HomeMy WebLinkAboutPP - 4640 S 148TH ST - UNKNOWN - PERMITS AND PLANS4640 S 148TH ST
ASSOCIATED PERMITS
18-S-146
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
PERMIT NUMBERS
CITY OF TU ILA FIRE DEPARTMENT
206-575-4407
Project:
I IA IS -4/\
Sprinklers:
Fire Alarm:
Type of I pecti n:
Address:- ' //
--4Z323,1---2(\
Suite --4Z323,1---2(\`g
�
��
5,,. I �'�
Contact Person:
Special Instructions:
Phone No.:
\Opproved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector: r.
—// ,
fr Z z
Date:
`�
50
/
Hrs.:
1--6
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word/Inspection Record Form.Doc
3/14/14
T.F.D. Form F.P. 113
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
PERMIT NUMBERS
CITY OF TU ILA FIRE DEPARTMENT
-575-4407
Project: (..,02
Type of Inspection: ca t
Fire Alarm:
Address: ,, f 4 tit -0 f k,
Suite#:� t�J"Tu 5. 5'r—
Contact Person:tre:--1)
Special Instructions:
Phone No.:
'pproved per applicable codes.
Corrections required prior to approval.
COMMENTS:
4 pI v& 59,r D'v,,s St
„Spcr11f/-�,-
11 ce/v6-14--- 1-ee-71-0 efr° PL— MS
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector: f5i'7 _
o.te:0/1¢
Hrs.: I
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. CaII to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word/Inspection Record Form.Doc
3/14/14
T.F.D. Form F.P. 113
6/0 NB/
SHOWER
8'-1
W.I.G.
5'-9"
2'-3"
-1D
r1, BEDROOM -2
3-
OD
n
10'. 1"
7'-0 1/2"
TSNONE
ALARM
41-911
Ln
M
83M0HS
/era 0/S
4-10--
W.I.C.
(4)._Ngo
C4
5'-3 1/2"
22'x29'
ATTC
ACCESS
10'1 6"
1Q21-
BEDROOM -3
W.I.C.
4'-5" 4'-5"
SHOWER
75MOKE
ALARM
5'-3"
5'-10 1/2"
10'-7 1/2"
4'-6"
DECK
7'-5"
'LIKWILA FIRE DEPARTMENT
Il
east,... ea.. call 206-575-4407 and
Ji 4G this Fire Permit No.
I Li c0
': id exact addles for shut
-:.:u vrt or resinratIon approval.
/8' -1-O' OOR SPRINKLER PIPING PLAN
1
® Without Comments
VC As Noted in Red
0 Per The Attached Letter
These plans have been reviewed by The Tukwila Fire
Prevention Bureau'for conformance with current City
standards. Acceptance is subject to errors and
omissions which do authorize violations of adopted
standards'and Orton -TTS c , :. The responsibility for the
adequacy of desigi ;totally with the designer.
Additions, drAetions revisions to these drawings after
this date will vold trt:,c.eptance and will require a
resubmittal of /wisec drawinQs for subsequent approval.
Final acceptance i subject tic field test and Inspection by
The Tukwila Fire Prevention Bureau.
Date: 7/D-7- / 3 By;
l�Ydw rett,;irt-A
r (ow (b.o144-i- ret„; re.A •
BLAZEMASTER® PIPE DIMENSIONS
SDR 13.5 (ASTM F442)
INCHES (MILLIMETERS)
NOMINAL SIZE
AVERAGE OD
AVERAGE ID
POUNDS/FT.
3/4" (20.0)
1.050 (26.7)
.874 (22.2)
.168
1" (25.0)
1.315 (33.4)
1.101 (28.0)
.262
134" (32.0)
1.660 (42.2)
1.394 (35.4)
.418
136" (40.0)
1.900 (48.3)
1.598 (40.6)
.548
2" (50.0)
2.375 (60.3)
2.003 (50.9)
.859
2134" (65.0)
2.875 (73.0)
2.423 (61.5)
1.257
3" (80.0)
3.500 (88.9)
2.951 (75.0)
1.867
R-11 BAT MINIMUM
SECURE INSULATION TO JOIST
INSULATION TO SHEETROCK LEVEL -
CUT INSULATION TO PUSH DOWN BETWEEN JOIST
TENTING DETAIL C
N
S
' 10' 12' 14' 16 18'
INSULATION TO SHEETROCK LEVEL
1/2" SHEETROCK
NOTES
SECURE INSULATION TO JOIST
R-11 BAT MINIMUM
71-511
15'-5"
7'-9"
5
FAM
LY ROOM
e4
5'-10 1/2"
5'-1 1/2"
n141
WASHER
6
2
14 112 - 3-0 2-3
BEAM
8'-2" 8'-0"
INGRESS &
EGRESS WINDOW
M X�
16'x24' PP
CRAWL SP.
