PP - 4736 S 160TH ST - RESIDENCE - PERMITS AND PLANS
4736 S 160TH ST ASSOCIATED PERMITS 19-S-038 D17-0162 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 4736 S 160th Street Suite Number: Floor: Tenant Name: (new construction) New Tenant? ❑ -Yes E - No Property Owner's Name: Maninder Khatkar Mailing Address: 7909 Pacific Hwy E Milton WA 98354 City State Zip 222304-9115 CONTACT PERSON -if there are questions about the submittal. Name: Jake Box Day Telephone: (307) 251-1701 Company Name: Glacier Fire Protection, LLC Mailing Address: PO Box 7980 Bonney Lake WA 98391 jakeb@glacierfp.com City State Zip E-mail Address: Fax Number: N/A NICET III number: Erin Clayton 7544-0817-C Business Liceontractor's nse numberof : 0998044 Total number of new/relocated devices or sprinkler heads: 40 Valuation of Project (contractor's bid price): $12'700.00 Scope of Work (please provide detailed information): Design & install fire sprinkler system in new constructed 1 family dwelling per NFPA 13D. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. PAID BUILDING OWN Signature: R AUTHORIZED AGENT: Print Name: J a k Box FE3 1 r, 2019 TUKWILA FIRE Date: 2/8/2019 Day Telephone: (307) 251-1701 Plan Permit App.doc 8/22/14 TFD FP Form 8 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit n-ci(0-2:N/ /9-s - 03' PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: i hC<� Sprinklers: Type of I - n9-ts Tv ^ n ' y ICtX Address:� Suite #: ""f) Z S) ( l 0 Contact Person: Special Instructions: Occupancy Type: , Phone No.: %pproved per applicable codes. nCorrections required prior to approval. COMMENTS: SP(2— valm,4 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: , Inspector: s3 Date: //j /2 z Hrs.: /. O $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 3 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit p /7_ _ a(62 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT Project: Sprinklers: Fire Alarm: Hood & Duct: Type of Inspection: �/ Monitor: Pre -Fire: Address: Suite#: -- (0 ) V�h- - ('iSr Contact Person: - Special Instructions: Phone No.: )-Approved per applicable codes. riCorrections required prior to approval. COMMENTS: Ol c 7a Cin- 77-(4-6(v62/40.7� ons 0 i/6-yu---elio Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Date: em 1/ 9 Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Z -.'1 '''' Date: em 1/ 9 Hrs.: , $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.. D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /9- 5 vsg' PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: v J ►14 0 a Ra S+ Type of Inspection: Address: A� 56 S /66 Suite#: Contact Person: Special Instructions: Phone No.: I I Approved per applicable codes. Corrections required prior to approval. COMMENTS: e (1 / L %)l �J (12 PeR—"r--t u Sz' Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: 4'7 -fkli Date: A h _4c). Hrs.: / ...� ,(.( $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the Ci of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 1 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 6.-s-d3C‘ PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: ! c, ii.l4/ fe.e.23 Type of Inspection✓Cav_ Fire Alarm: 4V Address: ! / Suite #: C.lvo Contact Person: Special Instructs ns: Phone No.: _.....