Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 3734 SOUTHCENTER BLVD - BOULEVARD TOWNHOMES - PERMITS AND PLANS
3734 SOUTHCENTER BLVD ASSOCIATED PERMITS 16-5-055 D14-0279 44ittlaNt SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 3734 Southcenter blvd. Suite Number. Floor: Boulevard townhomes lot 1 Tenant Name: New Tenant? ❑ - Yes [ - No Property Owner's Name: Oryan Homes Mailing Address: City State Zip CONTACT PEtRSON-if there are questions about the submittal. Name: Mike Hutchinson Day Telephone: 253-381-4456 Company Name: Evergreen Fire Protection Mailing Address: PO BOX 998 Puyallup 98371 City State Zip E-mail Address: Evergreenfireproomsn.com Fax Number: 253-252-7943 Valuation of Project (contractor's bid price): $ 4000.00 Scope of Work (please provide detailed information): new NFPA 13D fire sprinkler system PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 3/18/2016 Print Name: Mike Hutchinson Day Telephone: 253-381-4456 Plan Permit App.doc 5/14/10 TFD FP Form 8 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: NV 0 R7AA/lr(e4A/4_ Type of Inspecti Fire Alarm: Address'. Suite #: 57-34—�� gN8 Contact Person: Special Instructions: Phone No.: Approved per applicable codes. r7Corrections required prior to approval. COMMENTS: 5tell vt FiAA/ lyerrlf-t- �r t R„A,( rlppn�tJ Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Date: ' iti, h-7.-- Hrs.:/ $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit DAN- ?277 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:V 1// 70Pg0/4/1- Type of Insp Ci/.6(- ' n:I �/ /7P(/i) A-#1. Address: Suite #: 3.-2 3 Y S6 P/vd Contact P rson: Permits: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: ojdv 40 / Z %.,1,,,- ipSi r 2- //7-0^4 .1.1 (Api.al:e-el / ,t / al - . �-// .�/ 44. —©4 A11, Lew AiAi if / S``1,s or I14 -'/mc. Vav 4 ZckrA611 • 1/aj-e- D,'•,.g,1 - for4cr-, ' 73-1044;) 0, Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: /52., _ _1 4-1 Date: 3/in -7 Hrs.: 2.O $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 DATE: 3/19/2016 C:\program files\HRS Systems\hhouse35\Boulevard triplex lower.rdfPage 1 EVERGREEN FIRE PROTECTION, INC. 10509 64th AVENUE E PUYALLUP,WA 98373 RESIDENTIAL SPRINKLER SYSTEM FULL FLOW HYDRAULICS CALCULATION REPORT FOR Boulevard Townhomeslot 1 Tukwilla 3734 Southcenter blvd. Date: 3/19/2016 File No: Data File Name: Boulevard triplex lower.rdf SPRINKLER SPACING 256.0 sq. ft./spklr.(max) Max. Dist. Bet. Spklrs: 16.0 ft. Min. Dist. Bet. Spklrs: 8.0 Max. Dist. Spklr. to Wall: 8.0 ft. SPRINKLER SPECIFICATIONS Mfr: Reliable Descr: RA4612 RFC43 F1 Cone .Pend.(16x16) K=4.30 Calculated K Factor for Arm -Overs & Drops: 1.0 ft. x 1.101 in. Drop: K=4.26 (Incl. 1 Tee) 0.0 ft. x 1.101 in. Arm -Over: K=4.25 (Incl. 1 Tee & 1 Ell) PIPE SPECIFICATIONS Type: CPVC S-40 HWC: 150 WATER SUPPLY Source: Public Test Date: By: Static: 60.0 psi Resid: 0.0 psi Flow: 0.0 gpm Public Main Size: 0 in Domestic Demand: 0.0 gpm at node number 0 SPRINKLER DEMAND No.Spkirs. Min Spklr. Press. Node Total Avail. Tot F1. (gal) Flowing Flow (psi) No. Flow Press. 