Loading...
HomeMy WebLinkAboutPP - 420 STRANDER BLVD - UNKNOWN - PERMITS AND PLANS420 STRANDER BLVD ASSOCIATED PERMITS 94-F-233 94-S-209 SECURITY SYSTEMS $nc. (206) 5354300 610 112TH ST. E., TACOMA, WA 98445 1-800-346-9250 11/44111.minumnik. SUBMITTALS FOR: SEARS "HOMELIFE" 420 STRANDER BLVD. TUKWILLA, WA 98108 ELECTRICAL CONTRACTOR AUBURN ELECTRIC P.O. BOX 624 AUBURN, WA 98071 (206) 939-9696 SUB—CONTRACTOR S & S SECURITY SYSTEMS, INC. 610 112TH ST E TACOMA, WA 98445 (206) 535-6300 4 TUKWILA FIRE DEPARTMENT Please call: 575-4407 and give this job No. TV F-233 and exact address for shut, down or restoration approval. RESIDENTIAL & COMMERCIAL SECURITY SYSTEMS n,Y.om„ '„1i"„ THF COMPI FTF LINE/167900 •I yl7 flqtr l) ii. •• iffAssli\ • -L F� p>d is NO P PERS( VI G.ARS UOf��L-IF- rl Exl.T 8"-y 1 1142,UST e�- Sa D• r p 1111.: l µsvcl- PAOPERT Y LINE -� SrRAIJP R 14UI,rVAR D s -r r L- A N sr.A4.a ; 1 =2,0-0 23"TTL° t4"a/ r, AOA 0' I -0 1 r~Po�T INC. 1 Al-ve \ -rKA11ST par C GeiLluel'.FLIntl2E oQ r 1 1 j, 1 1 1 r 12"TTI e 24" o/c 1 I 1 L -JZ --J .v TV JOIST SERIES 1. 3/8" coach screw rod (pilot hole req'd). The TJI/25 a limited to 1/4 inch lag screw (pilot hole req'd). 2 Ceiling flange with 2 -No. 18 X 1 112- wood screws (pill hole req'd). ALL OPEN WEB TRUSSES • , �.,_ „Tt ,I 5 2" LINE MAX. 1. Pipe trapeze. 2 Censer pipe hanger between Trusses (unless specilkally allowed for In truss design) NOTE pipe can be parallel or perpendicular to Trusses. 3. 3/8" diameter rod L3 4" LINE MAX. ALL OPEN WEB TRUSSES rC U 0 _11_11 0 I 1 3'8" hanger rod 2 Flange wllh 2 • no 18 X 1 1 2" wood screws (Center on TJL a TJW truss chord and one screw in each member of double chord Trusses) 3 Applications over wallboard increase screw length by wallboard thickness 4 2" LINE MAX (n, 1Y WAT' t4n71'42. 4,12 Lz,r F.D. C ---D(1 XVJ- 3Aio 3 ABaG.K.FLOW N// T-o.N Pri r0... 4'c4- L1 I-4 2-I P SER W»M PETALL ND F1.doK Vo" -rat eIG"0/G &"AL -IA 1 3/3a=. I - 51AIP *2 at -40 r --lea %L" = I'- O" (r' CerLaNb 0 ' 61101111111.11,161•011VYNYIND .1101•110.010•1141{4 011•01•1•11111111 4.11•11•4101.1101011 1011.111111011/111,111.1*111.1.4111111 E;xiS� corlpuTEf, CITY dc1/1-DING 7 TJI" JOIST SERIES L1 fl,"I, I. F 1 34. de C•Poaw rod 2 Conk M�,n al compliance tolePPA.t] w be nrenae le manufactory upon request Hanaer Mtal: R.L. Drake Co Inc Tosco Incorporated P.O. Bo. 3243 796 E Harrison SI. Bona, ID $3707 ' Corona, CA 91719 14" LINE MAX. I Slc.►FLA1 510:1• LJELDED 1Q Pim- C E.c. P rejr , 51ZLD PLAN FEEL) Ors, CROS MAIr-1 \ TOC(` FIG, IC:0 FAT CLAr1:; LATER' AL UD Or,X•MAIN �l ! 6.I4"irtAT s10' W(1GL 111 FIF'L f,/ /1 .o FIRIIiC,,`,li•EE' rut, .- eLh.H (1 0 L.) (ULLD 04.LF :-k.=...•,J i� COJP.To 3„.It•' c A' °TOCK;, TOLCO FIC,, 4A PIPE, CLL.r11 (of. L0'JhL1 LATE AL4' LOf1GITUOIHAL E.Q. ��ACF l 1 1z-Illz t t 4" P 4 61 L.c3 3c AL_�RN1 Va "4/TW i >f Piat •A, PO -.VA 4" 4Roove CIO vf/4" cAla.aove FL evi 4" F3uTTEP_.Ft V vA 101.7 T"AM t&. Tit ?E12 5 .1 ITC.tta ,S 0-11 1 r'- FIPESTP.