HomeMy WebLinkAboutPP - 4013 S 148TH ST - UNKNOWN - PERMITS AND PLANS4013 S 148TH ST ASSOCIATED PERMITS 06-S-039 WATER FLOW INFORMATION - STATIC: 75 PSI RESIDUAL: 20 PSI FLOW 4 20 PSI:4000 GPM HYDRANT TEST ELEVATION: XXX FT. FLOW AVAILABLE ® 20 PSI, XXX GPM PITOT READING: XXX TEST DATE: XXX TEST LOCATION: XXX WATER DEPARTMENT JURISDICTION: XXX 13'-O° BLIDa LN. 4S'/. 4O' -0„ ' -0" 11 O" lMii\1 30" AND l;\.�r , g40 EFVTO$ 100 CFM • 1' 1, 6-101/2�_._" 1' 1" 'tom,L 1 2-2 1 , Ir3t-L�G . LN, 4''. ii .OPEN TO ABOVE \v 1' 4-01k1 (13 11 iv.r q Ir. t SWING JOINT .,,,...____..„v,,,:..,..,.......,. _. r :\7 1 i.-� , N.-- SWING DN. `:.✓'� 'i- tc` M 1' 01' 1-4 9-9 • ti Cie i LIVING Roc ('EEE. ELEV.) i.LEA 1` 1 C- T HANGER LEGEND ,z 1, _.rL2 1 zzj F4i i I L.K " ROOM 1' 11' 3-31/2 1-2 U (0 fi 1' 8-4 5'-3" 1' co L i!. o I1,1-4W1-4)Lfl _ _._._.__. CacAi- INSTALL A SIDEWAIL OVER THE RISER I �mm eFiRIN<LEIS A1, E NOI REQUIIREE) FER NFF4 1310 cr1 W45t4 _kl vT05 1 14 FIRE -SPRINKLER RISER LOCATION SEE RISER DET, if I: 7 r z../.,?i. rz.l_ Main Floor Plan I/4'1=11..00 PROPERTY UNE South 148 Street STANDARD SYMBOLS TO PUBLIC MAIN 11/2 " COFFER O1R CFVC FIFE SPRINKLER HEAD SYMBOLS 1" WATER METER 1" COPPER SPRINKLERS RELIABLE RESIDENTIAL RELIABLE RESIDENTIAL • RFC43 1 RES49 x x 4,3 4,9 BRASS WHITE WHITE • WHITE CONC. REC. 155' 75° SPARE HEAD CABINET W/ HEADS & WRENCH gf 90 ELBOW TO SYSTEM 1.5" CENTRAL MODEL 130 "" RISER MANIFOLD W/: (1) DRAIN AND TEST (0(2) FLOW SWITCH Ir'irri_� (3) PRESSURE GAUGE tt� (4) SIGNS ON BODY 10" ELEC. ALARM BELL tit -- 11/2' AYES MODEL 2000B • DOUBLE CHECK VALVE NOR -TECH WORK BEGINS TO DOESTIC F*..USH OUTLET 11/4' FEM. THRD, ADAPT, FINISH FLOOR SUPPLY Riser Detail GENERAL NO 1 . THIS ``SYSTEM IS DESIGNED PER SPRINKLER MANUFACTURER'S LISTING. SEE ATTACHED CUT SHEETS FOR MANUFACTURER'S MIN. REQUIREMENTS. A TOTAL OF (2) HEADS OPERATING USING RESIDENTIAL, CONCEALED. 2 . INSTALLATION TO CONFORM WITH NFPA #13D & TUKWILA FIRE DEPT. 3 . ALL MATERIAL TO BE NEW, U.L. LISTED, AND PER NFPA 1.3. 4 . ALL FITTINGS TO BE CPVC U.N.O. 5 . ALL PIPE TO BE CPVC U.N.O. 6 . PROTECTION OF HEADS FROM PAINT BY OTHERS. 7 ALL ELECTRICAL WIRING BY OTHERS. MK DATE BY REVISIONS — LOCATE BY GRID COORDINATES FIELD INSPECTION BY 1. TUKWILA FIRE DEPT. PHONE 206-575-4404 Composite Wood Joist ti DVC NB -1 Headset Mounting Bracket and No Block Hanger - Offset Hanger Headset .. Gyp. Board Ceiling A\G-1? D -TAIL "A" NB -2 Headset Mounting Bracket and No Block Hanger Offset Hanger c�vc HAS G -k' U FHFHGH