Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 14816 MILITARY RD S - VALLEY VIEW SEWER DISTRICT - PERMITS AND PLANS
08-F-441 14816 MILITARY RD S ASSOCIATED PERMITS 08-F-400 00-F-156 Off Etre/t'arking Area Dimensions TMC 10.86.040 A D C D E F Parldng Stall • Stall Ale/e WidthCurb 0 link Wirth 1 Way 2 Way 1 Way 2 Way Angle Width Depth Length Tratfic Traffic Traffic Truffle 0' r r 12 20 20' 29' 36' 8.5 5.5 12 20 23 29 37 30° 5* 15' 11 20 16' 41' 54' 5,6 17 11 20 17 45 54 9 17.5 11 20 15 46 56 9.5 15 11 20 19 47 56 46' r it 12.5 20 11.6' 46.5' lie 85.5 19.5 12.5 20 12 51°.5 59 9 20 12 20 12.7 52 6o 9.5 20 12 20 13.4 52 60 60° 4 16' 17.5' 20 92' 53.5' 56* 5,5 21 17.5 20 9.5 59.5 62 9 21 17 20 10.4 59 62 9.5 21 15.5 20 11 55.5 62 r 16' 24 25 r or 57' 5.5 19 24 25 0.5 42 63 9 19 23 24 9 61 62 9.6 19 22 24 9.5 60 62 • These Was ale for i O with compact oars wdf►. NW boys that canto n combined compact and nomad spaces shelf ba deaig sd for nomrl spaces. Ipleca,d c.4 I ocq:1 LQ"''q4e- PROJECT INFORMATION PROJECT ADDRESS: TAX PARCEL NO.: LEGAL DESCRIPTION: AUTHORITY HAVING JURISDICTION (AHJ): OTHER PERMITS: PRE -APPLICATION #: MUP/ACUP #: 14816 Military Road So. Tukwila, Washington, 98168 004100-0083; 0088; 0089 LOT 4, BLK 2, OF FIRST ADDITION TO ADAM'S HOME TRACTS, ACCORDING TO THE PLAT RECORDED IN VOLUME 12 OF PLATS, PAGE 50, IN KING COUNTY, WASH; EXC THE EAST 60 FT; EXC THE NORTH 10 FEET RECONVEYED TO KING COUNTY FOR ROAD. CITY OF TUKWILA ARCHITECTS P,S L08-004 PRE -07-021 910 MARKET STREET KIRKLAND, WA 98033 TEL: 425.827.7850 FAX: 425.827.7014 INFOOPAGEANDBEARD.COM STALL LAYOUTS O i nese plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subiectto errors and omissions which do not authorize violations of adopted stanaaras and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions,or revisions to these drawings alter this date will void thie.acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field testand inspection by The Tukwila FirePrevention Bureau. 1? -2/0 5 10 2- y v r , 4' -w �c In We ser- I 4- "Al`t0s- oSSIcuLY5 9-55 c F ir. CQ 1MUJ F t 2E_ 1 -A -t-40- 1K% .Fez O c =rJ ) \FZo-cnn int; to A-o u.)e 54- __ } Cyv. tM i 1 ;1}-w 0 174.35' OWNER: ARCHITECT: VALLEY VIEW SEWER DISTRICT PAGE & BEARD ARCHITECTS: STRUCTURAL DIBBLE ENGINEERS, ENGINEER: INC CIVIL ENGINEER: PACE ENGINEERS SURVEYOR: PACE ENGINEERS ELECTRICAL ENGINEER: AWA ELECTRICAL MECHANICAL ENGINEER: LANDSCAPE ARCHITECT: FIRE DISTRICT: WATER DISTRICT: SEWER DISTRICT: -------- 349- S. 1 48TH STREET 40' SIGHT TRIANGLE 148TH FRONTAGE IMPROVEMENTS. SEE CIVIL PLANS NE\ W FRESTE ANDING SIGN W/ GROUND MNTD LIGHTS -SEE ELEC. SIGN IS N.I.C. EXIST CONTOUR LINE, TYP. SEE CIVIL FOR GRADING NEW CONTOUR LINE, TYP. SEE CIVIL FOR GRADING 447 SF CONSULTANTS, INC Fsi CONSULTING ENGINEERS LAUCHLIN BETHUNE LANDSCAPE CITY OF TUKWILA K.C. WD # 125 VALLEY VIEW SD (206) 242-3236 (425) 827-7850 (425) 828-4200 (425) 827-2014 (425) 827-2014 (425) 775-1799 (206) 622-3321 (425) 432-9877 (206) 575-4404 (206) 242-9547 (206) 242-3236 BUILDING INFORMATION CONSTRUCTION TYPE: SPRINKLER SYSTEM: FIRE ALARM: STANDPIPE: OCCUPANCY GROUPS: EXIST BUILDING A V -B NO YES NO B, S-2 BUILDING B V -B NO YES NO EXIST BUILDING C V -B NO YES NO B, S-2 USE: Public Utility Operations & Yard (18.24.020,33,c; 46) BUILDING GOES: 2006 IBC, 2006 WAC 51-50, 51-11, 51-13 ENERGY CODE & 2006 WASHINGTON STATE NON-RESIDENTIAL ENERGY CODE COMPLIANCE OPTIONS: (REFER TO ENERGY NOTES ON A-0.0) PROPOSED BUILDING AREAS: (SF) EXISTING 2850 PROPOSED NEW SECOND -BUILDING B TOTAL 0 GROUND -BUILDING A THIS DOCUMENT REPRESENTS A PROPRIETARY 2690 SHALL NOT BE USED ON OTHER PROJECTS 0 COMPLETION OF THIS PROJECT BY OTHERS 2690 SECOND -BUILDING A 5329 REGISTERED 1340 GALEN C. PAG E 0 1340 TOTAL BUILDING A GROUND -BUILDING B 0 2850 2850 SECOND -BUILDING B 0 0 0 TOTAL BUILDING B TYPEI EXIST LP STORAGE TANK TO REMAIN GROUND -BUILDING C 2352 0 2352 SECOND -BUILDING C 0 0 0 TOTAL BUILDING C R 10.00' 311° 29' 49" EXIST 8" DIA BOLLARDS TO REMAIN PORTABLE \1 E 24 FIR. SITE AREA RC ZONE 48,884 w 347._ EXIST CONC "ECOLOGY" BLOCKS TO REMAIN COVERED ENTRY ETC TOTAL BLDG LOT COVERAGE EXIST PORTABLE SHED TO REMAIN NEW MOTOR OPERATED CANTILEVERED ROLLING GATE (WIRELESS REMOTE & PEDESTAL MNTD KEYPAD CONTROLS) ALLOWABLE BLDG SIZE -NEW BLDG B: PER IBC TABLE 503 GROUP U: 5,500 SF (TABLE 3,000 SF (IBC 406.1.2; USE 406.1.2 503) NEW MOTOR OPERATED CANTILEVERED ROLLING GATE (EGRESS ONLY) TREES @ 