Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 4432 S 150TH ST - RESIDENCE - PERMITS AND PLANS
4432 S 150TH ST ASSOCIATED PERMITS 12-S-211 D12-150 INSPECTION NUMBER INSPECTION RECORD Retain a copy with pe 12--s- a1► D1 - is -o PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Proj-ct;� -�i' ' : �1 _ J -, Inds Type of Inspection: e 4---, A 1 3Q.( )1f Address: Li &I 3a, Suite #: 15O4'1- Contact Person: Occupancy Type: Special Instructions: Phone No.: proved per applicable codes. Corrections required prior to approval. COMMENTS: se oK i ers — o (L Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:% „ S-'2- Date: (2 - / I , (5-Hrs.: t $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with per « LSOa 1Jr�}- /So PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project:— 5m \ I� Sprinklers: T e of Inspe qn: kr-e. , rvvrC_, Address: Li L( 3 a_ Suite #: S wO 4- Contact Person: Special Instructions: Occupancy Type: Phone No.: J1pproved per applicable codes. Corrections required prior to approval. COMMENTS: e_ ct YAk- Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: fkt tea— Date: / z) /KJ/_ Hrs.: 1 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit i� - PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project:�� �! R��\0��� Type Inspection: Address: 3 a Suite #: S /c2). Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: O - ^T b Co L- r 1-1171 Ora o/ Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: •,-t1'7 Date: //)/97/8 Hrs.: „2. $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 DATE: 9/20/2012 C:\program files\HRS Systems\hhouse33\STEVENS .rdf Page 1 EVERGREEN FIRE PROTECTION, INC. 10509 64th AVENUE E PUYALLUP,WA 98373 RESIDENTIAL SPRINKLER SYSTEM HYDRAULICS CALCULATION REPORT FOR Stevens Residence Tukwilla 4432 150th St. Date: 9/20/2012 File No: Data File Name: STEVENS .rdf SPRINKLER SPACING 256.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 16.0 ft. Min. Dist. Bet. Spklrs: 8.0 Max. Dist. Spklr. to Wall: 8.0 ft. SPRINKLER SPECIFICATIONS Mfr: Reliable Descr: RA0612 RFC43 F1 Conc .Pend.(16x16) K=4.30 Calculated K Factor for Arm -Overs & Drops: 1.0 ft. x 1.101 in. Drop: K=4.26 (Incl. 1 Tee) 0.0 ft. x 1.101 in. Arm -Over: K=4.25 (Incl. 1 Tee & 1 Ell) PIPE SPECIFICATIONS Type: CPVC S-40 HWC: 150 WATER SUPPLY Source: Public Test Date: By: Static: 95.0 psi Resid: 0.0 psi Flow: 0.0 gpm Public Main Size: 0 in Domestic Demand: 0.0 gpm at node number 0 SPRINKLER DEMAND No.Spklrs. Min Spklr. Press. Node Total Avail. Req'd Flowing Flow (psi) No. Flow Press. Press. 1 13.0 9.3 1 13.0 95.0 42.3 2 13.0 9.3 1 26.2 95.0 56.4 REVIEWING AUTHORITY City of Tukwilla DATE: 9/20/2012 C:\program files\HRS Systems\hhouse33\STEVENS .rdf Page 2 PIPE & NODE DATA P # END LEN FIT. HWC NOD DIA EQV.LN RESULTS OF ANALYSIS FIXD LOSS EL SP PUMP (FT) (K) * FLOW ANALYSIS * 1 sprinkler flowing * 2 sprinklers flowing * * *DISCH FLOW PF PT *DISCH FLOW PF PT * (GPM) FL/FT PE (PSI) * (GPM) FL/FT PE (PSI) * * 1 1 10.00 R ---- 40.0 4.26 13.0 -13.0 0.34 9.3 13.0 -13.0 0.34 9.3 150 2 1.101 1.0 ---- 40.0 4.26 ---- -0.03 0.00 9.7 13.2 -0.03 0.00 9.7 2 2 6.00 B ---- 40.0 4.26 ---- -13.0 0.34 9.7 13.2 -26.2 1.24 9.7 150 3 1.101 5.0 ---- 40.0 ---- ---- -0.03 0.00 10.0 ---- -0.11 0.00 10.9 3 3 40.00 2B7R ---- 40.0 ---- ---- -13.0 1.75 10.0 ---- -26.2 6.40 10.9 150 4 1.101 17.0 ---- 40.0 ---- ---- -0.03 0.00 11.7 ---- -0.11 0.00 17.3 4 4 10.00 B ---- 40.0 ---- ---- -13.0 0.46 11.7 ---- -26.2 1.69 17.3 150 5 1.101 5.0 ---- 30.0 ---- ---- -0.03 4.33 16.5 ---- -0.11 4.33 23.3 5 5 7.00 2LR ---- 30.0 ---- ---- -13.0 0.55 16.5 ---- -26.2 2.02 23.3 150 6 1.101 11.0 ---- 30.0 ---- ---- -0.03 0.00 17.1 ---- -0.11 0.00 25.3 6 6 10.00 L3R -5.0 30.0 ---- ---- -13.0 0.55 17.1 ---- -26.2 2.02 25.3 150 7 1.101 8.0 ---- 20.0 ---- ---- -0.03 4.33 27.0 ---- -0.11 4.33 36.7 7 7 300.00 4L -5.0 20.0 ---- ---- -13.0 1.64 27.0 ---- -26.2 6.00 36.7 150 8 1.598 28.0 ---- 0.0 SRCE ---- 0.00 8.67 42.3 ---- -0.02 8.67 56.4 Legend: P - Pipe # DIA - Pipe Diameter EQV. LN - Pipe Equivalent Length PUMP - Pump Pressure SP - K -Factor FLOW - Flow Rate PF - Pressure Loss due to Friction PT - Total Pressure at Node Node Notes Pipe Notes LEN - Pipe Length FIT. - Pipe Fittings FIXD LOSS - Fixed Loss Device EL - Node Elevation DISCH - Discharge in gpm FL/FT - Friction Loss per Foot PE - Pressure Loss due to Elevation Fitting Code Letters: E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, S=SwgChk, G=GatVly, X= X, DATE: 9/20/2012 C:\program files\HRS Systems\hhouse33\STEVENS .rdf Page 3 The maximum velocity of water flow occurs in pipe 5 at 4.38 ft/s with 1 sprinkler flowing. The maximum velocity of water flow occurs in pipe 6 at 8.84 ft/s with 2 sprinklers flowing. PIPE FITTINGS TABLE Pipe Table Name: standard.npt PAGE: C MATERIAL: CPVC S-40 HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.101 1.00 5.00 5.00 1.00 1.00 8.00 2.00 0.00 0.00 0.00 1.598 2.00 7.00 8.00 1.00 1.00 14.00 3.00 0.00 0.00 0.00 Sprinkler system has been hydraulically calculated with the HASS HOUSE 3.2 computer program (License No. R609099990) to provide an average imbalance of 0.010 gpm at each node and a maximum imbalance of 0.01 gpm with one sprinkler flowing, and 0.010 gpm at each node and maximum imbalance of 0.01 gpm with 2 sprinklers flowing in accordance with NFPA 13 and 13D or 13R. HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 DATE: 9/20/2012 C:\program files\HRS Systems\hhouse33\STEVENS .rdf Page 4 WATER SUPPLY CURVE CC P R E S S U 105.0 94.5 84.0 73.5 63.0 R 52.5 E ( 42.0 P 31.5 I 21.0 10.5 A CB CD 0.0 I I I I I I I I I 04 8 12 16 20 24 28 32 36 40 FLOW (GPM) Static = 95.0 psi (fixed pressure) (1 sprinkler flowing) (2 sprinklers flowing) A = Available Water Supply 95.0 psi @ 13.0 gpm B = Required Water Supply 42.3 psi @ 13.0 gpm C = Available Water Supply 95.0 psi @ 26.2 gpm D = Required Water Supply 56.4 psi @ 26.2 gpm 47,4 vv:,ofut Con As Noted i{ e:J Per The At cher: ' niter ll - PATIO STOOP DEN 11-6x11 To upper floor FAMILY RM. DIRECT VEN S F.P. (INSTALL PER ANUF.SPECS.) Up from lower floor These plans have been reviewed by Tukwila Fire revention Bureau for conrorma .