►.143 - 1r Q. pa e55 • ETA •e-- 4''6e.oave 2-3 1-4 I SEI'. iD l 11 'A' 1/Zt-c." }C ltERLJLIN.l l_ J 1. WET SYSTEM IS HYDRAULICALLY CALCULATED TO DELIVER .15 GPM PER 5(1 FT. OVER THE HYDRAULIC MOST REMOTE 2500 50. FT, ANC) .19 GPM PER SGL FT OVER THE HYDRAULIC MOST REMOTE ,1500 SQ. FT- / 6s 2. PENDENT SPRINKLERS ARE 1/2" ORIFICE,PENDENT, �tITH RECESSED CHROME ESCUTCH., IN THE SAI F 155 - AREA. BRASS UPRIGHTS, IN OPEN AREAS, AND /`1°I3RASS UPRIGHTS IN COMBUSTIBLE BLIND SPACE. SPRINKLERS IN THE STORAGE/RECEIVING AREA TO BE 17/32' ORIFICE 286 DEGREE UPRIGHT SPRINKLERS 3. SPRINKLERS TO BE SPACED AT 130 50. FT. MAX. IN ALL AREAS WITH THE EXCEPTION OF THE STORAGE RECEIVING AREAS WHICH WILL BE SPACED AT A MAXIMUM OF 100 SQ. FT. PER SPRINKLER HEAD. 4. WET SYSTEM MAINS AND WELDED LINES ARE SCHEDULE. 10 OR SUPERFLO STEEL PIPE WITH FLEX CONNECTIONS. DRY SYSTEM MAINS ARE GALV. THINWALL WITH FLEX CONNECTIONS. DRY LINES ARE 5CH. 40 GALV. PIPE WITH CAST IRON FITTINGS. 5. 'THREADED LINES ARE SCHEDULE 40 PIPE WITH CAST IRON FITTINGS. 6. RISER NIPPLES ARE SCHEDULE 10 OR SUPFR11.0 STEEL PIPE WITH FLEX CONNECTIONS. 7. ALL EARTHQUAKE. BRACING TO BE PER N.F.P.A. ,»` 13. b. THE DRY SYSTEM HA5 BEEN DESIGNED IN ACCORDANCE WITH THE' REQUIREMENTS OF N.F.P.A. 1 13 FOR AN ORDINARY HAZARD PIPE SCEDULE SYSTEM. 9. ALL DRY SYSTEM MAINS SHALL %OPE A MINIMUM or 1/4" PER 10 FEET AND ALL LINES SHALL SLOPE A MINIMUM OF 1/2" IN 10 FEET PER N.F.P.A. 113. 10. MAIN PIPING SHALL BE FLUNG FROM TIIE TJI JOISTS WITH TOLCO FIG 130 BEAM CLAMPS, 3/8" A.T.R. & RING PER N.F.P.A. /13. 11. LINE PIPING SIIALL BE HUNG FROM THE TJI JOISTS WITH CEILING FLANGE. 3/8" A.T.R. 3/8" X 1 1/2" LAG BOLTS & RING PER N.F.P.A. /13. FIELD NOTES UPON COMPLETION OF INSTALLATION THE FITTER MUST CONDUCT A 2" MAIN DRAIN TEST, A HYDROSTATIC TEST OF ALL. PIPING, A TRIP TEST OF THE DRY SYSTEM. AND AN ALARM TEST. 4"9.5- 4' 4' FLaa1 I e55 • pre\ 1111.11101.11 SST / 200 roAi... R1$e,2 Noutirr• At r3- ceoi F trfrefC, 4'ALA8M VA e4S P�a�VE r� Ir1EiM V vI. "1° 4112.5 : 7 I.2�, Q DENOTES AN UPRIGHT SPRINKLER HEAD. e DENOTES AN UPRIGHT SPRINKLER HEAD ON A 1" SPRIG DENOTES AN UPRIGHT SPRINKLER HEAD ON A 1" SPKIC PENDENT SPRINKLER ON A 1" DROP. • DENOTES A PENDENT SPRINKLER HEAD ON A 1" DROP. 0. DENOTES A DRY HOKIZ. SIDEWALL SPRINKLER HEAD. 9 DENOTES A FLEX. COUPLING. DENOTES A ZERO FLEX. COUPLING. DENOTES A FLEX. CAP AND COUPLING. / DENOTES A HANGER. DENOTES A TWO-WAY EARTHQUAKE BRACE. • DENOTES A FOUR-WAY EARTHQUAKE BRACE. 0 DENOTES A HYDRAULIC REFERENCE POINT. eE DENOTES CENTERLINE OF PIPE BELOW DECK. PI Pe 5v64,0 .,w s4. 4+ 13t, #may vA TAMPEi! 11'5 1 CauPLIN4 C � }11.2-7 z-- I S• Ctrl Ceri 9"leaLO►3E MoD U-3 t:)R.y PIPE vAs. vJ/ TRi M t Pe%s, %r tr04 C31JZ11 �Za 1111 ,w/ra�r 1111. Deor 4 -114 -Hee. le- VA, FSAG4L 4" €10 4 14 E.D.G.� C lYS I O er-Z- i R S ER DETAIL"B" t ANDA ACCEPTED° THOUT COMMENTS. AS NOTED IN RED PER THE ATTACHED LETTER The drawings affixed hereto have been reviewed and accepted by the City of Tukwila Fire Dept. Additions, deletions or revisions to these drawings after this date will vola this acceptance and will require a resubmittal of revised drawings. Final acceptance is subject to field - inspection by a representative of this department DATE: .1.c BY:. /2 ._.........