FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
Site Address: LI ,S . y 6 ri S�
Tenant Name: O t (Le
King Co. Assessor's Tax No.:
Suite Number: Floor:
New Tenant? ❑ - Yes ❑ - No
Property Owner's Name: L‘ ‘'�
Mailing Address:
CONTACT PERSON -if there are questions about the submittal.
Name: -Pe A e l -4-e 1A-04./
Company Name: e ri 1 e p✓ O 4.( `3'i
City
State Zip
Day Telephone: 1425 ,e/ 7—S 72
Mailing Address: n• 3 tk t 3 a D / wtet `i'q t
City State Zip
E-mail Address: We 40? o'C�vO r� a% 4* 4: L. ( 0 "A4 Fax Number:
Contractor's City of Tukwila
NICET III number: r Business License number:
Total number of new/relocated devices or sprinkler heads: I
Valuation of Project (contractor's bid price): $ 56 D
Scope of Work (please provide detailed information): T-4)544 ( +✓� /� �' k�r� S� Sle
10 rki s 4&` ‘)S 5‘,04c--4,1 4JPW r -fi u per A/1104 v WA(
9i( olcvelY
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature: .4/t. � Date: f3-'2--1
Print Name: VPT l N.(1 -to& Day Telephone: LZ S in 7-5 741
Plan Permit App.doe 8/22/14 TFD FP Form 8
4a"W4v
SITE LOCATION
Site Address:
Tenant Name:
CITY OF TUKWILA
FIRE MARSHAL'S OFFICE
206-575-4407
FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
1-18 13 so. /401 sr
V< <J & (ctk, lR a o C c s
King Co. Assessor's Tax No.:
Suite Number: Floor:
New Tenant? ❑ - Yes ❑ - No
Property Owner's Name:
Mailing Address:
City State Zip
CONTACT PERSON -if there are questions about the submittal.
Name: Pe4e N e (fo •J
Company Name:
e (+ON J� Pt.✓�"��c_4-to'J
Day Telephone: 112C 17- 7 5 7S
Mailing Address: 0 X VZ 0 vite ,,r2 c7 6 -tie S L u 9 b 1 t
f City State Zip
E-mail Address: i-te «OV F•dc e �(�LOV , cm/v-1 Fax Number:
Contractor's City of Tukwila Business License number:
Total number of new/relocated devices or sprinkler
r heads: / 1
Valuation of Project (contractor's bid price): $ L4) (63
Scope of Work (please provide detailed information): 7A)51e (( xs fe S -t +c Pev A-) (34
54C, ki acAl ctco
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING OW ERROR AUTHORIZED AGENT:
Signature: -/./ trtDate: 6—/(}-4 C
Print Name: ?2-te 14e v Day Telephone: 2 5 1 7 -5 ' 6 (
Plan Permit App.doc 8/22/14 TFD FP Form 8
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
-S-!WZ
v7 -- 0 2t2_
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
206-575-4407
Project: I+'esi
omp
Sprinklers:
n_: /
Type of Inspection:
Address: /��
`7
Suite #: /
7
Contact Person:
Special Instructions:
Occupancy Type:
Phone No.:
Approved per applicable codes.
nCorrections required prior to approval.
COMMENTS:
X-041
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
inspect4
. - fl9
Date: l%/, ?
IHrs.:
/.-
v
$100.00 REINSPECTION FEE REQUIRED.. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word/Inspection Record Form.Doc
3/14/14
T.F.D. Form F.P. 113
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
206-575-4407
Project: /Zit 4.---‹
•
Sprinklers:
Ty f Ins ion: C^�
r
Address:4� (�
Suite #:
>` ��-A�j
f'
.7-
5
Contact Person:
Special Instructions:
Permits:
13vac.-ems
Phone No.:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Sprinklers:
Date: rhTlcl
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
13vac.-ems
-6v6I
ly v2, f-teM05 6707—
M f
D /3 5 el,(
/ 4- y
/Ai 36 5,.,6.
,
c
-v
1
o lc
g ec) cviv2-ifr
-
T
'17'-'6Z &1-
-( f2 -01T-'7
Needs Shift Inspection:
Sprinklers:
Date: rhTlcl
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector:
i- -
Date: rhTlcl
Hrs.:
f
/"' l
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. CaII to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word/Inspection Record Form.Doc
3/14/14
T.F.D. Form F.P. 113
Z
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
"'›b -oozy
('0-s- 13k5
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
206-575-4407
Project;-
C -1,4%.(c--)7,.;_
Type of In�pectionn
'C-06%-st:.
Address:
Suite #: V5/3
S /y6
Contact Person:
Special Instructions:
Phone No.:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector:
����
Date: 6/2.S/
Hrs.: / 0
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip
Word/Inspection Record Form.Doc
3/14/14
T.F.D. Form F.P. 113
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
206-575-4407
Proje
'�
Sprinklers:
`�
Type of Inspection:
s r° Cov- '
Addr s: f ? 13
Suite #:
5
l' 61--
Contact Person:
Special Instructions:
Phone No.:
improved per applicable codes.
Corrections required prior to approval.
COMMENTS:
-ett7-; _off
TSL `To Cay-tl-
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector:
sy-z_
Date: 4(94//6„
Hrs.:
/
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word/Inspection Record Form.Doc
3/14/14
T.F.D. Form F.P. 113
City of Tukwila
FILE
John W. Rants, Mayor
Fire Department Thomas P. Keefe, Fire Chief
September 16, 1999
Fire Department Review
Control #D99-0327
Re: Brian Gadzuk residence - 4813 South 146th Street
Dear Sir:
The attached set of building plans have been reviewed by
The Fire Prevention Bureau and are acceptable with the
following concerns:
1. An approved automatic fire sprinkler extinguishing
system is required for this project. (City Ordinance
#1742)
All sprinkler system plans, calculations and the
contractors Materials and Test Certificates submitted
to The Tukwila Fire Prevention Bureau must be stamped
with the appropriate level of competency seal. (WAC
212-80)
2. Every building shall be accessible to Fire Department
apparatus by way of access roadways with all-weather
driving surface of not less than 20' wide and 13'6"
vertical clearance. Access roads in excess of 150' shall
be provided with an approved turn -around area. Access
shall be within 150' of all portions of the buildings.
(City Ordinance #1846)
The fire department turnaround shall be labeled as a
fire lane.
"FIRE LANE - NO PARKING" areas were declared at your
complex because of less than minimum clearances for
fire department vehicle access. These areas are in
need of re-signing or repainting per City Ordinance
#1846 and Uniform Fire Code Section 10.206 as amended.
Fire apparatus access roads "fire lanes" shall be
identified by painting the curb yellow and a four inch
wide line and block letters 18 inches painted in the
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439
City of Tukwila
Fire Department
Page number 2
John W. Rants, Mayor
Thomas P. Keefe, Fire Chief
lane, at fifty foot intervals, stating, "FIRE LANE NO
PARKING", color to be bright yellow, or by the posting
of signs stating, "FIRE LANE NO PARKING", and painting
the curb. Signs shall be posted on or immediately
next to the curb line or on the building. Signs shall
be twelve inches by eighteen inches and shall have
letters and background of contrasting color, readily
readable from at least a fifty foot distance. Signs
shall be spaced not further than fifty feet apart nor
shall they be more than four feet from the ground.
(City Ordinance #1846)
3. Your street address must be conspicuously posted on
the building and shall be plainly visible and legible from
the street. (UFC 901.4.4)
Any overlooked hazardous condition and/or violation of the
adopted Fire or Building Codes does not imply approval of
such condition or violation.
