HomeMy WebLinkAboutPP - 14411 45TH LN S - RESIDENCE - PERMITS AND PLANS14411 45TH LN S ASSOCIATED PERMITS 17-S-248 D17-0080 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 0 0 4 0 0 0 0 3 9 7 Site Address: 14411 45th lane south Tukwila Suite Number. Floor: Tenant Name: 1 of 3 New Tenant? ❑ - Yes ❑ - No Property Owner's Name: MJM HOMES LLC Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Mike Hutchinson Day Telephone: 253-381-4456 Company Name: Evergreen Fire Protection Mailing Address: PO BOX 998 Puyallup 98371 City State Zip E-mail Address: Evergreenfirepro@msn.com Fax Number: 253-252-7943 Valuation of Project (contractor's bid price): $ 5000.00 Scope of Work (please provide detailed information): new NFPA 13D fire sprinkler system 27 PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: \ Y Signature: " " Print Name: Mike Hutchinson Plan Permit App.doc Day Telephone: Date: 12/13/2017 253-381-4456 5/14/10 TFD FP Form 8 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: teyfr3 J ( Type of Inspectio • .i4ed Address: Suite #: (44'ft / t. ( C • Contact Person: Special Instructions: 7 Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: �r r� ro",�i Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:M Date: /46/ /( Hrs.: 1 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T,F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit / 7 -S —4.3-Y2- DI-1-0080 �-YZ DIS-0080 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: ���� // 4,...e.0Type / 'lil/lG� of Inspection: -- - C -ova Address:f� #: � Wff 7 LSV. tSuite Contact Person: Special Instructions: Permits: Phone No.: Approved per applicable codes. riCorrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: /��JGli'7- — PAs5ed &c••.g , .5=1 6 Z 4/1--0-4 17164(A5 Xtd‘e, -tr.e( ,i.i.( ,‘.- /� #/ /6 71-1%pe,-2 J v - Pilt55 0 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Vi ` S� Date: 2/7/f Hrs.: / _ v $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 DATE: 12/17/2017 C:\HASS CALCS\3 lots Multani Tukwills.rdf Page 1 EVERGREEN FIRE PROTECTION, INC. 10509 64th AVENUE E PUYALLUP,WA 98373 RESIDENTIAL SPRINKLER SYSTEM HYDRAULICS CALCULATION REPORT FOR Lot 3 Multani Tukwilla 14411 45th lane south Date: 12/17/2017 File No: Data File Name: 3 lots Multani Tukwills.rdf SPRINKLER SPACING 256.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 16.0 ft. Min. Dist. Bet. Spklrs: 8.0 Max. Dist. Spklr. to Wall: 8.0 ft. SPRINKLER SPECIFICATIONS Mfr: Reliable Descr: RA0612 RFC43 Fl Conc .Pend.