�.,. CITY OF TUKWILA 575.4407 DrrAiL Inc 4 Yz "-= / =0a TUKWILA FIRE DEPARTMENT Please call: 575-4407 and give this job No. and exact address for shut. down or restoration approval, FACTORY MUTUAL, ENGINEERING ASSOCIATION CHICAGO DISTRICT OFFICE Pt,IM11S ACCEPTED SUBJECT TO CHANGES INDICATED AND COMMENTS IN TRANSMITTAL LETTER I1w' appy equipment should be used and the inetaliatfon should conform to FM recommended good practices. Final ecce radon and will only be given waen acceptance of this job is subject to field national Automatic Sprinkler and Fire materials and tests have been certifedus ng separate form should be submitted a Control Association form 85 or equivalent. A fluorescent lights or other each riser. This acceptance is void if there biiity of the FM co obstructions not clearly shown on these prints, iia• Reviewed by . ,y Is limited to their Insurance policy coverages. Dere _•„--c�..,.,.�_r� . RECEIVED JUL 2 2 1994 NORTH COAST ENTERPRISES HYDRAULIC INFORMATION STATIC P.S.I. RESIDUA1L P.S.I. FLOWING G.P.M. THIS SYSTEM DESIGNED TO DELIVER G.P.M. OVER THE HYDRAULIC REMOTE SQ. FT. WHEN SUPPLIED WITH WATER AT THE BASE OF RISER AT A RATE OF G.P.M. AT II P.S.I. OUTSIDE HOSE INSIDE HOSE II� RACK SPRK. GENERAL NOTES 1) INSTALLATION TO CONFORM TO N F.P.A. # AND 2) ALL MATERIALS NEW AND APPROVED. 3) ALL WELDING PERFORMED IN SHOP AND IN ACCORD- ANCE WITH A.W.S. D-10.9. 4) PAINTING OF PIPE NOT IN CONTRACT. 5) ELECTRICAL WIRING NOT IN CONTRACT. 6) EARTHQUAKE BRACING PER CODE. 7) USE FIG. # 401 POLISHED ALUM. CANOPY, U.N.O. #1 #2 #3 #4 #5 #6 #7 #8 #9 HANGER LEGEND - EXP. SHELL, ROD & RING - C -CLAMP, ROD & RING - POWDER STUD, ROD & RING - ANGLE CLIP, ROD & RING - L -ROD & RING - EYEROD & RING - COACH SCREW, ROD & RING - CEIL. FLG., ROD & RING - U HOOK SPRINKLER HEAD SYMBOLS 0 UPRIGHT ON LINE ©. UPRIGHT ON 1" SPRIG UP .,PENDENT ON LINE 0 PENDENT ON 1'4(Of3OP UPRIGHT & PENDENT DROP • UPRIGHT SPRIG & PENDENT DROP q • SIDEWALL DRY SIDEWALL DRY PENDENT DROP ALARM: SPRINKLERS ORIF TYPE DEGREE TOTAL SPRINKLERS FINISH QTY REVISIONS CONTRACT WITH: NORTH WA, STATE CONT. LIC. NO. TR - IA NF-P2740P SA12,51-10M1,1F� 420 5'('12AMQEIZ COOL-GVAP ' tUKWILA1 I,JASUI NCg1'fN SCALE A5 5 14011 N BY: P, CARNAI-lA14 TRIANGLE FIRE PROTECTION P.O. BOX 264 WOODINVILLE, WA 98072 527-5211 "' 483-5211 DATE: 1-2-1-91 JOB#: g4-1'1 I OF CD HE COMPLETE LINE/167000 ao- d i 11 FIRST FLOOR LEII.IKG PLAN fY' 0 N N crt FACTORY MUTUAL ENGINEERING ASSOCIATION CHICAGO DISTRICT OFFICE PLANS ACCEPTED SUBJECT TO CHANGES INDICATED AND COMMENTS IN TRANSMITTAL LETTER 1rM approved equipment should be used and the installation should conform to FM recommended good practices. Final acceptance of this Job is subject to field exams. n and will only be given when materials and tests have been certified using' Notional Automatic Sprinkler and Fire Control Association form 85 or equivalent., A, Mpotate form should