HomeMy WebLinkAboutPP - 3728 SOUTHCENTER BLVD - BOULEVARD TOWNHOMES - PERMITS AND PLANS3728 SOUTHCENTER BLVD ASSOCIATED PERMITS 16-S-053 D14-0276 44tri"444 CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION Site Address: 3728 Southcenter blvd. Boulevard townhomes lot 4 Tenant Name: New Tenant? ❑ - Yes El - No Property Owner's Name: Oryan HomPc Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Mike Hutchinson Day Telephone: 253-381-4456 King Co. Assessor's Tax No.: Suite Number: Floor: Company Name: Evergreen Fire Protection Mailing Address: PO BOX 998 Puyallup 98371 City State Zip E-mail Address: EvergreenfireproOmsn.com Fax Number: 253-252-7943 Valuation of Project (contractor's bid price): $ 4000.00 Scope of Work (please provide detailed information): new NFPA 13D fire sprinkler system PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced_ The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: kAA, Date: 3/18/2016 Print Name: Mike Hutchinson Day Telephone: 253-381-4456 Plan Permit App.doc 5/14/10 TFD FP Form 8 2 - INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit - 62 q /6 S-1,53 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: jpleix b /iotz-T( .may$ S.G. ,t✓A. Type of Inspection: ‘f) f i r' fri, F-f-z-- Address:A Suite #: 37-75( S L 871./13 Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: ,pal, -5& 9-� & ;2-79� , Lv � ✓,9Z r e).<7,(2-149- (� f,'�� S- sm e40 ate_ 474,e -4s Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Date: /7/I2,4lit Hrs.: Inspector: f $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /6- 3 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: IL° ik I R u ilj1.6P To....uJIA.ox(5 Type of Inspqction: C_e,t-t-er/ NA/ 4, Address: 2--2D Suite #: c 611",_, u,1) Contact Person: Special Instructions: Phone No.: proved per applicable codes. Corrections required prior to approval. COMMENTS: o IL- /LYPet) g- Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: [nspector: 114 , S o Date: to%. a -I f,b Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 DATE: 3/19/2016 C:\program files\HRS Systems\hhouse35\Boulevard townhomes duplex lower.r EVERGREEN FIRE PROTECTION, INC. 10509 64th AVENUE E PUYALLUP,WA 98373 RESIDENTIAL SPRINKLER SYSTEM HYDRAULICS CALCULATION REPORT FOR Boulevard townhomes lot 4 Tukwilla 3728 Southcenter blvd. Date: 3/19/2016 File No: Data File Name: Boulevard townhomes duplex lower.rdf SPRINKLER SPACING 256.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 16.0 ft. Min. Dist. Bet. Spklrs: 8.0 Max. Dist. Spklr. to Wall: 8.0 ft. SPRINKLER SPECIFICATIONS Mfr: Reliable Descr: RA0612 RFC43 F1 Conc .Pend.(16x16) K=4.30 Calculated K Factor for Arm -Overs & Drops: 1.0 ft. x 1.101 in. Drop: K=4.26 (Incl. 1 Tee) 0.0 ft. x 1.101 in. Arm -Over: K=4.25 (Incl. 1 Tee & 1 Ell) PIPE SPECIFICATIONS Type: CPVC S-40 HWC: 150 WATER SUPPLY Source: Public Test Date: By: Static: 60.0 psi Resid: 0.0 psi Flow: 0.0 gpm Public Main Size: 0 in Domestic Demand: 0.0 gpm at node number 0 SPRINKLER DEMAND No.Spkirs. Min Spklr. Press. Node Total Avail. Req'd Flowing Flow (psi) No. Flow Press. Press. 