Gyp. Board Ceiling "TAIL " 99 FILE ACCEPTED Without Comments • As Noted In Red 0 Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and of:dinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions o these drawings after this date will void thic,acceptance arid will require a resubmittal of revised drawings for.subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 3 -/-of- By: CONTRACT WITH RASHPAL SINGH 2. ADDRESS 24606 MILITARY RD. S. 3. CITY KENT, WA 98032 RESIDENTIAL x 4,9 WHITE WHITE HSW 175' TOTAL SPRINKLERS THIS DRAWING 13 4 PHONE XXX WATER DEPT. ADDRESS CITY PHONE ARCHITECT Crane Design Inc. ADDRESS 18000 72nd. Ave S. CITY Kent, WA 98032 PHONE 425-656-0559 NORTH SCALE: 1/4"=1 '-0" TUKWILA FIRE DEPARTMEiUL Please call: 575.4402 ..�' and give this job No. OD -S- 039 rnd exact address for shut. -,roam or restoration approval; PROJECT Singh Residence ADDRESS: 4013 S. 148 STREET CITY TUKWILLA, WA 98166 PARCEL # 0041-00-0167 TITLE: FIRE SPRINKLER PLAN NOR -TECH FIRE PROTE*WTI 20030 NE Novelty Hili Road—Box B REDMOND, WASHINGTON 98053 425-898-9111 FAX: 425-898-7772 LICENSE NO. NORTEFP051P6 CONTRACT #. 0106-083 • SHEET NO. FP -1 of 2. FEB 2 8 2006 Tukwila F're 12 .,3T I 2/25/2006 2:23:54 PM 40' — 0 10'-11° 5'-0° 101-4" MOST DEMANDING HEAD PER NFPA 13D AND PER MANUFACTURER'S LISTING. RELIABLE MODEL RFC43 CONCEALED HORIZ. FLAT CEIUNG MIN. FLOW AT 16'x16' SPACING; 13 GPM 5'-52� NB -1 Headset Mounting Bracket and No Block Hanger O D ROOM 3 .-- ROOV 2 I M4SyTE 5._0 ,. BD OOM — Offset Hanger Composite Wood Joist A' n_.' _ R : Ti = _. P" t P 8.6.1 SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT WHERE OMISSION IS PERMITTED BY 8.6.2 THROUGH 8.6,6 8.6.2 SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 S.F. OR LESS 8.6.3 SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES THAT MEET ALL OF THE FOLLOWING CONDITIONS. (1) THE AREA OF THE SPACE DOES NOT EXCEED 24 S.F. (2) THE LEAST DIMENSION DOES NOT EXCEED 3 FEET. (3) THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED MATERIALS AS DEFINED IN NFPA 220, STANDARD ON TYPES OF BUILDING CONSTRUCTION. 8.6.4* SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES, OPEN ATTACHED PORCHES, CARPORTS, AND SIMILAR STRUCTUTRES. 8.6.5 SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS, CRAWL SPACES, AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING PURPOSES. 