Yours truly,
The Tukwila Fire Prevention Bureau
cc: TFD file
ncd
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439
F' L E JAN 1 8 2001
City of Tukwila John W. Rants, Mayor
Fire Department Thomas P. Keefe, Fine Chief
TUKWILA FIRE DEPARTMENT
FINAL APPROVAL FORM
Project Name
Permit No. n `03 ).2
Address L/)/3 3 /L/C )1- Suite #
Retain current inspection schedule
Needs shift inspection
Approved without correction notice
Approved with correction notice issued
Sprinklers:
Fire Alarm:
Hood & Duct:
Halon:
Monitor:
Pre -Fire:
Permits:
Authorize Signature Date
FINALAPP.FRM T.F.D. Form F.P. 85
Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 5754439
Sheet 1
Helton Fire
Date 03/02/18
Job: ROARES11
PROJECT INFORMATION
Job Roa Res
4813 So 146th St Tukwila WA
Occupancy Light Hazard
Area per Sprinkler 256 sq ft 16X16 Coverage
Sprinklers Tyco Lf -2 Concealled 4.9K
Number of Sprinklers Calculated: 2 heads
Authority having Jurisdiction_ _ Tukwila Fire Dept
System type_ _ Wet
Water Supply 140.00 psi Static, 130.00 psi Residual @ 26.0
gpm
Demand
CALCULATION SUMMARY
19.67 psi @ 26.0 gpm @ B.O.R.
25.72 psi @ 26.0 gpm @ Supply
130.00 psi available @ 26.0 gpm
Below curve by 104.28 psi
PROGRAM: 'HydroCalc' by Micro Space Systems
www.microspacesystems.com
r
WATIONOTON STATE
FIRE rRO�TECATION� LECOMPETENCY
STEMS
Pete Helton
9390-0601-A Level 1
Helton Fire Pr.,tection
H TOFP965NC
ILMI
vvrng
• aIco
co
as • 3 a
a 0 0 ID
v O
• cc'3
• 11 11
2JI(m
Q 0 • IV v
C
8 - 0.0
o g.�
v rn9
'"• v O 0
• 0 '
ta co
0033
0 c
11i
O
W
O
O
6T
O
T
0
O
co
O
0
8
O
N
O
O
O
O)
O
1
Pressure (PSI)
O
0
0
O
Sheet 2
0
0
m
to
Roa Res Sheet 3
Helton Fire
Description of Fitting abbreviations
Code Description
PE Plastic 90 degree Elbow
PTR Plastic Tee flow thru run
BKF Backflow preventor
MTR Meter Loss
Description of Other abbreviations
Code Description
DR Drop
BL Branch Line
PT Total pressure
PE Pressure loss due to elevation changes
PF Pressure loss due to friction
".5 Raised to the power of .5 (Square Root)
L Actual pipe length
F Fitting equivalent pipe length
T Total pipe length
ROARES11 03/02/18 11:02am Sheet 4
Helton Fire
Srinkler Systems Hydraulic Flow Calculations
Roa Res
4813 So 146th St Tukwila WA
Raw data previous to any calculations
No. Code Diam Length Kfacl
1 DR1 1.109
2 DR2 1.109
3 BL1 1.109
4 RI1 1.109
5 UG1 1.602
6 UG2 1.109
Kfac2 Press Elev Hose HW Vel Fittings
0.50 4.9 7.000 -0.500 0.0 150
0.50 4.9 7.000 -0.500 0.0 150
32.00 DR1 DR2 0.000 -0.500 0.0 150
6.00 BL1 -4 0.000 -0.500 0.0 150
160.00 RI1 0.000 -0.500 0.0 150
0.00 UG1 -3 0.000 -0.500 0.0 150
32 1PE
32 1PE,1PTR
32 4PE,1PTR
32 2PE,4PTR,1BKF
32 4PE
32 1MTR
ROARES11 03/02/18 11:02am Sheet 5
Helton Fire
Srinkler Systems Hydraulic Flow Calculations
Roa Res
4813 So 146th St Tukwila WA
Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel
No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes
Drop 1 C = 150
L 0.5 PT 7.00 1
13.0=4.90(7.00)^.5 F 7.0 PE -0.22 (EL= -0.5 ft)
1 13.0 1.109 1PE T 7.5 0.02945 PF 0.22 4.3
PT 7.00 3 B1 Jct
K -factor for drop 1 = 13.0/(7.00)".5 = 4.91
Drop 2 C = 150
L 0.5 PT 7.00 2
13.0=4.90(7.00)1.5 F 8.0 PE -0.22 (EL= -0.5 ft)
2 13.0 1.109 1PE 1PTR T 8.5 0.02945 PF 0.25 4.3
PT 7.03 3 B1 Jct
K -factor for drop 2 = 13.0/(7.03)^.5 = 4.90
ROARES11 03/02/18 11:02am Sheet 6
Helton Fire
Srinkler Systems Hydraulic Flow Calculations
Roa Res
4813 So 146th St Tukwila WA
Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel
No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps)
Branchline No. 1
K=9.81=4.91+4.90 L 32.0 PT 7.03 3
26.0=9.81(7.03)".5 F 29.0 PE -0.22
3 26.0 1.109 4PE 1PTR T 61.0 0.10688 PF 6.52
PT 13.33 4
K -factor for branchline no. 1 = 26.0/(13.33)^.5 = 7.12
Notes
C = 150
DR1 + DR2
(EL= -0.5 ft)
8.6
Top of Riser
ROARES11 03/02/18 11:02am Sheet 7
Helton Fire
Srinkler Systems Hydraulic Flow Calculations
Roa Res
4813 So 146th St Tukwila WA
Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel
No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps)
Notes
Riser C = 150
L 6.0 PT 13.33 4 BL1
F 18.0 PE -0.22 (EL= -0.5 ft)
4 26.0 1.109 2PE 4PTR T 24.0 0.10670 PF 6.56 8.6 1BKF = 4.00#
1BKF PT 19.67 5 B.O.R.
Under ground
5 26.0 1.602
C = 150
L 160.0 PT 19.67 5 B.O.R.
F 36.0 PE -0.22 (EL= -0.5 ft)
4PE T 196.0 0.01779 PF 3.49 4.1
PT 22.94 6
Under ground C = 150
= L 0.0 PT 22.94 6 B.O.R.
F 0.0 PE -0.22 (EL= -0.5 ft)
6 26.0 1.109 1MTR T 0.0 0.00000 PF 3.00 8.6 1MTR = 3.00#
PT 25.72 7 Supply Jct
Available flow at 25.72 psi is 97.0 gpm which is 71.0 gpm from curve.
Supply pressure available with 26.0 gpm flowing is 130.00 psi,
thus system requirement is 104.28 psi below supply curve. (80.2%)
ROARES11 03/02/18 11:02am Sheet 8
Supply Analysis
Node at Static Residual Available Total Required
Source Pressure Pressure Flow Pressure Demand Pressure
7 140.00 130.00 26.0 130.00 26.0 25.72
Node Analysis
Elevation Node Type Pressure Discharge
Node (ft) K -Value Source (psi) (gpm)
_
Notes
1 -2.50 Orif= 4.90
2 -2.50 Orif= 4.90
3 -2.00
4 -1.50
5 -1.00
6 -0.50
7.00
7.00
7.03
13.33
19.67
22.94
13.0
13.0
ROARES11 03/02/18 11:02am
Nodel Elevi
Pipe (ft)
Node2 Elev2
Pipe Information
Kfactor Qadd Nominal Fittings
Hose ID
Qtot Actual Length
Sheet 9
L (ft) Cfac Total Pt
F (ft) Vel Elev Pe
T (ft) Psi/Ft Fric Pf Notes
1 -2.50 4.90
1
3 -2.00
13.0 1" 1PE
13.0 1.109 7.0
L 0.5 150 Pt 7.00
F 7.0 4.3 Pe -0.22
T 7.5 0.0295 Pf 0.22 DR1:K=4.91
2
2 -2.50 4.90
3 -2.00
13.0 1" 1PE 1PTR
13.0 1.109 8.0
L 0.5 150 Pt 7.00
F 8.0 4.3 Pe -0.22
T 8.5 0.0295 Pf 0.25 DR2:K=4.90
3
3 -2.00 9.81
4 -1.50
[26.0] 1" 4PE 1PTR
26.0 1.109 29.0
L 32.0 150 Pt 7.03 DR1 + DR2
F 29.0 8.6 Pe -0.22
T 61.0 0.1069 Pf 6.52 BL1:K=7.12
4
4 -1.50 7.12
5 -1.00
[26.0] 1" 2PE 4PTR
1BKF
26.0 1.109 18.0
L 6.0 150 Pt 13.33 Top of Riser
F 18.0 8.6 Pe -0.22 1BKF = 4.00#
T 24.0 0.1067 Pf 6.56
5
5 -1.00
6 -0.50
1 1/2" 4PE
26.0 1.602 36.0
L 160.0 150 Pt 19.67
F 36.0 4.1 Pe -0.22
T 196.0 0.0178 Pf 3.49
6
6 -0.50
7 0.00
1"
26.0 1.109
L 0.0 150 Pt 22.94
F 0.0 8.6 Pe -0.22 1MTR = 3.00#
T 0.0 0.1067 Pf 3.00 Supply
Helton Fire
PROJECT INFORMATION
Job Vinayak Rao Res
4813 So 146th ST Tukwila WA
Occupancy
Area per Sprinkler
Sprinklers
Number of Sprinklers Calculated:
-+t
Sheet 1
Date 06/03/16
Job: RAORES1
Light Hazard
256 sq ft
Tyco Lf -2 Concealled
2 heads
4.9K 16X16 coverag
Authority having Jurisdiction_ _ Tukwila Fire Dept
System type Wet
Water Supply 65.00 psi Static, 60.00 psi Residual @ 26.0
gpm
Demand
CALCULATION SUMMARY
26.76 psi @ 26.0 gpm @ B.O.R.
