Loading...
HomeMy WebLinkAboutPP - 14626 MILITARY RD S - BERRE'S AUTO - PERMITS AND PLANS13-F-051 14626 MILITARY RD S ASSOCIATED PERMITS 91-236 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** OaoU King Co. Assessor's TaxNo.: 0040000828 Site Address: 14626 Military Road South Suite Number: Floor: Tenant Name: Barre ' s Auto New Tenant? ❑ - Yes [C. No Property Owner's Name: Joya Jorge Mailing Address: Po Box 69315 Seattle WA 98188 CONTACT PERSON -if there are questions about the submittal. Name: Kristopher Conner City State Zip Day Telephone: 2 5 3- 7 5 3- 6660 Froula Alarm Systems, Inc. Company Name: Mailing Address: 861 Industry Drive Tukwila WA 98188 E-mail Address: kris@froulasolutions.com City State Zip Fax Number: 206-575-8168 Total number of new/relocated devices or sprinkler heads: 6 Valuation of Project (contractor's bid price): $ 2, 500.0 0 Scope of Work (please provide detailed information): Install fire alarm in small office PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 0 AUTHORIZED AGENT: Signature: 1 Date: zit -L/13 Print Name: Kristopher Conner Day Telephone: 253-753-6660 Plan Permit App.doc 1/2/13 TFD FP Form 8 1 c".' heat in atti above 0 M33:001 110 cd F r 75 cd M33:004 RA FIRE ALARM PLAN SCALE: 1/4 = 1v-0" ATTIC 1ST FLOOR RISER DIAGRAM SCALE: NTS BatteryCak:ulation Worksheet tall currents stated in mA) Device Description # of Devices mA Draw each Total mA Draw Stand By Alarm Stand By : Alarm RAr1000 IDP -PHO IDP -HEAT IDP-PUL4SA Unused System Devices #I 20 Total System Current v:;f:> °.. Initiation Devices 1 Auxiliary Devices Device Totals 0 a Notification Appliances (list all) P2R w 110cd SR@ 15cd P2RK @ 75cd' NAC 1 201 unused -0#0.01011:04101:9;60:10,: NAC 2 176 . Circuit3 Tata . 4 Unused unused Qj t ircult4 Totals: a ,:Notification Appliances Total. Currentin n tASIMEMMESS Design Voltage 24 Voltage Drop Calculation Worksheet Circuit #1 Length 80 Amp Draw 0;443 Wire Gauge 14 Loss per 100 Voltage Drop Voltage at EOL 0.22 0.18 23.82 Voltage Drop 0.74% Circuit #2 Length 0 Amp Draw D Wire Gauge 14 Loss per 100' 0.00 Voltage Drop 0.00 Voltage at EOL 24.00 Voltage Drop 0.00% Circuit #3 Length Amp Draw Wire Gauge 14 Loss per 100' 0.00 Voltage Drop Voltage at EOL 0.00 24.00 Voltage Drop 0.00% Circuit #4 Length Amp Draw Wire Gauge Loss per 100' Voltage Drop 14 0.00 0.00 Voltage at EOL 24.00 Voltage Drop 0.00% Summary Section Required Standby Hrs. 24 Alarm Sounding Minutes 5 Total System Standby mA 202 Available 9000 Total System Alarm mA 770 9000 Total System Standby Ah 4248 7 Total System Alarm Ah 0.064 Min. Ah Battery Derating Factor 4.912 20% BatteryAh 5.895 -o-.u•. - .3'' - 'w arvX>�� .ry x:�<�..`wf��`�.�<.��.��!��c.Y,t�.e�:��,<s�3. sx�'c'_.�'�•',�',�`";Y.,. ®BATTERY CALCULATIONS SCALE: NTS 7 7 NOTES: 1) ALL WORK TO CONFORM TO NFPA 72 AND NEC STANDARDS 2) WALL MOUNT HORN STROBES AND STROBES TO BE MOUNTED 80"-96" AFF OR 6" BELOW CEILING WHICHEVER IS LOWER. 3) PULL STATIONS TO BE MOUNTED: A) 48" - 53" AFF B) WITHIN 5' OF THE DOOR. 4) FIRE ALARM CONTROL PANEL TO BE ON DEDICATED CIRCUIT 5) WIRING METHOD TO BE OPEN CABLE UNLESS BELOW 7' AND EXPOSED, THEN IT WILL BE CONTAINED WITHIN CONDUIT. 6) SMOKE DETECTORS TO BE INSTALLED: A) MORE THAN 36" FROM ANY HVAC DIFFUSER B) NOT IN CLOSE PROXIMITY TO FLUORESCENT LIGHTING C) AT LEAST 6" DOWN FROM PEAK IN SLOPED CEILING 7) ALL JUNCTION BOXES, MUD RINGS AND BOX COVERS TO BE PAINTED RED (INSIDE AND OUT). 