HomeMy WebLinkAboutPP - 12214 45TH AVE S - RONDOS RESIDENCE - PERMITS AND PLANS12214 45TH AVE S
ASSOCIATED PERMITS
16-S-050 D15-0226
SITE LOCATION
CITY OF TUKWILA
FIRE MARSHAL'S OFFICE
206-575-4407
FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
King Co. Assessor's Tax No.: 017900-0693
Site Address: 12214 45TH AVE S, TUKWILA, WA 98178 Suite Number: n/a Floor: all
Tenant Name: New Tenant? ❑ - Yes ❑ - No
Property Owner's Name: RONDOS, SAM
Mailing Address: 10816 - 42ND AVENUE SW. SEATTLE WA 98146
City State Zip
CONTACT PERSON -if there are questions about the submittal.
Name: Ben Bernard Day Telephone: 425-271-5598
Company Name: Moore Fire Protection
Mailing Address: 14401 Issaquah -Hobart Rd SE ste 201 Issaquah WA 98027
City State Zip
E-mail Address: Ben@moorefire.com Fax Number:
Contractor's City of Tukwila Business License number:
Total number of new/relocated devices or sprinkler heads: 15
Valuation of Project (contractor's bid price): $ 4250.00
Scope of Work (please provide detailed information): Installation of an Automatic Fire Sprinkler system in
a new single family residence.
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature: Date:
Print Name: Day Telephone:
Plan Permit Ann doe
5/27/14 TF11 FP Form R
2 -
INSPECTION
NUMBER
INSPECTION RECORD
Retain a copy with permit
lb -S-ow
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
206-575-4407
Project:R--6-'5
b 0
Type of Inspection: �^
�j�17( f /� n/
Address.
Suite #: CZZ jQ"4-54't` .
Contact Person:
Special Instructions:
Phone No.:
I 1 Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
5
„/kc.€ -,a_ ,�> Nb -r ii-Pe►kv1- 6
i i i
ff./
4
)yz t N iu (;42- yteo-) of o -t -v-- S T*f a- ci
-
E0
It2- (71 k•J IS 4,-/4-u..- 04-f"-.
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector: f/
c--4-
Date: 2k_444/
His.:
/
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word/Inspection Record Form.Doc
3/14/14
T.F.D. Form F.P. 113
V
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
T15- — OZz4
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
206-575-4407
Project: owe
Ty of Insp ctio
dico ‘.0 e.,.---
Address:kie
/
Suite #: /n-/V�47 gyL 5.
Contact Persot
Special Instructions:
Phone No.:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Sprinklers:
/D;o5- ,4� s� �.�'e 6. �'
o
-- GvAl J lei— �71- a
/. cis'
Permits:
Occupancy Type:
a,%/0 -- Ze 34-1�1:0- � �� ,- 41e, i�
c�/d
.-- /447 Aci e`7-7 Si/.e
' _.--2--'- A7, -e, Wie,4 A-0:10, 6wt-7.1We`
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
1
Inspector:li 13/43
Date:`4/f946
Hrs.: Z 0
/
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word/Inspection Record Form.Doc
3/14/14
T.F.D. Form F.P. 113
-71:
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
206-575-4407
Project: 1Q 1/.1 Dos��Type
of Ins .
ona��� a
✓vCi fif rt
Address:
Suite#:/7- ��
�j'�j/��.
Contact Person:f�
I
Special Instructions:
Phone No.:
Approved per applicable codes.
riCorrections required prior to approval.
COMMENTS:
Sterni 1cl un, Pi.o9'v nifffzdvb-3
Needs Shift Inspection:
,p
Sprinklers:
Date: 3 f
Fire Alarm:
tfe3
I
Flood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy
pe: _
r
Inspector:'
4—
Date: 3 f
/, -7...-
Hrs.:
I
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word/Inspection Record Form.Doc
3/14/14
T.F.D. Form F.P. 113
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
o 9.6 6
- s — 656
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
206-575-4407
Project:
o v✓ `D (� .�
Sprinklers:
Typej�vers ZACf Inspection:
, b " co
0700
Address: AD a / q
Suite #:
ei5-f--1-/
Contact Person:
Occupancy Type:
Special Instructions:
Phone No.:
_clapproved per applicable codes.
nCorrections required prior to approval.
COMMENTS:
Qu C161- — ems' ,
dte
OK -
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector:^ (---7
Date: /%/jeb.