30' O.C. @ TYPE I BUFFER. SEE LANDSCAPE PLANS FOR ACTUAL LAYOUT & ADD REQMNTS 114.00' ASPHALT/GRAVEL AREA A: 27,396 sq ft MATERIAL STORAGE YARD 20' WIDE "NO PARKING -FIRE LANE" PAINTED ON ASPHALT AS REQ'D BY TUKWILA FIRE DEPT. NEW 6' TALL CHAINLINK SECURITY FENCE W/ BLACK VINYL FABRIC, FOLLOWING NEW CURB, TYP. UNO 4" CONC WALKWAY W/ LIGHT BROOM FINISH, TYP. ALT # 1: RAINWATER CISTERNS (3) 4" CONC WALKWAY W/ LIGHT BROOM FINISH, TYP. ASSUMED PL BTWN BLDGA&B L T I I %\ \\=\� BUILDING B -NEW VEHICLE STORAGE BUILDING V - V•\ OCCUPANCY TYPE EX. BLDG. A: FACTOR (1 / "X" SF) AREA (SF) GARAGE 200 1160 OFFICE 100 2870 TOTAL OCCUPANCY: NEW BLDG B: OCCUPANCY LOAD 5.8 28.7 35 GARAGE 200 2850 TOTAL OCCUPANCY: 2,150 sq ft PLANTING' WHEEL @ NOR ING= TOPS, H STA CARPORT/ 700 sq ft iiiimiummtm iirrA', iii BIKE RACK T ' (1) _ [� I\ 433 433 SF fV -0 1 10' X 30' LOADING BERTH STRIPING AREA OF POSSIBLE FUTURE ADDITIONS TO BE KEPT CLEAR OF ALL NEW U.G UTILITIES, ETC. EXIST 60Kw GENSET, GAS METER & COVERED ENCLOSURE. EN WVAC-UNITS-SEE_IECIi EXIST STOREFRONT -STAIR ENCLOSURE TO REMAIN. NEW TYP. 6' TALL CHAINLIN SECURITY FENCE W/ MAN -GATE 8.50' 8.50' 8.50' 8 1 ASPHALT PARKING LOT 8, 1 ' A: 4,545 sq ft L 8.00' 8.00' BUILDING A - EXIST OFFICE / SHOP MINOR REMODEL UNDER THIS PERMIT APPLICATION BLDG C- EXIST SHOP NO WORK RELOCATED FLAGPOLE W/ NEW LGHT FIXTURE -SEE ELEC 2,690 SF LOT COVERAGE 2,371 SF LOT COVERAGE 1 HR FIRE RATING OF WALLS WITHIN 5' OF PL TO BE VERIFIED IF/WHEN GARAGE ADDITION PERMIT APPLICATION SUBMITTED. (7) ST LLS BSB BUFFER' TYPE' I 0.230 eqE 10.00' PLAN ING 21 F O 0 of COMPACT O 0 PLANTING - 418 SF rm. NEW CONC CURB, TYP. I .1 ; I ITREES @ 20'O.C. @ TYPE II BUFFER; SEE LANDSCAPE PLANS TYPE II EXIST WALL MNTD LIGHT FIXTURES ON BLDGS A & C TO BE REPLACED W/ NEW SHIELDED HID FIXTURES. SEE ELECTRICAL PLANS. NEW CONC WALKWAY EXTENSION. EXIST CONC WALKWAYS TO REMAIN 00 w S87°56'05"E 254.17' N m NEW CONC PATIO -SEE ALT # 2 DEMO'D DRIVE TO BE REPLACED WITH - NEW TYP. 6')TALL CHAINLINK SECURITY LANDSCAPING @ AREA - SEE LANDSCAPE FENCE W/ MAN -GATE DWGS 81.52' / I \ )__62.53 6,53' NEW c P 6' TALL CHAINLINK FENCE ' 1 ADJACENT ZONE: RC 57.74_ V 110.12' EX 8' TALL CHAINLINK SECURITY FENCE, TYP. NOTE: SEE CIVIL, LANDSCAPE, ELECTRICAL & MECHANICAL PLANS FOR ADDITIONAL INFORMATION AND REQUIREMENTS. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. INFORMATION CONTAINED ON ANY INDIVIDUAL PLAN IS TO BE CONSIDERED CONTAINED IN ALL. SITE PLAN SCALE: 1" = 20' SITE & ZONING INFORMATION PROJECT ADDRESS: 14816 Military Road So. Tukwila, Washington, 98168 TAX PARCEL NO: 004100-0083; 0088; 0089 LEGAL DESCRIPTION: SEE "PROJECT INFORMATION" ABOVE ZONING: RC -Regional Commercial LOT SIZE AND COVERAGE: LOT AREA: ALLOWABLE LOT COVERAGE: N/A NON-PGIS (ROOF AREA): PGIS (ROOF AREA): PGIS (DRIVEWAY, PARKING): NON-PGIS (WALKS, CONC PADS): TOTAL LOT COVERAGE: TOTAL PGIS USE CLASSIFICATION: Public Utility Operations & Yard BUILDING SETBACKS: Front: Second front: Side: Rear: BUILDING HEIGHT: Max. allowable height: Additional height: REQ'D LANDSCAPING: Front: Second front: Side: Rear: Parking Lot: PARKING STALL SIZES: Large: Medium: Compact: Loading berth (TMC 18.56.060): PARKING REQUIRED: Office use: Warehousing: Total Parking req'd: Parking Provided: Loading berth(s) req'd: 1 loading berth Bicycle Parking req'd: 1 / 50 stalls; 2 min 48,884 6198 2504 31940 1124 41766 34444 Tukwila Municipal Code 18.24.080 20 feet 10 feet 10 feet No yard is within 50' of LDR, 10 feet No yard is within 50' of LDR, Tukwila Municipal Code 18.24.080 3 stories or 35 feet N/A Tukwila Municipal Code 18.24.080 10 feet: Type I 10 feet: Type I 5 feet: Type II No yard is within 50' of LDR, none No yard is within 50' of LDR, Per Design Review req'mnts Tukwila Municipal Code Figure 18-6 9' & 9.5' X 19 24' 2 -way aisle @ 90° 8.5' x 19' 25' 2 -way aisle @ 90° 8' x 16' 25' 2 -way aisle @ 90° 30% max 10' x 30' MDR, HDR MDR, HDR MDR, HDR MDR, HDR BID SET JOB NO: 07.15 DATE: 5/15/2008 REVISIONS: Q4/11/08 DESIGN REV COMMENTS THIS DOCUMENT REPRESENTS A PROPRIETARY DESIGN OWNED BY THE ARCHITECT AND SHALL NOT BE USED ON OTHER PROJECTS FOR ADDMONS TO THIS PROJECT OR FOR COMPLETION OF THIS PROJECT BY OTHERS EXCEPT BY PRIOR ARRANGEMENT IN WRITING © PAGE & BEARD ARCHITECTS, PS 5329 REGISTERED VI ARCHITECT GALEN C. PAG E STATE OF WASHINGTON Tukwila Municipal Code 18.24.080 & Figure 18-7 3/1000 SF 2870 1/2000 SF 6362 SITE PLAN 3,000-100,000 SF 8.61 3.18 12 