Loading...
HomeMy WebLinkAboutPP - 4815 S 146TH ST - UNKNOWN - PERMITS AND PLANS4815 S 146TH ST ASSOCIATED PERMITS 01-5-192 D01-061 Ciz of Tukwila Steven M Mullet, Mayor Fire Department Project Name TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM lT�(ot ZvV 51 ,Le '4( Thomas P. Keefe, Fire Chief Permit No. too/ ` Q (0/ Address t'lS S /y - Retain current inspection schedule Needs shift inspection Suite # Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: -4-cf---)/1,‘,6 Tl90 J/ 5/l , of Authorized Sign'ture Date FINALAPP.FRM Rev. 2/19/98 T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: 206-575-4404 • Fax: 206-575-4439 FIRE SYSTEMS WEST 219 FRONTAGE ROAD NORTH, SUITE B PACIFIC, WA 98047 (253) 833-1248 HYDRAULIC CALCULATIONS FOR GADZUK RESIDENCE 4815 SOUTH 146TH STREET TUKWILA, WA 98168 FILE NUMBER: 5984#1 DATE: AUG 22, 2001 -DESIGN DATA - OCCUPANCY CLASSIFICATION: NFPA 13D (2 Head Calculation) DENSITY: 17 gpm/sprinkler AREA OF APPLICATION: MASTER SUITE COVERAGE PER SPRINKLER: 18' X 18' Maximum NUMBER OF SPRINKLERS CALCULATED: 2 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 34.1 gpm TOTAL WATER REQUIRED (including hose): 34.1 gpm FLOW AND PRESSURE (@ BOR): 34.1 GPM @ 37.1 PSI SPRINKLER ORIFICE SIZE: 3/8 inch NAME OF CONTRACTOR: FIRE SYSTEMS WEST, INC. DESIGN/LAYOUT BY: JIM STEWART AUTHORITY HAVING JURISDICTION: TUKWILA FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: FIRE SWI 140B1 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 0 I5825A ) HRS SYSTEMS, INC. ATLANTA, GA DATE: 8/22/2001 JOB TITLE: GADZUK RESIDENCE WATER SUPPLY DATA SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 D:\HASSFILE\5984#1.SDF SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SRC 92.0 20.0 1700.0 91.9 34.1 83.3 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE TOTAL HOSE STREAM ALLOWANCE AT SOURCE OTHER HOSE STREAM ALLOWANCES TOTAL DISCHARGE FROM ACTIVE SPRINKLERS NODE ANALYSIS DATA 34.1 GPM 0.0 GPM 0.0 GPM 34.1 GPM NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 22.0 K= 4.20 16.4 17.0 2 22.0 K= 4.20 16.5 17.1 A 22.0 17.0 - - - B 22.0 18.5 C 12.0 23.8 D 12.0 24.4 E 4.0 29.6 TOR 12.0 24.7 BOR 2.0 37.1 BF1 3.5 31.2 BF2 3.5 36.2 S1 -3.0 48.7 - S2 2.0 42.8 - S3 2.0 41.1 - S4 2.0 38.9 - M1 -3.0 53.4 M2 -3.0 - - - - 57.4 - - - SRC -3.0 SOURCE 83.3 34.1 DATE: 8/22/2001 JOB TITLE: GADZUK RESIDENCE PIPE DATA SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 D:\HASSFILE\5984#1.SDF PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -17.0 1.101 PL 7.50 PF 0.6 1 22.0 4.2 16.4 17.0 5.7 150 FTG T PE 0.0 A 22.0 0.0 17.0 0.0 0.050 TL 12.50 PV 0.2 Pipe: 2 -17.1 1.101 PL 5.00 PF 0.5 2 22.0 4.2 16.5 17.1 5.7 150 FTG T PE 0.0 A 22.0 0.0 17.0 0.0 0.051 TL 10.00 PV 0.2 A B C C D Pipe: 3 -34.1 1.394 PL 20.00 PF 1.5 22.0 0.0 17.0 0.0 7.2 150 FTG T PE 0.0 22.0 0.0 18.5 0.0 0.058 TL 26.00 PV 0.3 Pipe: 4 -34.1 1.394 PL 10.00 PF 0.9 22.0 0.0 18.5 0.0 7.2 150 FTG T PE 4.3 12.0 0.0 23.8 0.0 0.058 TL 16.00 PV 0.3 Pipe: 5 -34.1 1.394 PL 5.25 PF 0.6 12.0 0.0 23.8 0.0 7.2 150 FTG T PE 0.0 12.0 0.0 24.4 0.0 0.058 TL 11.25 PV 0.3 Pipe: 6 -34.1 1.394 PL 4.50 PF 0.3 D 12.0 0.0 24.4 0.0 7.2 150 FTG ---- PE 0.0 TOR 12.0 0.0 24.7 0.0 0.058 TL 4.50 PV 0.3 Pipe: 7 -34.1 1.380 PL 9.50 PF 1.4 TOR 12.0 0.0 24.7 0.0 7.3 120 FTG T PE 3.5 E 4.0 0.0 29.6 0.0 0.092 TL 15.50 PV 0.4 Pipe: 8 -34.1 1.380 PL 2.00 PF 1.4 E 4.0 0.0 29.6 0.0 7.3 120 FTG CB PE 0.2 BF1 3.5 0.0 31.2 0.0 0.092 TL 15.00 PV 0.4 Pipe: 9 FIXED PRESSURE LOSS DEVICE BF2 3.5 0.0 36.2 0.0 5.0 psi, 34.1 gpm BF1 3.5 0.0 31.2 0.0 Pipe: 10 -34.1 1.055 PL 1.50 PF 0.3 BF2 3.5 0.0 36.2 0.0 12.5 150 FTG ---- PE 0.6 BOR 2.0 0.0 37.1 0.0 0.224 TL 1.50 PV 1.1 Pipe: 11 -34.1 1.055 PL 2.00 PF 1.8 BOR 2.0 0.0 37.1 0.0 12.5 150 FTG 2E PE 0.0 S4 2.0 0.0 38.9 0.0 0.224 TL 8.00 PV 1.1 Pipe: 12 -34.1 1.291 PL 12.00 PF 2.1 S4 2.0 0.0 38.9 0.0 8.3 150 FTG 3E PE 0.0 S3 2.0 0.0 41.1 0.0 0.084 TL 25.50 PV 0.5 Pipe: 13 -34.1 1.291 PL 2.00 PF 1.7 S3 2.0 0.0 41.1 0.0 8.3 150 FTG CB PE 0.0 S2 2.0 0.0 42.8 0.0 0.084 TL 20.60 PV 0.5 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 8/22/2001 D:\HASSFILE\5984#1.SDF JOB TITLE: GADZUK RESIDENCE PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 14 -34.1 1.291 PL 22.00 PF 3.7 S2 2.0 0.0 42.8 0.0 8.3 150 FTG 5E PE 2.2 S1 -3.0 0.0 48.7 0.0 0.084 TL 44.50 PV 0.5 Pipe: 15 -34.1 1.250 PL 48.00 PF 4.7 S1 -3.0 0.0 48.7 0.0 8.9 150 FTG ---- PE 0.0 M1 -3.0 0.0 53.4 0.0 0.098 TL 48.00 PV 0.5 Pipe: 16 FIXED PRESSURE LOSS DEVICE M2 -3.0 0.0 57.4 0.0 4.0 psi, 34.1 gpm M1 -3.0 0.0 53.4 0.0 Pipe: 17 -34.1 1.291 PL 300.00 PF 25.8 M2 -3.0 0.0 57.4 0.0 8.3 150 FTG B PE 0.0 SRC -3.0 SRCE 83.3 (N/A) 0.084 TL 308.00 PV 0.5 NOTES: (1) Calculations were performed by the HASS 7.3 computer program under license no. 5009058210 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 (2) The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.004 gpm. (3) Velocity pressures are printed for information only and are not used in balancing the system. Maximum water velocity is 12.5 ft/sec at pipe 11. (4) PIPE FITTINGS TABLE Pipe Table Name: FSW-STD.