Hrs.:
X100.00 REINSPECTION FEE REQUIRED. Yo II receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word/Inspection Record Form.Doc
3/14/14
T.F.D. Form F.P. 113
ERE
FIRE PROTECTION
RONDOS RESIDENCE
NFPA 13D SFR DESIGN
12214 45TH AVE S
TUKWILA, WA 98178
HYDRAULIC CALCULATIONS &
MATERIAL SPECIFICATIONS
14401 Issaquah -Hobart Rd. Suite 201 (425) 271-5598 State Contractor's License
Issaquah WA 98027 Fax: (425) 369-6899
# MOOREFP116NP
Hydraulic Overview
Job Number: Rondos Residence
Report Description: Residential 2 Head Calc
Job
Job Number
Rondos Residence
Design Engineer
Ben Bernard
Job Name: ---
Rondos Residence
Phone —
425-271-5598
FAX --
425-369-6899
Address 1
12214 45TH AVE S, TUKWILA, WA 98178
State Certification/License Number
MOOREFP116NP
Address 2
AHJ
TUKWILA FIRE MARSHAL
Address 3
Job Site/Building
Rondos Residence
System
Density
0.050gpm/ft2
Area of Application
648.00ft2
Most Demanding Sprinkler Dale
4.9 K -Factor 16.97 at 12.000
Hose Streams
0.00
Coverage Per Sprinkler
324.00ft2
Number 01 Sprinklers Calculated
2
System Pressure Demand
39.425
System Flow Demand
34.15
Total Demand
34.15 @ 39.425
Pressure Result
+110.569 (73.7%)
Supplies
Check Point Gauges
Node Flow(gom) Hose Flowlaaml Static(psil Residual(psi)
Identifier Pressure(psi) K-Factor(K1 Flow(gpm)
1 8000.00 150.000 20.000
9
WASHINGTON STATE
CERTIFICATE OF COMPETENCY
FIRE PROTECTION SPRINKLER SYSTEMS
Tracy Moore
SePct3l oorFie Protection
MOOREFP116NP
-xj1(rk(� 17xpiras
Slynoture Date 12/31/15
A
ENG_ 20160307_Rondo_DWG _Work.cad
Supply at Node 1 (8000.00, 0.00, 150.000, 20.000)
200 —
180
160
O
140
Static
Pressure
150.000
\,
120
6
.y
a =
100
=
0 =
to =
80
li _
60
15
@ 39.425
=System
20
demand
curve
I
0
11111111111111111111111111111111
111111111
111111111
111111111
111111111
art 3200 4000 4800 5600 6400 7200 8000
Water flow, gpm
at 41 \A C o rAn L...
. d A..L.Coo1NI VtOt %too ..o 4 44
AO /AO Mr. C O.COS)C AAA
O 4
111
Hydraulic Summary
Job Number: Rondos Residence
Report Description: Residential 2 Head Calc
Job
Job Number
Rondos
Residence
Residence
Design Engineer
Ben Bernard
Job Name:
Rondos
State Cenif tion/LIcense Number
MOOREFP116NP
Address
12214 45TH
Address 2
Address 3
AVE S, TUKWILA, WA 98178
AHJ
TUKWILA FIRE MARSHAL
Job Site/Building
Rondos Residence
—
-- - -
Drawing Name
ENG_20160307_Rondo_DWG_Work.cad
System
Remote Area(s)
Most Demanding Sprinkler Data
4.9 K -Factor 16.97 at 12.000
Occupancy : Job Suffix
Residential Manually Flowing
Hose Allowance At Source
0.00
Density Area of Application
0.050gpm/ft2 648.00ft2
Additional Hose Supplies
Node
Flow(apml
Number OySprinklers Calculated Coverage Per Sprinkler
2 324.00ft2
AutoPeek Results: Pressure For Remote Area(s) Adjacent To Most Remote Area
Total Hose Streams
0.00
I
I
Total Water Required (Including Hose
34.15
Alowance)
System Flow Demand
34.15
Maximum Pressure Unbalance In Loops
0.000
Maximum Velocity
14.09 between
Maximum. Velocity
Volume capacity
22.95ga1
Above Ground
nodes 1 and 52
Under Ground
of Wet Pipes
I
I
Vaowme capacity of Dry Pipes
Supplies
Node
Hose Flow
(gpm)
Static
(psi)
Residual
(psi)
@
Flow Available @ Total Demand ' Required
(gpm) (psi) (gpm) (psi)
Safety Margin
(psi)
1
150.000
20.000
8000.00 I 149.995 i 34.15 1 39.425
110.569_
Contractor
Contractor Number
MooreFire
Contact Name
' Tracy V Moore
Contact Title
President
Name of Contrectoe-
Moore Fire
__— -_
Protection
-Hobart Rd SE
WA, 98027
—F Phone - _--. _.