be submitted for each riser. this acceptance is void. If there are fluorescent lights or other obstruction not clearly shown on these prints. Lk - batty of thenEM ides limited to their insurance policy coverages. atitimed by }�/ 75/4 �/� nog L RECEIVE JUL 2 2 1994 NORTH COAST ENTERPRISES HYDRAULIC INFORMATION S P.S.I. RESIDUA r P.S.I. FLOWIN •.' M. THIS SYSTEM DESIG 0 DELIV G.P,M. OVER THE HYDRAUL •'" - ► OTE SQ. FT. WHEN SUPP ATA RATE OF ITH WATE G.P.M. AT 0 • . E HOSE INSIbE HOSE THE BASE OF RISER P.S.I. RACK SPR GENERAL NOTES STALLATION TO CONFORM TO N.F.P.A. # AND 2) ALL MATE • NEW AND APPROVED. 3) ALL WELDING P ' • RMED I . ' OP AND IN ACCORD- ANCE WITH A.W.S. D-11 4) PAINTING OF PIP ' •T IN C• ' 'ACT. 5 ELECTRIC ' ,1IRING NOT IN CONT T. 6j EAR AKE BRACING PER CODE. E FIG. # 40? POLISHED ALUM. CANOPY, U.N HANGER LEGEND #1 - EXP. SHELL ROD & RING #2 - C -CLAMP, ROD & RING #3 - POWDER STUD, ROD & RING #4 - ANGLE CLIP, ROD & RING #5 - L -ROD & RING #6 - EYEROD & RING #7 - COACH SCREW, ROD & RING - CEIL. FLG., ROD & RING #9 - U HOOK SPRINKLER HEAD SYMBOLS 0 • UPRIGHT ON LINE Q • UPRIGHT ON 1" SPRIG UP ® , PENDENT ON LINE O - PENDENT ON 1 DROP r UPRIGHT & PENDENT DROP UPRIGHT SPRIG & PENDENT DROP a - SIDEWALL 'w DRY SIDEWALL DRY PENDENT DROP ALARM: SPRINKLERS ORIF. TYPE DEGREE FINISH 0 -TY REVISIONS NORTH o TOTAL SPRINKLERS CONTRACT WITH: glo WA. STATE CONT. UC. NO.' TR - IA . NF * P2740P S�AP�S U01'I�LIF�. ‘loa sTRANpry. g. t3o,ut.-e.vm242 'fUK.I41L.A ,TRIANGLE • FIRE` PROTECTION SCALE: ' I BY: R. "GARNAEIAh1 ' BOX 264 " WOOOINVILLE, WA 98072 527-5211 , , d 483-5211,', BATE. -. , t , 94 TOB #. :,i 141' HE COMPLETE LINE/167900 1 0 cr 0 z CC .J 0 RESIDUAL P.S tn to 0 0 Z l- O to • w J w O 0 w C7 w 2 1w > F— 0 2 w CC > U_ J 0 w H w 0 a O w 0 w t1 m w w 1- 0 w -J a co w IL O ATA RATE OF SO RACK SPRK -�- INSIDE HOSE OUTSIDE HOSE_450 NFORMATION RESIDUAL P.S.I d• (n L Q GI co u FLOWING G.P.M. THIS SYSTEM DESIGNED TO DELIVER G.P.M. OVER THE HYDRAULIC REMOTE SQ. FT. WHEN SUPPLIED WITH WATER AT THE BASE OF RISER ATARATEOF OUTSIDE HOSE 450 INSIDE HOSE J. 2o— c� 20—v 20 --O ao—o 2.0-0 20 0 0 y.,.1,�..��irwr. ...••••••,, 10-04 RxrtatC 1600 .FT, 0 10' 3 O 4 d I 4201 N 1y 30 z oz 51- 0" 3r 1 4,4 Int 1,4 4)31 -6C-, k 4.4 ate, 3 924111 244E -44 le 263 20?• 0 kt N 4-4 s vsa _•i, b \? o 9.. °1111 ?. 14. N IVA 11-0 44 / 0 0 1 .r a (14 8-0 T ..11....40...:. 1 F21-0 4-4 g-0 ",p IZ-4' 1-4 �a� 4-0 1f- 44. Ido N N LOS -o +11 5 - d' .i5 40-0 ' 5-0 !� 1111 a1 K 5' -OI 10 - 0 0-4 10 /' P.DJAC-5,NT •re_HARTHYDRAULIC INFORMATION .15/0_5-00 STATIC P.S.I. iSS" RESIDUAL P.S.I. 141' FLOWING G.P.M. aiq THIS SYSTEM DESIGNED TO DELIVER 1 5' G.P.M. OVER THE HYDRAULIC REMOTE sco SQ. FT. WHEN 'SUPPLIED WITH WATER AT THE BASE OF RISER OUTSIDE HOSE 450 INSIDE HOSE RACK SPRK STATIC P S I 1S4 RESIDUAL P.S.I. 141 FLOWING G.P.M 2710 THIS SYSTEM DESIGNED TO DELIVER . 31 G.P.M. OVER THE HYDRAULIC REMOTE 1420b SQ. FT. WHEN SUPPLIED WITH WATER AT THE BASE OF RISER OUTSIDE HOSE ISO INSIDE HOSE s 0 RACK SPRK 413.