Loading...
HomeMy WebLinkAboutPP - 4054 S 146TH ST - UNKNOWN - PERMITS AND PLANS4054 S 146TH ST ASSOCIATED PERMITS 12-S-263 D12-275 4ist SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address! 4U S q 10 Sj" Tenant Name: Property Owner's Name: Mailing Address: Date application accepted: pAID 2333 DIC 19 2012 TUIdLA FIRE King Co. Assessor's Tax No.: }_ Suite Number: 1(Il 2 Floor: New Tenant? ❑ - Yes ❑ - No CONTACT PERSON -if there are questions about the submittal. Name: Z-61 h TT12-e IA ) Company Name;C(j i /V (/1 V AU (U P V) 1c1 , I/0 Mailing Address 2041111‘ S k f Aleil kiWell a� E-mail Address: 3014 76 Y ���� City State Zip Day Telephone: 300 -fi0 3 ) Wj 0 w,4 9.9? -z5 2 tate Zi Fax Number:3146 40S3 S') re ,sysem Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. • I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Day Telephone: Plan Permit App.doc 5/14/10 Date: TFD FP Form 8 INSPECTION RECORD Retain a copy with p 0�3tSOd INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: 'r L .1 c>42y►6k Type of Inspection: Ct /`e- c "w__ Address: q p c c{ Suite #: r S i y 6 Contact Person: Special Instructions: Permits: Phone No.: gApproved per applicable codes. 1 Corrections required prior to approval. COMMENTS: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:IPLI 4---a-- Date: (�/G// 5 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 a INSPECTION NUMBER INSPECTION RECORD Retain a copy }rvi rmit-7y. L? PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: TL- 1 11/4RveS4-Me. —g Type of Inspection: P /JAL Address:Li sl . S, /q6 . f,_ Suite #: b Contact Person: Special Instructions: Phone No.: -Approved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: iik gy,„.s—a-- Date: 436 3 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip:: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permitPi? - 7 Gt PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: L Jo&e5-Le � s Type of Inspection: {)1� 0r \co (i --a, K - Address: i LI1 Suite #: Monitor: Contact Person: Permits: Occupancy Type: Special Instructions: /boo 12dt' Phone No.: Approved per applicable codes. nCorrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 5il /boo 12dt' 57/,)1 I._ i v-7 /07 � I' (.t. e �e-- t � f 'e. 5 \-- --_ 0 (c.. ( - A-.1-47 fry v/L. d k _ -Ta Ce -7U` -'V - Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: a\ Date: 2ig-)// Hrs.: a $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip:: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 A-Pex Design Services, Inc. -EP 10731 47th PI W Mukilteo, WA 98275 425-493-9680 Job Name : TL INVESTMENT GROUP LOT 2 - One Head Calculation (H.6) Drawing Location : 4052 S 146th STREET TUKWILLA WA 98168 Remote Area Contract : 121119-02 Data File : 121119-02 TL Investment Group Lot 2.wx1 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A-Pex Design Services, Inc. -EP TL INVESTMENT GROUP LOT 2 - One Head Calculation (H.6) HYDRAULIC DESIGN INFORMATION SHEET Name - TL INVESTMENT GROUP LOT 2 Location - TUKWILLA WA 98168 Building - Contractor - SOUNDVIEW PLUMBING Calculated By - KAREN BABB Construction: (X) Combustible ( ) OCCUPANCY - RESIDENTIAL Date - 11-19-12 System No. - Contract No. - 121119-02 Drawing No. - Non -Combustible Ceiling Height Page 1 Date 11/19/2012 S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: (X)1 ( )2 ( )4 ( ) S ( )Other Made by Date T ( )Specific Ruling E M Listed Flow at Start Point - 18 Listed Pres. at Start Point - 17.52Psi D MAXIMUM LISTED SPACING 