(16x16) K=4.30 Calculated K Factor for Arm -Overs & Drops: 1.0 ft. x 1.101 in. Drop: K=4.26 (Incl. 1 Tee) 0.0 ft. x 1.101 in. Arm -Over: K=4.25 (Incl. 1 Tee & 1 Ell) PIPE SPECIFICATIONS Type: CPVC S-40 HWC: 150 WATER SUPPLY Source: Public Test Date: By: Static: 60.0 psi Resid: 0.0 psi Flow: 0.0 gpm Public Main Size: 0 in Domestic Demand: 0.0 gpm at node number 0 SPRINKLER DEMAND No.Spklrs. Min Spklr. Press. Node Total Avail. Req'd Flowing Flow (psi) No. Flow Press. Press. 1 13.0 9.3 1 13.0 60.0 32.2 2 13.0 9.3 1 26.3 60.0 41.2 REVIEWING AUTHORITY City of Tukwilla DATE: '12/17/2017 C:\HASS CALCS\3 lots Multani Tukwills.rdf Page 2 WATER SUPPLY CURVE 60.0 A CC 54.0 P 48.0 R E S 42.0 S 36.0 U R E 30.0 ( 24.0 P 18.0 S I 12.0 6.0 CB CD 0.0 1 I I 1 1 1 1 1 1 04 8 12 16 20 24 28 32 36 40 FLOW (GPM) Static = 60.0 psi (fixed pressure) (1 sprinkler flowing) (2 sprinklers flowing) A = Available Water Supply 60.0 psi @ 13.0 gpm B = Required Water Supply 32.2 psi @ 13.0 gpm C = Available Water Supply 60.0 psi @ 26.3 gpm D = Required Water Supply 41.2 psi @ 26.3 gpm DATE: 12/17/2017 C:\HASS CALCS\3 lots Multani Tukwills.rdf Page 3 RESULTS OF ANALYSIS NFPA NODE & PIPE DATA 1 Sprinkler Flowing Node Tag Elevation Node Type Pressure Discharge Notes (FT) (PSI) (GPM) 1 20.0 K= 4.26 9.3 13.0 3 20.0 10.1 4 20.0 11.9 5 10.0 16.6 6 10.0 16.8 7 0.0 21.6 8 0.0 26.6 9 0.0 27.1 10 0.0 SOURCE 32.2 2 20.0 10.1 Pipe Tag K-fac AF AF to L C (Pt) Frm Node El (ft) PT (q) node/ Nom ID Fit F (Pe) Notes To Node El (ft) PT TF(Q) disch Act ID T FL/FT (Pf) Pipe: 1 4.26 2R: 2 20.00 150 10.1 3 20.0 10.1 13.0 Disch 1.000 B: 5 7.00 0.0 1 20.0 9.3 13.0 1.101 27.00 0.031 0.8 Pipe: 3 0.00 B: 5 36.00 150 11.9 4 20.0 11.9 13.0 1 1.000 2L:10 20.00 0.0 3 20.0 10.1 13.0 1.101 5R: 5 56.00 0.031 1.7 Pipe: 4 0.00 10.00 150 16.6 5 10.0 16.6 13.0 3 1.000 B: 5 5.00 4.3 4 20.0 11.9 13.0 1.101 15.00 0.031 0.5 Pipe: 5 0.00 1.00 150 16.8 6 10.0 16.8 13.0 4 1.000 B: 5 5.00 0.0 5 10.0 16.6 13.0 1.101 6.00 0.031 0.2 Pipe: 6 0.00 10.00 150 21.6 7 0.0 21.6 13.0 5 1.000 3R: 3 3.00 4.3 6 10.0 16.8 13.0 1.101 13.00 0.031 0.4 Pipe: 7 0.00 1.00 150 26.6 8 0.0 26.6 13.0 6 1.000 0.00 0.0 7 0.0 21.6 13.0 1.101 1.00 0.031 5.0 Fixed Pressure Loss Device: 5.00 psi Pipe: 8 0.00 80.00 150 27.1 9 0.0 27.1 13.0 7 1.500 4L:28 28.00 0.0 8 0.0 26.6 13.0 1.598 108.00 0.005 0.5 Pipe: 9 SOURCE 1.00 150 32.2 10 0.0 32.2 13.0 8 1.000 0.00 0.0 9 0.0 27.1 13.0 1.101 1.00 0.031 5.0 Fixed Pressure Loss Device: 5.00 psi Pipe: 10 0.00 5.00 150 10.1 3 20.0 10.1 0.0 1.000 B: 5 5.00 0.0 DATE: 12/17/2017 C:\HASS CALCS\3 lots Multani Tukwills.rdf Page 4 2 20.0 10.1 