33.89 psi @ 26.0 gpm @ Supply
60.00 psi available @ 26.0 gpm
Below curve by 26.11 psi
PROGRAM: 'HydroCalc' by Micro Space Systems
www.microspacesystems.com
r
WASHINGTON STATE
FIRE CERTIFICATE OF
SYSTEMS
Pete Helton
9390-0601-A Levet 1
Helton Fire Protection
HEOFP965NC
(1-14
`SIgnature Date
s
7
N
O
0
0
0
rn
0
T_
2
0
O
03
O
■■
3 co St
a3 0 a
yi 0) 0)a a)
0iD
O c 11 11
Z cm w ° o
mo°�
0) O.
-oe rnrn
IV O O
. 0 0] co
41 co 3
r.
co 40
[0
Pressure (PSI) Sheet 2
Y9i N Pegs tiewwnS;sel hioW
Vinayak Rao Res Sheet 3
Helton Fire
Description of Fitting abbreviations
Code Description
PE Plastic 90 degree Elbow
PTR Plastic Tee flow thru run
BKF Backflow preventor
MTR Meter Loss
Description of Other abbreviations
Code Description
DR Drop
BL Branch Line
PT Total pressure
PE Pressure loss due to elevation changes
PF Pressure loss due to friction
^.5 Raised to the power of .5 (Square Root)
L Actual pipe length
F Fitting equivalent pipe length
T Total pipe length
RAORES1 06/03/16 8:55am Sheet 4
Helton Fire
Srinkler Systems Hydraulic Flow Calculations
Vinayak Rao Res
4813 So 146th ST Tukwila WA
Raw data previous to any calculations
No. Code Diam Length Kfacl
1 DR1 1.109
2 DR2 1.109
3 BL1 1.109
4 RI1 1.109
5 UG1 1.602
6 UG2 1.109
0.50 4.9
0.50 4.9
71.00 DR1
6.00 BL1
140.00 RI1
4.00 UG1
Kfac2 Press Elev Hose HW Vel Fittings
7.000 -0.500 0.0 150
7.000 -0.500 0.0 150
DR2 0.000 -0.500 0.0 150
- 5 0.000 -0.500 0.0 150
0.000 -0.500 0.0 150
- 4 0.000 -0.500 0.0 150
32 1PE
32 1PE,1PTR
32 6PE,5PTR
32 2PE,4PTR,1BKF
32 4PE
32 1MTR
RAORES1 06/03/16 8:55am Sheet 5
Helton Fire
Srinkler Systems Hydraulic Flow Calculations
Vinayak Rao Res
4813 So 146th ST Tukwila WA
Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel
No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps) Notes
Drop 1 C = 150
L 0.5 PT 7.00 1
13.0=4.90(7.00)^.5 F 7.0 PE -0.22 (EL= -0.5 ft)
1 13.0 1.109 1PE T 7.5 0.02945 PF 0.22 4.3
PT 7.00 3 Bl Jct
K -factor for drop 1 = 13.0/(7.00)".5 = 4.91
Drop 2 C = 150
= L 0.5 PT 7.00 2
13.0=4.90(7.00)^.5 F 8.0 PE -0.22 (EL= -0.5 ft)
2 13.0 1.109 1PE 1PTR T 8.5 0.02945 PF 0.25 4.3
PT 7.03 3 B1 Jct
K -factor for drop 2 = 13.0/(7.03)^.5 = 4.90
RAORES1 06/03/16 8:55am Sheet 6
Helton Fire
Srinkler Systems Hydraulic Flow Calculations
Vinayak Rao Res
4813 So 146th ST Tukwila WA
Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel
No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps)
Branchline No. 1
K=9.81=4.91+4.90 L 71.0 PT 7.03 3
26.0=9.81(7.03)^.5 F 47.0 PE -0.22
3 26.0 1.109 6PE 5PTR T 118.0 0.10688 PF 12.61
PT 19.42 4
K -factor for branchline no. 1 = 26.0/(19.42)^.5 = 5.90
Notes
C = 150
DR1 + DR2
(EL= -0.5 ft)
8.6
Top of Riser
RAORES1 06/03/16 8:55am Sheet 7
Helton Fire
Srinkler Systems Hydraulic Flow Calculations
Vinayak Rao Res
4813 So 146th ST Tukwila WA
Pipe Flow Dia Fitting Length Fr Loss Press Hyd Vel
No (gpm) (inch) and Dev (ft) (psi/ft) (psi) Ref (fps)
Notes
Riser C = 150
L 6.0 PT 19.42 4 BL1
F 18.0 PE -0.22 (EL= -0.5 ft)
4 26.0 1.109 2PE 4PTR T 24.0 0.10670 PF 7.56 8.6 1BKF = 5.00#
1BKF PT 26.76 5 B.O.R.
Under ground
5 26.0 1.602
L 140.0 PT 26.76 5
F 36.0 PE -0.22
4PE T 176.0 0.01780 PF 3.13
PT 29.68 6
C = 150
B.O.R.
(EL= -0.5 ft)
4.1
Under ground C = 150
L 4.0 PT 29.68 6 B.O.R.
F 0.0 PE -0.22 (EL= -0.5 ft)
6 26.0 1.109 1MTR T 4.0 0.10674 PF 4.43 8.6 1MTR = 4.00#
PT 33.89 7 Supply Jct
Available flow at 33.89 psi is 69.8 gpm which is 43.8 gpm from curve.
Supply pressure available with 26.0 gpm flowing is 60.00 psi,
thus system requirement is 26.11 psi below supply curve. (43.5%)
RAORES1 06/03/16 8:55am Sheet 8
Supply Analysis
Node at Static Residual Available Total Required
Source Pressure Pressure Flow Pressure Demand Pressure
7 65.00 60.00 26.0 60.00 26.0 33.89
Node Analysis
Elevation Node Type Pressure Discharge
Node (ft) K -Value Source (psi) (gpm)
Notes
1 -2.50 Orif= 4.90
2 -2.50 Orif= 4.90
3 -2.00
4 -1.50
5 -1.00
6 -0.50
7 0.00
Supply
7.00
7.00
7.03
19.42
26.76
29.68
33.89
13.0
13.0
RAORES1 06/03/16 8:55am
Nodel Elevl
Pipe (ft)
Node2 Elev2
Pipe Information
Kfactor Qadd Nominal Fittings
Hose ID
Qtot Actual Length
Sheet 9
L (ft) Cfac Total Pt
F (ft) Vel Elev Pe
T (ft) Psi/Ft Fric Pf Notes
1 -2.50 4.90
1
3 -2.00
13.0 1" 1PE
13.0 1.109
__
L 0.5 150 Pt 7.00
F 7.0 4.3 Pe -0.22
7.0 T 7.5 0.0295 Pf 0.22 DR1:K=4.91
2
2 -2.50 4.90
3 -2.00
13.0 1" 1PE 1PTR
13.0 1.109 8.0
L 0.5 150 Pt 7.00
F 8.0 4.3 Pe -0.22
T 8.5 0.0295 Pf 0.25 DR2:K=4.90
3
3 -2.00 9.81
4 -1.50
[26.0] 1" 6PE 5PTR
26.0 1.109 47.0
L 71.0 150 Pt 7.03 DR1 + DR2
F 47.0 8.6 Pe -0.22
T 118.0 0.1069 Pf 12.61 BL1:K=5.90
4
4 -1.50 5.90
5 -1.00
[26.0] 1" 2PE 4PTR
1BKF
26.0 1.109 18.0
L 6.0 150 Pt 19.42 Top of Riser
F 18.0 8.6 Pe -0.22 1BKF = 5.00#
T 24.0 0.1067 Pf 7.56
5
5 -1.00
6 -0.50
1 1/2" 4PE
26.0 1.602 36.0
L 140.0 150 Pt 26.76
F 36.0 4.1 Pe -0.22
T 176.0 0.0178 Pf 3.13
6
6 -0.50
1"
7 0.00 26.0 1.109
L 4.0 150 Pt 29.68
F 0.0 8.6 Pe -0.22 1MTR = 4.00#
T 4.0 0.1067 Pf 4.43 Supply
LIFE SAFETY REQUIREMENTS
Stairs
Reference IRC R311.7
Minimum 36" clear width.