-€_ t , , ; current CO standards. Acceptance is sUbi :Ci :,., .:.',-.I: and omissions which do n.;t o; adopted standards and ordin nc2s, :- I.. ;r .:". iiia for the adequacy of design :est tot::: :`•`(i �' ::; �'zrler. Additionsf'deletions e.'=r (t)C1.!:(-': drawings after this date will. vold thin. acceptance L•>-lci vvi!i require a resubmittal of revised drawings for suot.; quen1: approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevendon Bureau. Date: ,-.1.(0 (o - ea- by: ILE 1 13v:xe-� Mow) +es')- 15:7:5:: .TUKWILA REATMENTPleaseca2054407 and give this Fire Permit No, and exact address for shut- /?- 9.11 down hut`- down or restoration approval. 6.5.3 A warning sign, with minimum % inch letters, shall be affixed adjacent to the main shutoff valve and shall state the following: WARNING: The water system for this home supplies fire sprinklers that require certain flows and pressures to fight a fire. Devices that restrict the flow or decrease the pressure or automatically shut off the water to the fire sprinkler system, such as water softeners, filtration systems, and automatic shut-off valves, shall not be added to this system without a review of the fire sprinkler system by a fire protection specialist. Do not remove this sign. 0 FURN. PANTRY Sprinkler riser COATS Water Heate sidewall sprinkler I 1 3/4" SOLID COE w/SELF CLS`R. 3070 C;O. TO SYSTEM \ARCH GARAGE PARLOR 15 x 14-3 (OPTIONAL) DIRECT VENT GAS F.P. (INL PER MANUF.SPECS.) N 'ER FLOW INL ';ATOR PRESSURi GAUGE VENT SEE TFRU F.P. Spare sprinkler head cobr.>;t 27 x 21-6 KING 11 x 14-6 l v —DRAIN VALVE AMES 2000B BACKFLOW PREVENTER 1.5" o/o,' 'b/d©41.PI✓. 140/0 ,' rb/b Pao 1 _'if FIRST FLOO PLAN Scalae :1/ Copyright 2000 Northwest ome Designing Inc. 1`3 CONS FLOOR ~f` LA Sc • 1/4 -0' General Notes Sprinkler Symbol Legend 1. OWNER TO PROVIDE ADEQUATE HEAT (40T. MIN) TO PREVENT SPRINKLER PIPES FROM FREEZING. 2. OWNER TO PROVIDE HARD WIRED HOME SMOKE DETECTION SYSTEM, 3. CPVC PIPE SHALL HAVE HANGERS 6'-0" c\c AND NOT MORE THAN 6" FROM ANY SPRINKLER HEAD. 4. ALL ATTIC PIPING TO BE TENTED WITH BATT INSULATION TO PREVENT FREEZING. 5. ALL PIPING TO BE 1" C.P.V.C. U.N.D. 6. A 6" BELL TO BE LOCATED ON THE EXTERIOR APPROACH TO HOME. 7. IF FURNACE IS LOCATED IN THE ATTIC SPACE A DRY UPRIGHT WILL BE LOCATED NEXT TO THE FURNACE. 18627211, SYM SPRINKLER ORIFICE SIZE, TYPE & FINISH QU AN TEMP K FACTOR RELIABLE RFC 43 16'x16' FLOW REQUIREMENT 26 GPM r, 9.6 psi RELIABLE F1 RES 49 16'x16' FLOW REQUIREMENT 26 GPM 0 9.6 psi RELIABLE F1 RES 44 StDEWALL VICTAULIC DRY UPRIGHT 28 0 155' 4.9 155' 4.3 155' 4,3 200' 5.6 VIRG-E\ FRE DROTECTIOI\ 10509 64th Ave E. Puyallup, WA 98373 evergfp967Iz Phone: (253) 848-0146 Reliable F 3 QR DRY Sidewall 155' 5.6 I\C Sheet Title 77Title 13D • 300' WATER METER (7i) DRIV<LF R S Stamp 133 FIR STIV S L\S R KL -SIS 44, 13% iv A :**0.°S11111151°W yory 1 °68h Decemb°l l,' =R SLA\ \C- .2213121211,210,021,0111., TOTAL DRAWN: MH SHEET: L32 1507 T._ /<WI L L A ST PAID ".'"02012 I: 'reWILA FIRE