Loading...
HomeMy WebLinkAboutPP - 4638 S 150TH ST - UNKNOWN - PERMITS AND PLANS4638 S 150TH ST ASSOCIATED PERMITS 95-5-150 6" ELEC BELL GARAGE SEE RISER DETAIL BELOW 134 4,1 PORCH 7-9Y MASTER BATH "WASH/DRY _ r 1X 1 m m 5-134 1 0-1034 134 BEDROOM 6-634 STRAP DN TO THE TOP OF THE JOIST W/ #13 CLOSET 1 6-634 6-734 BEDROOM 6-714 LINEN CLOS 1-8 1-8 CLOSET N BATH • 136 / 1X PORCH 34i 1 SYSTEM DESIGN PER NFPA 13D SYSTEM REQUIRES 2 HEADS FLOWING (SEE CALC NOTES) HEAD LOCATION PER NFPA 13D PARA. 4-6 & EXCEPTIONS 1 THRU 5 CEILING SYSTEM SENSOR T -TAP 1X WATERFLOW SWITCH (INSTALL IN 1X TEE) X"GAUGE 1" DRAIN LINE 1" BALL VA. 1X" SPRINKLER RISER 134"AMES SILVER BULLET 2000 SS DOUBLE CK.VA." REMOVE HANDLES PER T.F.D. (<< V\ 134x0-4 2-234 7-23 72- STRAP DN TO THE TOP OF THE JOIST W/ #13 7-234 4 634 8 8Y / PANTRY 4-0% • / / 1 1-1 034 Oi 0 z 0 3- Q cc (n = I BEDROOM 8-6 a 1-8 6" ELEC BELL TO DOMESTIC PIPING SYSTEM 1Xx1 "x134 TEE PIPE DRAIN OUTSIDE FLOOR BUILDING MAIN SHUTOFF /DOMESTIC FROM CITY MAIN 1" METER AT STREET RISER DETAIL FIREPLACE WINDOW EARTHQUAKE BRACE IS SERVED BY SHORT STRAPS TO THE JOIST S. 150TH ST. SITE PLAN • Mit ) 8-8 CALCULATIONS: SYSTEM DEMAND = 24 GPM AT 46.83 PSI AT STREET SYSTEM DEMAND AT FLOOR = 24 GPM AT 21.40 PSI CALCULATIONS ARE BASED ON DYNATHREAD PIPE FOR PIPING INSIDE THE HOUSE. POLYBUTE PIPE WAS USED IN THE CALCULATIONS FOR THE UNDERGROUND STATIC PRESSURE = 67 PSI RESIDUAL = 20 PSI @ 3500 GPM USE RELIABLE HEADS - MODEL ZX-RES/2 PENDENT RESIDENTIAL 16'x16' = 12 GPM AT 8.6 PSI EACH SPRINKLER HEAD FOR TWO 'HEADS Pitu.rrfi-sf ,atte.i:La 41,17 t .04441 4e1 ACCEPTED WITHOUT COMMENTS. ;SAS NOTED IN RED PER THE ATTACHED LETTER The drawings affixed hereto have been reviewed and accepted by the City of Tukwila Fire Dept. A-Jditions, delsti,ms or revisions to thess dr.iwings after this date will void this acce?t:inca anti will require a resubmittal of revised drawings. Final acceptance is subject to field - inspection by a representative of this department DATE: Co BYF i $7O CITY OF TUKWILA 575-4407 FILA BOJ BB = BOD = TOB = TOS = AFF = FOW = NTS = PRV = RM = SP = NIC = DO = UON� ATR = TOE = TBE = TxG = GG = PP = #1 #2 #3 #4 #5 #6 ABBREVIATIONS BOTTOM OF JOIST BOTTOM OF BEAM BOTTOM OF Df CK TOP OF BEAM' ' - TOP OF STEEL ABOVE FINISH FLOOR FACE OF WALL NOT TO SCALE PRESSURE RED. VALVE ROOF MANIFOLD STANDPIPE NOT IN CONTRACT DITTO UNLESS OTHERWISE NOTED ALL THREAD ROD THREAD ONE END THREAD BOTH ENDS THREAD BY GROOVE GROOVE x GROOVE POLISHED x POLISHED HANGER LEGEND U—HOOK COACH SCREW ROD & RING CEIL FLANGE, 1/4" LAGS EYE ROD, FASTENER & RING U -BOLT (PER DETAILS) KWIK BOLT,ROD COUP, R&R #7 POWER DRIVEN STUD, R & R #8 TOGGLE NUT, ROD & RING #9 #10 REG C -CLAMP, RETAIN STRAP TOP BM C-CLMP, STRAP #11 TRAPEZE (SEE DETAIL) #12 SIDE BEAM BRACKET #13 SHORT STRAP #14 EYE NUT,ROD,RING #15 #16 PIPE SIZING & SPACING CONFORM TO NFPA PAMPHLET #13 STANDARDS FOR HAZARD OCCUPANCY ALL MATERIALS & EQUIPMENT TO BE NEW & UL/FM APPROVED OWNER TO PROVIDE ADEQUATE HEAT TO KEEP PIPE FROM FREEZING 0 LTJ w J -J OD >-- Ul a 0 U CC 0 0 1- t-- 0 0 O cc 0 RIGID VIC COUP 2 -WAY EARTHQUAKE BRACE 4 -WAY EARTHQUAKE BRACE ELEV. IN INCHES BELOW DECK 4+ 4, X z O a 2 LJ f-- tO 2 TUKWILA FIRE DEPARTME VT Please call: 575.4407 and give this job No. 9S- / /so and exact address for shut- down_ or restoration approval. MISWI D Z 6 PROPERTY TAX ACCOUNT : 004200-0226-08 I MEWL, i -ii JUN E,29 -N � f j d^.r SPRINKLERS SPRINKLERS -J 0 1 - UJ 0 zO z D U w 0 00 a DRAWING TITLE SPRINKLER PIPING O_ <0 ❑O❑ 1 z 8 0 air 0 a N U z 0 W 0 1 0 V 1 7