HomeMy WebLinkAboutPP - 4650 S 160TH ST - RESIDENCE - PERMITS AND PLANS4650 S 160TH ST ASSOCIATED PERMITS 95-5-009 B94-0276 B94-0275 City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 FILE John W. Rants, Mayor July 29, 1994 Fire Department Review Control #B94-0275 Re: Vandenberg - 4650 South 160th Street, Lot B Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. City Ordinance #1626 requires a fire hydrant to be within 250' of the nearest point of the building in the route of vehicular travel. Your site plan indicates the nearest hyrant to be 370' away. Installation of a fire hydrant to meet the requirements of City Ordinance #1626 shall be required for this project. 2. In lieu of the hydrant requirement, you may install an automatic residential sprinkler system. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and/or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1646) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1646) City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 Page number 2 John W. Rants, Mayor 3. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 4. Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 10.601) Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 10.301(a)) Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. file ncd City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 Fire Department Review Control #B94-0276 (512) FILE John W. Rants, Mayor July 29, 1994 Re: Vandenberg - 4650 South 160th Street, Lot C Dear Sir: The attached set of building plans have been reviewed by The Fire Prevention Bureau and are acceptable with the following concerns: 1. City Ordinance #1626 requires a fire hydrant to be within 250' of the nearest point of the building in the route of vehicular travel. Your site plan indicates the nearest hydrant to be 370' away. Installation of a fire hydrant to meet the requirements of City Ordinance #1626, shall be required for this project. 2. In lieu of the hydrant requirement, you may install an automatic residential sprinkler system. All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers, Kemper or any other representative designated and/or recognized by The City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #1646) Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (UFC 10.503) (City Ordinance #1646) City of Tukwila FIRE DEPARTMENT 444 Andover Park East Tukwila, Washington 98188-7661 (206) 575-4404 Page number 2 John W. Rants, Mayor 3. All electrical work and equipment shall conform strictly to the standards of The National Electrical Code. (NFPA 70) 4. Require fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (UFC 10.601) Your street address must be conspicuously posted on the building and shall be plainly visible and legible from the street. Numbers shall contrast with their background. (UFC 10.301(a)) Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. Yours