7 min. 10 min. 1 23.4 30.2 1 23.4 60.0 164 234 2 18.1 18.0 1 36.5 60.0 255 365 REVIEWING AUTHORITY City of Tukwilla r 'VSPsiiiitMii'i i►ir% aarnPIc*T or courR'TIINCY mai summation s.aNK.$A srstws Memel D. Hutchinson i 1166-059943G Level2 Evergreen Fire Protection, Inc. r�111 1 i - -Melia DATE: 3/19/2016 C:\program files\HRS Systems\hhouse35\Boulevard triplex lower.rdfPage 2 PIPE & NODE DATA P # END LEN FIT. HWC NOD DIA EQV.LN RESULTS OF ANALYSIS FIXD LOSS EL SP PUMP (FT) (K) * FLOW ANALYSIS * 1 sprinkler flowing * 2 sprinklers flowing * * *DISCH FLOW PF PT *DISCH FLOW PF PT * (GPM) FL/FT PE (PSI) * (GPM) FL/FT PE (PSI) * * 1 1 12.00 R ---- 20.0 4.26 23.4 -23.4 1.18 30.2 18.1 -18.1 0.73 18.0 150 2 1.101 1.0 ---- 20.0 4.26 ---- -0.09 0.00 31.4 18.4 -0.06 0.00 18.7 2 2 26.00 2LR ---- 20.0 4.26 ---- -23.4 3.37 31.4 18.4 -36.5 7.65 18.7 150 3 1.101 11.0 ---- 20.0 ---- ---- -0.09 0.00 34.7 ---- -0.21 0.00 26.3 3 3 10.00 L ---- 20.0 ---- ---- -23.4 1.36 34.7 ---- -36.5 3.10 26.3 150 4 1.101 5.0 ---- 10.0 ---- ---- -0.09 4.33 40.4 ---- -0.21 4.33 33.8 4 4 12.00 2L3R ---- 10.0 ---- ---- -23.4 2.27 40.4 ---- -36.5 5.17 33.8 150 5 1.101 13.0 ---- 10.0 ---- ---- -0.09 0.00 42.7 ---- -0.21 0.00 38.9 5 5 10.00 3R ---- 10.0 ---- ---- -23.4 1.18 42.7 ---- -36.5 2.69 38.9 150 6 1.101 3.0 ---- 0.0 ---- ---- -0.09 4.33 48.2 ---- -0.21 4.33 45.9 6 6 1.00 150 7 1.101 -5.0 0.0 ---- 7 7 80.00 4L ---- 150 8 1.598 28.0 ---- 8 8 1.00 150 9 1.101 -5.0 0.0 ---- 0.0 ---- ---- -23.4 0.09 48.2 ---- -36.5 0.21 45.9 0.0 ---- ---- -0.09 0.00 53.3 ---- -0.21 0.00 51.2 0.0 ---- ---- -23.4 1.60 53.3 ---- -36.5 3.64 51.2 0.0 ---- ---- -0.01 0.00 54.9 ---- -0.03 0.00 54.8 0.0 ---- ---- -23.4 0.09 54.9 ---- -36.5 0.21 54.8 0.0 SRCE ---- -0.09 0.00 60.0 ---- -0.21 0.00 60.0 Legend: P - Pipe # DIA - Pipe Diameter EQV. LN - Pipe Equivalent Length PUMP - Pump Pressure SP - K -Factor FLOW - Flow Rate PF - Pressure Loss due to Friction PT - Total Pressure at Node Node Notes Pipe Notes LEN - Pipe Length FIT. - Pipe Fittings FIXD LOSS - Fixed Loss Device EL - Node Elevation DISCH - Discharge in gpm FL/FT - Friction Loss per Foot PE - Pressure Loss due to Elevation Fitting Code Letters: E=45 Ell, L=90 Ell, B=TeeBch, R=TeeRun, C=Couplg, S=SwgChk, G=GatV1v, X= X, Y= DATE: 3/19/2016 C:\program files\HRS Systems\hhouse35\Boulevard triplex lower.rdfPage 3 The maximum velocity of water flow occurs in pipe 6 at 7.89 ft/s with 1 sprinkler flowing. The maximum velocity of water flow occurs in pipe 6 at 12.29 ft/s with 2 sprinklers flowing. PIPE FITTINGS TABLE Pipe Table Name: standard.npt PAGE: C MATERIAL: CPVC S-40 HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E L B R C S G X Y Z 45 Ell 90 Ell TeeBch TeeRun Couplg