HomeMy WebLinkAboutPP - 16301 WEST VALLEY HWY - UNKNOWN - PERMITS AND PLANS16301 WEST VALLEY HWY
ASSOCIATED PERMITS
NONE
Lys 1)
•
t
f
t1►
F
//
t
1
\L
J,/ ,/
� R)
\
0
1
/.
/
/1/
/
0
i
'r
c
1
FIRE ALARM PANEL
-- 1
TOMON ITO� -F
(BYO -MEM
-
SITE PLAN
SCALE: I":: 30'
v
ZONE SCuED.
INITIATION
ZO N E
Z
3
5
7
a
9
10
11
12.
13
(4
15
1(o
t7
18
19
za
21
ALARM
ZONE BLDG,
2
3
9
5
(o
7
8
10
11
IZ
13
14
15
I (o
17
18
15
20
Zi
WIRE COLOR CODE
INITIATION (WATERF'LOW) M 13 THHN
ALARM (BELLS) *14
►►
LEGEND
1
_ 2
3
9
5
7
9
10
11
12
13
14
15
tb•
1?
18
tA!' AABAUAn'AU
C
G ATEIOU5E.
BROWN
ORANGE _
VIM I<
BLUE
DWG. SYm aot r TEM
0[6� ALARM BEI., ,. - 4"
* WATER FI QW SWITCH
BACKIUX
SPECIAL
S. GANG
itt FURNT INSTL. BY OTNE'AS- WIRE
4 CONNECTION BY LVS I .
M�INDtGQTEi PIPE Sac_
PVC PIPE-1JNDERGAJD - 3/4" EXCEPT AS NOTED
14
�-INDICATES NO. OF CONDUCTMS
ACCEPTED
WITHOUT COMMENTS.
AS NOTED IN RED
PER THE ATTACHED LETTER
The drawings affixed hereto have been
reviewed and accepted by the City of
Tukwila Fire Dept. Additions, deletions
or revisions to these drawings after this
date will void this acceptance and will
require a resubmittal of revised drawings.
ina acceptance is subject to field -
c ion by a representative of this
ent_, ,.
575-4407
/63o/ X, _
LTR. I DATE I REVISION
FIRE ALARM
SYSTEM
SCALE.
REL'D: 3-1-85
DATE:
28-85
APP'D:
SHT NO. 1 OF
4.1
r
T'(PICAL ALARM
ZONE
-`(P. UNIT PLAN (FIRST FLOOR)
10 K RES.
EOL
4. r RES.
T`1PICAL l NITI t T(ON Eos
ZONE
i
SCALE: A"z 11_Ou
ALARM
6 ELL
0
•
1/46
Lu
W
WATER SL. SW%
5
•6
RaZ-I
•5
rr1 C B -IDg
ANC -2_
f
ALAKM PANEL
O
IZO V AC
( Bi OTH ERS
ELEC DMa.
1
STD DTE MONITOR.
(13Y OTNERS�
A VAINEL
.i_5i A.F. F.)
1103 IDE
(SLI)
FLEX
WATEL FLOW
S
PYALL
n
J
re
SE COMO FLR r
F I NST FLR
LOFT
S.G. aox
EOL'
{
T'(P. UNIT KtSER DIAGRAM
L•B OR PULL DOX
7(FIC A L ELDG. DETA I L
G ATEN FUSE
RCM ENTRY
ALARM BELL
fi=t 1
120 VAC FKO V 10E 0 BY OT'MMERS
G ATEHOQISE
PYC P'Pr
r
ri
ABOVEd FLR.