ACCESS
21-511 21-311
SMOKE ALARM &
CARBON MONOXIDE
(C0) ALARM
-7 /
ISLAND \
ub
KITCHEN
I
- M
36' MINIMUM
MNDRAILS TIP.
10-9
AWE
ALARM
5/0 106/
SHOWER
t
, 011
4-10
5
SIA OKE ALJ�jjY 8�j'
CARBON M DXIf F)�
(C0) ALAR
O
0
M
1-712
2-11,„
D.
3'-7 1/2"
FU
N
FAN
LAUNDRY
7)
11
4-9
4'-10 1/2"
J
s
OICE
ALARM
As
OPEN TO
ABOVE
ENTRY/FOYER
T.J.I. JOISTS
DINING
9' aim
UNE
5'-8 1/2"
F FLOOR ABM
8'-3 1/2"
LIVING
OPEN TO
ABOVE
1 1/2"
6'-2 1/2"
CO
1n
4-10
T.J.I. JOISTS
FIRE SP
5-8
GARAGE
4-10
5'_3"
5-8
10'-6"
7-9
51-311
INKLER RISER LOCATION
;a4l;IAAA1101
11' DRYwAu
1) MAIN FLOOR SPRINKLER PIPING PLAN
6" ELECTRIC BELL "
WIRING AND CONDUIT BY OTHERS
INSULATION DOWN TO SHEETROCK LEVEL
TENTING DETAIL A
R-11 BAT MINIMUM
TENTING DETAIL B
2" AT11C JOIST
INSULATION TO SHEETROCK LEVEL
2" ATTIC JOIST
ri---
REVISIONS
2'xe' BOTI011
TREATED PLATE
NOTE:
TRUSS LAYOUT WILL BE PROVIDED
TO THE PLAN EXAMINER 7 DAYS
IN ADVANCE BEFORE INSTALLATION
FOR APPROVAL, DESIGNED BY
TRUSS 00. ENG.
(82E DEIFRYNED BY
OPERNC WUTN)
SKIDS 2X4 012'0.a
TABLE 1
MAXIMUM SUPPORT SPACING DISTANCE
END UNE SPRINKLER HEAD DROP ELBOW
0
0
JYP. FLOOR CCESIRUCTON]
> 100 psi
3/4"
9"
3/4' TMC PLYIOO9
1"
12"
9"
W
LJOISTS
16"
12"
_
CROSS X40J.L OR
12"
4.9
,;y
CRAS PER FLOOR LYS(?!
RELIABLE
RC 49
2"
1
BY OIIERS
TABLE 1
MAXIMUM SUPPORT SPACING DISTANCE
END UNE SPRINKLER HEAD DROP ELBOW
PIPE SIZE
inches
SYSTEM PRESSURE
< 100 psi
> 100 psi
3/4"
9"
6"
1"
12"
9"
114"
16"
12"
134"-3"
24"
12"
TABLE 2
MAXIMUM SUPPORT SPACING DISTANCE
INLINE SPRINKLER HEAD DROP TEE
PIPE SIZE
inches
SYSTEM PRESSURE
< 100 psi
> 100 psi
3/4"
4'
3'
1"
5'
4'
1134"
6'
5'
134"-3"
7'
7'
SECURE AGAINST
UPWARD MOVEMENT
GENERAL NOTES
1. System to be designed to N.F.P.A. #13D, 2007 edition and Fire Department requirements.
2. System hydraulically calculated to Fire Departments requirements and to N.F.P.A. 13D and Manufacturers Requirements.
3. Minimum pipe size to be 1" throughout job.
4. System to be hung per manufacturers requirements. Avcon Hangers to be used - Fig 511 & no block & head set.
5. All underground piping to conform to local Water Department requirements. This is for fill line only
6. Water information to be provided by pump manufacturer. Source of water by owner.
7. Transition from underground to riser to be copper type K typical unless noted otherwise
8. Risers that are exposed should be to be steel, cpvc is exceptable. Risers that rise up in wall to have typical access panel,
provision of this panel to be per contract.