Maximum 7 3/4" rise.
Minimum 10" run.
Minimum 6'-8" head room.
Handrail 34"-38" above tread nosing.
Handrail grasping dimension 1-1/4" minimum - 2" maximum.
For winding stairs provide a minimum 10" tread at 12" from
the narrowest point.
Decks/Guardrails
Reference IRC R312
Guard (guardrail) required for walking surfaces 30" above
adjacent grade or floor below.
36" high required minimum.
4" maximum clear space between intermediate rails.
Smoke Detectors
Reference: IRC R314
Detectors shall be installed in accordance with the approved
manufacturer's instructions and in accordance with IRC
R314.
Must be powered by interconnected building wiring, and have
battery back-up in new construction and additions and
anywhere where the interior surfaces of the space are
removed or access for wiring is available through a crawl
space or attic.
May be battery -powered in alterations except when wiring
can be installed without removal of interior finishes.
Required in sleeping rooms, outside sleeping areas, and
other floors (including basements). Any alarm must be
dearly audible in all bedrooms.
Carbon Monoxide Alarms
Reference: IRC R315
For new construction, and for alterations, repairs and
additions to existing dwellings, that require a permit, an
approved carbon monoxide alarm shall be installed outside of
each separate sleeping area in the immediate vicinity of the
bedrooms in dwelling units.
In a building where a tenancy exists, the tenant shall maintain
the alarm as specified by the manufacturer, including
replacement of the batteries.
Single station carbon monoxide alarms shall be listed as
complying with UL 2034 and shall be installed in accordance
with this code and the manufacturer's installation instructions.
Emergency Escape & Rescue
Reference IRC R310
One window (or door) in basement and each bedroom must
meet these requirements:
5.7 sq. ft. minimum net clear open area (windows with
maximum sill height 44" above or below grade may have 5.0
sq. ft minimum net clear open area).
20" minimum clear open width.
24" minimum clear open height.
44" maximum sill height.
Window wells require minimum 3'x3' but must permit full
opening of window. Ladder escape okay.
Wall Key
New Wall
Existing Wall
Demo Wall
SD' SMOKE DETECTOR
CD CO/SMOKE DETECTOR
EXHAUST FAN
' '--- 50 CFM (min.) UNO
NEW HOSE BIB -
VERIFY LOCATION w/OWNER
,B.
without Comments
As Noted in Red
Per The Attached Letter
These plans have :been reviewed by The Tukwila Fire,;
prevention; Bureau:, for conformanr.F with current City;
standards Acceptant e i subjee rr., ea-rors and
ornlsslons which dpi" riot authorl,. ,y"olr�tions of adopted
ndards and ord(r�ancQs Thc. .. ' punslhllicy for"the
adequacy of design rests otaliv'witn d :esigner,
A di ions, deletions czr aYevlsions to rr�ese drawings after
thls date wiii void tries•,acceptance and will. require a
resubmlttai of revised drawings for suosequent approval:
Finalacceptance is subject to fleld test and inspection by
' The.Tukwile Fire Prevention Bureau,
Date: 3. �.9 i By: 61.1
3104 Western Avenue,...
Suite 107
Seattle WA 98121
206.204.0490
www.motion-space.com
NEW
ELECTRICAL
METER
Crawl Space Ventilation Code
Reference: R408.1, R408.2
The under -floor space between the bottom of the floor joists and the earth
under any building (except space occupied by a basement) shall have
ventilation openings through foundation walls or exterior walls. The minimum
net area of ventilation openings shall not be less that 1 square foot for each
300 square feet of under -floor area. One ventilating opening shall be within 3
feet of each corner of the building, except one side of the building shall be
permitted to have no ventilation openings. In addition, a ground cover that
meets the requirements of 502.1.6.7 of the WSEC (Chapter 51-11 WAC)
shall be installed. Ventilation openings shall be covered for their height and
width with any of the following materials provided that the least dimension of
the covering shall not exceed 1/4 inch.
1. Perforated sheet metal plates not less than 0 070 inch thick
2.
3.
4.
5.
6.
Expanded sheet metal plates not less than0.047 inch thick.
Cast-iron grill or grating.
Extruded load-bearing brick vents.
Hardware cloth of 0.035 inch wire or heavier.
Corrosion -resistant wire mesh, with the least dimension being 1/8 inch.
Crawl Space Ventilation Calculations:
Required Area: 275 SF x 1/300 = 0.92 sf = 132 SQ IN.
Provided Area: (4) 128 SQ IN vents = 512 SQ IN.
GARAGE FLOOR SLAB @ MAX. 7 1/2"
BLW. MUDROOM FINISH FLOOR
1/2" TYPE 'X' GWB ON GARAGE WALLS
5/8" TYPE 'X' GWB ON GARAGE CEILING
RELOCATE (E) HB
NEW GAS METER, MAINTAIN
REQUIRED CLEARANCES
• LOCATE DOOR ,
AS REQUIRED`
.:FOR EXISTING
EQUIPMENT IN
`UTILITY ROOM•
5. KINILA FIRE DEPA RTGi' N i
n`1.. �+,
,111.:,ti�'hut-
: cr.lc: . nns, Dn'approval.
REMOVE ()
',GAS METER:
1 LJ 1
NEW FLOOR.
DRAIN, INSTALL
TRAP PRIMER
\ (e) elec. (e) hot water
panels xS� macc,,,
(E) Utility SpritikI
combined smoke
and CO detector
Cys,
araaassupseamosrrssrem
(E) Playroom -
Convert to
Mudroom
Date Revision Description
(E) Parlor
51cs:54-oN '1 i sem:
erN Main Level Floor Plan
1/4" 1-0
oo
e7 U
Z
Ham,
00-1P4 4�
PAID
—2.01
TUKWILA FI
ec..S�'
Exhaust Systems
REFERENCE RESIDENTIAL CODE CHAPTER 15 (2015)
SECTION M1501 GENERAL
The air removed by every mechanical exhaust system shall be discharged to the
outdoors in accordance with Section M1506.2. Air shall not be exhausted into an
attic, soffit, ridge vent or crawl space.
Exception: Whole -house ventilation -type attic fans that discharge into the attic
space of dwelling units having private attics shall be permitted.
Exhaust ducts are to be constructed of smooth bore noncombustible material and
are to be insulated as required by code.
See Chapter 15 for additional code requirements.
SECTION M1502 - CLOTHES DRYER EXHAUST
Ventilation duct for the dryer shall be 4" diameter metal and provided with a
backdraft damper concealed in construction. Install dryer and exhaust per dryer
manufacturer's instructions.
SECTION M1503 - RANGE HOODS
Exhaust hood systems capable of exhausting in excess of 400 CFM shall be
provided with makeup air at a rate approximately equal to the exhaust air rate. Such
makeup air systems shall be equipped with a means of closure and shall be
automatically controlled to start and operate simultaneously with the exhaust
system.
SECTION M1506 - EXHAUST DUCTS AND EXHAUST OPENINGS
Air exhaust openings shall terminate not less than 3 feet from property lines; 3
feet from operable and nonoperable openings into the building and 10 feet from
mechanical air intakes except where the opening is located 3 feet above the air
intake. Openings shall comply with Sections R303.5.2 and R303.6.