14 1 SHEET; FIRE ALARM SYSTEM TUKWILA, WASHINGTON SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET \ UN 3ESHEET TITLE FA -01 SYSTEV I\ FO v1ATI O \ FA -02 TYP. WRING & MOUNTING DETAILS, CALCULATIO \S AND FA -03 3UIL3I\G 3 \EW VEHICLE STORAGE FRE ALAN PLAN WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D DATA LINE -ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) H DOOR HOLDER POWER - 24VDC TWO #14 FPL/FPLR RED (JACKET) P DEVICE POWER - 24VDC TWO #16 FPL/FPLR RED (JACKET) S STROBE CIRCUIT - FEED TWISTED PAIR W/ SHIELD #12 FPL/FPLR RED (JACKET) A ANNUNCIATOR TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) V SPEAKER CIRCUIT - FEED TWISTED PAIR #14 FPL/FPLR RED (JACKET) I REMOTE INDICATION LIGHT TWO #18 FPL/FPLR RED (JACKET) X LOW LEVEL AUDI❑ TWISTED PAIR W/ SHIELD #16 FPL/FPLR RED (JACKET) UD UNDERGROUND DATA TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) UI UNDERGROUND INITIATION TWISTED PAIR RATED #18 FPL/FPLR RED (JACKET) M DOOR HOLDER POWER TWO #16 FPL/FPLR RED (JACKET) B BEAM DETECTOR POWER TWO #14 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 2. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 3. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 4. INSTALLATION MATERIALS (LE. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. 5. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 6. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 7. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. 8. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. 9. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 10. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 11. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 12. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 13. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 14. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 15. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 16. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 17. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 18. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 19. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (LE., MULTI -CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 20. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MIN MUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 1 1 12 2 1 3 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM CONTROL PANEL MS92000DLS FIRELITE PROVIDED 66" A.F.F. TO TOP SMOKE DETECTOR SD355 (ADDRESSABLE -PHOTO) FIRELITE 4S BOX W/ 1G RING CEILING HEAT DETECTOR (ADDRESSABLE) H350R FIRELITE 4S BOX W/ 1G RING CEILING 0 MANUAL PULL STATI O N BG-12LX FIRELITE 4S BOX W/ 1G RING 48" A.F.F. TO CENTER DUAL SYNC MODULE DSM- WHEELOCK 4S BOX VERIFY 12/24-R IN FIELD FIRE ALARM HORN STROBE ZNS-MCW -FR WHEELOCK 4S BOX 80" A.F.F. TO BOTTOM FIRE ALARM STROBE (WEATHERPROOF) RSSWP- WHEELOCK WPSBB-R VERIFY 24MCWH-FR IN FIELD 8WP FIRE ALARM BELL (WEATHERPROOF) MB -G10 WHEELOCK WBB-R VERIFY -24-R IN FIELD JUNCTI❑N BOX F.B.O. F.B.D. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A = ; N/A N/A N/A U.O.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A z 1 Without CGrrtmfit1ts As i\iot:.a In Re Per Th,-/ fi .; ,j J^ �S�G: 'fi lir. !nese plan have Prevention r,U.:.... lc_ . standards. AC+:, omissions wh ch Fire city stanaaras and oroim.Inc.,..s.. adequacy of rfe ., ,h r rr, , it`, ttt rih 'r. Additions, deletions 14 i r F (ert;wi "iii attar TUKWILA FIRE DEPARTMEDI Please call: 575.4407 and give this job a , ! ire 3s for shut. ut,w„ ur restoration approval. NOTICE ornpieted, signed, Tukwila Fire Department Pre-test rtificate must be presented to the Inspector prior to mmencement of Acceptance this date v;'iil vaiia tt� �: i },, , 0 � ,� r&.10(-;. Testing of any Fire. Alarm resubmittal of revs _ d c:i ,.r .. icy: 1o+ sub ; querlt approval. and Detection Systems. Failure of test will result Ina Re -inspection Fee and termination of the testing. Final acceptance is subject to field test and inspection b‘ The Tukwila Fire Prevention Bureau. Date: 9 -3 -OS By: /V vt S7 ( Xn C ANT E\' 1„».1-7,17:.