Loading...
HomeMy WebLinkAboutPP - 647 STRANDER BLVD - UNKNOWN - PERMITS AND PLANS647 STRANDER BLVD ASSOCIATED PERMITS 11-5-220 98-F-165 Vito?)-\ SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 0223300020 Site Address: 647 Strander Blvd, Tukwila, 98188 Suite Number: Bldg E Floor: Tenant Name: Tukwila Commerce Center New Tenant? - Yes ❑ - No Property Owner's Name: CWWA Tuwkila 1 LLC c/o Kidder Mailing Address: PO Box 681897 Charlotte, CA 28216 CONTACT PERSON -if there are questions about the submittal. Name: Casey Walsh Day Telephone: 206.331.6206 Company Name: Guardian Security Systems Mailing Address:1743 First Ave South, Seattle, WA 98134 City State Zip cwalsh@guardiansecurity.com City State Zip E-mail Address: Fax Number: 206.628.4990 Total number of new/relocated devices or sprinkler heads: 1 Valuation of Project (contractor's bid price): $ 250.00 Scope of Work (please provide detailed information): Installation of an AES radio transmitter to monitor the existing FACP PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: Print Name: Casey Walsh Day Telephone: 206.331.6206 Plan Permit App.doc 1/2/13 TFD FP Form 8 FILE Seattle District Service Center Fire Alarm System Submittal PROJECT Pacific Gulf Properties, Bldg "D" (Computer Upgrades) Tenant Improvement 601 Strander Blvd Seattle, WA 98188 CONTRACTOR EST Service Contractors # EDWARDG045B9 647 Strander Blvd Seattle, Washington 98188 (206) 575-2911, Phone (206) 575-4898, Fax 647 Strander Blvd, Seattle WA 98188 p@MEME Al JUL 199P Phone: 206-575-6960 Fax: 206-575-4898 Pull ID) t Table of Contents Project Description Battery Calculation Sheets Fire Alarm Equipment Model Description BK -2400 Ionization Smoke Detectors BK -5451 135 Degree Heat Detector Rate of Rise BK RTS451 Remote Indicator Catalog Sheet Fire Alarm S stem Plans ACCEPTED O Without Comments ❑ As Noted In Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings atter this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 7/?/1J By: 571 TUKWILA FIRE DEPARTMENT Please call: 575.4407, nd give this job ..i ::x ,'Jdress for shut. u,.wn ur .+o.rt.,r.,Gon approv$I. Project Description Ref: Drawing FA -1 Customer is expanding into the adjoining suite, 605. Some of the warehouse area will become showroom. This division will require the additional heat detector and remote indicator for coverage. The new ceiling in the showroom will receive the additional smoke detector. The existing manual pull station and horn/strobe was not in the proper location for egress. It is being relocated for that reason. No other modification will be made to the system. Current system battery capacity will meet secondary power requirements. BATTERY CALCULATION FORM date: Job Name: Address: 7/1/98 Pacific Gulf Properties Bldg D - Tukwila Device Quantity STANDBY Current per device Current Standby Current Alarm Current _ALARM per device Silent Knight 5207 FACP 1 120 mA 400 mA 120 400 5210 Expander 1 40 mA 40 mA 40 40 mA mA 0 0 mA mA 0 0 mA mA 0 0 mA mA 0 0 mA mA 0 0 Current Subtotals (in mA) 160 440 Smoke Detectors Quantity _STANDBY_ Current per device ALARM Current Standby Current Alarm Current per device BRK-2400 Smoke Detector 60 0.12 mA 70 mA 72 4200 Heat Detector w/Remote 14 0 mA 44 mA 0 616 mA mA 0 0 mA mA 0 0 mA mA 0 0 mA mA 0 0 mA mA 0 0 Current Subtotals (in mA) 7.2 4816 Notification Appliances Quantity _ALARM_ Current per device Standby Current Alan Current Wheelock MIZ-24WM 25 127 mA 3175 Amseeco Bell 1 63 mA 63 Wheelock