PP - 509 INDUSTRY DR - UNKNOWN - PERMITS AND PLANS
509 INDUSTRY DR ASSOCIATED PERMITS 877036 866205 866166 877035 866204 866152 877006 866168 866206 866167 City of Tukwila Department Fire Gary VanDusen Mayor Hubert H. Crawley Fire Chief January 16, 1987 Cartland Alarm 30459 Military Road South Federal Way, Wa. 98003 Re: Equitec - 509 Industry Drive, #13 Dear Sir: The fire alarm system plans affixed hereto have been reviewed and accepted as meeting or exceeding minimum requirements of the City of Tukwila Fire Department, Bureau of Fire Prevention, with the following notes: 1. Maintain square foot coverage of detectors per manufacturer's specifications in all areas including; closets, elevator shafts, top of stairwells, etc. (NFPA 72A, 1-2.2 & NFPA 72E) 2. Wire shall be in conduit or be UL listed Fire Protective Signaling Circuit Cable. (NFPA 72A, 2-2.1) 3. Remote indicator lights are required on all above ceiling smoke detectors. 4. A rechargeable battery back-up is required on any fire alarm installation. There shall be enough battery capacity to run the alarm system in standby for twenty-four (24) hours and, after that time, sound all alert devices for at least five (5) minutes. (NFPA 72A, 2-3.4.2) 5. All restrooms, kitchens, laundry rooms, boiler rooms or any room where there is apt to be moisture, shall have fixed temperature heat detectors installed. These detectors should have replaceable links for testing purposes. 6. A satisfactory contract covering the maintenance, operation and efficiency of the system shall be provided by the property owner. The contract shall provide for periodic inspection and tests, for proper maintenance service, and for service following operation of the system and shall be acceptable to the authority having jurisdiction. (NFPA 72A, 1-2.4.1) 7. All devices City of Tukwila combination of devices, appliances and Fire Department, 444 Andover Park East, Tukwila, Washington 98188 (206) 575-4404 City of Tukwila Fire Department Page number 2 Gary VanDusen Mayor Hubert H. Crawley Fire Chief equipment installed shall be listed for the protective signaling purpose for which they are used. (NFPA 72A, 1-2.2) The above items are a general synopsis of requirements for Fire Alarm Systems required by City Ordinance #1327, and are not intended. to detail all requirements of NFPA #72. Final approval is subject to the fulfillment of requirements of NFPA #72 and a successful functional test accomplished by the installer (witnessed by the Fire Department) upon completion of the system. Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. File F.P.O. Peterson slj City of Tukwila Fire Department, 444 Andover Park East, Tukwila, Washington 98188 (206) 575-4404 City of Tukwila Fire Department Gary VanDusen Mayor Hubert H. Crawley Fire Chief Cartland Alarm. 30459 Military Road South Federal Way, Washington 98003 March 3, 1987 Re: Equitec - 509 Industry Drive, Bldg. *14 Dear Sir: The fire alarm system plans affixed hereto have been reviewed and accepted as meeting or exceeding minimum requirements of the City of Tukwila Fire Department, Bureau of Fire Prevention, with the following notes: 1. Maintain square foot coverage of detectors per manufacturer's specifications in all areas including; closets, elevator shafts, top of stairwells, etc. (NFPA 72A, 1-2.2 & NFPA 72E) 2. Wire shall be in conduit or be UL listed Fire Protective Signaling Circuit Cable. (NFPA 72A, 2-2.1) 3. Local UL Central Station supervision is required. (City Ordinance *1327) 4. Remote indicator lights are required on all above ceiling smoke detectors. 5. Alarm circuits shall be arranged so that the occurrance of a single break or single ground fault will be indicated by a distinctive trouble signal. (NFPA 72A, 2-4.1) 6. A rechargeable battery back-up is required on any fire alarm installation. There shall be enough battery capacity to run the alarm system in standby for twenty-four (24) hours and, after that time, sound all alert devices for at least five (5) minutes. (NFPA 72A, 2-3.4.2) 7. All restrooms, kitchens, laundry rooms, boiler rooms or any room where there is apt to be moisture, shall have fixed temperature heat detectors installed. These detectors should have replaceable links for testing purposes. 8. Remote larm & trouble annunciation indication is City of Tukwila Fire Department, 444 Andover Park East, Tukwila, Washington 98188 (206) 575-4404 City of Tukwila Fire Department Page number Gary VanDusen Mayor Hubert H. Crawley Fire Chief required if the control panel is not visible from the main entrance. (NFPA 72A, 2-4.4.1) 9. A satisfactory contract covering the maintenance, operation and efficiency of the system shall be provided by the property owner. The contract shall provide for periodic inspection and tests, for proper maintenance service, and for service following operation of the system and shall be acceptable to the authority having jurisdiction. (NFPA 72A, 1-2.4.1) 10. Audible signal devices shall be installed to indicate a fire alarm condition. They shall be so located that their operation will be heard clearly, regardless of the maximum noise level. (NFPA 72A, 2-5.4) 11. All devices, combination of devices, appliances and equipment installed shall be listed for the protective signaling purpose for which they are used. (NFPA 72A, 1-2.2) 12. Maintenance and/or replacement of automatic fire detectors shall be the responsibility of the building or unit owner or his agent. Assure that all smoke detectors are operable. (City Ordinance #1327) Please provide this office with written documentation of the last inspection conducted on the automatic fire detector units. The above items are a general synopsis of requirements for Fire Alarm Systems required by City Ordinance #1327, and are not intended to detail all requirements of NFPA #72. Final approval is subject to the fulfillment of requirements of NFPA #72 and a successful functional test accomplished by the installer (witnessed by the Fire Department) upon completion of the system. Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. File ncd City of Tukwila Fire Department, 444 Andover Park East, Tukwila, Washington 98188 (206) 575-4404 • City of Tukwila Department `Pt,. cr. �; �',�,� Y� F C'�rtland Al m `` 30459 Mili aryRoad South ,qa�G-, �: a'4' � ' SEattle, a. 98003 abe,r expo 7 'albso.' q ; .. •�, •i` 7,, S 6/gyp'" � • c,� p�O,c7'�1,�3OA e: Equitec Properties - 509 Industry Drive, Bldg. #4, eo�f. ra��// ST wile, Wa. N / o��hsa tear Sir: Gary VanDusen Mayor Hubert H. Crawley Fire Chief October 30, 1986 The fire alarm system plans affixed hereto have been reviewed and accepted as meeting or exceeding minimum requirements of the City of Tukwila Fire Department, Bureau of Fire Prevention, with the following notes: 1. Maintain square foot coverage of detectors per manufacturer's specifications in all areas including; closets, elevator shafts, top of stairwells, etc. (NFPA 72A, 1-2.2 & NFPA 72E) 2. Wire shall be in conduit or be UL listed Fire ,Protective Signaling Circuit Cable. (NFPA 72A, 2-2.1) 3. Remote indicator lights are required on all above ceiling smoke detectors. 4. Alarm circuits shall be arranged so that the occurrance of a single break or single ground fault will be indicated by a distinctive trouble signal. (NFPA 72A, 2-4.1) 5. A rechargeable battery back-up is required on any fire alarm installation. There shall be enough battery capacity to run the alarm system in standby for twenty-four (24) hours and, after that time, sound all alert devices for at least five (5) minutes. (NFPA 72A, 2-3.4.2) 6. All restrooms, kitchens, laundry rooms, boiler rooms or any room where there is apt to be moisture, shall have fixed temperature heat detectors installed. These detectors should have replaceable links for testing purposes. 7. Key box - When access to or within a structure or an area is unduly difficult because of secured openings or where immediate a cess is necessary for life-saving or 1 ay of Tukwila Fire Department, 444 Andover Park East, Tukwila, Washington 98188 (206) 575-4404 City of Tukwila Gary VanDusen Mayor Fire De arty hent Pale number 2 Hubert H. Crawley Fire Chief fire -fighting purposes, the Chief may require.a key box to be installed in an accessible location. The key box shall be a type approved by the Chief and shall contain keys to gain necessary access as required by the Chief. (UFC 10.209) 8. A satisfactory contract covering the maintenance, operation and efficiency of the system shall be provided by the property owner. The contract shall provide for periodic inspection and tests, for proper maintenance service, and for service following operation of the system and shall be acceptable to the authority having jurisdiction. (NFPA 72A, 1-2.4.1) 9. Audible signal devices shall be installed to indicate a fire alarm condition. They shall be so located that their operation will be heard clearly, regardless of the maximum noise level. (NFPA 72A, 2-5.4) 10. Maintenance and/or replacement of automatic fire detectors shall be the responsibility of the building or unit owner or his agent. Assure that all smoke detectors are operable. (City Ordinance #1327) Please provide this office with written documentation of the last inspection conducted on the automatic fire detector units. The above items are a general synopsis of requirements for Fire Alarm Systems required by City Ordinance #1327, and are not intended to detail all requirements of NFPA #72. Final approval is subject to the fulfillment of requirements of NFPA #72 and a successful functional test accomplished by the installer (witnessed by the Fire Department) upon completion of the system. Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. File slj City of Tukwila Fire Department, 444 Andover Park East, Tukwila, Washington 98188 (206) 575-4404 flesign en ineers ACCEPTED �j • COMMENTS. S NOTED 1N RED PER THE ATTACHED i.ETfER The Wirings affixed hereto have been reviewed and accepted by the City of Tukwila Fire Dept. Ad Voris. 4et4tions or revisions to th2s3 t'r ti iia afa=r ;pis date will void this actli)t- r --e aria will require a resubmittal of rern.sed 1rwwrings Finat acceptance is sublist..t b fte13- inspection by a representative of bus emartment DATE .19$8Y 4 C1TY OF TUKWILA 575 4407 F CoWTKOL UNIT ©Pu STA FixELC TEmQERPTGIRt Q RTE ilisE S . QLTESTotk. B1=Laui 0E111).9 11 Abot'E C FI Li>ug W iTh REV o7 -1/E, Am i\IIA ecu T i. Bu.LtER TERmiNATIN9 QEVICE t' KVI11LA TIRE DEPARTMDA ',Please call* 575-4407 and give this kab No 86fj1 52 and exact address for shuts down or restoration appr JOB NO 8E36971 DRAWN GI —% g' ga<i CHECKED ISSUED REVISED- 1a— (-36, MSL SHEET ti •• ZONE 3 ZONE 7 I?Frri ©TY QE.S.C.RIPTON tDMT1rL. PAtoEL ENC`Dsu,�cE PART ND IY1Atiuw D811z113 RADIONICS DF10q 3 0 DttEL f,AJ1EptY iiAR4JE56 PR11t x 1Z UDC 6 fill 5 — CdMr1 Ind 0 -A -grip,) 01252 14,-17 18-1i 20 — 41 P.nuJe2 Loop INTTER1'Acb .g ELL 11.PiClifloril Ci I OcT3 RELAY • _I ST U, 10 5 ThtRmn5Tar tas• 5D RATE r SZk ZDIU E .5 (1J�QE IO50C 3m volt 2Q ; Pht113ELa..Trzic °--wings. 