Loading...
HomeMy WebLinkAboutPP - 4050 S 146TH ST - UNKNOWN - PERMITS AND PLANS4050 S 146TH ST ASSOCIATED PERMITS 12-S-265 D12-277 4411t1"444 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: ..)U SU S I q (.0 PI St Tenant Name: Property Owner's Name: Mailing Address: King Co. Assessor's Tax No.: Date application accepted: PAID 0- 274334 DE41`2417 TUKWILA FIRE Suite Number: 1 V' y Floor: New Tenant? ❑ - Yes ❑ - No CONTACT PERSON -if there are questions about the submittal. City State Zip Name: TO h T N4N1i 1 Day Telephone: 3 / 7 1(3 ) (.1(1 p Company NamezSJi4 1&& Y1r(,d} nL4KV i 1. 1 C Mailing Address 7 % Vi. 2041.4/ SA- kj fr l n 4Un 7�1 99.,Z.-5 Q 1 E-mail Address: `114rikjr etqi'-V���.(6vFax Number:31,(o!JSjteQ?Ell (.0 Valuation of Project (contractor's bid price): $ t AiwicE,1 Scope of Work (please provide detailed information): _ ,� ink Fe !IL) $' , r rm PERMIT APPLICATION NOTES Value of Construction — In al! cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: Print Name: Day Telephone: Plan Permit App.doc 5/14/10 TFD FP Form 8 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: 1'L SN��\.M� Type of Insp iQn: _c, Address: ti 051)S)(415.4.-4--- Suite #: Contact Person: Special Instructions: Phone No.: ..Approved per applicable codes. Corrections required prior to approval. COMMENTS: S 1/4 "L 0� Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Date: 64;,// ? Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 1 T.F.D. Form F.P. 113 7- INSPEC11ON NUMBER INSPECTION RECORD Retain a copy with mt i �-- S — o2�s Dig—c7? PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: 71 _-N Li tfjk-M-t. Sprinklers: T e,Qof Inspection: 1 . Iv,ArL- Address: uose,S Suite #: ty G Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: S P S',JNL - dK Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: 5--z..., Date: Low 2 Hrs.: i $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /1— 5- a&s-- vii PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 N6-575-4407 Project: o- 1 Ai u ,e5f Adv.edks Type of Ins ection: frd Ektied / edii-et-- Audress:/ ib S-° Suite #: `7 S 1146 Contact rson: Special Instructions: Permits: Phone No.: yl -Approved per applicable codes. nCorrections required prior to approval. COMMENTS: OK F`rw‘ SL C") --r Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: A s" --,X._ Date: 7 hg /, 3 Hrs.:01, ,rr.v„‘, n $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 A-Pex Design Services, Inc. -EP 10731 47th PI W Mukilteo, WA 98275 425-493-9680 Job Name : TL INVESTMENT GROUP LOT 4 - Two Head Calculation (H.11 & H.12) Drawing Location : 4050 S 146TH STREET TUKWILLA WA 98168 Remote Area : Contract : 121119-01 Data File : 121119-01 TL Investment Group Lot 4.wx2 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A-Pex Design Services, Inc. -EP Page 1 TL INVESTMENT GROUP LOT 4 - Two Head Calculation (H.11 & H.12) Date 11/19/2012 HYDRAULIC DESIGN INFORMATION SHEET Name - TL INVESTMENT GROUP LOT 4 Date - 11-19-12 Location - TUKWILLA WA 98168 Building - System No. - Contractor - SOUNDVIEW PLUMBING Contract No. - 121119-01 Calculated By - KAREN BABB Drawing No. - Construction: (X) Combustible ( ) Non -Combustible Ceiling Height OCCUPANCY - RESIDENTIAL S Y S T E Type of Calculation: ( )NFPA 13 Residential Number of Sprinklers Flowing: ( )1 (X)2 ( )Other ( )Specific Ruling ( )NFPA 13R ( )4 ( ) (X)NFPA 13D Made by Date M Listed Flow at Start Point - 13 Listed Pres. at Start Point - 9.14 Psi D MAXIMUM LISTED SPACING 16 