WS3T-24FR 0 115 mA 0 Wheelock Strobe 14 127 mA 1778 mA 0 mA 0 mA 0 Current Subtotals (in mA) 5016 Other l Additional Devices / / Quantity STANDBY Current per device _ALARM_ Current per device Standby Current Alan Current mA mA 0 0 mA mA 0 0 mA mA 0 0 mA mA 0 0 mA mA 0 0 mA mA 0 0 mA mA 0 0 Current Subtotals (in mA) 0 0 Total Current Requirements Standby Current Alarm Current Current rating of all devices in mA 167.2 10272 Current ratings converted to amperes (X .001) 0.17 10.27 Total Standby Current Total Alarm Current A Total supen►icory current from the attached calc sheet 0.17 A B Number of standby hours required (24 or 60) per NFPA 721-5.2.5 C Multiply Lines A & B 24 H 4.0800 AH D E Total alarm current from the attached calc sheet 10.27 A Alarm Sounding period (decimal eq) 0.084 H F Multiply Lines D & E 0.86268 AH G AddLinesC&F 4.9427 AH H Multiply G by 120% (Total aH req'd) 5.931216 AH Minimum Battery Required —> 5.931 Pacific Gulf Properties Building D July 1,1998 Decimel Minutes Equivalent 4 0.067 5 0.084 6 0.1 10 0.167 Suite 603 I� Reception Showroom Suite 601 L__ co f op I Office Suite 605 Reception Office Warehouse L) Office Warehouse • LEGEND SIMBOL DESCRIPTION DESCRIPTION MODEL MOUNTING INFORMATION PART NUMBER lin HEAT DETECTOR SYSTEM SENSOR BK -5451 MOUNTS TO 3/0 OR 4/0 RING I REMOTE INDICATOR SYSTEM SENSOR BK-RTS451 MOUNTS TO SINGLE GANG RING © SMOKE DETECTOR SYSTEM SENSOR BK -1400 MOUNTS TO 3/0 OR 410 RING General Notes: 1. Redlines Indicate Walls that will be removed or installed. 3. All fire alarm installation work will be performed by EST Services. 2. Wiring will above ceiling FPLP open wire. Installed per applicable codes 4. "N" Indicates devices that wil be added to the system. 5. Wireing will be 18awg FPLP solid, 4 conductor SCALE: None DATE: June 29, 1998 DRAWN: ELM APPR: ELM JOB NUMBER 7450-9806-20-330 :"711 PROJECT CONTRACTOR EDWARDS SERVICES - SEATTLE DISTRICT OFFICE 647 STRANDER BLVD, SEATTLE WASHINGTON 98188 PHONE. 206-575-2911 / FAX 206-575-2933 CortsartorLorms # REVISIONS REV DESCRIPTION DATE APPR SHEET NO. FA -1 Pacific Gulf- Com Upgrades 601 Seamier Blvd Seethe, WA 98011 FIRE ALARM DEVICE LAYOUT (ef 54a-e‘i,( 64i/ 51- -e- 1, 1 r burct fk L- (,) f 1_0 c\I ch. NORTHWEST FIRE SYSTEMS Saving lives, Protecting Property September 28, 2011 Al Metzler Tukwila Fire Dept. 444 Andover Park East Tukwila, WA 98188 Project Name: Miracle Ear Address: 647 Strander Blvd Tukwila, WA 98168 Dear Al, TUKWILA FIRE DEPARTMENT call 206-575-4407 and give this Fire Permit No. and exact address for shut- down or restoration approval. Please accept this formal request for permission of system shut -down for the following scope of work: • Replacement of fifteen (15) sprinkler heads with new code compliant quick response sprinkler heads in the Miracle Ear space. • Extension of three (3) sprinkler heads for proper placement of new QR semi - recessed sprinkler heads. • Note: No heads will be relocated, added or deleted per this scope of work. Ie: Coverage will remain the same and hydraulic calculations will not change. This is a formal request for shut -down authorization for the above-mentioned scope of work. Please from the proper shut -down number and any other instructions for the proper completion of scope of work so that local codes are upheld. Sincerely, Aaron Potter Service Manager Northwest Fire Systems 3315 South 115th St • Ste 115, Tukwila, WA 98168 • Office: 206.772.7502 • Fax 206.772.7504 • www.nwfiresystems.com 1-1)