0E1 I5 G QEM nrE. LED, FgAin !ik^IS r PLEzo �-)LEQT g01:713. 17 11/1,ni u PiA!L cTAT,m ) ,PuRb)8y All RD l R2 2 Lh9-bra r/ 329511/ *Ps CA 52-9 AVEMCO Zdt!L2 JOB NO B6991 DRAWN _/E3`U6. CHECKED ISSUED REVISED lD-i --tG SHEET li f 1 1 et z 7D +neParR r141; ZCNL (i'7 Intkw dEPARTMENT it I be calf, 575.4407 o I give this job p lrl ' 8ti6168 end exact address for shut. town or restoration apprcvat Q v /k ONE5 To 2P-4FLcaa uP ---a---L---a 0 d 1 1 } 1 2O 1J 6 8 F c N CONTROL uN,r D "Ta FIXEO TFmpEsATu.RE 0 RATE tyt R SMOKE f0E7- 11 !/ uitig Rzotore BtAIZ Le EE LOU CE1LITJ!3 FERnn11UAT,w9 DEJ1CLc flesign en ineers o cJ o z o y£. cc �_ 'ZIQ 7:1 �. � 3 to -J N Tr cc� 1 M W N 0) m LU L-=< n n 0 1\ Ufl� W 7_► OOD W tr) l-- PROTEC T1 Ok LU i LL z CI_ 0 LL JOB NO 88699 DRAWN / o -9—g, CHECKED -.1,1i111-"CaLiff REVIS t T131e UftwILA Fife PA.: --'E vflo N BU�4£��-•� n'ZiL SHEET • 1 3 S+nw[F r,atvG t2ax 0E5 R1PTcrsi C. 0 NI TSVa . 9a r1 e_ 1- E.Tuc.Lonui E DuEi BairCf NAR11ES9 flHT1LRy 12Vor_ 1014, CamnjA1VD .TaTsoN Powe Loop TriTaRFAcE BECK CIQCUIT 5u IE S10 °CTo RELAY 5T U (YlnnuaL PULL SrATIf»J TOE RThO hT 135°F R ATE (A' 1115E LOIRE. 105°C 300 VaLT' 11 11 11 PIEL0 ALERT Oil P1a0To t=LECTR\ t= .Sn1OSE Der. RtrAcite ANNuNC►RTaR D12ta ni2s2 D 125 0192 D8129 WI8LIL 52q 502 t01 11 11 ADEMCO 11 SII I~D 182 11 32Bt1f Ailt15ELO 2..satio B R 1 1 SECOND FLOOR BLDG.4 .7 • 1. 1-13 q- 11 Z6 Z5 -7- 3-4 7-- 3-4 12 13 IN -1 11- t3 14-1 Z4 Z3 Z2 A i 1- 2 'I.-5 7- S 17 yyr �-g J 1G 11 flesign eno ineers Z W O a_ O O W W O �U 06 Ul Lil <C t; LCA W (ff) ne MILITARY ROAD SO 0 u� 0 JOB NO 88c?9/ DRAWN /040- jn CHECKED ISSUED REVISED p R.,. Fra WY_ ;9./ } �j OFi7F ,1 SHEET PRivtivifoN 8(/ 1 4 City of Tukwila Fire Department .6040 Gte e N° r\ry ecet c a . P.0-. SSA\g NP.ecti Je o'� set` z Gary VanDusen Mayor Hubert H. Crawley Fire Chief Cartland Alarm 30459 Military Road South Seattle, Wa. 98003 Otober 30, 1986 R Equitec - 509 Industry Drive, Bldg. #5 Sir: e alarm system plans affixed hereto have been d and accepted as meeting or exceeding minimum irements of the City of Tukwila Fire Department, Bureau Fire Prevention, with the following notes: 1. Maintain square foot coverage of detectors per manufacturer's specifications in all areas including; closets, elevator shafts, top of stairwells, etc. (NFPA 72A, 1-2.2 & NFPA 72E) 2. Wire shall be in conduitor be UI, listed Fire Protective Signaling Circuit Cable. (NFPA 72A, 2-2.1) 3. Remote indicator lights are required on all above ceiling smoke detectors. 4. Alarm circuits shall be arranged so that the occurrence of a single break or single ground fault will be indicated by a distinctive trouble signal. (NFPA 72A, 2-4.1) 5. A rechargeable battery back-up is required on any fire alarm installation. There shall be enough battery capacity to run the alarm system in standby for twenty-four (24) hours and, after that time, sound all alert devices for at least five (5) minutes. (NFPA 72A, 2-3.4.2) 6. All restrooms, kitchens, laundry rooms, boiler rooms or any room where there is apt to be moisture, shall have fixed temperature heat detectors installed. These detectors should have replaceable links for testing purposes. 7. Key box - When access to or within a structure or an area is unduly difficult because of secured openings or where immediate acess is necessary for life-saving or fire -fighting pur oses, the Chief may require a key box to City of Tukwila Fire Department, 444 Andover Park East, Tukwila, Washington 98188 (206) 575-4404 City of Tukwila Gary VanDusen Mayor Fire Department Page number 2 Hubert H. Crawley Fire Chief be installed in an accessible location. The key box shall be a type approved by the Chief and shall contain keys to gain necessary access as required by the Chief. (UFC 10.209) 8. A satisfactory contract covering the maintenance, operation and efficiency of the system shall be provided by the property owner. The contract shall provide for periodic inspection and tests, for proper maintenance service, and for service following operation of the system and shall be acceptable to the authority having jurisdiction. (NFPA 72A, 1-2.4.1) 9. Audible signal devices shall be installed to indicate a fire alarm condition. They shall be so located that their operation will be heard clearly, regardless of the maximum noise level. (NFPA 72A, 2-5.4) 10. Maintenance and/or replacement of automatic fire detectors shall be the responsibility of the building or unit owner or his agent. Assure that all smoke detectors are operable. (City Ordinance #1327) Please provide this office with written documentation of the last inspection conducted on the automatic fire detector units. The above items are a general synopsis of requirements for Fire Alarm Systems required by City Ordinance #1327, and are not intended to detail all requirements of NFPA #72. Final approval is subject to the fulfillment of requirements of NFPA #72 and a successful functional test accomplished by the installer (witnessed by the Fire Department) upon completion of the system. Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. File slj City of Tukwila Fire Department, 444 Andover Park East, Tukwila, Washington 98188 (206) 575-4404 r 0- - r F- t uP y N F e CorvTroL U�JIT FI YE. '0 ERATURE _ ® RATE t4 1 1' ! MAIN FL OO i TO KPP!. ' F1.004 ,d 5. .