9. All electrical wiring and conduit for electrical switches to be by others.
10. Cleaning and painting of pipe to be by others, if required.
11. All drilling and notching to be per manufacturers specifications and Fire Department requirements.
12. All piping to be CPVC typical unless otherwise noted.
13. Items to be verified at time of inspection:
a) Pressure at base of riser
b) Sprinkler head location and spacing.
c) Heads located from heat zones
d) Exposed piping should be steel.
e) Sprinkler heads in unconditioned areas to be 175° degrees
14. Alarm bells to be located per Fire Department requirements.
15. Testing of system to be per N.F.P.A. #13D and Fire Department Requirements.
16. Sprinklers may be omitted from closets less than 3'0" in depth or not over 24 sq. ft.
ASTM F442 CPVC
BRANCHLINE
FLOOR
CEILING
FLOOR
FLOOR JOISTS
FIRE SPRINKLER
*NSF INTERNATIONAL APPROVED FOR USE WITH POTABLE WATER
SECURE AGAINST
UPWARD MOVEMENT
ASTM F44�2 CPVC
BRANCHLINE
.11.
171
CEILING
COW,
MINK
13101040 PAPER.
aRDGE 5061440"
DP. EXT. WALL CO SIROCOON:
[101101-411ANIC 81)1140
BUILDING MAP
I{j 058 SNEATI 649
288' STUDS 016 0,a
1221 BATT N8AA1101
Ji CYPSUY BOARD
1" CPVC ADAPTER
1" CPVC
1" STEEL PIPE
1" STEEL PIPE
1" STEEL PIPE
1" BACKFLOW DEVICE
AMES
1" COPPER ADAPTER
Finish Floor
10' x %" ANCICR BOLTS
2' DEMENT
0 411' SPA0110
81)60( 00(40. WALL
DRAIN TRE
4• CONCRETE SLAB W114 6 LA. VAPOR BARRIER
01/02 4' COMPACT SVD AEAGRANEL BASE
BUILDING SECTION A -
1/8' - 1'-O'
1" GALV STEEL 90°
WIRING AND CONDUIT
AND INSTALLATION
TO BE BY OTHERS
CENTRAL
RISER NIANIFp LDST/:
11 DRAItEJJ v TC7
231 PRESS RE GAUGE
4SIGNS ON BODY
DRAIN
NORCO FIRE PROTECTION
POINT OF CONNECTION
DRAIN TO DISCHARGE
OUTSIDE OF BUILDING
1" COPPER LINE
FLOOR
--A
CPVC DROP = 0.329
FIRE SPRINKLER
CPVC DROP
FIRE SPRINKLER
RISER DETAIL
scale 1/2"=10"
MAXIMUM SPACING OF HEADS TO BE 18 X 18 AND 9' OFF WALL IN SINGLE HEAD ROOM
MAXIMUM SPACING OF HEADS TO BE 16 X 16 AND 8' OFF WALL IN MULTIPULE HEAD ROOM
SPRINKLER SYMBOLS
SYMBOLS
® SYSTEMS RISER
o RISE UP
• DROP DN
4-7 2 WAY EARTHQUAKE BRACE
4 WAY EARTHQUAKE BRACE
® GROOVED COUPLING
\301 HANGER TYPE AND LOCATIO
Q UPRIGHT HEAD
®e PENDENT HEAD
D SIDE WALL HEAD
LEGEND
OA UPRIGHT OVER PENDENT
25 PIPE SIZING
1 HYDRAULIC CALC NODE
REVISION NUMBER
Q BRANCH LINE NUMBER
11 -AT> WELD TAG NUMBER
DATE
DESCRIPTION
BY
SYM
CNT
NAME
METAL
TEMP
K
NPT
ORIF
MFG.
MODEL#
ESCUT
CONN.