425-271-5598
Extension
-
Address 1
14401 Issaquah
Address 2
Issaquah
Address 3
FAX
' 425-369-6899
----
E-mail
• TracyVMoore@moorefire.com
Web -Si . —
, ts
moorefire.com
— —
Summary Of Outflowing Devices
Job Number: Rondos Residence
Report Description: Residential 2 Head Calc
Device
Actual Flow
(gPm)
Minimum Flow
(gam)
K -Factor I Pressure
(K) (psi)
c> Sprinkler
Sprinkler
101
102
16.97
17.17
c> Most Demanding Sprinkler Data
16.97
16.97
+ 4.9
4.9
12.000
12.281
11e
Node Analysis
Job Number: Rondos Residence
Report Description: Residential 2 Head Calc
Node
Elevation(Foot) Fittings
Pressure(psi)
Discharge(gpm)
1t
101
102
S
10'-8'/, Spry 12.000) _
11-7% Spr(-12.281)
— 9
15
18
12'-1 T(5'-0)
10'-1 T(6'-11)_
10'-1 i T(5'-0)
-F
23
26
27
28
29
30
34
52
12'-4 T(5'-0)
-3'-0 �9
0'-6 GIoV(-0.000)
0'-10 T, Tr(1-0)
1'-2
2'-6 BFP(-5.193),
4'-5'14
-3'-0 WMV- 2.578
39.425 34.15
12.000 ± 16.97
12.281 + 17.17
12.351
16.195
16.203 _r
12.272 +
28.673
26.783
4-
26.625 26.625
26.357
25.667
19.473
33.132
110
Hydraulic Analysis
Job Number: Rondos Residence
Report Description: Residential 2 Head Calc
Pipe Type Diameter Flow
Velocity
K -Factor
HWC
Friction Loss
i Length
i Eq. Length
i Total Length
Pressure
Summary
Downstream Elevation Discharge
Upstream
Pt
_
Pn Fittings
GI Route 1
DR 1.1010 16.97
5.72
150
12.000
12.272
0.050231
7'-6%
12'-0
19'-63/.�
Pf
Pe
Pv
0.983
-0.711
101 10'-81h 16.97
23 12'4
4.9
Sprinkler,
E(7'-0), T(5'-0)
BL 1.1010 18.98
6.40
150
0.061781
28'-10
19'-0
47'-1c
Pf
Pe
Pv
2.956
0.975
23 12'-4
18 10'-1
12.272
16.203
2E(7'-0), T(5'-0)
BL 1.3940 34.15
7.18
150
16.203
19.473
0.058007
8'-2'/:
6'-0
14'-21/
Pf
Pe
Pv
0.823
2.448
18 10'-1 15.16
34 4'-5Y.