� s_ ♦ , 1' It‘ea t�� ��vi szetov4 04,1: ock Vv" G" TUKWILA FIRE DEPARTMENT Please call. 575.4407 .nd give this job No 866167 and exact address for shut- down or restoration approvals, IP OK - E01. SniercE nET BELow CEILING 11 1J AEr^vE 'l 5,AZ G.E g.. TERIYIINATINL DEYICE O co rn O 1-- 2 3 to JN O W h• O h LU W J� W z (r) UJ % D 00 W L.,ri u w E_- 0 W LL (v_ 0 0 J •; DRACyl,,U EC%?aP iz D 1 ISSUI&'R£1,FNTo98e REVISED �eeitq SHEET + of �e to Ge• o as QJ\ Qa\ct� CIc4.4 Hubert Fire P. rawley of Carland Alarm 30459 Military Road South Seattle, Wa. 98003 October 30, 1986 Re: Equitec - 509 Industry Drive, Bldg. #6, Tukwila, Wa. Dear Sir: The fire alarm system plans affixed hereto have been reviewed and accepted as meeting or exceeding minimum requirements of the City of Tukwila Fire Department, Bureau of Fire Prevention, with the following notes: 1. Maintain square foot coverage of detectors per manufacturer's specifications in all areas including; closets, elevator shafts, top of stairwells, etc. (NFPA 72A, 1-2.2 & NFPA 72E) 2. Wire shall be in conduit or be UL listed Fire Protective Signaling Circuit Cable. (NFPA 72A, 2-2.1) 3. Remote indicator lights are required on all above ceiling smoke detectors. 4. Alarm circuits shall be arranged so that the occurrance of a single break or single ground fault will be indicated by a distinctive trouble signal. (NFPA 72A, 2-4.1) 5. A rechargeable battery back-up is required on any fire alarm installation. There shall be enough battery capacity to run the alarm system in standby for twenty-four (24) hours and, after that time, sound all alert devices for at least five (5) minutes. (NFPA 72A, 2-3.4.2) 6. All restrooms, kitchens, laundry rooms, boiler rooms or any room where there is apt to be moisture, shall have fixed temperature heat detectors installed. These detectors should have replaceable links for testing purposes. 7. Key box - When access to or within a structure or an area is unduly difficult because of secured openings or where immediate access is necessary for life-saving or fire -fighting puroses, the Chief may require a key box to City of Tukwila Fire Department, 444 Andover Park East, Tukwila, Washington 98188 (206) 575-4404 V City of Tukwila Fire Department Page number 2 Gary VanDusen Mayor Hubert H. Crawley Fire Chief be installed in an accessible location. The key box shall be a type approved by the Chief and shall contain keys to gain necessary access as required by the Chief. (UFC 10.209) 8. A satisfactory contract covering the maintenance, operation and efficiency of the system shall be provided by the property owner. The contract shall provide for periodic inspection and tests, for proper maintenance service, and for service following operation of the system and shall be acceptable to the authority having jurisdiction. (NFPA 72A, 1-2.4.1) 9. Audible signal devices shall be installed to indicate a fire alarm condition. They shall be so located that their operation will be heard clearly, regardless of the maximum noise level. (NFPA 72A, 2-5.4) 10. Maintenance and/or replacement of automatic fire detectors shall be the responsibility of the building or unit owner or his agent. Assure that all smoke detectors are operable. (City Ordinance *1327) Please provide this office with written documentation of the last inspection conducted on the automatic fire detector units. The above items are a general synopsis of requirements for Fire Alarm Systems required by City Ordinance *1327, and are not intended to detail all requirements of NFPA *72. Final approval is subject to the fulfillment of requirements of NFPA #72 and a successful functional test accomplished by the installer (witnessed by the Fire Department) upon completion of the system. Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. File slj City of Tukwila Fire Department, 444 Andover Park East, Tukwila, Washington 98188 (206) 575-4404 r n\�1 �y AJ,c,`C2'� . `Q ":" 015">\* iyEQaa � ,co, oy�° ''' gea,ate`��r °eA, 042' _ 6. — sts,e— ,N - 0,y, L7— a - CF ---C7 O D a Tb rl4I N F%•ort d—o ti zoo 7 ZONE( ` flesign engineers 1 0 m z 0 u w F=- 0 W LL z —J C2 0 0 LL JOB NO R891 DRAWN 10 -22-86 CHECKED ISSUED REVISED 1014 /Kg, SHEET City of Tukwila Fire Department Gary VanDusen Mayor Hubert H. Crawley Fire Chief December 16, 1986 Cartland Alarms 30459 Military Road South Federal Way, Washington 98003 Re: Equitec - 509 Industry Drive, #8, Tukwila, Wa. Dear Sir: The fire alarm system plans affixed hereto have been reviewed and accepted as meeting or exceeding minimum requirements of the City of Tukwila Fire Department, Bureau of Fire Prevention, with the following notes: 1. Maintain square foot coverage of detectors per manufacturer's specifications in all areas including; closets, elevator shafts, top of stairwells, etc. (NFPA 72A, 1-2.2 & NFPA 72E) 2. Local UL Central Station supervision is required. (City Ordinance #1327) 3. Remote indicator lights are required on all above ceiling smoke detectors. 4. Alarm circuits shall be arranged so that the occurrance of a single break or single ground fault will be indicated by a distinctive trouble signal. (NFPA 72A, 2-4.1) 5. A rechargeable battery back-up is required on any fire alarm installation. There shall be enough battery capacity to run the alarm system in standby for twenty-four (24) hours and, after that time, sound all alert devices for at least five (5) minutes. (NFPA 72A, 2-3.4.2) 6. All restrooms, kitchens, laundry rooms, boiler rooms or any room where there is apt to be moisture, shall have fixed temperature heat detectors installed. These detectors should have replaceable links for testing purposes. 