truly, The Tukwila Fire Prevention Bureau cc: T.F.D. file ncd Retain current inspection schedule Needs shift inspection Approved without correction notice Approved with correction notice issued fpr. lers: Fire Alarm: Hood & Duct: Halon: Monitor Pre -Fire: Permits: l Authoriz' d Signatu e FINALAPP.FRM T.F.D. Form P. 85 Headquarters Station: 444 Ando er Park East • Tukwila, Washington 08188 • Phone (2157$4404 • Soy (206) 5754439 CONTRACTOR: ROBINSON PLUMBING INC. 607 S.E. EVERETT MALL WAY, SUITE 26 EVERETT, WA 98208 STATE OF WASHINGTON SPRINKLER LICENSE #RO-BI-NP-*272C2 LEVEL 2 682-0895 355-6171 DESIGNER: REGINA L. ROBINSON - ELMSLIE STATE OF WASHINGTON CERTIFICATE OF COMPETANCY #537-64-7117 LEVEL 2 BUILDER: GREG VANDENBERG PROPERTY ADDRESS: 4650 S. 160TH ST., TULWILA PARCEL: 222304-9104 TOTAL NUMBER OF SPRINKLER HEADS: 17 FIRE SPRINKLER SYSTEM NOTES: * FIRE SPRINKLER SYSTEM DESIGN PER N.F.P.A. STANDARD 13D * SPRINKLER SYSTEM TO BE WATER PRESSURE TESTED & FLOW TESTED r * SPRINKLER PIPING AND FITTINGS TO BE C.P.V.C. "EXTINGUISH SURE" BY R & G SLOANE CO. EXPOSED PIPING AND FITTINGS SHALL BE C.P.V.C. "EXTINGUISH SURE" 'UNDER SMOOTH CEILING CONSTRUCTION AS PER U.L. LISTING * UNDERGROUND WATER SERVICE TO BE COMBINATION DOMESTIC AND FIRE SPRINKLER * INSTALLATION OF C.P.V.C. PIPE AND FITTINGS TO BE DONE BY MANUFACTUROR CERTIFIED INSTALLERS * FLOW SWITCH WIRED TO ALARM BELL @ EXTERIOR * THREE SPARE SPRINKLER HEADS TO BE PROVIDED ALONG WITH INSTRUCTIONS TO HOMEOWNER / TENANT * SPRINKLER HEADS TO BE CENTRAL "R1M" PENDANT RESIDENTIAL QUICK RESPONSE AS PER LISTING * LINES IN ATTIC TO BE PROTECTED FROM FREEZING WITH INSULATION OVER THE TOP OF THE PIPING (BY INSULATION CONTRACTOR) * DESIGN SPACING IS 16' X 16' * DESIGN AREA IS FOR 2 HEAD FLOW * MINIMUM FLOW REQUIREMENTS FOR HEADS ARE: (1) HEAD FLOW = 14 GPM @ 12.9 PSI (2) HEAD FLOW = 11 GPM @ 8.0 PSI JOB: VANDENBERG SPRINKLER ADDRESS: 4650 S. 160TH, TUKWILA DESIGNER: REGINA L. ROBINSON-ELMSLIE CALCULATIONS FOR 14 GPM FLOW (1 HEAD) IND. LOSS NET TOTAL A. WATER PRESSURE IN STREET 80.00 B. ARBITRARY SELECT PIPE SIZE: C. DEDUCT METER LOSS (1") 2.00 78.00 D. DEDUCT HEAD LOSS FOR ELEVATION SYSTEM CONTROL VALVE HEIGHT= 20.00 X 0.434 8.68 69.32 E. DEDUCT PRESSURE LOSS FROM CITY MAIN TO SPRINKLER (1-1/2" WATER SERVICE) ITEM QUANTITY EQUIV FT. TOTAL FT. PIPE: 210.00 1.00 210.00 VALVES:2.00 2.00 4.00 ELBOWS:4.00 3.00 12.00 TEES: 1.00 2.00 2.00 TOTAL: 228.00 . TOTAL EQUIVALENT FT X .01 PSI/FT = 2.28 67.04 F: DEDUCT PRESSURE LOSS FOR 1-1/2" PIPING • CONTROL VALVE TO FARTHEST SPRINKLER ITEM QUANTITY EQUIV FT. TOTAL FT. PIPE: 24.00 1.00 24.00 ELBOWS:2.00 7.00 14.00 R-TEES:1.00 1.00 1.00 B-TEES:0.00 5.00 0.00 DCHECK:1.00 196.00 196.00 VALVE: 0.00 1.00 0.00 TOTAL: 235.00 TOTAL EQUIVALENT FT X .0057 PSI/FT = 1.34 65.70 DEDUCT PRESSURE LOSS FOR 1" PIPING CONTROL VALVE TO