SwgChk GatVly X Y Z 1.101 1.00 5.00 5.00 1.00 1.00 8.00 2.00 0.00 0.00 0.00 1.598 2.00 7.00 8.00 1.00 1.00 14.00 3.00 0.00 0.00 0.00 Sprinkler system has been hydraulically calculated with the HASS HOUSE 3.5 computer program (License No. R609099990) to provide an average imbalance of 0.010 gpm at each node and a maximum imbalance of 0.01 gpm with one sprinkler flowing, and 0.026 gpm at each node and maximum imbalance of 0.08 gpm with 2 sprinklers flowing in accordance with NFPA 13 and 13D or 13R. HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 DATE: 3/19/2016 C:\program files\HRS Systems\hhouse35\Boulevard triplex lower.rdfPage 4 P R E S S U R E P S I WATER SUPPLY CURVE 60.0 A C 54.0 1 48.0 1 42.0 36.0 1 30.0 1 24.0 1 18.0 1 12.0 6.0 0.0 04 8 12 16 20 24 28 32 36 40 FLOW (GPM) Static = 60.0 psi (fixed pressure) (1 sprinkler flowing) (2 sprinklers flowing) A = Available Water Supply C = Available Water Supply 60.0 psi @ 23.4 gpm 60.0 psi @ 36.5 gpm ;1; I i - UNIT ADDRESS• LOT 5 LOWER FLOOR 3726 SOUTHCENTER BOULEVARD UNIT ADDRESS LOT 4 LOWER FLOOR 3728 SOUTHCENTER BOULEVARD 'et , .177777,„,m140-• • ei etot • • „5•74717H1=w.r, trio 177:47'711:e4. • ••.... •••,. ••:- • —11-',:;•1•7:.•:',••:1••••=,.ta'-• 11'="e•=1"."""--7-:':;4412ki" •at.• 1 General Notes 1. OWNER TO PROVIDE ADEQUATE HEAT (407. MIN) TO PREVENT, SPRINKLER PIPES FROM FREEZING. 2. OWNER TO PROVIDE HARD WIRED HOME SMOKE DETECTION SYSTEM, 3. CPVC PIPE SHALL HAVE HANGERS 6'-O" '.c\c AND NOT MORE THAN 6" FROM ANY SPRINKLER HEAD. 4. ALL ATTIC PIPING TO BE TENTED WITH BATT INSULATION TO PREVENT FREEZING. 5. All PIPING TO BE 1" C.P,V.C. U.N.O. 6. A 6" BELL TO BE LOCATED ON 11-1E EXTERIOR APPROACH TO HOME IF REQUIRES BY THE LOCAL A.H.J. 7. IF A OUTLET FOR A FUEL FIRED APPLIANCE IS PIPED ON AN, EXTERIOR • COVERED DECK AINTERMEDIATE TEMP. DRY SPRINKLER WILL BE • INSTALLED. Scale SYM 1" 1' 8 Sprinkler Symbol Legend SPRINKLER ORIFICE SIZE, TYPE & FINISH QUAN UNIT ADDRESS LOT 3 LOWER FLOOR 3730 SOUTHCENTER BOULEVARD UNIT ADDRESS LOT 2 LOWER FLOOR 3732 SOUTHCENTER BOULEVARD 4$40•1;:ti!,,,,-.- • UNIT ADDRESS LOT 1• LOWER FLOOR 3734 SOUTHCENTER BOULEVARD TEMP K FACTOR RELIABLE RFC 43 16'x16' 2 head flow requirement 26 GPM 0 9.6 psi RELIABLE F1 RES 49 16'x16' FLOW REQUIREMENT 26 GPM 0 9.6 psi RELIABLE F1 RES 44 SIDEWALL 16' X 20' VICTAULIC DRY UPRIGHT Reliable F 3 QR DRY Sidewall TOTAL -s" 155' 155' 155' 200' 155' 4.9 4.3 4.3 5.6 5.6 ff; PRESSURE: GAUGE .•111111010111110111B 11 1 • . STATIC WATER PR.F.MURE 60 psi TO SYSTEM DRAIN VALVE — [RAIN PIPED TO EXTERIOR AMES. 2000B BACKFLOW PREVENTER 1.5" 80' 1" WATER METER SPRINKLER RISER NTS , • !.,4 ALL PIPE TO BE 1"CPVC UNLESS OTHERWISE NOTED. • • • EVEGEE\ FIRE PROTECTION PO BOX 998 Puyallup, WA 98371. EVERGFP967LZ Phone: (253) 252-7942 DATE:1/22/2015 REV: DRAWN: MH SHEET: ; • INSULATION .PIPE t ...