1,
31
CONCEALED
WHITE
160
4.9
1/2"
7/16
RELIABLE
RC 49
2"
Defaul
iI
4
DRY PEND
WHITE
160
5.6
1"
1/2
RELIABLE
F3QR
ELBOW 45'
Defaul
35 TOTAL HEADS ON THIS PROJECT
TVP. 00RR. WALL
2-274' TOP PLATE, 2'X4' SILOS IIi6 aG
R-21 MN. NSA. 274' MLR. BOTTOM PLATE
W/ 1/2-3 A8. PER SRL SRL 1/2' 01111 NM TVP.
FIMSF4 TD .as
-ERMBNO
-INSULATION
-VAPOUR ARRER
-DRYWALL
FUMED GRADE
FLOOR JOISTS
FIRE SPRINKLER
*NSF INTERNATIONAL APPROVED FOR USE WITH POTABLE WATER
7! R5 OR BETTER SPRAY CR
4 MGM
CONT.
liSUL RENON
MUDS
Note:
Section notes by P. Eng. shall
have precedence over designer's
STEEL PIPE
BLAZEMASTE1' CPVC
\--FEMALE ADAPTER
A2, (D -8")+B t D 30"
A: (D-203mm)+8 D 762mm
SOFFIT FORMULA
PIPE HANGER
(CLOSE TO TEE)
X
CEIUNG
CURE TIMES WITH ONE S9P'SOLVENT CEMENT
200 psi (MAXIMUM) TEST PRESSURE
PIPE SIZE
inches
Ambient Temperature During Cure Period
60'F to 120'F
40'F to 59'F
O'F to 39'F
3/4"
45 min.
1.5 hr.
24 hr.
1"
45 min.
1.5 hr.
24 hr.
114"
1.5 hr.
16 hr.
120 hr.
134"
1.5 hr.
16 hr.
120 hr.
2"
8 hr.
36 hr.
See Note 1
234"
8 hr.
72 hr.
See Note 1
3"
8 hr.
72 hr.
See Note 1
Note 1 For these sizes, the solvent cement can be applied at temperatures
below 32'F, however, the sprinkler system temperature must be raised to
a temperature of 32'F or above and allowed to cure per the above
recommendations prior to pressure testing.
ALLOWANCE FOR FRICTION LOSS IN CPVC FITTINGS
(EXPRESSED IN EQUIVALENT FEET OF PIPE)
FITTING
PIPE DIAMETER
3/4"
1"
1 %"
11",
2"
234"
3"
TEE BRANCH
3
5
6
8
10
12
15
TEE RUN
1
1
1
1
1
2
2
ELBOW 90'
7
7
8
9
11
12
13
ELBOW 45'
1
1
2
2
2
3
4
COUPLING
1
1
1
1
1
2
2
FIRE SPRINKLER
ASTM F442 CPVC
BRANCHUNE*
X \
WOOD JOISTS
* NSF INTERNATIONAL APPROVED FOR USE WITH POTABLE WATER
AFCON 511 C.P.V.C.
PIPE HANGER SIDE MOUNT
MATERIAL: CARBON STEEL
APPROVALS: UL AND CUL LISTED.
FINISH: MIL. GALVANIZED, G-90 GOVERNMENT SPEC.
C.P.V.0
PIPE
SIZE
A
B
C
MAX.
HANGER
SPACING
(FT)
3/4"
3 1/8"
19/16
13/16
51/2
1"
33/8"
111/16
13/16
6
11/4"
43/16"
23/32
13/16
61/2
1 1/2"
4 7/16'
2 7/32
13/16
7
2"
4 7/8"
2 7/16
1 3/16
8
o (
O (
) O
) O
SHB1 HEADSET HANGER
BLAZEMASTER® PIPE
SDR 13.5 (ASTM F442)
HANGER SPACING
NOMINAL SIZE
MAX SPACING
inches
(mm)
feet
(m)
3/4"
(20.0)
5.5'
(1.7)
1"
(25.0)
6.0'
(1.8)
114"
(32.0)
6.5'
(2.0)
13"
(40.0)
7.0'
(2.1)
2"
(50.0)
8.0'
(2.4)
234"
(65.0)
9.0'
(2.7)
3"
(80.0)
10.0'
(3.0)
OWNER INFORMATION
NAME
RSVP REAL ESTATE, INC.