1 13.0 9.3 2 13.0 60.0 36.1 2 13.0 9.3 2 26.5 60.0 43.4 REVIEWING AUTHORITY City of Tukwilla gosrulatribleliVorri 'CSRTIIICATt or COMPSTRNCY FORT PI OTSCTION SPRINKLER SYSTSMS Michael D. Hutchinson 1166-0599.80 Level 2 Evergreen Fire Protection, Inc. E • Date )ATE: 3/19/2016 C:\program files\HRS Systems\hhouse35\Boulevard townhomes duplex lower.r RESULTS OF ANALYSIS PIPE & NODE DATA * FLOW ANALYSIS * 1 sprinkler flowing * 2 sprinklers flowing FIXD * * P # END LEN FIT. LOSS EL SP *DISCH FLOW PF PT *DISCH FLOW PF PT 3WC NOD DIA EQV.LN PUMP (FT) (K) *(GPM) FL/FT PE (PSI) * (GPM) FL/FT PE (PSI) * 1 1 10.00 B ---- 30.0 4.26 ---- 0.0 0.00 10.5 13.5 -13.5 0.49 10.0 150 3 1.101 5.0 ---- 30.0 ---- ---- 0.00 0.00 10.5 ---- -0.03 0.00 10.5 2 2 23.00 150 3 1.101 3 3 20.00 150 4 1.101 4 4 17.00 150 5 1.101 5 5 10.00 150 6 1.101 6 6 1.00 150 7 1.101 3B ---- 30.0 4.26 13.0 -13.0 1.16 9.3 13.0 -13.0 1.16 9.3 15.0 ---- 30.0 ---- ---- -0.03 0.00 10.5 ---- -0.03 0.00 10.5 BR ---- 30.0 ---- ---- -13.0 0.80 10.5 ---- -26.5 6.0 ---- 10.0 ---- ---- -0.03 8.67 19.9 ---- -0.11 LBR ---- 10.0 ---- ---- -13.0 0.86 19.9 ---- -26.5 11.0 ---- 10.0 ---- ---- -0.03 0.00 20.8 ---- -0.11 3R ---- 10.0 ---- ---- -13.0 0.40 20.8 ---- -26.5 3.0 ---- 0.0 ---- ---- -0.03 4.33 25.5 ---- -0.11 -5.0 0.0 ---- 7 7 80.00 4L ---- 150 8 1.598 28.0 ---- 8 8 1.00 150 9 1.101 -5.0 0.0 ---- 0.0 ---- ---- -13.0 0.03 25.5 ---- -26.5 0.0 ---- ---- -0.03 0.00 30.6 ---- -0.11 0.0 ---- ---- -13.0 0.54 30.6 ---- -26.5 0.0 ---- ---- 0.00 0.00 31.1 ---- -0.02 0.0 ---- ---- -13.0 0.03 31.1 ---- -26.4 0.0 SRCE ---- -0.03 0.00 36.1 ---- -0.11 Legend: P - Pipe # DIA - Pipe Diameter EQV. LN - Pipe Equivalent Length PUMP - Pump Pressure SP - K -Factor FLOW - Flow Rate PF - Pressure Loss due to Friction PT - Total Pressure at Node Node Notes Pipe Notes LEN - Pipe Length FIT. - Pipe Fittings FIXD LOSS - Fixed Loss Device EL - Node Elevation DISCH - Discharge in gpm FL/FT - Friction Loss per PE - Pressure Loss due to 2.97 10.5 8.67 22.1 3.20 22.1 0.00 25.3 1.48 25.3 4.33 31.1 0.11 31.1 0.00 36.2 2.01 36.2 0.00 38.2 0.11 38.2 0.00 43.4 Foot Elevation Fitting Code Letters: E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, S=SwgChk, G=GatV1v, X= X, Y= )ATE: 3/19/2016 C:\program files\HRS Systems\hhouse35\Boulevard townhomes duplex lower.r The maximum velocity of water flow occurs in pipe 8 at 4.39 ft/s with 1 sprinkler flowing. The maximum velocity of water flow occurs in pipe 5 at 8.92 ft/s with 2 sprinklers flowing. ?IPE FITTINGS TABLE ?ipe Table Name: standard.npt 'AGE: C MATERIAL: CPVC S-40 HWC: 150 )iameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatV1v X Y Z L.101 1.00 5.00 5.00 1.00 1.00 8.00 2.00 0.00 0.00 0.00 L.598 2.00 7.00 8.00 1.00 1.00 14.00 3.00 0.00 0.00 0.00 Sprinkler system has been hydraulically calculated with the HASS HOUSE 3.5 computer program (License No. R609099990) to provide an average imbalance of 0.010 gpm at each node and a maximum imbalance of 0.05 gpm with one sprinkler flowing, and 0.010 gpm at each node and maximum imbalance of 0.06 gpm with 2 sprinklers flowing in accordance with NFPA 13 and 13D or 13R. The minimum source pressure is 20.0 psi with a minimum required pressure of 43.4 psi and a 7 minute flow of 185 gal. and a 10 minute flow of 264.6 gallons The minimum pressure at any node is 9.3 psi at node 2. HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 