Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 4335 S 160TH ST - LANDFAIR - PERMITS AND PLANS
4335 S 160TH ST ASSOCIATED PERMITS 14-5-208 D14-0238 PW13-042 EgFERN Sc' FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION CITY OF TUIKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: King Co. Assessor's Tax No.: Site Address: 47 S 160th ST Suite Number: Floor: Tenant Name: New Tenant? ❑ - Yes ❑ - No Property Owner's Name: Sound Built Homes Mailing Address: 12815 Canyon Rd E Puyallup,WA 98373 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Mike Hutchinson Day Telephone: 2g 3 - 2-5 2 7q zZ Company Name: Evergreen Fire Protection Mailing Address: PO BOX 998 Puyallup 98371 City State Zip E-mail Address: Evergreenfirepro(&msn.com Fax Number: 253-252-7943 Valuation of Project (contractor's bid price): $ 4599.00 Scope of Work (please provide detailed information): new NFPA 13D fire sprinkler system PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is supject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a perlod of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause" remonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Mike Hutchinson Plan Permit App.doc Day Telephone: Date: 9/10/2014 253-381-4456 5/14/10 TFD FP Form 8 CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION 1-\-4V` King Co. Assessor's Tax No.: 433-7 S 160th st Site Address: Suite Number: Floor: Tenant Name: New Tenant? ® - Yes ❑ - No Property Owner's Name: Sound Built Homes Mailing Address: 12815 Canyon rd. E Puyallup WA 98373 CONTACT PERSON -if there are questions about the submittal. Mike Hutchinson Name: City State Zip 253 252 7942 Day Telephone: Evergreen Fire Protection Company Name: PO Box 998 Puyallup WA Mailing Address: evergreenfirepro@msn.com City State Zip E-mail Address: Fax Number: Total number of new/relocated devices or sprinkler heads: 32 Valuation of Project (contractor's bid price): $ 4599.00 Scope of Work (please provide detailed information): New 13 D fire system PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHED AGENT: Signature: Print Name: Plan Permit App.doc Date: Day Telephone: 1/2/13 TFD FP Form 8 INSPECTION RECORD Retain a copy with pmit INSPECTION NUMBER p©s7 . - bca3(0 ��-s- at)$ PERMIT NUMBERS CITY OF TUKVVILA FIRE DEPARTMENT 206-575-4407 Project:,Type L, .,°-C-A-ka Y," I of Inspection: SP . ,�.� "';71U b4-1._ Address: ('s3 S Suite #: S) 60 -- Contact Person: Special Instructions: Occupancy Type: Phone No.: )4Approved per applicable codes. Corrections required prior to approval. COMMENTS: Co r r —i1 -e AbZN vt0 33 _ S 1661‘1" - Needs btom- Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: ( 3-a- Date: /4/Vic"--- Hrs.: I $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F D. Form F.P. 113 INSPECTION NUMBER INSPECTION RE ORD Retain a copy wit per e e� -v01 - PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: _ ca -k rz_ 4-07-- I Type of Inspection: Address:S /G o÷"---- Suite #: �L�22,,� Contact Person: Special Instruions: Pre -Fire: Phone No.: p4Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1. !0 e. p -e -e..6 ; D 4J r•4--. Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Date: (3ty( Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F,.