--- Approved Approved per applicable codes. Corrections required prior to approval. COMMENTS: .e -z4 -4t- 7"er— A°Li a-6. Al v c,o-r- Gem% tog c O . /40.AS 7?../A GIA C 11Zr) PZ -a/1"---; et150 4 -0 -e -0/S dV /a4o (n -ce.4/t1 5g -S- 71 - Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: /2 c -- Date: j.-ziO I r1 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 FIRE SPRINKLER EQUIPMENT SUBMITTAL SUBMITTAL DOCUMENTS FOR: Khatkar Residence 4736 S 160th Street Tukwila, WA 98188 Parcel # 222304-9115 GFP JOB # 40095 SUBMITTED BY: At ve FIRE PROTECTION LLC PO Box 7980 Bonney Lake, WA 98391 (253) 501-7558 WASHINGTON CONTRACTORS LICENSE # GLA CIFP834MJ Hydraulic Overview Job Number. 40095 - 40095 Report Description: Residential (1 .>E Job Job Number 40095 Design Engineer Erin Clayton Job Name: Khatkar Residence Phone 303-551-5308 FAX Address 1 4736 S 160th St State Cedifwetbn/License Number Address 2 Tukwilla, WA 98188 AHJ Address 3 Job Site/Bulling System Density 0.05gpm/ft2 Area of Application 900ft2 (Actual 184ft2) Most Demanding Sprinkler Data 4.9 K -Factor 13.00 at 7.039 Hose Streams 0.00 Coverage Per Spreader 256ft2 Number 0/ Sprinklers Calculated 2 System Pressure Damen! 47.213 System Flow Demand 26.82 Total Demand 26.82 @ 47.213 Pressure Result +21.738 (31.5%) up It . � � check Point Gauges Node Name Flow(qpm) Hose Flow(qpm) Static(psi) Residual(psi) Identifier Pressure(osi) K-Factor(K) Flow(apm) 1 Water Supply 1500.00 68.960 52.170 40095 iCatkar Res Listing;. : Water Supply at Node 1 (1500.00, 0.00, 68.960, 52.170) 100 90 80 70 —Static Pressure 68 960 60 _ 'In – Q E 506 1500.00 @ 52.170 . co co I' 40 82 @ 47.213 a. 30 System demand curve 20 10 0 AllIffl1111111111111111111111111111111111111111111111 111111111 11111III 1 IIIIIIIII gore --boo 1200 1500 1800 2100 2400 2700 3000 Water flow, gpm ©M.E.P.CAD, Inc. AutoSPRINK 2018 v14.3.10.0 2/7/2019 1:59:14PM Page 1 �a9 Hydraulic Summary Job Number: 40095 - 40095 Report Description: Residential (1 ©M.E.P.CAD, Inc. AutoSPRINK 2018 v14.3.10.0 2/7/2019 1:59:17PM Page 2 Job Number 40095 Design Engineer Erin Clayton Job Name: Khatkar Residence State CerliflooborvLicense Number Address 1 4736 S 160th St AHJ Address 2 Tukwilla, WA 98188 Job Site/Building Address 3 Drawing Name 40095_Khatkar Res_Listing System Remote Area(s) Most Demanding Sprinkler Data 4.9 K -Factor 13.00 at 7.039 Occupancy Residential Job Suffix 40095 Hose Allowance At Source 0.00 Density 0.05gpm/ft2 Area of Application 900ft2 (Actual 184ft2) Addltlonal Hose Supplies Node Flow(gom) Number Of Sprinklers Calculated 2 Coverage Per Sprinkler 256ft2 AutoPeak Results: Pressure For Remote Area(s) Adjacent To Most Remote Area Left: 46.348 Total Hose Streams 0.00 System Flow Demand 26.82 Total Water Required (Including Hose Allowance) 26.82 Maximum Pressure Unbalance In Loops 0.000 Maximum Velocity Above Ground 9.04 between nodes 84 and 46 Maximum Velocity Under Ground Volume capacity of Vikt Pipes 951.91 gal Volume capacity of Dry Pipes Supplies Node Name Hose Flow (gpm) Static (psi) Residual Flow (psi) °@ (gpm) Available Total Demand (psi) g° (gpm) Required (psi) Safety Margin (psi) 1 Water Supply 68.960 52.170 i 1500.00 68.950. 