ATE: 3/19/2016 C:\program files\HRS Systems\hhouse35\Boulevard townhomes duplex lower P R E S S U R E P S I 60.0 1 54.0 48.0 1 42.0 36.0 30.0 24.0 18.0 12.0 6.0 0.0 CA WATER SUPPLY CURVE CC CD 04 8 12 16 20 24 Static 28 32 36 FLOW (GPM) = 60.0 psi (fixed pressure) (1 sprinkler flowing) A = Available Water Supply 60.0 psi @ 13.0 gpm B = Required Water Supply 36.1 psi @ 13.0 gpm (2 sprinklers flowing) C = Available Water Supply 60.0 psi @ 26.5 gpm D = Required Water Supply 43.4 psi @ 26.5 gpm 40 • 1 UNIT ADDRESS LOT 5 LOWER FLOOR 3726 SOUTHCENTER BOULEVARD ; = • r••••';';'1"iit.:E.3?••?;C:I);;k.' • 1 ' • •4;" : • •;V . 1- ••••;,••• • ! : —0v*, • ,-r.1::•••• General Notes 1. OWNER TO PROVIDE ADEQUATE HEAT (40T. MIN) TOPREVENT SPRINKLER PIPES FROM FREEZING. 2. OWNER TO PROVIDE HARD WIRED HOME SMOKE DETECTION SYSTEM. 3. CPVC PIPE SHALL HAVE HANGERS 6'-0" o\c AND NOT MORE THAN 6"'FROM ANY SPRINKLER HEAD. 4. ALL ATTIC PIPING TO BE TENTED WITH BATT INSULATION TO PREVENT FREEZING. 5. ALL' PIPING. TO BE 1" C.P.V.C. U.N.O. 6. A 6" BELL TO BE LOCATED ON THE EXTERIOR !APPROACH TO HOME IF REQUIRES BY THE LOCAL A.H.J. ' 7. IF A OUTLET FOR A FUEL FIRED APPUANCE lS, PIPED ON AN EXTERIOR COVERED DECK k INTERMEDIATE TEMP. DRY SPRINKLER WILL BE INSTALLED, 7:76 kbjlajok • . • •. • . • 4.14 4 •.• •••st ...•••• • . • / • •••• ause,it's • ;•04....4.4!'11,;;;r2xid • Scale 1' 0" LI* , 1.1'17 Sprinkler Syrnbol Legend L , SYM SPRINKLER ORIFICE SIZE, TYPE & FINISH QUAN TEMP IK FACTOR 0 RELIABLE RFC 43 16'x16' 2 head flow requirement 26 GPM 0 9.6 psi V-1 155" 4.9 RELIABLE Fl RES 49 16'x16' FLOW REQUIREMENT 26 GPM ist' 9.6 psi155 ' 4.3 V RELIABLE Fl RES 44 SIDEWALL 16' X 20' ,2,,_ 155' 4.3 VICTAULIC DRY UPRIGHT 200' 5,6 Reliable F 3 QR DRY Sidewall . 155' 5.6 TOTAL % q UNIT ADDRESS LOT 3 LOWER FLOOR 3730 SOUTHCENTER BOULEVARD UNIT ADDRESS LOT 2 LOWER FLOOR 3732 SOUTHCENTER BOULEVARD UNIT ACDRESS LOT 1 LOWER FLOOR 3734 SOUTHCENTER BOULEVARD DATE: 1/22/2016 EVEGREEN FIRE PROTECTI PO BOX 998 Puyallup, WA 98371. EVERGFP967LZ Phone: (253) 252-7942 REV: DRAWN: MH STATIC ,WATER FdSSURE 60 pal TO '7_SYSTEM PRESSURE GAUGE DRAIN VALVE DRAIN PIPED TO EXTERIOR AMES 20008 BACKFLOW PREVENTER 1.5" 1 b SIT'RINKLER. RISER 11 1" WATER METER ALL PIPE TO BE 1"CPVC. UNLESS OTHERWISE NOTED.- I. • ,• INSULATION • • . , • . J. • I • !. : 1 INSULATION 'TENTING DETAIL INC • • Sheet Title oulevarc • • *Ai • ••• 4 •i " 10 4ft, Pjf; tlag Without Comments. As Noted in Red • . Per The Attached Letter • •Th.: --)se plans have been reviewed by The tukwila. Fire : Prever4on Bureau fi:.if (nnforipance with current City andarlds. Acce.pum....e.: ,:.. subject to errors and cylissid,nsiwilich o:.1! -,:,i, .,;;;.,Tori7e violations of adopted tnclaticisland orttr71.1(..,:s.c:„ The resporis101ity for the adiNuacy pf designp,?•'..,2, :•iiiall‘,,. with the designer, Additiohdeletioils .;7.4• ,.7;::...rions to these drawings after this date hilli vdd thi•.: i.,.ecilptailet.-., and will require a. rdsubnlittal of tzvi7;;-:: ,,:',r›./,.c.,q. subsequent approval. , I • Final .aCceptance is subject to field test and Inspection by .The Tukwila Fire Prevention Bu eau. .. • • Date: ‘‘t -i 1 k By: (If tkiP 01/. N5t- bilAfro irete,A4 fts'r ret.'0441- : Tiii<VV:a„A FIRE DF.iPARTMENT caro.f2.05-575-1407 and:. give this Fire Permit No. os --3 7aeramosarsaa1NR and exact address for shut down or re4orgion approval. 