x 16 E Domestic Flow Added - 0 S Additional Flow Added - I Elevation at Highest Outlet - 116 G Note: N Gpm Gpm Gpm Feet System Type (X) Wet ( ) Dry ( ) Deluge ( ) PreAction Sprinkler or Nozzle Make RELIABLE Model RFC43 Size 3/8 K -Factor 4.3 Temperature Rating 155 Calculation Gpm Required 26.0024 Psi Required 61.22 Summary C -Factor Used: Overhead 150 At Ref Pt STR Underground 150 W Water Flow Test: A Date of Test T Time of Test - E Static (Psi) - 70 R Residual (Psi) - 65 Flow (Gpm) - 300 S Elevation - 100 Pump Data: Rated Cap. @ Psi Elev. Other Tank or Reservoir: Cap. Elev. Well Proof Flow Gpm P Location: P L Source of Information: Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) L w N N d0 - Two Head Calculation (H.11 & H.12) O w � Li d O a) CC _U 0 Z � � Z W c rnF U) • W 0> X • Z a_1 Q � Fittings Used Summary Two Head Calculation (H.11 & H.12) 0 N O v N 0 CO O O M N a) E c Z J • 0) .0 LL < r M N O 0 0 0 �- 0 0 0 )00', - At 0) 0 0 0 0 A- V' CO CO 000 10 CO I- 1- 0 0 0 I� 0 N (0 (0 0 0 0 N 0 N O O 0 0 0 CO O ▪ ' CO 0 0 0 " 0 • M CO 0 0 0 N O N N 0 0 0 0 0 • (V N 0 0 0 O 0 0 O f�'A-000 N (0' 000 CO N i CO '- N N V Nr (n '-,-N N N A— CO CO N A— U C 3 > 3c a)(1) 21 w F- -0 ` W N a) co0w� HH co C 0 0. a. 0. O CLL 7 Si 7 O 0b 0' 0' 0' rn0rnaaa s Units Summary Flow Summary - NFPA 2007 A-Pex Design Services, Inc. -EP Page 4 TL INVESTMENT GROUP LOT 4 - Two Head Calculation (H.11 & H.12) Date 11/19/2012 SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure STR 70.0 65 300.0 69.946 26.0 61.217 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes H.12 116.0 T.36 116.0 H.17 116.0 H.20 116.0 T.43 116.0 T.41 116.0 T.42 108.0 H.18 108.0 T.39 108.0 H.14 108.0 H.6 108.0 T.28 108.0 T.29 108.0 S.1 104.0 MTR 100.0 STR 100.0 T.34 116.0 T.32 116.0 T.31 108.0 H.9 108.0 T.30 108.0 H.11 116.0 T.35 116.0 H.1 116.0 T.23 116.0 T.22 116.0 T.33 116.0 H.5 116.0 H.4 116.0 T.27 116.0 T.26 116.0 H.3 116.0 T.25 116.0 T.21 116.0 H.15 116.0 T.37 116.0 T.38 116.0 H.13 116.0 H.2 116.0 T.24 116.0 T.40 108.0 H.16 108.0 4.3 9.14 13.0 10.28 10.48 10.67 10.78 11.07 14.81 14.82 14.87 15.0 15.52 15.92 17.57 21.28 57.65 61.22 9.21 10.38 14.9 15.16 15.46 4.3 9.14 13.0 10.71 10.98 11.12 11.84 10.35 10.44 10.84 10.9 10.96 11.04 11.12 11.58 10.72 10.82 11.01 10.82 11.12 11.12 14.81 14.84 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - NFPA 2007 A-Pex Design Services, Inc. -EP Page 5 TL INVESTMENT GROUP LOT 4 - Two Head Calculation (H.11 & H.12) Date 11/19/2012 NODE ANALYSIS (cont.) Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes H.19 H.7 H.8 108.0 108.0 108.0 14.85 14.88 14.89 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A-Pex Design Services, Inc. -EP Page 6 TL INVESTMENT GROUP LOT 4 - Two Head Calculation (H.11 & H.12) Date 11/19/2012 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Notes ****** H.12 9.83 0.862 1 Utr 2.0 3.000 9.140 to 150.0 1 Utb 17.0 16.000 0.0 T.36 9.83 0.0602 0.0 19.000 1.144 K Factor = 4.30 Vel = 5.40 T.36 -4.76 0.862 1 Utr 2.0 9.000 10.284 to 150.0 0.0 2.000 0.0 H.17 5.07 0.0177 0.0 11.000 0.195 Vel = 2.79 H.17 0.0 0.862 1 Utr 2.0 9.000 10.479 to 150.0 0.0 2.000 0.0 H.20 5.07 0.0176 0.0 11.000 0.194 Vel = 2.79 H.20 0.0 0.862 0.0 6.000 10.673 to 150.0 0.0 0.0 0.0 T.43 5.07 0.0177 0.0 6.000 0.106 Vel = 2.79 T.43 -1.32 0.862 1 Uel 11.0 3.000 10.779 to 150.0 1 Utb 17.0 26.000 0.0 T.41 3.75 0.0101 0.0 29.000 0.294 Vel = 2.06 T.41 0.0 0.862 1 Utb 17.0 13.000 11.073 to 150.0 0.0 14.000 3.465 T.42 3.75 0.0101 0.0 27.000 0.273 