[-E Because of incased demand our inspectors' schedules are booked 3-7 days ahead. Therefore, you will need to call 206-575-4407 to schedule your inspections a minirnum of hours in advance of _,«- you want an insp?th'en. J hs4 i1 :1/4:0,4:30d)cevite o' FA dedI'C4 hv',4 o',�}- art4Ye S es cv ce4,4%„( FILE COPY PAID AUG 20 20081 c; rc).a- bre4t • Tukwila Fi I 70 right 2006 by Guardian Security Systems, Inc. All Rights Reserved 0-5 0' FAX (206) 628-4990 RELEASE/REVISIONS IREV. BY: NVI DESCRIPTION SHOP DRAWINGS DATE m a 0 0 2aa<aa z 0 V CC 1-- E0co w Qs°, 0 W >- 21-5 fag z J W c \ W J J UJ >ii CI) SCALE: 1 /8"=1 DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/ 12/08 BACKROUND PLAN PROVIDED BY: ..JOB NUMBER: SHEET FA -01 EOL—S2 EOL—S1 0 0000 00 0 0 0 El 1:1 0000 0000 111111111111 I 000 000 000 0000 00 0 00 0 0 (lu(((ll 0 0000 00 0 0 0 .01 CI 00®000 0 00000000000 0 000000000000 0 O � O 0 0 a 0 0 M• r DEM 00 MD 0 ODD 00000DD00 O = O 0 = 0 = 0 0= _ =ISI 0 = = • 0 0 = = 0 0 = =0= 0 a 0 isz n u gone om ,__1 ocnnoo DDDDDD 0 f 110 C 15 C 15 C 15 C 110 - s v s v s v s• 75 C 75 C 15 C 110 W WP FIRELITE MS92000D CONTROL PANEL SCALE:NONE El 11) 6) i)1(41Dii 1:1 D D D 0 D JUNCTI❑N BOX MOUNTED ON CEILING SLAB 0 0 0 0 JUNCTION BO} MOUNTED AGA CEILING SUPP NST )RT .0_ \DJ SMOKE/HEAT DETECTOR 1 SMOKEIHEAT DETECTOR MOUNTING SCALE:NONE TO NEXT DEVICE SUSPENDED ILLUMINATED CEILING HORN STROBE I STROBE WIRING DIAGRAM LABEL SCALE MANUAL PULL STATION ©48" TO PULL 4" SQUARE DEEP BACK BOX WITH 1G TRIM RING HORN/STROBE R E 80" A.F.F. WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS SCALE:NONE 0 ELL • 4S DEEP BOX MANUAL PULL STATION SCALE:NONE MANUAL PULL STATION ©48" TO PULL 4" SQUARE DEEP BACK BOX WITH 1G TRIM RING TO NEXT DEVICE O 0 O 0 3 JUNCTION BOX MOUNTED AGAINST CEILING SUPPORT \FIRE( CEILING HORN/STROBE C❑MBINATI❑N CEILING HORNISTROBE COMBINATION SCALE:NONE FROM PRECEDING APPLIANCE, FIRE ALARM CONTROL PANEL (FACP) I n, WETHER PROOF BELL SCALE:NONE TO NEXT APPLIANCE OR END OF LINE RESISTOR (EOLR) SUSPENDED CEILING TYPICAL WIRING AND MOUNTING DETAILS Valley View Battery Pair to be Used: Total System Current Load: 12VDC Amp -hours Current Load: ZNS-MCC @15CD ZNS-MCC @75CD MB -G10 -24-R Valley View MS-9200DLS Standby: Alarm: Battery Pair to be Used: Total System Current Load: 12V DC Amp -hours 0.189 0.03 Amps 0.378 0.030 1.87 Amps PROJECT: VALEY VIEW Panel: i BPS CIRCUIT: S1 1 i ZNS-MCC @15CD ZNS-MCC @75CD MB -G10 -24-R Notification Appliance Circuit Detail 65 189 30 65 378 0 0 30 'Wire Resistance 1.62 ZNS-MCC @15CD ZNS-MCC @75CD MB -G10 -24-R DEVICES="E 65 189 30 m, 195 0 O 0 9463514' i83' (Total Cct Load (20.4 - E WL*2)*(R/ft) (Total Cct Load =1*R) (20.4 - Cc" 2 oQ 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z a DESCRIPTION SHOP DRAWINGS DATE 03 0 tn in zaaaaa 1 0 cc (1) O co cc E W Q°° V) 0< cn LLJ W M� 5LLH W J J IC —J U_ C .GALE: 1 /8"=1' DRAWN BY: (.ANDERSON DESIGNED BY: R.VEZZANI DATE: 5/ 12/08 BACKROUND PLAN PROVIDED BY: SYSTEM CALCULATIONS .JOB NUMBER: J SHEET Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved FJ\ -02 v ,D • o— S xLt?:.A..T Er) Ho o—D fay. G= ,�, �`�� 7 i� E)<S'r ALARM "7 G S E Up -ii RAE) ED AS \ frs: Y0 02 , ["1.70N OF UP,tYN, 2 \ F u N ;tel ' EuRR/ o- -D FA/PANNEL I ' H .__D E l' , ....J \� R,)7 \. / 111 l_ O` EM'S ref / EXIST" GPRAU / 110\ N' D ET SI'n� AREA v� ai a t; �. r pc.5 XT.S1— STAIRWEl..L — Try NORTH BLDG. A FIRST FLOOR PLAN SCALE 118"=1' EX1ST _ .I RO0 h/1 i 1 1.4)1_ TO FLOOR 1 W V-{ j1_.t_ '.s9.r1'D S-11 12,J1s,"rt_st T-0 ROOF CA T C -? ;13 v 14y>' 3/ q &CX PL r/ D fl RGKfJ . uh11" ( R.DK CW8 TO 3 ST(J0SS inti 1 D kr� Q M ENE.RRGEO OEFI`EflA_OCAT ED S n,rc cw 6 ,Tri SPACKLE 3' En S E/T E�XI/1�7p �c LaEXLS�- OFFICE f ` I f I I ® y LI D I NORTH _ 0 • BLDG. A SECOND FLOOR PLAN SCALE 1/8":1' PLANS NOT APPROVED DO NOT INSTALL ADDRESSABLE INITIAT NG DEVICES UNTIL P-REPROGR,• DINED WITH DEVICES ADDRESS. Copyright 2006 by Guardian Security Systems, Inc. All Rights Reserved FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS REV. BY: z 4 DESCRIPTION I SHOP DRAWINGS in I - a c3 5/15/08 U F/" w / , 0 WOco o w oar 0‹ pc pQS W=� W cc Mo 5UH W J J `�CALE: 1 /8"=1 DRAWN BY: LANDERSON DESIGNED BY: R.VEZZANI DATE: 5/ 12/08 BACKROUND PLAN PROVIDED BY: \0B NUMBER: 1 SHEET FA -03 M:\Drawings\Valley View Sewer District\FA Dwgs.dwg, FA -01, 7/30/2008 11:54:29 AM, dgarcia, ARCH D (24.00 x 36.00 Inches), 1:1 FIRE ALARM SYSTEM TUKWILA, WASHINGTON SHEET INDEX GENERAL NOTES SYMBOLS LEGEND SHEET \UIV BES SHEET TITLE FA -01 SYSTEM I \ FOMATIO\ FA -02 TYPICAL WRI\G 8c IVOU\TI\G DETAILS A\D CALCULATIO \S FA -03 3UILDI\G 3 — NEW VEHICLE STORAGE FI ALAN PLA\ WIRE DESIGNATION SCHEDULE WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATI❑N SYMBOL DESCRIPTI❑N NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D ADDRESSABLE LOOP TWISTED -PAIR SHIELDED #16 FPLP RED (JACKET) S SIGNALING CIRCUIT TWO #14 FPLP RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 0.