6.5.3 A waming sign, with minimum V: inch letters, shall be affixed adjacent to the main shutoff valve and shall state the following: WARNING: The water system for this home supplies fire sprinklers that require certain flows and pressures to fight a fire. Devices that restrict the flow or decrease the pressure or automatically shut off the water to the fire sprinkler system, such as water softeners, filtration systems, and automatic shut- off valves, shall not be added to this system without a review of the fire sprinkler system by a fire protection specialist. Do not remove this sign. ff?Alp 21 2016 TUKVVI FIRE I • ) I! • Stamp . : • ANAtungilOniVinair""w""="3 •• • CERTIFICATE OF coMpItTENCY FIRE PROTECTION SPRINKLER SYSTEMS Michael D. Hutchinson 1166 -0599 -BO Level 2 • Evergreen Fire Protection, inc. EV tiGFP967 Sign Onto D FERE PLA\ Townhomes LOT Job Title outhcenter oulevard TukTfIa, Wo. UNIT ADDRESS . LOT 5 UPPER FLOOR 3726 SOUTHCENTER POULEVARD Y . re • • .t 4444. 4444.44rtummi zmusimmuouzlieV .1/41E41 i•; • MEM '. '�1•ltJ `•I • . •. • e. w�•-• •.w.y.tryr, • -.s.;•trr f�"..ek!.!.'-.+MMii.+n.;•r.'r... . . .d .*..w... • M i . T•.. . • U wo° tend UNIT ADDRESS LOT 5 MIDDLE FLOOR 3726 SOU TH CE ,. TER BOULEVARD UNIT ADDRESS LOT 3 — UPPER FLOOR 3730 SOUTHCENTER BOULEVARD UNIT ADDRESS LOT 2 UPPER FLOOR 3732 SOUTHCENTER BOULEVARD UNIT ADDRESS LOT 1 UPPER FLOOR 3734 SOUTHCENTER BOULEVARD 11"°rot ';. 4.0.14 ' t�11.0 I ' • ti • :1 ra- • UNIT ADDRESS • LOT 2 .a , T Miq • 373 )LE FLOOR TH#C N TER ,Ii T•r;it Mill i. 1 is 'Iii ; !AI • UNIT 4DDIESS :LOTS MIDPLLQR .3734 SOUTHCENTER BOULEVARD MUM Mut -• • E 111M, . :i. s••.weore• itkaifA., 3728 SOUTHCENTER BOULEVARD General Notes Sprinkler Symbol Legend 1. OWNER TO PROVIDE ADEQUATE HEAT (40r. MIN) TO PREVENT ' SPRINKLER PIPES FROM FREEZING. 2. OWNER TO PROVIDE HARD WIRED HOME SMOKE DETECTION SYSTEM. 3. CPVC PIPE SHALL HAVE HANGERS 6'—D" c\c AND NOT MORE THAN 6" FROM ANY SPRINKLER HEAD. - 4. ALL ATTIC PIPING TO BE TENTED WITH BATT INSULATION TO PREVENT FREEZING. 5. ALL PIPING TO BE 1" C.P.V.C. U.N.O. SYM SPRINKLER ORIFICE SIZE, TYPE & FINISH QUAN TEMP K FACTOR 0REUABLE RFC 43 16'x16' 2 head flow requirement 26 GPM CO 9.6 psi v-7 155' 4.9 ' . RELIABLE F1 RES 49 16'x16' FLOW REQUIREMENT 26 GPM CSA 9.6 psi 155' 4.3 / VRELIABLE F1 RES 44 SIDEWALL 16' X 20' .-2_155' 4,3 VICTAULIC DRY UPRIGHT200' 5.6 ' 6. A 6" BELL TO BE LOCATED ON THE EXTERIOR APPROACH TO HOME IF • REQUIRES BY THE LOCAL A.H.J., Reliable F 3 QR DRY Sidewall 155' 5.6 7. IF A OUTLET FOR A FUEL FIRED APPLIANCE IS PIPED ON AN EXTERIOR ' ' COVERED DECK A INTERMEDIATE TEMP. DRY SPRINKLER : WILL BE INSTALLED. , TOTAL \ q Scale 8"=1 E.VEGEE\ FIDE PROTECTION 1 PO BOX 998 Puyallup, WA 98371 EVERGFP967LZ Phone: (253) 252-7942 C Sheet 'Title • Stamp ®arrmmm nrrr s ar rrr rr�orrrrrmp� WASN�Ni•'TON STATE CERTIFICATE OF COMPETENCY 'FIRE PROTECTION SPRINKLER SYSTEMS Michael D. Hutchinson !1166 -0599 -Bo Level 2 Evergreen Fire Protection, Inc. VEVtGF FP J PLA\ 3oulevarc :Town homes LOT 4 Job Title 7SoJthnterH oulevarc Tu`kwilla, Wa: