HomeMy WebLinkAboutPP - 4339 S 160TH ST - LANDFAIR - PERMITS AND PLANS4339 S 160TH ST ASSOCIATED PERMITS 14-S-209 14-5-207 D14-0142 IFEMEN SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATitON Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: 4319 S 160th ST King Co. Assessor's Tax No.:: Suite Number: Floor: Tenant Name: New Tenant? ❑ - Yes ❑ - No Property Owner's Name: Sound Built Homes Mailing Address: 12815 Canyon Rd E Puyallup,WA 98373 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Mike Hutchinson Company Name: Evergreen Fire Protection Day Telephone:153 - 2 5 2 - 761 f -1 Z Mailing Address: PO BOX 998 Puyallup 98371 City State Zip E-mail Address: Evergreenfirepro@msn.com Fax Number: 253-252-7943 Valuation of Project (contractor's bid price): $ 4161.00 Scope of Work (please provide detailed information): new NFPA 13D fire sprinkler system PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issupnce, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 9/10/2014 Print Name: Mike Hutchinson Day Telephone: 253-381-4456 Plan Permit App.doc 5/14/10 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 4339 S 160th st Site Address: Suite Number: Floor: Tenant Name: New Tenant? ®- Yes ❑ - No Property Owner's Name: Sound Built Homes Mailing Address: 12815 Canyon rd. E Puyallup WA 98373 City State Zip CONTACT PERSON -if there are questions about the submittal. Mike Hutchinson Name: 253 252 7942 Day Telephone: Evergreen Fire Protection Company Name: PO Box 998 Puyallup WA Mailing Address: evergreenfirepro@msn.com City State Zip E-mail Address: Fax Number: Total number of new/relocated devices or sprinkler heads: 24 Valuation of Project (contractor's bid price): $ 4161.00 Scope of Work (please provide detailed information): New 13 D fire system PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 OR AUTIZED AGENT: Signature: Date: Print Name: ` ` {, } a � t ' Day Telephone: Plan Permit App.doc 1/2/13 TFD FP Form 8 3 INSPECTION NUMBER INSPECTION RECORD Retain a copy with per 0,0b) � y - 5- ac% PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Aj S -F e____ Sprinklers: Fire Alarm: Typ of I spection Address: s31 Suite #: s /1,0 Conta Person: Special Instructions: SP Phone No.: IR Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: &' -1''e-71- — o14 P/ 00-4 a 5 Crwt ittP v.,•‘ A) SP iv, L —op._ Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: ( Date: 3/7/4,1---- Hrs.: I $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 I INSPECTION NUMBER INSPECTION RECORD Retain a copy withrmit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 47Type 4M7/€ Sprinklers: of Inspection':/ Address: v,;2jContact Suite #: 37" 5 X60 sa Person: Special Instructions: Occupancy Type: , Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: PA'frt‘ b N S' _ //LeuP� 7.a.c� �A �,+f� inti 5 F,�-, Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: , Inspector: l7�� l7353 Date:/Z/yO Hrs.: /6 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F..D. Form F.P. 113 DATE: 9/10/2014 C:\program files\HRS Systems\hhouse34\2603aa.rdf t+ EVERGREEN FIRE PROTECTION, INC. 10509 64th AVENUE E PUYALLUP,WA 98373 RESIDENTIAL SPRINKLER SYSTEM HYDRAULICS CALCULATION REPORT FOR Landfair lot 4 Tukwila,WA 4339 S 160th st Date: 9/10/2014 File No: Data File Name: 2603aa.rdf SPRINKLER SPACING Page 1 256.