•••••••••• INSULATIOft TENTING I ; • i• 0. • , ' r!, ; • r • Wtthott COmments . . As Noted in Red Per The Attached Letter j,• • The plans have been reviewed by The TukwilaFire Prevntion Buread i=or cdnforrnance With current city 5tandardS. Accdor is subject to errors and omissions which; do 3tithbrize violations of adopted :ndardS and rhe responsibility for the (,-iNpacy of destigt ntally with the designer. Additions, d.eletio'w.;,: to these drawings after this date will V6:10 :.:tei..,-fpice and will require a resubmittal of for subsequent aPprOval. . . . Final acceptance, is td field test and inSpectIOn by The Tukwila Fre Preveritii.Bureau. ' ; ! Date: By ( .t; ; '•• ' ( • ; • • 1 • • -X jfr,t)r,'.11:;-elo[cvs,4%- /6( F,loy(Lcixt-f)-i-el+ $11 -ruKvAult FIRE DPM piess6 calit206-575-44Q7 and this.rFite &-rmit No0 and exact address for shut.. • down or restorgion apr�v 1 OF1 Sheet Title tt, ;$ PAID T6W1114(:"V2 2L,A.1. 2;116 E , I !, • • ; Stamp IF INASETWOVSVATi "" "cm" "" CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Michael D. Hutchinson 1166 -0599 -BO Level 2 • Evergreen Fire Protection, Inc. EVE GFP 7 I Ste • oulevarc 0DLA\ TownhoMes •LT I Job Title thcenten Doulevarc Kwilic Wa. )2g UNIT ADDRESS LOT 5 UPPER FLOOR 3726 SOUTHCENTER POULEVARD UNIT ADDRESS LOT 5 MIDDLE FLOOR 3726 SOU TH CE:, TER BOULEVARD UNIT ADDRESS LOT 3 UPPER FLOOR UNIT ADDRESS LOT 1 UPPER FLOOR `��, �h }, , ■ -"' yrMaki ._ ,, Ross smma 111111110 111�rikw 3734 SOUTHCENTER BOULEVARD r G t) r" =11V3.1 1.11111111111111105)101611 Ikm 4'9 01747 e'. 2,0:,,Y+14,", 19.1k) UNIT ADDRESS LOT 4 MIDDLE FLOOR UNIT: ADDRESS LOT 4 UPPER FLOOR 3725 SOUTHCENTER BOULEVARD 3728 SOUTHCENTER BOULEVARD ffffff pp. RZERT�1 nota "�, ar .,....rr--m FIRE PROTI"4TION 6PRIHK .ER av Tems i' '■ Michael D. Hutchinson . 1166 -0599 -BG Level Evergreen Fire Protection, Inc. =V `' FP967 ■ a'g`mure General Notes Sprinkler Symbol Legend 1. OWNER TO PROVIDE ADEQUATE HEAT (407. MIN) TO PREVENT SPRINKLER PIPES FROM FREEZING. 2. OWNER TO PROVIDE HARD WIRED HOME SMOKE DETECTION SYSTEM. 3. CPVC PIPE SHALL HAVE HANGERS 6'—O" c\c AND NOT MORE THAN 6" FROM ANY SPRINKLER HEAD. ! 4. ALL ATTIC PIPING TO BE TENTED WITH BATT INSULATION TO PREVENT FREEZING: 5. ALL PIPING TO BE 1" C.P.V.C. U.N.O. 6. A 6" BELL TO BE LOCATED ON THE EXTERIOR APPROACH TO HOME IF REQUIRES BY THE LOCAL A.H.J.' 7. IF A OUTLET FOR A FUEL FIRED APPLIANCE IS PIPED ON AN EXTERIOR COVERED 'DECK A INTERMEDIATE TEMP. DRY SPRINKLER : WILL BE INSTALLED. SPRINKLER ORIFICE SIZE, TYPE & FINISH RELIABLE RFC 43 16'x16' 2 head flow requirement 26 GPM ® 9.6 psi RELIABLE F1 RES 49 16'x16' FLOW REQUIREMENT 26 GPM © 9.6 psi RELIABLE F1 RES 44 SIDEWALL 16' X 20' VICTAULIC DRY UPRIGHT Reliable F 3 QR DRY Sidewall TEMP K FACTOR 155' 4.9 155' 4.3 155' 4,3 200' 5.6 155' 5.6 EVERGEEN FIRE PQTECTION PO BOX 998 Puyallup, WA 98371 EVERGFP967LZ Phone: (253) 252-7942 heet.'.iTitle oulevarc TOTAL DRAWN: MH SHEET: 1 OF1