Flow (q) from Route 2
T(6'-0)
FM _ 1.4080 34.15
7.04
120
0.083489
1'-11'%
1'-11%
Pf
I Pe
Pv
5.354
0.840
34 4'-5%
30 Z-6
19.473
25.667
2f(-0.000), BFP(-5.193)
FR 1.4080 34.15
7.04
120
0.083489
1'-4
1'-4
Pf
Pe
Pv
0.111
0.578
30 2'-6
29 1'-2
25.667
26.357
FR 1.2650 34.15
8.72
150
0.093080
0'-4
1'-0
1'-4
Pf
Pe
Pv
0.124
0.145
29 1'-2
28 0'-10
26.357
26.625
Tr(1'-0)
FR _ 1.5050 34.15
6.16
150
0.039943
0'-4
0'-4II
Pf
I Pe
Pv
0.013
0.145
28 0'-10
27 0'-6
26.625
26.783
GIoV(-0.000)
FR 1.5980 34.15
5.46
150
0.029828
3'-6'
9'-00
12'-6
Pf
Pe
Pv
0.373
1.517
27 0'-6
26 -3'-0
26.783
28.673
E(9'-0)
BL 1.5980 34.15
5.46
150
0.029828
53'-1
10'-0
63'-1I
Pf
Pe
Pv
4.459
26 -3'-0
52 -3'-0
28.673
33.132
E(9'-0), cplg(1'-0), WMV(-2.578)
BL 0.9950 34.15
14.09
150
0.299668
21'-0
21-0
Pf
Pe
Pv
6.293
52 -3'-0
1 -3'-0
_
33.132
39.425
Supply,
0.00
Hose Allowance At Source
1
1 34.15
o Route 2
DR 1.1010 17.17
5.79
150
0.051317
0'-6
5'-011
5'-6
Pf
Pe
Pv
0.282
-0.211
102 11'-7% 17.17
9 12'-1
4.9
12.281
12.351
Sprinkler,
T(5'-0)
BL 1.1010 15.16
5.11
150
0.040764
46'-11'/x'
26'-0i
72'-11%
Pf
Pe
Pv
2.974
0.870
9 12'-1
15 10'-1
12.351
16.195
T(5'-0), 3E(7'-0)
BL 1.3940 15.16
3.19
150
0.012919
0'-7
0'-7
Pf
Pe
Pv
0.008
15 10'-1
18 10'-1
16.195
16.203
Ili Route 3
BL 1.1010 2.01
0.68
150
0.000969
7'-8;
19'-0
26'-8,
Pf
Pe
Pv
0.026
-0.106
9 12'-1
23 12'-4
12.351
12.272
2E(7'-0), T(5'-0)
Equivalent Pipe Lengths of Valves and Fittings (C=120 only)
C Value Multiplier
/ Actual Inside Diameter
\ 4'87
= Factor
Value Of C 100 130 140
Multiplying Factor 0.713 1.16 1.33
150
1.51
Schedule 40 Steel Pipe Inside Diameter
J
Hydraulic Analysis
Pipe Type
Downstream
Upstream
Diameter
Elevation
Flow
Discharge
Job Number: Rondos Residence
Report Description: Residential 2 Head Calc
Velocity HWC
K -Factor Pt Pn
Friction Loss
Fittings
Length I Pressure
Eq. Length Summary
Total Length
Pipe Type Legend
Units Legend
Fittings Legend
AO Arm -Over Diameter
BL Branch Line Elevation
CM Cross Main Flow
DN Drain Discharge
DR Drop Velocity
DY Dynamic Pressure
FM Feed Main Length
FR Feed Riser Friction Loss
MS Miscellaneous HWC
OR Outrigger pt
RN Riser Nipple Pn
SP Sprig pf
ST Stand Pipe Pe
UG Underground Pv
Inch
Foot
gpm
gpm
fps
psi
Foot
psi/Foot
Hazen -Williams Constant
Total pressure at a point in a pipe
Normal pressure at a point in a pipe
Pressure loss due to friction between points
Pressure due to elevation difference between indicated points
Velocity pressure at a point in a pipe
ALV
AngV
b
BaIV
BFP
BV
C
cplg
Cr
CV
DeIV
DPV
E
EE
Eel
Ee2
fd
FDC
fE
fEE
flg
FN
fT
g
GIoV
GV
Ho
Hose
HV
Hyd
LtE
mecT
Noz
P1
P2
PIV
PO
PRV
PrV
red
S
sCV
Spr
St
T
Tr
U
WirF
WMV
z
Alarm Valve
Angle Valve
Bushing
Ball Valve
Backflow Preventer
Butterfly Valve
Cross Flow Turn 90°
Coupling
Cross Run
Check Valve
Deluge Valve
Dry Pipe Valve
90° Elbow
45° Elbow
11W Elbow
22'/z Elbow
Flow Device
Flex Drop
Fire Department Connection
90° FireLock(TM) Elbow
45° FireLock(TM) Elbow
Flange
Floating Node
FireLock(TM) Tee
Gauge
Globe Valve
Gate Valve
Hose
Hose
Hose Valve
Hydrant
Long Turn Elbow
Mechanical Tee
Nozzle
Pump In
Pump Out
Post Indicating Valve
Pipe Outlet
Pressure Reducing Valve
Pressure Relief Valve
Reducer/Adapter
Supply
Swing Check Valve
Sprinkler
Strainer
Tee Flow Turn 90°
Tee Run
Union
Wirsbo
Water Meter Valve
Cap
ii
Hydraulic Graph
\Job Number: Rondos Residence
Report Description: Residential 2 Head Calc
Supply at Node 1
200
180
160
140
Static
Pressure
150.000
120
2.