18x 18 E Domestic Flow Added - S Additional Flow Added - I Elevation at Highest Outlet - 116 G Note: N Gpm System Type (X) Wet ( ) Dry ( ) Deluge ( ) PreAction Gpm Sprinkler or Nozzle Gpm Make RELIABLE Model RFC43 Feet Size 3/8 K -Factor 4.3 Temperature Rating 155 Calculation Summary Gpm Required 18 C -Factor Used: Psi Required 47.95 At Ref Pt STR Overhead 150 Underground 150 W Water Flow Test: A Date of Test - T Time of Test - E Static (Psi) - 70 R Residual (Psi) - 65 Flow (Gpm) - 300 S Elevation - 100 Pump Data: Rated Cap. @ Psi Elev. Other Tank or Reservoir: Cap. Elev. Well Proof Flow Gpm P Location: P L Source of Information: Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 MM a0 Water Supply Curve (C) One Head Calculation (H.6) N WO ' J c a. uO ow a) H Z W 0) pW X> a) Z a QI- ocoS co" cNI r)m0070 O?O coN • c • c 3N^� oE-aa) u - Q C0 c oEEEE'rn >nv0' (/) (i) (i)�` .10.41) � ,NN OM a3 o0002OO) E a) 0 O 1) co. a0 a - O < O Z 0 J 0 0 0- M Nr N O 00 0 0 0 0 OM 0 O ol CL W (n 0) O CC W 0 (NI 0 O N O 10 0 0 0 1.0 Windham N.H. USA 03087 Fittings Used Summary fD 2 c O 0 0 U N U N N N c 0 CLw0 U a C N Et .2 0 1 - UJ Z W O7.2 ppW cpZ < 1-- N Cp%C.:21-000 N 111 a-0 0 0 CO LO n-O0) 000 r ,- • Co0000O cqrsr,c3rpo � N- CO((00000 O N IO L0 0 0 0 CO CO '•(0")000 CO-ChM000 In ‘-NN000 V' 1-NN000 N (h cpa-�OOO in Cr) rrr000 N N N Cpr-x-000 000 h N in Ch CV '- .t n- CO •t-rN r • cnCOr-rnv V- Nr Co ,-�N n N,- v- N d) c E rnZ J 0) N -. Li- < N 1- M Ch N r s U C >3 f0 N m 2 W v N C9 (0 L 0) 1- 1- c o 3 a) N a) CO 'C o C1 0. C1 co c CL 2 7 2 ob avo• a)C9rn000 « JD W01-000 Units Summary L U :: c ca) N Q N L C N O C/) Co 'O N C9 c O N (J) 00 u_ 0_ w w c N c � "E' 0 , 7 E03V) Co 0 2 5JLL.a Windham N.H. USA 03087 0 N0 I.L U C U r C6 T T .0 Cn E 0) O 0 0 a E O U Flow Summary - NFPA 2007 A-Pex Design Services, Inc. -EP TL INVESTMENT GROUP LOT 2 - One Head Calculation (H.6) Page 4 Date 11/19/2012 SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure STR 70.0 65 300.0 69.973 18.0 47.95 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node H.6 116.0 T.27 116.0 T.28 116.0 T.23 108.0 H.3 108.0 H.2 108.0 H.8 108.0 h1.10 108.0 T.31 108.0 T.32 108.0 S.1 104.0 MTR 100.0 STR 100.0 Fi.1 116.0 H.5 116.0 T.25 116.0 H.9 116.0 T.29 116.0 T.30 116.0 T.26 116.0 H.7 116.0 H.12 116.0 T.33 116.0 T.35 116.0 T.36 108.0 H.13 116.0 H.16 116.0 T.39 116.0 H.19 116.0 T.45 116.0 T.44 116.0 T.42 108.0 H.18 108.0 T.34 116.0 H.14 116.0 T.41 116.0 T.40 116.0 T.37 108.0 T.38 108.0 H.17 108.0 1-1.21 108.0 H.4 108.0 4.3 17.52 18.0 18.15 18.41 22.59 22.62 22.93 23.05 23.28 23.38 23.56 30.44 46.14 47.95 17.96 18.46 18.66 18.84 19.02 19.5 18.25 18.68 18.96 19.07 19.29 23.34 19.04 19.07 19.1 19.12 19.14 19.27 22.85 23.03 19.09 19.11 19.13 19.15 22.66 22.7 22.72 22.78 22.62 Notes Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - NFPA 2007 A-Pex Design Services, Inc. -EP TL INVESTMENT GROUP LOT 2 - One Head Calculation (H.6) Page 5 Date 11/19/2012 NODE ANALYSIS (cont.) Pressure Discharge Node Tag Elevation Node Type at Node at Node H.15 108.0 H.20 116.0 22.65 19.14 Notes Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A-Pex Design Services, Inc. -EP TL INVESTMENT GROUP LOT 2 - One Head Calculation (H.6) Page 6 Date 11/19/2012 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Notes ****** H.6 11.34 0.862 1 Utr 2.0 6.000 17.520 K Factor = 4.30 to 150.0 0.0 2.000 0.0 T.27 11.34 0.0784 0.0 8.000 0.627 Vel = 6.23 T.27 -6.30 0.862 1 Utb 17.0 1.000 18.147 to 150.0 0.0 14.000 0.0 Vel = 2.77 T.28 5.04 0.0175 0.0 15.000 0.262 T.28 0.0 0.862 1 Utb 17.0 15.000 18.409 to 150.0 1 UeI 11.0 26.000 3.465 Vel = 2.77 T.23 5.04 0.0175 0.0 41.000 0.717 T.23 -1.28 0.862 1 Utr 2.0 1.000 22.591 to 150.0 0.0 2.000 0.0 H.3 3.76 0.0103 0.0 3.000 0.031 Vel = 2.07 H.3 0.0 0.862 1 UeI 11.0 16.000 22.622 to 150.0 1 Utr 2.0 14.000 0.0 H.2 3.76 0.0102 0.0 30.000 0.305 Vel = 2.07 H.2 0.0 0.862 1 Utr 2.0 10.000 22.927 to 150.0 0.0 2.000 0.0 H.8 3.76 0.0102 0.0 12.000 0.123 Vel = 2.07 H.8 0.0 0.862 1 UeI 11.0 11.000 23.050 to 150.0 0.0 12.000 0.0 H.10 3.76 0.0102 0.0 23.000 0.234 Vel = 2.07 H.10 0.0 0.862 1 Utr 2.0 7.000 23.284 to 150.0 0.0 2.000 0.0 T.31 3.76 0.0102 0.0 9.000 0.092 Vel = 2.07 T.31 4.80 0.862 1 Utr 2.0 2.000 23.376 to 150.0 0.0 2.000 0.0 T.32 8.56 0.0465 0.0 4.000 0.186 Vel = 4.71 T.32 9.44 0.862 1T 7.528 11.000 23.562 to 150.0 1 Utb 17.0 16.904 1.732 S.1 18.0 0.1844 0.0 27.904 5.145 Vel = 9.90 S.1 0.0 1.049 2E 6.044 50.000 30.439 * Fixed loss = 10 to 150.0 0.0 6.044 11.732 MTR 18.0 0.0709 0.0 56.044 3.971 Vel = 6.68 MTR 0.0 1.025 1E 2.7 12.000 46.142 to 150.0 1T 6.75 10.800 0.0 STR 18.0 0.0793 1G 1.35 22.800 1.808 Vel = 7.00 0.0 18.00 47.950 K Factor = 2.60 H.6 6.66 0.862 1 Utr 2.0 13.000 17.520 to 150.0 0.0 2.000 0.0 1-1.1 6.66 0.0293 0.0 15.000 0.440 Vel = 3.66 H.1 0.0 0.862 1 Utr 2.0 15.000 17.960 to 150.0 0.0 2.000 0.0 H.5 6.66 0.0294 0.0 17.000 0.499 Vel = 3.66 H.5 0.0 0.862 1 Utr 2.0 5.000 18.459 to 150.0 0.0 2.000 0.0 T.25 6.66 0.0293 0.0 7.000 0.205 Vel = 3.66 T.25 0.0 0.862 1 Utr 2.0 4.000 18.664 to 150.0 0.0 2.000 0.0 H.9 6.66 0.0293 0.0 6.000 0.176 Vel = 3.66 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A-Pex Design Services, Inc. -EP TL INVESTMENT GROUP LOT 2 - One Head Calculation (H.6) Page 7 Date 11/19/2012 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Notes ****** H.9 0.0 0.862 1 Utr 2.0 4.000 18.840 to 150.0 0.0 2.000 0.0 T.29 6.66 0.0293 0.0 6.000 0.176 T.29 -1.86 0.862 1 Utb 17.0 4.000 19.016 to 150.0 1 UeI 11.0 26.000 0.0 T.30 4.8 0.0160 0.0 30.000 0.479 T.30 0.0 0.862 1 Utb 17.0 12.000 19.495 to 150.0 0.0 14.000 3.465 T.31 4.8 0.0160 0.0 26.000 0.416 0.0 4.80 23.376 T.27 6.30 0.862 1 Utr 2.0 2.000 18.147 to 150.0 0.0 2.000 0.0 T.26 6.3 0.0262 0.0 4.000 0.105 T.26 0.0 0.862 1 UeI 11.0 4.000 18.252 to 150.0 0.0 12.000 0.0 H.7 6.3 0.0264 0.0 16.000 0.423 H.7 0.0 0.862 1 Utr 2.0 9.000 18.675 to 150.0 0.0 2.000 0.0 H.12 6.3 0.0264 0.0 11.000 0.290 H.12 0.0 0.862 1 Utr 2.0 2.000 18.965 to 150.0 0.0 2.000 0.0 T.33 6.3 0.0265 0.0 4.000 0.106 T.33 -1.73 0.862 1 Utb 17.0 1.000 19.071 to 150.0 0.0 14.000 0.0 T.35 4.57 0.0146 0.0 15.000 0.219 T.35 0.0 0.862 1 UeI 11.0 14.000 19.290 to 150.0 1 Utb 17.0 26.000 3.465 T.36 4.57 0.0146 0.0 40.000 0.584 T.36 4.87 0.862 1 Utr 2.0 2.000 23.339 to 150.0 0.0 2.000 0.0 T.32 9.44 0.0558 0.0 4.000 0.223 0.0 9.44 23.562 T.29 1.86 0.862 1 Utr 2.0 8.000 19.016 to 150.0 0.0 2.000 0.0 H.13 1.86 0.0028 0.0 10.000 0.028 H.13 0.0 0.862 1 Utr 2.0 7.000 19.044 to 150.0 0.0 2.000 0.0 H.16 1.86 0.0028 0.0 9.000 0.025 H.16 0.0 0.862 1 Utr 2.0 8.000 19.069 to 150.0 0.0 2.000 0.0 T.39 1.86 0.0027 0.0 10.000 0.027 T.39 0.0 0.862 1 Utr 2.0 5.000 19.096 to 150.0 0.0 2.000 0.0 H.19 1.86 0.0029 0.0 7.000 0.020 1-.19 0.0 0.862 1 Utr 2.0 6.000 19.116 to 150.0 0.0 2.000 0.0 T.45 1.86 0.0028 0.0 8.000 0.022 Vel = 3.66 Vel = 2.64 Vel = 2.64 K Factor = 0.99 Vel = 3.46 Vel = 3.46 Vel = 3.46 Vel = 3.46 Vel = 2.51 Vel = 2.51 Vel = 5.19 K Factor = 1.94 Vel = 1.02 Vel = 1.02 Vel = 1.02 