7. A satisfactory contract covering the maintenance, operation and efficiency of the system shall be provided by the property owner. The contract shall provide for periodic inspection and tests, for proper maintenance City of Tukwila Fire Department, 444 Andover Park East, Tukwila, Washington 98188 (206) 575-4404 ii City of Tukwila Fire Department Page number 2 Gary VanDusen Mayor Hubert H. Crawley Fire Chief service, and for service following operation of the system and shall be acceptable to the authority having jurisdiction. (NFPA 72A, 1-2.4.1) 8. Audible signal devices shall be installed to indicate a fire alarm condition. They shall be so located that their operation will be heard clearly, regardless of the maximum noise level. (NFPA 72A, 2-5.4) 9. Maintenance and/or replacement of automatic fire detectors shall be the responsibility of the building or unit owner or his agent. Assure that all smoke detectors are operable. (City Ordinance *1327) Please provide this office with wr.itten documentation of the last inspection conducted on the automatic fire detector units. The above items are a general synopsis of requirements for Fire Alarm Systems required by City Ordinance *1327, and are not intended to detail all requirements of NFPA *72. Final approval is subject to the fulfillment of requirements of NFPA *72 and a successful functional test accomplished by the installer (witnessed by the Fire Department) upon completion of the system. Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. File Lavern Peterson Fire Prevention Officer slj City of Tukwila Fire Department, 444 Andover Park East, Tukwila, Washington 98188 (206) 575-4404 11 2or3E 8 i N ZDN67 Q O----i]— r� 11 0 L 1 1 w1 0- �}--ti--c it - UPPER FLOCG Mfg I N FLOOR f t4 Ft-oarZ Tc epea FL o' It TUKW Pie se Icalf LA FIRE p and se 575 4407T MENT this lob No��, �. and exact address � � � � V tj for shut- down or restoration atio n approvab ACCEPTED ® WITHOUT COMMENTS. AS NOTED IN RED PER THE ATTACHED LETTER The drawings affixed hereto have b2en reviewed and accepted by the City of Tukwila Fire Dept Additions, deletions or revisions to these drawr i s after this date will void this acce,t,n 3 en! win require a resubmittal or raria.-- ,:.ir ,, Final acceptance is suasect fi .I ! vings, inspection bya represeritati,a t rr; departmen �o DATE 43 BY 575.4407 OD C) e— 1 flesign eno ineers 30459 MILITARY ROAD SO 0 >= J W~ or• cos m W LW — uJ 0 11_1 V D Oo� W I-- L1J I—� `s J J z O LU 7 ce 0 0 I1 61C JOB N0886991 DRAWN 10 -30-86 CHECKED ISSUED REVISED 9Q6 ACC 1015 575-0867 SHEET NUL L i City of Tukwila Fire Department Gary VanDusen Mayor Hubert H. Crawley Fire Chief December 16, 1986 Cartland Alarms 30459 Military Road South Federal Way, Washington 98003 Re: Equitec - 509 Industry Drive, #9 Dear Sir: The fire alarm system plans affixed hereto have been reviewed and accepted as meeting or exceeding minimum requirements of the City of Tukwila Fire Department, Bureau of Fire Prevention, with the following notes: 1. Maintain square foot coverage of detectors per manufacturer's specifications in all areas including; closets, elevator shafts, top of stairwells, etc. (NFPA 72A, 1-2.2 & NFPA 72E) 2. Local UL Central Station supervision is required. (City Ordinance #1327) 3. Remote indicator lights are required on all above ceiling smoke detectors. 4. A rechargeable battery back-up is required on any fire alarm installation. There shall be enough battery capacity to run the alarm system in standby for twenty-four (24) hours and, after that time, sound all alert devices for at least five (5) minutes. (NFPA 72A, 2-3.4.2) 5. Alarm circuits shall be arranged so that the occurrance of a single break or single ground fault will be indicated by a distinctive trouble signal. (NFPA 72A, 2-4.1) 6. All restrooms, kitchens, laundry rooms, boiler rooms or any room where there is apt to be moisture, shall have fixed temperature heat detectors installed. These 'detectors should have replaceable links for testing purposes. 7. A satisfactory contract covering the maintenance, operation and efficiency of the system shall be provided by the property owner. The contract shall provide for periodic inspection and tests, for proper maintenance City of Tukwila Fire Department, 444 Andover Park East, Tukwila, Washington 98188 (206) 575-4404 City of Tukwila Fire Department Page number 2 Gary VanDusen Mayor Hubert H. Crawley Fire Chief service, and for service following operation of the system and shall be acceptable to the authority having jurisdiction. (NFPA 72A, 1-2.4.1) 8. Audible signal devices shall be installed to indicate a fire alarm condition. They shall be so located that their operation will be heard clearly, regardless of the maximum noise level. (NFPA 72A, 2-5.4) 9. Maintenance and/or replacement of automatic fire detectors shall be the responsibility of the building or unit owner or his agent. Assure that all smoke detectors are operable. (City Ordinance #1327) Please provide this office with written documentation of the last inspection conducted on the automatic fire detector units. The above items are a general synopsis of requirements for Fire Alarm Systems required by City Ordinance *1327, and are not intended to detail all requirements of NFPA *72. Final approval is subject to the fulfillment of requirements of NFPA *72 and a successful functional test accomplished by the installer (witnessed by the Fire Department) upon completion of the system. Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. File Lavern Peterson, Fire Prevention Officer slj City of Tukwila Fire Department, 444 Andover Park East, Tukwila, Washington 98188 (206) 575-4404 c Or- v. r ax r 1 TUKWILA FIRE DEPARTMENT Please call. 575.4407 and give this lob No 8 i32O5 i.nd . xact address for shut- down or restoration approval. ACCEPTED ❑ WITHOUT COMMENTS ❑ A.) NuTED IN RED PcR THE ATTACHED LETTER The drawings affixed hereto have been reviewed and accepted by the City of Tukwila Fire Dept Additions, deletions or revisions !o t'iase drawings after this date will void this acceptan:.e and will require a resubmittal of revised drawings Final acceptance is subject to field - inspection by,e_ representative of this department DATE CITY OF TUKWILA 575.4407 /8"= flesign en ineers QZ Zo <1—(- P..1 o� Jo w >� w o �U W cc U-1 „ w ce N ti ti N uJ I+� J- L lir uJ 0 C LL JOB NO 886991 DRAWN 11-14 -86 CHECKED ISSUED REVISED 997 ACC: 588 SHEET City of Tukwila Fire Department Gary VanDusen Mayor Hubert H. Crawley Fire Chief December 16, 1986 Cartland Alarms 30459 Military Road South Federal Way, Washington 98003 Re: Equitec - 509 Industry Drive, #10, Tukwila, Wa. Dear Sir: The fire alarm system plans affixed hereto have been reviewed and accepted as meeting or exceeding minimum requirements of the City of Tukwila Fire Department, Bureau of Fire Prevention, with the following notes: 1. Maintain square foot coverage of detectors per manufacturer's specifications in all areas including; closets, elevator shafts, top of stairwells, etc. (NFPA 72A, 1-2.2 & NFPA 72E) 2. Local UL Central Station supervision is required. (City Ordinance *1327) 3. Remote indicator lights are required on all above ceiling smoke detectors. 4. Alarm circuits shall be arranged so that the occurrance of a single break or single ground fault will be indicated by a distinctive trouble signal. (NFPA 72A, 2-4.1) 5. A rechargeable battery back-up is required on any fire alarm installation. There shall be enough battery capacity to run the alarm system in standby for twenty-four (24) hours and, after that time, sound all alert devices for at least five (5) minutes. (NFPA 72A, 2-3.4.2) 6. All restrooms, kitchens, laundry rooms, boiler rooms or any room where there is apt to be moisture, shall have fixed temperature heat detectors installed. These detectors should have replaceable links for testing purposes. 7. A satisfactory contract covering the maintenance, operation and efficiency of the system shall be provided by the property owner. The contract shall provide for periodic inspection and tests, for proper maintenance ay of Tukwila Fire Department, 444 Andover Park East, Tukwila, Washington 98188 (206) 575-4404 r 1 City of Tukwila Fire Deparumbertm2ent Pa a n Gary VanDusen Mayor Hubert H. Crawley Fire Chief service, and for service following operation of the system and shall be acceptable to the authority having jurisdiction. (NFPA 72A, 1-2.4.1) 8. Audible signal devices shall be installed to indicate a fire alarm condition. They shall be so located that their operation will be heard clearly, regardless of the maximum noise level. (NFPA 72A, 2-5.4) 9. Maintenance and/or replacement of automatic fire detectors shall be the responsibility of the building or unit owner or his agent. Assure that all smoke detectors are operable. (City Ordinance *1327) Please provide this office with written documentation of the last inspection conducted on the automatic fire detector units. The above items are a general synopsis of requirements for Fire Alarm Systems required by City Ordinance *1327, and are not intended to detail all requirements of NFPA *72. Final approval is subject to the fulfillment of requirements of NFPA *72 and a successful functional test accomplished by the installer (witnessed by the Fire Department) upon completion of the system. Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. File Lavern Peterson, Fire Prevention Officer slj City of Tukwila Fire Department, 444 Andover Park East, Tukwila, Washington 98188 (206) 575-4404 k l` t { a .- ../ .......... ..w/m•r*...0f*•• wIce.,*+• r .1.1_J- .‘ , .‘r 3 , .46 1- z i7 Et 1=1 i r 110 1 0 40 4,,,,T 1 440 l z2 r i r a f E i 1 i --sr--------�, i¢AOidde uor;eJo;sal Jo UMop •;nys Joh ssaappe;oexa pue qo Sly# eA18 pue LOVii•SLS ilea nook! 1N3W121Vd30 V1IM)tflj 'Ott SLg V1IN Mill 3O A1I3L, A8 _.. _.,„ 31110 0 o� ;uew;Jedap elft 'o P/'ge;uaseic+a.r a ((C1 uCi;3adsul 1 1U1, �; l��•icr{s sr a3ue;daoae 1eur,� S !Ir' �'r �a�l' as :� Ipp;IwgnsaA a annbei 11I°' LiAj t srta FIOA HIM s;ep Silj;1' : Si i{i(MS Jr Z i L. p; SUOISIAQJ JQ SLc,14r lap ttiCIA.I V 1C as 911d CIIM)Ini do i pO cy1 �Cq Fo3da�ae pue peMeIAa1 uaaq ar c u o;aJay r ax1;}e sBulMeip eq j 131131 C32 Od1J V 3H1 213d t1 t ' t1 NI C3 i^N SV ❑ Sit 3+� COA1nOH11M E11LJ333V desion eno ineers J QZ ZO W f— 2P O � Q O 4:7)CO N a_ 0 o1�co, N, � o 0 Ico— L" w22 cc Z CC 0 06 U --Q _ ic- inJ N ce W p W or` LL O 1 LLJ 0 z 0 —J rn LU 0 W �L W Lam. W c CZ U L� uL �_ 5 a Oo� W Lf F— //w z r� 0 0 JOB NO F66991 DRAWN 11-1B86 CHECKED ISSUED REVISED 998 ACC; 589 SHEET 1 1 r •, City of Tukwila Fire Department Gary VanDusen Mayor Hubert H. Crawley Fire Chief Cartland Alarm 30459 Military Road South Federal Way, Wa. 98003 Re: Equitec - 509 Industry Drive, #12 Dear Sir: January 16, 1987 The fire alarm system plans affixed hereto have been reviewed and accepted as meeting or exceeding minimum requirements of the City of Tukwila Fire Department, Bureau of Fire Prevention, with the following notes: 1. Maintain square foot coverage of detectors per manufacturer's specifications in all areas including; closets, elevator shafts, top of stairwells, etc. (NFPA 72A, 1-2.2 & NFPA 72E) 2. Wire shall be in conduit or be UL listed Fire Protective Signaling Circuit Cable. (NFPA 72A, 2-2.1) 3. Remote indicator lights are required on all above ceiling smoke detectors. 