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVly BfyVly GatV1v AlmChk DPV1v NPTee 1.380 3.00 6.00 2.00 7.00 6.00 1.00 10.00 10.00 6.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 8/22/2001 D:\HASSFILE\5984#1.SDF JOB TITLE: GADZUK RESIDENCE PAGE: A Diameter (in) 1.380 PAGE: F Diameter (in) 1.101 1.394 PAGE: I Diameter (in) 1.055 1.291 MATERIAL: SCH40 Equivalent E T L Ell Tee LngEll 3.00 6.00 2.00 MATERIAL: CPVC Equivalent E T L Ell Tee LNG -EL 7.00 5.00 0.10 8.00 6.00 0.10 MATERIAL: Copper Equivalent E T C Ell Tee ChkVly 3.00 7.50 7.60 4.50 9.10 10.60 HWC: 120 Fitting Lengths in Feet C B G A ChkV1v BfyVly GatVly AlmChk 7.00 6.00 1.00 10.00 D DPV1v 10.00 HWC: 150 Fitting Lengths in Feet C B G A D CHKVLV BFYVLV GT-VLV ALMVLV DRYVLV 0.10 0.10 0.10 0.00 0.00 0.10 0.10 0.10 0.00 0.00 HWC: 150 Fitting Lengths in Feet B BfyVly 8.00 8.00 DATE: 8/22/2001 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 D:\HASSFILE\5984#1.SDF JOB TITLE: GADZUK RESIDENCE WATER SUPPLY ANALYSIS Static: 92.00 psi Resid: 20.00 psi Flow: 1700.0 gpm 100.0 1 2 80.0 G A U G E 60.0 P R E S S U R 40.0 E P s i 20.0 0.0 -14.7 1 1 1 2 400600 800 1000 1200 1400 1600 1800 2000 FLOW (GPM) LEGEND Available pressure 91.95 psi @ 34.1 gpm Required pressure 63.25 psi @ 34.1 gpm FIRE SYSTEMS WEST 219 FRONTAGE ROAD NORTH, SUITE B PACIFIC, WA 98047 (253) 833-1248 HYDRAULIC CALCULATIONS FOR GADZUK RESIDENCE 4815 SOUTH 146TH STREET TUKWILA, WA 98168 FILE NUMBER: 5984#2 DATE: AUG 22, 2001 -DESIGN DATA- fil•tuip ay. te OCCUPANCY CLASSIFICATION: NFPA 13D (1 Head Calculation) DENSITY: 24 gpm/sprinkler AREA OF APPLICATION: MASTER SUITE COVERAGE PER SPRINKLER: 18' X 18' Maximum NUMBER OF SPRINKLERS CALCULATED: 1 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 24.0 gpm TOTAL WATER REQUIRED (including hose): 24.0 gpm FLOW AND PRESSURE (@ BOR): 24.0 GPM @ 50.9 PSI SPRINKLER ORIFICE SIZE: 3/8 inch NAME OF CONTRACTOR: FIRE SYSTEMS WEST, INC. DESIGN/LAYOUT BY: JIM STEWART AUTHORITY HAVING JURISDICTION: TUKWILA FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: FIRE SWI 140B1 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 0 I5825A ) HRS SYSTEMS, INC. ATLANTA, GA DATE: 8/22/2001 JOB TITLE: GADZUK RESIDENCE WATER SUPPLY DATA SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 D:\HASSFILE\5984#2.SDF SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SRC 92.0 20.0 1700.0 92.0 24.0 78.0 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE TOTAL HOSE STREAM ALLOWANCE AT SOURCE OTHER HOSE STREAM ALLOWANCES TOTAL DISCHARGE FROM ACTIVE SPRINKLERS NODE ANALYSIS DATA 24.0 GPM 0.0 GPM 0.0 GPM 24.0 GPM NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 22.0 K= 4.20 32.7 24.0 2 22.0 - - - - 33.8 A 22.0 33.8 B 22.0 34.6 C 12.0 39.4 D 12.0 39.8 E 4.0 44.1 TOR 12.0 39.9 BOR 2.0 50.9 BF1 3.5 - 45.1 BF2 3.5 50.1 S1 -3.0 58.0 S2 2.0 53.9 S3 2.0 53.0 S4 2.0 51.8 M1 -3.0 60.4 M2 -3.0 - - - - 64.4 - - - SRC -3.0 SOURCE 78.0 24.0 DATE: 8/22/2001 JOB TITLE: GADZUK RESIDENCE PIPE DATA SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 D:\HASSFILE\5984#2.SDF PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -24.0 1.101 PL 7.50 PF 1.2 1 22.0 4.2 32.7 24.0 8.1 150 FTG T PE 0.0 A 22.0 0.0 33.8 0.0 0.095 TL 12.50 PV 0.4 Pipe: 2 0.0 1.101 PL 5.00 PF 0.0 2 22.0 0.0 33.8 0.0 0.0 150 FTG T PE 0.0 A 22.0 0.0 33.8 0.0 0.000 TL 10.00 PV 0.0 Pipe: 3 -24.0 1.394 PL 20.00 PF 0.8 A 22.0 0.0 33.8 0.0 5.0 150 FTG T PE 0.0 B 22.0 0.0 34.6 0.0 0.030 TL 26.00 PV 0.2 Pipe: 4 -24.0 1.394 PL 10.00 PF 0.5 B 22.0 0.0 34.6 0.0 5.0 150 FTG T PE 4.3 C 12.0 0.0 39.4 0.0 0.030 TL 16.00 PV 0.2 Pipe: 5 -24.0 1.394 PL 5.25 PF 0.3 C 12.0 0.0 39.4 0.0 5.0 150 FTG T PE 0.0 D 12.0 0.0 39.8 0.0 0.030 TL 11.25 PV 0.2 Pipe: 6 -24.0 1.394 PL 4.50 PF 0.1 D 12.0 0.0 39.8 0.0 5.0 150 FTG ---- PE 0.0 TOR 12.0 0.0 39.9 0.0 0.030 TL 4.50 PV 0.2 Pipe: 7 -24.0 1.380 PL 9.50 PF 0.7 TOR 12.0 0.0 39.9 0.0 5.1 120 FTG T