Vel = 1.02 Vel = 1.02 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A-Pex Design Services, Inc. -EP TL INVESTMENT GROUP LOT 2 - One Head Calculation (H.6) Page 8 Date 11/19/2012 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. C or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn ******* Notes ****** T.45 to T.44 0.59 T.44 to T.42 2.45 0.0 T.42 to H.18 2.45 H.18 to T.36 2.42 4.87 T.33 to T.34 T.34 to H.14 H.14 to T.41 T.41 to T.40 T.40 to T.37 T.37 to T.38 T.38 to H.17 H.17 to H.21 H.21 to T.42 0.0 4.87 0.0 4.87 1.72 0.862 150.0 0.0046 0.862 150.0 0.0046 0.862 150.0 0.0164 0.862 150.0 0.0164 1UeI 11.0 1 Utb 17.0 0.0 1 Utb 17.0 0.0 0.0 1 Utr 2.0 0.0 0.0 1UeI 11.0 0.0 0.0 2.000 26.000 28.000 19.138 0.0 0.129 11.000 14.000 25.000 19.267 3.465 0.115 9.000 2.000 11.000 22.847 0.0 0.180 7.000 12.000 19.000 23.027 0.0 0.312 Vel = 1.35 Vel = 1.35 Vel = 2.68 Vel = 2.68 1.72 0.0 1.72 0.0 1.72 -0.58 1.14 0.0 1.14 1.28 2.42 0.0 2.42 0.0 2.42 T.23 to H.4 0.0 2.42 0.0 2.42 1.28 0.862 150.0 0.0024 0.862 150.0 0.0024 0.862 150.0 0.0024 0.862 150.0 0.0011 0.862 150.0 0.0011 0.862 150.0 0.0045 0.862 150.0 0.0045 0.862 150.0 0.0045 0.862 150.0 0.0045 1 Utr 2.0 0.0 0.0 1 Utr 2.0 0.0 0.0 1 Utr 2.0 0.0 0.0 1 Utb 17.0 0.0 0.0 1 Utb 17.0 1UeI 11.0 0.0 1 Utr 2.0 0.0 0.0 1 Utr 2.0 0.0 0.0 1 Utr 2.0 0.0 0.0 0.0 0.0 0.0 23.339 K Factor = 1.01 5.000 19.071 2.000 0.0 7.000 0.017 Vel = 0.95 6.000 19.088 2.000 0.0 8.000 0.019 Vel = 0.95 8.000 19.107 2.000 0.0 10.000 0.024 Vel = 0.95 3.000 19.131 14.000 0.0 17.000 0.019 Vel = 0.63 17.000 19.150 26.000 3.465 43.000 0.048 Vel = 0.63 6.000 22.663 2.000 0.0 8.000 0.036 Vel = 1.33 2.000 22.699 2.000 0.0 4.000 0.018 Vel = 1.33 11.000 22.717 2.000 0.0 13.000 0.058 Vel = 1.33 16.000 22.775 0.0 0.0 16.000 0.072 Vel = 1.33 22.847 1.28 H.4 to H.15 0.0 1.28 0.862 150.0 0.0014 0.862 150.0 0.0014 1UeI 11.0 0.0 0.0 1 Utr 2.0 0.0 0.0 8.000 12.000 20.000 22.591 0.0 0.028 23.000 2.000 25.000 22.619 0.0 0.034 K Factor = 0.51 Vel = 0.70 Vel = 0.70 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A-Pex Design Services, Inc. -EP TL INVESTMENT GROUP LOT 2 - One Head Calculation (H.6) Page 9 Date 11/19/2012 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn ******* Notes ****** H.15 0.0 0.862 1 Utr 2.0 5.000 22.653 to 150.0 0.0 2.000 0.0 T.37 1.28 0.0014 0.0 7.000 0.010 Vel = 0.70 0.0 1.28 22.663 K Factor = 0.27 T.41 0.59 0.862 1 Uel 11.0 7.000 19.131 to 150.0 0.0 12.000 0.0 H.20 0.59 0.0003 0.0 19.000 0.006 Vel = 0.32 H.20 0.0 0.862 0.0 2.000 19.137 to 150.0 0.0 0.0 0.0 T.45 0.59 0.0005 0.0 2.000 0.001 Vel = 0.32 0.0 0.59 19.138 K Factor = 0.13 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A-Pex Design Services, Inc. -EP 10731 47th PI W Mukilteo, WA 98275 425-493-9680 Level oi.. c° r. c� o a Stephanie Marie Fahey 3 199-04.2131 •.<,-, Job Name : TL INVESTMENT GROUP LOT 2 - Two Head Calculation (H.9 & H.12) Drawing Location : 1962 S 146th STREET TUKWILLA WA 98168 Remote Area : `1° Contract : 121119-02 Data File : 121119-02 TL Investment Group Lot 2.wx2 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A Pex Design Services, Inc. -EP TL INVESTMENT GROUP LOT 2 - Two Head Calculation (H.9 & H.12) Page 1 Date 11/19/2012 HYDRAULIC DESIGN INFORMATION SHEET Name - TL INVESTMENT GROUP LOT 2 Location - TUKWILLA WA 98168 Building - Contractor - SOUNDVIEW PLUMBING Calculated By - KAREN BABB Construction: (X) Combustible ( ) OCCUPANCY - RESIDENTIAL S Y S T E M Listed Flow at Start Point Date - 11-19-12 System