4. A rechargeable battery back-up is required on any fire alarm installation. There shall be enough battery capacity to run the alarm system in standby for twenty-four (24) hours and, after that time, sound all alert devices for at least five (5) minutes. (NFPA 72A, 2-3.4.2) 5. All restrooms, kitchens, laundry rooms, boiler rooms or any room where there is apt to be moisture, shall have fixed temperature heat detectors installed. These detectors should have replaceable links for testing purposes. 6. A satisfactory contract covering the maintenance, operation and efficiency of the system shall be provided by the property owner. The contract shall provide for periodic inspection and tests, for proper maintenance service, and for service following operation of the system and shall be acceptable to the authority having jurisdiction. (NFPA 72A, 1-2.4.1) 7. Audible sigal devices shall be installed to indicate City of Tukwila Fire Department, 444 Andover Park East, Tukwila, Washington 98188 (206) 575-4404 City of Tukwila Fire Department Page number 2 Gary VanDusen Mayor Hubert H. Crawley Fire Chief a fire alarm condition. They shall be so located that their operation will be heard clearly, regardless of the maximum noise level. (NFPA 72A, 2-5.4) 8. All devices, combination of devices, appliances and equipment installed shall be listed for the protective signaling purpose for which they are used. (NFPA 72A, 1-2.2) The above items are a general synopsis of requirements for Fire Alarm Systems required by City Ordinance *1327, and are not intended to detail all requirements of NFPA *72. Final approval is subject to the fulfillment of requirements of NFPA *72 and a successful functional test accomplished by the installer (witnessed by the Fire Department) upon completion of the system. Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. File F.P.O. Peterson slj City of Tukwila Fire Department, 444 Andover Park East, Tukwila, Wasfdngton 98188 (206) 575-4404 a '1eAoadde uor;eao;saa ao uMop onus aoi ssaappe loexe pue 90 ) oN ue La 0-gL5 113 @seetd 1N31,1118Vd313 381d V1tMx f11 13 siyll;o anI;e�uasaadaa a �fq uor oadsupi -plan o;;oefgns si aoue;daaoe lewd sBuiMeap pasinaa do iewwgnsaa a aainbaa tJIM pue acur;deoae sty; pion him a;ep anie sPuiMeap °say; o; suolsrnaa JO suoi;alap 'suot41ppV ;dao aai j e iM n �o 4t3 ayl /to pe deooeue I , 1 a uaaq antiantio;aaay pexule s&utMeapayl 831131 a3HOV11V 31-11 83 038 NI 03101-V 0 S1N3WWO3-1.flOH1,M 0 G31d333V J r flesign e nu ineers MILITARY ROAD SO 0 O corn o }" 3 ch to J N 0 • CC • ki ti LL� LU t`-- 0 W 0 509 INDUST-ZY PRCTIEC f i1)N UJ LL z 0 JOB NO 886991 DRAWN 12-1-86 CHECKED ISSUED REVISED 9y9 ACC: 590 SHEET I • 1 2 •C L E Z+PJ (1V3 If18 NOIIN3A321d 3x13 Timm. A8 rafiff453vs flesion en ineers L7 FI 1 190' O L 9 N ti ti N • at 15 Ca LYi 0 rv • zartie 7 1Z I F f 110.1111.. ACCEPTED CI WITHOUT C3MMEWS AS NOTED IN RED The drawings affixed hereto hlve peen reviewed and accepted by tne City of Tukwila Fire Dept Alliti3ns, or revisions to these drA viigs aft, date will void this Jf n r.n .1 /ill require a resubmittal re,/,4eJ Final acceptance is sa5je:t to fiz,1 1 inspection by es edresentative tnis department - • Please call 575-4407 and give this job No 877035 and exact address for shut. down or restoration approval. DATE (5 BY *CITY OF ILA 575 440/ 0 0 JOB N0886991 DRAWN1-2-87 CHECKED ISSUED REVISED -00" ACC: 592 SHEET Gary VanDusen Mayor Hubert H. Crawley Fire Chief Cartland Alarm 30459 Military Road South Federal Way, Washington 98003 March 3, 1987 Re: Equitec - 509 Industry Drive Bldg. #16 Dear Sir: The fire alarm system plans affixed hereto have been reviewed and accepted as meeting or exceeding minimum requirements of the City of Tukwila Fire Department, Bureau of Fire Prevention, with the following notes: 1. Maintain square foot coverage of detectors per manufacturer's specifications in all areas including; closets, elevator shafts, top of stairwells, etc. (NFPA 72A, 1-2.2 & NFPA 72E) 2. Wire shall be in conduit or be UL listed Fire Protective Signaling Circuit Cable. (NFPA 72A, 2-2.1) 3. Local UL Central Station supervision is required. (City Ordinance *1327) 4. Remote indicator lights are required on all above ceiling smoke detectors. 5. Alarm circuits shall be arranged so that the occurrance of a single break or single ground fault will be indicated by a distinctive trouble signal. (NFPA 72A, 2-4.1) 6. A rechargeable battery back-up is required on any fire alarm installation. There shall be enough battery capacity to run the alarm system in standby for twenty-four (24) hours and, after that time, sound all alert devices for at least five (5) minutes. (NFPA 72A, 2-3.4.2) 7. All restrooms, kitchens, laundry rooms, boiler rooms or any room where there is apt to be moisture, shall have fixed temperature heat detectors installed. These detectors should have replaceable links for testing purposes. 