Loading...
HomeMy WebLinkAboutPP - 1025 INDUSTRY DR - JOES GARAGE - PERMITS AND PLANS1025 INDUSTRY DR ASSOCIATED PERMITS 16-F-040 09-5-216 OS -5-159 08-F-396 08-5-025 4576(2 JOE'S GARAGE JOES GARAGE TUKWILA COMMERCE CENTER SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 9202470130 Site Address: 1025 Industry Drive Bldg. 33-S. Sprinkler Riser suite Number: Floor: Tenant Name: Tukwila Commerce Center New Tenant? ❑- Yes El- No Property Owner's Name:Icon Tukwila Owner Mailing Address: 1025 Industry Drive Tukwila WA 98188 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Sheramie Odell Day Telephone: 206.622.6545 ext.327 Company Name: Guardian Security Marling Address:1501 Kentucky St. Bellingham, WA 98229 sodellnn uardiansecurit .com City E-mail Address: Vg y Fax Number: State Zip Contractor's City of Tukwila Business License number: GUARDSS233K5 Total number of new/relocated devices or sprinkler heads: 3 Valuation of Project (contractor's bid price): $ 1,000 Scope of Work (please provide detailed information): Install (1) AES7706-ULF, install (1) 2 -wire p/e smoke, install (1) pull station, single action, red. Location of work: sprinkler/riser room. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN _' OR A ,• ORIZED AGENT: Signature: Date: 3/3/16 Print Name: Sheramie Odell Day Telephone: 206.622.6545 ext. 327 Plan Permit App.doc 8/22/14 TFD FP Form 8 iso GUARDIAN SECURITY Seattle - Tacoma - Poulsbo - Bellingham 03/03/2016 City of Tukwila Fire Department Development Services 444 Andover Park East Tukwila, WA 98188 RE: Installing AES7706-ULF Guardian Security Systems would like to install action -red (1) AES Radio-AES7706-ULF at the Sincerely, NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of ;acceptance Testing of any Fire Alarm and i~% :.enoyl Svstr ms. Failure of :est result in a Re -inspection Fee and termination of the testing (1) 2 wire pie smoke, (1) pull station -single following address: 1501 Kentucky St Bellingham, WA 98229 Tel: 208.622.6545 ext 327 Tukwila Commerce Center Bklg 33. -South Riser Tu Sheramie Odell Administrative/Permits Specialists sodell@a,guardiansecurity,comn 206.622.6545 ext. 327 Enclosure TUKWILA FIRE DEPARTMENT Pose ca 206-575-4407 and l give this o ,Pet tit No. :end exact idctnss for shut- down hutdown or restor4ion approval. ACCEPTED CI Without Comments As f':'oreci in Reg Ci Pe! 'The Attached Letter Fans have bee! ;Aewed by The Tukwila Fire n . 7-Drrnance with current City r. cr s; Iar'ei* to errors and ,solations of adopted ancr t: !'r:soonsibliltyJ for the ; of rie, :., ; vv t the designer, deleticr, F.. a .. co mese drawings after tri s, will void and will require a restionlittai of reviser, ,x L» . .a ;subsequent approval. Finaacceptance s The rukwila Fire Date: '+c`',o test and Inspection by 1 Q AI S'6►4.1otiS re,,,;,rw1 q'i G it e xleriov e11 i S. Ei ►, . Fvor bs.-4 Sk.4-eto.rol- 1 s &I a ati elC14s '1k E FA o o4d;tai,.J c;vv ¥i✓/loom/At-'AID hytieik 6141 . MAI? —4 2016 TUKWILA FIRE ZTte 5' '4v — 12/30/2009 16:59 FAX 2537350113 FIRE SYSTEMS WEST Fire Systems West, Inc. 'I001 219 Frontage Road North, Suite B • Pacific, Washington 98047-I023 • Phone (253) 833-1248 • Fax (253) 735-0113 December 30, 2009 Tukwila Fire Department 6200 Southcenter Blvd. Tukwila, WA. FILE Attention: Al Metzler Fax: (206) 575-4439 Reference: Correction on sprinkler system. 