No. - Contract No. - 121119-02 Drawing No. - Non -Combustible Ceiling Height Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R Number of Sprinklers Flowing: ( )1 (X)2 ( )4 ( ) ( )Other ( )Specific Ruling Made by (X)NFPA 13D Date Listed Pres. at Start Point - 9.14 16 D E S I G N MAXIMUM LISTED SPACING Domestic Flow Added Additional Flow Added Elevation at Highest Outlet Note: 13 Gpm Psi x 16 0 Gpm Gpm 116 Feet System Type (X) Wet ( ) Dry ( ) Deluge ( ) PreAction Sprinkler or Nozzle Make RELIABLE Model RFC43 Size 3/8 K -Factor 4.3 Temperature Rating 155 Calculation Gpm Required 26.1054 Summary C -Factor Used: Psi Required 50.52 At Ref Pt STR Overhead 150 Underground 150 W Water Flow Test: A Date of Test - T Time of Test - E Static (Psi) - 70 R Residual (Psi) - 65 Flow (Gpm) - 300 S Elevation - 100 Pump Data: Rated Cap. @ Psi Elev. Other Tank or Reservoir: Cap. Elev. Well Proof Flow Gpm P Location: P L Source of Information: Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) . N 0 N O) N N_ 2 o 2 O _U f6 U a 0 2 3 CLN w0 . J C d u O • Q' ▪ 0 • I - OZ � W rn2 l- a) 0) • ; Fittings Used Summary N O N O (0 0 W (ID U) TY TY TY M N (0 TYVY 000 oTYo U) '- .- 000 U) O TY • .-0)000 O `7 C000000 U) M I's r 000 n O N O (0 O OO N O N U) U) 0 0 0 CO U) V (")000 • 0 ( ) 0 0 0 N U) TY N N 0 0 0 O O A- N N 0 0 0 00 T -.-O00 U) 1 -TY TY 000 (0 TY N 0 0 0 U ) ▪ TY 0 TY • TY N • Nr (•I N,- U) TY CV 'n NY- V T- V- CV Units Summary L a) U C c17 L 7 Q N c N 0 a (/) (6 a, (9 c 0 a)EuDa. Flow Summary - NFPA 2007 A. Pex Design Services, Inc. -EP Page 4 TL INVESTMENT GROUP LOT 2 - Two Head Calculation (H.9 & H.12) Date 11/19/2012 SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure STR 70.0 65 300.0 69.945 26.11 50.524 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes H.9 116.0 T.29 116.0 T.30 116.0 T.31 108.0 T.32 108.0 S.1 104.0 MTR 100.0 STR 100.0 T.25 116.0 H.5 116.0 H.1 116.0 H.6 116.0 T.27 116.0 T.28 116.0 T.23 108.0 H.3 108.0 H.2 108.0 H.8 108.0 H.10 108.0 T.26 116.0 H.7 116.0 H.12 116.0 T.33 116.0 T.35 116.0 T.36 108.0 H.13 116.0 H.16 116.0 T.39 116.0 H.19 116.0 T.45 116.0 T.44 116.0 T.42 108.0 H.18 108.0 T.34 116.0 H.14 116.0 T.41 116.0 T.40 116.0 T.37 108.0 T.38 108.0 H.17 108.0 H.21 108.0 H.20 116.0 4.3 9.14 13.0 9.55 10.59 14.97 15.33 27.29 46.93 50.52 9.17 9.2 9.29 9.36 9.4 9.63 13.71 13.76 14.25 14.45 14.82 9.38 9.33 4.3 9.29 13.11 9.58 10.08 14.87 9.62 9.68 9.76 9.81 9.87 10.19 13.95 14.28 9.66 9.74 9.85 9.96 13.71 13.76 13.78 13.86 9.87 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - NFPA 2007 A-Pex Design Services, Inc. -EP Page 5 TL INVESTMENT GROUP LOT 2 - Two Head Calculation (H.9 & H.12) Date 11/19/2012 NODE ANALYSIS (cont.) Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes H.15 108.0 13.71 H.4 108.0 13.71 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams ArPex Design Services, Inc. -EP Page 6 TL INVESTMENT GROUP LOT 2 - Two Head Calculation (H.9 & H.12) Date 11/19/2012 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Notes ****** H.9 10.47 0.862 1 Utr 2.0 4.000 9.140 to 150.0 0.0 2.000 0.0 T.29 10.47 0.0677 0.0 6.000 0.406 K Factor = 4.30 Vel = 5.76 T.29 -3.14 0.862 1 Utb 17.0 4.000 9.546 to 150.0 1 Uel 11.0 26.000 0.0 T.30 7.33 0.0349 0.0 30.000 1.048 Vel = 4.03 T.30 0.0 0.862 1 Utb 17.0 12.000 10.594 to 150.0 0.0 14.000 3.465 T.31 7.33 0.0350 0.0 26.000 0.909 Vel = 4.03 T.31 4.85 0.862 1 Utr 2.0 2.000 14.968 to 150.0 0.0 2.000 0.0 T.32 12.18 0.0895 0.0 4.000 0.358 Vel = 6.70 T.32 13.92 0.862 1T 7.528 