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy w,jtlLpermit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: An_/�� � Z til g_ Type of In� ' kJ Address:,�,� 1 X00 Contact Pers n: Suite #: %� S • Special Instructions: «335 Phone No.: 'Approved per applicable codes. Corrections required prior to approval. COMMENTS: Q. -r - 1 Sikuks Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: -,-/i.C: 3,/ _ Date: 3/ Z "7• Hrs.: / n $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 ya31.)y.go, yae3 5,4,e(71s T.F.D. Form F.P. 113 y2 37- ey, 5h',,e% DATE: 9/10/2014 C:\program files\HRS Systems\hhouse34\2681.rdf EVERGREEN FIRE PROTECTION, INC. 10509 64th AVENUE E PUYALLUP,WA 98373 RESIDENTIAL SPRINKLER SYSTEM HYDRAULICS CALCULATION REPORT FOR Landfair lot 5 Tukwila, WA "337' S 160th st Date: 9/10/2014 File No: Data File Name: 2681.rdf SPRINKLER SPACING Page 1 256.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 16.0 ft. Min. Dist. Bet. Spklrs: 8.0 Max. Dist. Spklr. to Wall: 8.0 ft. SPRINKLER SPECIFICATIONS Mfr: 1 Reliable Descr: RA0612 RFC43 Fi Conc. Pend. (16x16) K=4.30 Calculated K Factor for Arm -Overs & Drops: 1.0 ft. x 1.101 in. Drop: K=4.26 (Incl. 1 Tee) 0.0 ft. x 1.101 in. Arm -Over: K=4.25 (Incl. 1 Tee & 1 Ell) PIPE SPECIFICATIONS Type: CPVC S-40 HWC: 150 WATER SUPPLY Source: Public Test Date: By: Static: 60.0 psi Resid: 0.0 psi Flow: 0.0 gpm Public Main Size: 0 in Domestic Demand: 0.0 gpm at node number 0 SPRINKLER DEMAND No.Spklrs. Min Spklr. Press. Node Total Avail. Req'd Flowing Flow (psi) No. Flow Press. Press. 1 13.0 9.3 1 13.0 60.0 32.2 2 13.0 9.3 1 26.2 60.0 42.4 REVIEWING AUTHORITY City of Tukwila DATE:.9/10/2014 C:\program files\HRS Systems\hhouse34\2681.rdf Page 2 P R E S S U R E ( P S I 60.0 54.0 48.0 42.0 36.0 WATER SUPPLY CURVE A cB 30.0 24.0 18.0 12.0 6.0 C CD 0.0 I I I 1 1 1 1 1 1 04 8 12 16 20 24 28 32 36 40 FLOW (GPM) Static = 60.0 psi (fixed pressure) (1 sprinkler flowing) (2 sprinklers flowing) A = Available Water Supply 60.0 psi @ 13.0 gpm B = Required Water Supply 32.2 psi @ 13.0 gpm C = Available Water Supply 60.0 psi @ 26.2 gpm D = Required Water Supply 42.4 psi @ 26.2 gpm DATE: 9/10/2014 C:\program files\HRS Systems\hhouse34\2681.rdf Page 3 RESULTS OF ANALYSIS NFPA NODE & PIPE DATA 1 Sprinkler Flowing Node Tag Elevation Node Type Pressure Discharge Notes (FT) (PSI) (GPM) 1 20.0 K= 4.26 9.3 13.0 2 20.0 9.6 3 20.0 11.7 4 10.0 16.5 5 0.0 21.3 6 0.0 21.6 7 0.0 26.6 8 0.0 27.1 9 0.0 SOURCE 32.2 Pipe Tag K-fac AF AF to L C (Pt) Frm Node El (ft) PT (q) node/ Nom ID Fit F (Pe) Notes To Node El (ft) PT TF(Q) disch Act ID T FL/FT (Pf) Pipe: 1 4.26 10.00 150 0.3 2 20.0 9.6 13.0 Disch 1.000 R: 1 1.00 0.0 1 20.0 9.3 13.0 1.101 11.00 0.031 0.3 Pipe: 2 0.00 2B:10 44.00 150 2.1 3 20.0 11.7 13.0 1 1.000 2L:10 24.00 0.0 2 20.0 9.6 13.0 1.101 4R: 4 68.00 0.031 2.1 Pipe: 3 0.00 10.00 150 4.8 4 10.0 16.5 13.0 2 1.000 L: 5 5.00 4.3 3 20.0 11.7 13.0 1.101 15.00 0.031 0.5 Pipe: 4 0.00 4.00 150 4.8 5 0.0 21.3 13.0 3 1.000 2L:10 10.00 4.3 4 10.0 16.5 13.0 1.101 14.00 0.031 0.4 Pipe: 5 0.00 5.00 150 0.3 6 0.0 21.6 13.0 4 1.000 4R: 4 4.00 0.0 5 0.0 21.3 13.0 1.101 9.00 0.031 0.3 Pipe: 6 0.00 1.00 150 5.0 7 0.0 26.6 13.0 5 1.000 0.00 0.0 6 0.0 21.6 13.0 1.101 1.00 0.031 5.0 Fixed Pressure Loss Device: 5.00 psi Pipe: 7 0.00 79.00 150 0.5 8 0.0 27.1 13.0 6 1.500 4L:28 28.00 0.0 7 0.0 26.6 13.0 1.598 107.00 0.005 0.5 Pipe: 8 SOURCE 1.00 150 5.0 9 0.0 32.2 13.0 7 1.000 0.00 0.0 8 0.0 27.1 13.0 1.101 1.00 0.030 5.0 Fixed Pressure Loss Device: 5.00 psi DATE: 9/10/2014 C:\program files\HRS Systems\hhouse34\2681.rdf Page 4 RESULTS OF ANALYSIS NFPA NODE & PIPE DATA 2 