0.0 1.101 10.00 0.000 0.0 RESULTS OF ANALYSIS NFPA NODE & PIPE DATA 2 Sprinklers Flowing Node Tag Elevation Node Type Pressure Discharge Notes (FT) (PSI) (GPM) 1 20.0 K= 4.26 9.3 3 20.0 10.1 4 20.0 16.5 5 10.0 22.5 6 10.0 23.2 7 0.0 29.0 8 0.0 34.1 9 0.0 36.1 10 0.0 SOURCE 41.2 2 20.0 K= 4.26 9.8 13.0 13.3 Pipe Tag K-fac AF AF to L C (Pt) Frm Node El (ft) PT (q) node/ Nom ID Fit F (Pe) Notes To Node El (ft) PT TF(Q) disch Act ID T FL/FT (Pf) Pipe: 1 4.26 2R: 2 20.00 150 10.1 3 20.0 10.1 13.0 Disch 1.000 B: 5 7.00 0.0 1 20.0 9.3 13.0 1.101 27.00 0.031 0.8 Pipe: 3 0.00 13.3 2 B: 5 36.00 150 16.5 4 20.0 16.5 13.0 1 1.000 2L:10 20.00 0.0 3 20.0 10.1 26.3 1.101 5R: 5 56.00 0.113 6.3 Pipe: 4 0.00 10.00 150 22.5 5 10.0 22.5 26.3 3 1.000 B: 5 5.00 4.3 4 20.0 16.5 26.3 1.101 15.00 0.113 1.7 Pipe: 5 0.00 1.00 150 23.2 6 10.0 23.2 26.3 4 1.000 B: 5 5.00 0.0 5 10.0 22.5 26.3 1.101 6.00 0.113 0.7 Pipe: 6 0.00 10.00 150 29.0 7 0.0 29.0 26.3 5 1.000 3R: 3 3.00 4.3 6 10.0 23.2 26.3 1.101 13.00 0.113 1.5 Pipe: 7 0.00 1.00 150 34.1 8 0.0 34.1 26.3 6 1.000 0.00 0.0 7 0.0 29.0 26.3 1.101 1.00 0.113 5.1 Fixed Pressure Loss Device: 5.0 psi Pipe: 8 0.00 80.00 150 36.1 9 0.0 36.1 26.3 7 1.500 4L:28 28.00 0.0 8 0.0 34.1 26.3 1.598 108.00 0.018 2.0 Pipe: 9 SOURCE 1.00 150 41.2 10 0.0 41.2 26.3 8 1.000 0.00 0.0 9 0.0 36.1 26.3 1.101 1.00 0.113 5.1 Fixed Pressure Loss Device: 5.0 psi DATE: '12/17/2017 C:\HASS CALCS\3 lots Multani Pipe: 10 3 20.0 2 20.0 4.26 10.1 9.8 Legend: PT - Total Pressure at Node Fl - Flow rate (gpm) L - Pipe Length F - Fitting Length T - Total Length of Pipe 13.3 Disch 13.3 Tukwills.rdf 5.00 150 1.000 B: 5 5.00 1.101 10.00 0.032 C - Hazen -Williams Coefficient FL/FT - Friction Loss per Foot Pt - Total Pressure Loss Pe - Elevation Pressure Loss Pf - Friction Pressure Loss Page 5 10.1 0.0 0.3 Fitting Code Letters: E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, S=SwgChk, G=GatV1v, X= X, Y= The maximum velocity of water flow occurs in pipe 6 at 4.38 ft/s with 1 sprinkler flowing. The maximum velocity of water flow occurs in pipe 6 at 8.88 ft/s with 2 sprinklers flowing. PIPE FITTINGS TABLE Pipe Table Name: standard.npt PAGE: C MATERIAL: CPVC S-40 HWC: 150 Diameter Equivalent Fitting Lengths (in) E L B R C 45 Ell 90 Ell TeeBch TeeRun Couplg 1.101 1.00 5.00 5.00 1.00 1.00 1.598 2.00 7.00 8.00 1.00 1.00 in Feet S G SwgChk GatVly 8.00 2.00 14.00 3.00 X Y z X Y z 0.00 0.00 0.00 0.00 0.00 0.00 A negative value for flow rate indicates the direction of flow A Fixed Pressure Loss Device calcualtes as a positive friction