Loading...
HomeMy WebLinkAboutPP - 539 INDUSTRY DR - UNKNOWN - PERMITS AND PLANS539 INDUSTRY DR ASSOCIATED PERMITS D98-0020 99-F-265 00-F-377 1:;3WOWS L c - ACCEPTED fi Without Comments AsNotedlnRed ❑ Per The Attached Letter These plans have been reviewed by The TukwildFire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adOpted standards and ordinances. The responsibility forthe adequacy of design rests totally with the designe . Additions, deletions or revisions to these drawin9; after this date will void this acceptance and will require a resubmittal of revised drawings forsubsequent Vproval. Final acceptance is subject to field test and inspection b� The Tukwila Fire Prevention Bureau. rata9/if/f 9 By: TUKWILA FIRE DEPARTMENT Please call: 575.4407 and give this job No. Jia and exact address for shut- down or restoration apdroval. 1 c\V° 0 co 06eXP sa4Esutokz kSkb Nalc�c.. ?.Gt : ac44,-1 Giag1,PPcicciP : fl 1 S394 FILE Z.1 w,! Cp \- we Co�'cu9 2(4 2 I c ,A +,r. twstLYe Ct co ,t Figr@EWM D�1 Alit; ` 3 iggq . mala CT.+,T.C1 C nnnor 1HH:U l?1-1 Tc:TI F,f, ?t--nr WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE F INITIATING CIRCUIT TWO *18 FPL/THHN RED (JACKET) S SIGNALING CIRCUIT - AUDI❑ TWISTED PAIR W/ SHIELD #14 FPL RED/BLACK CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. WIRE DESIGNATION 1. ALL WALL -MOUNTED AUDIBLE & VISUAL SIGNALING APPLIANCES SHALL HAVE THEIR HEIGHTS ABOVE THE FINISHED FLOOR AT 80" TO BOTT❑M, NFPA 72, 1999 EDITION, ALLOWS 80"-96' FOR VISUAL DEVICES (CH. 4-4,4) AND REQUIRES A MINIMUM OF 90" TO TOP FOR AUDIBLE DEVICES OR 6" FROM CEILING, WHICHEVER IS LOWER (CH, 4-3.5). FOR SLEEPING AREAS GREATER THAN 16' (LINEAR) VISIBLE N❑TIFICATI❑N SHALL BE WITHIN 16' OF PILL❑W AND GREATER THAN OR EQUAL TO 24" FROM CEILING TO TOP OF LENS FOR 110cd (CH. 4-4.4.3.2) 2. ALL EQUIPMENT SHALL BE U.L. LISTED. 3. ELECTRICAL CONTRACTOR SHALL FURNISH ACCESS PANELS TO AREAS THAT REQUIRE SERVICING, TROUBLE SHOOTING, ETC. 4, DO NOT DEVIATE FROM CONDUIT RUNS AS SHOWN ON FLOOR PLANS WITHOUT PRIOR APPROVAL FROM SYSTEM SUPPLIER (GUARDIAN SECURITY SYSTEMS, INC.,TEL (206)622-6545). FACTORS SUCH AS EXCESSIVE VOLTAGE DROP, ADDITI❑NAL PARTS, ENGINEERING, ETC., THAT ARE A RESULT OF CONDUIT RUN DEVIATIONS SHALL BE THE SOLE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. 5. DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIR -FLOW, NOR CLOSER THAN 3 FEET (900rmr1) FROM AN AIR SUPPLY DIFFUSER. 6. ALL FAN SHUTDOWN FUNCTIONS, DAMPER CLOSURES, AND ASSOCIATED MECHANICAL SYSTEM FIRE ALARM INTERFACE SHALL BE BY MECHANICAL CONTRACTOR. 7, ALL DUCT SMOKE DETECTORS SHALL BE MOUNTED BY THE MECHANICAL CONTRACTOR, ALL AIR VEL❑CITY TESTING SHALL BE PERFORMED BY THE MECHANICAL CONTRACTOR. 8. ALL 120VAC POWER REQUIREMENTS FOR THE FIRE ALARM SYSTEM SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR AND SHALL MEET ALL REQUIREMENTS OF THE AUTHORITIES HAVING JURISDICTION. 