Vel = 2.06 T.42 -1.07 0.862 0.0 2.000 14.811 to 150.0 0.0 0.0 0.0 H.18 2.68 0.0055 0.0 2.000 0.011 Vel = 1.47 H.18 0.0 0.862 1 Utr 2.0 6.000 14.822 to 150.0 0.0 2.000 0.0 T.39 2.68 0.0055 0.0 8.000 0.044 Vel = 1.47 T.39 3.70 0.862 1 Utr 2.0 3.000 14.866 to 150.0 0.0 2.000 0.0 H.14 6.38 0.0270 0.0 5.000 0.135 Vel = 3.51 H.14 0.0 0.862 1 Utr 2.0 17.000 15.001 to 150.0 0.0 2.000 0.0 H.6 6.38 0.0271 0.0 19.000 0.514 Vel = 3.51 H.6 0.0 0.862 1 Uel 11.0 3.000 15.515 to 150.0 0.0 12.000 0.0 T.28 6.38 0.0270 0.0 15.000 0.405 Vel = 3.51 T.28 5.95 0.862 1 Utr 2.0 2.000 15.920 to 150.0 1 Utb 17.0 16.000 0.0 T.29 12.33 0.0916 0.0 18.000 1.649 Vel = 6.78 T.29 13.67 1.054 1T 2.44 12.000 17.569 to 150.0 0.0 2.440 1.732 S.1 26.0 0.1368 0.0 14.440 1.975 Vel = 9.56 S.1 0.0 1.049 2E 6.044 170.000 21.276 to 150.0 0.0 6.044 11.732 MTR 26.0 0.1400 0.0 176.044 24.638 * Fixed loss = 10 Vel = 9.65 MTR 0.0 1.025 1E 2.7 12.000 57.646 to 150.0 1T 6.75 10.800 0.0 STR 26.0 0.1566 1G 1.35 22.800 3.571 Vel = 10.11 0.0 26.00 61.217 K Factor = 3.32 H.12 3.17 0.862 0.0 9.000 9.140 to 150.0 0.0 0.0 0.0 T.34 3.17 0.0074 0.0 9.000 0.067 Vel = 1.74 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A-Pex Design Services, Inc. -EP TL INVESTMENT GROUP LOT 4 - Two Head Calculation (H.11 & H.12) Page 7 Date 11/19/2012 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Notes ****** T.34 4.77 0.862 1 Uel 11.0 3.000 9.207 to 150.0 1 Utb 17.0 26.000 0.0 T.32 7.94 0.0405 0.0 29.000 1.175 Vel = 4.37 T.32 0.0 0.862 1 Utb 17.0 12.000 10.382 to 150.0 0.0 14.000 3.465 T.31 7.94 0.0405 0.0 26.000 1.053 Vel = 4.37 T.31 1.07 0.862 0.0 5.000 14.900 to 150.0 0.0 0.0 0.0 H.9 9.01 0.0512 0.0 5.000 0.256 Vel = 4.95 1-.9 0.0 0.862 1 Utr 2.0 4.000 15.156 to 150.0 0.0 2.000 0.0 T.30 9.01 0.0513 0.0 6.000 0.308 Vel = 4.95 T.30 4.66 0.862 1 Utb 17.0 3.000 15.464 to 150.0 1 Utr 2.0 16.000 0.0 T.29 13.67 0.1108 0.0 19.000 2.105 Vel = 7.52 0.0 13.67 17.569 K Factor = 3.26 T.34 -4.77 0.862 1 Utr 2.0 2.000 9.207 to 150.0 0.0 2.000 0.0 H.11 -4.77 -0.0158 0.0 4.000 -0.063 Vel = 2.62 H.11 13.01 0.862 1 Utb 17.0 22.000 9.144 to 150.0 0.0 14.000 0.0 T.35 8.24 0.0434 0.0 36.000 1.562 K Factor = 4.30 Vel = 4.53 T.35 -2.39 0.862 1 Utr 2.0 10.000 10.706 to 150.0 0.0 2.000 0.0 H.1 5.85 0.0230 0.0 12.000 0.276 Vel = 3.22 H.1 0.0 0.862 1 Utr 2.0 4.000 10.982 to 150.0 0.0 2.000 0.0 T.23 5.85 0.0232 0.0 6.000 0.139 Vel = 3.22 T.23 0.11 0.862 1 UeI 11.0 4.000 11.121 to 150.0 1 Utb 17.0 26.000 0.0 T.22 5.96 0.0238 0.0 30.000 0.715 Vel = 3.28 T.22 0.0 0.862 1 Utb 17.0 12.000 11.836 to 150.0 0.0 14.000 3.465 T.28 5.96 0.0238 0.0 26.000 0.619 Vel = 3.28 0.0 5.96 15.920 K Factor = 1.49 T.36 4.77 0.862 1 Utr 2.0 2.000 10.284 to 150.0 0.0 2.000 0.0 T.33 4.77 0.0160 0.0 4.000 0.064 Vel = 2.62 T.33 0.0 0.862 1 Utr 2.0 4.000 10.348 to 150.0 0.0 2.000 0.0 H.5 4.77 0.0157 0.0 6.000 0.094 Vel = 2.62 H.5 0.0 0.862 1 UeI 11.0 13.000 10.442 to 150.0 0.0 12.000 0.0 H.4 4.77 0.0158 0.0 25.000 0.395 Vel = 2.62 H.4 0.0 0.862 1 Utr 2.0 2.000 10.837 to 150.0 0.0 2.000 0.0 T.27 4.77 0.0158 0.0 4.000 0.063 Vel = 2.62 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A-Pex Design Services, Inc. -EP Page 8 TL INVESTMENT GROUP LOT 4 - Two Head Calculation (H.11 & H.12) Date 11/19/2012 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Notes ****** T.27 0.0 0.862 1 Utr 2.0 2.000 10.900 to 150.0 0.0 2.000 0.0 T.26 4.77 0.0158 0.0 4.000 0.063 Vel = 2.62 T.26 0.0 0.862 0.0 5.000 10.963 to 150.0 0.0 0.0 0.0 H.3 4.77 0.0158 0.0 5.000 0.079 