A Fire Pump calculates as a negative friction loss is from the second, pipe n loss Sprinkler system has been hydraulically calculated with the HASS HOUSE 3.7.0 computer program (License No. R609099990) to provide an average imbalance of 0.010 gpm at each node and a maximum imbalance of 0.05 gpm with one sprinkler flowing, and 0.010 gpm at each node and maximum imbalance of 0.06 gpm with 2 sprinklers flowing in accordance with NFPA 13 and 13D or 13R. The minimum source pressure is 20.0 psi with a minimum required pressure of 41.2 psi and a 7 minute flow of 184 gal. and a 10 minute flow of 263.5 gallons. The minimum pressure at any node is 9.3 psi at node 1. HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 DATE:112/17/2017 C:\HASS CALCS\3 lots Multani Tukwills.rdf • EVERGREEN FIRE PROTECTION, INC. 10509 64th AVENUE E PUYALLUP,WA 98373 RESIDENTIAL SPRINKLER SYSTEM HYDRAULICS CALCULATION REPORT FOR Lot 3 Multani 9' single sprinkler Tukwilla 14411 45th lane south Date: 12/17/2017 File No: Data File Name: 3 lots Multani Tukwills.rdf SPRINKLER SPACING Page 1 324.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 18.0 ft. Min. Dist. Bet. Spklrs: 8.0 Max. Dist. Spklr. to Wall: 9.0 ft. SPRINKLER SPECIFICATIONS Mfr: Reliable Descr: RA0612 RFC43 F1 Conc .Pend.18x18) K=4.30 Calculated K Factor for Arm -Overs & Drops: 1.0 ft. x 1.101 in. Drop: K=4.26 (Incl 1 Tee) 0.0 ft. x 1.101 in. Arm -Over: K=4.25 (Incl 1 Tee & 1 Ell) PIPE SPECIFICATIONS Type: CPVC S-40 HWC: 150 WATER SUPPLY Source: Public Test Date: By: Static: 60.0 psi Resid: 0.0 psi Flow: 0.0 gpm Public Main Size: 0 in Domestic Demand: 0.0 gpm at node number 0 SPRINKLER DEMAND No.Spklrs. Min Spklr. Press. Node Total Avail. Req'd Flowing Flow (psi) No. Flow Press. Press. 1 18.0 17.9 1 18.0 60.0 44.2 1 18.0 17.9 1 18.0 60.0 44.2 REVIEWING AUTHORITY City of Tukwilla DATE:`12/17/2017 C:\HASS CALCS\3 lots Multani Tukwills.rdf • WATER SUPPLY CURVE Page 2 60.0 54.0 P 48.0 R E S S U R E ( P S I 0D 42.0 36.0 30.0 24.0 18.0 12.0- 6.0 0.0 1 1 I I 1 I 1 1 1 I 02 4 6 8 10 12 14 16 18 20 FLOW (GPM) Static = 60.0 psi (fixed pressure) (1 sprinkler flowing) (1 sprinklers flowing) A = Available Water Supply C = Available Water Supply 60.0 psi @ 18.0 gpm 60.0 psi @ 18.0 gpm B = Required Water Supply D = Required Water Supply 44.2 psi @ 18.0 gpm 44.2 psi @ 18.0 gpm DATE:'12/17/2017 C:\HASS CALCS\3 lots Multani Tukwills.rdf RESULTS OF ANALYSIS NFPA NODE & PIPE DATA 1 Sprinkler Flowing Node Tag Elevation Node Type Pressure Discharge Notes (FT) (PSI) (GPM) 1 20.0 K= 4.26 17.9 3 