9. ALL FIRE ALARM DEVICE BACKB❑XES, FIRE ALARM TERMINAL CABINETS, GUTTERS, JUNCTI❑N BOXES, AND ASSOCIATED CONDUITS SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED, REFER TO FIRE ALARM SYMBOL LIST AND/OR MOUNTING DETAILS FOR ADDITIONAL INF❑RMATI❑N. SYSTEM SUPPLIER PROVIDED BACKBOXES SHALL BE INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. 10. SMOKE DETECTOR TESTING SHALL BE ACCOMPLISHED WITH TEST MAGNETS AS PER THE MANUFACTURER'S INSTRUCTIONS. 11. ALL WIRING, INITIATING DEVICES AND ANNUNCIATOR PANEL SHALL BE SUPERVISED TO THE PRINCIPAL POINT OF ANNUNCIATI❑N. THE FIRE ALARM CONTROL PANEL TO SUPERVISE THE ANNUNCIATOR PANEL, ALL INITIATING AND INDICATING DEVICE CIRCUITS. 12. ALL WIRING SHALL BE CUT FOR IN AND OUT. WIRING SHALL NOT BE LOOPED THROUGH DEVICES. ALL SPLICED WIRE P❑SSESING SHIELDS SHALL HAVE SHIELDS SPLICED AND TAPED TO PREVENT GROUND FAULTS. 13. P❑INT AND COMMON ANNUNCIATION AND T -TAPPING (EXCEPT SLC LOOP) ARE PROHIBITED. 14, PROVIDE 3/4" CONDUIT FROM FIRE ALARM CONTROL PANEL TO TELEPHONE BACKBOARD FOR OWNER PROVIDED CENTRAL STATI❑N M❑NIT❑RING. 15. THE ALARM SYSTEM SHALL HAVE AN AUDIBILITY OF NOT LESS THAN 15dB ABOVE AMBIENT N❑ISE LEVELS. TESTING SHALL BE ACCOMPLISHED WITH A dB METER.' 16. ALL FLOW SWITCHES SHALL BE 2 WIRE WITH N❑N-ELECTR❑NIC RETARD TYPE SIMILAR TO THE SYSTEM SENSOR MODEL "WFD SERIES" ONLY. 17. ALL DEVICES IN THE ALARM SYSTEM SHALL BE COMPATIBLE AND INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 18. FIRE ALARM SYSTEM INSTALLATI❑N COMPANY SHALL BE UL LISTED (UUJS), 19. INSTALLATI❑N SHALL BE IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE, NEC AND CONTRACT DRAWINGS 20, ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ 21. THE FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF G.S.S. TECHNICIANS 22. A SET OF INSTALLATI❑N AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY G.S.S. FIELD TECHNICIANS i 35 r / 15cd 2F S 2F (, 2F (" C 2F n EXIST, TORE RM, E 2F 2F (' 15cd �1 S 2F -2F TRAINING RM. 15cd j NolpAfrE 2F (Th -2S 339 (4C USE IF NEEDED OTHERWISE DISREGARD 15cd 2F TO NEAREST EXISTING MANUAL PULL STATION J\ -T /13 15cd s IrJ 15cd J TO NEAREST SIGNALING POWER SOURCE s AREA OF WORK BUILDING #3 FLOOR PLAN BATTERY SIZING CALCULATION NEWWWXX*NEWXWMENEXNEWXNEWX*NOC40100KWXIEWWAXNEWWWNEWWWWW*WWW*WWW*WWWWWWW* Job Nave: HALLW❑OD BUILDING #3 Panel Location: BATTERY ADD-ON Date Performed: 11-02-2001 QTY, DEVICE NAME STD-BY(Amps) ALARM(Amps) 8 STR: RSS( 15CD) 0. 0000 0, 4240 Stand -By Load = Stand -By Time = Totals = 0. 0000 0. 0000 Amps 24 Hrs. Stand -By = 0. 00 Amp*Hrs Total = Stand -By + Alarm = 0. 00 + 0.04 = 0. 04 Amp*Hrs 0, 4240 Alarm Load = 0.4240 Amps Alarm Time = 5/60 Hrs. Alarm = 0.04 Amp*Hrs Multiply by De -Rating Factor of 1. 25 ---> 0. 04 * 1. 25 = 0. 