FARTHEST SPRINKLER ITEM QUANTITY EQUIV FT. TOTAL FT. PIPE: 71.00 1.00 71.00 ELBOWS:9.00 7.00 63.00 R-TEES:8.00 1.00 8.00 B-TEES:1.00 5.00 5.00 TOTAL: 0.00 147.00 TOTAL EQUIVALENT FT X .0340 PSI /FT = 5.00 60.70/;;='`` REMAINING PRESSURE FOR SPRINKLER OPERATION 60 CALCULATIONS PER NFPA 13D A-4-4.3(1) Regina l . :<i+yen-trro�lie 57-64-7117 JOB: VANDENBERG SPRINKLER ADDRESS: 4650 S. 160TH, TUKWILA DESIGNER: REGINA L. ROBINSON-ELMSLIE CALCULATIONS FOR 22 GPM FLOW (2 HEADS) IND. LOSS NET TOTAL A. WATER PRESSURE IN STREET B. ARBITRARY SELECT PIPE SIZE: C. DEDUCT METER LOSS (1") D. DEDUCT HEAD LOSS FOR ELEVATION SYSTEM CONTROL VALVE HEIGHT= 20.00 X 0.434 E. DEDUCT PRESSURE LOSS FROM CITY MAIN TO SPRINKLER (1-1/2" WATER SERVICE) ITEM QUANTITY EQUIV FT. TOTAL FT. PIPE: 210.00 VALVES:2.00 ELBOWS:4.00 TEES: 1.00 TOTAL: 1.00 210.00 2.00 4.00 3.00 12.00 2.00 2.00 228.00 80.00 3.00 77.00 8.68 68.32 TOTAL EQUIVALENT FT X .015 PSI/FT = 3.42 64.90 F: DEDUCT PRESSURE LOSS FOR 1-1/2" PIPING CONTROL VALVE TO FARTHEST SPRINKLER ITEM QUANTITY EQUIV FT. TOTAL FT. PIPE: 24.00 ELBOWS:2.00 R-TEES:1.00 B-TEES:0.00 DCHECK:1.00 VALVE: 0.00 TOTAL: 1.00 24.00 7.00 14.00 1.00 1.00 5.00 0.00 196.00 196.00 1.00 0.00 235.00 TOTAL EQUIVALENT FT X .0131 PSI/FT = 3.08 61.82 DEDUCT PRESSURE LOSS FOR 1" PIPING CONTROL VALVE TO FARTHEST SPRINKLER ITEM QUANTITY EQUIV FT. TOTAL FT. PIPE: 71.00 ELBOWS:9.00 R-TEES:8.00 B-TEES:1.00 TOTAL: 1.00 71.00 7.00 63.00 1.00 8.00 5.00 5.00 147.00 TOTAL EQUIVALENT FT X .0783 PSI/FT = 11.51 REMAINING PRESSURE FOR SPRINKLER OPERATION CALCULATIONS PER NFPA 13D A-4-4.3(1) tie / r A J PATIO NGO FSD M-# T 4ITCtEL L N/ING-7 ThV VA t-ve t Dc-%, /4.) LAND/ 5C./6, L % 1/4" 1 ACCEPTED WITHOUT COMMENTS. AS NOTED IN RED PER THE ATTACHED LETTER The drawings affixed hereto have been reviewed and accepted by the City of Tukwila Fire Dept Additions, deletions or revisions to these drawings after this date will void thi3 acceptance and will require a resubmittal of revised drawings. Final acceptance is subject to field - inspection by a representative of this department DATE.IA r_BY,_ CITY OF TUKWILA 5/5-4407 Q - JT/.0 L G? Z P�JLig AJT (scc --.%t -s "4" ) - Jt.S/o"/ - c/P c) e "Dau/'/ V' 7 ,Gi t. P',C i NO/Z,ZO.✓%At. P,AJE .41V0,24u4./G CALa11 ,4 /O/.% .JO4.)k. CoN fy %,v e '= - TUKWILA FIRE OEPM fiVIENT Please call: 575-4407 and give this job No. %S rfo ° IF and exact address for shut- down or restoration approval. lrCC�?l/� �6e�ZL� \! Ps 5e7-1 p6,-74 N IsA Fr7. F' ° -Iasi st44 t rz. eerbult2b 9 - 02-7/0 i obinson Plumbing inc_ 03 !. 11 `7 443 0et 43 h N "1 g 1/2b X ? a Job no 3-0/o3 D.1. / 212,9/4$34 D..*n 11 see F . 0,...N. Ff/ 11, 1 / "DA✓ 84 sill J PER FL OO;= SCA t 4 1 0' "/0 JC4[6 N=,r1- i3 Fr7 v n?L h -2_--2-(A) FrtT F W / 11 Robinson h b Al aO Q V)Q W _ � W� � 0 3 tv Q A II r 2 J A* p 2.0 /03 Da" i z /3//0/4':< D.M. ey zAzi Sn..i N. SPP