Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 1138 INDUSTRY DR - EXECUTIVE COATING & CONTRACT - PERMITS AND PLANS
1138 INDUSTRY DR ASSOCIATED PERMITS 13-F-255 04-F-126 95-F-226 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575- Project: "174K,V i, - ,A.e: c__12. fK Type of Inspection: A— Address: U0, _ gbii Suite #: c,.-5 ®a__ Contact Person: Special Instructions: 3 g' No T Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Sprinklers: Fire Alarm: / — °-, Monitor: Pre -Fire: Permits: Occupancy Type: 3 g' No T -e3+ "Jo K rlb) t -to — 01<_, Jo — o /I( 4; - —k_ ao -- 0K /y © /, - C a, a - of( c2K ' 3,) . o C-.._ a -' ---'4 e/ iv-ee,ds -ry hw , /1-(*;) . G r c.uf _ _ .te0; a _ os. S_ — 0k_ ?3 - 0 3)— OK- K Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Date: 3//"//y Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 FILE r CONTRACTOR'S MATERIAL AND TEST CERTIFICATE FIRE ALARM AND FIRE DETECTOR SYSTEMS PROCEDURE DATE6/4 /Cr- 7-7 Upon completion of work, inspection and test shall be made by the contractor's representative and witnessed by local fire department. All defects shall be corrected and system left in service before contractor's men finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for inspecting authorities, owner and contractor. It is understood the owner's or representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship or failure to comply with inspecting authority's requirements or local ordinances. Name of Facility Pet c.411 c, tf Property Address find -1K4 146 0)4 47 Occupied as GOND{-i`c/ I Zip Code 03 Installer's Firm Name g19-4.DcAlln Address of Installer I 2O y6444VG Gt/ LIAmiikrri Electrical Contractor's License Number Aofif,S,The Wireman's Certification Number 4i//l/gthosSit%e Tests witnessed by goe Title 7/;,046 Date fat, This sto certify that this fire alarm system has been rviced (circle one) in accordance with the standards a=:pted by the local authority' having jurisdiction and is consistent with NFPA Fire Alarm Standards. A. Name of Firm Ab -4:60,m, Phone77`/4. B . Mailing Address Pr6y0 40- GU 454/WAY/ Grp' C. Name Title Date (Signature of Firm Official) Additional explanations and comments UIPMENT INSTALLED AND TES ) TYPE OF EQUIPMENT NUMBER OF UNITS TESTED TESTED DATE SATISFACTORY CHECK MODEL AND .1ANUFACTURER Yes No N/A Control Panel / -Mry/ Si Manual Station 21 (/ 6rc 4 Heat Detectors 13 j/ a ? Smoke Detectors (/ s,1{m Audible Alarm Devices 21 i/ / 14/4,e -10e. loe Visual'' Alarm Devices /Y V/ Uiky.hC Code Transmitters Automatic Door Releases Trouble Indicators Master Alarm Box Batteries _2f- Charger Generator Ventilation Control Fire Department Interconnection Central Station Interconnection p '.5* Exterior Sprinkler Electric Alarm Bell // G Sprinkler Water Flow Switch Sprinkler Gate Valve Supervision Switch Annunciators ---- Automatic Time