100
a)
2
a`
80
60
40 _34.15
39 425
7System
20
demand
curve
a
0—num
!mum
mum'iilii((((
(((((iii(
111111(((
111111111
IIi((iiia
!mit i(i
9300 1600 2400 3200 4000 4800 5600 6400 7200 8000
Water flow, gpm
itiaraulm Goon
Supply at Node 1
Slabs: Pressure
150.000
Reeare Pressure
20.000 @ 8000.00
Available Pressure at Tree of Test
149.995 @ 34.15
SyolerDecub - - - ----
39.425 @ 34.15
SYeba Denn.ed (Including Mose Allowance at Source) — ---
39.425 @ 34.15
IN
Flow Diagram (Isometric View)
Job Number: Rondos Residence
Report Description: Residential 2 Head Calc
Family Room
RISE 1" X 1'-0" TO
VAULTED CEILING ABOVE.
RISE 11/4" X 91-1'
TO FLOOR ABOVE.
z
i1
11 RISER LOC,
SEE DETAIL/T
f1
11
11
11
0
1'/2" POLY UG
CONTINUES APPROX.
36' TO 1" DOM/FIRE
METER.
Vault Ends Here
ulted
g Room.
Vaulted
Living Room
MAIN FLOOR PLAN
io -o
SCALE: 1/4" = 1' - 0j
Bedroom#3
Bedroom #2
RISE 11/4" X 9'-1"
FROM FLOOR BELOW.
Master Bed
UPPER FLOOR PLAN
SCALE: 1/4" = 1' - 0"i 10'-0
A LIST OF APPROVED PRODUCTS FOR USE WITH BLAZEMASTER CPVC
PIPE IS INCLUDED WITH THE PRODUCT SPECIFICATIONS BOOKLET. FOR
A COMPLETE AND UP-TO-DATE PRODUCT SEARCH, PLEASE GO ONLINE TO
<http://www.lubrizol.com/CPVC/ChemicalCompatibilityFinder.html>
CLOUD DENOTES: 2 MOST DEMANDING HEADS
IN A SINGLE COMPARTMENT CALCULATED AT
18'-0" X 18'-0" SPACING.
MIN. REQUIRED FLOW: 17 GPM PER HEAD.
SYSTEM PRESSURE DEMAND: 1.10.4 PSI.
EXCESS PRESSURE: 39.6 PSI.
fr �I DSA
Hon:, aag.06-575-4407
4O7
Ois this Fire Permit No.
::moi exact address for shut-
s3ww fn Or. ntstarglArm tappaml
HYDRAULIC
SYSTEM.
LOCATION:
NO. OF SPRINKLERS:
COVERAGE. PER. SPRINKLER:
DESIGN DENSITY:
RE
FIRE PROTECTION,
RONDOS. RESIDENCE
2
324
.05
AREA OF DISCHARGE:
GPM DISCHARGE:
RESIDUAL PRESSURE
AT BASE OF RISER:
STATIC PRESSURE:
648
34.3
110,4
150.0
MOORE FIRE PROTECTION
14401 ISSAQUAH-HOBART RD,
ISSAQUAH, WA. 98027
(425) 271-5598 FAX (425) 295-1788
Without Comments
A
Per.i.he L- Atta hed .0l :.e8
The plans `11 'v ' ` °' viewed by, The 'I ikvvita Fire
Prevention Bure!y.I ._ . ! 'nrmance with current City
standards. subject to *;r`.'ors and
orni5Sion, -1,,,otorhhe violations ,r adopted
standards 3n_ %r _�f. :t..... I e respansibil ,, for the
a , iu icy of de: a! :..,tally with•! the designer.
nFer.
dj ?, ,Ons; (Jeiett. ). I.5moi ? iy to these drawirKrzi safer
this dat...i and Mil !`quer a
resubmittal submittal of re i .:iJ sags for subsequent approval.
Final acceptance is .sut ext to field test and Inspection by
The Tukwila Fice P, ven4'on rsureau.
)4.1.4ka t l et-1c•1o"- i f P C leolu ,
147 aro trGti„t
) revA, ), •
6.I I
MIN. R-7 INSULATION BATT. OVER PIPE
SS IF BLOWN IN
Mir6�➢'•.
