Loading...
HomeMy WebLinkAboutPP - 11133 51ST AVE S - MAUNA KEA APARTMENT / BEACON HOMES - PERMITS AND PLANSMAUNA KEA APARTMENTS 11133 51STAVES ASSOCIATED PERMITS 14-F-136 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 0780000010 Site Address: 11133 51st Ave S., Tukwila, 98178 Suite Number: Floor: Tenant Name: Beacon Homes New Tenant? ❑ - Yes - No Property Owner's Name: Beacon Homes Mailing Address: PO Box 22998 Seattle WA 98178 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Casey Walsh Day Telephone: 206.331.6206 Company Name: Guardian Security Systems Mailing Address:1743 First Ave South, Seattle, WA 98134 E-mail Address: cwalsh@guardiansecurity.com City State Zip Fax Number: 206 628.4990 Total number of new/relocated devices or sprinkler heads: 1 Valuation of Project (contractor's bid price): $ 250 Scope of Work (please provide detailed information): Installation of an AES radio transmitter to monitor the existing FACP PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signatur Print Name: Casey Walsh Plan Permit App.doc PAID JUN 1:7 2014 06/17/2014 FIRE Date: TUKWILA 206.331.6206 Day Telephone: 1/2/13 TFD FP Form 8 • 1 GUARDIAN SECURITY Seattle- Tacoma - Poulsbo - Bellingham 1743 First Avenue South Seattle, WA 98134 06/17/2014 City of Tukwila Fire/Hazard Prevention Bureau RE: Installing AES Radio Transmitter Guardian Security Systems would like to install an AES Radio Transmitter to monitor the existing FACP. This is a non -addressable system. A heat detector above the FACP will be present. Northwest Alarm Central Station located at 1743 1st Ave S., Seattle, WA 98134 will be monitoring the following address: Sincerely, Casey Walsh Permit Specialist cwalsh(a�guardiansecurity. com 206.331.6206 Enclosure NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and tprm;n7t!,-,P ""n Beacon Homes 11133 — 51st Ave S. Tukwila, WA 98178 Tel: 206.622.6545 Fax: 206.341.9928 TUKWILA FIRE DEPARTMENT Please call 206-575-41O7 and give this Fire Perrnit No. lam! -F I3 and cx,ct dc`s for shut- down or rostor-u on approval, Tor7 tr Without Comments As Notes l;) Red 0 Per The Attache° Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subjec., arrors and cimissions which do not authori r o►. tiory , of acopter: :andards and ordinances. The responsibility for the adequacy of design rests totally w!tn the designer. Additions, deletiorrs or revisions to these dravtAnc. eti this date will void this acceptance ano mil require a resubmittal of revised drawings fo ;uo:.A; siert u9prr',. 'Thal acceptance is subject to Melo test and inspection r ne Tukwila Fire Prevention Burreeayu., By: y ' `� • 7788F/7744F Series Wireless Fire Alarm Communicators for AES-InlliNet Model 7788F USTED Advanced Wireless Alarm Monitoring The AES-IntelliNet mesh radio network offers unmatched reliability and speed in delivering wireless alarm signals to a central station without third party fees or reliance on networks owned by companies outside the security and fire alarm industry. AES-7788F/7744F Series Smart Subscriber Transceivers provide the wireless communication link between the fire alarm panel and the central station receiver. The 7788F/7744F Series is ideal for most commercial fire alarm applications. Each 7788F/7744F Series Subscriber is housed in a full sized, red, locked, steel cabinet and supports a range of alarm panel inputs including EOL fire, EOL supervised, and direct voltage from the panel (non -fire applications). Supervised Operation AES Smart Subscribers offer fully supervised operation that includes moni- toring of operating power (both primary AC power and battery backup) and the connection to the radio network. Each Subscriber "checks in" with the AES central station receiver at least once every 24 hours. The supervision check in time can be set for as often as once per minute and, because the central station owns the wireless network, there is no additional cost for air time to transmit supervisory signals. Full Data Reporting from Alarm Panel Digital Dialer Models 7788F-ULP and 7744F-ULP come equipped with an IntelliPro Fire Full Data Module (AES -7794) which enables reporting of full alarm data captured from the fire alarm panel's digital communicator. IntelliPro Fire supports most alarm communication formats including Contact ID, Pulse, as well as Bosch Modem Ile and Modem 111a2. AES IntelliNet CORPORATION For Alarm Mon Loring Features — All models • UL Listed commercial fire alarm appli- cations. • Meets NFPA 72 requirements • Direct reporting to AES