20.0 19.4 4 20.0 22.5 5 10.0 27.7 6 10.0 28.0 7 0.0 33.1 8 0.0 38.1 9 0.0 39.1 10 0.0 SOURCE 44.2 18.0 Page 3 Pipe Tag K-fac AF AF to L C (Pt) Frm Node El (ft) PT (q) node/ Nom ID Fit F (Pe) Notes To Node El (ft) PT TF(Q) disch Act ID T FL/FT (Pf) Pipe: 1 4.26 2R: 2 20.00 150 19.4 3 20.0 19.4 18.0 Disch 1.000 B: 5 7.00 0.0 1 20.0 17.9 18.0 1.101 27.00 0.056 1.5 Pipe: 3 0.00 B: 5 36.00 150 22.5 4 20.0 22.5 18.0 1 1.000 2L:10 20.00 0.0 3 20.0 19.4 18.0 1.101 5R: 5 56.00 0.056 3.1 Pipe: 4 0.00 10.00 150 27.7 5 10.0 27.7 18.0 3 1.000 B: 5 5.00 4.3 4 20.0 22.5 18.0 1.101 15.00 0.056 0.8 Pipe: 5 0.00 1.00 150 28.0 6 10.0 28.0 18.0 4 1.000 B: 5 5.00 0.0 5 10.0 27.7 18.0 1.101 6.00 0.056 0.3 Pipe: 6 0.00 10.00 150 33.1 7 0.0 33.1 18.0 5 1.000 3R: 3 3.00 4.3 6 10.0 28.0 18.0 1.101 13.00 0.056 0.7 Pipe: 7 0.00 1.00 150 38.1 8 0.0 38.1 18.0 6 1.000 0.00 0.0 7 0.0 33.1 18.0 1.101 1.00 0.056 5.1 Fixed Pressure Loss Device: 5.00 psi Pipe: 8 0.00 80.00 150 39.1 9 0.0 39.1 18.0 7 1.500 4L:28 28.00 0.0 8 0.0 38.1 18.0 1.598 108.00 0.009 1.0 Pipe: 9 SOURCE 1.00 150 44.2 10 0.0 44.2 18.0 8 1.000 0.00 0.0 9 0.0 39.1 18.0 1.101 1.00 0.056 5.1 Fixed Pressure Loss Device: 5.00 psi DATE:'12/17/2017 C:\HASS CALCS\3 lots Multani Tukwills.rdf RESULTS OF ANALYSIS NFPA NODE & PIPE DATA 1 Sprinklers Flowing Node Tag Elevation Node Type Pressure Discharge Notes (FT) (PSI) (GPM) 1 20.0 K= 4.26 17.9 18.0 3 20.0 19.4 4 20.0 22.5 5 10.0 27.7 6 10.0 28.0 7 0.0 33.1 8 0.0 38.1 9 0.0 39.1 10 0.0 SOURCE 44.2 Page 4 Pipe Tag K-fac AF AF to L C (Pt) Frm Node El (ft) PT (q) node/ Nom ID Fit F (Pe) Notes= To Node El (ft) PT TF(Q) disch Act ID T FL/FT (Pf) Pipe: 1 4.26 2R: 2 20.00 150 19.4 3 20.0 19.4 18.0 Disch 1.000 B: 5 7.00 0.0 1 20.0 17.9 18.0 1.101 27.00 0.056 1.5 Pipe: 3 0.00 B: 5 36.00 150 22.5 4 20.0 22.5 18.0 1 1.000 2L:10 20.00 0.0 3 20.0 19.4 18.0 1.101 5R: 5 56.00 0.056 3.1 Pipe: 4 0.00 10.00 150 27.7 5 10.0 27.7 18.0 3 1.000 B: 5 5.00 4.3 4 20.0 22.5 18.0 1.101 15.00 0.056 0.8 Pipe: 5 0.00 1.00 150 28.0 6 10.0 28.0 18.0 4 1.000 B: 5 5.00 0.0 5 10.0 27.7 18.0 1.101 6.00 0.056 0.3 Pipe: 6 0.00 10.00 150 33.1 7 0.0 33.1 18.0 5 1.000 3R: 3 3.00 4.3 6 10.0 28.0 18.0 1.101 13.00 0.056 0.7 Pipe: 7 0.00 1.00 150 38.1 8 0.0 38.1 18.0 6 1.000 0.00 0.0 7 0.0 33.1 18.0 1.101 1.00 0.056 5.1 Fixed Pressure Loss Device: 5.0 psi Pipe: 8 0.00 80.00 150 39.1 9 0.0 39.1 18.0 7 1.500 4L:28 28.00 0.0 8 0.0 38.1 18.0 1.598 108.00 0.009 1.0 Pipe: 9 SOURCE 1.00 150 44.2 10 0.0 44.2 18.0 8 1.000 0.00 0.0 9 0.0 39.1 18.0 1.101 1.00 0.056 5.1 Fixed Pressure Loss