Vel = 2.62 H.3 0.0 0.862 1 Utr 2.0 3.000 11.042 to 150.0 0.0 2.000 0.0 T.25 4.77 0.0158 0.0 5.000 0.079 Vel = 2.62 T.25 -0.11 0.862 1 Uel 11.0 4.000 11.121 to 150.0 1 Utb 17.0 26.000 0.0 T.21 4.66 0.0151 0.0 30.000 0.454 Vel = 2.56 T.21 0.0 0.862 1 Utb 17.0 14.000 11.575 to 150.0 0.0 14.000 3.465 T.30 4.66 0.0151 0.0 28.000 0.424 Vel = 2.56 0.0 4.66 15.464 K Factor = 1.19 T.35 2.38 0.862 0.0 3.000 10.706 to 150.0 0.0 0.0 0.0 H.15 2.38 0.0043 0.0 3.000 0.013 Vel = 1.31 H.15 0.0 0.862 1 UeI 11.0 11.000 10.719 to 150.0 0.0 12.000 0.0 T.37 2.38 0.0044 0.0 23.000 0.101 Vel = 1.31 T.37 1.32 0.862 1 Utb 17.0 5.000 10.820 to 150.0 0.0 14.000 0.0 T.38 3.7 0.0098 0.0 19.000 0.187 Vel = 2.03 T.38 0.0 0.862 1 UeI 11.0 14.000 11.007 to 150.0 1 Utb 17.0 26.000 3.465 T.39 3.7 0.0099 0.0 40.000 0.394 Vel = 2.03 0.0 3.70 14.866 K Factor = 0.96 T.43 1.31 0.862 1 Utr 2.0 23.000 10.779 to 150.0 0.0 2.000 0.0 H.13 1.31 0.0014 0.0 25.000 0.036 Vel = 0.72 H.13 0.0 0.862 1 Utr 2.0 1.000 10.815 to 150.0 0.0 2.000 0.0 T.37 1.31 0.0017 0.0 3.000 0.005 Vel = 0.72 0.0 1.31 10.820 K Factor = 0.40 T.25 0.10 0.862 1 Utr 2.0 3.000 11.121 to 150.0 0.0 2.000 0.0 H.2 0.1 0.0 0.0 5.000 0.0 Vel = 0.05 H.2 0.0 0.862 0.0 4.000 11.121 to 150.0 0.0 0.0 0.0 T.24 0.1 0.0 0.0 4.000 0.0 Vel = 0.05 T.24 0.0 0.862 1 Utr 2.0 4.000 11.121 to 150.0 0.0 2.000 0.0 T.23 0.1 0.0 0.0 6.000 0.0 Vel = 0.05 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A-Pex Design Services, Inc. -EP Page 9 TL INVESTMENT GROUP LOT 4 - Two Head Calculation (H.11 & H.12) Date 11/19/2012 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Notes ****** 0.0 0.10 11.121 K Factor = 0.03 T.42 1.07 0.862 1 Utr 2.0 1.000 14.811 to 150.0 0.0 2.000 0.0 T.40 1.07 0.0010 0.0 3.000 0.003 Vel = 0.59 T.40 0.0 0.862 1 UeI 11.0 15.000 14.814 to 150.0 1 Utr 2.0 14.000 0.0 H.16 1.07 0.0010 0.0 29.000 0.029 Vel = 0.59 H.16 0.0 0.862 0.0 10.000 14.843 to 150.0 0.0 0.0 0.0 H.19 1.07 0.0010 0.0 10.000 0.010 Vel = 0.59 H.19 0.0 0.862 1 UeI 11.0 17.000 14.853 to 150.0 0.0 12.000 0.0 H.7 1.07 0.0010 0.0 29.000 0.029 Vel = 0.59 H.7 0.0 0.862 1 Utr 2.0 9.000 14.882 to 150.0 0.0 2.000 0.0 H.8 1.07 0.0010 0.0 11.000 0.011 Vel = 0.59 1i.8 0.0 0.862 1 Utr 2.0 5.000 14.893 to 150.0 0.0 2.000 0.0 T.31 1.07 0.0010 0.0 7.000 0.007 Vel = 0.59 0.0 1.07 14.900 K Factor = 0.28 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 N �! c r k Stephanie-0Marie2130Fahey A-Pex Design Services, Inc. -EP 10731 47th PI W Mukilteo, WA 98275 425-493-9680 f' `H c,7 ° eCt/on SPy� nAk Job Name : TL INVESTMENT GROUP LOT 4 - One Head Calculation (H.5) Drawing Location : 4050 S 146TH STREET TUKWILLA WA 98168 Remote Area : Contract : 121119-01 Data File : 121119-01 TL Investment Group Lot 4.wx1 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 ' A-Pex Design Services, Inc. -EP Page 1 TL INVESTMENT GROUP LOT 4 - One Head Calculation (H.5) Date 11/19/2012 HYDRAULIC DESIGN INFORMATION SHEET Name - TL INVESTMENT GROUP LOT 4 Date - 11-19-12 Location - TUKWILLA WA 98168 Building - System No. - Contractor - SOUNDVIEW PLUMBING Contract No. - 121119-01 Calculated By - KAREN BABB Drawing No. - Construction: (X) Combustible ( ) Non -Combustible Ceiling Height OCCUPANCY - RESIDENTIAL S Y S T E Type of Calculation: ( )NFPA 13 Residential Number of Sprinklers Flowing: (X)1 ( )2 ( )Other ( )Specific Ruling ( )NFPA 13R ( )4 ( ) (X)NFPA 13D Made by Date M Listed Flow at Start Point - 18 Gpm Listed Pres. at Start Point - 17.52Psi D MAXIMUM LISTED SPACING 18 x 18 E