PE 3.5 E 4.0 0.0 44.1 0.0 0.048 TL 15.50 PV 0.2 Pipe: 8 -24.0 1.380 PL 2.00 PF 0.7 E 4.0 0.0 44.1 0.0 5.1 120 FTG CB PE 0.2 BF1 3.5 0.0 45.1 0.0 0.048 TL 15.00 PV 0.2 Pipe: 9 FIXED PRESSURE LOSS DEVICE BF2 3.5 0.0 50.1 0.0 5.0 psi, 24.0 gpm BF1 3.5 0.0 45.1 0.0 Pipe: 10 -24.0 1.055 PL 1.50 PF 0.2 BF2 3.5 0.0 50.1 0.0 8.8 150 FTG ---- PE 0.6 BOR 2.0 0.0 50.9 0.0 0.117 TL 1.50 PV 0.5 Pipe: 11 -24.0 1.055 PL 2.00 PF 0.9 BOR 2.0 0.0 50.9 0.0 8.8 150 FTG 2E PE 0.0 S4 2.0 0.0 51.8 0.0 0.117 TL 8.00 PV 0.5 Pipe: 12 -24.0 1.291 PL 12.00 PF 1.1 S4 2.0 0.0 51.8 0.0 5.9 150 FTG 3E PE 0.0 S3 2.0 0.0 53.0 0.0 0.044 TL 25.50 PV 0.2 Pipe: 13 -24.0 1.291 PL 2.00 PF 0.9 S3 2.0 0.0 53.0 0.0 5.9 150 FTG CB PE 0.0 S2 2.0 0.0 53.9 0.0 0.044 TL 20.60 PV 0.2 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 8/22/2001 D:\HASSFILE\5984#2.SDF JOB TITLE: GADZUK RESIDENCE PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 14 -24.0 1.291 PL 22.00 PF 2.0 S2 2.0 0.0 53.9 0.0 5.9 150 FTG 5E PE 2.2 S1 -3.0 0.0 58.0 0.0 0.044 TL 44.50 PV 0.2 Pipe: 15 -24.0 1.250 PL 48.00 PF 2.5 S1 -3.0 0.0 58.0 0.0 6.3 150 FTG ---- PE 0.0 M1 -3.0 0.0 60.4 0.0 0.051 TL 48.00 PV 0.3 Pipe: 16 FIXED PRESSURE LOSS DEVICE M2 -3.0 0.0 64.4 0.0 4.0 psi, 24.0 gpm M1 -3.0 0.0 60.4 0.0 Pipe: 17 -24.0 1.291 PL 300.00 PF 13.5 M2 -3.0 0.0 64.4 0.0 5.9 150 FTG B PE 0.0 SRC -3.0 SRCE 78.0 (N/A) 0.044 TL 308.00 PV 0.2 NOTES: (1) Calculations were performed by the HASS 7.3 computer program under license no. 5009058210 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 (2) The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.005 gpm. (3) Velocity pressures are printed for information only and are not used in balancing the system. Maximum water velocity is 8.8 ft/sec at pipe 11. (4) PIPE FITTINGS TABLE Pipe Table Name: FSW-STD.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVly BfyVly GatVly AlmChk DPV1v NPTee 1.380 3.00 6.00 2.00 7.00 6.00 1.00 10.00 10.00 6.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 ' DATE: 8/22/2001 D:\HASSFILE\5984#2.SDF JOB TITLE: GADZUK RESIDENCE PAGE: A Diameter (in) 1.380 PAGE: F Diameter (in) 1.101 1.394 PAGE: I Diameter (in) 1.055 1.291 MATERIAL: SCH40 Equivalent E T L Ell Tee LngEll 3.00 6.00 2.00 MATERIAL: CPVC Equivalent E T L Ell Tee LNG -EL 7.00 5.00 0.10 8.00 6.00 0.10 MATERIAL: Copper Equivalent E T C Ell Tee ChkVly 3.00 7.50 7.60 4.50 9.10 10.60 HWC: 120 Fitting Lengths in Feet C B G A D ChkV1v BfyVly GatVly AlmChk DPV1v 7.00 6.00 1.00 10.00 10.00 HWC: 150 Fitting Lengths in Feet C B G A D CHKVLV BFYVLV GT-VLV ALMVLV DRYVLV 0.10 0.10 0.10 0.00 0.00 0.10 0.10 0.10 0.00 0.00 HWC: 150 Fitting Lengths in Feet B BfyVly 8.00 8.00 DATE: 8/22/2001 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 D:\HASSFILE\5984#2.SDF JOB TITLE: GADZUK RESIDENCE WATER SUPPLY ANALYSIS 100.0 80. Static: 92.00 psi Resid: 20.00 psi Flow: 1700.0 gpm G A U G E 60.0 P R E S S U R 40.0 _ E P s i 20.0 0.0 -14.7 400600 800 1000 1200 1400 1600 1800 2000 FLOW (GPM) LEGEND Available pressure 91.97 psi @ 24.0 gpm Required pressure 77.96 psi @ 24.0 gpm FIRE SYSTEMS WEST 219 FRONTAGE ROAD NORTH, SUITE B PACIFIC, WA 98047 (253) 833-1248 HYDRAULIC CALCULATIONS FOR GADZUK RESIDENCE 4815 SOUTH 146TH STREET TUKWILA, WA 98168 FILE NUMBER: 5984#2 DATE: NOV 21, 2001 -DESIGN DATA - OCCUPANCY CLASSIFICATION: NFPA 13D (1 Head Calculation) DENSITY: 0 gpm/sprinkler AREA OF APPLICATION: MASTER SUITE COVERAGE PER SPRINKLER: 18' X 18' Maximum NUMBER OF SPRINKLERS CALCULATED: 1 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 13.0 gpm TOTAL WATER REQUIRED (including hose): 13.0 gpm FLOW AND PRESSURE (@ BOR): 13.0 GPM @ 33.9 PSI SPRINKLER ORIFICE SIZE: 3/8 inch NAME OF CONTRACTOR: FIRE SYSTEMS WEST, INC. DESIGN/LAYOUT BY: JIM STEWART AUTHORITY HAVING JURISDICTION: TUKWILA FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: FIRE SWI 140B1 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 0 I5825A ) HRS SYSTEMS, INC. ATLANTA, GA DATE: 11/21/2001 JOB TITLE: GADZUK RESIDENCE WATER SUPPLY DATA SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 D:\HASSFILE\5984#2.SDF SOURCE STATIC RESID. FLOW AVAIL. TOTAL RE¢'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SRC 92.0 20.0 1700.0 92.0 13.0 46.8 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE TOTAL HOSE STREAM ALLOWANCE AT SOURCE OTHER HOSE STREAM ALLOWANCES TOTAL DISCHARGE FROM ACTIVE SPRINKLERS NODE ANALYSIS DATA 13.0 GPM 0.0 GPM 0.0 GPM 13.0 GPM NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 22.0 K= 3.00 18.8 13.0 2 22.0 - - - - 19.2 - - - A 22.0 19.2 B 22.0 19.4 C 12.0 23.9 D 12.0 24.0 E 4.0 27.8 TOR 12.0 24.1 BOR 2.0 33.9 BF1 3.5 28.2 BF2 3.5 33.2 S1 -3.0 - - - 37.7 S2 2.0 34.9 S3 2.0 34.6 S4 2.0 34.2 M1 -3.0 38.5 M2 -3.0 - - 42.5 SRC -3.0 SOURCE 46.8 13.