HomeMy WebLinkAboutPP - 4002 S 152ND ST - RESIDENCE - PERMITS AND PLANS4002 S 152ND ST ASSOCIATED PERMITS 16-S-116 D15-0302 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Site Address: I(90.Z 36 12404 Tenant Name: A,0 C`;,(M3a Property Owner's Name: J 0 °ALBA. **PLEASE PRINT** 17gNu.ec, a King Co. Assessor's Tax No.: 00'(10 oe 63JZ Suite Number: Floor: New Tenant? riv. Yes ❑ - No Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. G Q Name: �llc<<- (7�1��E� Day Telephone: 4'ZS' eil-ca calor Company Name: • I Si f f Se> tr , T i 0 /451 t L f✓ Mailing Address: Z /0 /9V et) ILM t,vALy Ai. Su I /re 7 �vgu lta WA 78 B 02- /l City State Zip E-mail Address: l G K • .3,eg&E♦�� //rfl((ftur/o. (S, con Fax Number: Contractor's City of Tukwila Business License number: Total number of new/relocated devices or sprinkler heads: 3 Valuation of Project (contractor's bid price): $ 7,00 6 Scope of Work (please provide detailed information): 714,STf' flRGA 3,ie//406Ce%L-C f, es, P 6 i�lcd PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION. AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUiLDINGOWNER 0R AUTHORIZED AGENT: Signature: Print Name: 1 e 13 61 Plan Permit App.doc Date: S --/J-1 A Day Telephone: 412,3"--- ft- yf 0 f 8/22/14 TFD FP Form 8 a INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit tf-- (1302_ /6- s-- /16 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:` —�, ( hCG lAi Ca". Ty a of Inspe n: r`�L Address: ij�a- Suite #: s is)_._ Contact Person: Special Instructions: Occupancy Type: Phone No.: dap proved per applicable codes. Corrections required prior to approval. COMMENTS: &-kokii_L Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: ii Date: cil Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip:: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit Pig-- OAT - PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: y._02Type9f�ction: Sprinklers: Fire Alarm: Hood & Duct: Address: Suite #: Z / �.,.Z ! -r- sr Contact Person: Special Instructions: Phone No.: Approved per applicable codes. orrections required prior to approval. COMMENTS: 4,frtA ts)n AAt /LAW Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspectors ) J5/j' Date: y/fig //, Hrs.: 1. 0 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit -630a- / 6 6 30a-- $-6 l PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Oclovl P -Q -s Type of Inspection: 5r cfniu-re Address: D oo c) Suite #: - I 5 ) Sa rj Contact Person: Special Instructions: Occupancy Type: Phone No.: al. Approved per applicable codes. Corrections required prior to approval. COMMENTS: Abel) -ole Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Date: 6//7//z, Hrs.: r $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Job Name: Location: Drawing Date: Contractor: HYDRAULIC DESIGN INFORMATION SHEET ANTONIO OCHOA RESIDENCE 4002 SOUTH 152ND TUKWILLA, WA 98188 05/09/2016 FIRST FIRE SOLUTIONS 1124 VAN OGLE LANE NW ORTING, WA 98363 Designer: NICK/RICK Calculated By:SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: WOOD FRAME Reviewing Authorities:TUKWILLA Remote Area Number: 1 Telephone:425-891-4909 Occupancy:HOME SYSTEM DESIGN Code:NFPA 13 D Hazard:RESIDENTIAL System Type:WET Area of Sprinkler Oper. Density (gpm/sq ft) Area per Sprinkler Hose Allowance Inside Hose Allowance Outside 650 sq ftl 0.052 330.0 sq ftl 0 gpm 0 gpm Sprinkler or Nozzle Make: QR Model: GL4910 K -Factor: 4.90 Temperature Rating: 155 CALCULATION SUMMARY 2 Flowing Outlets gpm Required: 34.5 psi Required: 52.3 @ Source WATER SUPPLY Water Flow Date of Test Static Pressure Residual Pres At a Flow of Elevation Test 4-2016 80.0 psi 70.0 psi 50 gpm 0" Pump Data Rated Capacity Rated Pressure Elevation Make: Model: 0 gpm 0.0 psi 0 Location: BYRON Source of Information: INSTALLER SYSTEM VOLUME 21 Gallons Notes: wASNINOTON STAT* CeRnrIcATe Or COMPS'RNav rine PROTECTION ppNp,BRSYSTSMS Rick Berger 3928 -0591 -CG Level 3 1st Fire • , L.L.C. TFIt' Dale de a HYDRAULIC CALCULATION DETAILS HYDRAULIC FLOW LOSS QTY DESCRIPTION LENGTH C ID gpm psi TOTALS Hydr Ref W Required at Hyd Area 1 35 35.7 psi Elevation Change 4'0" 1.7 1 Pipe 1" 4Gx21 Allied Galv 2' 120 1.049 35 0.7 1 1" Thrd Back Flow Valve WILKINS " CHART LOSS 35 5.4 1 1-1/2" CPVC 90 Ell 7' 120 1.610 35 0.4 1 Pipe 11/2" PVx15 CSC 10' 150 1.598 35 0.3 1 1" Other Valve METER CHART LOSS 35 6.9 1 Pipe 12" PVx15 CSC 20' 150 1.598 35 0.6 1 Pipe 1" PVx30 CSC 3' 150 1.101 35 0.6 1 1" Thrd Gate Valve Kennedy 0' 120 1.049 35 0.0 Hydr Ref R1 Required at Source 35 52.3 psi Water Source 80.0 psi static, 70.0 psi residual @ 50 gpm 35 gpm 75.0 psi SAFETY PRESSURE 22.7 psi Available Pressure of 75.0 psi Exceeds Required Pressure of 52.3 psi This is a safety margin of 22.7 psi or 30 % of Supply Maximum Water Velocity is 12.9 fps rage .s HYD REF K FACTOR Qa Qt DIA C Pf/ft PIPE FTNG'S TOTAL Pt Pe Pf Pv Pn NOTES: ABBREV. FITTING NAME TABLE NAME C Coupling E 90' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90' Flow Thru Tee ✓ Valve LEGEND Hydraulic reference. Refer to accompanying flow diagram. _ Flow factor for open head or path where Flow (gpm) = K x -\/P Flow added or subtracted Total flow Actual internal diameter of pipe Hazen Williams pipe roughness factor Friction loss per foot of pipe Length of pipe Number of fittings. See table above. Total length (PIPE + FTNG'S) Total pressure (psi) at fitting Pressure due to