04 A( MINIMUM BATTEkY SIZE = 0.04 Anpere*Hours IE WWWWWWWXWAXWWWWXWWNEWWWWWWWWWWWNEWWWXWWWWNEWWWWWWWWWWWWWWWWWWWWWW 31( WORST CASE VOLTAGE DROP CALCULATION D Job Name: Circuit: Date Performed: HALLWO❑D BUILDING #3 STROBE CIRCUIT 11-01-2001 8 STR: RSS(15CD) at 0. 0530 Amps each = 0. 4240 Amps Total = 0. 4240 Amps Circuit Length = 261 Ft to End Wire Size = #14 AWG Circuit Load = 0. 4240 Amps Voltage = 24. 0 Volts (Ckt. Load) ) (Ckt. Length) * 21. 6 Voltage Drop = A 100% (Circular Mils) NE (Volts) ( 0. 4240 ) * ( 261 ) N 21. 6 Voltage Drop = * 100% ( 4110 ) * ( 24. 0) Voltage Drop = 2.42% wmootExwwwwwwwxwwwwwwwwmolookwx A( VOLTAGE DROP = 2. 42% QUANTITY 1� 1 2 8 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT 12/24 REMOTE POWER SUPPLY PS -12/24-8 WHEELOCK PROVIDED 66" AFF TO TOP F MANUAL PULL STATION BNG-1 NOTIFIER 4S DEEP BOX W/ 48" AFF SINGLE GANG RING TO CENTER AREA HEAT DETECTOR HD -601 NOTIFIER 4S DEEP BOX W/ CEILING 3-0 RING HEAT DETECTOR C (ABOVE CEILING) HD -601 NOTIFIER 4S DEEP BOX W/ ABOVE CEILING 3-0 RING HEAT DETECTOR E (EXISTING) EXISTING EXISTING EXISTING EXISTING FIRE ALARM STROBE RSS-2415W WHEELOCK 4S DEEP BOX NO RING 80" A.F.F. TO BOTTOM FIRE ALARM N/A JUNCTION BOX BY ELECTRICIAN 4S BOX VERIFY IN U.O.N. FIELD FATC FIRE ALARM N/A TERMINAL CABINET BY ELECTRICIAN 18 x 18 x 6 VERIFY IN U.O.N. FIELD A.F.F. ABOVE FINISHED N/A FLOOR N/A N/A N/A EEL. END OF LINE RESISTOR N/A N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.D.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A VL • FAX (206) 628-4990 TEL. (206) 622-6545 VERIFY L❑CATI❑N IN FIELD N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A SYMBOLS LEGEND (+) FROM CONTROL PANEL (-) (+) FROM FCPS ( ) SMOKE/HEAT TDETECTORS E❑LR E❑LR ALARM WIRING DIAGRAMS JUNCTION BOX MOUNTED ON CEILING SLAB PREVI❑US DEVICE 11 0 0 0 F-' EAT DETECTOR JUNCTI❑N BOX MOUNTED AGAINST CEILING SUPPORT lCDl SMOKE/HEAT DETECfT❑R TO N SUSPENDED ILLUMINATED CEILING GOICE/HEAT MOUNTING DIAGRAM 4S DEEP BOX W/ 4S EXTENSION BOX CFP �j Without Comments As Noted In Red El Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city nrceptance is subject to errors and is11-olieMich do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: I /, 5y o ° By: 3eccev Cei/,A/ j 76---c7-CCs SHRH be smC.. -ePc/3-ca 411 H T (L's 6 .(c c&/' Lv,'1 Swn 0 Ice. 4" SQUARE DEEP BACK BOX WITH 1G TRIM RING fKWILA FIRE DEPARTMEN4 RI@ago call: 575-4407 Nid give this job Na,aa -T377 qnd exact address for shut. CiQ14Gr,1. Orr restoration approval, HEIGHT REQUIREMENTS PULL STATION - STROBE WALL MOUNTED DEVICE MOUNTING ELEVATION 3 NOV ' 3 2000 GENERAL NOTES SYSTEM CALCULATIONS MOUNTING DIAGRAMS Copyright 2000 by Guardian Security Systems, Inc. All Rights Reserved z 0 uJ Q co 0 SCALE: uJ DESCRIPTION O z EDEN SYSTEMS w J F - w LL DRAWN BY: MSH r4DESIGNED BY: FRANK CLOSE "DATE: 11/01/00 p OB NUMBER: 52780 SHEET FA- 01