Loading...
HomeMy WebLinkAboutPP - 941 INDUSTRY DR - COWAY USA INC. - PERMITS AND PLANS941 INDUSTRY DR ASSOCIATED PERMITS 12-F-007 10-F-034 • funWHA FIRE DEPARTOAti*1 Please call: 575.4147,' and give this job No. /o -F -O3`1 and exact address for shut. Froula Alarm Systems, Inc.""" or ►astoration apnrn 2/17/2010 Tukwila Fire Martial's Office FIS This is a submittal for the replacement of two rate of rise heat detectors in Seattle Favorites to fixed temp heat detectors. We will also add two heat detectors in the freezer. The two freezer detectors will be tied into the existing heat detector circuit. The job site address is 941 Industry DR Tukwila WA 98188. There are no changes to the audible or visual circuit so the power calculations will not change. The system will be installed per NFPA72 and Tukwila Fire Code. If you have any questions at all, please feel free to call me. Sincerely, Joe Peterson 206-575-1962 FROULA ALARM SYSTEMS, INC. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Feeand termination of the testing. A EPTED- IR^ V itho3 t Comments As Nt)ted in Red 1 Per .i`h' Attacked Letter pans have red by The Tukwila Fire .'7' = �e.ct1 t' ureau c. ;nfc rnarif.~e with current City Accept6He is (i.:,0i,ect to errors and r ;t �; ; . ations of 'rVrtiC� t Liu r � '.�. ..�:; _., i7i {. adopted \ r nd... ! i` tai r`r)�s °: ii. �9. 1 ' 4 :'sponsibility for the the designer.. A"d:bisn_, re. s , :.. these drawings after atis date +r vo,k l cr)s.;L u.s%wiii! requlreea ' • ^ Or wf, � fi subsequent app ° . • !_)F cop.,at; :e is subaect to 'field test and inspecti6p[iy 2010 1 l : fUka1iF Prevention f,-it»ireaU. ruk la Fire Date: "2- 1- / 0 Ely-:..4E�..si cc 861 Industry Drive • Tukwila WA 98188-3411 • Phone: 206-575-1962 ♦ Fax: 206-575-8168 Email: froulaafrouiaaiarms.com • Website: www.froulaalarrns.com Froula Alarm Systems, Inc., 861 Industry Dr., Tukwila, WA 98188 g r o 2 Cl) c=mo v� N 3.o =.a F S a i91 a ar2 Al sienbe .91/81 fir' l— Id m JL cis W®o co - co ti OPEN WAREHOUSE OPEN OFFICE OFFICE OFFICE BATHROOM LOBBY 941 OPEN WAREHOUSE TWO NEW HEAT DETECTORS IN FRFF7FR TIED INTO EXISTING DEVICE ABOVE FREEZER (H1 NEW FREEZER BATH ROOM OPEN OFFICE EXISTING DEVICE - RELOCATED LOBBY 943 NOTES: 1) ALL WORK TO CONFORM TO NFPA 72 AND NEC STANDARDS 2) WALL MOUNT HORN STROBES AND STROBES TO BE MOUNTED 80"-96" AFF OR 6" BELOW CEILING WHICHEVER IS LOWER. 3) PULL STATIONS TO BE MOUNTED: A) 48" - 53" AFF B) WITHIN 5' OF THE DOOR. 4) FIRE ALARM CONTROL PANEL TO BE ON DEDICATED CIRCUIT 5) WIRING METHOD TO BE OPEN CABLE UNLESS BELOW 7' AND EXPOSED, THEN IT WILL BE CONTAINED WITHIN CONDUIT. 6) SMOKE DETECTORS TO BE INSTALLED: A) MORE THAN 36" FROM ANY HVAC DIFFUSER B) NOT IN CLOSE PROXIMITY TO FLUORESCENT LIGHTING C) AT LEAST 6" DOWN FROM PEAK IN SLOPED CEILING 7) ALL JUNCTION BOXES, MUD RINGS AND BOX COVERS TO BE PAINTED RED (INSIDE AND OUT). 8) EXTERIOR HORN STROBES TO BE MOUNTED IN THE TOP 2/3 OF THE BUILDING STRUCTURE FACING THE ANTICIPATED FIRE DEPARTMENT ACCESS ROAD. 9) BATTERY CALCULATION ARE UNCHANGED. ALL NOTIFICATION APPLIANCES ARE EXISTING AND ADDITIONAL HEAT DETECTORS ARE ZERO LOAD DEVICES. 10) SEAL PENETRATIONS AND PIPE INTO FREEZER TO PREVENT CONDENSATION. Equipment Legend* Symbol Quantity Part Number Description Back Box 1 BY OTHERS Existing Fire Alarm Control Panel Included 3Tf]'. 0 N/A Fire Alar Power Supply Included O1 N/A Existing Heat Detector 4" Square O0 N/A Photoelectric Smoke Detector 4" Square 2 302-ET184 Probe Heat Detector 4" Square o 270ASPO Existing Manual Pull Station 4" Square F ® 1 MT24LSM Existing Hom Strobe 4" Square 0 N/A Strobe 4" Square to. 2 0 N/A Outdoor Hom Strobe Included 0 N/A CEILING MOUNT HORN STROBE 4" Square co 0 N/A CEILING MOUNT STROBE 4" Square 0 BY OTHERS LOW AIR SWITCH 4" Square LA W 0 BY OTHER WATER FLOW SWITH 4" Square 0 BY OTHERS TAMPER SWITCH 4" Square T 'NOT ALL DEVICES SHOWN ON LEGEND ARE USED IN THIS PROJECT WIRE LEGEND A- 18 GAUGE 2 CONDUCTOR 'FPLP' B- 14 GAUGE 2 CONDUCTOR 'FPLP' C- 18 GAUGE 4 CONDUCTOR 'FPLP' D- 14 GAUGE 4 CONDUCTOR 'FPLP' 121' Without Comments O As Noted in Red O Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not iii..ithorize violations of adopted standards and oruin.i;c<cs. The responsibility for:the adequ8cy of design Pf.:2:1S totally with the designer. Additions, deletions oi..Rvisions to these drawings after this date will vold this .. c:cepi ,,nce :rid will require a resubmittal of revisal drawings for _ ibsecit.!ent approval. Final acceptance is subject to held test and Inspection by The Tukwila Fire Prevention Bureau, Date: 1-4--! ( By: 51 NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testir>p, TUKWILA FIRE DEPARTMENT Please call 206-575-4437 and give this Fire Permit No. and exact adds ss for shut- clown hutclue n or restoration approval. PAID JAN 10 2012 TUKWILA FIRE Froula Alarm Systems, Inc. 861 Industry Drive Tukwila, WA 98188 206-575-1962 DESIGNER OF RECORD Kristopher Conner NICET III 69311 a) MINIM L.. (x) a) 0 co -rm.: as No cO > withs co (I) Chi �► c0 c45 vr- Faxma 0) E DATES: SUBMITTAL REVISION SHEET TITLE FIRE ALARM PLAN SHEET NUMBER FA -1