change in elevation where Pe = 0.433 x change in elevation Friction loss (psi) to fitting where Pf = 1 x 4.52 x (Q/C)^1.85 / ID^4.87 Velocity pressure (psi) where Pv = 0.001123 x Q^2/ID^4 Normal pressure (psi), where Pn = Pt - Pv - Pressures are balanced to 0.01 psi. Pressures are listed to 0.1 psi. Addition may vary by 0.1 psi due to accumulation of round off. - Calculations conform to NFPA 13. - Velocity Pressures are not considered in these Calculations NODE ELEVATION SPRINKLER PRESSURE NUMBER K -FACTOR (FT) (GPM/(PSI^;)) (PSI) 1 1s 2 2S 10 12 13 14 17 18 19 20 21 Al A2 A3 W 18.75 18.00 18.75 18.00 9.50 9.50 9.50 9.50 18.75 18.75 18.75 18.75 18.75 9.50 9.50 9.50 0.08 4.90 4.90 12.5 12.6 12.2 12.3 23.7 24.2 24.8 24.1 13.4 12.9 12.9 14.0 15.2 22.3 26.2 26.3 35.7 ACTUAL FLOW (GPM) 17.4 17.2 Max velocity of 12.95 occurs in the pipe from A3 TO W rage ' MINIMUM ACTUAL FLOW DENSITY (GPM) (GPM/SQ.FT) 16.8 0.05 17.2 0.05 Nodes with "S" indicate a node at the top of a sprig or bottom of drop pendent. The node without an "S" is on the branch. HYD. REF POINT Qa DIA. nCn Qt Pf/ft FITTING TYPES iyco Tire rroaucts PIPE Pt FTNG'S Pe TOTAL Pf rage Pt Pv ******* NOTES ******* Pn PATH 1 FROM HYDRAULIC REFERENCE 2 TO W (PRIMARY PATH) 17.16 1.101 1E 0.75 12.3 12.3 K = 4.90 2S C=150 3.83 -0.3 0.0 17.16 0.051 4.58 0.2 12.3 Vel = 5.84 2 1.101 1T 3.78 12.2 12.2 EqK = 4.92 C=150 9.56 0.0 0.0 17.16 0.051 13.34 0.7 12.2 Vel = 5.84 3.42 1.101 8.26 12.9 12.9 18 C=150 0.00 0.0 0.0 See PATH 3 20.58 0.072 8.26 0.6 12.9 Vel = 7.00 -4.24 1.101 1E 24.68 13.4 13.4 17 C=150 1T 13.39 0.0 0.0 See PATH 4 16.34 0.047 38.07 1.8 13.4 Vel = 5.56 18.19 1.101 1E 12.24 15.2 15.2 21 C=150 3.83 4.0 0.0 See PATH 2 34.53 0.187 16.07 3.0 15.2 Vel = 11.75 Al -15.20 1.101 1E 28.77 22.3 22.3 C=150 3T 32.51 0.0 0.0 See PATH 5 19.34 0.064 61.28 3.9 22.3 Vel = 6.58 15.20 1.101 0.74 26.2 26.2 A2 C=150 0.00 0.0 0.0 See PATH 5 34.53 0.187 0.74 0.1 26.2 Vel = 11.75 1.049 2E 10.75 26.3 26.3 A3 C=120 4.00 4.1 0.0 34.53 0.357 14.75 5.3 26.3 Vel = 12.95 W 34.53 35.7 K = 5.78 PATH 2 FROM HYDRAULIC REFERENCE 1 TO 21 1S 17.37 1.101 1E 0.75 12.6 12.6 K = 4.90 C=150 3.83 -0.3 0.0 17.37 0.052 4.58 0.2 12.6 Vel = 5.91 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) HYD. REF POINT Qa DIA. "Cn Qt Pf/ft Tyco Tire eroaucts FITTING PIPE Pt TYPES FTNG'S Pe TOTAL Pf PATH 2 FROM HYDRAULIC REFERENCE 1 TO 21 CONTINUED rage o Pt Pv ******* NOTES ******* Pn 1 1.101 C=150 17.37 0.052 6.96 12.5 12.5 EqK = 4.92 0.00 0.0 0.0 6.96 0.4 12.5 Vel = 5.91 -3.42 1.101 2T 12.79 12.9 12.9 19 C=150 19.13 0.0 0.0 See PATH 3 13.95 0.035 31.92 1.1 12.9 Vel = 4.75 4.24 1.101 20 C=150 18.19 0.057 22.16 0.00 22.16 14.0 0.0 1.3 14.0 0.0 See