SPRINKLE'; BRANCH LINE
' —UNIT SPACEPENDANT SPRINKLER HEAD
TYP. ATTIC INSULATION DETAIL
SCALE: NONE11
PLUMBER TO
LEAVE 11/4"
MALE
THREADED
ADAPTER
1'-0" AFF
AND 0'-6"
FROM WALL.
9
P.m%
10
11
1
12
WET PIPE RISER DETAIL
SCALE: NONE
WET RISER ASSEMBLY LIST
NO.
ITEM
1
11/z" POLY UG RAN FROM NEW 1" DOM/FIRE METER
2
11/2" MAIN SUPPLY SHUTOFF
3
11/2" TEE SPLIT TO DOMESTIC LINE
4
DOMESTIC BALL SHUTOFF BY OTHERS
5
11/2" TYPE L COPPER PIPING BY OTHERS
6
11/2" APOLLO DC4A DOUBLE CHECK VALVE ASSEMBLY
7
1122" DYNA-THREAD PIPING WITH C.I. FITTINGS
8
POTTER MODEL VSR-SG FLOW SWITCH W/ RETARD
9
300# WATER GAUGE WITH 1/2"X 1/4" BUSHING
10
1" COMBINATION MAIN DRAIN INSPECTOR'S TEST
11
1" X 1/2" GALV. 45 PIPED TO EXTERIOR OF BUILDING
12
BROKEN SPKR. HD. TO SIMULATE SPKR. FLOW
MAXIMUM SUPPORT SPACING.
FOR CPVC PIPING
PIPE SIZE: FEET
3/4"
1-1/4"
1-1/2"
2
5-1/2;
6
6-1/2
7
8
METER
(1.7)
(1.8)
(2.0)
(2.1)
(2.4)
Hanger No. 23.
pipe Strap
Wood Screw #18 x.1.5
Pipe
Pipe. Strap
///// /'/// /'///.
/ / / /"
Wood Joist or Beam
Hanger FIG.# 28M
Stand-off Pipe Hanger
Pipe
Wood Screw
#18 X 11/2"
Standoff
Pipe Hanger
-Wood Joist, Beam or Deck,
TYP.FIG #23 CPVC HANGER DETAIL TYP.FIG #28M CPVC HANGER DETAIL
SCALE: NONE SCALE: NONE
AH,3: TUKWILA FIRE MARSHAL
NFPA 13D (2013 ED.) SYSTEM DESIGN
MAX. RES. PENDENT HD. SPACING
18'-0" X 18'-0" 324 SQ.FT. PER HD. TOTAL MAX.
PARCEL NO. 017900-0693
LEGAL DESCRIPTION
ALLENTOWN ADDITION TO SEATTLE LOT 4 EXC N 10.50 FT TGW ALL OF LOT 5; TGW LOT 6 EXC S 5:25
FT THEREOF (AKA PARCEL "B" CITY OF TUKWILA LOT CONSOLIDATION NO L12-020 RECORDING NO
20130222900001)
NOTES:
RESIDENTIAL SPRINKLERS ON THIS PROJECT ARE CALCULATED ATA MAXIMUM 18'-O" X 18'-0" SPACING
UNLESS OTHERWISE NOTED.
NO RESIDENTIAL SPRINKLERS ARE TO BE MORETHAN 9'-0" OFF WALLS.
NO RESIDENTIAL'SPRINKLERS' IN TH `SAME COMPARTMENT ARE TO BE MORE THAN 18'-0" APART
MAXIMUM.
NO RESIDENTIAL SPRINKLERS ARE TO BE CLOSER TOGETHERTHAN 8'-0"' MINIMUM.
ALL CPVC PIPE IS. TO BE SUPPORTED PER MANUFACTURER'S SPECIFICATIONS AND.IS TO: BE SECURED TO
PREVENT LATERAL. MOVEMENT PIPE IS TO BE SECURED TO PREVENT SPRINKLER HEAD MOVEMENT
ALL CPVC WET SYSTEM PIPING LOCATED IN ATTIC SPACES AND EXTERIOR WALLS SHALL BE PROTECTED
FROM EXPOSURE TO FREEZING TEMPERATURES WITH BATT TYPE INSULATION (MIN.R-7) INSULATION IS TO
PROVIDE ADEQUATE PROTECTION ABOVE / OUTSIDE, THE PIPING AND IS TO BE SECURED TO PREVENT THE
ACCUMULATION OF INSULATION BETWEEN THE HEATED BUILDING CAVITY AND THE SPRINKLER PIPING.