Sprinklers Flowing Node Tag Elevation Node Type Pressure Discharge Notes (FT) (PSI) (GPM) 1 20.0 K= 4.26 9.3 13.0 2 20.0 K= 4.26 9.6 13.2 3 20.0 17.3 4 10.0 23.3 5 0.0 29.2 6 0.0 30.2 7 0.0 35.3 8 0.0 37.3 9 0.0 SOURCE 42.4 Pipe Tag K-fac AF AF to L C (Pt) Frm Node El (ft) PT (q) node/ Nom ID Fit F (Pe) Notes To Node El (ft) PT TF(Q) disch Act ID T FL/FT (Pf) Pipe: 1 4.26 10.00 150 0.3 2 20.0 9.6 13.0 Disch 1.000 R: 1 1.00 0.0 1 20.0 9.3 13.0 1.101 11.00 0.031 0.3 Pipe: 2 4.26 13.2 Disch 2B:10 44.00 150 7.6 3 20.0 17.3 13.0 1 1.000 2L:10 24.00 0.0 2 20.0 9.6 26.2 1.101 4R: 4 68.00 0.112 7.6 Pipe: 3 0.00 10.00 150 6.0 4 10.0 23.3 26.2 2 1.000 L: 5 5.00 -4.3 3 20.0 17.3 26.2 1.101 15.00 0.112 10.4 Pipe: 4 0.00 4.00 150 5.9 5 0.0 29.2 26.2 3 1.000 2L:10 10.00 -4.3 4 10.0 23.3 26.2 1.101 14.00 0.112 10.2 Pipe: 5 0.00 5.00 150 1.0 6 0.0 30.2 26.2 4 1.000 4R: 4 4.00 0.0 5 0.0 29.2 26.2 1.101 9.00 0.112 1.0 Pipe: 6 0.00 1.00 150 5.1 7 0.0 35.3 26.2 5 1.000 0.00 0.0 6 0.0 30.2 26.2 1.101 1.00 0.112 5.1 Fixed Pressure Loss Device: 5.0 psi Pipe: 7 0.00 79.00 150 2.0 8 0.0 37.3 26.2 6 1.500 4L:28 28.00 0.0 7 0.0 35.3 26.2 1.598 107.00 0.018 2.0 Pipe: 8 SOURCE 1.00 150 5.1 9 0.0 42.4 26.2 7 1.000 0.00 0.0 8 0.0 37.3 26.2 1.101 1.00 0.112 5.1 Fixed Pressure Loss Device: 5.0 psi DATE: 9/10/2014 C:\program files\HRS Systems\hhouse34\2681.rdf Legend: PT - Total Pressure at Node F1 - Flow rate (gpm) L - Pipe Length F - Fitting Length T - Total Length of Pipe C - Hazen -Williams Coefficient FL/FT - Friction Loss per Foot Pt - Total Pressure Loss Pe - Elevation Pressure Loss Pf - Friction Pressure Loss Page 5 Fitting Code Letters: E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, S=SwgChk, G=GatVly, X= X, Y= The maximum velocity of water flow occurs in pipe 2 at 4.38 ft/s with 1 sprinkler flowing. The maximum velocity of water flow occurs in pipe 4 at 8.84 ft/s with 2 sprinklers flowing. PIPE FITTINGS TABLE Pipe Table Name: standard.npt PAGE: C Diameter (in) 1.101 1.598 MATERIAL: CPVC S-40 HWC: 150 Equivalent Fitting Lengths E L B R C 45 Ell 90 Ell TeeBch TeeRun Couplg 1.00 5.00 5.00 1.00 1.00 2.00 7.00 8.00 1.00 1.00 in Feet S G X Y Z SwgChk GatVly X Y Z 8.00 2.00 0.00 0.00 0.00 14.00 3.00 0.00 0.00 0.00 A negative value for flow rate indicates the direction of flow is from the second pipe nc A Fixed Pressure Loss Device calcualtes as a positive friction loss A Fire Pump calculates as a negative friction loss Sprinkler system has been hydraulically calculated with the HASS HOUSE 3.4 computer program (License No. R609099990) to provide an average imbalance of 0.020 gpm at each node and a maximum imbalance of 0.18 gpm with one sprinkler flowing, and 0.010 gpm at each node and maximum imbalance of 0.09 gpm with 2 sprinklers flowing in accordance with NFPA 13 and 13D or 13R. The minimum source pressure is 20.0 psi with a minimum required pressure of 42.4 psi and a 7 minute flow of 184 gal. and a 10 minute flow of 262.3 gallons. The minimum pressure at any node is 9.3 psi at node 1. Under full flow conditions the minimum source pressure is 20.0 psi with a minimum of 60.0 psi and a 7 minute flow of 245 gal. and a 10 minute flow of 350.0 gallons. The minimum pressure at any node is 16.6 psi at node 1. HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 GARAGE FAMILY ROOM RINKLER RISER TO UPPER FLOOR KITCHEN wain BTLR F NTR / 1�— DININ ROOM 9 —0 CEILING COFFERED { 1`' '`PWDR { VAI\ FLOO PLA\ ALL PIPE