PATH 4 14.0 Vel = 6.19 21 18.19 15.2 K = 4.66 PATH 3 FROM HYDRAULIC REFERENCE 19 TO 18 3.42 1.101 19 C=150 3.42 0.003 2.02 12.9 12.9 0.00 0.0 0.0 See PATH 2 2.02 0.0 12.9 Vel = 1.16 18 3.42 PATH 4 FROM HYDRAULIC REFERENCE 17 TO 20 12.9 K = 0.95 4.24 1.101 4E 99.56 13.4 13.4 17 C=150 2T 34.43 0.0 0.0 See PATH 1 4.24 0.004 133.98 0.5 13.4 Vel = 1.44 20 4.24 PATH 5 FROM HYDRAULIC REFERENCE Al TO A2 14.0 K = 1.13 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) HYD. REF POINT Qa DIA. nC" Qt Pf /ft Tyco tire rroaucts FITTING PIPE Pt TYPES FTNG'S Pe TOTAL Pf PATH 5 FROM HYDRAULIC REFERENCE Al TO A2 CONTINUED rage 1 Pt Pv ******* NOTES ******* Pn Al 15.20 1.101 2T 17.50 22.3 22.3 C=150 19.13 0.0 0.0 See PATH 1 15.20 0.041 36.63 1.5 22.3 Vel = 5.17 1.101 9.78 23.7 23.7 10 C=150 0.00 0.0 0.0 15.20 0.041 9.78 0.4 23.7 Vel = 5.17 -6.98 1.101 2T 28.64 24.1 24.1 14 C=150 19.13 0.0 0.0 See PATH 6 8.22 0.013 47.76 0.6 24.1 Vel = 2.80 6.98 1.101 1E 20.63 24.8 24.8 13 C=150 1T 13.39 0.0 0.0 See PATH 6 15.20 0.041 34.02 1.4 24.8 Vel = 5.17 A2 15.20 PATH 6 FROM HYDRAULIC REFERENCE 14 TO 13 26.2 K = 2.97 6.98 1.101 14 C=150 6.98 0.010 8.22 24.1 24.1 0.00 0.0 0.0 See PATH 5 8.22 0.1 24.1 Vel = 2.37 1.101 lE 42.98 24.2 24.2 12 C=150 1T 13.39 0.0 0.0 6.98 0.010 56.37 0.5 24.2 Vel = 2.37 13 6.98 24.8 K = 1.40 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) O Q n�°o =o .12 �D�O coo ZD Fol v10 co cn v m z n m r -o -n330, „°.muN:1 7.1 - m N 0 v CO i co O O O000 COVa 13 m N N Cn V N (p W N ODVcmCno 0 0 CO CO D 0 _._33_. 03 C •• i r« i t 00; (0 (0 13'0 1 3 3 �L.EARANG_ GAS HIGH SFE(,-F'CAT!ONS tri .'.OM 5-115LE -EARTH. :F'_ACES SHALL )12 S=CTON RI004 AS /}__L A5 SE �G t\IA. ST. D5. .A REMOTE SF^JT E LOCATED'4 7 Hi t 3' AND AL _ CC:ME-UST ON 4 -.FROM OUT --1r. `t 10'x0" 'i' K` DN. �F .�{ X{{{C/.�~C_/`•�l .l���<J���h/` iE <x 1 18X18 D3-E912 EN /5 T (N ' I i Al 4 1 4 1" RISE IN WALL TO LEVEL 2 DRY PENDANT HEA IN GARAGE LIa/-ANG AREA ABOVE S TAR ^ -E NEfN-411 -GONG%,AB1 OV_ GRADE 0 -- MIL VAPOR 5ARRIER Q/R 4"GRANtU REINFOR GING IER STRllG T URAL- DG 1T R AR FILL, PROVIDES HR SEPARATION BETEEN LIVING GARAGE (MLLEAND CEILING) 5/&11 TYPE X' GAB ALSO AT ALL -HALLS AND CEILING - --`- F;RE� i APE r'tL��GY�6: �rJINTS r'�T-BEAST- O�IE-GGAT. 3/8" ___--3:1770!-x-34...3" 2o1:4+ -GORE HR RATED D00R-WITri CLOSER--- - ROVlii1= ;(2j b _i l�N�, �Tl ^DiTCTS,IQ 1E l P H!G -4 AND ONE L O'N,-IN-THE--GARAGE %YALL-T0-PROVIDE OUTSIDE COMBUSTION /IND -VENTILATION F S FURNACE 4 IS" i' WL SPACE AG ES NP 71E ?RSR -S A3 ,ro ,L y ti .1 i SPRINKLER RISER, BACKFLOW DEVICE FREEZE 'PROTECTION BY OTHERS e 1 IGNITERS FOR GAS FIRED APPLIANCES IN GARAGE TO ABOVE TOP OF SLAB. _ _ _ _INSTAL (2) 3" DIM. STEEL BOLLARDS FILLED W/ al 18' X18,-,- �E, • 8-2 Q rt 11 C14> 18'X18' 0 C) A-1 1 61 6-9 oiq�;0'1 2/ V""' N cV - 18'X18' 61IS' X 18' v 1 2-4''2 F n�Y" - . .E. 