- 2.01 • 0 N 44 420 4 3" - 4aI 4 21-061 -+fit / 10-0 1,—$ CO ".0) N i Jo Slb 112.4.24 -au, (2. c.FiV1•-.141 06o0 Sc T. -QC��v /(132 X Zediov �y a1 / x 6-E ( -80 4r 3-4, 8 0 04, A t -t m r42-1 I -s• 41-15 V 45) ' _1 1‘41%21-8 616 o --►d-1---- ----t o @—� -- O 1 � ,• 1 N N 1+x2.1 -061, 3 •-ems •m-tort---um-- 0 Ix 21 * 614 0 z--8 5-4 4-6 f` 1141 1-0 21-0 20-0 T 20-o 10--0 1 xis 2i-0 C-,(, 1kx13 1111/.-0�,,�, .- _ -:Y _ / 1 fit,� Not ct>3 to ,. 4-61 -6 4.0 S -Z 1.4 3-4 lilt 61111-0 lir b 164 r Z1.64,15J ickcv-4 erE 150 o Sm.FT 4. N 3 tet Yo -St n tit 4,4-6 5 -4 14KZ/-0616, Y' 1%4x13.04..1) 5S 1�0 ' ,f4 . /3.4 444 '1117 / -8 ho 6-0 8-4 10 ‘14„2.4-o 44 /•— .4,11 21-06,6, 'ED1141(11'0414 11a1t2.1-0611) 0-O-----/--0 0 _.--- II 1, F. V 9 N .1.4x21•44444 =-n- 1-4 3-4 G -b -Ia 2-8, O 11 0 114,21-0 4610-4 6 4-0 s-4 / 4x21 -06G O 41 O lax x3.044 �:--/ /.) -F.) / . /06..I-� 14x /3-0 61) / 0414 4 3w21 -U .:rich .../ 0 }G •% _ rr 21'(h.i167 41. t } " � 9 /! 21-O GET H 14913-0 c74. ro 14x11-0 c,4 ,t._ -1111_..-C}...,1 ,..... (")4(")4 �, 8.0 2-0 1-4 11-21-4ef-4 -Pi-, / .-• 1 -6 -lo I 11-04,/ 'II,0 / te..7 4-11 45- lal.x►-o 6,� fit -3 V 112,E ZI-0 461 4-, 1/4x 21-0 At; Nf ¢-4 �---;-o---CST 11x 15-Z, 4 0 1 -1a 011 443 U 11ixZ1-4444 / ----0 er--14-- 1 EMOTE 100 s G►. +< T 8-0 . 2-5 3- 4� 3 11� 2I-0 6, E•, I 163 11pr21-D Ni C.44 _..,.e,tc _{7 a 7-1. �1 ' 2-0 0 diVit /c of 113 C oit 0403 /3416. €1) 4 1 1 1-21-4 t0 2 • 112. 5-0 614 tri • 71. cAHopy PL -AN 157- e•-;12.1 HYDRAULIC INFORMATION .0/ isc5r„, STATIC P.S.I. / 5 5 RESID*P.S.I. /41 FLOWING G.P.M. 27,76 ime 1..000 5-6 10 1 T /-RggHYDRAULIC INFORMATION .1 (4" } gee) ST TIC P.S.I. 155 RESIDUAL P.S.I. 141 THIS SYSTEM DESIGNED TO DELIVER . G.P.M. OVER THE HYDRAULIC REMOTE )500 SO. FT. WHEN SUPPLIED WITH WATER AT THE BASE OF RISER ,OUTSIDE HOSE 11S0 INSIDE HOSE RACK SPRK 451 -- .111.1011001010.111001.11....111 —0 12E14 0 -TE" '2500 0 STATIC RSA. 165 RESIDUAL PSI THIS SYSTEM DESIGNED TO DELIVER /5 G.P.M. OVER THE HYDRAULIC REMOTE a Goo SQ. FT. WHEN SUPPLIED WITH WATER AT THE BASE OF RISER oUTSIDE HOSE 450 INSIDE HOSE SO RACK SPRK. GENERAL NOTES HANGER LEGEND SPRINKLER HEAD SYMBOLS ALARM: QO N �1 w 114r21-064 0 1$„ Zl-061/ Ips X11 i4 !/ / O+ • /0 I! zl-4464 �'/,,• •• ii4A ZI— 4 0- x 21-OGcy , I1{�, 21-0 v / ---.-} /0 , `0 0 2,s4•4 4 >, 1► 0105 r � C et. I Op 4 -Ib 14x21- 614 I /4 X2o 614 �2-e 5-W 3-4 G-3 4-0 1-!0 2T4 G-13 3-4 z"4 34 1 N 0 \0 ro co 44 104 61 4w} ie4-4- .1106 161/-466 3-4 2 0-4-71--ifrItt_43:14.:4f1:1443.74.6 " 31)74 43:4:1: Ij3 3y 21-064 44 0e1 44. o PIRST 011F-RNAO PIPI)\4 121,-- A 1/ ve.:;;:0 01/ S\ REVISIONS THIS SYSTEM DESIGNED TO DELIVER )9 G.P.M. OVER THE HYDRAULIC REMOTE / 5 0 0 SQ. FT. WHEN SUPPLIED WITH WATER AT, THE BASE OF RISER OUTSIDE HOSE 456 INSIDE HOSE RACK SF;RK. 1) INSTALLATION TO CONFORM TO N.F.P.A. # 13 a-41 2) ALL MATERIALS NEW AND rt#1 APPROVED. 3) ALL WELDING PERFORMED IN SHOP AND IN ACCORD- ANCE WITH A.W.S. D-10.9. 4) PAINTING OF PIPE NOT IN CONTRACT. 5) ELECTRICAL WIRING NOT IN CONTRACT. 