11.000 15.326 to 150.0 1 Utb 17.0 16.904 1.732 S.1 26.1 0.3668 0.0 27.904 10.235 Vel = 14.35 S.1 0.0 1.049 2E 6.044 50.000 27.293 to 150.0 0.0 6.044 11.732 MTR 26.1 0.1410 0.0 56.044 7.901 * Fixed loss = 10 Vel = 9.69 MTR 0.0 1.025 1E 2.7 12.000 46.926 to 150.0 1T 6.75 10.800 0.0 STR 26.1 0.1578 1G 1.35 22.800 3.598 Vel = 10.15 0.0 26.10 50.524 K Factor = 3.67 H.9 2.53 0.862 1 Utr 2.0 4.000 9.140 to 150.0 0.0 2.000 0.0 T.25 2.53 0.0048 0.0 6.000 0.029 Vel = 1.39 T.25 0.0 0.862 1 Utr 2.0 5.000 9.169 to 150.0 0.0 2.000 0.0 H.5 2.53 0.0050 0.0 7.000 0.035 Vel = 1.39 H.5 0.0 0.862 1 Utr 2.0 15.000 9.204 to 150.0 0.0 2.000 0.0 H.1 2.53 0.0049 0.0 17.000 0.083 Vel = 1.39 I-1.1 0.0 0.862 1 Utr 2.0 13.000 9.287 to 150.0 0.0 2.000 0.0 H.6 2.53 0.0049 0.0 15.000 0.073 Vel = 1.39 H.6 0.0 0.862 1 Utr 2.0 6.000 9.360 to 150.0 0.0 2.000 0.0 T.27 2.53 0.0049 0.0 8.000 0.039 Vel = 1.39 T.27 2.13 0.862 1 Utb 17.0 1.000 9.399 to 150.0 0.0 14.000 0.0 T.28 4.66 0.0152 0.0 15.000 0.228 Vel = 2.56 T.28 0.0 0.862 1 Utb 17.0 15.000 9.627 to 150.0 1 Uel 11.0 26.000 3.465 T.23 4.66 0.0151 0.0 41.000 0.620 Vel = 2.56 T.23 0.19 0.862 1 Utr 2.0 1.000 13.712 to 150.0 0.0 2.000 0.0 H.3 4.85 0.0163 0.0 3.000 0.049 Vel = 2.67 H.3 0.0 0.862 1 Uel 11.0 16.000 13.761 to 150.0 1 Utr 2.0 14.000 0.0 H.2 4.85 0.0163 0.0 30.000 0.490 Vel = 2.67 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A-Pex Design Services, Inc. -EP Page 7 TL INVESTMENT GROUP LOT 2 - Two Head Calculation (H.9 & H.12) Date 11/19/2012 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Notes H.2 0.0 0.862 1 Utr 2.0 10.000 14.251 to 150.0 0.0 2.000 0.0 H.8 4.85 0.0162 0.0 12.000 0.195 Vel = 2.67 H.8 0.0 0.862 1 Uel 11.0 11.000 14.446 to 150.0 0.0 12.000 0.0 H.10 4.85 0.0163 0.0 23.000 0.375 Vel = 2.67 H.10 0.0 0.862 1 Utr 2.0 7.000 14.821 to 150.0 0.0 2.000 0.0 T.31 4.85 0.0163 0.0 9.000 0.147 Vel = 2.67 0.0 4.85 14.968 K Factor = 1.25 T.27 -2.13 0.862 1 Utr 2.0 2.000 9.399 to 150.0 0.0 2.000 0.0 T.26 -2.13 -0.0035 0.0 4.000 -0.014 Vel = 1.17 T.26 0.0 0.862 1 UeI 11.0 4.000 9.385 to 150.0 0.0 12.000 0.0 H.7 -2.13 -0.0036 0.0 16.000 -0.057 Vel = 1.17 H.7 0.0 0.862 1 Utr 2.0 9.000 9.328 to 150.0 0.0 2.000 0.0 H.12 -2.13 -0.0035 0.0 11.000 -0.039 Vel = 1.17 H.12 13.10 0.862 1 Utr 2.0 2.000 9.289 K Factor = 4.30 to 150.0 0.0 2.000 0.0 T.33 10.97 0.0738 0.0 4.000 0.295 Vel = 6.03 T.33 -3.86 0.862 1 Utb 17.0 1.000 9.584 to 150.0 0.0 14.000 0.0 T.35 7.11 0.0331 0.0 15.000 0.496 Vel = 3.91 T.35 0.0 0.862 1 UeI 11.0 14.000 10.080 to 150.0 1 Utb 17.0 26.000 3.465 T.36 7.11 0.0331 0.0 40.000 1.322 Vel = 3.91 T.36 6.82 0.862 1 Utr 2.0 2.000 14.867 to 150.0 0.0 2.000 0.0 T.32 13.93 0.1148 0.0 4.000 0.459 Vel = 7.66 0.0 13.93 15.326 K Factor = 3.56 T.29 3.14 0.862 1 Utr 2.0 8.000 9.546 to 150.0 0.0 2.000 0.0 H.13 3.14 0.0073 0.0 10.000 0.073 Vel = 1.73 H.13 0.0 0.862 1 Utr 2.0 7.000 9.619 to 150.0 0.0 2.000 0.0 H.16 3.14 0.0073 0.0 9.000 0.066 Vel = 1.73 H.16 0.0 0.862 1 Utr 2.0 8.000 9.685 to 150.0 0.0 2.000 0.0 T.39 3.14 0.0073 0.0 10.000 0.073 Vel = 1.73 T.39 0.0 0.862 1 Utr 2.0 5.000 9.758 to 150.0 0.0 2.000 0.0 H.19 3.14 0.0073 0.0 7.000 0.051 Vel = 1.73 H.19 0.0 0.862 1 Utr 2.0 6.000 9.809 to 150.0 0.0 2.000 0.0 T.45 3.14 0.0072 0.0 8.000 0.058 Vel = 1.73 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A: Pex Design Services, Inc. -EP TL INVESTMENT GROUP LOT 2 - Two Head Calculation (H.9 & H.12) Page 8 Date 11/19/2012 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Notes ****** T.45 0.90 0.862 