'T A,. 1/ 7-1/4" r/" N/ 0' I* ADS. 1 _' I/�:. !15 HANDRAIL ' L2" OFF- RA: :kIG c.R t1ALL r 2'-i0" ABOVE STAIR -NOSE, STAIR TO GOM~L`•' N IRC. R311.7.52.1 TY 7-- 0, ASN LLI 1/4'1=1' - 011 T Without Comments As Noted in Red Per The Attached Letter A. i -1 -6 _ t � 9 1 4'71-0" 1-0" 25-3 I/2a MAIN FLOOR LIVING AREA :534 SF GARAGE AREA 436 SF PORCH '50 SF TOTAL AREA 1;510 SF These plans have been reviewed by The Tukwila Fire prevention Bureau for conformance with current City stwhdards. Acceptaric, I:; subject to errors and omissions which do rc. sthorize violations of adopted s:E nciaards aria of dines. i .;5y The responsibility for the ,:eouacy of design _u otally with the designer. Ar ditior s; deletio, i rV,SiofS to these drawings after this date will void this acceptance and will require a resubmittal of revised drawing: for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: Cr' — l By: ./ )ldro ret,;$44A 4- Ht.) (644) -i-co- v e 1,8-10 SF Picmt -c,77,1. 206-575 or4 4'F.6r?v1"r,�V give to;S FIFO; Permit and exams ,..2d?._ritss for shut- • down or &v%fion approval. FLOOR FRAMING AT CRAWL SPACE: GONGRE i E IMBED 43" BELO;N SLAE iN 24" DIAM BASE. PROVIDE (2) 22 GA. x 3/4" MTL STRAP TO FASTEN ihH` T O,STRUGTURE. G-EOS, RINCx 14vBRJD ELECTRIC WATER HEATER =N=Rr`' FACTOR (":'BRIO MODE) 2.4 0R "0UAL. OPTION EE .5 FT'S. 1 " SUPPLY BY OTHERS ALARM BELL 6"] FOUNDATION VENT CALCULATIONS PER IRC R403.I PENDENT •' INKLER STYLES PENDENT WITH 401 ESCUTCHEON PENDENT WITH SEMI -RECESSED ESCUTCHEON PENDENT WITH CONCEALED ESCUTCHEON NOTE: ALL CPVC TYPICAL EXCEPT RISER WHICH IS STEEL ALL CPVC PIPE. IS TO BE CONCEALED IN BUILDING CONSTRUCTION FREEZE PROTECTION BY OTHERS 0 C 0 v METER BY OTHERS LLi LLJ V )10 c 0 0 CPUC SAIGLE FASTENER STRIP TYPE MANGER O1HANGER NAIL o roac /0' ,/,.., Ian Mal= tsataOa CPVC DOME FASTENER Egg; APE HANGER O MANGER DETAIL. la WU nwar CPVC DOUBLE FASTENER LYPE HANGER OHANGER DETAIL ate SURGE RESTRAINER FOR PIASTICCPPPE OR CPVC HANGER DETAIL Ma CPVC NUR suPPERT Kara SaffroilitiasW=SPVC S>g 135 GWB CEILING �. w IMF r are are r .re r 7, stars s ata 7 • s • a SCR MI 1saR tri a= Int VIs ala Mar Otrt AVM tsar. arr = tai as va NIA VIII ata INF • V air °ansaistenrV.