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 11/21/2001 D:\HASSFILE\5984#2.SDF JOB TITLE: GADZUK RESIDENCE PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -13.0 1.101 PL 7.50 PF 0.4 1 22.0 3.0 18.8 13.0 4.4 150 FTG T PE 0.0 A 22.0 0.0 19.2 0.0 0.031 TL 12.50 PV 0.1 Pipe: 2 0.0 1.101 PL 5.00 PF 0.0 2 22.0 0.0 19.2 0.0 0.0 150 FTG T PE 0.0 A 22.0 0.0 19.2 0.0 0.000 TL 10.00 PV 0.0 Pipe: 3 -13.0 1.394 PL 20.00 PF 0.3 A 22.0 0.0 19.2 0.0 2.7 150 FTG T PE 0.0 B 22.0 0.0 19.4 0.0 0.010 TL 26.00 PV 0.1 Pipe: 4 -13.0 1.394 PL 10.00 PF 0.2 B 22.0 0.0 19.4 0.0 2.7 150 FTG T PE 4.3 C 12.0 0.0 23.9 0.0 0.010 TL 16.00 PV 0.1 Pipe: 5 -13.0 1.394 PL 5.25 PF 0.1 C 12.0 0.0 23.9 0.0 2.7 150 FTG T PE 0.0 D 12.0 0.0 24.0 0.0 0.010 TL 11.25 PV 0.1 Pipe: 6 -13.0 1.394 PL 4.50 PF 0.0 D 12.0 0.0 24.0 0.0 2.7 150 FTG ---- PE 0.0 TOR 12.0 0.0 24.1 0.0 0.010 TL 4.50 PV 0.1 Pipe: 7 -13.0 1.380 PL 9.50 PF 0.2 TOR 12.0 0.0 24.1 0.0 2.8 120 FTG T PE 3.5 E 4.0 0.0 27.8 0.0 0.015 TL 15.50 PV 0.1 Pipe: 8 -13.0 1.380 PL 2.00 PF 0.2 E 4.0 0.0 27.8 0.0 2.8 120 FTG CB PE 0.2 BF1 3.5 0.0 28.2 0.0 0.015 TL 15.00 PV 0.1 Pipe: 9 FIXED PRESSURE LOSS DEVICE BF2 3.5 0.0 33.2 0.0 5.0 psi, 13.0 gpm BF1 3.5 0.0 28.2 0.0 Pipe: 10 -13.0 1.055 PL 1.50 PF 0.1 BF2 3.5 0.0 33.2 0.0 4.8 150 FTG ---- PE 0.6 BOR 2.0 0.0 33.9 0.0 0.038 TL 1.50 PV 0.2 Pipe: 11 -13.0 1.055 PL 2.00 PF 0.3 BOR 2.0 0.0 33.9 0.0 4.8 150 FTG 2E PE 0.0 S4 2.0 0.0 34.2 0.0 0.038 TL 8.00 PV 0.2 Pipe: 12 -13.0 1.291 PL 12.00 PF 0.4 S4 2.0 0.0 34.2 0.0 3.2 150 FTG 3E PE 0.0 S3 2.0 0.0 34.6 0.0 0.014 TL 25.50 PV 0.1 Pipe: 13 -13.0 1.291 PL 2.00 PF 0.3 S3 2.0 0.0 34.6 0.0 3.2 150 FTG CB PE 0.0 S2 2.0 0.0 34.9 0.0 0.014 TL 20.60 PV 0.1 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 11/21/2001 D:\HASSFILE\5984#2.SDF JOB TITLE: GADZUK RESIDENCE PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 14 -13.0 1.291 PL 22.00 PF 0.6 S2 2.0 0.0 34.9 0.0 3.2 150 FTG 5E PE 2.2 S1 -3.0 0.0 37.7 0.0 0.014 TL 44.50 PV 0.1 Pipe: 15 -13.0 1.250 PL 48.00 PF 0.8 S1 -3.0 0.0 37.7 0.0 3.4 150 FTG ---- PE 0.0 M1 -3.0 0.0 38.5 0.0 0.017 TL 48.00 PV 0.1 Pipe: 16 FIXED PRESSURE LOSS DEVICE M2 -3.0 0.0 42.5 0.0 4.0 psi, 13.0 gpm M1 -3.0 0.0 38.5 0.0 Pipe: 17 -13.0 1.291 PL 300.00 PF 4.4 M2 -3.0 0.0 42.5 0.0 3.2 150 FTG B PE 0.0 SRC -3.0 SRCE 46.8 (N/A) 0.014 TL 308.00 PV 0.1 NOTES: (1) Calculations were performed by the HASS 7.3 computer program under license no. 5009058210 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 (2) The system has been calculated to provide an average imbalance at each node of 0.006 gpm and a maximum imbalance at any node of 0.094 gpm. (3) Velocity pressures are printed for information only and are not used in balancing the system. Maximum water velocity is 4.8 ft/sec at pipe 10. (4) PIPE FITTINGS TABLE Pipe Table Name: FSW-STD.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkV1v BfyVly GatV1v AlmChk DPV1v NPTee 1.380 3.00 6.00 2.00 7.00 6.00 1.00 10.00 10.00 6.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 11/21/2001 D:\HASSFILE\5984#2.SDF JOB TITLE: GADZUK RESIDENCE PAGE: A Diameter (in) 1.380 PAGE: F Diameter (in) 1.101 1.394 PAGE: I Diameter (in) 1.055 1.291 MATERIAL: SCH40 Equivalent E T L Ell Tee LngEll 3.00 6.00 2.00 MATERIAL: CPVC Equivalent E T L Ell Tee LNG -EL 7.00 5.00 0.10 8.00 6.00 0.10 MATERIAL: Copper Equivalent E T C Ell Tee ChkVly 3.00 7.50 7.60 4.50 9.10 10.60 HWC: 120 Fitting Lengths in Feet C B G A ChkVly BfyVly GatV1v AlmChk 7.00 6.00 1.00 10.00 D DPV1v 10.00 HWC: 150 Fitting Lengths in Feet C B G A D CHKVLV BFYVLV GT-VLV ALMVLV DRYVLV 0.10 0.10 0.10 0.00 0.00 0.10 0.10 0.10 0.00 0.00 HWC: 150 Fitting Lengths in Feet B BfyVly 8.00 8.00 DATE: 11/21/2001 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 D:\HASSFILE\5984#2.SDF JOB TITLE: GADZUK RESIDENCE WATER SUPPLY ANALYSIS Static: 92.00 psi Resid: 20.00 psi Flow: 1700.0 gpm 100.0 1 G 80.0 G A U G E 60.0 P R E S 2 S U R 40.0 E P s i 20.0 0.0 -14.7 2 400600 800 1000 1200 1400 1600 1800 2000 FLOW (GPM) LEGEND Available pressure 91.99 psi @ 13.0 gpm M Required pressure 46.82 psi @ 13.0 gpm FIRE SYSTEMS WEST 219 FRONTAGE ROAD NORTH, SUITE B PACIFIC, WA 98047 (253) 833-1248 HYDRAULIC CALCULATIONS FOR GADZUK RESIDENCE 4815 