26.82 47.213 21.738 Contractor Contractor Number Contact Name Contact Tale Name of Contractor: Phone Extension Address 1 FAX Address 2 E -mall Address 3 WebStle ©M.E.P.CAD, Inc. AutoSPRINK 2018 v14.3.10.0 2/7/2019 1:59:17PM Page 2 i3 Hydraulic Graph p . Job Number: 40095 - 40095 Report Description: Residential (1 �,l ©M.E.P.CAD, Inc. AutoSPRINK 2018 v14.3.10.0 2/7/2019 1:59:19PM Page 3 Water Supply at Node 1 100 90 80 70 —Static 60 Pressure 68.960 •a 50 1500.00 @ 52.170 2 N -26.82@47.213 2 o_ ~ 40 30 =System demand curve 20 10 _. Muuuun 111111111 111 1 11 1 11 III I 1 I 1 1 I 1 1 1 1 1 1 1 1 1 11 1 1 1 1 1 1 1 I I I I I I I I I I I I I I I I I I 1 I 1 1 I 1 1 1 1 0— 0300 600 900 1200 1500 1800 2100 Water flow, gpm 2400 2700 3000 Hydraulic Graph Water Supply at Node 1 Static: Pressure 68.960 Residual: Pressure 52.170 @ 1500.00 Available Pressure at time of Test 68.950 @ 26.82 System Demand 47.213 @ 26.82 System Demand (Including Hose Nbwance et Source) 47.213 @ 26.82 �,l ©M.E.P.CAD, Inc. AutoSPRINK 2018 v14.3.10.0 2/7/2019 1:59:19PM Page 3 Summary Of Outflowing Devices -- Job Number: 40095 - 40095 Report Description: Residential (1) Device Actual Flow (gpm) Minimum Flow (gpm) K -Factor (K) Pressure (psi) Sprinkler 236 13.82 13.00 4.9 7.957 I* Sprinkler 240 13.00 13.00 4.9 7.039 c Most Demanding Sprinkler Data © M.E.P.CAD, Inc. AutoSPRINK 2018 v14.3.10.0 2/7/2019 1:59:25PM Page 4 111 Node Analysis Job Number. 40095 - 40095 Report Description: Residential (1 Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 1 -3'-0 S 47.213 26.82 236 18'-8 Spr(-7.957) 7.957 13.82 240 18'-8 Spr(-7.039) 7.039 13.00 46 14'-5'/2 Z 17.657 47 14'-5'/: Z 17.657 84 1'-10 BFP(-4.000) 33.174 98 19'-0 T(5'-0), Tr(1'-0) 7.987 ©M.E.P.CAD, Inc. AutoSPRINK 2018 v14.3.10.0 2/7/2019 1:59:27PM Page 5 Hydrauik Analysis Job Number. 40095 - 40095 Report Description: Residential (1 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Eq. Length Total Length Pressure Summary Downstream Elevation Discharge K -Factor Pt Pn Fittings Upstream Gib Route 1 DR 1.1010 13.00 4.38 150 0.030666 15'-11 20'-0 35'-11 Pf 1.102 Pe -0.154 Pv 240 18'-8 13.00 4.9 7.039 Sprinkler, 98 19'-0 7.987 2E(7'-0), T(5'-0), Tr(1'-0) BL 1.1010 26.82 9.04 150 0.117104 49'-9 16-0 65-9 Pf 7.701 Pe 1.969 Pv 98 19'-0 13.82 7.987 Flow (q) from Route 2 47 14'-5Y2 17.657 4Tr(1'-0), E(7'-0), T(5-0), Z 1.1010 26.82 9.04 150 0.117104 0'-0 0'-0 Pf 0.000 Pe Pv 47 14'-5Y2 17.657 46 14'-5Y2 17.657 Z BL 1.1010 26.82 9.04 150 0.117104 25'-7Y2 26'-0 51'-7'/2 Pf 10.044 Pe 5.473 Pv 46 14'-5Y2 17.657 84 1'-10 33.174 2T(5'-0), 2Tr(1'-0), 2E(7'-0), BFP( -4.000) BL 1.5980 26.82 4.29 150 0.019083 92'-10 9'-0 101-10 Pf 11.943 Pe 2.095 Pv 84 1'-10 33.174 1 -3'-0 47.213 E(9'-0), WMV(-10.000), S 0.00 Hose Allowance At Source 1 26.82 Gil Route 2 DR 1.1010 13.82 4.66 150 0.034349 0'-4 5-0 5-4 Pf 0.184 Pe -0.154 Pv 236 18'-8 13.82 4.9 7.957 Sprinkler, 98 19'-0 7.987 T(5'-0) Equivalent Pipe Lengths of*Ives and Fittings (C=120 only) I C Value Multiplier Actual Inside Diameter 