ADDRESS
10900 NE 8TH ST, STE 1000
BELLEVUE, WA
PHONE
206-244-1900
FIRE DEPT INFORMATION
NAME
TUKWILA FIRE DEPT
ADDRESS
444 ANDOVER PAARK EAST
TUKWILA, WA 98188
PHONE
425-481-8827
WATER DEPT. INFORMATION
NAME
ADDRESS
PHONE
WATER INFORMATON
STATIC
75
RESIDUAL
20
GPM
4856
MAIN SIZE
8"
SOURCE
AS BUILT DRAWING
TUKWILLA WATER DEPT
BUILDING INFORMATION
SQ. FT.
5063 SQ.FT.
TYPE
Wood Frame
OCCUPANCY
Residential
LEGAL DESCRIPTION
TAX PARCEL ID# 0040000681
CURE TIMES WITH ONE STEP SOLVENT CEMENT
200 psi (MAXIMUM) TEST PRESSURE
PIPE SIZE
inches
Ambient Temperature During Cure Period
60'F to 120'F
40T to 59'F
0'F to 39'F
3/4"
45 min.
1.5 hr.
24 hr.
1"
45 min.
1.5 hr.
24 hr.
134"
1.5 hr.
16 hr.
120 hr.
134"
1.5 hr.
16 hr.
120 hr.
2"
8 hr.
36 hr.
See Note 1
234"
8 hr.
72 hr.
See Note 1
3"
8 hr.
72 hr.
See Note 1
Note 1
For these sizes, the solvent cement can be applied at temperatures
below 32'F, however, the sprinkler system temperature must be raised to
a temperature of 32'F or above and allowed to cure per the above
recommendations prior to pressure testing.
PERMISSIBLE BENDING DEFLECTIONS SDR 13.5 (73T)
(ONE END RESTRAINED)
PIPE SIZE
inches
LENGTH OF RUN (L�) IN FEET
2'
5'
7'
10'
12
15'
17'
20'
3/4"
1.3"
7.8"
15.4"
31.3"
45.1"
70.5"
90.6"
125.4"
1"
1.0"
6.3"
12.3"
25.0"
36.0"
56.3"
72.3"
100.1"
1Y4"
0.8"
5.0"
9.7"
19.8"
28.5"
44.6"
57.3"
79.3"
1'34"
0.7"
4.3"
8.5"
17.3"
24.9"
39.0"
50.1"
69.3"
2"
0.6"
3.5"
6.8"
13.9"
20.0"
31.2"
40.0"
55.4"
21/4"
0.5"
2.9"
5.6"
11.4"
16.5"
25.8"
33.1"
45.8"
3"
0.4"
2.4"
4.6"
9.4"
13.5"
21.2"
27.2"
37.6"
BACKFLOW ASSEMBLY REQUIRED IS PER STATE PLUMBING CODE
BACKFLOW ASSEMBLY IS REQUIRED BY WATER DEPARTMET
NOT FIRE DEPARTMENT AND IS PART OF THE POTABLE WATER SYSTEM
PERMITING AND INSTALLATION AND TESTING TO BE DONE BY OTHERS
ORCO
Fire Protection, Inc.
PO Box 363
Ravensdale, WA 98051
425-432-7250
L2
D
L/)
4640 S '148th
FLOOR AREA:
TOTAL LOT AREA=11,730 SQ.FT.
VICINITY MAP w-110
TOTAL MAIN FLOOR AREA=2092 SQ.FT.
NET TOP FLOOR AREA=2277 SQ.FT.
TOTAL FLOOR AREA=4369 SQ.FT.
N
E
\,
s
WASHINGTON STATE L- 0
CERTIFICATE OF COMPETENCY a
FIRE PROTECTION SPRINKLER SYSTEL$S
Edwin P. Cogar • .
4295 -0499 -CG Level 3 1
Norco Fire Pr" ectioA inc. ••
NORCOFP_«'` •' 1
Signature
SIDHU HOMES LOT 2
4640 148TH ST
TUKWILLA, WA 98178
CONTRACTOR: NORCO FIRE PROTETION, INC.
0
OOOOOOOOOMIibO%
1.
1
1
PAID
JUN 25 2018
TUKWILA FIRE
4k -21/e2 �S�
PIPING PLAN
AREA 1
PERMIT NO.
CONTRACT NO.
N18061
APPROVAL
TUKWILLA FIRE
DRAWN BY
ED COGAR
SCALE
1/8" = 1'-0"
DATE
7/14/18
REVISED
PLOTTED
FP1of1