HomeMy WebLinkAboutPP - 561 STRANDER BLVD - UNKNOWN - PERMITS AND PLANS561 STRANDER BLVD
ASSOCIATED PERMITS
12-S-074
SITE LOCATION
CITY OF TUKWILA
FIRE DEPARTMENT
444 Andover Park East
Tukwila, WA 98188
206-575-4407
Date application
accepted:
FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
King Co. Assessor's Tax No.:
Site Address: 5,1 S-rDr 8► vd Suite Number: Floor:
Tenant Name: C( \c\C, \j(\�)1Q� \Qn W UC New Tenant? ❑ - Yes No
Property Owner's Name:
Mailing Address:
CONTACT PERSON -if there are questions about the submittal.
Name: S cry. Int ilSOn Day Telephone: /if 45'/'7/1)&7
J
Company Name: gCvO»3fl V VR! . �o�' i -i dfl /
`V
Mailing Address: D Q?( `2.\\? k\\ `iex_ l t $2
E-mail Address: y_ \ 3 1 CVO ) . Com iTy Fax Number: 142.6W� tRlp �
City State Zip
Valuation of Project (contractor's bid price): $ 1 . dO
Scope of Work (please provide detailed information): C S -vie_ syfintaer r -e
ak
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature: CCil We31/,2z VL Date: /Id/)2_
Print Name: "ea ?l Y)7&)j^1
Plan Permit App.doc
Day Telephone: 4z6.4/ 7104,9'
5/14/10 TFD FP Form 8
•
FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS
Project Name: Pacific Insulation Products
561 Strander BI
Permit No.: 12-S-074
Date: April 13, 2012
Reviewer: Al Metzler
Fire Protection Project Coordinator
(206) 575-4407 option # 2 (Inspection Requests)
(206) 971-8718 (Plan Review Questions)
• Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross
mains, and branch lines 2.5" and larger. Bracing is provided for the last length of
pipe but within 6' of the end of a feed or cross main. Bracing is required unless
all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for
any size pipe, 9.3.5.3.
• Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4
exceptions, 9.3.4.
• Longitudinal sway bracing is a maximum of 80' for mains and cross mains and
within 40 ' of the end of the line, 9.3.5.4.
• Provide lateral and longitudinal bracing for changes in pipe direction per section
9.3.5.11.2 for pipe size 2 1/2 inches and larger.
• Restrain branch lines at the end sprinkler of each line, restrain against vertical
and lateral movement, 9.3.6.3.
• Restraints for branch lines shall be at intervals per table 9.3.6.4 and section
9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6.
• Comply with ASCE 7-05, section 13.5.6.2.2.
• Provide sprinkler protection beneath all obstructions greater than 4 ft. in width.
• Extend sprinkler protection to all combustible concealed spaces.
• Comply with NFPA 13 obstruction tables.
• Comply with obstructed/non-obstructed construction rules for sprinkler head
placement.
• Sprinkler heads spaced closer than 6 ft. apart must be baffled.
• Modifications involving 20 or more heads require hydrostatic test and system
isolation if necessary.
• For dry pipe and double interlock preaction systems, in addition to the standard
hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24
hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the
24 hours shall be corrected.
• These conditions apply to all sprinkler piping exposed as necessary to
accomplish the permitted scope of work.
All code references are NFPA 13, 2010 Edition.
Clip Hangers
a Hanger Rings: UL Listed & FM Approved
I Hanger Rods / Fasteners: Comply with NFPA 13
0 All Thread Rods
I Finishes:
0 Machine Thread Rods
0 Standard Components o All Galvanized Cqmponents
Components
1"=25.4mm
1. Clip (Ceiling Flange)
2. Hex Nut
3. Wood Screw
4. Hanger Rod
5. Adjustable Hanger
Ring
Application / Description
No. 5 Hangers are designed to support small piping from
smooth level wood planking that has a thickness sufficient
—to receive the- required fasteners. The hanger is secured to`
the planking by means of a clip (ceiling flange or hanger
flange) that is provided with a standard thread 1 r the rod
and holes for 2 wood screws. To prevent possibl loosening
of the rod due to vibration, the hanger is further secured by
a hex nut tightened against the clip.
There are 6 components in a basic No. 5 Hanger: The
clip, 2 wood screws, a hanger rod and locking hex nut, and
an adjustable hanger ring. The rod may be either all thread
rod (ATR) or machine thread rod (MTR). All thread rod is
considered to be standard, however. As a rule, machine
thread rod is provided only when it is a specific require-
ment of the job specifications.
No. 5 Hangers may also be used with other types of
construction of adequate strength when provided with
suitable fasteners — subject to the approval of the authority
having jurisdiction (AHJ). Deviations from standard fas-
teners are to be clearly indicated on the plan by detail or
in a hanger note (see Hanger Codes / Plan Designations).
NFPA Requirements / Limitations
NFPA 13 permits the use of 2 screw ceiling flanges only
for pipe sizes up to 2" and it calls for the use of screws
having dimensions not less than those of No. 18 x 1'/z"
wood screws. Drive screws and nails are not acceptable
fasteners and wood screws arenot to be driven.
,rev (Ai-ltr
5
`v
0
—I 0
AczkoN ?\O n
Design per NFPA 13, Extra Hazard
All materials to be new, U.L. listed, and F.M. approved
All fire sprinkler heads to remain unobstructed by lightings, ceilings, or any other means
All heads to be at least,6' apart
a 8 — Add Reliable Model G 212° Standard Response Uprights %2 x 1%2
o *Without Comments
Q As Noted in Red
Zi Per The Attached Letter
.':-e plans have been reviewed by The Tukwila Fire
;ration Bureau for'conformancf, with current City
',dards. Acceptance is subject TO =,rrors and
utons which do not authorize v!niatiops of adopted
rtis and ordinances. The rel oo sibiilty. for the
t,iaCy of design rests totally w,; ; rt,e designer.
:`,Ons, deletions or revisions to 'i . :;e drawings after
I = iO will void this acceptance '.i `iiia require a
i mlttal of revised drawings fp a :osequent approval.
acceptance is subject to flelc cst and •Inspection by
`i • ukwila Fire Prevention. Bureau,
By:
E
1 • UKW LA !IRE DEPAI9 I,ENT
Please call 2O6-575-4407nd
give this Fire Permit No.
/• 2.-3-07(1
Lid exact address for shut-
down or rest ration approval.
CROWN
FIRE. PROTECTION
INCORPORATED
P.O. BOX 121
MILL CREEK, WASHINGTON13 98082-0113
PH. (425) 481-7009
Pacific insulation Products
Chemical Storage Room
561. Strander Blvd.
Tukwila, WA
APR C D2012
TUKWILA FIRE
71 o 2oz
DATE: ' is q 11 Z I DRAWN: Q'
SCALE:
:/
�u�i.