1025 Industry , Tukwila, WA. Narrative: On December 30, 2009 Traverse Bay Convection has hired Fire Systems West to cap sprinkler head in cooler due to removing cooler. Sincerely, urk ice Manager 1 U11 WIlA FIRE DEPART1UEN1 Please call: 575.410% and give this job jrni exact address for shut' >wn or restoration appy v Accepted By: Shut Down number: Title: Date: Phone: Protection & Communications, Inc. iz v sp-- coin -4 19630 40th Avenue West, Suite B • Lynnwood, Washington 98036 • (425) 774-9099 • FAX (425) 774-6317 pro-comm-online.com D ACCEPTED I Without Comments As Noted In Red Per The Attached Letter 1 nese plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted stanaaras and orainances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings atter this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bu Date: Bye o/w NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termir-ltion of the testing.. PAID JUL 2 8 2008 Tukwila Fire 44- 241 IUKWItA FIRE DEPAR1i ali Please call: 575.4407 and give this job and exact address for shut. Town or restoration approval, It 2[1:44___ :ro woo•euiluo-wwoo-aid L 6E9-bLL (9Zb) XVd • 6606-17/1 (9617) • 9E086 uo36ulyseM 'poomuuA1 • 9 a nS '3saM anuaAv 140170696 L •3u1 'suopeajunwwoo +g uopoesoad 1,•11INI.,001,•=11111111,—Ir--.1. —i—i—i—,—i—i---=—i—i—i—i—i —,r--,_._., —, —, —, ----,—,---,—,—,— _._,..-7-- 1--.t_—_` __— ___. FILE 6" EXISTING BUILDING PARTIAL FIRE SPRINKLER PLAN SCALE: NONE 1 VICINTIY MAP SCOPE OF WORK SCALE: NONE INSTALL 1 -VIKING 286° F DRY PENDENT IN FREEZER PAID '- - 2008 Tukwila Fire CONTRACT NAME: Traverse Bay Confection 1025 Industry Drive Tukwila, WA 98188 CONTRACT WITH: Traverse Bay Confection 1025 Industry Drive Tukwila, WA 98188 206-722-0196 Rich 256547 /5z Fire Systems West 219 Frontage Road North, Suite B Pacific, WA. 98047` (253) 833-1248 Fax: (253) 735-0113 ' WA CL #FIRESWI 14081 SOLD BY: JIM TURK INSTALLED BY: FITTER DESIGNER DATE JOB NO. SHEET DAWNIELLE HALLSTEAD 1-25-2008 2-12-6100 1 OF 1 1 ACCEPTED Without Comments As Noted In Red Per The Attached Letter r nese plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subi,ct to errors and omissions which do not authorize violations of adopted standaras and orainances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings atter this date will void this.acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: D -- i — Og By: I UKWILA FIRE DEPARTMENT Please call: 575.4407 and give thls job No.OB 'S- ®),,r and exact address for shuts sown or restcration?eporovol: Because of increased demand our inspectors' schedules are booked 3-7 days ahead. Therefore, you will need to call 206-575-4407 or email fireinsprequest Iitukwial.W .uN schedule your inspkdons a fninimum of 48 hours in advance of the date you want an inspection. f=iLE COPY EXIST..6. FIRE SPRINKLER PLAN SCALE: 118"=1'-0" ADD PENDENT SPRINKLER FROM EXISTING LINE ABOVE EXIST NO NEW FIRE SPRINKLER WORK SCOPE OF WORK 1. INSTALLING SPRINKLERS TO THE NEW PROCESSING AREA AND BATHROOM. EXCLUSIONS 1. ELECTRICAL OF ANY TYPE. 2. RELOCATING EXISTING SPRINKLER PIPE FOR NEW WORK OF OTHER TRADES. 3. STRUCTURAL VERIFICATION IF REQUIRED. 4. ABATEMENT OF ANY TYPE. 5. BACKFLOW PREVENTOER UPGRADES. 6. PAINTING OF ANY TYPE. 7. OFF HOURS. 8. TAX. DESIGN CRITERIA THROUGHOUT: PER NFPA #13 (1999 EDITION) AND TUKWILA FIRE DEPARTMENT HAZARD: ORDINARY SYMBOL LEGEND OE - EXISTING SPRINKLER HEAD. R - SPRINKLER HEAD TO BE RELOCATED. OA - SPRINKLER HEAD TO BE ADDED. P - SPRINKLER HEAD TO BE PLUGGED. /- -/-/-- SPRINKLER PIPE TO BE DEMOLISHED. - - - -- EXISTING SPRINKLER PIPE. NEW SPRINKLER PIPE. FAL TUKWILA FIRE DEPARTMENT Please call: 575-4407 and give this job and exact address for shut- down or restoration approval. Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire } Prevention Bureau for conformance with current city standards. Accept :r,c-;: is subjra t to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design re;:;s totally with the designer. Additions, deletions tions or revisions to the drawings after this date will void this,.acceptance and will require a resubmittal of revised drawings for subsequerit approval. Final acceptance is subject to field test and inspection by The Tukwila Fire PreventionvetiBureau. CONTRACT NAME: TRAVERSE BAY CONFECT. \Q2 CONTRACT WITH: 5028 WILSON AVENUE SOUTH T VERSE BAY CF1 • TUKWILA, WA 98118 (206) 725-0099 RICHARD ANDERSON HANGER LEGEND SPRINKLER LEGEND SPRINKLER HEADS REVISIONS GENERAL NOTES DESIGN CRITERIA AND NOTES SPKR SPRINKLERS THRDS ORIFICE SIZES AND TYPE SYM TYPE MFG MODEL ORIFICE THREAD TEMP FINISH CANOPY QTY MK DATE BY PENDENT SIZE TEE PENDENT TYCO CHROME 1/2" 3/8" 7/16" 1/2" SPRAY APPROVALS REQUIRED: DISTRIBUTION: TEMP RATING 0 155° TUKWILA FIRE DEPT. TUKWILA FIRE DEPT. OWNER/ARCHITECT OWNER/ARCHITECT FIRE SYSTEMS WEST 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UNDERWRITERS APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISER & DIMENSIONS SHOWN THUSLY (1'-6")WHICH ARE END TO END. 3. EARTHQUAKBRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA #13. 4. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA #13. 5. PIPING SHALL BE IN ACCORDANCE WITH NFPA #13. 6 JOINING OF PIPE AND FITTINGS, THREADED AND WELDED SHALL BE IN ACCORDANCE WITH NFPA#13. 7. OWNER TO PROVIDE ADDAQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY WET PIPE SPRINKLER SYSTEM. 8. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER OR HIS STRUCTURAL REPRESENTITIVE. 1. ALL NEW PIPE TO BE IMPORT SCHEDULE 40. 2. ALL NEW FITTINGS TO BE IMPORT CAST IRON. 3. ALL SPRINKLERS IN G.W.B. CEILINGS TO HAVE 1" X 1/2" ADJUSTABLE DROP NIPPLES. Fire 219 Frontage Road North, Suite B Pacific, WA. 98047 (253) 833-1248 Fax: (253) 735-0113 WA CL #FIRESWI 14081 SOLD BY: DENNIS SMITH INSTALLED BY: / / DESIGNER DATE JOB NO. SHEET JIM STEWART AUGUST 8, 2005 1-02-11-9317 1025 INDUSTRY DR ASSOCIATED PERMITS 16-F-040 D16-0348 D17-0098 M17-0051 INSPE ION NUMBER INSPECTION RECORD Retain a copy with permit A4 -034i1 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Lif--5 67m -4--6-,c Type of spection: F-7,4-&----f-7,./fi-e--__ Address:// Suite #: 162 <n OLS. Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: — f(c16- ,./ App - Ptri p/,J62 7//' �, �� f' 67 t 77'"j r /3'z_67 4p,i vi i Occupancy Type: I — /,f4777 — / Fila---- — 5 tJ Goiz-s - m�,., T* '1 F ---w Sp as `~ �►k- no - iPir7410, rJ . Ptri Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: g2,v1 5--4. Date: --e.," 74,m- Hrs.: i $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Project,: sG7 ��� �Ty\pe of Inspection: K—/...'- Address: Suite #: 0Q -IS-- //•-) Oi� t1� Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: (6 I/1/F) Np(�ovr-'D Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: - Pre -Fire: Permits: Occupancy Type: 1 Inspector: 47,, 6-4- Date: /u 11 K Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit lep-c- logo PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:6)7714141'GQ atA, ��ii Type of Insp�CtiA. Address: orle� Suite #: /0-74-- l yeicesA7 33 Contact Pers n: Special Instructions: Phone No.: ,Approved per applicable codes. Corrections required prior to approval. COMMENTS: /Ns7sr6/ Net.) 4171, P w% i.�i,+./ AL --5 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: oz, . f_r-� Date: 7/6/16 Hrs.: /. a i / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 1