iii..ithorize violations of adopted
standards and oruin.i;c<cs. The responsibility for:the
adequ8cy of design Pf.:2:1S totally with the designer.
Additions, deletions oi..Rvisions to these drawings after
this date will vold this .. c:cepi ,,nce :rid will require a
resubmittal of revisal drawings for _ ibsecit.!ent approval.
Final acceptance is subject to held test and Inspection by
The Tukwila Fire Prevention Bureau,
Date: 1-4--! ( By: 51
NOTICE
A completed, signed, Tukwila
Fire Department Pre-test
Certificate must be presented
to the Inspector prior to
commencement of Acceptance
Testing of any Fire Alarm
and Detection Systems.
Failure of test will result
in a Re -inspection Fee and
termination of the testir>p,
TUKWILA FIRE DEPARTMENT
Please call 206-575-4437 and
give this Fire Permit No.
and exact adds ss for shut-
clown
hutclue n or restoration approval.
PAID
JAN 10 2012
TUKWILA FIRE
Froula Alarm Systems, Inc.
861 Industry Drive
Tukwila, WA 98188
206-575-1962
DESIGNER OF RECORD
Kristopher Conner
NICET III
69311
a)
MINIM
L.. (x)
a) 0 co
-rm.: as No cO
> withs
co
(I)
Chi �►
c0 c45
vr- Faxma
0)
E
DATES:
SUBMITTAL
REVISION
SHEET TITLE
FIRE ALARM
PLAN
SHEET NUMBER
FA -1