Domestic Flow Added - 0 Gpm S Additional Flow Added - Gpm I Elevation at Highest Outlet - 116 Feet G Note: N System Type (X) Wet ( ) Dry ( ) Deluge ( ) PreAction Sprinkler or Nozzle Make RELIABLE Model RFC43 Size 3/8 K -Factor 4.3 Temperature Rating 155 Calculation Gpm Required 18 Summary C -Factor Used: Psi Required 52.84 At Ref Pt STR Overhead 150 Underground 150 W Water Flow Test: A Date of Test - T Time of Test - E Static (Psi) - 70 R Residual (Psi) - 65 Flow (Gpm) - 300 S Elevation - 100 P P L Y Pump Data: Rated Cap. @ Psi Elev. Other Tank or Reservoir: Cap. Elev. Well Proof Flow Gpm Location: Source of Information: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) One Head Calculation (H.5) nr w0 ' J ca �O U ct a) I— (I) Z c 0) aa)) 0) o> Z d J < 1- D3 - System Demand : 17.998 Safety Margin : 17.134 I.0 50 100 150 200 250 300 350 400 450 FLOW (NA1.85) •N 0 . a) • • v CNI c o- 0 0 0 0 0 0 Nr M N ' 0 0 0 O 0 0 O 0 (0 O 0) co 1. O U') Nr M N a CC w cn cn D CC W Fittings Used Summary 2 c O (0 _U (0 0 v Q) x c 0 ar w0 '. ca — D N O U ct . 0 N H Z cw rn� CD U) QXi LZ Q O N CO N O CO O tC) () N - () N (0 -'-000 o -o t()� X000 L() 0 — e-0)000 o vcoaoo00 LC) M n n 0 0 0 n 0 N (0 (0 0 0 0 N 0 N LO (n000 CO t() e- V' CO 000 •• 0 CO CO 000 N to N N 0 0 0 O 0 • N N 0 0 0 0 0 t() L--000 N (0 '.-000 O 0 CO N ecr O '- .- N M r (0 0) N sT V -N 1,- N1 , ' (V Ne - C) M N t U c 3 > a 3 = ca Ce 0 N `W a)a) ( COO)HI C U 3 ax) a) ax) '' o o.aa ¶:' - O (Do a 0. 0' W U' H » • 0 c (n c E c (nom Q) w D w E rn D OJLLa Flow Summary - NFPA 2007 • A-Pex Design Services, Inc. -EP TL INVESTMENT GROUP LOT 4 - One Head Calculation (H.5) Page 4 Date 11/19/2012 SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure STR 70.0 65 300.0 69.973 18.0 52.838 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes H.5 116.0 H.4 116.0 T.27 116.0 T.26 116.0 H.3 116.0 T.25 116.0 T.21 116.0 T.30 108.0 T.29 108.0 S.1 104.0 MTR 100.0 STR 100.0 T.33 116.0 T.36 116.0 H.12 116.0 T.34 116.0 T.32 116.0 T.31 108.0 H.9 108.0 H.17 116.0 H.20 116.0 T.43 116.0 T.41 116.0 T.42 108.0 T.40 108.0 H.16 108.0 H.19 108.0 H.7 108.0 H.8 108.0 H.13 116.0 T.37 116.0 T.38 116.0 T.39 108.0 H.14 108.0 H.6 108.0 T.28 108.0 H.11 116.0 T.35 116.0 H.1 116.0 T.23 116.0 T.22 116.0 H.2 116.0 4.3 17.52 18.0 18.32 18.45 18.58 18.74 18.9 19.26 23.06 24.09 26.82 51.03 52.84 17.97 18.26 18.66 18.85 19.14 22.86 22.95 18.49 18.71 18.83 19.04 22.7 22.71 22.76 22.78 22.83 22.85 18.94 18.95 19.05 22.72 22.79 23.03 23.23 18.86 18.95 18.98 18.99 19.4 18.93 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - NFPA 2007 `A-Pex Design Services, Inc. -EP TL INVESTMENT GROUP LOT 4 - One Head Calculation (H.5) Page 5 Date 11/19/2012 NODE ANALYSIS (cont.) Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes T.24 H.15 H.18 116.0 116.0 108.0 18.95 18.95 22.71 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams ' A-Pex Design Services, Inc. -EP TL INVESTMENT GROUP LOT 4 - One Head Calculation (H.5) Page 6 Date 11/19/2012 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Notes ****** H.5 6.99 0.862 1 Uel 11.0 13.000 17.520 to 150.0 0.0 12.000 0.0 H.4 6.99 0.0320 0.0 25.000 0.800 K Factor = 4.30 Vel = 3.84 H.4 to T.27 0.0 6.99 0.862 150.0 0.0320 1 Utr 2.0 0.0 0.0 2.000 2.000 4.000 18.320 0.0 0.128 Vel = 3.84 T.27 to T.26 0.0 6.99 0.862 150.0 0.0320 1 Utr 2.0 0.0 0.0 2.000 2.000 4.000 18.448 0.0 0.128 Vel = 3.84 T.26 to H.3 0.0 6.99 0.862 150.0 0.0320 0.0 0.0 0.0 5.000 0.0 5.000 18.576 0.0 0.160 Vel = 3.84 H.3 to T.25 