Loading...
HomeMy WebLinkAboutPP - 1033 INDUSTRY DR - SUNLIGHT SEWING - PERMITS AND PLANS1033 INDUSTRY DR ASSOCIATED PERMITS 03-5-056 0 0 EXISTING OFFICE 8 6-4 0 0 aka,'— iii EXISTING OFFICE 1Y4 - �t -1Y4 114 `-11/4 r t— — -1.14 _ _ 1114_ P 113R) r -e- 0--- 1 Q)* EXISTIN� 0 EXISTING 0 EXISTING —4 114 NEW WALL lam R 11/4 R / 1- 1/4_ -� 8-0 CEILING 0 0 I EXISTING OFFICE° 0 1 REFLECTED CEILING/PIR 1(4” = 1' \1G PLAN NORTH EXISTING BLDG -SPRINKLERED GENERAL NOTES 1 ALL MATERIAL AND INSTALLATION PER NFPA 13 2 ALL REQUIRED ACCEPTANCE TESTING SHALL BE PERFORMED BY THE INSTALLER IN ACCORDANCE WITH NFPAI 3 AND THE AUTHORITY HAVING JURISDICTION 3 ALL NEW PIPING IS ALLIED SCHED 40 WITH C I FITTINGS 4 ALL ARMOVERS OVER 2' ARE TO BE HUNG PER NFPA 13 5 EXISTING COMBUSTIBLE AREA ABOVE CEILING GRID PROTECTED BY EXISTING UPRIGHTS SPRINKLER LEGEND. • - EXISTING PENDENT HEAD IN 1x1 BUSHED OUTLET • R- RELOCATED PENDENT HEAD QTY= 6 • P- PLUGGED PENDENT HEAD OTY= 3 PIPING LEGEND. ----- EXISTING PIPE - NEW PIPE ;AREA OF, -WOW; GST 20 ------tom VIED JOISTS 3/8' HANGER #16 N.T.S TUKWILA FIRE DEPARTM ('1 Please call 575 4407 and give this job No OILS 05(o and exact address for shut down or restoration aodroval ACE HA AGER RING ACCEPTED Without Comments As Noted In Red Per Tne Attached Letter !These pins have been rev eyed by The Tukm'a Fire I Preven-,on Bur Lr cc ., -r for cr torm3r ice Y,"rh cut rent city standards A-ccp'orce is s.,� act to en FIs and omissto^s which do not au thortzc v olationis of adcrted standards and crdlnances The reapors,-,tt y'For toe dequacy cf design rests to -tatty ►,k,tn tete desl,ne- f ;Add tons odiattons or rev'=io1c ho these a wirig3 of r r tots date w it acid this accepterce and d' !II ragLYte a i? a resubmittal of revised drawings for subsequent af,pro'al Final acceptance is subject to field test and inspection oy The Tukwila Fire Prevention Bureau Date f31 z5(e3 By r -s7 FIRE PROTECTION SYSTEMS, INC. 23220 MAPLE VALLEY/BLACK DIAMOND RD S E. - MAPLE VALLEY WA 98038 SPRINKLERS LEGEND SYM 0 TYPE HEAD UPRIGHT ON LINE MODEL MAKE SIZE TEMP FINISH ESCUTCI~EON OTY �-+- EARTHOUAKE BRACE --0— FLOW RISER -- — FLEXIBLE COUPLING �-- FLOW DROP RIGID COUPLING O UPRIGHT ON 1 STUB UP -Is— REDUCING COUPLING 0 • PENDENT ON LINE FLEXIBLE COUPLING de CAP t PIPE TO BOTTOM OF DECK PENDENT ON 1" DROP SCREWED CAP UPRIGHT do PENDENT ON 1" DROP DRY PENDENT PLUG WELD P'ECE NUMBER HANGER LEGEND 11 - U -HOOK W/2 NO16x2" DRIVE SCREWS FGA 1'-2" PIPE OR LAG SCREW PER NFPA #13 FOR 2-1/2` AND LARGER PPE #5 - EYE SOCKET W/3/8" x 2-1/2' LAG SCFEw A T RCD c PIPE RING X110 - EYE ROD W/ LAG SCREW PER NPA #13 & PIPE RING /12 - TOP BEAM CLAMP A T ROD & PPE R NG SYSTEM DESIGN CPITERtA PER NFPA 13-D LIGHT HAZARD --�— HANGER LOCATION SIDE WALL s� HYDRAULIC PEFERENCE POINT TOTAL SPRINKLERS THIS SHEET _L_ �-- t PPE TO FIs+SPED FLOOR • MAR 0- w 2 4 2003 SUITE 3-D 425-432-4401 CONTR LIC ACEFIPS147P1 i`°, PROJECT TUKWILLA COMMERCE CTR TI 1033 INDUSTRY DRIVE TUKWILLA, WA 98188 CONTRACT HATH LINN DOUGLAS PO BOX 5819 KENT, TA 98064 DRWG TITLE FIRE SPRINKLER PLANS DATE 3-14-03 DRAWN BY MM REVISED SCALE AS NOTED CONTR # 03-1844 APPROVALS BY KING COUNTY 1 OF VIS !A& AUTOMATIC SPRIMKL' R CO. SEATTLE, WASH. The drawings affixed hereto have been reviewed and accepted as .meeting or exceeding ` minimum requirements .of the City of Tukwila. Fire Dept., Bureau of Fire Prevention. Additions or..;revisions to these drawings after this date shall reviewed, cconstrued -as being app. CITY OF TU ILA BUREAU OF FIRE PREVENTION WASHINGTON SURVEYING & RATING BUREAU SEATTLE, WASH. As meeting requirements of this Bureau for classification as sprmklered; however, system changes or additions as recommended on the attached sheets) will result in improved rates. Acceptance applies to plans as submitted and for construction and occupancy shown thereon. Finished installation subject to inspection for final acceptance Alt comments, approvals and acceptances relate exclusively to relative ' effect of various conditions anon fire insurance rates. , They are not to be construed as bearing in any way upon the question of whether "due • care" has been exercised with rrespect to possible recognized lt abihtyhazarysfor personalnal Injury or damage to property. result in loss still exist. PORTLAND NO. HEADS AUTOMATIC SPRINKLER CO. SEATTLE. WASHINGTON 3434.1ST AVE. SO. MA 2.4656 1JC'J ski'' L uk: ! c DRAWN SY 1