4 87 Value Of C 100 130 140 150 MultiplyingFactor 0.713 1.16 1.33 1.51 ( Schedule 40 Steel Pipe Inside Diameter > = Factor p $LA © M.E.P.CAD, Inc. AutoSPRINK 2018 v14.3.10.0 2/7/2019 1:59:28PM Page 6 Hydrauaysis Job Number: 40095 - 40095 Report Description: Residential (1) Pipe Type Diameter Flow Velocity HWC Friction Loss Downstream Upstream AO BL CM DN DR DY FM FR MS OR RN SP ST UG Elevation Pipe Type Legend Arm -Over Branch Line Cross Main Drain Drop Dynamic Feed Main Feed Riser Miscellaneous Outrigger Riser Nipple Sprig Stand Pipe Underground Discharge Diameter Elevation Flow Discharge Velocity Pressure Length Friction Loss HWC Pt Pn Pf Pe Pv K -Factor Pt Units Legend Pn Fittings Inch Foot gpm gpm fps psi Foot psi/Foot Hazen -Williams Constant Total pressure at a point in a pipe Normal pressure at a point in a pipe Pressure loss due to friction between points Pressure due to elevation difference between indicated points Velocity pressure at a point in a pipe ALV AngV b Ba1V BFP BV C cplg Cr CV DeiV DPV E EE Eel Ee2 fd FDC fE fEE flg FN fT 9 GIoV GV Ho Hose HV Hyd LtE mecT Noz P1 P2 PIV PO PRV PrV red S sCV Spr St T Tr U WirF WMV z Length Eq. Length Total Length Fittings Legeri Pressure Summary Alarm Valve Angle Valve Bushing Ball Valve Backflow Preventer Butterfly Valve Cross Flow Turn 90° Coupling Cross Run Check Valve Deluge Valve Dry Pipe Valve 90° Elbow 45° Elbow 11%° Elbow 22'/z Elbow Flow Device Flex Drop Fire Department Connection 90° FireLock(TM) Elbow 45° FireLock(TM) Elbow Flange Floating Node FireLock(TM) Tee Gauge Globe Valve Gate Valve Hose Hose Hose Valve Hydrant Long Turn Elbow Mechanical Tee Nozzle Pump In Pump Out Post Indicating Valve Pipe Outlet Pressure Reducing Valve Pressure Relief Valve Reducer/Adapter Supply Swing Check Valve Sprinkler Strainer Tee Flow Tum 90° Tee Run Union Wirsbo Water Meter Valve Cap ©M.E.P.CAD, Inc. AutoSPRINK 2018 v14.3.10.0 2/7/2019 1:59:28PM Page 7 SITE PLAN 0 4 8 l6 32 SCALE 1/16"-1'-0" CC ❑ Without Comments -E As Noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Ti:',wila Fire rrevention Bureau for conformance w th current City .;17.indards. Acceptance is subject to errors and ,isslons which do not authorize violations of adopted ndards and ordinances. The responsibility for the Jequacy of design rests totally with the designer. Additions, deletions Ca revisions to these drawings after t1is date will void this acceptance and will require a resubmittal Of revised drawings for subsequent approval. Final acceptance Is subject to field test and Inspection by The Tukwila Flr? Prevention Bureau. Date: a- 3-1 By:, ) 1 1 ! f4yreC.,I(,lc. )1 -flow 4-t)4- )1-v40 T UK It.A FIRE DEPARTMENT Please call 2CG-575-4407 and give this r of a Permit No. 1q -S -o3? and enact address for shut- down or restoration approval. $Y OTHERS 4736S 160TH ST TEX': GLACIER FIRE PROTECTION, LLC. TO START ABOVE 11120 ACKFLOW 2'41" AFF PROPERTY UNE NEW OUTH 160TH STREET CPVC PIPE STRAP AFCON MODEL 510 CPVC PIPE/ HEX. HEAD SELF TAPPING SCREW AFCON #905 DOUBLE FASTENER CPVC PIPE STRAP TYPICAL. HANGER DETAIL #1 SCALE : N.T.S. WOOD LAG SCREW` EXISTING UNDERGROUND AFCON #514 HANGER "- -CPVC: SPRINKLER PIPE WOOD STRUCTURE TYPICAL HANGER DETAIL #2 SCALE N.T.S. HANGER APPLICATION \RESTRAINER APPLICATION HEX HEAD SELF TAPPING SCREW CPVC PIPE SINGLE FASTENER: CPVC PIPE STRAP TYPICAL HANGER DETAIL #3 SCALE : N.T.S. GENERAL NOTES 1. THE FIRE PROTECTION SPRINKLER SYSTEM FOR THE SINGLE FAMILY DWELLING UNIT SHALL BE DESIGNED AND INSTALLED PER NFPA 13D, 2016. 