HomeMy WebLinkAboutPP - 1130 INDUSTRY DR - COLLEGE HUNKS - PERMITS AND PLANS1130 INDUSTRY DR ASSOCIATED PERMITS 98-F-229 Table of Contents Project Description Battery Calculation Sheets Fire Alarm Equipment Model Description BK -2400 Ionization Smoke Detectors 692-5A 15 Candela Horn/Strobe Catalog Sheet Attached: Fire Alarm System Plans ACCEPTED Without Comments ❑ As Noted In Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally "1h the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: /0" 5 V By: 4111 Sly I(34 :TAIO 547 r ;Ne TUKWILA FIRE DEPARTMENT. Please call: 575.4407 and give this job No. /8—f--, and exact address for shut down or restoration approval. Total Standby Current Total Alarm Current A Total supervicory current from the attached calc sheet 0.12 A B Number of standby hours required (24 or 60) per NFPA 721-5.2.5 C Multiply Lines A & B 24 H 2.8800 AH D E Total alarm current from the attached calc sheet 4.56 A Alarm Sounding period (decimal eq) 0.084 H F Multiply Lines D & E 0.38304 AH G Add Lines C & F 3.2630 AH H Multiply G by 120% (Total aH req'd) 3.915648 AH Minimum Battery Required —> 3.916 Pacific Gulf Properties Building 1130 9/28/98 Decimel Minutes Equivalent 4 0.067 5 0.084 6 0.1 10 0.167 BATTERY CALCULATION FORM date: Job Name: Address: 9/28/98 Pacific Gulf Properties Building 1130, Tukwilla Device Quantity _STANDBY_ Current per device ALARM_ Current Standby Current Alarm Current per device Silent Knight 5207 FACP 1 120 mA 400 mA 120 400 mA mA 0 0 mA mA 0 0 mA mA 0 0 mA mA 0 0 mA mA 0 0 mA mA 0 0 Current Subtotals (in mA) 120 400 Smoke Detectors Quantity STANDBY Current per device ALARM_ Current Standby Current Alarm Current per device BRK-2400 Smoke Detector 29 0.12 mA 70 mA 3.48 2030 Heat Detector w/Remote 4 0 mA 44 mA 0 176 mA rnA 0 0 mA mA 0 0 mA mA 0 0 mA mA 0 0 mA mA 0 0 Current Subtotals (in mA) 3.48 2206 Notification Appliances Quantity Current Standby Current Alarm Current _ALARM_ per device Wheelock MIZ-24WM 9 127 mA 1143 Amseeco Bell 1 63 mA 63 Wheelock WS3T-24FR 1 115 mA 115 Wheelock Strobe 5 127 mA 635 ,,,A 0 mA 0 mA 0 Current Subtotals (in rnA) 1956 Other I Additional Devices/ / Quantity STANDBY Current per device ALARM_ Current Standby Current Alarm Current per device mA mA 0 0 mA mA 0 0 mA mA 0 0 mA mA 0 0 mA mA 0 0 mA mA 0 0 mA mA 0 0 Current Subtotals (in mA) 4 0 0 Total Current Requirements Standby Current Alarm Current Current rating of all devices in rnA 123.48 4562 Current ratings converted to amperes (X .001) 0.12 4.56 Mounts to Sine Gang Ring 80" above the floor, 8" below the ceiling, Which ever Isiower Existing Unit Mounts to 310 mud ring 900 Sq Foot spacing HORN/STROBE MANUAL PULL STATION SMOKE DETECTOR HORN/STROBE HEAT DETECTOR DESCRIPTION