SOUTH 146TH STREET TUKWILA, WA 98168 FILE NUMBER: 5984#1 DATE: NOV 21, 2001 -DESIGN DATA - OCCUPANCY CLASSIFICATION: NFPA 13D (2 Head Calculation) DENSITY: gpm/sprinkler AREA OF APPLICATION: MASTER SUITE COVERAGE PER SPRINKLER: 18' X 18' Maximum NUMBER OF SPRINKLERS CALCULATED: 2 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 26.0 gpm TOTAL WATER REQUIRED (including hose): 26.0 gpm FLOW AND PRESSURE (@ BOR): 26.0 GPM ® 36.8 PSI SPRINKLER ORIFICE SIZE: 3/8 inch NAME OF CONTRACTOR: FIRE SYSTEMS WEST, INC. DESIGN/LAYOUT BY: JIM STEWART AUTHORITY HAVING JURISDICTION: TUKWILA FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: FIRE SWI 140B1 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 0 I5825A ) HRS SYSTEMS, INC. ATLANTA, GA SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 11/21/2001 JOB TITLE: GADZUK RESIDENCE WATER SUPPLY DATA D:\HASSFILE\5984#1.SDF SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SRC 92.0 20.0 1700.0 92.0 26.0 67.2 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE TOTAL HOSE STREAM ALLOWANCE AT SOURCE OTHER HOSE STREAM ALLOWANCES TOTAL DISCHARGE FROM ACTIVE SPRINKLERS NODE ANALYSIS DATA 26.0 GPM 0.0 GPM 0.0 GPM 26.0 GPM NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 22.0 K= 3.00 18.8 13.0 2 22.0 K= 3.00 18.9 13.0 A 22.0 19.2 B 22.0 20.1 C 12.0 25.0 D 12.0 25.4 E 4.0 29.9 TOR 12.0 25.5 BOR 2.0 36.8 BF1 3.5 30.9 BF2 3.5 35.9 S1 -3.0 44.6 S2 2.0 40.2 S3 2.0 39.2 S4 2.0 37.9 M1 -3.0 47.5 M2 -3.0 - - - - 51.5 SRC -3.0 SOURCE 67.2 26.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 11/21/2001 D:\HASSFILE\5984#1.SDF JOB TITLE: GADZUK RESIDENCE PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -13.0 1.101 PL 7.50 PF 0.4 1 22.0 3.0 18.8 13.0 4.4 150 FTG T PE 0.0 A 22.0 0.0 19.2 0.0 0.031 TL 12.50 PV 0.1 Pipe: 2 -13.0 1.101 PL 5.00 PF 0.3 2 22.0 3.0 18.9 13.0 4.4 150 FTG T PE 0.0 A 22.0 0.0 19.2 0.0 0.031 TL 10.00 PV 0.1 Pipe: 3 -26.0 1.394 PL 20.00 PF ' 0.9 A 22.0 0.0 19.2 0.0 5.5 150 FTG T PE 0.0 B 22.0 0.0 20.1 0.0 0.035 TL 26.00 PV 0.2 Pipe: 4 -26.0 1.394 PL 10.00 PF 0.6 B 22.0 0.0 20.1 0.0 5.5 150 FTG T PE 4.3 C 12.0 0.0 25.0 0.0 0.035 TL 16.00 PV 0.2 Pipe: 5 -26.0 1.394 PL 5.25 PF 0.4 C 12.0 0.0 25.0 0.0 5.5 150 FTG T PE 0.0 D 12.0 0.0 25.4 0.0 0.035 TL 11.25 PV 0.2 Pipe: 6 -26.0 1.394 PL 4.50 PF 0.2 D 12.0 0.0 25.4 0.0 5.5 150 FTG ---- PE 0.0 TOR 12.0 0.0 25.5 0.0 0.035 TL 4.50 PV 0.2 Pipe: 7 -26.0 1.380 PL 9.50 PF 0.9 TOR 12.0 0.0 25.5 0.0 5.6 120 FTG T :PE 3.5 E 4.0 0.0 29.9 0.0 0.056 TL 15.50 PV 0.2 Pipe: 8 -26.0 1.380 PL 2.00 PF 0.8 E 4.0 0.0 29.9 0.0 5.6 120 FTG CB PE 0.2 BF1 3.5 0.0 30.9 0.0 0.056 TL 15.00 PV 0.2 Pipe: 9 FIXED PRESSURE LOSS DEVICE BF2 3.5 0.0 35.9 0.0 5.0 psi, 26.0 gpm BF1 3.5 0.0 30.9 0.0 Pipe: 10 -26.0 1.055 PL 1.50 PF 0.2 BF2 3.5 0.0 35.9 0.0 9.6 150 FTG ---- PE 0.6 BOR 2.0 0.0 36.8 0.0 0.136 TL 1.50 PV 0.6 Pipe: 11 -26.0 1.055 PL 2.00 PF 1.1 BOR 2.0 0.0 36.8 0.0 9.6 150 FTG 2E PE 0.0 S4 2.0 0.0 37.9 0.0 0.136 TL 8.00 PV 0.6 Pipe: 12 -26.0 1.291 PL 12.00 PF 1.3 S4 2.0 0.0 37.9 0.0 6.4 150 FTG 3E PE 0.0 S3 2.0 0.0 39.2 0.0 0.051 TL 25.50 PV 0.3 Pipe: 13 -26.0 1.291 PL 2.00 PF 1.1 S3 2.0 0.0 39.2 0.0 6.4 150 FTG CB PE 0.0 S2 2.0 0.0 40.2 0.0 0.051 TL 20.60 PV 0.3 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 11/21/2001 D:\HASSFILE\5984#1.SDF ,, JOB TITLE: GADZUK RESIDENCE PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 14 -.26.0 1.291 PL 22.00 PF 2.3 S2 2.0 0.0 40.2 0.0 6.4 150 FTG 5E PE 2.2 S1 -3.0 0.0 44.6 0.0 0.051 TL 44.50 PV 0.3 Pipe: 15 -26.0 1.250 PL 48.00 PF 2.9 S1 -3.0 0.0 44.6 0.0 6.8 150 FTG ---- PE 0.0 M1 -3.0 0.0 47.5 0.0 0.060 TL 48.00 PV 0.3 Pipe: 16 FIXED PRESSURE LOSS DEVICE M2 -3.0 0.0 51.5 0.0 4.0 psi, 26.0 gpm M1 -3.0 0.0 47.5 0.0 Pipe: 17 -26.0 1.291 PL 300.00 PF 15.7 M2 -3.0 0.0 51.5 0.0 6.4 150 FTG B PE 0.0 SRC -3.0 SRCE 67.2 (N/A) 0.051 TL 308.00 PV 0.3 NOTES: (1) Calculations were performed by the HASS 7.3 computer program under license no. 5009058210 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 (2) The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.011 gpm. (3) Velocity pressures are printed for information only and are not used in balancing the system. Maximum water velocity is 9.6 ft/sec at pipe 11. (4) PIPE FITTINGS TABLE Pipe Table Name: FSW-STD.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkV1v BfyVly GatV1v AlmChk DPV1v NPTee 1.380 3.00 6.00 2.00 7.00 6.00 1.00 10.00 10.00 6.