2. CALCULATION FOR THE RESIDENCE SHALL BE PER NFPA 13D, 2016. 3. PIPE THROUGHOUT THE DWELLING UNIT TO BE CPVC SPRINKLER PIPING UNLESS NOTED OTHERWISE. 4. ALL HANGERS SHALL BE PLACED AND INSTALLED IN ACCORDANCE WITH NFPA 13, 2016. 5. SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 SQ.FT. AND LESS. 6. SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES THATARE LESS THEN 24 SQ.FT., THE LEAST DIMENSION DOES NOT EXCEED 3'-0 AND THE ROOM IS SURFACED WITH NONCOMBUSTIBLE OR LIMITED COMBUSTIBLE MATERIALS. 7. SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES, OPEN ATTACHED PORCHES, - CARPORTS, AND SIMILAR STRUCTURES. 8. SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS, CONCEALED SPACES, FLOOR/CEILING SPACES, CRAWL SPACES, AND OTHER CONCEALED SPACES THATARE NOT USED OR INTENDED FOR LIVING PURPOSES AND DO NOT CONTAIN FUEL -FIRED EQUIPMENT. 9. WIRING OF ANY NEW DEVICES IF REQUIRED IS BY OTHERS. 10. PAINTING AND LABELING OF PIPING IF REQUIRED IS BY OTHERS. FIRE SPRINKLERS SHALL NOT BE PAINTED OVER. 11. IT SHALL BE: THE OWNERS RESPONSIBILITY TO MAINTAIN THE TEMPERATURE ABOVE 40° AT ALL TIMES. 12. A MAIN DRAIN IS TO BE PROVIDED AND INSTALLED IN ACCORDANCE WITH NFPA-13D. HUB DRAINS TO BE PROVIDED BY OTHERS AS NEEDED. 13. NO GYP. BD. CEILINGS SHALL BE INSTALLED UNTIL ROUGH VISUAL INSPECTION IS COMPLETE. 14. MAXIMUM RESIDENTIAL PENDANT SPRINKLER SPACING COVERAGE 16'-0 x 16'-0. MAXIMUM DRY SIDEWALL SPRINKLER HEAD SPACING 14-0 X 14-0. MAXIMUM RESIDENTIAL DRY SIDEWALL SPRINKLER HEAD SPACING 16-0 X 20'-0. 15. MINIMUM RESIDENTIAL PENDANT SPRINKLER SPACING 8'-0 O.C. MINIMUM DRY SIDEWALL SPRINKLER SPACING 6-00.C. MINIMUM RESIDENTIAL DRY SIDEWALL SPRINKLER SPACING 8'-0 O.C. 16. ALL VALVES TO BE LABELED IN ACCORDANCE WITH NFPA-13D. 17. PIPE SHALL BE REQUIRED TO REMAIN ON A 2.25" CENTERLINE ON THE TOP OF THE BOTTOM TRUSS CORD ALLOWING FOR TENTING AND SHALL HAVE PRIORITY OVER OTHER TRADES. SCOPE OF WORK GLACIER FIRE PROTECTION WILL PROVIDE ONE WET PIPE AUTOMATIC SPRINKLER SYSTEM TO PROTECT THE NEW RESIDENCE. EXCLUSIONS PAINTING OR LABELING OF PIPE AND/OR EQUIPMENT ELECTRICAL WIRING OF ANY KIND INCLUDING BUT NOT LIMITED TO WATERFLOW SWITCH, ELECTRIC BELL, AND TAMPER SWITCHES CENTRAL STATION MONITORING EQUIPMENT, WIRING AND SERVICES CEILING AND WALL REMOVAUREPLACE TO FACILITATE THE INSTALLATION OF THE SPRINKLER SYSTEM. UNDERGROUND WORK OF ANY KIND DESIGN CRITERIA PER NFPA 13D (2016) RM -01 (RESIDENCE) THE DENSITY SHALL BE 13 GPM/SF OVER THE MOST REMOTE 2 SPRINKLERS WITHIN A COMPARTMENT. 16'-0 x 16'-0 MAX SPACING Sprinkler Legend Temperature L.L. 0 LL 0 h LL :(11 e— e— N .0 a) •0_ 0 Response Quick . U . 0 G(3 o e- Type Pendent 1 w Pendent K -Factor rn vi 4.4 5.8 Quantity M N e- Total = 40 Model Ch F3RES44 DRY co 3 w "' et (0 RA5231 co z cr cc Manufacturer a) m Reliable a) w15 1T)Ole Symbol WATER FLOW INFORMATION NORTH FIRE SPRINKLER RISER WATER GAUGE : ._. 