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BONG RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2" 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. SHIELDED WIRE TO BE GROUNDED AT P❑INT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END 1 DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 2. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS PERMISSIBLE 3. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 4. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT SUPPLIED BY SIEMENS CERBERUS DIVISION. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 6. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 7. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED DRAWINGS FOR "AS BUILT" PURPOSES. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT SHEETS AND/OR INSTALLATION INSTRUCTIONS. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. 10. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT OF 80" A.F.F. OR 6" BELOW DROPPED CEILING, WHICHEVER IS LESS. 11. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE ACTIVATION DEVICE. 12. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY GENERATOR. 13. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN—UP OF ALL TRADES IS COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN—UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 CHAPTER 7. 14. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACK BOXES OF DIFFERENT CIRCUITS. 15. ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO FINAL EQUIPMENT TRIM. 16. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. 17. THE ELECTRICAL CONTRACTOR SHALL CLEAN' ALL DIRT AND DEBRIS FROM THE OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES AFTER COMPLETION OF THEIR INSTALLATION. 18. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH IT IS LOCATED. 19. NFPA 72 2007 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING PHYSICAL CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME CABLE ASSEMBLY (I.E., MULTI—CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. 20. NFPA 72 2007 A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 M (4 FT) WHERE THE CABLE IS INSTALLED QUANTITY 1 12 2 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM CONTROL PANEL MS92000D FIRELITE PROVIDED 66" A.F.F. TO TOP SMOKE DETECTOR SD350 (ADDRESSABLE—PHOTO) FIRELITE 4S BOX W/ 1 G RING CEILING HEAT DETECTOR (ADDRESSABLE) H350R FIRELITE 4S BOX W/ 1G RING CEILING MANUAL PULL 0 STATI O N BG-12LX FIRELITE 4S BOX W/ 1G RING 48" A.F.F. TO CENTER ED DUAL SYNC MODULE DSM— WHEELOCK 4S BOX 12/24-R VERIFY IN FIELD M FIRE ALARM HORN STROBE ZNS-MCW WHEELOCK 4S BOX —FR 80" A.F.F. TO BOTTOM FIRE ALARM STROBE (WEATHERPROOF) RSSWP— WHEELOCK 24MCWH—FR WPSBB—R VERIFY IN FIELD RwpFIRE ALARM BELL (WEATHERPROOF) MB -G10 WHEELOCK WBB—R —24—R VERIFY IN FIELD O JUNCTI❑N BOX F.B.O. F.B,❑. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A ;;: N/A N/A N/A F,B.❑ FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.D.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A. N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A. N/A Proprietary and Confidential, NOTICE completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. Copyright 2008 by Guardian T Without Comments As Noted In Red Per The Attached Letter z it,cc P4tz FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS CD w Ct DESCRIPTION SUBMITTED FOR APPROVAL w Q D 0 N 0 QQJ z H ?)00o W Cn F- ,17,<00,co (/) (>,-)0‹ o.cc� cc 5<� W WJE 0' CW/^, ao v / 23: T W_ W J Final acceptance is subject to field test and inspection by i nese plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is vubiect to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings atter this' date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. The Tukwila Fire, Prevention Bureau. a g By: 0700 0 CC 0 z UKWILA FIRE DEPARTM .i' f +',ease call: 575-440Z and give this job No. 00 and exact address for shuts o,)Wvn or restoration approves PAID JUL 3 T 2008 Tukwila Fire (.n/7D Security Systems, Inc. All Rights Res rvea SCALE: NOT TO SCALE DRAWN BY: J/GARCIA SIGNED BY: T.QUAALE DATE: 07/24/08 BACKROUND PLAN PROVIDED BY: PAGE&BEARD JOB NUMBER: SHEET FA -01 } 0 0000 0 �o EL El LI 00 0000 0000 000 000 000 0000CO 0 00 0 Q 0000 00 000000 00 00 00000 E • e' T [14-1 000 i 0 aaaana0a0a0 o 00000000000=0= o 0 0 0 aaaaaa 0 0 C:11:382.1 u u CD 132 oEn 0= JUNCTI❑N BOX MOUNTED ON CEILING SLAB n 0 0 0 0 JUNCTION BOX MOUNTED AGA CEILING SUPP NST ORT n slVl SMOKE/HEAT DETECTOR TO NEXT DEVICE - SUSPENDED ILLUMINATED CEILING SMOKE/HEAT DETECTOR MOUTING DETAILS HORN/STROBE R 0 ▪ 4S DEEP BOX u 0 W 0111N I FIRELITE MS92000D 0 1 CONTROL PANEL HEIGHT REQUIREMENTS HORN STROBE MANUAL PULL STATION 4° SQUARE DEEP BACK BOX WITH 1G TRIM RING ©48" TO PULL HEIGHT REQUIREMENTS MANUAL PULL STATION BC -1 2LX TYPICAL WIRING AND MOUNTING DETAILS IE Job Name: Panel Location: Date Performed: QTY. BATTERY SIZING CALCULATI❑N VALLEY VIEW SEWER DISTRICT FRCP BATTERY CALCULATI❑N 07-30-2008 DEVICE NAME - BLDG B VEHICLE STORAGE STD-BY(Amps) ALARM(Amps) 1 FIRELITE: MS9200 2 FIRELITE: BG12LX 12 HEAT: H350R 1 SMOKE: SD350 1 BELL: MB -G10 -24R 3 H/S: ZNS-30W 1 STR: RSSWP-135CD 1 SYNC: DSM 0. 0080 0, 0000 0. 0036 0. 0003 0, 0000 0, 0000 0. 0000 0, 0000 0, 1680 0, 0005. 0. 0780 0. 0065 0, 0300 0, 3210 0. 3000 0, 0380 Totals = 0, 0119 Stand -By Load = 0. 0119 Amps Alarm Load Stand -By Time = 24 Hrs, Alarm Time Stand -By = 0,29 Amp*Hrs. Total = Stand -By + Alarm = 0. 29 + 0, 08 = 0, 36 Amp*Hrs 0. 9420 = 0. 9420 Amps = 5/60 Hrs, Alarm = 0,08 Amp*Hrs Multiply by De -Rating Factor of 1. 25 ---> 0.36 ) 1, 25 MINIMUM "BATTERY SIZE 0, 46 Aripere*Hours * 0.46 N000( RECOMMENDED • MINIMUM BATTERY SIZE= 700 Ampere*Hours NE NE Job Name: Circuit: Date Performed: WORST CASE VOLTAGE DROP CALCULATI❑N N VALLEY VIEW SEWER DISTRICT - BLDG B VEHICLE STORAGE SIGNALING CIRCUIT S1 VOLTAGE DROP CALCULATI❑N 07-30-2008 1 BELL:` MB -G10 -24R at 0,0300 Amps 3 H/S: ZNS-30W at 0,1070 Amps 1 STR: RSSWP-135CD at 0,3000 Amps each each each 0.0300 Amps 0.3210 Amps 0.3000 Amps Circuit Length Circuit Load = Voltage Drop = Voltage Drop = Total = 0. 6510 Amps 102 Ft to End Wire Size = #14 AWG 0.6510 Amps Voltage = 24. 0 Volts (Ckt, Load) * (Ckt, Length) * 21,6 (Circular Mils) ) (Volts) ( 0, 6510 ) 102 ) 21. 6 C 4110 ) * ( 24, 0) Voltage Drop= 1,45% VOLTAGE DROP = 1,45% 100% NE 100% RELEASE/REVISIONS REV. BY: 0 3 0 DESCRIPTION SUBMITTED FOR APPROVAL DATE 07/24/08 / z 0 z d J 0o I— 1-- 0 224c0 LueQD r off} w QJE w � CO >- `w w J 'GALE: NOT TO SCALE DRAWN BY: D.GARCIA DESIGNED BY: T.QUAALE DATE: 07/24/08 BACKROUND PLAN PROVIDED BY: PAGE&BEARD SYSTEM CALCULATIONS Proprietary and Confidential, Copyright 2008 by Guardian Security Systems, Inc. All Rights. Reserved OB NUMBER: 1 SHEET FA -02 0 ------ ____ 0 11 S1-5 135cd wp EOL ,S1 4 . '--4" s 2'-- 4" 0.5. 2)' . . • - . • • • 11' F.E. F \ / (t.)061 , / • 0' D Dc <0 u.H. SEL UiAL DuuR V/ MOTOR OPERATOR' T'r°P. VE.Ri FY • • R. 0. 110" ------ 11' ( -7 \ 114' , rn1)11-) S1-3 30ca --------------- ------------ ------------- - ------ ---- ---±- ------- -- z / \. D I 11' 0, Z_ • ( D 03) ---- . ----- .• 6' U11 Di\G (kJ v S1-2 8'• COM 0 / \ /° t / i\\. / \ / \ 0 5 LORAG / \ / 11' 0. . 0 79' 27' 0 D 0 / EIXH FAN I RA\,t1.1 •>.)Ei-f: Mt.C1-1 DW(.3S \ 0 S1-1 • • ELEO PANELS -- PRO \ -- SEE EL[C DWG'S, (INC FOR MN -re ------- _ / \-• / , . / i 0,- _.„ _-- : p 6 ..,-----/ _ 1 , 3'-4., --- _OPE 3% UP ONE --- VERIFY COL CENTERLINE OFFSET FROM GRID ..• LINE CF EAVE ABV • LINE OF RIDGE •ABV • UE vELFLN\Iu vE.ri STORAGE -7---:-- / r°- ------ ---- P.O. GIRT --------- WARNING STRIPES TO BE PAINTED ALONG SLAB EDGE (:)VER 6" ABV GRADE ----------- 4"? CnNr [ _I . L BOLLARD, PAINTED SATE1 'YELLOW, TYP. CPT 1.70 ' N NORTH AI ARM Fl 3oc-ct..?SS 1743 IST AVE. SO., SEATTLE, WASHINGTON FAX (206) 628-4990 (206) 622-6545 LLJ RELEASE/REVISIONS REV. BY: I 0 m 0 DESCRIPTION SUBMITTED FOR APPROVAL DATE 07/24/08 2 <<<<< z 0 u_ w CC 0 (/) w 0 w z 0 z co ‘CALE: 1/4" = 1'0" DRAWN BY: D.GARCIA DESIGNED BY: T.QUAALE DATE:07/24/08 BACKROUND PLAN PROVIDED BY: PAGE&BEARD ..JOB NUMBER: SHEET Proprietary and Confidential, Copyright 2008 b Guardian Security Systems, Inc. All Rights Reserved FA --03 LI < •v U EXISTING CONCI(TE SLAB <i </ 4 <i NEW CONCRETE BETWEEN BUILDING • AND<EXISTING. SLAB O EIBATH H 135°�7 STORAGE AREA -OVERHEAD W 4SH 2F 0 Lj ti 12 Z2 Z2 4-F 000 4-F Q200° Z2 Z2 200° EOL. t -s EOL 20d) Z2 ❑H 2000 Z2 D Z22 Z1 F EOL n . ALL WALL -MOUNTED AUDIBLE & VISUAL SIGNALING APPLIANCES SHALL HAVE THEIR HEIGHTS ABOVE THE FINISHED FLOOR AT 90' TO BOTTOM, NFPA 72, 1996 EDITION, ALLOWS 80'-96' FOR VISUAL DEVICES <CH. 6-4.4) AND REQUIRES A MINIMUM OF 90' TO TOP FOR AUDIBLE DEVICES OR 6' FROM CEILING, WHICHEVER IS LOWER <CH. 6-3.5), FOR SLEEPING AREAS GREATER THAN 16' (LINEAR) VISIBLE NOTIFICATION SHALL BE WITHIN 16' OF PILLOW AND GREATER THAN OR EQUAL TO 24' FROM CEILING TO TOP OF LENS FOR 110cd CCH. 6-4.4.3.2) 2. ALL EQUIPIMENT SHALL BE U.L. AND C.S.F.M. LISTED. 