BLOWN. IN TYPE INSULATION IS NOT ACCEPTABLE FOR THIS. PURPOSE. ALL INSULATION AND ITS
INSTALLATION IS TO BE BY OTHERS.
MOORE FIRE PROTECTION'S WARRANTY OF WORK DOES NOT COVER ANY DAMAGE DUE TO .FREEZE RELATED
PROBLEMS. PIPING IS. TO BE MAINTAINED AT40 DEG. MINIMUM AT ALL TIMES BY OTHERS.
MOORE FIRE PROTECTION. SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO
ADEQUATELY SUPPORT THE FIRE. SPRINKLER SYSTEM OR. ANY APPURTENANCES THEREOF'
OWNER IS RESPONSIBLE FOR THE PERIODIC INSPECTION,. TESTING AND MAINTENANCE OF THE WATER
BASED FIRE PROTECTION SYSTEM(S) IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 25.
8.3 LOCATION OF SPRINKLERS
8.3.1: SPRINKLERS SHALL BE INSTALLED IN ALL AREAS WITH THE FOLLOWING EXCEPTIONS`:
8,3.2: SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS -OF 55 SQ.FT: AND LESS,
8.3.3: SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES 24 SQ.FT OR LESS
WHERE THE LEAST DIMENSION DOES NOT EXCEED 3'-0 AND THE WALLS AND CEILING ARE SURFACED WITH.
NONCOMBUSTIBLE OR LIMITED COMBUS-i:IBLE MATERIALS AS, DEFINED IN NEPA-220.
8.3.4: SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES, OPEN ATTACHED PORCHES, CARPORTS, AND SIMILAR
STRUCTURES.
8.3.5: SPRINKLERS SHALL. NOT BE REQUIRED IN ATTICS, PENTHOUSE EQUIPMENT ROOMS, ELEVATOR MACHINE ROOMS,
CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT,
FLOOR/CEILING SPACES, ELEVATOR SHAFTS, CRAW;LSPACES AND OTHER CONCEALED SPACES NOT USED OR INTENDED FOR
LIVING PURPOSES.
8.3.6: SPRINKLERS SHALL NOT BE REQUIRED IN COVERED, UNHEATED PROJECTIONS OF THE BUILDING AT ENTRANCES/EXITS
AS LONG AS THE DWELLING UNIT HAS ANOTHER MEANS OF EGRESS.
8.3.7: SPRINKLERS SHALL. NOT BE REQUIRED FOR CEILING POCKETS OF 1.00 CUBIC FEET OR LESS WHERE THE FLOOR UNDER.
IS PROTECTED.
8.3.8: SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR CLOSETS WHERE THERE ARE, NO
DOORS OR UNPROTECTED PENETRATIONS INTO'. THE. DWELLING UNIT.
45TH AVE S
1"TAP
11/2" POLY UG
1" DOM/:FIRE METER
SL PPLY' MAIN
0
RISER LOCATION
SITE PLAN
SCALE: NONE.
PAID
MAR 1C 21116
TUKWILA FIRE
- 2f7o"" 3 e5-2 si
DRAWING NO.
U -
Ll.
0
T—I
Revisions
Head Count
LI)
1-1
0
160 DEG F
155 DEG F
TYCO LFII RES. QR. WHITE CONC. SSP K=4.9
TYCO LFII QR. WHITE SEMI-REC HORZ. SW K=4.2
TOTAL HEADS FOR PROJECT:
State license
1mo®mi.®nmos■
ummnom
CO
F LI N
WI-rc
ze JV ��_O
pow 2((0
xwomUar
z 0 2 cc Q
w(91So0
CO 2 2 S.
0
4C
Q
ce
E --
ca
O Ni
00
ZCi
CY
(
H
1-4
O Q
Ln
co
co
r
rn
0,6
N
!r)
N
Ch
�o
�o
Is1 E
ln'Ua
w
ow
.0
U' z
C a
U w
,-;(13 O.
ink
Parcel: 017900-0693
0
Lu
O
N
Q
<
B. BERNARD
C)
MaLU