ALARM Kt
IL'�
\1\11T PLAN- ttY RAZ
EQUIP, MOUNTING DET/\tLS
LTR. I DATE ` REVISION
PRORah ROCK RESIDENCE INN TUK.WCLA,WA
SYSTEM VIRE ALITPM
SCALE: .UOVVN
DWN: (M
REL'D: 3-1- 85
DATE: Z -Z$'85
APP'D:
[LvsI)
- i
DWG. NO4 5562
SHT NO. L
16301 WEST VALLEY HWY
ASSOCIATED PERMITS
NONE
EVI5IO1•1S APO P TAPS FOrz.5PAI5, ,&P EV EX 4' 6A51-1AIN 9-10-84 2_11W
KEVISE17 LAI3ANA, POOL, SPoXr OUT 4.Ar
_ MOYED 4 STALLS MOM 5/W PARKING LOT TOW -
OF GA-rEHOU5E, MOVEQ FH 13Y GATENOUSF_ W 9-13-84 DJt4
1
PELETEP 1:47CINI4 UN'ER 5TRANDE2 OLV12, ELO6ATEI2 514 FH ,
1;ELOCATE9 rETEZ5 P2V'5 Fog_ 6LPa5 i4 i6, 17,418, ApnED Nor55 10 -1q -8412.1I4
AI71PED 8". 4" TEE, 4'16V 42 LF 4" r7IP S (iLt?Lj4-8 FOR. SPI N IKLEZ 5F)
A7t7Ei? NOTE6 9,10, 4 11 1 I -27-84 PFJ W
K\C7it
0,14)fr
2.10 2 To
41,4%41
E1261 To
frt_f1__( ir'1/4k
10 TAPPING -TEE W/8" TAPPING VA NtE
ISS am BS
WM PRV
(BOX a COVER REQID)
NEW WATER MAIN & GATE VALVE W/LINE SIZE
6 GATE VALVE t
NEW FIRE HYDRANT ASSEMBLY, 8'3(8 'x 6" TEE,
BEND W/CONCRETE BLOCKING, MECHANICAL -JOINTS
(M..1) UNLESS NOTED
EXISTING WATER MAIN a GATE VALVE -
EXISTING WATER MAIN a FIRE HYDRANT
STREET SERVICE ,WATER METER, PRESSURE
REDUCING VALVE, BUILDING SERVICE
•
WATER SERVICE- --6A:FA-
BLDG.
CAB A
FIXTURE STREET SVC BLDG.
UNITS METER SVC _
62
102
36
PRES URE RANGE = 60+
UPC 1982 EDITION, TABLE 10-2, P. 83
1- PRv
IRRicIATIoN
CAP PLo6K 4H 171 P AT
VAULT LZAT1ON
SPRINKLER CoNTRAGTOR)
150( frq)
N-02
47-1
ZI
CX 6i,
Zt 61
THE SERV1G Es PW -11 THE PKVATE MAINS/FIRE LooF TO ANt2
PEPLIGTEP/I%.1LL2 .::=L-1=P.O.f7115 CONTeATOR,. TOAPF2-1- rog-
WATM MAINS
SHEET C-8
PETAL -it 4, 5HEEr C-7
TU4.WILA STANPAQ2 PETAL 14 5/10
II --I-15. FIRE PEPARTMENT 15 TO IX- CONTAGTEP TO WITNe55
.c31 5-rAtiVAI
1 17 81
Uri I
1
Cu
CO
ACCEPTED
WITHOUT COMMENTS
AS NOTED IN RED
ER THE ATTACHED LETTER
ukwila Fire Dept Additions del _rts
1 date will void this acceptance an ± ll
GATEHOUSE
WATEK
7112 35 c wAlt,e
5,0003 A
,tt-,\:;*0 %4 -0t -y*
ti11.0).5/t4 tOTV-6.1 PPUtOtril,%
5tr- Qt.TA1L q 55vkA C--7
WEST N A1.1 -EY HIGHW AY
r14 CIATE LEL--
F1L
o30
vegr
TO ObTAININci SEPARATE. PERMIT 13-r
WASH 5TATE. DEPT Of TRAN5PORTAT1ON
rIELP VERIFY LOCATION OF EXISTIN4
10' WATER MAIN INSTALL -NET TAP)
JohnsonBraund design group p.s. inc.
architectu
•
rr
AP AN
Lawrence S Braund, PE
Thomas A Johnson, A IA
cc
(206) 383-2000
01 0
01 CO
co 0
111 0
CI cn
CI SC I;
Ca*
CCI
co
Fri
CO
0
0
0
LO
1.0
0
CO
0)
0
0
0
(75
0
co
Latest rev ' it ~25-84
1
ngineering & planning consultants
',BID SET ONLY
i -THESE DRAWINGS ARE SUBJECT TO REVISIONS
1:7TI,NG