3. ELECTRICAL CONTRACTOR SHALL FURNISH ACCESS PANELS TO AREAS THAT REQUIRE SERVICING, TROUBLE SHOOTING, ETC. 4. DO NOT DEVIATE FROM CONDUIT RUNS AS SHOWN ON FLOOR PLANS WITHOUT PRIOR APPROVAL FROM SYSTEM SUPPLIER (GUARDIAN SECURITY SYSTEMS, INC., TEL (206)622-6545). FACTORS SUCH AS EXCESSIVE VOLTAGE DROP, ADDITIONAL PARTS, ENGINEERING, ETC., THAT ARE A RESULT OF CONDUIT RUN DEVIATIONS SHALL BE THE SOLE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. 5. DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIR -FLOW, NOR CLOSER THAN 3 FEET<SOOnm) FROM AN AIR SUPPLY DIFFUSER. 6. ALL FAN SHUTDOWN FUNCTIONS, DAMPER CLOSURES, AND ASSOCIATED MECHANICAL SYSTEM FIRE ALARM INTERFACE SHALL BE BY MECHANICAL CONTRACTOR, 7. ALL DUCT SMOKE DETECTORS SHALL BE MOUNTED BY THE MECHANICAL CONTRACTOR. DUCT SMOKE DETECTORS EXPOSED TO THE WEATHER SHALL BE WEATHER PROTECTED` BY THE MECHANICAL CONTRACTOR, ALL AIR VELOCITY TESTING SHALL BE PERFORMED BY THE MECHANICAL CONTRACTOR, 8. ALL 120VAC POWER REQUIREMENTS FOR THE FIRE ALARM SYSTEM SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR AND SHALL MEET ALL REQUIREMENTS OF THE AUTHORITIES HAVING JURISDICTION, 9. ALL FIRE ALARM DEVICE BACKBOXES, FIRE ALARM TERMINAL CABINETS, GUTTERS, JUNCTION BOXES, AND ASSOCIATED CONDUITS SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. REFER TO FIRE ALARM SYMBOL LIST AND/OR MOUNTING DETAILS FOR ADDITIONAL INFORMATION, SYSTEM SUPPLIER PROVIDED BACKBOXES SHALL BE INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. 10. SMOKE DETECTOR TESTING SHALL BE ACCOMPLISHED WITH TEST MAGNETS AS PER THE MANUFACTURER'S INSTRUCTIONS. 11. ALL WIRING_ INITIATING DEVICES AND ANNUNCIATOR PANEL SHALL BE SUPERVISED TO THE PRINCIPAL POINT OF ANNUNCIATION. THE FIRE ALARM CONTROL PANEL TO SUPERVISE THE ANNUNCIATOR PANEL, ALL INITIATING AND INDICATING DEVICE 'CIRCUITS. 12, ALL WIRING SHALL BE CUT FOR IN AND OUT. WIRING SHALL NOT BE LOOPED THROUGH DEVICES. ALL SPLICED WIRE POSSESING SHIELDS SHALL HAVE SHIELDS SPLICED AND TAPED TO PREVENT GROUND FAULTS. 13. POINT AND COMMON ANNUNCIATION AND T -TAPPING (EXCEPT SLC LOOP) ARE PROHIBITED. 14. PROVIDE 3/4' CONDUIT FROM FIRE ALARM CONTROL PANEL TO TELEPHONE BACKBOARD. FOR OWNER PROVIDED CENTRAL STATION MONITORING. 15. THE ALARM SYSTEM SHALL HAVE AN AUDIBILITY OF NOT LESS THAN 15dB ABOVE AMBIENT AOISE LEVELS. TESTING SHALL BE ACCOMPLISHED WITH A dB METER. 16. ALL FLOW SWITCHES SHALL BE 2 WIRE WITH NON -ELECTRONIC RETARD TYPE SIMILAR TO THE SYSTEM SENSOR MODEL 'WFD SERIES' ONLY. 17. ALL DEVICES .IN THE ALARM SYSTEM SHALL BE COMPATIBLE AND INSTALLED PER MANUFACTURER'S SPECIFICATIONS, 18. SYSTEM SHALL BE FURNISHED AND INSTALLED BY A NESCO AFFILIATE AND AUTHORIZED NOTIFIER DISTRIBUTOR. 19. FIRE ALARM SYSTEM INSTALLATION COMPANY SHALL BE UL LISTED (UUJS). 20. INSTALLATION SHALL BE IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE, NEC AND CONTRACT DRAWINGS 21. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ 22, THE FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF G.S.S, TECHNICIANS 23. A SET OF INSTALLATION AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY G.S.S. FIELD TECHNICIANS QUANTITY 1 2 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FACP FIRE ALARM CONTROL PANEL SGL -2000 NOTIFIER PROVIDED 66" A.F.F. TO TOP 195° AREA HEAT DETECTOR HD -601 NOTIFIER 4S DEEP .00x WA CEILING 3-0 RUNG • AREA HEAT DETECTOR HD -602 NOTIFIER 4S DEEP = BOX W/ 3-0 RUNG CEIUNG 0 MANUAL PULL STATION BNG-1R NOTIFIER. 4S DEEP BOX W/ SINGLE GANG RING 48" A.F.F. TO CENTER 75 FIRE ALARM HORN/STROBE FIRE ALARM STROBE MT-24-IS-VFR WHEELOCK RSS-2475W WHEELOCK 4S DEEP BOX W/EXTENSION 4S DEEB BOX NO RING 80" A.F.F. TO BOTTOM 80" A.F.F. TO BOTTOM EXTERIOR STROBE WM3T WHEELOCK W.B.B. WEATHERPROOF 90" A.F.F. TO BOTTOM O EXTERIOR4VDC BELL MB -G10 -24R WHEELOCK W.B.B. 90" A.F.F. WEATHERPROOF TO BOTTOM 0 FIRE ALARM N/A JUNCTION BOX BY ELECTRICIAN 4S BOX U.D.N. VERIFY IN FIELD FATC FIRE ALARM N/A TERMINAL CABINET BY ELECTRICIAN 18 x 18 x 6 U.O.N, VERIFY IN FIELD A.F.F. ABOVE FINISHED N/A N/A FLOOR N/A N/A EOL END OF LINE N/A N/A RESISTOR N/A N/A EOLP END OF LINE N/A N/A POWER MODULE N/A N/A EX EXISTING DEVICE N/A- N/A N/A N/A