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 16.0 ft. Min. Dist. Bet. Spklrs: 8.0 Max. Dist. Spklr. to Wall: 8.0 ft. SPRINKLER SPECIFICATIONS Mfr: 1 Reliable Descr: RA0612 RFC43 F1 Conc. Pend. (16x16) K=4.30 Calculated K Factor for Arm -Overs & Drops: 1.0 ft. x 1.101 in. Drop: K=4.26 (Incl. 1 Tee) 0.0 ft. x 1.101 in. Arm -Over: K=4.25 (Incl. 1 Tee & 1 Ell) PIPE SPECIFICATIONS Type: CPVC S-40 HWC: 150 WATER SUPPLY Source: Public Test Date: By: Static: 60.0 psi Resid: 0.0 psi Flow: 0.0 gpm Public Main Size: 0 in Domestic Demand: 0.0 gpm at node number 0 SPRINKLER DEMAND No.S0lrs. Min Spklr. Press. Node Total Avail. Req'd Flowing Flow (psi) No. Flow Press. Press. 1 13.0 9.3 1 13.0 60.0 33.4 2 13.0 9.3 1 26.1 60.0 46.8 REVIEWING AUTHORITY City of Tukwila 1 IAicheel D. Hubddnson 110 Lave! 2 Ever resin Fee Inc. 712 DATE: 9/10/2014 C:\program files\HRS Systems\hhouse34\2603aa.rdf Page 2 P R E S S U R E ( S 1 WATER SUPPLY CURVE 60.0 CA �C 54.0 48.0 42.0 36.0 30.0 24.0 18.0 12.0 6.0 CB CD 0.0 1 1 1 1 1 1 I 1 1 I 04 8 12 16 20 24 28 32 36 40 FLOW (GPM) Static = 60.0 psi (fixed pressure) (1 sprinkler flowing) (2 sprinklers flowing) A = Available Water Supply 60.0 psi @ 13.0 gpm B = Required Water Supply 33.4 psi @ 13.0 gpm C = Available. Water Supply 60.0 psi @ 26.1 gpm D = Required Water Supply 46.8 psi @ 26.1 gpm DATE: 9/10/2014 C:\program files\HRS Systems\hhouse34\2603aa.rdf Page 3 w RESULTS OF ANALYSIS NFPA NODE & PIPE DATA 1 Sprinkler Flowing Node Tag Elevation Node Type Pressure Discharge Notes (FT) (PSI) (GPM) 1 20.0 K= 4.26 9.3 2 20.0 9.7 3 20.0 9.7 4 20.0 11.7 5 10.0 16.5 6 0.0 22.6 7 0.0 22.9 8 0.0 27.9 9 0.0 28.4 10 0.0 SOURCE 33.4 13.0 Pipe Tag K-fac AF AF to L C (Pt) Frm Node El (ft) PT (q) node/ Nom ID Fit F (Pe) Notes To Node El (ft) PT TF(Q) disch Act ID T FL/FT (Pf) Pipe: 1 4.26 7.00 150 0.4 3 20.0 9.7 13.0 Disch 1.000 B: 5 5.00 0.0 1 20.0 9.3 13.0 1.101 12.00 0.031 0.4 Pipe: 2 0.00 3.00 150 0.0 3 20.0 9.7 0.0 1.000 B: 5 5.00 0.0 2 20.0 9.7 0.0 1.101 8.00 0.000 0.0 Pipe: 3 0.00 B: 5 51.00 150 2.1 4 20.0 11.7 13.0 1 1.000 L: 5 16.00 0.0 3 20.0 9.7 13.0 1.101 6R: 6 67.00 0.031 2.1 Pipe: 4 0.00 10.00 150 4.8 5 10.0 16.5 13.0 3 1.000 L: 5 5.00 4.3 4 20.0 11.7 13.0 1.101 15.00 0.031 0.5 Pipe: 5 0.00 3B:15 34.00 150 6.0 6 0.0 22.6 13.0 4 1.000 L: 5 22.00 4.3 5 10.0 16.5 13.0 1.101 2R: 2 56.00 0.031 1.7 Pipe: 6 0.00 5.00 150 0.3 7 0.0 22.9 13.0 5 1.000 4R: 4 4.00 0.0 6 0.0 22.6 13.0 1.101 9.00 0.031 0.3 Pipe: 7 0.00 1.00 150 5.0 8 0.0 27.9 13.0 6 1.000 0.00 0.0 7 0.0 22.9 13.0 1.101 1.00 0.031 5.0 Fixed Pressure Loss Device: 5.00 psi Pipe: 8 0.00 79.00 150 0.5 9 0.0 28.4 13.0 7 1.500 4L:28 28.00 0.0 8 0.0 27.9 13.0 1.598 107.00 0.005 0.5 Pipe: 9 SOURCE 1.00 150 5.0 10 0.0 33.4 13.0 8 1.000 0.00 0.0 9 0.0 28.4 13.0 1.101 1.00 0.031 5.0 DATE: 9/10/2014 C:\program files\HRS Systems\hhouse34\2603aa.rdf Page 4 Fixed Pressure Loss Device: 5.00 psi RESULTS OF ANALYSIS NFPA NODE & PIPE DATA 2 Sprinklers Flowing Node Tag Elevation Node Type Pressure Discharge Notes (FT) (PSI) (GPM) 1 20.0 K= 4.26 9.3 13.0 2 20.0 K= 4.26 9.4 13.1 3 20.0 9.7 4 20.0 17.1 5 10.0 23.1 6 0.0 33.7 7 0.0 34.7 8 0.0 39.8 9 0.0 41.7 10 0.0 SOURCE 46.8 Pipe Tag K-fac AF AF to L C (Pt) Frm Node El (ft) PT (q) node/ Nom ID Fit F (Pe) Notes To Node El (ft) PT TF(Q) disch Act ID T FL/FT (Pf) Pipe: 1 4.26 7.00 150 0.4 3 20.0 9.7 13.0 Disch 1.000 B: 5 5.00 0.0 1 20.0 9.3 13.0 1.101 12.00 0.031 0.4 Pipe: 2 4.26 3.00 150 0.2 3 20.0 9.7 13.1 Disch 1.000 B: 5 5.00 0.0 2 20.0 9.4 13.1 1.101 8.00 0.031 0.2 Pipe: 3 0.00 13.1 2 B: 5 51.00 150 7.4 4 20.0 17.1 13.0 1 1.000 L: 5 16.00 0.0 3 20.0 9.7 26.1 1.101 6R: 6 67.00 0.111 7.4 Pipe: 4 0.00 10.00 150 6.0 5 10.0 23.1 26.1 3 1.000 L: 5 5.00 -4.3 4 20.0 17.1 26.1 1.101 15.00 0.111 10.3 Pipe: 5 0.00 3B:15 34.00 150 10.6 6 0.0 33.7 26.1 4 1.000 L: 5 22.00 -4.3 5 10.0 23.1 26.1 1.101 2R: 2 56.00 0.111 14.9 Pipe: 6 0.00 5.00 150 1.0 7 0.0 34.7 26.1 5 1.000 4R: 4 4.00 0.0 6 0.0 33.7 26.1 1.101 9.00 0.111 1.0 Pipe: 7 0.00 1.00 150 5.1 8 0.0 39.8 26.1 6 1.000 0.00 0.0 7 0.0 34.7 26.1 1.101 1.00 0.111 5.1 Fixed Pressure Loss Device: 5.0 psi Pipe: 8 0.00 79.00 150 1.9 9 0.0 41.7 26.1 7 1.500 4L:28 28.00 0.0 8 0.0 39.8 26.1 1.598 107.00 0.018 1.9 Pipe: 9 SOURCE 1.00 150 5.1 DATE: 9/10/2014 C:\program files\HRS Systems\hhouse34\2603aa.rdf 10 0.0 46.8 26.1 8 1.000 9 0.0 41.7 26.0 1.101 Fixed Pressure Loss Device: Legend: PT - Total Pressure at Node F1 - Flow rate (gpm) L - Pipe Length F - Fitting Length T - Total Length of Pipe 0.00 1.00 0.111 5.0 psi C - Hazen -Williams Coefficient FL/FT - Friction Loss per Foot Pt - Total Pressure Loss Pe - Elevation Pressure Loss Pf - Friction Pressure Loss Fitting Code Letters: E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, The maximum velocity of water flow occurs in pipe at 4.38 ft/s with 1 sprinkler flowing. The maximum velocity of water flow occurs in pipe at 8.79 ft/s with 2 sprinklers flowing. PIPE FITTINGS TABLE Pipe Table Name: standard.npt PAGE: C MATERIAL: CPVC S-40 HWC: 150 Diameter Equivalent Fitting Lengths (in) E L B R C 45 Ell 90 Ell TeeBch TeeRun Couplg 1.101 1.00 5.00 5.00 1.00 1.00 1.598 2.00 7.00 8.00 1.00 1.00 Page 5 0.0 5.1 S=SwgChk, G=GatV1v, 6 9 in Feet S G X Y SwgChk GatVly X Y 8.00 2.00 0.00 0.00 14.00 3.00 0.00 0.00 X= X, Y= z z 0.00 0.00 A negative value for flow rate indicates the direction of flow is from the second pipe nc A Fixed Pressure Loss Device calcualtes as a positive friction loss A Fire Pump calculates as a negative friction loss Sprinkler system has been hydraulically calculated with the HASS HOUSE 3.4 computer program (License No. R609099990) to provide an average imbalance of 0.010 gpm at each node and a maximum imbalance of 0.09 gpm with one sprinkler flowing, and 0.015 gpm at each node and maximum imbalance of 0.15 gpm with 2 sprinklers flowing in accordance with NFPA 13 and 13D or 13R. The minimum source pressure is 20.0 psi with a minimum required pressure of 46.8 psi and a 7 minute flow of 183 gal. and a 10 minute flow of 260.8 gallons. The minimum pressure at any node is 9.3 psi at node 1. HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 1 COV'D PATIO ACCEPTED Thebe plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City st ndards Acceptance is subject to errors and of which do not authorize violations of adopted standards and ordinances The responsibility for the dequacy of design rests totally with the designer oibons, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval TUKWI A FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. and exact address for shut- down hutdown or rem approval t Final acceptance Is subject to field test and Inspection by The Tukwila Fire Prevention Bureau Date ! s°Zi-1‘i By ,4i», i/ 1 3ED00M 2 10-5 X 10-7 UP FROM MAIN FLOOR BEDROOM 3 FAMILY ROOvi MASTER SUITE f frV4 i 1 e,10- w, -4 -lit U. poo -f S'C 11 Co1,.,Pt y wIk 44446 4/0 4‘) al..fiR 1 1)17aw iej+ ret„Iatci IoW 0,444 ) 4y.* CLOSET KITCHEN CLOSET 6 53 A warning sign with minimum'/ inch letters shall be affixed adjacent to the main shutoff valve and shall state the following WARNING The water system for this home supplies fire sprinklers that require certain flows and pressures to fight a fire Devices that restrict the flow or decrease the pressure or automatically shut off the water to the fire spnnkler system such as water softeners filtration systems and automatic shut- off valves shall not be added to this system without a review of the fire sprinkler system by a fire protection specialist Do not remove this sign CLOSET 0 BEDROOM 4 11-0 X 13-5 0 DINING R Ove 11-0 x 11-6 COFFERED CLG SPRINKLER RISER UTILITY BONUS 19-0 VAULTE FOYER 3 CAR GARAGE 0 LIVING ROOV COV'D PORCH STATIC WA1ER PRESSURE 00 ps U »E� ELOO 9LA\ TO SYSTEM WATER FLOW INDICATOR INSULATION PRESSURE GAUGE VAI\ EL00� DRAIN VALVE -- DRAIN PIPED TO EXTERIOR AME3 2000B BACKFLOW PREVENTER To do nenh &frog 15 10 1" WATER METER ALL PIPE TO BE 1 "CP\/ C UNLESS OTHERWISE NOTED. 6" 120v EeII to be IocatelF1 on the exterior approach to home SPRINKLER RISER INSULATION TENTING DETAIL WASHINGTON STATE CERTIFICATE OF COMPETENCY II FIRE PROTECTION SPRINKLER SYSTEMS !Michael D Hutchinson 1166 -0599 -BG Level 2 Evergreen Fare Pr • cbon Inc EVERGF'967 12131 14 General Notes Sprinkler Symbol Legend 1 OWNER TO PROVIDE ADEQUATE HEAT (40F MIN) TO PREVENT SPRINKLER PIPES FROM FREEZING 2 OWNER TO PROVIDE HARD WIRED HOME SMOKE DETECTION SYSTEM 3 CPVC PIPE SHALL HAVE HANGERS 6 —0" c\c AND NOT MORE THAN 6" FROM ANY SPRINKLER HEAD 4 ALL ATTIC PIPING TO BE TENTED WITH BATT INSULATION TO PREVENT FREEZING 5 ALL PIPING TO BE 1" CPVC UNO 6 A 6" BELL TO BE LOCATED ON THE EXTERIOR APPROACH TO HOME IF REQUIRES BY THE LOCAL A H J 7 IF A OUTLET FOR A FUEL FIRED APPLIANCE IS PIPED ON AN EXTERIOR COVERED DECK A INTERMEDIATE TEMP DRY SPRINKLER WILL BE INSTALLED SPRINKLER ORIFICE SIZE TYPE & FINISH RELIABLE RFC 43 16 x16 2 head flaw requirement 26 GPM ® 9 6 psi RELIABLE F1 RES 49 16 x16 FLOW REQUIREMENT 26 GPM CSD 9 6 psi RELIABLE F1 RES 44 SIDEWALL 16 X 20 VICTAULIC DRY UPRIGHT Reliable F 3 QR DRY Sidewall TEMP K FACTOR 155 4 9 155 4 3 155 4 3 200 5 6 155 5 6 EVE�C EEN FRE POTECTI0N I\C PO BOX 998 Puyallup, WA 98371 EVERGFP967LZ Phone (253) 252-7942 TOTAL 24 DATE 9/9/2014 ' REV I DRAWN MH I SHEET 1 OF1 Sheet Title Job Title \T3A 133 7603A Lcnc FIDE fcir X1339 s 160th st TUKWIIQ, WA 98188