SECTION M1507 - MECHANICAL VENTILATION (M1507.4 Local exhaust)
Local exhaust shall be provided in each kitchen, bathroom, water closet, laundry
room, indoor swimming pool, spa, and other rooms where water vapor or cooking
odor is produced. Local exhaust systems shall be designed to have the capacity to
exhaust the minimum air flow rate determined in accordance with Table M1507.4:
Kitchens: 100 cfm intermittent or 25 cfm continuous.
Bathrooms -Toilet Rooms, laundry rooms, indoor swimming pools, spas:
Mechanical exhaust capacity of 50 cfm intermittent or 20 cfm continuous.
Exhaust fans providing local exhaust shall have a minimum fan flow rating not less
than 50 cfm at 0.25 inches water gauge for bathrooms, laundries, or similar rooms
and 100 cfm at 0.25 inches water gauge for kitchens.
Exception: Where a range hood or down draft exhaust fan is used to satisfy
the local exhaust requirements for kitchens, the range hood or down draft
exhaust shall not be less than 100 cfm at 0.10 inches water gauge.
M1507.4.2 Local exhaust controls. Local exhaust systems shall be controlled by
manual switches, dehumidistats, timers, or other approved means. Local exhaust
system controls shall be readily accessible.
SECTION M1507 - MECHANICAL VENTILATION (WHOLE HOUSE
VENTILATION)
(See 2015 Building Code for complete code section requirements)
M1507.3 Whole -house mechanical ventilation system. Whole -house mechanical •
ventilation systems shall be designed in accordance with Sections M1507.3.1
through M1507.3.7.3.
M1507.3.1 System design. Each dwelling unit or guestroom shall be equipped with
a ventilation system complying with Section M1507.3.4, M1507.3.5, M1507.3.6 or
M1507.3.7. Compliance is also permitted to be demonstrated through compliance
with the International Mechanical Code.
M1507.3.2 Control and operation.
1. Location of controls. Controls for all ventilation systems shall be readily
accessible by the occupant.
2. Instructions. Operating instructions for whole -house ventilation systems shall be
provided to the occupant by the installer of the system.
3. Local exhaust systems. Local exhaust systems shall be controlled by manual
switches, dehumidistats, timers, or other approved means.
4. Continuous whole -house ventilation systems. Continuous whole -house
ventilation systems shall operate continuously. Exhaust fans, forced -air system
fans, or supply fans shall be equipped with"fan on" as override controls. Controls
shall be capable of operating the ventilation system without energizing other
energy -consuming appliances. A label shall be affixed to the controls that reads
"Whole House Ventilation (see operating instructions)."
5. Intermittent whole -house ventilation systems. Intermittent whole -house ventilation
systems shall comply with the following:
5.1. They shall be capable of operating intermittently and continuously.
5.2. They shall have controls capable of operating the exhaust fans, forced -air
system fans, or supply fans without energizing other energy -consuming
appliances.
5.3. The ventilation rate shall be adjusted according to the exception in Section
M1507.3.3.
5.4. The system shall be designed so that it can operate automatically based
on the type of control timer installed.
5.5. The intermittent mechanical ventilation system shall operate at least one
hour out of every four.
5.6. The system shall have a manual control and automatic control, such as a
24-hour clock timer.
5.7. At the time of final inspection, the automatic control shall be set to operate
the whole -house fan according to the schedule used to calculate the whole -
house fan sizing.
5.8. A label shall be affixed to the control that reads "Whole House Ventilation
(see operating instructions)."
M1507.3.2.1 Operating' instructions. Installers shall provide the manufacturer's
installation, operating instructions, and a whole -house ventilation system operation
description.
M1507.3.3 Mechanical ventilation rate. The wholehouse mechanical ventilation
system shall provide outdoor air to each habitable space at a continuous rate of not
less than that determined in accordance with Table M1507.3.3(1).
Exception: The whole -house mechanical ventilation system is permitted to
operate intermittently where the system has controls that enable operation for
not less than 25 -percent of each 4 -hour segment and the ventilation rate
prescribed in Table M1507.3.3(1) is multiplied by the factor determined in
accordance with Table M1507.3.3(2).
Table M1507.3.3(1) Continuous Whole -House Mechanical
Ventilation System Airflow Rate Requirements
Dwelling Unit
Floor Area (sf)
Number of Bedrooms
0- 1 2 3 4- 5 6- 7
> 7
Airflow in CFM
< 1,500
30
45
60 75
90
1,501 - 3,000
45
60
75 1 90
105
3,001 - 4,500
60
75
I9i 105
120
4,501 - 6,000
75
90
105 1 120
135
6,001 - 7,500
90
105
120 1 135
150
> 7,500
105
120
135 150
165
Table M1507.3.3(2) Intermittent Whole -House
Mechanical Ventilation Rate Factors
Run -Time Percentage in
Each 4 -Hour Segment
25%
33%
50%
66%
75%
100%
Factor
4
3
2
1.5
1.3
1.0
SECTION M1507 - MECH. VENTILATION (WHOLE HOUSE VENTILATION)
(See 2015 Building Code for complete code section requirements)
M1507.3.4 Whole -house ventilation using exhaust fans. A system which meets
all the requirements of this section shall be deemed to satisfy the requirements for a
whole -house ventilation system.
M1507.3.4.1 Whole -house ventilation fans. Exhaust fans providing whole -house
ventilation shall meet the requirements of M1507.3.4.1 (reference original code)..
M1507.3.4.2 Fan noise. Whole -house fans noise ratings shall meet the
requirements of M1507.3.4.2 (reference original code). Remotely mounted fans
shall be acoustically isolated from the structural elements of the building and from
attached ductwork using insulated flexible duct or other approved material.
M1507.3.4.3 Fan controls. The whole -house ventilation fan shall meet the
requirements of Sections M1507.3.2 and M1507.3.2.1.
M1507.3.4.4 Ventilation opeings. Outdoor air shall be distributed to each habitable
space by individual outdoor air inlets. Where outdoor air supplies are separated
from exhaust points by doors, provisions shall be made to ensure air flow by
installation of distribution ducts, undercutting doors, installation of grilles, transoms,
or similar means. Doors shall be undercut to a minimum of 1/2 inch above the
surface of the finish floor covering.
Individual room outdoor air inlets shall:
1. Have controllable and secure openings;
2. Be sleeved or otherwise designed sous not to compromise the thermal
properties of the wall or window in which they are placed;
3. Provide not less than 4 square inches of net free area of opening for each
habitable space. Any inlet or combination of inlets which provide 10 cfm at 10
Pascals are deemed equivalent to 4 square inches net free area.
Inlets shall be screened or otherwise protected from entry by leaves or other
SD), SMOKE DETECTOR
EXHAUST FAN
50 CFM (min.) UNO
WINDOWS TO ALIGN w/ GARAGE
DOOR BLW. (SEE BLDG. ELEVATION)
3104 Western Avenue
Suite 107
Seattle WA 98121
206.204.0490
wwwmotion-space.com .:
ALIGN WINDOW C.L.
w/' ROOF RIDGE
material.
Outdoor air inlets shall be located sous not to take air from the following areas:
3.1. Closer than 10 feet from an appliance vent outlet, ;unless such vent outlet
is 3 feet above the outdoor air inlet.
3.2. Where it will pick up objectionable odors, fumes or flammable vapors.
3.3. A hazardous or unsanitary location.
3.4. A room or space having any fuel -burning appliances therein.
3.5. Closer than 10 feet from a vent opening of a plumbing drainage system
unless the vent opening is at least 3 feet above the air inlet.
3.6. Attic, crawl spaces, or garages.
LIFE SAFETY REQUIREMENTS
Stairs
Reference IRC R311.7
Minimum 36" clear width.
Maximum 7 3/4" rise.
Minimum 10" run.
Minimum 6'-8" head room.
Handrail 34"-38" above tread nosing.
Handrail grasping dimension 1-1/4" minimum - 2" maximum.
For winding stairs provide a minimum 10" tread at 12" from
the narrowest point.
MINI REF
SINK w/ FILTERED:
DRINKING WATER
Decks/Guardrails
Reference IRC R312
(E) D.S
RE-USEINSAME
LOCATION OR REPLACE:>
Guard (guardrail) required for walking surfaces 30" above
adjacent grade or floor below.