6) EARTHQUAKE BRACING PER CODE. 7) USE FIG. # 401 POLISHED ALUM. CANOPY, U.N.O. - EXP. SHELL, ROD & RING - C -CLAMP, ROD & RING - POWDER STUD, ROD & RING - ANGLE CLIP, ROD & RING - L -ROD & RING - EYEROD & RING - COACH SCREW, ROD & RING - CEIL. FLG., ROD & RING - UPRIGHT ON LINE - PENDENT ON LINE - PENDENT ON 1" DROP - UPRIGHT & PENDENT DROP - UPRIGHT SPRIG & PENDENT DROP - SIDEWALL 4> - DRY PENDENT DROP SPRINKLERS TYPE DEGREE FINISH QTY aia C-1-1 ROM 4 C.14 ROM M PRY P01-0, Ram fet .65 0 4.9 FACTORY MUTUAL ENGINEERING ASSOCIATION CHICAGO DISTRICT OFFICE no eineue* egiti0ment should be used and the installation should conform to Al Ottemmeeded good practices. Final acceptance of this Joh Is subiect to Nig ening- eietteA And wig orgy be given when materials and tests have been certified usina Nittlortel Automatic Sprinkler and fire Control Association form 85 or equivalent. A operate form should be submitted for each riser. This acceptance jp vpid if then bill" of the FAI No fluorescent lights or other obstructions not 'clearly Ahown on Mese Mnts. Lliv- is tad to their insurance licy cover el. IteVreVied by 4.1.440%11k 141-4_4(..eobate NORTH SrAN5 RECEIVED JUL 2 2 1934 NORTH COAST ENTERPRISES _41 TRIANGLE FIRE PROTECTION P.O. BOX 264 WOODINVILLE, WA 98072 527-5211 483-5211 TOTAL SPRINKLERS CONTRACT WITH: WA. STATE CONT. LIC. NO. SCALE: V8=1-0 DATE: 2.1 94 4 `TI IF CC7MPL ETF L INF 1157900 0 ql 0 ry 0 0 20 = o" ZO - 0" I1) ZD'• o'' ZOO" • 20'- 0" s. ■ • • • • • • 81_ • • • • • • 1 1 • • /2'-D„ • • • 1 -1 • • • • • lz• 1 a a • 4010 1 • X • • • • • • 1 1 • • 1 1 • • • • • • • • • a • • CZ) • • • • • • • • • - a I` • • • • ■ /0'-0" • a ■ • • 12'-D" • • • • a • • • • 411 /2 '-0" • • • • • - • • a O - .41 • - • • • • • • • • • • Sr ONS 0 2,4o ' t-ooP zip HYDRAULIC INFORMATI ON . /9//3•00 STATIC P.S.I. / 55 RESIDUtWL P.S.I. /4/ FLOWING G.P.M. 2.790 it THIS SYSTEM DESIGNED TO DELIVER • /9 G.P.M. OVER THE HYDRAULIC REMOTE /5o SO. FT. WHEN SUPPLIED WITH WATER AT THE BASE OF RISER ATA RATE OF 330.03 G.P.M. AT j4 7/ 5 P P S I OUTSIDE HOSE45O INSIDE HOSE 5o �1 RACK SPRK. -&. I,I PI FLOWING G.P.M. 27 Now THIS SYSTEM DESIGNED TO DELIVER ( G.P.M. OVER THE HYDRAULIC REMOTE SQ. FT. WHEN SUPPLIED WITH WATER AT THE BASE OF RISER OUTSIDE HOSE 450 INSIDE HOSE 6e) RACK SPRK. CL -N( pL-AN £CAA—i : I/g : !V— O 4,1 • a N e 0 • zc' 0" 20'-0" PIN/AU-A/C F•R- EU.VATh -MMMmM O mono 2o'- o" 20'- 0" it• bp _ 2.."..:.........-,._. w.11 0 �. 6- `U own 2i 5 0 41' 1 • nrw,IN.,r 1..1.11,....I� 4A _o� z18 I M I sd-1L7' r°t '+17x1 I I ( .r UM err AMNWr ato MUM (o u I3 I 111111•111 00111414••• .11....11,0, 1/I11111I141 {II r 77, nWwl' Wr IY�W il' Nr� I�Ir� ,II r 777 ._ 1F--•RE*+orrE 1500 56.r"r. _if--:--12Er10TE 2500 5/Z.FT. IwNNMu. nor 11• n1„ MIM^'WIwW'r'1•i111, 4111MYMWM1WNmo „...Mp IxNXr1,,„„6II „...,6v�� ,rRMwWwwMMAl b,6 ",,,, WM"IM'IIMN6MIwNll�,tr, 11 rlr t'•11 { M 'rnnN1MM""4111. gED t -1.6-1N HAIN Rai Isis LLVELQ 28'-5" ( f2' -III' a„F.f) lo IwmMMMM111'n 0 4.a BB= 2.11 Co" tr -'1 111111114 DROPS TO Br 6,1-104. 110/ Loe44 Acsr;•,(.Lp 4.4,11 »AwWwlwwMvr' I NrwO^rl lt9 "J!!w'110 'Ic,9" '."