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 11/21/2001 D:\HASSFILE\5984#1.SDF JOB TITLE: GADZUK RESIDENCE PAGE: A Diameter (in) 1.380 PAGE: F Diameter (in) 1.101 1.394 PAGE: I Diameter (in) 1.055 1.291 MATERIAL: SCH40 Equivalent E T L Ell Tee LngEll 3.00 6.00 2.00 MATERIAL: CPVC Equivalent E T L Ell Tee LNG -EL 7.00 5.00 0.10 8.00 6.00 0.10 HWC: 120 Fitting Lengths in Feet C B G A D ChkVly BfyVly GatV1v AlmChk DPV1v 7.00 6.00 1.00 10.00 10.00 HWC: 150 Fitting Lengths in Feet C B G A D CHKVLV BFYVLV GT-VLV ALMVLV DRYVLV 0.10 0.10 0.10 0.00 0.00 0.10 0.10 0.10 0.00 0.00 MATERIAL: Copper HWC: 150 Equivalent Fitting Lengths E T C B Ell Tee ChkV1v BfyVly 3.00 7.50 7.60 8.00 4.50 9.10 10.60 8.00 in Feet DATE: 11/21/2001 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 D:\HASSFILE\5984#1.SDF JOB TITLE: GADZUK RESIDENCE WATER SUPPLY ANALYSIS Static: 92.00 psi Resid: 20.00 psi Flow: 1700.0 gpm G A U G E 60.0 _ P R E S S U R 40.0 _ E P s i 20.0 _ 100.0 80.0 _ 0.0 -14.7 1 400600 800 1000 1200 1400 1600 1800 2000 FLOW (GPM) LEGEND Available pressure 91.97 psi @ 26.0 gpm Required pressure 67.21 psi @ 26.0 gpm alb DINING KITCHEN IF 0 W 11/4" PVC 114" PVC 114" PVC 0 TOILET -D J a 0 U n7� �JQ GARAGE i T 114" " COPPERp . D SL X TH 114" GREAT ROOM - '1 I r FIRST FLOOR FIRE SPRINKLER PLAN SCALE 1/4" = 1 SPRINKLER SPACING TABLE - RESIDENTIAL PENDENT GEM MODEL jF68O- 3/8" ORIFICE PIPE SIZED CALC'D USING THIS SPACING SPRINKLER SPACING MLAx SPRNKLER LOCATION MAX. (FROM SIDE WALLS) SPRNKLER DESIGN DISCHARGE K -FACTOR SMGI.E SPRK 1W0 OR MORE SPRKS PLAN SYMBOL FEET FEET ` GPM 0 PSI GPM 0 PSI U S 0 18 X 18 - 9 130 0 188 13 0 188 30 4 11/4" REST -RISER 11/4" BACKFLOW _ AMES 2000B FITTER NOTE. FSW TO INSTALL (2) PRESSURE GAUGES AS SHOWN ON FINISHED FLOOR V� UNION `Q 6. a i SL X TH TO DRAIN F2 1 RISER 0-6 BRASS BRASS ELL - sE§ 1' WATER FLOW INFO STATIC PRESSURE: 92 PSG RESIDUAL' PRESSURE: 20 PSI FLOW. 1700 GPM DATE LOCATION PER MARK - KING COUNTY WATER DISTRICT 1125 (206) 242-9547 1 RISER SECTION SCALE. 1/2P = 1 SITE VICINITY -MAP NO SCALE CONTRACT NAME PETER & DIANNE GADZUK RESIDENCE 4815 SOUTH 146TH STREET TUKWILA, WA 98168 CONTRACT WITH ARCADY HOMES ADDRESS CITY/STATE (206) 870-7221 HANGE R LEGEND SPRINKLER LEGEND SPRINKLER HEADS REVISIONS GENERAL NOTES DESIGN CRITERIA AND NOTES e c 'I; KY -iw v 'C CL.AM.' TCP G+ M ci 4 */DE PPM, 5' PA) W -i,MME TP_Fr_ALf.L1 PDX! TC'4.E NUT SPKR THIES. SPRINTER earn SIZES AND TtPE UPRIGHT PEND. TEE SITE SYMBOL TYPE MFG MODEL SIZE TEMP FINISH CANOPY QUANTITY MK DATE BY DESCRIPTION 0 SSP GEM F680 3/8" 155E WHITE REC WHT 14 9-4-01 JS AS BUILT P QW)E.R tRP1 J1 Sr v R tit 5/16' 3/3 1/1( 1/2' SPRAY SSU GEM A—QR 1/2" 200'F BRASS N JA 1 A '11-21-01 JS AS BUILT FOR SEMI—RECESSED HEADS A -o 1" s i11.{91-1 SF' , L T u APPROVALS REQUIRED - DISTRIBUTION TUKWILA FIRE DEPARTMENT TUKWILA FIRE DEPARTMENT - 1 sEf 29N YtT tr 1 OWNER/ARCHITECT OWNER/ARCHITECT 2 TEMP RATNG 0 155" b s _ !s # is ai FIRE SYSTEMS WEST 2 TOTAL THIS SHEET +.D r aT -3r 15 i - TOTAL 5 1 ALL WJERW.. AND EQt$'1iENT TO BE NEW ANO UNDERWRITERS APPROVED. 2. PIPING DIMENSIONS ME CENTER TO CENTER EXCEPT RISER & DIMENSICNS SHOWN THUSLY (t-6) M1UCH ARE END TO END 3. EARTHQUAKE BRACING SHALL BE PROVIDED N ACCORDAt4CE LITD4 NIT'A PAMPHLET NO. 13. 4 PIPE HANGERS AND IETHOQ OF HANGING TO BE IN LANCE NTH NFPA PAMPHLET NO 13. 5 PIPING SHALL BE IN ACCORDANCE MPTH NEPA PNIPHLET NO 13. a JOINING OF PIPE AND FITTINGS, THREADED AND WELDED SHALL BE N ACCORDANCE WITH NEPA PAMPHLET NO 13. 7 OWNER TO PRINCE ADEQUATE HEAT 10 PREVENT WATER N PIPES FROM FREEZING N AREAS PROTECTED BY A WET PPE SPRINKLER SYSTEM. & STRUCTURAL ADEQUACY Of THE BUILDING TO SUPPORT THE SPRINKLER - PIPING IS THE RESPONSIBILITY OF THE OWNER APC/OR HITS STRUCTURAL REPRESD4TATNE. - - 1. THIS SYSTEM HAS BEEN DESIGNED PER NFPA 13D 2. AIL PIPE TO BE 1" CENTRAL BLAZEMASTER CPVC W/ SPEARS CPUC FITTINGS UNLESS NOTED OTHERWISE. 