TO BE 1"CPVC UNLESS OTHERWISE NOTED 6" 120v Eelk to be located on the exterior approach to home 1/4" = 1'-0' WATER FLOW INDICATOR • s STA11C WATER PRESSURE 60 psi TO St STEM PRESSURE GAUGE NTS DRAIN VALVE r I !I , it s 1 dKWILA FIRE DEPARTMENT Pim call 206-575-4407 and sive this Fire Permit No. Lod exact address for shut- down or restoration approval. �y..,ii'r%%% TEST HEADS (2) VIMWMMWOMMN WALK—IN PLAYROOM MASTER BEDROOM 4f6YAIP259.01117.0404 PE OP 70503leorafr 0 BEDROOM 2 OPEN TO BELOW ,I BEDROOM 4 v DRAIN PIPED TO EXTERIOR 1AMES 2000B BACKFLOW PREVENTER To domestic piping 15 i[> SP1NKLER 80 �ISE� 1" WATER METER r 1 75 1 1 rs 1 e REDROOM 3 r , 9 %/ 47. r L 11 L_ __ JDPER FLOOR • ACCEPTED ❑ Without Comments Er As Noted in Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire rre' ention Bureau for conformance with current Clty arldards Acceptance is subject to errors and omissions which do not authorize v.olations of adopted tndards and ordinances The responslbhity for the .JGquacy of design rests totally with the designer 4ddltlons, deletions or revisions to these drawings after this aate will void this acceptance and will require a resubmittal of revised drawings for subsequent approval Final acceptance Is subject to Reid test and inspection by The Tukwila Fire Prevention Bureau Date q-.4.73-IY By Ale-. sIf Shskcll 'exitr;ov we4L1,p.Droo+ (01-r1 140.41- ¶144 D IIIc. o,to+ 5 �(o►� Ne Flow (LJk4-) 4e3's rf y. yob rid, d 6 5 3 A warning sign with minimum'/. inch letters shall be affixed adjacent to the main shutoff valve and shall state the following WARNING The water system for this home supplies fire sprinklers that require certain flows and pressures to fight a fire Devices that restrict the flow or decrease the pressure or automatically shut off the water to the fire sprinkler system such as water softeners filtration systems and automatic shut off valves shall not be added to this system without a review of the fire sprinkler system by a fire protection specialist Do not remove this sign LA\ PIPE /0 \1 INSULATION 1 k 1 I' 1 1 1 A T 1 751 M. 1 Tr 1. 1 , ,-• f\ r- T A 1 1 1/4' = 1'-0" R i L 4 1 Stamp CSRT1FICATEEOFOCOMP STATE aus PROTECTION SPRINKLER SYSTEMS I Michael D Hutchinson 1166 -0599 -BG Level 2 Evergreen Fire Protection Inc EVERGFP967LZ n SIMIat.r. General Notes 1 OWNER TO PROVIDE ADEQUATE HEAT (40T MIN) TO PREVENT SPRINKLER PIPES FROM FREEZING 2 OWNER TO PROVIDE HARD WIRED HOME SMOKE DETECTION SYSTEM 3 CPVC PIPE SHALL HAVE HANGERS 6 —0" c\c AND NOT MORE THAN 6" FROM ANY SPRINKLER HEAD 4 ALL ATTIC PIPING TO BE TENTED WITH BATT INSULATION TO PREVENT FREEZING 5 ALL PIPING TO BE 1" CP VC UN 0 6 A 6" BELL TO BE LOCATED ON THE EXTERIOR APPROACH TO HOME IF REQUIRES BY THE LOCAL A H J 7 IF A OUTLET FOR A FUEL FIRED APPLIANCE IS PIPED ON AN EXTERIOR COVERED DECK A INTERMEDIATE TEMP DRY SPRINKLER WILL BE INSTALLED SYM ' 0 Sprinkler Symbol Legend SPRINKLER ORIFICE SIZE TYPE & FINISH RELIABLE RFC 43 16 x16 2 head flow requirement 26 GPM CO 9 6 psi RELIABLE F1 RES 49 16 x16 FLOW REQUIREMENT 26 GPM ® 9 6 psi RELIABLE F1 RES 44 SIDEWALL 16 X 20 VICTAULIC DRY UPRIGHT Reliable F 3 QR DRY Sidewoll TOTAL QUAN 29 3 32 TEMP 155 155 155 200 155 K FACTOR 49 43 43 56 56 DATE 9/8/2014 EVEGEEN FRE PROTECTION INC Po BOX 998 Puyallup, WA 98371 EVERGFP967LZ Phone (253) 252-7942 REV I DRAWN MH I SHEET 1 OFI Sheet Title \FDA 133 FIRE LA\ 2681 Lancfair lot 5 S 16Cthst 4 TUKWIIC,WA 98188 Job Title 1