36" high required minimum.
4" maximum clear space between intermediate rails.
Smoke Detectors
Reference: IRC R314
(E) Bedroom
CONTRACTOR TO VERIFY THAT
EXISTING WHOLE: HOUSE. EXHAUST
FANIF'MEETSREQUIREMENTS ALL VEENTILATIONNOTMET:"
REQUIREMENTS.INSTALL NEW FAN
Detectors shall be installed in accordance with the approved
manufacturer's instructions and in accordance with IRC
R314.
Must be powered by interconnected building wiring, and have
battery back-up in new construction and additions and
anywhere where the interior surfaces of the space are
removed or access for wiring is available through a crawl
space or attic.
(E) CLOSET DOORS.
TO BE MOVED TO
THIS LOCATION
(e) attic access to
both new and
existing attic
spaces
1
Qom... 1
j; C; wv•;
$ 'ffi m w �
-lae®deiremmserisessil ad
May be battery -powered in alterations except when wiring
can be installed without removal of interior finishes.
Required in sleeping rooms, outside sleeping areas, and
other floors (including basements). Any alarm must be
clearly audible in all bedrooms.
Carbon Monoxide Alarms
Reference: IRC R315
For new construction, and for alterations, repairs and
additions to existing dwellings, that require a permit, an
approved carbon monoxide alarm shall be installed outside of
each separate sleeping area in the immediate vicinity of the
bedrooms in dwelling units.
(E) CLOSET DOORS
TO REMAIN
Date Revision Description .r
In a building where a tenancy exists, the tenant shall maintain
the alarm as specified by the manufacturer, including
replacement of the batteries.
Single station carbon monoxide alarms shall be listed as
complying with UL 2034 and shall be installed in accordance
with this code and the manufacturer's installation instructions.
Emergency Escape & Rescue
Reference IRC R310
One window (or door) in basement and each bedroom must
meet these requirements:
5.7 sq. ft. minimum net clear open area (windows with
maximum sill height 44" above or below grade may have 5.0
sq. ft minimum net clear open area).
20" minimum clear open width.
24" minimum clear open height.
44" maximum sill height.
Window wells require minimum 3'x3' but must permit full
opening of window. Ladder escape okay.
® Without Comments
As Not:ec ire kr,*
Per The Atthcrl;_ Letter
These plans have been reviewed by Toe Tukwila Fire
Prevention Bureau ON cclformance v,:th current City
standards. Accepranc(,, '5u)ject to errors and
omissions which do noc authorize violations of adopted
Standards andordinances. The resoonsibflity for the
adequacy of design Yotally with th ieslgrier.
Additions, deletions a,, , i.:vsioris to these drawings after
this date will void this acceptance and will equire a
resubmfttai of revised drawings fol. StIbSegUeIlt approval.
Final acceptance is suuject to field test and Inspection by
The Tukwlia Fire Prevention Bureau.
Date: (e -� "A> By:
.�f
-1-7,A5-6.11 ah e '-ievry w
dio reci sir-e-ok
4 fio.,Cva,dr) 40r- reciiv4
111;(10.1T DEPARTMENT
Q.575..;..07 and
give this r ii e Permit No.
and e x ctF ,7;"l e iSs ?Or shut
ck-fmn or r\2!starraiion approval.
(A)L
(E) DS
1
A5,0
REMOVE EXISTING FLUE
AND PATCH ROOFING
LINE OF WALL BELOW, TYP
Roof Ventilation Code
Reference: R806.1, R806.2, R806.3
Enclosed attics and enclosed rafter spaces formec where ceilings are applied directly to the underside
of roof rafters shall have cross ventilation for each separate space by ventilating openings protected
against the entrance of rain or snow, Ventilating openings shall be provided with corrosion -resistant wire
mesh with 1/8 inch minimum to 1/4 inch maximum openings. The total net free ventilating area shall not
be less that 1/150 of the area of the space ventilated, but may be reduced to 1/300, provided that at least
40 percent and not more than 50 percent of the required ventilating area is provided by ventilators
located in the upper portion of the space. to be ventilated no more than 3 feet below the ridge or highest
point of the space, measured vertically, with the balance of the required ventilation provided by eave or
cornice vents. Where the location of wall or roof framing members conflicts with the installation of upper
ventilators, installation more than 3 feet below the ridge or highest point of the space shall be permitted.
As an alternative, the net free cross -ventilation area may be reduced to 1/300 when a vapor barrier
having a transmission rate not exceeding 1 perm Is installed on the warm -in -the -winter side of the ceiling.
Where eave or cornice vents are installed, insulation shall not block the free flow of air. A minimum of a
1 -inch space shall be provided between the insulation and the roof sheathing and at the location of the
vent.
Roof ventilation calculations:
Required Area 1,491 x 1/300 (w/ vapor barrier) = 716 sq in.
Provided Area = Soffit: 8.5 SVLF.x'99 LF = 842 sq in.
Ridge: 18 SVLF x 49`-6" = 891 sq in.
Total: 1,733 sq in.
111 z .poly
Km -k• irO a
WALL KEY
New Wall
Existing Wall
Demo Wall
DEMO (E) BATHROOM.
CONNECT NEW PLUMBING
TO EXISTING SEWER LINE. ---
45 CFM MIN CONTINOUS
OPERATION WHOLE
HOUSE EXHAUST FAN PER
IRC M1507.3:3 (1) ,.
Tj -
1
t.
•
1
I
--1-
1:
L
L
I..
•
1I.
?:.......:...l
--.:1.;.
I
,..(E) RIDGE
EXISTING ASPHALT
L . SHINGLE ROOFING,..__;-,
J........_..
i..
(E) HOSE BIB
LIFE SAFETY REQUIREMENTS
Stairs
Reference IRC R311.7
Minimum 36" clear width.
Maximum 7 3/4" rise.
Minimum 10" run.
Minimum 6'-8" head room.
Handrail 34"-38" above tread nosing.
Handrail grasping dimension 1-1/4" minimum - 2" maximum.
For winding stairs provide a minimum 10" tread at 12" from
the narrowest point.
Decks/Guardrails
Reference IRC R312
Guard (guardrail) required for walking surfaces 30" above adjacent
grade or floor below.
36" high required minimum,
4" maximum clear space between intermediate rails.
Carbon Monoxide Alarms
Reference: IRC R315
For new construction, an approved carbon monoxide alarm shall
be installed outside of each separate sleeping area in the
immediate vicinity of the bedrooms in dwelling units.
In a building where a tenancy exists, the tenant shall maintain the
alarm as specified by the manufacturer, including replacement of
the batteries.
Single station carbon monoxide alarms shall be listed as
complying with UL 2034 and shall be installed in accordance with
this code and the manufacturer's installation instructions.
Smoke Detectors
Reference: IRC R314
Detectors shall be installed in accordance with the approved
manufacturer's instructions and in accordance with IRC R314,
Must be powered by interconnected building wiring, and have battery
back-up In new construction and additions and anywhere where the
interior surfaces of the space are removed or access for wiring is
available through a crawl space or attic.
May be battery -powered in alterations except when wiring can be
installed without removal of interior finishes.
Required in sleeping rooms, outside sleeping areas, and other
floors (including basements). Any alarm must be clearly audible in
all bedrooms.
Emergency Escape & Rescue
Reference IRC R310
One window (or door) in basement and each bedroom must meet
these requirements:
5.7 sq. it minimum net clear open area (windows with maximum sill
height 44" above or below grade may have 5.0 sq. ft minimum net
clear open area).
20" minimum clear open width.
24" minimum clear open height.
44" maximum sill height.
Window wells require minimum 3'x3' but must permit full opening of
window. Ladder escape okay.
REMOVE (E) LEAN-TO
41' - 51 /2"
UP I
FLOOR DRAIN —
COMBINED ELECTRIC
HOT WATER HEATER
AND BOILER -
1
1::::::.....L
•• ----1--
•
•
? -i
•
?...ti.,.
11 1/2'
LLI
:
.
i..........1
1 '
:...._....l... .._L ......... .......