Device: 5.0 psi DATE:" 12/17/2017 C:\HASS CALCS\3 lots Multani Tukwills.rdf Legend: PT - Total Pressure at Node Fl - Flow rate (gpm) L - Pipe Length F - Fitting Length T - Total Length of Pipe C - Hazen -Williams Coefficient FL/FT - Friction Loss per Foot Pt - Total Pressure Loss Pe - Elevation Pressure Loss Pf - Friction Pressure Loss Page 5 Fitting Code Letters: E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, S=SwgChk, G=GatVly, X= X, Y= The maximum velocity of water flow occurs in pipe 8 at 6.08 ft/s with 1 sprinkler flowing. The maximum velocity of water flow occurs in pipe 5 at 6.07 ft/s with 1 sprinklers flowing. PIPE FITTINGS TABLE Pipe Table Name: standard.npt PAGE: C MATERIAL: CPVC S-40 HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly 1.101 1.00 5.00 5.00 1.00 1.00 8.00 2.00 1.598 2.00 7.00 8.00 1.00 1.00 14.00 3.00 X Y X Y 0.00 0.00 0.00 0.00 z z 0.00 0.00 A negative value for flow rate indicates the direction of flow is from the second pipe n A Fixed Pressure Loss Device calcualtes as a positive friction loss A Fire Pump calculates as a negative friction loss Sprinkler system has been hydraulically calculated with the HASS HOUSE 3.7.0 computer program (License No. R609099990) to provide an average imbalance of 0.015 gpm at each node and a maximum imbalance of 0.14 gpm with one sprinkler flowing, and 0.010 gpm at each node and maximum imbalance of 0.07 gpm with 1 sprinklers flowing in accordance with NFPA 13 and 13D or 13R. The minimum source pressure is 20.0 psi with a minimum required pressure of 44.2 psi and a 7 minute flow of 126 gal. and a 10 minute flow of 180.0 gallons. The minimum pressure at any node is 17.9 psi at node 1. HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 ' `,1 • 1 ..1 ALL PIP 8' MAX , 0 9'MA)11 ETO BE PRI KLER C F WALLS WI TH FF WALLS W TH1 • GREAT ROOM PVC UNLESS OTHEWISE \OTED. VERAE TO BE 16' X 16' H 2 SPRINKLERS OR MODE WITHIN C00.?6\RTMENT RE AHSINGLE SPRI\KLE COVERS COMPARTMENT PIPE /4*, I 11 INSULATION INSULATION PRESSURE GAUGE TING DETAIL TO SYSTEM DRAIN VALVE FLOW SWITCH (WIRE TO OUTSIDE BELL) DRAIN PIPED' TO EXTERIOR 1" AMES 2000B BACKFLOW PREVENTER (10) To domestic piping 1.5" 80' NTS IFR RIS -R CHE I I ! ! . I i I 1 • 1 , 1 i i : 1 I 1 i I './4• --- -• --• - ---- --.k.,7741•1./W//( .4":'.7•1 .,07 1 • 1 z., 1 • 1 / I 2, I ! I ,,,...:___L:„.„•,_„i___..,,____,,J,_._.:=4,,.•_-.....,..., I ' , s ,,.• 1 11 1 p / i , 91\I\G •:;!,„!..• • :;.! - 1" WATER METER EN- GARAGE AI\ FLOOR 1/4".1'-o" LA\ Aff.M7.007/7;f6701 / BE900 kr, g 1 / 1 i A I, ,,C hi 1 ____......