1 Uel 11.0 2.000 9.867 to 150.0 1 Utb 17.0 26.000 0.0 T.44 4.04 0.0116 0.0 28.000 0.326 Vel = 2.22 T.44 0.0 0.862 1 Utb 17.0 11.000 10.193 to 150.0 0.0 14.000 3.465 T.42 4.04 0.0116 0.0 25.000 0.291 Vel = 2.22 T.42 2.78 0.862 1 Utr 2.0 9.000 13.949 to 150.0 0.0 2.000 0.0 H.18 6.82 0.0305 0.0 11.000 0.336 Vel = 3.75 H.18 0.0 0.862 1 Uel 11.0 7.000 14.285 to 150.0 0.0 12.000 0.0 T.36 6.82 0.0306 0.0 19.000 0.582 Vel = 3.75 0.0 6.82 14.867 K Factor = 1.77 T.33 3.87 0.862 1 Utr 2.0 5.000 9.584 to 150.0 0.0 2.000 0.0 T.34 3.87 0.0107 0.0 7.000 0.075 Vel = 2.13 T.34 0.0 0.862 1 Utr 2.0 6.000 9.659 to 150.0 0.0 2.000 0.0 H.14 3.87 0.0107 0.0 8.000 0.086 Vel = 2.13 H.14 0.0 0.862 1 Utr 2.0 8.000 9.745 to 150.0 0.0 2.000 0.0 T.41 3.87 0.0107 0.0 10.000 0.107 Vel = 2.13 T.41 -0.90 0.862 1 Utb 17.0 3.000 9.852 to 150.0 0.0 14.000 0.0 T.40 2.97 0.0066 0.0 17.000 0.112 Vel = 1.63 T.40 0.0 0.862 1 Utb 17.0 17.000 9.964 to 150.0 1 UeI 11.0 26.000 3.465 T.37 2.97 0.0065 0.0 43.000 0.281 Vel = 1.63 T.37 -0.19 0.862 1 Utr 2.0 6.000 13.710 to 150.0 0.0 2.000 0.0 T.38 2.78 0.0059 0.0 8.000 0.047 Vel = 1.53 T.38 0.0 0.862 1 Utr 2.0 2.000 13.757 to 150.0 0.0 2.000 0.0 H.17 2.78 0.0058 0.0 4.000 0.023 Vel = 1.53 H.17 0.0 0.862 1 Utr 2.0 11.000 13.780 to 150.0 0.0 2.000 0.0 H.21 2.78 0.0058 0.0 13.000 0.076 Vel = 1.53 H.21 0.0 0.862 0.0 16.000 13.856 to 150.0 0.0 0.0 0.0 T.42 2.78 0.0058 0.0 16.000 0.093 Vel = 1.53 0.0 2.78 13.949 K Factor = 0.74 T.41 0.90 0.862 1 UeI 11.0 7.000 9.852 to 150.0 0.0 12.000 0.0 H.20 0.9 0.0007 0.0 19.000 0.014 Vel = 0.49 H.20 0.0 0.862 0.0 2.000 9.866 to 150.0 0.0 0.0 0.0 T.45 0.9 0.0005 0.0 2.000 0.001 Vel = 0.49 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A.-Pzxbesign Services, Inc. -EP • TL INVESTMENT GROUP LOT 2 - Two Head Calculation (H.9 & H.12) Page 9 Date 11/19/2012 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Notes ****** 0.0 0.90 9.867 K Factor = 0.29 T.37 0.19 0.862 1 Utr 2.0 5.000 13.710 to 150.0 0.0 2.000 0.0 H.15 0.19 0.0001 0.0 7.000 0.001 Vel = 0.10 H.15 0.0 0.862 1 Utr 2.0 23.000 13.711 to 150.0 0.0 2.000 0.0 H.4 0.19 0.0 0.0 25.000 0.001 Vel = 0.10 H.4 0.0 0.862 1 UeI 11.0 8.000 13.712 to 150.0 0.0 12.000 0.0 T.23 0.19 0.0 0.0 20.000 0.0 Vel = 0.10 0.0 0.19 13.712 K Factor = 0.05 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 5UPPI-Y STATIC P51: 70 n I:E5112UAt P51: 65 PLOW GPM: 500 50' OF I" POLY FROM 11-F Mgo.) TO 5.1— I" METER 12' OE 1" COPPER FROM 11-E 5111 n�1 AIL N.1{5 1 HEAP 2 -Min MOST 1FAn # H.6 H,9 & N,12 -hV AU.ICAU.Y I:FMO1E H AI25 GPM P551, 18 26 RI—Q112 AT 511:EFf 4195 50.52 0 IFCI3-16 0 I?FC4O-I8 O VK -160-200 19 RELIABLE Model RFC451:FC45 Concealed Pendent Sprinkler 155P°, '/ 8" Orifice, Maximum Spacing 16'x16' Sprinkler head demand: 13 qpm @ 9,14 RELIAC3LE Model RPC43RPC4' Concealed Pendent Sprinkler I55P°, 5/ 8H Orifice, Maximum Spacing 18'x18' Sprinkler head demand: 18 qpm @ 17.52 5EE S,I3MITTAL IPPA Ian 13151 ANa5 FROM HEA1 50UIU5 1 -EAT SOURCE ORDINARY TEMP IN. INTEEMEVIATF TEMP IN, 5112E OF PREPLACE 56" 12" FRONT OF FIREPLACE 60" 36" W0012 I3URNING STOVE 42" 12" KITCI-N pANa 18" 9" WALL OVEN 18" 9" HOf Alp P1-UE5 18" 9" UNIN5LLA1En NEAT DUCTS 18" 9" UNINSULA1Eb HOT WATER PIPE5 12" 6" 5112E OE N01" All:12IPFUSER 24" 12" FRONT 0' N01' Alp PIPPUSER 56" 18" NOT WATER HEAftR 6" S" FURNACE 6" 3" OW -250W LIGI.1" FIXTURE 6" 3" 250W -499W UGNr PIXTU:E 12" 6" 1 P?ELIM. & CON51{ 2 .. 