__:'i:::...::i:::::
•
1
(B
i
........_........ ......... 1
(E) DS
( )
rNA, Roof Plan
1 /4" = 1'-0"
1
---- NEW ROOF
AT ENTRY
V
.(;+-3.+) 2
NEW ELEC PANEL
(RELOCATED
FROM BEDROOM)
(E) DOWNSPOUTS
TO REMAIN (TYP)
7' - 5 1/2"
(06)
4' - 0"
1(05) EQ
14' - 1 1/2"
/02)
(Os)
1/04)
1
1 00
wt pg
parte
tiqlz
00)
ZWZ
425
Wg
re
t
11):
50 CFM MIN
EGRESS
erIN Floor Plan
(E) DRIVEWAY
1112
EXISTING WALL TO
DOORS, TYP)
2 REMAIN (INFILL
WALL AT REMOVED
CARBON MONOXIDB
AND SMOKE :
DETECTOR -
DETECTOR, TYP
RELOCATE
EXISTING
ELEC PANEL
TO GARAGE
M 13.09
0
3104 Western Avenue
Suite 107
Seattle WA 98121
t: 206.204.0490
f: 206.219.5682
www.motion-space.com
\ REGISTERED
1 ARCHITECT
NAZIM NICE
or'.. STATE OF WASHINGTON I
(c)
.0 cci
715
FE
Lamm —C
CD '1!
Cr CZ?"
No,
Date Revision Description'
CA
PAID
io 2016
TUKWILA FIRE
Pit
0
les
up CV
Ca 8
'
1
/
• .;.
.
;
0
66x32
,N. Bedroom ,
. .
j
• 2x6 WALL
:171.1Z
---, - -
. ,
•
-.,
II
. .
, .
-
.
*
-100 CFM MIN VENT HOOD ABV .
.
7' - 5 1/2"
(06)
4' - 0"
1(05) EQ
14' - 1 1/2"
/02)
(Os)
1/04)
1
1 00
wt pg
parte
tiqlz
00)
ZWZ
425
Wg
re
t
11):
50 CFM MIN
EGRESS
erIN Floor Plan
(E) DRIVEWAY
1112
EXISTING WALL TO
DOORS, TYP)
2 REMAIN (INFILL
WALL AT REMOVED
CARBON MONOXIDB
AND SMOKE :
DETECTOR -
DETECTOR, TYP
RELOCATE
EXISTING
ELEC PANEL
TO GARAGE
M 13.09
0
3104 Western Avenue
Suite 107
Seattle WA 98121
t: 206.204.0490
f: 206.219.5682
www.motion-space.com
\ REGISTERED
1 ARCHITECT
NAZIM NICE
or'.. STATE OF WASHINGTON I
(c)
.0 cci
715
FE
Lamm —C
CD '1!
Cr CZ?"
No,
Date Revision Description'
CA
PAID
io 2016
TUKWILA FIRE
Pit
0
les
up CV
Ca 8
PRE £1061,uE£f El? RooF
TRus3E3 Arz oG
Zxlo ATI6"o4
SEG rzc?AJ
3/r_1
•
t
LitiZA ' Rooms
ENTQY
DtNIN& ReoK
0
i
t
STAIRwA '
IMP
} FA/ lrty Room
•
1
•
q
•
t
f
a
t
f
ur Z70
r
I Kz TC.rt FN
FrA3 Ft, oo P
t
•
f
1
1
PLO"- hLA/J1073
t
ACCEPTED
❑ rl�alai,^L't Ccrnrrenfs
As t.c+ci In Red
❑ Per The AL acted Letter
l,Thco3 p a 3 loci been rt -/'o cd by The I uk' 'Ila Fire
n..
r-`-revc'-tt an B '..?au for cot 3.."T`.a ce , 41 cu. -.3^t city
:ta1aa-os flcco C "-i..o. is s" ).jao' to c rcrs and
:"'n`¢33 C"3 WJiliri' .:13 rs'..°t lcrrn 1.1c o Y'3 0' odor 2`d
II E atiea d a-a-oF"i,r--,za Tie r:.s e oi-i' > 43r ''3
fr
f,adegiuo.cy o L?ool= - re cs totally v tn i die de., cY'sr
Add 1 ons dL e ci R o- Y7,‘ : 3 It.) thew d-& ris e ler
ri3dEe.r,1'‘oc ri'sa:settimesand w'r q lea
resuomlr`ai or ravicL," d=a.iiras crs.ibscctt,ent approval
F nal acceptance's Subject to field test and inspection by
The Tukwila Fire Prevention Bureau
Date / � ^ By
rUKWILA FIRE DEPARTMENT
Please call 575 4407
and give this job
No 0 0 - , 3391
cad exact address for shuts
own or restoration approval
f
BEDR ovM
OL
sTAzRwAY
BATH AfioMA
13Ep,Qooe-N
1
-47
Of
7'
GL os,E'T
ccos(r
3 4Tf9 Boo
0
1
SE o#00 F400# PLAA)
Y411==ii
t it/ATER FLO J
INPJtff r oR
Y
riipte4KFLow
vEAvTg
To Doric,.
\15'12 A
T,s
TQs tisram
(a) For coverage area dimensions less than or between those
indicated it is necessary to use the minimum required flow for
the next highest coverage area for which hydraulic design
cntena are stated
(b) Requirement is based on mintmurn flow in GPM from each
sprinkler The associated residual pressures are calculated
using the nominal K -tactor Refer to Hydraukc Design Criteria
Section for details
TABLE A
HYDRAULIC DESIGN CRITERIA
piete list of criteria prior to Initiating the design of the
sprinkler system
Questions concerning sprinkler Installation and us-
age criteria which are not covered by the following In-
structions should be submitted to Star Spnnkler Inc
Include *hitches and technical details as appropriate
In some instances the requirements of this docu-
ment may concern specifications which are more
stringent and which take precedence over those
specified in NFPA 13 NFPA 13D NFPA 13R or by the =
authority having Jurisdiction
The spray from the sprinkler is distributed radially
outward and downward from the sprinkler deflector
Consequently the sprinklers must be located such
that there will not be any blind spaces shielded from
spray by partitions room dividers, overhangs or
other parts of the dwelling structure
The number of sprinklers within each compartment
(as defined by NFPA 13, 13D, or 13R) must be kept
as few as possible Do NOT use more sprinklers than
necessary to cover a particular space
Use only the escutcheon provided with the Celeste
S220
The sprinkler must be secured in position by lily
fastening the sprinkler system piping to the struc-
ture If the sprinkler is not properly secured In posi-
tron, react forces resulting from spnnkler opera
tion col atter its orientation and its water
distribution pattern The sprinkler escutcheon cannot
be used to hold the sprinkler in position
General Service Conditions The Celeste S220 must
only be utilized in wet pipe sprinkler systems
Thermal Response Criteria M residential sprinklers m-
9/32 (7 4 mm)TYP
--FADE tJ
DO NOT_� SPININhLGR
OVER -TIGHTEN
I I 4
f 4
1
CEILING LEVEL
TOLERANCE
LIMIT
A
_ 29/32:3/16
(23 014 8 mm)
PROTECTIVE CAP
+. 2• (so rim) DIA. —•-t
MOUNTING
SURFACE
SPRINKLER
WRENCHING
AREA
B
HEAT
J___ COLLECTOR
--- 2 9/16• (65 mm) D.A.