0.0 6.99 0.862 150.0 0.0320 1 Utr 2.0 0.0 0.0 3.000 2.000 5.000 18.736 0.0 0.160 Vel = 3.84 T.25 to T.21 -2.87 4.12 0.862 150.0 0.0121 1Uel 11.0 1 Utb 17.0 0.0 4.000 26.000 30.000 18.896 0.0 0.362 Vel = 2.27 T.21 to T.30 0.0 4.12 0.862 150.0 0.0120 1 Utb 17.0 0.0 0.0 14.000 14.000 28.000 19.258 3.465 0.337 Vel = 2.27 T.30 to T.29 5.17 9.29 0.862 150.0 0.0543 1 Utb 1 Utr 17.0 2.0 0.0 3.000 16.000 19.000 23.060 0.0 1.032 Vel = 5.11 T.29 to S.1 8.71 18.0 1.054 150.0 0.0693 1T 2.44 12.000 24.092 0.0 2.440 1.732 0.0 14.440 1.000 Vel = 6.62 S.1 0.0 1.049 2E 6.044 170.000 26.824 to 150.0 0.0 6.044 11.732 MTR 18.0 0.0709 0.0 176.044 12.474 * Fixed loss = 10 Vel = 6.68 MTR 0.0 1.025 1E 2.7 12.000 51.030 to 150.0 1T 6.75 10.800 0.0 STR 18.0 0.0793 1G 1.35 22.800 1.808 Vel = 7.00 0.0 18.00 52.838 K Factor = 2.48 H.5 11.01 0.862 1 Utr 2.0 4.000 17.520 to 150.0 0.0 2.000 0.0 T.33 11.01 0.0743 0.0 6.000 0.446 Vel = 6.05 T.33 0.0 0.862 1 Utr 2.0 2.000 17.966 to 150.0 0.0 2.000 0.0 T.36 11.01 0.0742 0.0 4.000 0.297 Vel = 6.05 T.36 -5.47 0.862 1 Utr 2.0 3.000 18.263 to 150.0 1 Utb 17.0 16.000 0.0 H.12 5.54 0.0208 0.0 19.000 0.395 Vel = 3.05 H.12 0.0 0.862 0.0 9.000 18.658 to 150.0 0.0 0.0 0.0 T.34 5.54 0.0209 0.0 9.000 0.188 Vel = 3.05 T.34 -1.82 0.862 1 UeI 11.0 3.000 18.846 to 150.0 1 Utb 17.0 26.000 0.0 T.32 3.72 0.0100 0.0 29.000 0.289 Vel = 2.05 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams 'A-Pex Design Services, Inc. -EP TL INVESTMENT GROUP LOT 4 - One Head Calculation (H.5) Page 7 Date 11/19/2012 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Notes ****** T.32 0.0 0.862 1 Utb 17.0 12.000 19.135 to 150.0 0.0 14.000 3.465 T.31 3.72 0.0099 0.0 26.000 0.258 Vel = 2.05 T.31 1.45 0.862 0.0 5.000 22.858 to 150.0 0.0 0.0 0.0 H.9 5.17 0.0184 0.0 5.000 0.092 Vel = 2.84 H.9 0.0 0.862 1 Utr 2.0 4.000 22.950 to 150.0 0.0 2.000 0.0 T.30 5.17 0.0183 0.0 6.000 0.110 Vel = 2.84 0.0 5.17 23.060 K Factor = 1.08 T.36 5.48 0.862 1 Utr 2.0 9.000 18.263 to 150.0 0.0 2.000 0.0 H.17 5.48 0.0204 0.0 11.000 0.224 Vel = 3.01 H.17 0.0 0.862 1 Utr 2.0 9.000 18.487 to 150.0 0.0 2.000 0.0 H.20 5.48 0.0205 0.0 11.000 0.225 Vel = 3.01 H.20 0.0 0.862 0.0 6.000 18.712 to 150.0 0.0 0.0 0.0 T.43 5.48 0.0203 0.0 6.000 0.122 Vel = 3.01 T.43 -2.36 0.862 1 UeI 11.0 3.000 18.834 to 150.0 1 Utb 17.0 26.000 0.0 T.41 3.12 0.0072 0.0 29.000 0.209 Vel = 1.72 T.41 0.0 0.862 1 Utb 17.0 13.000 19.043 to 150.0 0.0 14.000 3.465 T.42 3.12 0.0072 0.0 27.000 0.194 Vel = 1.72 T.42 -1.66 0.862 1 Utr 2.0 1.000 22.702 to 150.0 0.0 2.000 0.0 T.40 1.46 0.0017 0.0 3.000 0.005 Vel = 0.80 T.40 0.0 0.862 1 UeI 11.0 15.000 22.707 to 150.0 1 Utr 2.0 14.000 0.0 H.16 1.46 0.0018 0.0 29.000 0.051 Vel = 0.80 H.16 0.0 0.862 0.0 10.000 22.758 to 150.0 0.0 0.0 0.0 H.19 1.46 0.0018 0.0 10.000 0.018 Vel = 0.80 H.19 0.0 0.862 1 UeI 11.0 17.000 22.776 to 150.0 0.0 12.000 0.0 H.7 1.46 0.0018 0.0 29.000 0.051 Vel = 0.80 H.7 0.0 0.862 1 Utr 2.0 9.000 22.827 to 150.0 0.0 2.000 0.0 H.8 1.46 0.0017 0.0 11.000 0.019 Vel = 0.80 H.8 0.0 0.862 1 Utr 2.0 5.000 22.846 to 150.0 0.0 2.000 0.0 T.31 1.46 0.0017 0.0 7.000 0.012 Vel = 0.80 0.0 1.46 22.858 K Factor = 0.31 T.43 2.36 0.862 1 Utr 2.0 23.000 18.834 to 150.0 0.0 2.000 0.0 H.13 2.36 0.0043 0.0 25.000 0.107 Vel = 1.30 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams • A-Pex Design Services, Inc. -EP Page 8 TL INVESTMENT GROUP LOT 4 - One Head Calculation (H.5) Date 11/19/2012 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Notes ****** H.13 0.0 