F.B.O. FURNISHED BY N/A N/A OTHERS N/A N/A N/A APPLICABLE NOT N/A N/A N/A U.O.N. UNLESS. OTHERWISE N/A N/A NOTED N/A N/A Without Comments VL VERIFY LOCATION N/A N/A IN FIELD WiA As Noted In Rei/A ❑ Per The Attached Letter WP WEATHERPROOF N/A DEVICE N/A JUNCTION BOX MOUNTED ON CEILING SLAB SYMBOL LI TO NEXT TUKWILA FIRE DEPARTMENT Please call: 575.4407 and give this job No. CC� 5 HEAT DETECTOR and exact address for shut - clown or restoration approval. SUSPENDED ILLUMINATED CEILING T DETECTOR MOUNTNG These plans have been reviewed by The Tukwila Fire Prcvcntion Cures i fix cc; ifari ria , with cuz, city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted ards and ordinances. The responsibility for the may of do totally w;pit fi-sc dcu nc r. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date:. A\2 -50b By 5i Coal° Pt) 07-3 malmom 0) CVS a 1co - tn c V) 0 W ce W Ce DESCRIPTION 0 W x z RECIMERMENTS PIAL STATION - HORWSTROSE MD STROBE WIRE SCHEDULE AND CONDUIT FILL CHART WIR DEVICE WIRE DESIGNATI IIN AREA HEAT DETECTOR SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE F INITIATING CIRCUIT TWO #18 FPL RED (JACKET) S SIGNALING CIRCUIT TWO #14 FPL RED/BLACK CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE DIMENSIONS AREA TWO 600V #12 AWG THHN/THWN .244 0.D. .0467 TWO 600V #14 AWG THHN/THWN TWISTED .210 0.D. .0346 TWO CONDUCTOR 300V #18 AWG FPL TW CABLE .156 J.D. .0191 CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE CONDUIT FROM THE TABLE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM FILL DIMENSION FROM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF THE WIRE. CONDUIT SIZE MAXIMUM FILL 1/2" .12 SQUARE INCH 3/4" .21 SQUARE INCH 1" .34 SQUARE INCH 1-1/4" .60 SQUARE INCH 1-1/2" .82 SQUARE INCH 2 1.34 SQUARE INCH FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM N.E.C., CHP. 9, TABLE 4. WIR DEVICE MANUAL PULL STATION AREA HEAT DETECTOR 120VAC POWER FAILURE A C T I N N SOUND CONTROL PANEL TROUBLE BUZZER YEYE Y E S ACTIVATE RELAY (ALARM FORMONITORING ROTROUBLE) YES YES Y E S EXTERIOR BELL AND STROBE YES YES N ANNUNCIATE AT FIE (ALARMOR ORTROUBLE) YES Y E S Y E S ANNUNCIATE AT REMOTE FIOR ALARM ANNUNCIATOR (ALARM OR TROUBLE) YES YES Y E S VIS ALTE ALARMIBLE/ SIGNAL Y E S Y E S N SHUT DOWN ALL AIR HANDLING (HVAC) THROUGHOUT BUILDING YES YES N EI WON WIRING FAULT OR DEVICE TROUBLE ONLY SEQUENCE OF OPERATION BATTERY SIZING CALCULATION NE WWWWWWWWWWWWWWWWWWWWWWWWWWWAWWWWWWWW*WWW*WWWW*WWWWW*WWWWWW**** Job Name' VAL VUE SEWER DISTRICT Panel Loco.t on1 MAIN FIRE ALARM CONTROL PANEL Date Performed! 04-17-2000 QTY. DEVICE NAME STD -BY( Amps) ALARM( Amps) 1 2000' 1 20001 8 HEAT' 1 HEAT! 2 MOD_M' 1 BELL' 2 H/Su 1 STR' 1 STR' MP-AT24 SGL -2000 HD -602 HD -601 BNG-1 MB -G10 -24R MT -IS( 75) RSV 75CD) WM3T 0. 0210 0. 0540 0. 0000 0. 0000 0. 0004 0. 0000 0. 0000 0. 0000 0. 0000 0. 0400 0. 1080 0. 1200 0. 0150 0. 0004 0. 0300 0. 4960 0, 1400 0. 0880 Tota t s = 0. 0754 1. 0374 Stand -By Load = 0.0754 Amps Alarm Load = 1.0374 Amps Stand -By Time = 24 Hrs. Alarm TIme = 5/60 Hrs. Stand -By = 1.81 Amp*Hrs Alarm = 0.09 AMp*Hrs Total = Stand -By + Alarm = 1.81 + 0.09 = 1. 90 Amp*Hrs Mutt i p l y by De -Rat I ng Factor of 1. 25 ---> 1. 90 * 1. 25 = 2. 37 wwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww A MINIMUM BATTERY SIZE = 2.37 Ampere*Hours wwwwwwwwwwwwwwwwwwSIEIIBwwwwwwwwwwwwwwwwwwwwwwwwwwIIB WORST CASE VOLTAGE DROP CALCULATION 3K WWWWWWWWWWWWWWWWWWWWWWWWWWNEWWWNEWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW Job Namei C1rcu1t Date Performed: 1 BELL' 2 H/Sr 1 STRu 1 STR' VAL VUE SEWER DISTRICT NEW SIGNAL CIRCUIT 04-17-2000 MB -G10 -24R at NS -2475W at RSS(75CD) at WM3T at 0. 0300 Amps . each 0. 1640 Amps each = 0. 1400 Amps each = 0, 0880 Amps each = 0. 0300 Amps 0. 3280 Amps 0. 1400 Amps 0. 0880 Amps Circuit Length = 150 Ft to End CIrcuIt Load = 0.5860 Amps Voltage Drop = Voltage Drop = Tota l = 0. 5860 Amps Wire Size Voltage (Ckt. Load) * (Ckt. Length) A = #14 AWG. = 24. 0 Volts 21. 6 (Circular Mlls) * (Volts) ( 0. 5860 ) * ( 150 ) * 21. 6 ( 4110 ) * ( 24. 0) Voltage Drop = 1. 92% wwwwwwwwwwwwwwwwwwwwwwwwwww SYSTEM CALCULATION c NE VOLTAGE DROP = 1. 92% NE wwwwwwwwwwwwwwwwwwwwwwwwwww A 100% A 100% P@METE APR 18 2000 W Z O (CALE: 1/4* = 1 0 } LL. 0 >12 awl 1- F- 101CCWEm DRAWN BY: JJD DESIGNED BY: ERIK ISAACSON DATE: 4/11/00 L 31(364-4- \,OB NUMBER: 52375 .} ri s ht 2000 b • Guardian Securi S stems, Inc. All Ri his Reserved SHEET FA= 01 co