1" DRAN Oy FLOW SV TCH -- DOMESTIC LINE . BY OTHERS GLACIER FIRE PROTECTION, LLC TO START WORK: HERE 1112'AMES 20008 BACKFLOW PREVENTOR PROVIDED AND INSTALLEfJ:'. BY OTHERS" 11/2" WATER BY OTHERS RY MAINTAIN 2"AyNULAR CLEARANCE AROLND PIPE 160TH; ription WATER FLOW INFORMATION HAS BEEN PROVIDED BY HIGHLINE WATER DISTRICT STATIC: 68.96 PSI RESIDUAL: 52.17 PSI FLOW: 1500 GPM DR.W1.NG INDEX FP 0.10 SITE PLAN AND NOTES FP 2.10 ` BASEMENT MAIN AND .UPPER FLOOR PLAN GLACIER FIRE PROTECTION LLC PO BOX 7980 BONNEY LAKE, WA 98391 P: (253)501-7558 www.glacierfireprotection.00m GLACIFP834MJ Ctl RTIF$CATE t 1RR Erin Clayton 750817-0 Level 3 Glacier Fire Protection, L. GLACIFP834MJ VICINITY AP DATE: 02107/'19. NTRACT FLOOR / AREA SITE PLAN AND NOTES SHEET NUMBER OUTDOOR LNG NORTH GLACIER FIRE LLC PO BOX 7980 BONNEY LAKE, WA 98391 P: (253) 501:7558 www.glacierfireprotection.com GLACIFP834MJ 3 -CAR GARAGE CONC /SLOPE 4" TO`OH 0f RRS BASEMENT LEVEL PLAN SCALE : 1/4" = 1'-0 MAIN LEVEL PLAN SCALE >1/4" =1'-0 Erin Clayton 7544-0817-C Level.3 Glacier Fire Protection, L. GLACIFP834MJ W co DRAWN BY: SFC' REVISIONS Na '; DESCRIPTION z DATE: : 02/07/19 CONTRACT #:40095 FLOOR / AREA SEMENTAND MAIN FLOOR PL/.1! SHEET NUMBER FP 2.1 0 2 of:3 Hydraulic Irs or nation Remote Area 1 OCCUPANCY CLASSIFICATION Residential DENSITY (gpmfft2) 0.05 for .900ft (Actual 184ft2) TOTAL HEADS FLOWING _ 2 112" K=FACTOR 4.9 TOTAL WATER REQUIRED 26.82 TOTAL PRESSURE REQUIRED 47.202 BASE of RISER (gpm) 26.82 BASE of RISER (psi) 47.202 SAFETY MARGIN (psi) +21.748` (31.5%) PIPE SHALL BE REQUIRED TO REMAIN ON A2.25" CENTERLINE ON THETOP OF THE BOTTOM TRUSS CORD ALLOWING FOR TENTING AND SHALL HAVE PRIORITY OVER OTTER TRADES, ADEQUATE INSULATION BY OTHERS. GLACIER FIRE PROTECTION LLC PO BOX 7980 BONNEY LAKE, WA 98391 P: (253).501-7558; YO giaeierficeprotec ion.com 'GLACIFP834MJ ♦ co;+:04.4 NO - BLOCK •� !e' ®.o������►FASTENER CPV G PIPE TJI JOIST SCALE :1/4"=1'.0 PIPE TENT INSULATION DETAIL #1 SCALE NT.S. 00 STANCES FOR TEMPERATURE RESIDENTIAL SPSPRINKLER BLOWN -IN INSULATION ABOVE BA INSULATION esvrrw-ur..ttin COLD SPACE SIDE OF OPEN OR RECESSED FIRE PLACE FRONT OF RECESSED FIREPLACE COAL -OR WOOD BURNING STOVE KITCHEN RANGE IALLOVEN' J w a.; MINIM HOT AIR FLUES UNINSULATED HEAT DUCTS UNINSULATED HOT WATER PIPES SIDE OF CEILING OR WALL MOUNTED HOT AIR DIFFUSERS FRONT OF WALL MOUNTED HOT AIR DIFFUSERS rn__ HOT WATER HEATER OR FURNACE` LIGHT FIXTURE OW -250W #'1011" HEX HEAD CAP SCREW COMPOSITE WOOD--_ i -JOIST VAPOR BARRR PER NEPA 13D TABLE 7.5.5s HANGER SPACING LEGEND ' NOMINAL PIPE SIZE (IN.) 3/4'e 1" '` 1 1!4" 1 1/2" 2"' 2 112" 3" 4" 6" 8" STEEL PIPE SCH 40, SCH 10, DF,EF N/A , 12-0 12-0 15-0 15-0 15-0 15-0 , 15-0 15-0 15-0 THREADED LIGHTALL N/A 12-0 12-0 12-012-0 ` 12-0 N/A' N/A N/A N/A COPPER 8-0 8-0 10-0 10.0 1241 12-0 12-0 ' 15.0 15-0 15.0 CPUC 5-6 6-0 6-6 7-0 8-0 -0 10-0 N/A N/A N/A PER NFPA 139.2.2.1(A) TJI SPACE CONTRACT#:40095 Erin Clayton 7544-0817-C Level 3 Glacier Fire Protection, L. OLACIFP834MJ FLOOR /AREA UPPER FLOOR PLAN 02/04/2019