°r�i': r r r rr r MAP rl re IV t4re ✓ r INF r IV Warr ✓ r INN e ti�r�:�or :avr�aa' MAXIMUM ALLOWABLE DISTANCE OF RESIDENTIAL HEADS IN GWB CEILING AREAS DEFLECTOR ABOVE SURFACE. MOUNTED LIGHT FIXTURES SURFACE ACIUNTED LIGHT FIXTURE 'A' DISTANCE FROM SPRINKLER. TO SIDE OF FIXTLRtE Less than 1 ft One ft to less than 1 ft 6 In. 1 ft 6 In. to less than 2 ft 2 ft : to less than 2 ft 6 b 2 ft 6 In. to less than 3 ft 3 ft to less than 3 ft 6 In 3 ft 6 In. to less than 4 ft 44 ftftto less =Venal 4hnfnt 6f in 3 ft Vital? tto han 3Ft 66 �t gft6htoless'thangain7t 7 ft and greater SEMI -RECESSED FNEAD DEFLECTOR 1 'B' NAXIMUM ALLOWABLE DISTANCE OF DEFLECTOR ABOVE BOTTOM Cr -FIXTURE 0' 0' 1'. 1' 1' 3' 5' 14' VISQUINE VAPOR BARRIER AND BATT INSULATION OVER PIPING TYPICAL IN COLD AREAS CEILING .JOIST OR /KITTEN TRUSS CESID DETAIL FOR ATTIC PIPING TYPICAL NO SCALE EXTERIOR WALL 1:&•,-,-\021=La IN 11111 14 III bur. CPVC COMBO MODNICATION FOR VERTICAL RISER SUPPORT 5ODE CPVC RISER SUPPORT TAIL.. -sass GENERAL NOTES' PIPING IS CPVC TYPICAL EXCEPT SYSTEM RISER WHICH WILL BE COPPER OR GALV. STEEL. ALL CPVC PIPING TO BE CONCEALED IN BUILDING CONSTRUCTION. ALL HEADS ARE LISTED RESIDENTIAL SPRINKLERS ALL WORK SHALL CONFORM TO NFPA 13-D -{- = CENTERLINE OF PIPING ABOVE 1ST FLOOR +- FREEZE PROTECTION FOR ALL PIPING BY OWNER ALL ELECTRICAL WIRING BY OWNER /1' TO SPRINKLERS SEE PLAN Qt 1. 1/2' PV UNDERGROUND BY OTHERS C� 1' LUSTED VERTICAL BACKFLOW PREVENTOR Q Q 1' RISER ASSEMBLY & DRAIN WITH FLOW SWITCH 01' TO SPRINKLERS ELECTRIC ALARM BELL FOR SPRINKLERS /FLOOR 0 j 1" SPRINKLER RISER IN GARAGE AREA RISER ELEVATION NO SCALE 384 SF. 426 SF 50 SF. SF. ) / APPRO (MATE WORK/CLEARING o LIMITS=0.f5ACRES CZi 20 PRO ERTi ONE 80.75' S 88° NOTE: CONNECIT ROOF DRAINS TO EXIST CATCH BASIN 29LF 6" PVC\ UNSMIte tr. 20' EXIST \ ASPHALT DRIVEWAY APPROXIMATE LOCATION OF SILT _,_P-ENCE ACT.UAL LOCATION TO BE' DE IERINED IN FIELD AS CONSTRUCTION PROGGESSES — REMOVE EX 1 CHAIN LINK 1 FENCE EX. CHigIN LINK FENCE 11. \\ _SL__452nd \\ CD \\ EXIST TREE STRtp- (TYP) AP OX. LOCATION (TY'N UNDERGROUNI) GAS -LINT TO LOT 2 (NEEDS .T•osE RELOCATED TO 1TY PA PROPERTY LINE EX. SSEW RIGHT FIRE CONSTRUCTION ENTRANCE EX. CATCH _ BASIN (TYP) WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPinioncLun win:swats Rick Berger 3928-059 -CG Level 3 TFI OF NOTES REVISIONS SPRINKLER SYMBOLS c-, FIRST FIRE SOLUTIONS 1124 VAN OGLE LANE NW ORTING, WA 98363 425 891 4909 ANTONIO OCHOA RESIDENCE 4002 SOUTH 152ND STREET TUICWILLA, WA 98188 NFPA 13-D SPRINKLER A 0 at 0 "um. mumiN DATE DESCRIPTION • PERMIT NO. CONTRACT NO. -. APPROVAL DRAWN BY NICK/RICK 1ST FIRE ISYM CNT POSITION FINISH TEMP K NPT SIN MFG. MODEL# - DATE 05/09/2016 1 (g14 4 PEND CHROME 155 5.60 1' GL5635 GLOBE GL5635 FP 1 of 2 DIRECT \/SIT GA5 HIGH _EFFiGENGY FIRE P! AGE - O 5E INSTALS . ER MANLFACTUIRE SPEC FICATIONS N!