3 - PPE SHOWN WITH DIAMETER AND LENGTH TO BE AWED SCHEDULE 40 STEEL. - ICs t ___Ihz 1 Fire Systems West -219 Frontage Road North, suite B Pacific, WA 98047 (253) 833-1248_ fax' (253) 735-0113 WA CL IIFlRESWI 14081 Q C. FAS BY DENNIS SMITH Q C INSTALL BY' i l DESIGNER - JM STEWART 4 DATE JOB NO = AUGUST 17, 2001 1-02-16-5984 • t— SHEET - 1 OF 2 } CPVC DOUBLE FASTENER STRAP TYPE HANGER HANGER NO. 24 CPVC HANGER 'C' BATH LLJ J 0 F— CLOSET, m CLOSET 114 SUITE 0 m BATH OFFICE A a 1 V4 BED ROOM LAUNDRY m 1V4 0 J BED ROOM SECOND FLOOR FIRE SPRINKLER PLAN SCALE 1/4" = 1'-0" _SPRINKLER SPACING TABLE - RESIDENTIAL PENDENT GEM MODEL IF680- - 3/8" ORIFICE PIPE SIZED CALM USING THIS SPACING SPRINKLER SPACING MAX. -SPRINKLER LOCATION MAX. (FROM SIDE WAN.LS) SPRINKLER DESIGN DISCHARGE K -FACTOR SINGLE SPRK TWO OR MORE SPRITS PLAN SYMBOL FEET - FEET GPM 0 PSI GPM 0 PSI U.S. 0 18 X 18 9 130 0 188 13 0 188 - 30 • • • • .s CONTRACT NAME. PETER & DIANNE GADZUK RESIDENCE 4815 SOUTH 146TH STREET TUKWILA, WA 98168 CONTRACT WITH. ARCADY HOMES - ADDRESS CITY/STATE (206) 870-7221 - HANGER LEGEND SPRINKLER LEGEND SPRINKLER HEADS REVISIONS 1 GENERAL NOTES DESIGN CRITERIA AND NOTES i Lro E C:] '+ s_S+ 'i 11,1 - _ aH t:W=.. #' T SPKR TMS SPRINKLER _ MO X117 _ SIZES UPRIGHT PEND. TEE SIZE SYMBOL -TYPE MFG MODEL SIZE - TEMP. FINISH - CANOPY QUANTITY MK DATE BY DESCRIPTION SSP GEM F680 3/8 155T CONCEALED WHITE 14 A 9-4-01 JS AS BUILT D TCP EtrA-C:fIan *%71:AF P rf.'Wrn 7:ir":44 rtt Rria -xjc_ ,-.-)c in, 5/10 3/C 7/1C 1/2" SPRAY 0 11-21-01 JS AS BUILT FOR SEMI—RECESSED HEADS 0 r 0 FltAri Seat r r1A¢ u APPROVALS REQUIRED = DISTRIBUTION TUKWIIA FIRE DEPARTMENT TUKWILA FIRE DEPARTMENT 1 H -Six4 M - J "J• ec&.1 OWNER/ARCHITECT . " OWNER/ARCHITECT - TEMP - RATING 0` _155_ FIRE SYSTEMS WEST 2 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UNDERWRITERS APPROVED 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXIT RISER & DIMENSIONS SHOWN THUSLY (1-6) WHICH ARE END TO END. 3. EARTHQUAKE BRACING Stall BE PROVIDED IN ACCORDANCE WITH NFPA PAMPHZT NO. 13. - 4 PIPE HANGERS AND METHOD OF HANGING TO 8E N ACCORDANCE WITH _ NEPA PAMPHIST NO 13. 5. PIPING SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13. 6. JOINING OF PIPE AND FITTINGS, BREADED AND WELDED SHALL BE N - ACC0RDANCE WITH NEPA PAMPHLET NO. -13. - 7. OWNER TO PROM( ADE0I1ATE HEAT TO PREVENT WATER N PIPES FROM FREEZING N AREAS PROTECTED BY A WET PIPE SPRIMQER SYSTEM. & STRUCTURAL ADEQUACY OF THE BIJLDNG TO SUPPORT THE SPRINKLER PIPING IS THE RESPONSIB@JIY OF THE OWNER AND/OR HIS STRUCTURAL 2 REPRESENTATIVE TOTAL THIS SHEET 14 1 TOTAL- _- 1 5 1. THUS SYSTEM HAS BEEN DESIGNED PER NFPA 130. - 2ALC PIPE TO BE 1" CENTRAL BLAZEMASTER CPVC W/ SPEARS CPUC FITTINGS UNLESS NOTED OTHERWISE. 3. PIPE SHOWN WITH DIAMETER AND LENGTH TO BE AWED SCHEDULE 40 STEEL Fire Systems. West _ 219 Frontage Road " North, suite 8 Pacific, - WA 98047 - - - (253) 833-1248 ,fax: (253) 735-0113 - WA_ i i /FlRESWI 4081: O.G. FAB BY: DENNIS SMITH O.C. INSTALL BY: DESIGNER JW1 STEWART DATE -" AUGUST 17 2001 JOB NO. -02-16-5084 SHEET - 2OF2 = $9 r- zs� 1Y" PVC Lr S1 0 DINING KITCHEN `3" -D TOILET J 4t JQ • GARAGE 1V4 COPPER 11/4" SL JQ { GREAT ROOM t • 11/4" PVC LJ 1 FIRST FLOOR FIRE SPRINKLER PLAN SCALE: 1/4" = 1'—(Y i SPRINKLER SPACING TABLE - RESIDENTIAL PENDENT GEM MODEL #F978- 3/8" ORIFICE PPE SIZED CALC'D USING THIS SPACING SPRUdGDt SPACING IMAx. SPRINKLER LOCATION MAX (FROM SIDE ,MALTS) SPRINKLER DEIGN DISCHARGE K -FACTOR SINGLE SPRX. NO OR BORE sPRKS PLAN SYMBOL - FEET FEET GPM 0 PSI,GPM 0 PSI U.S 0 18 X 18 - 9 24.0032. 170164 4.2 4' F Al 114 PVC O (J) I SOCK -IT TEE 11/4" RESI-RISER 11/4" BACKFLOW AMES 2000B FITTER NOTE: FSW TO INSTALL (2) PRESSURE GAUGES AS SHOWN ON RISER FINISHED FLOOR WATER FLOW INFO STATIC PRESSURE: 92 PSIG RESIDUAL PRESSURE: 20 PSI FLOW: 1700 GPM DATE: LOCATION: PER: MARK - KING COUNTY WATER DISTRICT #125 (206) 242-9547 \ R \a *(Z5k UNION 7 I'Ti/1 1J 1 CD >a F ,.r 1 0-6 BRASS ASS ELL RISER SECTION SCALE: 1/2" - 1'-0r' �V) 1< 1< FILE SL X TH TO DRAIN 1 0 ACCEPTED Without Comments As Noted In Red Per The Attached Letter ;These These plans have been reviewed by The Tukwila Fire 'revention Bureau for conformance with current city standards. Acceptance is subject to errors and :.missions which do not authorize violations of adopted .t2ndards and ordinances. The responsibility for the dequacy of design rests totally with the designer. ' dditions, deletions or revisions to these drawings after } nis date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. 4 Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date. T( St 1 01 By S(0 rUKWILA FIRE DEPARTMENT Please call: 575.4407 and give this job No. and exact address for shut, down or restoration apdroval. P. ti S 42ND AVE S 46TH AVE S SITE' V) VICINITY MAP, NO SCALE CONTRACT NAME: PETER & DIANNE GADZUK RESIDENCE 4815 SOUTH 146TH STREET TUKWILA, WA 98168 CONTRACT WITH. ARCADY HOMES ADDRESS - CITY/STATE (206) 870-7221 HANGER LEGEND WK-vi C - TTP Mkt( STF4 &•3;E r SPKR THRDS. SPRINKLER Own Sas AND TYPE SPRIN UPRIGHT KLER LE PEND. GEND TEE SIZE E PrE PCD I/t s/RS_3/87/i$ 1/? SPWLY SYMBOL TYPE MFG SPRINKLER HEADS MODEL - SIZE - TEMP. FINISH CANOPY QUANTITY MK DATE I BY REVISIONS DESCRIPTION GENERAL NOTES DESIGN CRITERIA AND NOTES kr w3.E 0 -0- SSP SSU GEN - GEM F978 A—QR 3/8' 1/2" 155F 200'F CONCEALED BRASS WHITE N/A 14 1 A A A 0 r F T CZ F'iAN E Var A APPROVALS REQUIRED - DISTRIBUTION TUKWILA FlREI DEPARTMENT TUKWILA FIRE DEPARTMENT 1 r SKiE �i 6r x OWNER/ARCHITECT OWNER/ARCHITECT = TE RATING Q 155' FIRE SYSTEMS WEST 2 2 win c.5r 5 TOTAL THIS SHEET 15 - TOTAL 1. ALL 1JATERIAL AND EQUPMFM TO BE NEW AND UNDERWRITERS APPROVED. 