8.6.6 SPRINKLERS SHALL NOT BE REQUIRED IN COVERED UNHEATED PROJECTIONS OF THE BUILDING AT ENTRANCE AS LONG AS THERE IS ANOTHER MEANS OF EGRESS FROM THE DWELLING UNIT. 6'-3" - Headset f, Gyp. Board Ceiling 1- N N r c�s 6 R45 Rt5 t R4S / 0, ././//,' � r. to C DVC HA G R LTA L 99 99 A1TIC INSULATION %T7i�stt?tt?t NB -2 Headset Mounting Bracket and No Block Hanger / in BEDROOM4 1° \.J 1' 3-6 6-6'/2 Aik Impr Wood Joist \ Offset Hanger FIRE SPRINKLER PIPE (ON WARM SIDE OF INSULATION). TRUSS AND GYPSUM WALL BOARD CEILING 'MSQUEEN" FHFHGH L)" I, Res Headset SPRINKLER PIPE IN THE ATTIC NO SCALE / l Gyp. Board Ceiling P(2)ER NEPA MOST D134 ANDG HEAD PER MANUFACTURER'S LISTING. RELIABLE MODEL- RFC43 CONCEALED BELOW HORIZ. FLAT CEILING MIN. FLOW AT 16'x16' SPACING; 13 GPM ® I10VSD / 1` 1" 3-6 FIAT CEILING BLDG. LN. I5ELOUJ 3 111 J C3VC AN G DLTA L 99 99 HYDRAULIC CALCULATIONS ARE BASED ON 16'x16' SPACING INSTALLED BELOW SMOOTH, FLAT HORIZONTAL CEILING 1CNU;,�p ROOT f • .ENERAL NNQTES: 20'-4 401 —0" '-11° WATER FLOW INFORMATIQN: STATIC: 75 PSI RESIDUAL: 20 PSI FLOW @ 20 PSI: 4000 GPM HYDRANT TEST ELEVATION: XXX FT. FLOW AVAILABLE @ 20 PSI, XXX GPM PITOT READING: XXX TEST DATE: XXX TEST LOCATION: XXX WATER DEPARTMENT JURISDICTION: XXX HANGER LEGEND STANDARD SYMBOLS SPRINKLER HEAD SYMBOLS SPRINKLERS RELIABLE RESIDENTIAL RELIABLE RESIDENTIAL SYMB. 40 O MODEL RFC43 c1 RES49 THREAD I1? 1/2e ORIFICE X X 43 4,9 FINISH BRASS WHITE ESCUTCH, WHITE WHITE TYPE CONC. REC. 155" 175' RESIDENTIAL 1 I'2 4,9 WHITE WHITE HSW 175' BY GRID COORDINATES 1 . THS SYSTEM IS DESIGNED PER SPRINKLER MANUFACTURER'S LISTING. SEE ATTACHED CUT SHEETS FOR MANUFACTURER'S MIN. REQUIREMENTS. A TOTAL OF (2) HEADS OPERATING USING RESIDENTIAL, CONCEALED. 2 . INSTALLATION TO CONFORM WITH NFPA #1 3D 8c TUKWILA FIRE DEPT. 3 . ALL MATERIAL TO BE NEW, U.L. LISTED, AND PER NFPA #13. 4 . ALL FITTINGS TO BE CPVC U.N.O. 5 . ALL PIPE TO BE CPVC U.N.O. 6 . PROTECTION OF HEADS FROM PAINT BY OTHERS. ? . ALL ELECTRICAL WIRING BY OTHERS. FIELD INSPECTION BY 1. XXX PHONE XXX CONTRACT WITH RASHPAL SINGH 2 3. 4. WATER DEPT. ADDRESS CITY ADDRESS 24606 MIUTARY RD. S. CITY KENT, WA 98032 PHONE 206-650-7100 ARCHITECT Crane Design Inc. ADDRESS 18000 72nd. Ave S. NORTH CITY Kent, WA 98032 TOTAL SPRINKLERS THIS DRAWING PHONE PHONE 425-656-0559 SCALE: PROJECT Singh Residence ADDRESS: 4013 S. 148 STREET CITY TUI<WILLA, WA 98166 TITLE: FIRE SPRINKLER PLAN PARCEL # 0041-00-0167 DATE: 2-8-06 NOR -TECH FIRE PROTECTION INC. 20030 NE Novelty Hill Road -Box B REDMOND, WASHINGTON 98053 425-898-9111 FAX: 425-898-7772 LICENSE NO. NORTEFP051P6 0106-083 • SHEET NO. I FP -2 Of 2 2/25/2006 2:17:27 PM