�tr;.,LiPrl ' 1b1"Id r1 IM 1ryompIM ;.n AX 111111161160,1.0101.11 iM +uV.irWrh�T MWwNNr'puwur11.41 " 'Imn II II��IJ�rI IUWwru un 1.0144,11, •* ), Iw WM PWIMNM Wrn nW O glie1'' I 1{.I-} I Bs 4r-7"1 *61AI-04 wl 0- • ..�.;�.ru� Y 1u�... ,uv.. " Ip N1wl yq X I r"�'"I. ,IMI 'wlwe lwwlrm 4.444444004444nrwnwgww*r*lwNrr4404wWnwne«400)941,41�"' oo II 11,,MNu11,11, .IXr n11nWN�'Rlwnl l 111°" 11+1 I'M' Nt�r,1 N 5x2.4 At h a I N Izu rl 5 L�JG:►_- 2q-117.."‘ 13N-7 Z " A. VS') Q 'YJ 1111 1.11,1 O I I*6k Is '0 0 41 7xI-4 N 1. r x up to ��...-� L /N£S HAM, .//s4-..)4) RAD 4 RI N 4 W TYP Die 4S,oMS � F go ww 0111MNA' MN40, o,IMA1WIwIM1'11001rWN^ • IMMIX w � 2 6-5 ,.6. • Ii: ii l'' q'�I' ""'i-rr��n� nii,i:.rM.NrI�MIIIn1NM11'11� "uVMMNMI'MMNWIIiWwwMMMY11wM11Ywi, M 0 N I i I •- 1 '�'�"" w rnlNwwM'IMIwTIq����r v o yl„� lull ww- MrMMIInIY,MwM MN I i l 1 II �f �D M 111' Ipo , 10 11+1. IWM 4YI'wI � I1 ' MT •1 !,. �• �WNw�' uWr '� I ew'A�r"MIAN. • 1 +II c 2.1-0 MI 9, 11 v 21-0 cP 0-10 tn 01, *7x4-4 0 1111. 14,21-0 6G mo,o66,64,6111.' .1,1,111,14161.1 5-7 ---"--71.-----' '7f - 0-10 LINE 2. D 6(z--1/,vE-54 1_,...,__________"" : il. N LE2 V- E.1.3-: 4-5 ; !..7): • F. (F.0) Nit z- • 5-7 to 2-7 14 D-0 64 0,6f 714 • -44 i3 tn • • 1.1 0 • 26 At szt. 0.1 2INCI‘ FACTORY MUTUAL ENGINEERING ASSOCIATION CHICAGO DISTRICT OFFICE itimivomPLANIACCEPTED SUBJECT TO CHANGES INDICATED AND COMMENTS borer, Ihmonscento the Fmlirts or other obstructions not ClearlY shown 011 these Prints. Ile - FM approved equipment should be used and the Installation should conform to separate form should be submitted for each riser. Ns acCePtance is void Mere Nation& Automatic Sprinkler and Fire Control AmcIation form 85 or equivalent. A nation and tvid only be elven when materials and tests have been certified usini recommended Rood practices. Final acceptance of this lob is subject to field exam1- imited to their insurance PolicY COWS IN TRANSMITTAL LETTER "or :116,TI,1-, 4 11(4 01 nett RECEIVED JUL 2 2 1994 NORTH COAST ENTER PRIsES GENERAL NOTES 2) ALL MATERIALS NEW AND VI- Ft -1 APPROVED. 3) ALL WELDING PERFORMED IN SHOP AND IN ACCORD- ANCE WITH A.W.S. D-10.9. 4) PAINTING OF PIPE NOT IN CONTRACT. 5) ELECTRICAL WIRING NOT IN CONTRACT. 6) EARTHQUAKE BRACING PER CODE. 7) USE FIG. # 401 POLISHED ALUM. CANOPY, U.N.O. HANGER LEGEND - EXP. SHELL, ROD & RING - C -CLAMP, ROD & RING - POWDER STUD, ROD & RING - ANGLE CLIP, ROD & RING - EYEROD & RING - COACH SCREW, ROD & RING - CEIL. FLG., ROD & RING SPRINKLER HEAD SYMBOLS 0 UPRIGHT ON LINE 0 - UPRIGHT ON 1" SPRIG UP - PENDENT ON LINE - PENDENT ON 1" DROP - UPRIGHT & PENDENT DROP • UPRIGHT SPRIG & PENDENT DROP 41/1 - DRY SIDEWALL * - DRY PENDENT DROP ALARM: SPRINKLERS ORIF. TYPE DEGREE 212 al a TOTAL SPRINKLERS FINISH QTY /5(D 135 REVISIONS ( CONTRACT WITH: NORTH 1-1114.1411– A, le-IASI-I INCTION TRIANGLE FIRE PROTECTION WA. STATE CONT. LIC. NO. TR - IA - NF - P2740P P.O. BOX 264 WOODINVILLE, WA 98072 527-5211 483-5211 BY: P. CARNAHAN ftrzc 420 STRANDER BLVD ASSOCIATED PERMITS 94-F-233 24 X 38 PRINTED ON NO. 100011 CLEARPRINT • l\ RA \ A, V 4u) ahreiod-eir Elvd ❑ WITHOUT COMMENTS. 