0.862 1 Utr 2.0 1.000 18.941 to 150.0 0.0 2.000 0.0 T.37 2.36 0.0043 0.0 3.000 0.013 Vel = 1.30 T.37 0.25 0.862 1 Utb 17.0 5.000 18.954 to 150.0 0.0 14.000 0.0 T.38 2.61 0.0052 0.0 19.000 0.098 Vel = 1.43 T.38 0.0 0.862 1 UeI 11.0 14.000 19.052 to 150.0 1 Utb 17.0 26.000 3.465 T.39 2.61 0.0052 0.0 40.000 0.207 Vel = 1.43 T.39 1.66 0.862 1 Utr 2.0 3.000 22.724 to 150.0 0.0 2.000 0.0 H.14 4.27 0.0130 0.0 5.000 0.065 Vel = 2.35 H.14 0.0 0.862 1 Utr 2.0 17.000 22.789 to 150.0 0.0 2.000 0.0 H.6 4.27 0.0128 0.0 19.000 0.244 Vel = 2.35 1-.6 0.0 0.862 1 UeI 11.0 3.000 23.033 to 150.0 0.0 12.000 0.0 T.28 4.27 0.0129 0.0 15.000 0.193 Vel = 2.35 T.28 4.43 0.862 1 Utr 2.0 2.000 23.226 to 150.0 1 Utb 17.0 16.000 0.0 T.29 8.7 0.0481 0.0 18.000 0.866 Vel = 4.78 0.0 8.70 24.092 K Factor = 1.77 T.34 1.82 0.862 1 Utr 2.0 2.000 18.846 to 150.0 0.0 2.000 0.0 H.11 1.82 0.0028 0.0 4.000 0.011 Vel = 1.00 H.11 0.0 0.862 1 Utb 17.0 22.000 18.857 to 150.0 0.0 14.000 0.0 T.35 1.82 0.0026 0.0 36.000 0.095 Vel = 1.00 T.35 -0.25 0.862 1 Utr 2.0 10.000 18.952 to 150.0 0.0 2.000 0.0 H.1 1.57 0.0020 0.0 12.000 0.024 Vel = 0.86 I-1.1 0.0 0.862 1 Utr 2.0 4.000 18.976 to 150.0 0.0 2.000 0.0 T.23 1.57 0.0022 0.0 6.000 0.013 Vel = 0.86 T.23 2.86 0.862 1 UeI 11.0 4.000 18.989 to 150.0 1 Utb 17.0 26.000 0.0 T.22 4.43 0.0138 0.0 30.000 0.414 Vel = 2.44 T.22 0.0 0.862 1 Utb 17.0 12.000 19.403 to 150.0 0.0 14.000 3.465 T.28 4.43 0.0138 0.0 26.000 0.358 Vel = 2.44 0.0 4.43 23.226 K Factor = 0.92 T.25 2.86 0.862 1 Utr 2.0 3.000 18.896 to 150.0 0.0 2.000 0.0 H.2 2.86 0.0062 0.0 5.000 0.031 Vel = 1.57 H.2 0.0 0.862 0.0 4.000 18.927 to 150.0 0.0 0.0 0.0 T.24 2.86 0.0062 0.0 4.000 0.025 Vel = 1.57 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A-Pex Design Services, Inc. -EP Page 9 TL INVESTMENT GROUP LOT 4 - One Head Calculation (H.5) Date 11/19/2012 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Notes ****** T.24 to T.23 T.35 to 1-1.15 0.0 2.86 0.0 2.86 0.25 0.25 0.862 150.0 0.0062 1 Utr 2.0 0.0 0.0 4.000 2.000 6.000 18.952 0.0 0.037 Vel = 1.57 18.989 K Factor = 0.66 0.862 150.0 0.0 0.0 0.0 0.0 3.000 0.0 3.000 18.952 0.0 0.0 Vel = 0.14 H.15 to T.37 T.42 to H.18 H.18 to T.39 0.0 0.25 0.0 0.25 1.66 1.66 0.862 150.0 0.0001 1Uel 11.0 0.0 0.0 11.000 12.000 23.000 18.952 0.0 0.002 Vel = 0.14 18.954 K Factor = 0.06 0.862 150.0 0.0020 0.0 0.0 0.0 2.000 0.0 2.000 22.702 0.0 0.004 Vel = 0.91 0.0 1.66 0.862 150.0 0.0022 1 Utr 2.0 0.0 0.0 6.000 2.000 8.000 22.706 0.0 0.018 Vel = 0.91 0.0 1.66 22.724 K Factor = 0.35 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 5Up191.Y 5TATIC P51: 70 n ESInUAL P51: 65 PLOW GPM: 300 160' OR I " POLY TOM TN METER TO 5.1- 1" WTER 12' a I" COPPER FROM 11-E 511REET WAO? 5V I a nMIL N.T.5 MOST NEAP # N.5 1111 & H.12 -1YP AL ICALLY REMOTE NAPS GPM PE55L1�E 18 26 Q11/1 AT 5111 52.84 61.22 0 ITC43-16 0 RFC43-18 OVK -I60-200 17 RfIA13LE Model ? C432FC43 Concealed Pendent Sprinkler 155E°, 3/ 8" Orifice, Maximum Spacing 16'x16' Sprinkler head demand: 13 qpm @ 9,14 RfIA6LE Model REC43?EC43 Concealed Pendent Sprinkler 155F°, 3/ 8" Orifice, Maximum Spacing 18'x18 Sprinkler head demand: 18 qpm @ 17,52 5EE SUBMITTAL NAT SOURCE \FI9A Ian 12151-ANC5 FLOW HAr 50Ut?C5 ORIINARY TEMP IN. INIERMEtIATE TEMP IN. 5IPF OE PIEPLACE 36" 12" FRONT 0 PI PLACE 60" 36" W0012 IX RNING 5TOVE 42" 12" KITCHEN RANGE 18" 9" WALL OVEN 18" 91 N01" Alp PLUE5 18" 9" UNIN5LLA1En HEAT PUCTS 18" 9" UNINSLLATEV HOT WATER PIPE5 12" 6" 5IPF OP HOf AIR PIEPU5ER 24" 12" FRONT OP HOf AR