4 11-19-12 N0. MU1.11-Pat PO5TOW 5WI1tH I1k51-A.L-ATION N.1".5. \0 1 1 C 5 � 111 90 2�61'\)�� �H3OW5 1AC1'0If 3 I \1'0 CAXULA11Ok FOF PIPM \':II\G AffICi 6.5.3 A warning sign, with minimum 1/4 inch letters, shall be affixed adjacent to the main shutoff valve and shall state the following: WARNING: The water system for this home supplies fire sprinklers that require certain flows and pressures to fight a fire. Devices that restrict the flow or decrease the pressure or automatically shut off the water to the fire sprinkler system, such as water softeners, filtration systems, and automatic shut-off valves, shall not be added to this system without a review of the fire sprinkler system by a fire protection specialist. Do not remove this sign. 11-15 5LGGF51F12 LAYOUT 15 13A5P13 UPON INPOWA11ON PPOVInFn 6Y O11-EP5, CHANGES IN CONSTRUCTION OR F- L17 CONn1110N5 MAY OCCLR WHICH MAY REQUIRE CHANGES T0 11 -E LAYOUT, IT 15 115PON511311-11Y 11- INSTA11- P TO NOTIFY APEX t7 51GN 56:VICES 0' SUCH CHANGE5, CON\C1101\5 50501X0, S.G. 50613 SLGD C01.0r/ I.IN1 YPI.6Nt7 [31 -UF LINES- ftFt2 TO PIX11.F5'(13Af1-, 5-0MR, FTC.) GREEN LINES= IN1 Ck;LCVCL CONNECTIONS, BLACK LINES= 5 INKLFp NEAP' TO SPRINKLER NEAP, -I/2"PIPE SIZE 3/ 4" PIPE SIZE - I" PIPE 51ZE I I / 4" PIPE 5lZE 2" PIPE 51ZE 3050 FIX 50501X0 3050 FIX EGRESS ice.+ E i.D 1 y r3 12' X11' (n 0 SOAK TUB 31-41 3' X 5' SHOWER ITC0-16 1'-6° 2'-10° SOCA 2 0 X 0 0 2460 X tl LINEN CLOSET 5065 BY-PASS 6'-0° 3 3'-0° 20 MIN. RATED D 1- 'ARDUJQOD 1- r E. ID RM '4 14' X 10' CARPET s -i FLOW swircH 1:l5p A55W31.Y DN 16R GARAGE SLAB ON GRADE \ i;` E PRESSUF A_ ,f To ExrERlo L C� XPzttl BANK. 2'-S'— ISEDI M r2 12' XII' 2 HALL 12' HIGH 0 FIX 1'-10° OPF4FC4 TO BELOW -PROVIDE ONE LAYER GWB TYPE °X° AT -C-EILINES e0MHIoN-U}ITH-WABfTABL-E-AREA S- -WI-iERE THE SETARATION IS A FLOOR - CEILING ASSEMBLY, CLAD ALL SUPPORT COLUMNS, BEAt`15 AND WALLS WITH ONE LAYER 1/2° GWB. -THE GARAGE SI -TALL BE SEPARATED FROM THE RESIDENCE AND ATTIC AREA WITH NO LESS THAN viz' (xWB ON THE GARAGE SIDE. WALL LINE ABOVE H 405 XO EGRESS 3030 FIX Gx) 1/4"-T-0" 0 0 0 \ GSA .,011:1/) Vr") 16010 OI -1D SLAB ftOO taj. 0 Without Comments As Noted in Red 0 Per The Attached Letter =, glans have be n -cion 6urc Eu fry: 'Q no t. ri r eview d h `file Tukwila Eire current City •to .-'.riors and .r;c'mi,., f,; of adopted for the designer. r::wings after ,wire a s+,t approval. and Inspection by I t:w i J . Ce micgll u. " c44-+46 Mi tL tuork> ue k.- S` Y i� � ott4c„ 1. '!~ 14i AK) rftttltwa. Y- Rod Cbvckel) Jc- rev -1J. TUKWIL A EIRE DEPARTMENT Please cell 205-575.4107 and give this Fire Permit -No. �..61e1 and exact address for shut- down or restoration approval,, 6" ALARM 1"0LOCA.301\ A122155 55 5I 12 O 31,111.11\G I/ 411 1,011 (PROJECT #: 121119-02 ALLIANCE 112#: DEsiGN sot '° FR 5 INKI.�f? 10751 47th PI W Mukdteo, WA 98215 PH: 425-495-9680 PAX: 425-495-9717 5ALE5 IV: P 5112 NTIAU FIRE PRO1 CTION 5Y51hM 11J3E TYPE: I / 2 - 3/ 4" - I" AQUAPEX SPRINKLER INFORMATION # OF 1-EAP25 TNI5 - 21 # OF NtAr2511-15 JOI3 - 21 5TA11C P2E551, 15= 70 ON'y FOR 0 O�`G O ii/ P d '/, S`a�e Certlfieek ��oY stephaV Mstrie30• Fa eY 8 lr .,nL��L_ �P -t‘IVY dye` o do eTt `c �t'` 'e (i0 D N O \ \ \ CO IC:*) \ \ \CO v \----- t6) \ 1 P?ELIM. & CON51{ 2 .. 4 11-19-12 N0. I:BVI50N/ 155LE 12Th (PROJECT #: 121119-02 ALLIANCE 112#: COMPANY: 50UNPVIEW PLUMPING CONTACT: JO5-1 TP.EMMEL CONTACT PHONE 4*; 425-760-4240 SCALE: I/ 4I I I 1-01 12E51GNEn 13Y: KAREN 13A13L3 C1-ECKE1213Y: 511;PHANIE FAI-Y VERIFICATION #: 109-04-21 0..,J 00 A #2-33 Ul~ 19 2012 o,s-b 1 UIOWILA FIRE