1/2' NPT
7/16' (11 1 mm)
NOMINAL MAKE iN
C
-."1./88141111111111111.3111.7P'
DEFLECTOR
IN OPERATED
POSITION
FIGURE 1
CELESTE S220 RESIDENTIAL
FLUSH PENDENT SPRINKLER
stalled within a compartment (as defined by relevant
NFPA standards) must be of the same heat response ther-
mal charactensttcs and their temperature ratings are to
be within 10°F (5 5°C) of edch other
Hydraulic Design Criter'a The minimum required single
and multiple sprinkler Clow rates are given in Table A as a
function of temperature rating and the maximum allow-
able coverage areas The single sprinkler flow rate is the
minimum required discharge from the most hydraulically
demanding single sprinkler and the multiple spnnkler
Hangers and Supports
Nominal Pipe Size
Inches (mm)
Maximum Support Spacing
Feet (meters)
3/4
1
1 1/4
1 1/2
2
2 1/2
3
(20)
(25)
(30)
(40)
(50)
(65)
(80)
5 1/2
6
6 1/2
7
8
9
10
(1 7)
(1 8)
(20)
(2 1)
(2 4)
(2 7)
(3 0)
FILE
pitE.501k. 6,406.E
0 DRAWVA
petOvvr. Ta"5
" t 27D0
To IIErek
Y6
55 F MBL y
TABLE A
Maximum Support Spacing Distance End Line Spnnkler Head Drop Elbow
Nominal Pipe Size Less than 100 psi
(in) (mm)
(in) (mm)
More than 100 psi
(in) (mm)
314'
1"
1 1/4"
1 1/2" 3"
(20)
(25)
(32)
(40 80)
9"
12"
16"
24"
(228 6)
(304 8)
(406 4)
(609 6)
6"
9"
12"
12"
(152 4)
(228 6)
(304 8)
(304 4)
TABLE B
Maximum Support Spacing Distance Inline Sprinkler Head Drop Tee
Nominal Pipe Size
(in) (mm)
Less than 100 psi More than 100 psi
(in) (m)
(in) (m)
3/4"
1 1/4"
1 1/2" 3"
(20)
(25)
(32)
(40-80)
4
5
6
7
(1 2)
j15)
(1 8)
(2 1)
3
4
5
7
GENERAL NOTES FOR 13 D SYSTEMS
1. Owner to provide adequate heat (40°F Min ) To prevent
sprinklers pipes from freezing
2. Owner to provide hard wired home smoke detection system.
3 CPVC Pipe shalt have hangers 6'-0 cic and not more than 6'
from any sprinkler head.
I
SPRINKLERS USED
411 Z O k REST OEN c. E
SYM
0
SPRINKLER ORIFICE
SIZE, TYPE & FINISH
QUAN
TEMP
STAR c6-LEsTA. stip
23
16 Z
R
�-!g 13 .a IyGTH .5T 7"ukwrt,L,4 l,✓A
0.5z,0402-41_, PE-atlur
TOTAL
23
NOV -82000
RiNITY
FIRE
PROTECTIC lA I l>
11021 CRAMER RD KP N TRINIFP101 OK
GIG HARBOR WA 98329 PHONE 253 857-5222
L
ATE ll-L*ctmg M N
G 1 gF
MAXiMUM
COVERAGE
AREA*
FTxFT
SINGLE
SPRINKLER
Minimum Flow rot
(Residual Pressure)
—
MULTIPLE
SPRINKLERS
Minimum Flow tit►
(Residual Pressure)
162°F
162'F
—
12x12
13 GPM
(11 1 PSI)
13 GPM
(11 1 PSI)
14 x 14
13 GPM
(11 1 PSI)
13 GPM
J11 1 PSI)
i
16x16
13 GPM
(11 1 PSi)
13 M
411 1 PSi)
7
18x18
14 GPM
(12 9 PSI)
13 GPM
(11 1 PSi)
20x20
19 GPM
(23.7 PSi)
19 GPM
(23.7 PSI)
(a) For coverage area dimensions less than or between those
indicated it is necessary to use the minimum required flow for
the next highest coverage area for which hydraulic design
cntena are stated
(b) Requirement is based on mintmurn flow in GPM from each
sprinkler The associated residual pressures are calculated
using the nominal K -tactor Refer to Hydraukc Design Criteria
Section for details
TABLE A
HYDRAULIC DESIGN CRITERIA
piete list of criteria prior to Initiating the design of the
sprinkler system
Questions concerning sprinkler Installation and us-
age criteria which are not covered by the following In-
structions should be submitted to Star Spnnkler Inc
Include *hitches and technical details as appropriate
In some instances the requirements of this docu-
ment may concern specifications which are more
stringent and which take precedence over those
specified in NFPA 13 NFPA 13D NFPA 13R or by the =
authority having Jurisdiction
The spray from the sprinkler is distributed radially
outward and downward from the sprinkler deflector
Consequently the sprinklers must be located such
that there will not be any blind spaces shielded from
spray by partitions room dividers, overhangs or
other parts of the dwelling structure
The number of sprinklers within each compartment
(as defined by NFPA 13, 13D, or 13R) must be kept
as few as possible Do NOT use more sprinklers than
necessary to cover a particular space
Use only the escutcheon provided with the Celeste
S220
The sprinkler must be secured in position by lily
fastening the sprinkler system piping to the struc-
ture If the sprinkler is not properly secured In posi-
tron, react forces resulting from spnnkler opera
tion col atter its orientation and its water
distribution pattern The sprinkler escutcheon cannot
be used to hold the sprinkler in position
General Service Conditions The Celeste S220 must
only be utilized in wet pipe sprinkler systems
Thermal Response Criteria M residential sprinklers m-
9/32 (7 4 mm)TYP
--FADE tJ
DO NOT_� SPININhLGR
OVER -TIGHTEN
I I 4
f 4
1
CEILING LEVEL
TOLERANCE
LIMIT
A
_ 29/32:3/16
(23 014 8 mm)
PROTECTIVE CAP
+. 2• (so rim) DIA. —•-t
MOUNTING
SURFACE
SPRINKLER
WRENCHING
AREA
B
HEAT
J___ COLLECTOR
--- 2 9/16• (65 mm) D.A.
1/2' NPT
7/16' (11 1 mm)
NOMINAL MAKE iN
C
-."1./88141111111111111.3111.7P'
DEFLECTOR
IN OPERATED
POSITION
FIGURE 1
CELESTE S220 RESIDENTIAL
FLUSH PENDENT SPRINKLER
stalled within a compartment (as defined by relevant
NFPA standards) must be of the same heat response ther-
mal charactensttcs and their temperature ratings are to
be within 10°F (5 5°C) of edch other
Hydraulic Design Criter'a The minimum required single
and multiple sprinkler Clow rates are given in Table A as a
function of temperature rating and the maximum allow-
able coverage areas The single sprinkler flow rate is the
minimum required discharge from the most hydraulically
demanding single sprinkler and the multiple spnnkler
Hangers and Supports
Nominal Pipe Size
Inches (mm)
Maximum Support Spacing
Feet (meters)
3/4
1
1 1/4
1 1/2
2
2 1/2
3
(20)
(25)
(30)
(40)
(50)
(65)
(80)
5 1/2
6
6 1/2
7
8
9
10
(1 7)
(1 8)
(20)
(2 1)
(2 4)
(2 7)
(3 0)
FILE
pitE.501k. 6,406.E
0 DRAWVA
petOvvr. Ta"5
" t 27D0
To IIErek
Y6
55 F MBL y
TABLE A
Maximum Support Spacing Distance End Line Spnnkler Head Drop Elbow
Nominal Pipe Size Less than 100 psi
(in) (mm)
(in) (mm)
More than 100 psi
(in) (mm)
314'
1"
1 1/4"
1 1/2" 3"
(20)
(25)
(32)
(40 80)
9"
12"
16"
24"
(228 6)
(304 8)
(406 4)
(609 6)
6"
9"
12"
12"
(152 4)
(228 6)
(304 8)
(304 4)
TABLE B
Maximum Support Spacing Distance Inline Sprinkler Head Drop Tee
Nominal Pipe Size
(in) (mm)
Less than 100 psi More than 100 psi
(in) (m)
(in) (m)
3/4"
1 1/4"
1 1/2" 3"
(20)
(25)
(32)
(40-80)
4
5
6
7
(1 2)
j15)
(1 8)
(2 1)
3
4
5
7
GENERAL NOTES FOR 13 D SYSTEMS
1. Owner to provide adequate heat (40°F Min ) To prevent
sprinklers pipes from freezing
2. Owner to provide hard wired home smoke detection system.
3 CPVC Pipe shalt have hangers 6'-0 cic and not more than 6'
from any sprinkler head.
I
SPRINKLERS USED
411 Z O k REST OEN c. E
SYM
0
SPRINKLER ORIFICE
SIZE, TYPE & FINISH
QUAN
TEMP
STAR c6-LEsTA. stip
23
16 Z
R
�-!g 13 .a IyGTH .5T 7"ukwrt,L,4 l,✓A
0.5z,0402-41_, PE-atlur
TOTAL
23
NOV -82000
RiNITY
FIRE
PROTECTIC lA I l>
11021 CRAMER RD KP N TRINIFP101 OK
GIG HARBOR WA 98329 PHONE 253 857-5222
L
ATE ll-L*ctmg M N
G 1 gF