8) EXTERIOR HORN STROBES TO BE MOUNTED IN THE TOP 2/3 OF THE BUILDING STRUCTURE FACING THE ANTICIPATED FIRE DEPARTMENT ACCESS ROAD. NOTES SCALE: NTS SYSTEM OUTPUTS SYSTEMS INPUTS SEQUENCE OF OPERATION 1l ALARM MATRIX CONTROL UNIT ANNUNCIATION NOTIFICATION REQUIRED FIRE SAFETY CONTROL SUPPLEMENTARY Equipment Legend Symbol Quantity Part Number Description Back Box 1 IFP -50 Fire Alarm Control Panel Included 3 2 RA -1000 Remote Annunciator Included RA O1 IDP -Photo Photoelectric Smoke Detector 4" Square O2 IDP -Heat Heat Detector 4" Square 1 IDP -Pull -SA Manual Pull Station 4" Square F El 1 P2R Wall Mount Hom Strobe 4" Square P2RK Outdoor Hom Strobe Included R1 1 SR Wall Mount Strobe 4" Square tom' WIRE LEGEND A- 18 GAUGE 2 CONDUCTOR 'FPLP' B- 14 GAUGE 2 CONDUCTOR 'FPLP' C- 18 GAUGE 4 CONDUCTOR 'FPLP' D- 14 GAUGE 4 CONDUCTOR 'FPLP' A 0 C D; E F G H J K L M N 0 P R S T u Manual Pull Station X X X X x 2 Smoke Detectors x X X X x 3 Heat detector X X X' X X 4 NIA 5 NIA 6 N/A 7 N/A 8 N/A 9 N/A 10 N/A 11 N/A 12 Short Circuit X X X X 13 Ground Fault X X X 14 Open Circuit X x x x 15 Notification short circuit X X X X 16 WA 17 N/A 18 N/A 19 N/A 20 WA SEQUENCE OF OPERATIONS SCALE: NTS Without CommantS As Noted in Red - p Per The Attached Letter These plans have teen reviewed by The Tukwila Fire Irevefltion Bureau for conformance with. current City nci irds. Acceptance. is subject to errors and n loris whirs i ' at authorize violations of adopted •-•:73hdards anti ordirs. The responsibility for the ,'Totem, y o, The r is totZiliy with the designer. t till:lori it R e `,1 t-• r . i for ss to these drawings after .r:i epeiice and will require a r subrnitta(,!: a:.v Ings for subsequent approval. 'Ina! acceptance is si'o ect to field test and inspection by fie Tukwila Fire Prevention Bureau. - ,: te.3=.tr - I'S • ....�By: Ivokrit\ bregker-h/'Stid1�t/Ckb... 7 o►4 ckeckit4Uc�( PA- .w..� c� LJyt8 tr. �f J.hs�Gi� •�•rvc (4111-. /6,0,4 ke/ 1J' p.7C TUKWILA FIRE DEPARTMENT PieBse Cali 45-575-4407 407 and give this Fire Permit No. and exact address for shut- dnwn or restoration approval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing,, -- PA1D----...__ FEB 22 2013 TUKWILA FIRE e2L '..ov' FRt�U L�► ALARM.,$YInc.n': Froula Alarm Systems, Inc. 861 Industry Drive Tukwila, WA 98188 206-575-1962 DESIGNER OF RECORD Kristopher Conner NICET IV 69311 0 00 (40 o��� o Q jit) E.' .� to m � Y F- w41- it - 1 E DATES SUBMITTAL: 14 Feb 2013 REVISION: SHEET TITLE FIRE ALARM PLAN SHEET NUMBER FA -1 • EO► - t -F 4 L Frac, P I3° CZ. PrC aF tis tb5i L (c3 D t R tt5 a.. t_ P u. L. 1. 3 iA-Zara D rn Ni N Q ;t N (3iz) J �7Plit"fr hirfr'11(4°i-o„,4-) elapt • ACCEPTED ❑ WITHOUT COMMENTS VS NOTED IN RED ❑ DER LIE ATTAC- ED LETTER The dr1 %lags a ii e`1 n:rct3 ha 'e been regi. v i ;;1-J acc:•, 4-3..1 Ly 1,13 C1 y or T u'S'. h F 1i 3 D3pt Fh1.: ''iD"3 c l:,',l3ns or r ; l lThc 13 t) +17.23 Cr.?,'",3 or r us %I .. �'� �t 1 ‘,31.2, ti jai �Cc`'. -'''_A1,3 c, i i N 1 Itri.Cj,liru N I4.3..1...Yo1 `�l `v1 iari.,..., Final a ,ceptan:e 13 s'n ^::.+ t3 ;i '1 In3p£cI'3ri ay a repreQcnLaUre of L1i* dap:ttrcnt -9 DATE a/ BY CITY OF TUKILA 575 4407 TUKWILA FIRE DEPARTMENT Please call. 575-4407 and give this job No. Il z 3(‘/ and exact address for shut. down or reaCioratign swamis @EIllal AUS 5 1991 -SEAri Lr~ TC.:}... RI4i TRAL.-TOit t' -162b mxLzTAd SCALE '['i DATE L.. el APPROVED BY 1.2,RAWN BY REVISED NAte'%OwAL. izAteA{LL):`,A,J .31332 l b k Ac.isr. cJ ScartLE: 'int9 A IA -1 b '1 S . -r .v. Ps a c ALA 114 DRAWING NUMBER PRINTED ON NO. 1000N CLEARPR1Nr. - -44 1 rw X245/