Loading...
HomeMy WebLinkAboutPP - 1050 INDUSTRY DR - ALEXEEV CONSTRUCTION - PERMITS AND PLANS1050 INDUSTRY DR ASSOCIATED PERMITS 99-F-332 95-F-226 Protection & Communications, Inc. 19630 40th Avenue West, Suite B • Lynnwood, Washington 98036-6701 • (425) 774-9099 • FAX (425) 7746317 IRS @dilitiONS FORM DATE: 9/14/99 A B C D E Pacific Gulf Phase V, BLDG. JOB NAME: 34 Current Draw Worksheet Device Number of Devices Current per Device Standby Current Alarm Current 5207 Fire Control /Communicator 1 Standby: 120mA Alarm: 400mA 120 400 5210 Zone Expander 0 Standby: 40mA Alarm: 40mA 0 0 5220 Direct Connect Module 0 Standby: 50mA Alarm: 50mA 0 0 5230 Remote Annunciator (7 max.) 0 Standby: 60mA Alarm: 120mA 0 0 5205 Dialer 0 Standby: 10mA Alarm: 100mA 0 0 7181 Zone Converter 0 Standby: 35mA Alarm: 65mA 0 0 Current Subtotals (in mA) 1 120 400 Smoke Detectors 1' BRK-2400 Smoke detector 48 Standby:.120mA Alarm: 70mA 5.76 3360 Racal BeamMaster Beam Smoke Detector w/ remote station 0 Standby: 4.7mA Alarm: 29.7mA 0 0 Hochiki HSC -221 L Heat detector w/ L.E.D. Base 8 Standby: OmA Alarm: 44mA 0 352 Current Subtotals (in mA) 5.76 3712 Notification Devices 1' 7874.00 Total Current ratings coverted to amperes (X .001) 0.126 7.874 Wheelock MIZ-24WM Minihorn/Strobe 18 Alarm: 127mA � s „ �`;`� ,�. �. � ,� �, , 2286 Amseco Bell 1s; Alarm: 63mA r � �. � 63 Wheelock WS3T-24FR Strobe 1 115mA mA Alarm: _- 115Alarm: Wheelock Strobe only 9 Alarm: 127mA 0 1143 WH 127809 NS -2475W -FR 75CD Horn Strobe 1 Alarm: 155mA '" r 155 Current Subtotals (in mA) 3762 Additional Devices 1' 7874.00 Total Current ratings coverted to amperes (X .001) 0.126 7.874 Standby: mA mA Alarm: Standby: mA mA Alarm: Standby: mA mA Alarm: Current Subtotals (in mA) 0 0 Total Current ratings of all devices in system (add A-D)(in mA) 125.760 7874.00 Total Current ratings coverted to amperes (X .001) 0.126 7.874 Page 1 l (o5 -O -5Z T-405 Protection & Communications, Inc. 19630 40th Avenue West, Suite B • Lynnwood, Washington 98036-6701 a (425) 774-9099 • FAX (425) 7746317 pro-comm-online.com Battery Calculations Page 2 Iota Standby Current Total Alarm Current A1.; total supervisory current from the Current Draw Worksheet (Row E) 0.12576 B Number of standby hours (24 and 60 for NFPA 72,E Chapter 1, 1-5.2.5 24 C Multiply Lines A and B 'Total 3.01824 �i a „' D alarm current from the current draw+ worksheet (Row E) 7.874 E Alarm sounding period in hours (for example, 5 minutes = .084 hours.) - 4 . $„ 0.084 F Multiply lines D and E. 0.661416 G Add lines C and F. 3.679656 ' 0,i Hrequired) Multiply line g by 1.2 (Fotal ampere/hours 4.4155872 , " "^x'14 "^' ,, 'gyp Page 2 • r aVsT NEV WAREI-iovsE •T'AC.E" \t‘li\RERoQ%E uLF • !":Atfti.!•4tztvezt44)4•114.:4.2)) iN '17 731 0,31.10111.04.41011114" .11 '1 • 0 r-• CC' C./ I 2: rr: c") r -r) ..2!: rt..; r to I 0 „.. • rrt tUKWILA FIRE DEPAREMLNi Please call: 575-4407 and give this job 11i11111111111T111111111f11111111IIIIITIliiiiimIIIIIIIIIVI ••••*• •••• ...db. SS& HCiFEIDC...'\1Pr 4O 7. t,00! t,i4141,,,114.4,1itigto4 174 qii"4,`V'fi'Ott!"4441 • and exact address, for shut- down or restoratiOn approval. 4, S (152 .dusty Dr. LA, VVA 9E13 , . . t.""•"'"-•••••• FLE• • This tenant improvement involves installing one new 75CD Horn Strobe to accommodate for the new construction. Pro -Comm will be using the existing SK 52107 FACP. The new 75CD Horn Strobe will be placed on ar existing circuit off of the panel. All other building devices will remain intact and are not part of this TI. INSTALLATION 75CD Horn Strobe will be installed on the wall, 80" from the bottom of the box to the floor. Without Comments D As Noted In Red El Per The Attached Letter 3 OTH E. These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. 1 Additions, deletions or revisions t these drawings after il this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. t • Final acceptance is subject to field test and inspection by ' The Tukwila Fire Prevention Bureau. Date: to/c/iq By: R CI Lynnwood. WA 98036-670 63 t40 h Ave. W. #B(425 774-9099 71111 ::0,442111 SEP 1 4 ip,si ••\?•• . .. ... ..... . . . .... ... . .2. ..... FIRE ALARM CONTROL PANEL SK 5207 !FP\ c-\"1 -1\1\rEC)L END OF LINE RESISTOR XXXX CE=) EXISTING EQUIPMENT )(XXX 0 SMOKE DETECTOR 2400 -11D4 75CD HORN STROBE NS -2475W -FR 7808 and exact address, for shut- down or restoratiOn approval. 4, S (152 .dusty Dr. LA, VVA 9E13 , . . t.""•"'"-•••••• FLE• • This tenant improvement involves installing one new 75CD Horn Strobe to accommodate for the new construction. Pro -Comm will be using the existing SK 52107 FACP. The new 75CD Horn Strobe will be placed on ar existing circuit off of the panel. All other building devices will remain intact and are not part of this TI. INSTALLATION 75CD Horn Strobe will be installed on the wall, 80" from the bottom of the box to the floor. Without Comments D As Noted In Red El Per The Attached Letter 3 OTH E. These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. 1 Additions, deletions or revisions t these drawings after il this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. t • Final acceptance is subject to field test and inspection by ' The Tukwila Fire Prevention Bureau. Date: to/c/iq By: R CI Lynnwood. WA 98036-670 63 t40 h Ave. W. #B(425 774-9099 71111 ::0,442111 SEP 1 4 ip,si ••\?•• . .. ... ..... . . . .... ... . .2. .....