PIPPU5ER 6" 18" NOT WATER NEATER 611 11 FURNACE 611 OW -250W LIGHT PIXTL?E 6" 250W -499W LIGHT PIXTLRE 12" 6" MUL11-PUpPO5FLOW 5WI1'CH IN5fALLA1iON N,r,s T1-115 51,GGF5Tn LAYOUT 15 I3ASv12 UPON INFORMATION PROV1PFP 13Y 011-ER5, CHANGES IN CONSTRUCTION OR FIELV CONPITIONS MAY OCCLR W1 -ICH MAY REQUIRE CHANGES T0 11 -F LAYOL1" IT 15 TN RE5PONSIPILITY OP TI -E INSTALLER TO NOTIFY APEX nE51GN RVICE5 0' SLCH CI-IANGF5, HA2 OCA #I0 Af11 C EGRESS COLON/ LIN1YM 1.aN12 GLUE LINES- FFFP TO FIXTURES C 6ATN, 5-0WER, ETC.) GUN LINES= IN1F?1,VCL CONNFCfIONS. BLACK LINE5-- SPRINKLER NEAP TO SPRINKLER INEAn, - 1/ 2" PIPE SIZE 3/ 4" PIPE SIZE I PIPE 5IZE - 1 1/4" PIPE 5IZE 2" PIPE SIZE IR 60'x30' (VTO) _ RFC45=16 601x361 SHOWER 5068 BI -PASS KO �• , • 1 C 5� I" 90 2 Ge L -30W5 FAC1-0F 2 1X1'0 CALCULA1'I0\ F01? I\'�p��V;L- �1\--" O\G AT11Ci 0 V'/ th ut: Comments As Noted In Red Per The Attached Letter These plans have bei nevict e,d by The Tukwila Fire Prevention Bureau fo coni''n'k nce ,r: th current City standards F t c , to errors and omissions whit.; r.. , ' »oiations of adopted standards and ;;,,{.. ,c,, resoon5ibility for the adequacy of c, :>+ r i Air, tie designer. Additions, lei?:_:„ ''.se drawings after this date will vGi t r ;u're a resubiiirtt<&i of r.: ... _,i : :45 .,i b c14iG nt approval. '?nal acceptance is e.st'and Inspection by ? le Tui:wlia i li S;: 1te: Z� �'� ' Y `'' %a►1^^%�� IUKWILA FIRE DEPARTMENT Please call 2O6-575-4407 and give this Fire Permit No. and exact address for shut- down or restoration approval. I\ il?,VNL COI\ CLOSET CLOSET Nov �,`°� VK -16C59200 / , ALARM �f91 f I (-IP.° 11' .OFT 54 2068 2'-b _ ,IS X 14 RFC4 -16 10 5ELc EGRESS EGRESS 303C FX EGRESS \C110\5 'rt (010,01 w; 3'►-. &4l 4/k.t� PvSI °i 4u.�y1 .ov s 14, 4, 5 4Yl . •* 1.1- dvtw req,.► • �ioc✓(b ) 4-eretviye..J►• 6 I 1 ALARM 3� 1"0 L 0CA0\ A.313155 01 3UILI\G LL 2'-0' • fiFORM Iti' AF5-1 TOW 5W11 -CH 1115k' A55M31,Y Elb IC P pER 42' MANUF. GAS F ''EPLACE INSTALL PER MFRS, SPECS 5' ISLAND H — PROV E RESTRAINT S , 508.2 OF 2009 U� ° OLLARD IkOVIDE PRESSURE RELI VALVE TO EXTERIOR AND , i,ALI1\15APPROVED A ;506 N TANK. VCS)11 Qe 20 ATED 2%8 4 -16 IS' X2a H Ij' Al ACCE° SPA l C 1F64 -16 OFFICE/ EN 11' x V' 1 PROVIDE ONE AYER 543' GWB TYPE °X' AT CEILINGS.COMMO, UJITH HABITABLE AREAS WHERE THE PARATION 15 A FLOOR - CEILING ASSEMBLY, CLAD ALL SUPPORT COLUMNS, BEAMS A,,'. UJALLS WITH ONE LAYER 1/2' GWB. -THE GARAGE SHALL BE 5 7ARATED FROM THE RESIDENCE AND ATTIC A EA WITH NO LESS THAN 1/2° GWB ON THE GAD GE SIDE. 10'-10° 1,o Main 5 Pl icftEoop .• DESIGN 121119-01N ALLIANCE In#: SERA MILE 5pt?INKL CONTACT: J051- TREMMEL 1073147th PI W Mukilteo, WA 98275 PN: 425-493-9680 PAX: 425-493-9717 425-760-4240 SCALE: SALES ?EP: LE5IGNEn 13Y: KAREN 13A13C3 RE5IPENTIAL FIRE PROTECTION 5Y5TEM STEPNANIF RAHEY 1lJ TYPE: 1 / 2 - 3/ 4" - I" AQUAPEX RINKLFR INFORMATION # OF NEAPS TI -115 S1 -EFT - 21 # OP 1-1EAn511-15 J013 - 21 STATIC P55L?E 15- 70 I L ONLY FOR 1)E 10 `V� toCertincare S 4P 0 oa `1A\. OQ�.e Stephan: Marie Fahey n V;fie ti0 Palidjo, lection Sprtok�et eta, ° throut°b gh Elect 0 _ \ \ \ O \\ \ ...7 CZ \\ \ o o -----\ > \ I 2 3 4 REM. & CON5T 11-19-12 Q0. ?EV150N/ 155LE PATE .4, rROJECT # : 121119-01N ALLIANCE In#: COMPANY: 50LNVIEW PLUMBING CONTACT: J051- TREMMEL CONTACT PHONE # : 425-760-4240 SCALE: I/ 4" = 11-0" LE5IGNEn 13Y: KAREN 13A13C3 CI-tanC3Y: STEPNANIF RAHEY VERTIFICA110N #: 109-04-4594.1 L PI00 MA \ FI,00 I/II I10I1 00 144111 42:-334 DEC 1,9 2012 TUKWILA FIRE