2. PPING D6 ZNS10S ARS CENTER TO CENTER EXCEPT RISER & DI(NSIOtS SHOWN THUSLY (1-6) 16i1CH ARE END TO END. 3. EARTHQLW(E BRACING SHALL BE PRWIDED N ACCORDANCE *Pr NFPA PAMPHLET N0. 13. 4. PPE HANGERS AND METHOD OF HANGING TO BE N ACCORDANCE MATH NFPA PAMPHLET N0. 13. 5. PIPING SHALL BE N ACCORDANCE WITH NEPA PALIPHLET N0. 13. 6. JOINING OF PIPE AND FITTINGS, THREADED AND WELDED SHALL OE N ACCORDANCE MATH NEPA PAMPHLET No. 13. 7. OWNER TO PROVIDE ADEQUATE NEAT TO PREVENT NAIER N PIPES FROM FREEZING N AREAS PR0►tL:IW BY A KT PIPE SPRINKLER SYSTEM. - 8. STRUCTURAL ADEQUACY OF THE MAIM TO SUPPORT THE SPRINKLER - PPNG iS THE RESPONS1B1U1Y OF,THE OWNER AND/OR HIS STRUCTURAL REPRESENTATIVE - - 1. THIS SYSTEM HAS BEEN DESIGNED PER NEPA 13D. 2. ALL PIPE TO BE 1" CENTRAL BLAZEMASTER CPVC W/ SPEARS CPUC FIRINGS UNLESS NOTED OTHERWISE. 3. PIPE SHOWN WITH DIAMETER AND LENGTH TO BE AWED SCHEDULE 40 STEEL Fire Systems West 219 Frontage Road North, suite B Pacific, WA 98047 (253) 833-1248 fox: (253) 735-0113 WA CL 1FIRESWI 14081 Q.G. FAB BY: DENNIS SMITH Q C. INSTALL 8Y: / / DESIGNER DATE JOB N0. SHEET JM STEWART AUG 3 Jut) -02-16-5984 - 1 OF 2 1 2/1th0 ;�'!l 1 R 1 FIG. 126 LAG BOLT CPVC'DOUBLE FASTENER STRAP TYPE HANGER HANGER NO. 24 CPVC HANGER 'C' CENTRAL "NO BLOCK" HANGER 'D' CPVC SINGLE FASTENER STRAP TYPE HANGER HANGER NO. 22 CPVC HANGER 'A' FIG. 126 LAG BOLT CPUC DOUBLE FASTENER STRAP TYPE HANGER HANGER NO 23 CPVC HANGER 'B' • • BATH F— W —J0 • CLOSET SUITE o• CLOSET 114 0 0 OFFICE LAUNDRY 114 • •o BATH BED ROOM 0 0 -I- o 0 U r- 0 BED ROOM SECOND FLOOR FIRE SPRINKLER PLAN SCALE. 1 /4" = 1'-O" t SPRINKLER SPACING TABLE — RESIDENTIAL PENDENT GEM MODEL #F978— 3/8" ORIFICE PpE SIZED CALC'0 USING THIS SPACING SPRINKLER SPAONG MAX SPRINKLER LOGT1ON MAX (FROM SDE WALLS) SPRINKLER DESIGN DISCHARGE K -FACTOR SINGLE SPRK. TWO OR MORE SPINS _ PLAN SYMBOL FEET GPN 0 PSI GPM 0 PSI US -.FEET • 18 X 18 9 240 0 327 17 0 164 42 d CONTRACT NAME. PETER & DIANNE GADZUK RESIDENCE 4815 SOUTH 146TH STREET TUKWILA, WA 98168 CONTRACT WITH. ARCADY HOMES ADDRESS CITY/STATE (206) 870-7221 HANGER LEGEND SPRINKLER LEGEND SPRINKLER HEADS REVISIONS GENERAL NOTES DESIGN CRITERIA AND NOTES A 'Lr✓ v do EV /4 Ca.4kP M f S .AP tt '0:T SPR RMS. SPRINKLER ORME SIZES AND Tt'PE UPRIGHT PEND TEE SZE SYMBOL TYPE MFG MODEL SIZE TEMP. FINISH CANOPY QUANTITY MK DATE BY DESCRIPTION 0 SSP GEN F978 3/8" 155F CONCEALED WHITE 14 A 1' f C'+E E 4► :)Clem'? :?AEN K '.vim t/? 5/18' sir 7/16' I/? SPRAY A A 1- 0 r A F i rte{ t4. T APPROVALS REQUIRED DISTRIBUTION TUKWILA ARE DEPARTMENT TUKWILA FIRE DEPARTMENT 1 r.f_ w J .11 OWNER/ARCHITECT OWNER/ARCHITECT 2 7 TEMP RATING 0 15S' FIRE SYSTEMS WEST 2 TOTAL THIS SHEET 14 TOTAL 5 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UNDERWRITERS APPROVED 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISER & DIMENSIONS SHOWN THUSLY (1-6) WHIR ARE END TO END. 3 EARTHQUAKE BRACMNG SHALL BE PROVIDED IN ACCORDANCE WITH NFPA PAMPHLET NO. 13. 4 PIPE HANGERS AND METHOD OF HANGING TO BE N ACCORDANCE WITH NFPA PAMPHLET NO 13. 5 PIPING SHALL BE N ACCORDANCE WITH NFPA PAMPHLET 140. 13. 6 JOINING OF PIPE AND FITTINGS. THREADED AND WELDED SHALL BE N ACCORDANCE WITH NFPA PAMPHLET 140. 13. 7. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER N4 PIPES FROM FREEZING IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM. 8. STRUCTURAL ADEQUACY OF THE BULDNG TO SUPPORT THE SPRINKLER PING IS THE RESPONSIBLITY OF THE OWNER AND/OR HIS SIRUCTURAL REPRESENTATNE. 1. THIS SYSTEM HAS BEEN DESIGNED PER NFPA 13D. 2. ALL PIPE TO BE 1" CENTRAL BLAZEMASTER CPVC W/ SPEARS CPVC FITTINGS UNLESS NOTED OTHERWISE. 3. PIPE SHOWN WITH DIAMETER AND LENGTH TO BE AWED SCHEDULE 40 STEEL. Fire Systems West 219 Frontage Road North, suite B Pacific, WA 98047 (253) 833-1248 fax: (253) 735-0113 WA CL jFIRESW1 14061 Q.C. FAB BY: DENNIS SMITH Q C. INSTALL BY: / / DESIGNER DATE - JOS NO. SHEET - JW STEWART AUGUST 17.. 2001 1-02-16-5984 20F2 -1 --