_. 7 .,;4,/,,,,,,,,/ ,f;„:„.;,.,_„:„:„?..,:‘,,,:i7..„.1,4,,,,,,„:„,,-2,,,,,,,,,,,,f„,z,,,,„.„7„,/z,../47..7„;•„,,,,„ .,. / 1 , 0 , 1=.!.w......—=,...., r---- ---71 iI. /\ •,' , .1., , ..;, ,...,:l . .....1 . / o %/. ESI 1 HEA. /21./Atv AV,/ 3 VIA/ /AV 4 ,„. 0 M 7. /MY .420107.40:4140//17/7/ AZY /41 /4 .7% •;%.' „4:037/...0AYMM3F657-4M/Z.ZZI EMMY AsiV.06•2Z4V ./4 4iN agartzemoslawdmr:eamosmose J reareasommra• 'arc .demew A MEDIA ROOM Arffiff.1211 Wear, UPE FLO PLA 1 / 4" =1 -0" General Notes Sprinkler Symbol Legend 1. OWNER TO PROVIDE ADEQUATE HEAT (40'F. MIN) TO PREVENT SPRINKLER PIPES FROM FREEZING. 2. OWNER TO PROVIDE HARD WIRED HOME SMOKE DETECTION SYSTEM. 3. CPVC PIPE SHALL HAVE HANGERS 6'-0" c\c AND NOT MORE THAN 6" FROM ANY SPRINKLER HEAD, 4. ALL ATTIC PIPING TO BE TENTED WITH BATT INSULATION TO PREVENT FREEZING. 5. ALL PIPING TO BE 1" C.P.V.C. U.N.O. SYM SPRINKLER ORIFICE SIZE, TYPE & FINISH QUAN TEMP K FACTOR • RELIABLE RFC 43 16'x16' 2 head flow requirement 26 GPM 0 9.6 psi 25 155' 4.3 RELIABLE F1 RES 49 16'x16' FLOW REQUIREMENT 26 GPM @ 9.6 psi 155' 4.9 RELIABLE F1 RES 44 SIDEWALL 16' X 20' 155' 4.4 VICTAULIC DRY UPRIGHT ' 200' 5.6 Reliable F 3 QR DRY Sidewall 155' 5.6 TOTAL 27 EVEGEE\ FRE POTECTIO\ PO BOX 998 Puyallup, WA 98371 evergfp967Iz Phone: (253) 252-7942 DATE: 12/12/2017 REV: DRAWN: MH SHEET: I\C 1 OF1 • I. 1 Li lot 2 south lot 3 south 144 Tukwila 14411 Tukwila Lot 5 14419 45th south Tukwila. J4/0.• 0 Without Comments IZC As Noted in Red 0 Per The Attached Letter These plans .have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions Which do not authorize viohtions of adopted standards anti ordinances. The responsibility for the adequacy of-desion totally withthe designer. Additions, deletions ,-(2\fisions to these drawings after this date will:void ttit;! r:Y..7ceptance and will require a resubmittal of revisP..!--. (i7awings for subsequent approval. Final accentanc€-.; ;5,j ojec.- co field test and Inspection by The Tukwil6. i-,ieyenon Bureau. Date: b- -):-71 eick)‘01- . clvo revoreol. 44 Plow C444-) -1-1)1x TUKWILA FRE DEPARTMENT Piease, :NY5•75-4.14)7 and 'y '4: P2rrit: No. for Ehut ..:own or reatorztion appoval. Sheet Title Job Title PAID .1 2017 WkWILA FIRE ---41( 2– • lane anel, 1.1 lane II:, • ,• i Stamp \F--/6\ 13D FR Lot 3 V ulc -- 111 1 5-tn lc TuKwilc WASHINOtON STATE CERTIFICATE OP COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Michael D. Hutchinson 1166-0599-EI6 Level 2 Evergreen Fire Protection, Inc. P9137LZ ure _ DLA\ nti ne south Wc. 14411 45 LN S 17-S-248