receiver across IntelliNet wireless mesh net- work • Each Subscriber acts as transmit- ter/receiver/repeater • Simple and fast activation on network • On board status LEDs for easy set up • 8 programmable zone inputs — 7788F • 4 programmable zone inputs and 4 reverse polarity inputs — 7744F • Easy programming via AES handheld programmer or PC • Rugged metal housing ideal for any commercial fire alarm application Models 7788F/7744F-ULP with IntelliPro Fire also includes • IntelliPro Fire transmits full alarm data from virtually any fire alarm panel dig- ital communicator • Alarm format support for Contact ID, Pulse, or Bosch Modem Ile or Modem 111a2 • Easy installation in AES subscriber • Operates in applications with or with- out a phone line Wireless mesh networking is an innovative technology adopted by many industries with applications that need to communicate data over a large geographic area with a high level of reliability at a low total cost of ownership. The advanced design and 2 -way communications capability provides easy installation, expansion, and management when compared to alter- native communication methods, both wired and wireless. 7788F/7744F Series Technical Specifications 7788F/7744F Series Subscribers Dimensions • 13.25"H x 8.5"W x 4.3"D (34cm H x 21.5cm W x 11 cm D) Weight • Approx. 7 pounds (3.2 kilograms), excludes battery. Radio Frequency • Standard Frequency Range: 450-470MHz (others available) • Output Power - 2 Watts (others available) Antenna • Included 2.5 db tamper resistant antenna mounts on enclosure • Multiple remote antenna options available Power Input • 16.5VAC, 40VA (transformer not included) Backup Battery • Will charge 12V battery up to 7.5 AH. Requires 12VDC 7.5 AH battery for UL 864. Alarm Signal Inputs (subscriber) • 7788F — 8 individually programmable zones • 7744F - 4 individually programmable zones and 4 reverse polarity inputs UL Standards • UL 864 Edition 9 — Standard for Control Units and Accessories for Fire Alarm Systems • UL 365 — Standard for Police Station Connected Burglar Alarm Units and Systems • UL 1681 — Standard for Central Station Burglar Alarm Units Antenna Cut / Communication Trouble Output • Fomi C relay; fail secure; rated for 24 VDC 1A resistive Reset Button • Located on main circuit board. Operating Temperature • 0° to 50° C (32° to 122°F) Storage Temperature • -10° to 60° C (14° to 140°F) Relative Humidity • 0 to 85% RHC, Non Condensing AES -7794 IntelliPro Fire Input / Output Connections • RJ11 connection to AES subscriber for module data and power • RJ11 connector for Handheld Programmer/PC programming RJ31X Telco connections - T and R both in and out via terminal strip and RJ45 • Alarm Panel digital communicator T and R both in and out via terminal strip and RJ45 • Trouble output: Form C relay detects if Subscriber is off the network Alarm Formats • Support for Contact ID and Pulse formats as well as Modem Ile and Modem 111a2 converted to CID Size • 2.8 x 5.0 inches (7.1cm x 12.7cm) Power Requirements • 12 VDC nominal - primary and backup power provided by the AES 7788F/7744F or other Subscriber AES-IntelliNet" is the industry leader in delivering high quality wireless mesh networks to the fire and security industry in commercial, corporate, govemment, and educational applications with its broad line of products and advanced network management tools. Users of AES-IntelliNet networks have gained significant revenue, communications, and cost advantages while meeting the high stan- dards of reliability required for the fire and security industry. AES-IntelliNet alarrn monitoring systems are deployed at hundreds of thousands of locations in over 150 countries. COFrPORATtON IntelliNet For Ataroe Monitoring For more information Call 800 -AES -NETS (800-237-6387) AES Corporation I 285 Newbury Street I Peabody, MA 01960 USA Tel. +1 978-535-7310 1 Fax +1 978-535-7313 1 Email info@aes-intellinet.com Web www.aes-intellinet.com SAES IntelliNet CORPORATION For Alarm Monitoring How to Order Model Description 7744F 4 Zone Fire Alarm Subscriber with 4 reverse polarity inputs 7744F-ULP 7744F Fire Alarm Subscriber with IntelliPro Fire full data module 7788F 8 Zone Fire Alarm Subscriber 7788F-ULP 7788F Fire Alarm Subscriber with IntelliPro Fire full data module Optional Accessories 7041E 7794 LISTED 801 Subscriber Handheld Programmer IntelliPro Fire Full Data Module Copyright 2011 AES Corporation AES intetfiNet is a registered trademark of AES Corporation reF-7744F$77/11R3 SECAMM 170 0 , CA a IPPA 0