Delay of General Alarm Minutes Test of alarm system on emergency powe,, satisfactory (Yes 00 No 0 Local Fire Department /U6}; Q Acceptable Yes ❑ No 0 Comments: A B o t -f G BATTERY CALCULATIONS FORM JOB NAME: RREEF Building #40 Current Draw Worksheet Device Number of Devices Current per Device Standby Current Alarm Current 5207 Fire Control /Communicator 1 Standby: 120mA Alarm: 400mA 120 400.000 5210 Zone Expander 0 Standby: 40mA Alarm: 40mA 0 0.000 5220 Direct Connect Module 0 Standby: 50mA Alarm: 50mA 0 0.000 5230 Remote Annunciator (7 max.) 0 Standby: 60mA Alarm: 120mA 0 0.000 4180 Status Display 0 Standby: 20mA Alarm: 140mA 0 0.000 7181 Zone Converter 0 Standby: 35rnA Alarm: 65mA 0 0.000 Current Subtotals (in mA) 120 400.000 Smoke Detectors BRK-2400 Smoke detector 54 Standby:.120mA Alarm: 70mA 6.48 3780.000 Hockiki HSC -221 L Heat Detector w/LE.D. Base 10 Standby: 0.0mA Alarm: 44mA 47 297.000 Standby: mA Alarm: mA 0 Current Subtotals (in mA) 53.48 4077.000 Continued page 2 Pro - Comm, Inc. Confidential 6/3/2004 Page 1 C Notification Devices 173.480 Current Used Total Current ratings coverted to amperes (X .001) Total (Amps) WH -125182 Hom/strobe r 0.163 Number of standby hours (24 and 60 for NFPA 72, Chapterl, 1-5.2.5 0.000 t y,�(f1 s S ° C,�°'�� C Multiply Lines A and B 4.16352 WH -126601 Strobe only Total alarm current from the current draw worksheet (Row E) 0.115 6.542 0.000 Alarm sounding period in hours (for example, 5 minutes =.084 hours.) , 0.084 F Multiply lines D and E. AS-M10BPV424 Amseco bell 1 0.063 Add lines C and F. 0.063 H Pro Rr�r�iiiredls. Multiplylineg by 1.2 (Total ampere/hours Confidontiol 5.6556576 araronna MIZ-24-WM Mini hom/strobe 11 0.127 1.397 Mini hom Federal Signal 460 024W 23 0.015 0.345 WH - 114911 WS3T-24VFR 117 Candela Outdoor Strobe 0.115 0.000 Wheelock RSSWP-2475W-FR Outside Strobe Only 1 0.102 0.102 WH - 127474 RSS-24110W-FR 110 Candela Strobe 0'161 0.000 WH - 125023 MT -12/24-R Fire Horn 0.023 0.000 WH - 125355 MT-24-IS-VFR 75 Candela hom/strobe 0'�3 0.000 WH - 125025 MT-24-WM-VFR 117 Candela hom/strobe 0'111 0.000 WH - 127806 NS -241575W -FR 15/75 Candela mini hom/strobe 0.086 0.000 Wheelock NS-24MCW-FR 75C0 Hom Strobe 0.155 0.000 Wheelock NS-24MCW-FR 110CD Hom Strobe 1 0.158 0.158 Current Subtotals (in rnA) w ;; 2065.000 Total Current ratings of all devices in system (add A-D)(in mA) 173.480 6542.000 Total Current ratings coverted to amperes (X .001) 0.173 6.542 Battery Calculations Page 2 Total Standby Current I Total Alarm Current A Total supervisory current from the Current Drawper Worksheet (Row E) 0.17348 r B Number of standby hours (24 and 60 for NFPA 72, Chapterl, 1-5.2.5 24 t y,�(f1 s S ° C,�°'�� C Multiply Lines A and B 4.16352 D Total alarm current from the current draw worksheet (Row E) it a ''i 6.542 E Alarm sounding period in hours (for example, 5 minutes =.084 hours.) , 0.084 F Multiply lines D and E. . 1 0.549528 G Add lines C and F. 4.713048 H Pro Rr�r�iiiredls. Multiplylineg by 1.2 (Total ampere/hours Confidontiol 5.6556576 araronna Page 2 Navikaticn Technobgle S 1 Both St 1 &nth St BUILDING CROSS SECTION ALL NOTIFICATION DEVICES 80" FROM THE FLOOR PULLS 48" FROM THE FLOOR JOB \OTLS: THIS J03 I\VOLVES EXPANDING THE EXISTI\G FIRE •ALARIi SYSTEV TO ACCON v1ODATE FOR THE TENANT IMPROVEMENT OF SUITES 1138 & 1140 OF RREEF BLDG. #40. PRO -COMM WILL BE ADDING ONE NEW PULL STATION AND ONE NEW HORN STROBE TO PROVIDE ADEQUATE COVERAGE WITHIN THE WAREHOUSES. PRO -COMM WILL BE RELOCATING ONE EXISTI,\G PULL STATION AND ONE EXISTING HORN STROBE. (SEE PLANS ''Ft0R LOCATION). THE NEW NOTIFICATION DEVICE AND PULL STATION WILL BE INSTALLED ON AN EXISTING CIRCUIT/ZONE WITH THE SPACE. ALL DEVICES THAT ARE EXISTING ARE vARKED WITH AN "E", ALL DEVICE THAT ARE EXISTING A\D TO 3E RELOCATED ARE MARKED "E,R". PLEASE \OTE THAT NO NEW ZONES WILL 3E ADDED TO THE EXISTI\G PA\EL, AND NO OTHER WORK WILL 3E PERFORMED ON THE SYSTEM. I\STALLATIO\: —SV OKE DETECTORS TO BE I\STALLED ON THE CEILING. —PULL STATIONS WILL 3E I\STALLED 48" -FROM TOP OF THE 30X TO THE FLOOR. —NOTIFICATION DEVICES TO BE INSTALLED 80" FROM THE BOTTOV OF THE BOX TO THE FLOOR FIRE ALARM MO NI'70 RING- AVAILA3LE BY: PRO -CONN (L25) 774-9099 1-800-774-9099 E,R J 0 w EXISTING CIRCUIT IN FROM EXISTING DEVICE A FACP J 0 w J 0 w EXISTING CIRCUIT IN FROM EXISTING DEVICE LOCATION OF FACP: ELECTRICAL ROOM MAIN FLOOR SMOKE AT PANEL EXISTING ADJACENT SPACE NEW DEVICES EXISTING WAKE.1-1O5e. EXISTING OPE.N WORK AREA EXISTING orrice. EXISTING orrice ISTING B T11 D P H E,R DEVICES RELOCATED FROM HERE EXISTING WAKE.FIOSE EXISTING OFFICE. EXISTI BA 5U11L 11+o EXISTING RECEPTION 5U1TE. 1138 EXISTING RECEPTION J FL00TI SLA\ XIST!NG OFFICE. EXISTING orrice EXISTING orrice EXISTING orrlcE SCALE: 1 /8"= 1'-0" <IN FROM EXISTING CIRCUIT/DEVICE < IN FROM EXISTING CIRCUIT/DEVICE RR 1138-11 0 IN ,S_RY DR T INE, RR 7 BLIGI C, J-C`tiIL_4, \1A 98188 SYMBOL DESCRIPTION FACP * EO LR P EXISTING SILENT KNIGHT 5207 FIRE PANEL END OF LINE RESISTOR PULL STATION SMOKE DETECTOR 75CD HORN STROBE 110CD HORN STROBE 75CD STROBE ONLY CCEPTE Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this,acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention. Bureau. TUKWILA FIRE DEPART MLNY Please call: 575-4407 and give this job No. ("7—/-7 / and exact address for shut• down or restoration approval, 03e —/, sio ,:ZAiA 1 FIRE DEPARTMENT USE ONLY FILE PRO—COMM PROJ. BLDG. #40 SCALE: 1/8"= 1'-0" 1 PROJECT ADDRESS 0 >- m w 0 a co ct a OO r - 0J(5) Z c1 >< cn I CL COs: NDwY w J REVISIONS (SUBMITTAL 0'' N 0 0 U O• — G. 1 yJ I 0 E E 0 U c 0 0 Q) 0 0 CZ) m C m REFERENCE RELEASE DATE: 5/28/04 SHEET NUMBER 1 OF n .A..1E12$ JUN 3 2004 229K( poci 00 ~ ee