'SAS NOTED IN RED, ID PER THE ATTACHED LETTER The drawings affixed hereto have been reviewed and accepted by the City of Tukwila Fire Dept. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings. Final acceptance is subject to field - inspection by a representative of this department DATE: 1D, -!Z -9y gY:.)/.1414-rip CITY OF TUKWILA 575.4407 OCT f-;.4 4,1954 TUKWILA FIRE DEPARTMENT, PI A se call: 575-4407 and Olo this job No. ?`/- F —2.33 and eltaQt address for shut- CbOttl Qr koataration approval. uL 0 sK�-1. .1446(7 l�,h J� (&F_/ 40-34 qcS £,eeti StS SECURITY SYSTEMS; INC: 6ID-f 127,<I ST. E . TAC=OMA, WA c784-45- SCALE: 84--S SCALE: DATE : q-21- 94 - APPROVED BY: DRAWN BY S,_..J REVISED SEARS ")-1ONIELIFF" FIRS ALAFv SYSTEIM DRAWING NUMBER a -P - ( 24 X SO PRINTED ON NO. 1000.1 CLEAAPRINT • j 1 ( LJ 11 , El 0 MAIN FLOOR PLAKI -C. LJ -1 ri.,. El 51C, rC-/ } r Y NA 171 (.1'3 - D FIRL/BIJRGLAR ALARM PANEL MAN Lif.; L POL. /TONST flci 1-10R/Q/STROEE. 0 FLOW SWITCH 0 -TAM PE R 2 WITCH /ND) CAT 5 ME AJIJMEEP 0F CDNI DUCT 0 O. SMOKE DTEYcDR RR EL VA TOR R E L HEAT DETECTOR I:7OP ELEVATOR L ALL ) ELLBST.P,o5E -WEATFIERPROor F ALL C_DJDUIr TO EL 3/4' MINIMUM 2. MANUAIL PULLTATIOMS TO SE MOuNTED AT 54" To TOP or DEVICE. ABOVE T)4E. FINISHE.,D L,C)OR LA.F.F.) 3. HORN/STROBE...--To 8E. mout\r-rED AT LOWER OF 80" A,F,F. OF (211 BELOW ThE CEILING. SEE S4EET 3 FOR ELEVATOR RE:CALL DETA)L SS SECURITY SYST1MAS, S -T. E. • TACOMA, WA 9849 -5 - SCALE: 3/32".11-01' DATE : APPROVED BY: DRAWN BY REVISED SEARS "HOMELIFE" FIRE AL:AANA SYSTEM DRAWING NUMBER 2. 0-P 3 - • : ' MUrk7...1111TSUIMMIENIMIIIMIUMITUCMISEMMENFEWPAIMVUTWALUMUTOTIROWKWSECUMErUttlMMUTFt, Vkkkie2110Unk1644022Allif49.:krMIV:IN?iUttkIMIUM,Alt,..7,7r' L. E I 111 uNT 7,21 P ELE V/-17 O .:.M/ 1 2,0P FL001 liL7" k I'J, TE FLOOR OL J FLO() MA 1 r.1 1= LG2' zOL on1E r1 Fl n p p D U CI 11 Cl n rol 0 IFSJC j•c Gr. 4, F�- 1 SF_COND <D R P[y._ Ai 3/32",P-0 24 X 36 PRINTED ON NO. 1000H CLEARPRINT • QTY. 3 21 BATTER" CSAL._2,Li %'i 1 10KJ DE SCR IPTI ON MODEL if ALARM PAME. L 178112GB SMOKE. L)E, i QR PORN STRO. lO"BELL /4-S! 533 6L-1..)-)9 • )2 A413 -G/0 -/-R STANDBY (A) .1SJ . oC.Ao�z N/,�1 STAAJP6 V BATTERY CUR R EMT Tt.2JL ST9N1D8' AMP -POOP, TOTA'rL C, 1-100FtS) ALARM CO1`1 j:J)T !OiJJ 1 ALARM PAMEL D8/)2 G 3 3 SMO) -KE DE-TECTOR )4.5 - NOR WCTRLDEDE SNORM/CTJ)8,E. 73.3b!-0-)4-) z)C. /O' BELL ME>-G)o 12- ALARM 2- ,hL/RM CORREIJT TOT/ -)L 14) N111J0rcS ALARM L.x TOTAL AMP-)p,S REdUJRED TOTAL AMP-ROLiR L PROV)DED 20NE I CM M>>J FLOOR') L -® ZONE FOL Q �oJ.��: 3 UL EZO NE 4 /J.2OV/ c D8J12B ALARM CH) (ALTERNATE_ F!_OJR) ZONE 5 EOL 100 ,060 TO T/a L '5C) .0003C., 4, SD,:'. A fJ 7, n AE .2 EGA S, /=1 . 94/),4 i SIG, 1RC.U)T ) OL SIG, CIRCUIT EUL —40-70 D1?_ ;?. KEYPAD A N N UNC )ATO R R)SER D1AGRA1V1 70 50/1 R D /0, -TTS, S4 S S CL)RITY SYSTF 6)0- 112 T" c,`i". E . �TACOf \.,M.A , w/\ INC-. 9844 SCALE: _Z/7:?,,./- 1 C,„ DATE : 9-2)-(74. APPROVED BY: DRAWN BY REVISED '' F L /` FIRE ALARM SYSTE M DRAWING NUMBER