/ 20" NIDE (MIN.) NON-COM ;UST( LE HEARTH. FACTORY -SU' ILT FIREPLACES SHALL COMPLY V'UTH IRC 20L2 SECTION RI004 AND NAG 5i—iS-402 AS lnE! L AS E_ CERTIFIED AS M_FETIN6 NA. ST. EMISSIONS STANDARDS.. A REMO i:E SHUT OFF VALVA SHALL E'E LOCA i ED NIT FN 3' OF THE FI; ..E. PLACE AND ALL COMBUSTION AIR SHALL E TAKEN FROM OUTDOORS'. 421-0" 10'-10" 41-0 11 -?" V5_0_ _0_. rot- i t 1-1012 1 L- STER BT -/////////////7 /‹..22.-1/./.y/ ///////X/2„/ �4 vi 1/ \ V. //// //./- — — —- / 18'X18' Ind I?2' ; `r'- l u 15- _t 11 u ..J 18'X d8' ICS` L..7 2 / ..-0 •i7 1 . W' .1 CY 7 A1_ CV _r; • 1-7" 9-9 18'X1'8 }>_ 18X18' I'". REMOTE- 44-1 /411-1' =P. ✓*._:./. 2 -LL. 001.�I A A .M.�—,� 1,344 SF Aff-------14 — 0" 7-'0LN:.=T:ON DRAIN: :1 D i.: i -`E T _R F -'R . 71`iQQT4 , J AL_E i _FFPROVED DRAINAGE SOURCE TOF OF SUE O OP 0 MASTER SUITE -7Y717, 1/ .5 YENTEC ATTIC FR=ir4.3RIC,4-.TED FRE Ei INEER'TD TRUSSES it. I ^� /' HAI I BATH %t ' R 49 INSULATION TYP. I 11 ISEDROOI' i K. BEAM FER STRUCTURAL PLANS =R0VIDE i HR .,EFAR=T'ON 5ETUEEN _f`/INC = GAR AGE S%8' =_ `X' G. E, ALSO AT CE!L.NG. K = 1 ' SL=S ON GRAD- =ER SRUC I URA_ DILL ., — OVER 4' CRUSEDI ROCK EASE VAPOR E4RRIER �7 =L_ =OF - =DOTING S / -O O\, ER JND IS T SRBED SOIL I� OPEN TO DINING POST a, BEAM PER PLAP OPEN TO LIVING SENTIC1' 11. NE/N NOOD FRAMED STAIRS N/ .5 RISERS @ 7-1/4" NV :0" TREADS. I L'2" HANDRAIL OFF RAILING OR'AA- 2'-i0' A___ -i0' .AE0'/E STAIR NOSE. STAIR TO COMPLY N! IRC TOP OF PLATE VENTED ATTIC PREFABRICATED FRE.=NGINEERED TRUSSES TOP O`SELOOR BEAM PER STRICTURAL. FLANS 112 CEDAR E. OR CEMENT HARD! PANEL TYF. O-- OF SUE LOOK CO TOP _ W TOP OF SUBFLOOR e-1 YENTA ATTIC L FRAF ^ RIC^TE FR= E GINE=q:- %• R 49 'NSUL.=TION TYF 2x6 /. T =RIOR iN.StiLLAT/..7\! TRUSSES II 1 VEDR ROO' '3 2x6 EXTERIOR WALL NSUL AT:ON---__ • 11 -r FOUNDATION DRAIN: - 4' DIAMETER FERC, SMOOTI-! WALLED - FIFE TO APPROVED DRAINAGE SOURCE TIP. N/STUD'' FOE; 7:2 KITCHEN f l A 1i POST I FOOTINGS FER STRUCTURAL PLANS - s CT I O\ 1/4"=1i s 0" 2x5 EXTERIOR UAL: R-2 'NSUL .TION A.1) AAMVAN/ FLOOR FRAMING- FER S T RUC T .1RAL PLANS R-30 INSULATION (TYF). 6 MILL MOISTURE BARRIER (T F). TOP OF Pi OF OF SUBFLOOR I Oi 0 TOP OF SUBFLOOR /1 WASHINGTON STATE CERT!!ICATE or COMPETENCY FIRE PROTECTION SPRIHKLERSYSTEMS Rick Berger 3928-059 -CG Level 3 Fire ns, L.L.C. 1DF 6-3- a Sl�aat it--ri4• Date W 2' 4' n_ ' 8' 10' 12' 14' 16' 18' NOTES REVISIONS SPRINKLER SYMBOLS DATE DESCRIPTION SYM ICN T 'PDSITION FINISH TEMP 1 K 1NPT (SIN 'MFG: IMDDEL# 129 PEND (WHITE 155 ( 4,90 11/2' - GL4910 (GLGBE 1GL4910 (g" k IPEND (CHROME 155 15.60 11' ( GL56351GLDBE 16L5635 FIRST FIRE SOLUTIOI \ 1124 VAN OGLE LANE NW ORTING, WA 98363 425 891-4909 ANTOMO OCHOA RESIDENCE 4002 SOUTH 152ND STREET TUKWILLA, WA 98188 a NEPA 13-D SPRINKLER PERMIT NO. CONTRACT NO. APPROVAL DRAWN BY SCALE NICK/RICK 1 DATE 05/09/2016 ROMEO FP 2 of 2