8. Remote larm & trouble annunciation indication is Cly of Tukwila Fire Department, 444 Andover Park East, Tukwila, Washington 98188 (206) 575-4404 City of Tukwila Gary VanDusen Mayor Fire Department Page number Hubert H. Crawley 2 Fire Chief required if the control panel is not visible from the main entrance. (NFPA 72A, 2-4.4.1) 9. A satisfactory contract covering the maintenance, operation and efficiency of the system shall be provided by the property owner. The contract shall provide for periodic inspection and tests, for proper maintenance service, and for service following operation of the system and shall be acceptable to the authority having jurisdiction. (NFPA 72A, 1-2.4.1) 10. Audible signal devices shall be installed to indicate a fire alarm condition. They shall be so located that their operation will be heard clearly, regardless of the maximum noise level. (NFPA 72A, 2-5.4) 11. All devices, combination of devices, appliances and equipment installed shall be listed for the protective signaling purpose for which they are used. (NFPA 72A, 1-2.2) 12. Maintenance and/or replacement of automatic fire detectors shall be the responsibility of the building or unit owner or his agent. Assure that all smoke detectors are operable. (City Ordinance *1327) Please provide this office with written documentation of the last inspection conducted on the automatic fire detector units. The ,above items are a general synopsis of requirements for Fire Alarm Systems required by City Ordinance *1327, and are not intended to detail all requirements of NFPA *72. Final approval is subject to the fulfillment of requirements of NFPA *72 and a successful functional test accomplished by the installer (witnessed by the Fire Department) upon completion of the system. Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. File ncd City of Tukwila Fire Department, 444 Andover Park East, Tukwila, Washington 98188 (206) 575-4404 c. Aa •4. 1 RECEIVED TUKWILA FIR MENTION B flesion en ineers ACCEPTED 0 WITHOUT COMA^1CNTS AS NOTED IN REO PER THE AITAC-IED EVER The drawings affixed er t°e C e been reviewed and accepted, ?� a,t r t�►s Tuk�i13 Fire Dept Add►t►ins, del:tions or revisions to tnese .ara44 n3 u� ill date will void acceptan require a resubmittal or re^{ i rv►ngs Final acceptance is sub l` inspection by a representauje of this department TUKWILA FIRE DEPARTM Please cat 575.4407 and give Ar� 2� 3 -- No ! 6 and exact address for shut. down or restoration approval, zon£ 501-Y Ze)Nt 3 JOB N0886991 DRAWN c —16-87 CHECKED ISSUED REVISED 1002 ACO 593 SHEET 4 21 FLon¢. cf,Ett" l } i 1 El F Pu LL STA ® FNXED TEM'. ® RtTt. rr Kitt 53'7 1 SmnKE INET BEtn i.4JCE,LIn�� �I II boo E. L3uZZt_R �j —{Epi I— TERM( WIT -11\1a DEVICE 1 r GOLfliD FLoOR 313' M desion eno ineers 0 O cc >- cc I0 0 RE�!V+ OCT 7 198 TUKWILA FIRE PREVENTION BL JOB NO 86699 DRAWN q-2 9 -SAO CHECKED ISSUED REVISED SHEET ZGPUE 7 RQnn1 Finkle!. 1 0---1I CJ t7--;? Q------ 17— D ---0 Ci-�---�1--Ci----CF--E1ril U BLDG #3 2"d- FLocR 18/2- FRtim LowEQ nfs!►eE. 5 ZD N E B ZONE T P s R 3-5 P R P 2-3 R ZoNE5 2-1 4-5 L1-(0 4 F F 8-10 11 P R 7 & P-10 12-14 F 11 ZONE Ii ZONE R 2-3 F R. 12-13 S 15-16 R tv LEO 2-3 P R •••••••••••••.T... F R 17 . 12-14 1-2.0 h. S 15 16 R s 20 F 20 21-22 2 0 n c R 5 9-12 R 12. R P F 13 Q '4 R P 1-3 14-5 -7 c T R P EOL EOL EOL EOL EDL EDL EO L EOL tleSl9n enoineers 0 0 O u O OC 0 cc(T) - C J _ } � 3 to • J N ocf•-• p W W or 11114 'L4OC-71986 JOB NO 8i3G9g1 6 QTy r ESCRIfo7 PART MO MANUF t 'TIM / CONTROL PANEL - 0i3112B RADIDNIC5_ 1 1 ENCLD5uRE Dslt9 11 - z / DUEL ' IITrERY NtaRNFn n12.?. rf 3 461ERY I2VQt..1 (ON, 0126, 11 1 COMMAND STAT/MA) 31252 11 5 LI POk ER LW L \JTERFALE 1/ b 1 BELL CIRCuITSUPERvIslo?J 91'72 1/ 7 1 OCT) RELAY 0Bi2c1 1I T 1 STLU. b781IL (\DEIY1CD ' 22 Th-IERnostnT 1356F SD2.11 10 b7 RATE of RISE b 0 1 11 1 1 1 LIRE 105°C 300 VOLT5 811R01811 1► 2 )1 If 111! 5311 Rri 132 I% 13 21 PND1OELECTRIC SmOiiE OFT 2gao 6bc-Qo 1 B .R >c 1 U k 14 /6 REr rE 1'1 NNtalCIAI`aR 15 �6 20 PIELD At ERT 80010 32 k1 INPASECa I 419 I ANIARL PULL 5TAT1aN 529 ((D1=11 ED 17 BLDG #3 2"d- FLocR 18/2- FRtim LowEQ nfs!►eE. 5 ZD N E B ZONE T P s R 3-5 P R P 2-3 R ZoNE5 2-1 4-5 L1-(0 4 F F 8-10 11 P R 7 & P-10 12-14 F 11 ZONE Ii ZONE R 2-3 F R. 12-13 S 15-16 R tv LEO 2-3 P R •••••••••••••.T... F R 17 . 12-14 1-2.0 h. S 15 16 R s 20 F 20 21-22 2 0 n c R 5 9-12 R 12. R P F 13 Q '4 R P 1-3 14-5 -7 c T R P EOL EOL EOL EOL EDL EDL EO L EOL tleSl9n enoineers 0 0 O u O OC 0 cc(T) - C J _ } � 3 to • J N ocf•-• p W W or 11114 'L4OC-71986 JOB NO 8i3G9g1 6 DRAWN 9-30 -E3& CHECKED ISSUED REVISED SHEET i a 7P' EOL. <aNE2 =ONE 6 toMTrcL thiT GRoLLt.JD FLooR 6uzzAR JOB NO 85699 I DRAWN q -29-s', CHECKED ISSUED REVISED SHEET ZbtuE 7 FQon4 PAK,EL r TI[W QT DE5CRtPT 1 LnriTRoL PA to Et 2, 1 ENCLD LRE Par ND 091(21_B Devi MANUF 1 RADiDA.1105 L 11 3 1 D\IEL 21411 R HARNESS 14 2 BATTEPI 12UDE.. �,Ak D 122 O 12( L11252 I COMMAND _5Thiltt/i/ 6 LI POWER LDOP INTERFACE 11 11 11 11 11 0125 I 1 BELL CIRCUIT SIIPERVI510ri 01/2 8 1 DM RELY 9 1 STU. 10 22 7 -PERMS -MT I35°F 1/ 67 RATE of RISE 13 114 21 i5 /6 Ib 20 17 19 LIRE 105°C 300 VOLTS !1 r, 1r 08129 !1 b?811L ROBICO s 02 /1 b01 811 Ra18� 211 RT 1s2 11 11 1/ PI DIOELECTRIC SMOKE DET REVOrE r1NNGATOR PIELD rat ERT &Dre MANUAL PULL 5TATtON 2POO B R,K bb9-o0 228 hi 521 11 AIYI ECD l)D i=N1ii_0 5 BLDG *3 2"a. FLaoR /8/1 - Fun n LowEa bffiL . • • 1 P R s P R F tZ F I-20 K R �-5 P R F 2-10 If P 1Z-14 15 P ib EOL EOL E0 L E ZONE q LEIS 1 2-3 P r 4-S F 7- $ S R P F R EDL F P 5 F R P R P 19 EOL tlesign en� ineers 30459 MILITARY ROAD SO 0 0 Co 0) 0 J N W ~ W N O) RE: r v Li BY y OCT 71986 IC,Q PRE - • JOB NO 006991 6 DRAWN 9-30 -% CHECKED ISSUED REVISED SHEET